HomeMy WebLinkAboutMS 2017-0003; CAZADERO DRIVE CONDOMINIUMS; FINAL SOILS REPORT; 2023-07-24 GEOTECHNICAL | ENVIRONMENTAL | MATERIAL July 6, 2023 Revised July 24, 2023 Project No. 3856-SD Cypress View Builders 401 B Street, Suite 2400 San Diego, California 92101 Attention: Mr. Ron Hiebert Subject: Final Soils Report of Geotechnical Observation and Testing 2812 & 2814 Cazadero Drive Carlsbad, California Dear Mr. Hiebert: We are pleased to present herein the results of our geotechnical observations and testing services during rough, precise, and post-grading construction associated with the subject project. This revised version of the report incorporates the City inspectors request to provide a plot plan of compaction tests for post grading, rough grading and a revised subject title. Rough and precise grading of the subject was completed under the observation of Hetherington Engineering, Inc. (Hetherington, 2019 and 2021). Post grading occurred between November 1, 2022 to June 6, 2023. It is to the best of our knowledge that site post-grading presented in this report has been completed in general accordance with the approved geotechnical reports for the site (Hetherington, 2018a and 2018b), geotechnical recommendations presented during construction, applicable provisions of the 2016 California Building Code (CBC) and City of Carlsbad guidelines. The subject site is geotechnically suitable for its designed use. Post-grading construction observation and testing included excavations for the residential buildings and retaining wall foundations, retaining wall backfill, sidewalk, driveway, and driveway approach subgrade. Offsite improvements consisted of trench backfill for water, sewer, and gas utility tie-ins, as well as structural pavement patchback and overlay (subgrade, aggregate base, and asphalt) along Cazadero Drive. This report provides a brief summary of site conditions observed during post grading construction for the subject site and offsite work. Also provided herein are field density and moisture content test results (compaction) and laboratory analysis. GeoTek, Inc. 1384 Poinsettia Avenue, Suite A Vista, CA 92081-8505 (760) 599-0509 Off, (760) 599-0593 Fa. www.geotekusa.com Cypress View Properties, Inc. July 24, 2023 Geotechnical Final Soil Report Project No. 3856-SD 2812 & 2814 Cazadero, Carlsbad, California Page 2 1. SUMMARY OF GEOLOGIC AND SOILS CONDITIONS 1.1. ROUGH AND PRECISE GRADING  Rough and precise grading observation and testing was performed under the observation and testing of Hetherington Engineering, Inc. A copy of their reports are provided herein as Attachment A. At the request of the City inspector, Hetherington’s geotechnical observations have been transferred onto GeoTek’s Figure 1. 1.2. POST GRADING:  Visual classification of the soil in the field, compared to the soil description from laboratory testing, was the basis for determining the maximum dry density value and optimum moisture content applied to each soil density test. Laboratory results were supplied by a GeoTek laboratory or a product’s manufacturing supplier.  Trench backfills for the sewer, natural gas, and water lines were placed and compacted to at least 90% of the maximum dry density, at or slightly above optimum moisture content relative to ASTM D 1557.  Subgrade for the driveway approach, which includes monolithically poured curb and gutter improvements was compacted to at least 95% of the maximum dry density, near or slightly above optimum moisture content relative to ASTM D 1557.  Subgrade for sidewalk and driveway improvements were compacted to at least 90% of the maximum dry density, near or slightly above optimum moisture content relative to ASTM D 1557.  