Loading...
HomeMy WebLinkAboutDWG 471-3SW; CT 10-01; BMP SITE PLAN - SEABREEZE VILLAS; 01' ' I \ -IJ i I I I I I I I I I I I \ I I I I \ I -,sJsD- sD: H I I I I I I I I I I .--,--: .fl . . . . · .. ,.,;--:i .. . --. •. I 11 11 ----- \ 1--- I \'IV GARFlELD---=-ST~-- LEGEND f:Z:'.1 LANDSCAPE AREAS 'MTH BMP's: (MAINTAINED BY PROPERTY OWNER/HOA) --••-TRACT BOUNDARY NAP NOT A PART -◄►► DIRECTION OF ONSITE SURFACE FLOW --t►► DIRECTION OF OFFSITE SURFACE FLOW ~ PERMEABLE CONC. PAYERS BMP ID# BMP TYPE SYMBOi.. TREATMENT CONTROL ® PERMEABLE ~ INTERLOCKING CONC. PA VERS MANF. BY UNI-ECOSTONE 0 BAFFLE BOX ■ LOW IMPACT DESIGN (L.I.D.) SOURCE CONTROL G) CATCH BASIN ■ STENCILING © FIL TIRA TION ~l © COMMON AREA ~l EFFICIENT \RR. © COMMON AREA W---/2l RUNOFF B~P TABLE CASQA NO. QUANTITY DliAWING NO SHEET NO.(S SD-20 2297 SF. D~G 471-3A 2 TC-40 2 EA. D~G 471-3A 2,3 SD-13 1 EA. 000 471-3A 2 SD-10 SD-12 SD-11 BLDG C INSPECTION FREQUENCY ONCE A YEAR 1-4 TIMES A YEAR ONCE EVERY THREE MONTHS ~n.l/ St.cir NAP BLDG A MAINTENANCE CONSTRUCTION FREQUENCY SIGN OFF PERIODIC CLEANING AND VACC\JM CLEANING THE SURFACE An.EAST ONCE A YEAR 1-4 TIMES A YEAR DETERMINED BY ACCUMULATION OF SEDIMENTS PERIODIC CLEANING ONCE EVERY THREE MONTHS ~rit.~.\ stal'r NAP SWMP NO. CT-10-01 (SWMP 11-02) MAINTENANCE AGREEMENT DOCUMENT: RECORDATION NO. ___ _ 1 [5] 6 YES ./ PARlY RESPONSIBLE FOR MAINTENANCE: NAME: TMS DE\1£1 OPMENT LLC, CONTACT: TONY SFREDDO ADDRESS: 32 SYLVAN IRYJNE, CA 92603 PHONE NO: 95]-80]-0888 PLAN PREPARED BY: NAME: SURENDER DEWAN COMPANY: DMS CONSULTANTS, INC, ADDRESS: 12371 LE'MS SL, SUITE 203 GARDEN GROVE, CA 92840 PHONE NO 714 7 40 8840 " --: ' ' . CERTIFICATION R C E 34559 SCALE: 1"=10' Ell II. a NO. 34559 9/30/ ENGINEER D1'1S CON~ULTANTS, INC. C I v,:,,L E N G I N E E R S 12J71 I.GIM Sl Ll.;lrd1111 QrQ>1 CA. 9~40 P, 71 'r740-S840 f, 714-7'10-6!142 DATE NO INITIAL I'~·-A· -3 ')P; IL ENGINEER OF WORK SURENDER M. DEW RCE5455 ~ 2 S37'29' 46"E 3 ~ ~-----~ --Jr-=-"~--r-e'~ :::.:_-:-' I= ~ fil-~,; =-==~j ··-,----= -' .. . : :, '"-..._ . ,:: ·.··,: . ' . ---------7 ' ' " " " I ii " " " ' ' '-- r - ' ' ' " .. " ii " I 90,21' -. ---- ~ cd --, 1-.--EXIST. WOOD FENCE w UNIT 8 t-"\Q 5!~..,l.-Q-x ' ' k=====~-~~~p-=··==~7' ~~/m I· . . GJ UNIT 7 ' " " " " X ~ I I <.!) z g 5 ID UNIT 6 rc:·C -"'t ~.~~--~==rr_i~=-~Jc==i· [~;[ (!) /1\ 4 J BMP ~OTES: 1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTIJRER'S RECOMMENDA llONS OR THESE PLANS, 2. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 3. NO SUBSTITIJTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES WlHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION ANO INSTALLATION, DATE INITIAL DATE INITIAL RE\JSION DESCRIPTION OTHER APPROVAL CITY APPROVAL I SH~ET I X I I \ \ \_..0- 1 I I I 1 VICINlfrr MAP VERIFIED BY: z I= V1 X w J..\ INSPECTOR DATE CITY OF CARLSBAD SHEETS ENGINEERING DEPARTMENT of 1 BMP SITE PLAN FOR: SEABREEZE VILLAS 391 TAMARACK AVE, CARLSBAD, CA. 92008 APPROVE~ Y. ~ JJ4. GLEN K. v;;.;;~KI CITY ENGINEE'.R PE 41204 EXPIRES 3/31/13 DA OWN BY: NC PROJECT NO. DRAWING NO. CHKD BY: RVWO BY: CT-10-01 471-3SI