The upper foot (approximately) of subgrade for the offsite street improvements (utilities trenches) along Cazadero Drive associated with the project were compacted to at least 95% with above optimum moisture content relative to ASTM D 1557.  Aggregate base for the offsite street improvements (utilities trenches) along Cazadero Drive associated with the project were compacted to at least 95% and at or slightly above optimum moisture content relative to ASTM D 1557.  Asphalt-concrete (AC) for the offsite street improvements (utilities trenches and overlay) along Cazadero Drive associated with the project were compacted to at least 95% relative to ASTM D 2041. GEOTEK Cypress View Properties, Inc. July 24, 2023 Geotechnical Final Soil Report Project No. 3856-SD 2812 & 2814 Cazadero, Carlsbad, California Page 3 2. FIELD AND LABORATORY TESTING 2.1 FIELD TESTING Field density tests were taken at periodic intervals and random locations to check the compaction efforts by the grading and wall contractors. The field density testing for the subject site was performed using a nuclear gauge, in general accordance with testing procedure ASTM D 6938 for soils and ASTM D 2950 for asphalt concrete. The results of the field density testing conducted for the herein reported site area are included in Tables 1 through 6. 2.2 LABORATORY TESTING The laboratory maximum dry density and optimum moisture content for the soils were determined in general accordance with test method ASTM D 1557. The laboratory maximum density for asphalt was provided by the material facility. The table below presents the soil types used for this project. 2.3 CONCLUSIONS Field density tests indicate that the fill materials were compacted to the project specifications at the time and locations tested. Where compaction tests showed a value less than project minimums relative to the laboratory standard, the area was subjected to additional work and SUMMARY OF LABORATORY MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT TEST RESULTS (ASTM D 1557/2041) Soil Type Description Total Density (pcf) Maximum Dry Density (pcf) Optimum Moisture Content (%) A Light Olive Brown Silty Clayey Sand - 119.0 12.0 B Class II Crushed Miscellaneous Base - 114.9 9 13.0 C Class II Crushed Miscellaneous Base - 122.0 12.0 HE-2 Crushed Miscellaneous Base - 127.0 10.0 AC-1 Asphalt - Plant Provided 145.5 - - AC-2 Asphalt - Plant Provided 146.1 - - GEOTEK Cypress View Properties, Inc. July 24, 2023 Geotechnical Final Soil Report Project No. 3856-SD 2812 & 2814 Cazadero, Carlsbad, California Page 4 retested to verify minimum project compaction specifications were achieved. It is our professional opinion that the subject project is suitable from a geotechnical standpoint. 3 LIMITATIONS The purpose of this report is to present a summary of observation and testing services provided by this firm during the post-grading operations that were performed on the subject property between November 1, 2022 to June 6, 2023. More specifically, the scope of this report includes a presentation of data obtained during rough and post-grading and a discussion of operations performed by the contractors. Preparation for, and placement of, compacted fill was monitored by representatives of this firm. All soils and asphalt tested were found to meet or exceed the minimum degree of compaction specified in the job requirements. Field density tests were performed at random locations throughout the area of the job that is within the scope of this report. Our observations and testing were performed in such a manner as to be reasonably certain that the soils and asphalt tested are representative of the work, and that the work, in general, essentially complies with the job requirements. Our services were performed in accordance with engineering principles generally accepted at this time and in this area. No warranty is expressed or implied. It should be understood that field data, including density test locations and elevations, as well as the location of compacted fill, are only approximately noted. The accuracy of our field technician's estimated locations will vary depending on the survey control available at the time the estimations were made. This report is subject to review and approval by the controlling authorities for this project. GeoTek accepts neither responsibility nor liability for work, testing, or recommendations performed or provided by others. GEOTEK Cypress View Properties, Inc. July 24, 2023 Geotechnical Final Soil Report Project No. 3856-SD 2812 & 2814 Cazadero, Carlsbad, California Page 5 We appreciate the opportunity to be of service on this project. Please contact the undersigned if you have any questions. Respectfully submitted, GeoTek, Inc. Christopher D. Livesey Edwin R. Cunningham CEG 2733, Exp. 05/31/25 RCE 81687, Exp. 3/31/24 Vice President Project Engineer Enclosures: Figure 1 – Field Density Test Location Map Table 1 – Summary of Sewer Field Density Tests Table 2 – Summary of Water Field Density Tests Table 3 – Summary of Subgrade Field Density Tests Table 4 – Summary of Aggregate Base Field Density Tests Table 5 – Summary of Asphalt Field Density Tests Attachments: Attachment A – As-Graded Geotechnical Report, Hetherington Engineering, Inc. Attachment B – Update As-Graded Geotechnical Report, Hetherington Engineering, Inc. Distribution: (1) Addressee GEOTEK Cypress View Properties, Inc. July 24, 2023 Geotechnical Final Soil Report Project No. 3856-SD 2812 & 2814 Cazadero, Carlsbad, California Page 6 REFERENCES Hetherington Engineering, Inc., 2018a, “Geotechnical Investigation, Proposed Residential Duplex, Lot 357, La Costa Meadows Unit No. 2, Cazadero Drive, Carlsbad, California,” Project No. 8479.1, Log No. 19987, dated July 31, 2018. _____, 2018b, “Grading Plan Review/Response to City Review Comments, Proposed Residential Duplex, Cazadero Drive, Carlsbad, California,” Project No. 8479.1, Log No. 20177, dated November 26, 2018. _____, 2019, “As-Graded Geotechnical Report, Residential Duplex, 2812 – 2814 Cazadero Drive, Carlsbad, California,” Project No. 8479.2, Log No. 20795, dated December 16, 2019. _____, 2021, “Updated As-Graded Geotechnical Report, Residential Duplex, 2812 – 2814 Cazadero Drive, Carlsbad, California,” Project No. 8479.2, Log No. 21379, dated April 8, 2021. Christiansen Engineering & Surveying, 2021, “Grading Plans for Cazadero Drive Condo Project, Carlsbad CA 92009” Sheets 1 through 7, Grading Drawing No. 513-5A, JN 208512 Approved date of August 6, 2019. GEOTEK Figure 1 Field Density Test Location Map Rincon Homes 2812 & 2814 Cazadero Carlsbad, California GeoTek Project No. 3856-SD RW-1 RW-2 RW-3 SS-1 SS-2 SS-3 SS-4 W-1 W-2 W-3 W-4 SG-1 SG-2 SG-3 SG-4 SG-5 SG-6 SG-7 SG-9 SG-8 SG-10 SG-11 SG-12 SG-13 SG-14 AB-1 AB-2 AB-3 AB-4 AB-5 AB-6 AB-7 AB-8 AC-1 AC-2 AC-3 AC-4 AC-6 AC-5 AC-7 AC-8 AC-9 AC-10 AC-11 AC-12 LEGEND APPROXIMATE LOCATION OF ENGINEERED FILL TEST APPROXIMATE LOCATION OF RETAINING WALL TEST APPROXIMATE LOCATION OF SEWER TEST APPROXIMATE LOCATION OF WATER TEST APPROXIMATE LOCATION OF SUBGRADE TEST APPROXIMATE LOCATION OF AGGREGATE BASE TEST APPROXIMATE LOCATION OF ASPHALT TEST 29 29 28 27 2625 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 RW-3 SS-4 W-4 SG-13 AB-8 AC-12 0 D D I D 0 I SCALE: 1" = 10' "' D D GEOTEK CYPRESS VIEW BUILDERS 2812 2814 Cazadero Drive Carlsbad, CA GeoTek, Inc. Sewer 7/6/2023 Project No.: 3856-SD DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 3/6/23 1 2812 Cazadero Dr. - in front -2' 13.4 113.8 A 119.0 N 96 2 2812 Cazadero Dr. - in front -1' 12.8 114.5 A 119.0 N 96 3 2812 Cazadero Dr. - in front SG 14.2 113.6 A 119.0 N 95 4 2812 Cazadero Dr. - in front SG 12.9 115.2 A 119.0 N 97 TABLE 1 SUMMARY OF FIELD DENSITY TESTS Sewer Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate CYPRESS VIEW BUILDERS 2812 2814 Cazadero Drive Carlsbad, CA GeoTek, Inc. Water 7/6/2023 Project No.: 3856-SD DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 2/15/23 1 2812 Cazadero Dr. - in front -2' 11.3 117.2 A 119.0 N 98 2 2812 Cazadero Dr. - in front -1' 10.9 116.9 A 119.0 N 98 3 2812 Cazadero Dr. - in front SG 12.5 116.4 A 119.0 N 98 4 2812 Cazadero Dr. - in front SG 12.1 118.6 A 119.0 N 99 TABLE 2 SUMMARY OF FIELD DENSITY TESTS Water Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate CYPRESS VIEW BUILDERS 2812 2814 Cazadero Dr Carlsbad, CA GeoTek, Inc. Subgrade 7/6/2023 Project No.: 3856-SD DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 5/10/23 1 Southbound Trench to East Prop.SG 10.2 126.5 HE-2 127.0 N 99 2 Southbound Trench to East Prop.SG 9.2 121.2 HE-2 127.0 N 95 3 Southbound Trench to East Prop.SG 9.4 124.2 HE-2 127.0 N 98 5/11/23 4 Northbound adj to East Prop.SG 11.2 122.5 HE-2 127.0 N 96 5 Northbound adj to East Prop.SG 10.2 121.4 HE-2 127.0 N 96 6 Northbound adj to East Prop.SG 12.1 123.8 HE-2 127.0 N 97 5/12/23 7 Northbound adj to West Prop.SG 12.4 125.5 HE-2 127.0 N 99 8 Northbound adj to West Prop.SG 11.8 126.4 HE-2 127.0 N 99 9 Northbound adj to West Prop.SG 12.6 123.8 HE-2 127.0 N 97 5/16/23 10 Sidewalk Northbound SG 14.3 116.3 HE-2 127.0 N 92 11 Sidewalk Northbound SG 13.4 115.7 HE-2 127.0 N 91 12 Sidewalk Northbound SG 15.5 119.3 HE-2 127.0 N 94 6/6/23 13 2812 Cazadro Driveway SG 16.8 110.8 A 119.0 N 93 14 2814 Cazadro Driveway SG 13.1 115.7 A 119.0 N 97 TABLE 3 SUMMARY OF FIELD DENSITY TESTS Subgrade Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate CYPRESS VIEW BUILDERS 2812 2814 Cazadero Dr Carlsbad, CA GeoTek, Inc. Base 7/6/2023 Project No.: 3856-SD DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Dry Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 5/4/23 1 Driveway in Front of 2812 Base 14.2 109.0 B 114.9 N 95 2 Driveway in Front of 2814 Base 12.0 109.7 B 114.9 N 95 5/10/23 3 Southbound Trench to East Prop.Base 10.8 117.2 C 122.0 N 96 4 Southbound Trench to East Prop.Base 10.1 116.9 C 122.0 N 96 5 Southbound Trench to East Prop.Base 9.8 118.1 C 122.0 N 97 5/11/23 6 Northbound adj to East Prop.Base 10.8 117.6 C 122.0 N 96 7 Northbound adj to East Prop.Base 10.1 116.8 C 122.0 N 96 8 Northbound adj to East Prop.Base 9.8 117.8 C 122.0 N 97 TABLE 4 SUMMARY OF FIELD DENSITY TESTS Base Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate CYPRESS VIEW BUILDERS 2812 2814 Cazadero Dr Carlsbad, CA GeoTek, Inc. Asphalt 7/6/2023 Project No.: 3856-SD DATE Test No.Location Lot No. Sta No. Elev/ Depth Moisture Content (%) Total Density (pcf) Soil Type Maximum Density (pcf) Test Type Relative Compaction (%) 5/10/23 1 Southbound Trench to East Prop.AC - 142.8 AC 145.6 N 98 2 Southbound Trench to East Prop.AC - 140.2 AC 145.6 N 96 3 Southbound Trench to East Prop.AC - 141.7 AC 145.6 N 97 5/11/23 4 Northbound adj to East Prop.AC - 142.8 AC 145.6 N 98 5 Northbound adj to East Prop.AC - 140.9 AC 145.6 N 97 6 Northbound adj to East Prop.AC - 141.7 AC 145.6 N 97 5/12/23 7 Northbound adj to West Prop.AC - 141.9 AC-2 146.1 N 97 8 Northbound adj to West Prop.AC - 142.1 AC-2 146.1 N 97 9 2812 & 2814 in Front of Prop.AC - 143.5 AC-2 146.1 N 98 10 2812 & 2814 in Front of Prop.AC - 145.8 AC-2 146.1 N 99 11 2812 & 2814 in Front of Prop.AC - 142.8 AC-2 146.1 N 98 12 2812 & 2814 in Front of Prop.AC - 140.9 AC-2 146.1 N 96 TABLE 5 SUMMARY OF FIELD DENSITY TESTS Asphalt Note: N = Nuclear Guage Test FG = Finished Grade Test All elevations are approximate Cypress View Properties, Inc. July 24, 2023 Geotechnical Final Soil Report Project No. 3856-SD 2812 & 2814 Cazadero, Carlsbad, California APPENDIX A As-Graded Geotechnical Report Hetherington Engineering, Inc. 2019 GEOTEK AS-GRADED GEOTECHNICAL REPORT Proposed Residential Duplex 2812 -2814 Cazadero Drive Carlsbad, California HETHERINGTON ENGINEERING, INC. HETHERINGTON ENGINEERING, INC. SOIL & FOUNDATION ENGINEERING • ENGINEERING GEOLOGY • HYDROGEOLOGY Cypress View Properties, Inc. 401 B Street, Suite 2400 San Diego, California 92101 Attention: Subject: Mr. Larry Figueroa AS-GRADED GEOTECHNICAL REPORT Proposed Residential Duplex 2812 -281 4 Cazadero Drive Carlsbad, California References: Attached Dear .tv1r. Figueroa: December 16, 2019 Project No. 8479.2 Log No. 20795 In accordance with your request, we have performed geotechnical services in conjunction with grading at the subject site. Our services consisted generally of the following: o Observation and density testing during grading. o Laboratory testing. o Engineering and geologic analyses. 0 The preparntion of this repo1i, which presents the results of our testing and observations, and our conclusions and reconm1endations. GRADING OPERATIONS Grading was performed during the period December 2 thrnugh December 13, 2019. Grading consisted generally of 3 to 4-feet of removals of loose/soft or disturbed fill down to approved fill and placement of compacted fill to design site grades. The attached Plot Plan, Plate No. 1 indicates the approximate limits of grading addressed by this report. The earthwork was performed by Mike Lloyd Excavation Company utilizing grading plans prepaJed by Christensen Engineering & Surveying. 5365 Avenida Encinas, Su ite A• Carlsbad, CA 92008-4369 • (760) 931-1917 • Fax (760) 931-0545 333 Third Street, Suite 2 • Laguna Beach, CA 92651-2306 • (949) 715-5440 • Fax (760) 931-0545 www. hetheringtonengi nee ring. com AS-GRADED GEOTECHNICAL REPORT Project No. 8479.2 Log No. 20795 December 16, 2019 Page 2 SITE PREPARATION Prior to grading, the site was cleared of existing smface obstructions, vegetation and debris. Within the areas of proposed construction, existing loose/soft or distmbed fill was removed down to approved fill. Following removals, the exposed soils were scarified to a depth of 6 to 8-inches, brought to near optimum moisture conditions and compacted to at least 90-percent relative compaction as determined by ASTM: D 1557. SOIL TYPES The soils utilized as fill consisted of on-site and import soils. The on-site soil was composed generally of mottled green, tan, and light brown silty sand and green, gray, and brown sandy clay. Import soil was composed generally of a gray sand with gravel. FILL PLACEMENT Fill soils were placed in 6 to 8-inch thick, near horizontal lifts, moisture conditioned to near optimum moisture content, and compacted to a minimum of 90-percent relative compaction as determined by ASTM: D 1557. Compaction was achieved by mechanical means using a Cat D6K track dozer and a Cat 950G rubber tire loader. A water hose was used for moistme conditioning. Density tests were performed in accordance with ASTM: D 6938 (Nuclear Method) and D 1556 (Sand Cone Method). The results of the density tests are presented on the attached Smmnary of Field Density Tests, Table I. The approximate locations of the field density tests are indicated on the accompanying Plot Plan, Plate 1. Maximum dry density/optimum moisture content determinations are presented on the attached Summaiy of Maximum Dty Density/Optimum Moisture Content Determinations, Table II. CONCLUSIONS AND RECOMMENDATIONS Based on our observations and the results of our testing, it is our opinion that the grading of the site has been performed in general conformance with our recommendations and the requirements of the city of Carlsbad. The portion of the site addressed by this report is considered suitable for the intended use. The recommendations for the proposed construction provided in the "Geoteclmical Investigation ... " (Reference 1) remain applicable. HETHERINGTON ENGINEERING, INC. REFERENCES 1. "Geotechnical Investigation, Proposed Residential Duplex, Lot 357, La Costa Meadows Unit No. 2, Cazadero Drive, Carlsbad, California", by Hetherington Engineering, Inc. dated July 31, 2018. 2. "Grading Plan for Cazadero Drive Condo Project, 28 12 -2814 Cazadero Drive, Carlsbad, CA", by Clu-istensen Engineering & Surveying, undated (Sheets 1 tlu·ough 6). HETHERINGTON ENGINEERING, INC. Project No. 8479.2 Log No. 20795 Project No. 8479.2 Log No. 20795 TABLE I SUMMARY OF FIELD DENSITY TESTS (ASTM: D 6938 & 1556) Test No. Test Date Soil Type Elevation (feet) Dry Density (pcf) Moisture Content (%) Relative Compaction (%) 1 12/2/19 1 455.3 111.5 15.4 93 2 12/2/19 1 456.4 109.2 17.1 91 3 12/2/19 1 456.3 107.6 17.4 90 4 12/2/19 1 457.5 108.1 16.2 90 5 12/2/19 1 457.6 109.8 17.9 91 6 12/3/19 1 455.0 105.6 16.6 88 (fail) 7 (retest of 6) 12/3/19 1 455.0 110.2 17.3 92 8 12/3/19 1 455.0 108.5 17.9 90 9 12/3/19 1 456.0 105.7 16.0 88 (fail) 10 (retest of 9) 12/3/19 1 456.0 108.9 16.4 91 11 12/3/19 1 456.5 110.1 16.1 92 12 12/11/19 2 458.0 117.2 14.2 92 13 12/11/19 2 457.9 118.8 12.7 93 14 12/12/19 2 458.2 117.3 14.2 92 15 12/12/19 2 458.1 113.7 15.6 90 16 12/13/19 2 458.8 115.7 12.4 91 17 12/13/19 2 458.8 115.7 11.9 91 18 12/13/19 2 458.8 114.8 15.1 90 19 12/13/19 2 458.8 114.1 14.9 90 20 12/13/19 2 458.8 118.1 12.0 93 21 12/13/19 2 458.3 120.1 12.5 95 22 12/13/19 2 458.3 124.6 10.2 98 23 12/13/19 2 458.3 121.9 12.3 96 Project No. 8479.2 Log No. 20795 TABLE II SUMMARY OF MAXIMUM DRY DENSITY/OPTIMUM MOISTURE CONTENT DETERMINATIONS (ASTM: D 1557) Soil Type Description Maximum Dry Density (pcf) Optimum Moisture Content (%) 1 Gray, green sandy clay 120.0 12.5 2 Gray brown sandy clay with gravel 127.0 10.0 LEGEND APPROXIMATE LOCATION OF DENSITY TEST APPROXIMATE REMOVAL BOTTOM ELEVATION (FEET) 1 23 454.5 3 2 4 1 5 7 6 118 9 10 454.5 454.3 454.3 454.3 454.4 454.3 454.6 454.5 454.5 454.4 APPROXIMATE LIMITS OF GRADING APPROXIMATE LIMITS OF GRADING BASE MAP: "GRADING PLANS FOR: CAZADERO CONDO PROJECT", SHEET 2 OF 7, CITY OF CARLSBAD, GR 2018-0035, GRADING PLAN SHEET PUD 2017-0003 12 13 15 16 17 18 19 20 14 21 22 23 PLOT PLAN GEOTECHNICAL CONSULTANTS HETHERINGTON ENGINEERING,INC. PROJECT NO.PLATE NO. 012 5 1015200 2812 & 2814 Cazadero DriveCarlsbad, California 8479.2 N SCALE: 1" = 10' ll07r NO. 354! 459.STW 457.STF lLOu NO. 35t4J. I I I 459.BTW 457.BTF I I / I I 459.STW 457.STF • • • [iJ UNITA 469.3 FF 458.6P • UNITB 459.3 FF 458.5 P I -- 1 r=•------• 468.8 458 458.STW 456.STF 455.5 FS l"lEl455.1' 455.7 FS TC ll':l 455.1' (!J IFl El 455.2' i "{' ro 1c a455.75' R. f.l 455.25' l'C EL 41:54.6' I I -@ I STA. 2+ 23.73 INSTALL 1"WATERSERVICE WITH 3/4" METER PERVWDW-6 SEE DETAIL "E" ON SHT 7 STA. 2+ 36.73 EXISTING 1" WATER SERVICE WITH NEW 3/4" METER PERVWDW-6 • - ) I 1 Cypress View Properties, Inc. July 24, 2023 Geotechnical Final Soil Report Project No. 3856-SD 2812 & 2814 Cazadero, Carlsbad, California APPENDIX B Updated As-Graded Geotechnical Report Hetherington Engineering, Inc. 2021 GEOTEK HETHERINGTON ENGINEERING, INC. SOIL & FOUNDATION ENGINEERING • ENGINEERING GEOLOGY • HYDROGEOLOGY Cypress View Properties, Inc. 401 B Street, Su ite 2400 San Diego, Califo rnia 92101 Attention: Mr. Ron Hiebert April 8, 2021 Project No. 8479.2 Log No. 21379 Subj ect: UPDATED AS-GRADED GEOTECHNICAL REPORT Residential Duplex 2812 -2814 Cazadero Drive Carlsbad, Cali fornia References: Attached Dear Mr. Hiebert: In accordance with your request, we have performed geotechnical services in conjunction with the precise grading of building pads, observation of footing excavations, and observation and testing of plumbing trench backfi ll at the subject site. Our services during grading and construction consisted generally of the following: • Observation and testing during grading. e Observation of footing excavations. • Observation and density testing of plumbing trench backfi ll. • Engineering and geologic analyses. o Preparation of this report, which presents the results of our testing and observations, and our conclusions and recommendations. GRADING OPERATIONS Previous rough grading at the site is summarized in the "As-Graded Geoteclmical Report ... " (Reference 2) and includes density test numbers l through 23 performed as part of rough grading. 5365 Avenida Encinas, Suite A • Carlsbad, CA 92008-4369 • (760) 931-1917 • Fax (760) 931-0545 333 Third Street, Suite 2 • Laguna Beach, CA 92651-2306 • (949) 715-5440 • Fax (760) 931 -0545 www. hetheringtoneng ineering .com UPDATED AS-GRADED GEOTECHNICAL REPORT Project No. 8479.2 Log No. 21379 April 8, 2021 Page 2 After the initial rougb grading of the site, the upper 1-foot \,vas scarified, moisture conditioned, and recompactecl to 90-percent relative compaction (ASTM: D l 557) on February 18, 202 1. Densit·y tests were performed in accordance witb J\STM: D 6938 (Nuclear Method). The results of the density tests are presented on the attached Summary of Field Density Tests, Tabl e I. The approximate locations of the field density tests are indicated on the accompanying Plot Plan, Figure No . 1. Maximum dry density/optimum moist1-irc content determinations are presented on the attached Summary of Maximum Dry Density/Optimum Ivfoistme Content Determinations, Table II. GEOLOGIC CONDITIONS Subsurface conditions encotmtered during precise grad ing and construction were consistent with those described in the "Geoteclmical Investigation ... " (Reference l ) and "As-Graded Geo technical Report. .. " (Reference 2). No groundwater \,vas encountered during precise grading and construction. FOUNDATION EXCAVATIONS Foundation excavations for the structures were observed by an engineer from th.is office. Footings were founded in approved compacted fill as recommended and dimensioned in accordance with the fo undation plans (Reference 4). PLUMBING TRENCH BACKFILL Plumbing trench backfill soils were placed in approximately 6 to 8-incb thick, near horizontal lifts, moisture conditioned to near optimum moisture content and compacted by mechanical means to a minimum of 90-percent relative compaction as determined by ASTM: D 1557. Density tests were performed in accordance with ASTM: D 6938 (Nuclear Method). The results of the field density tests are presented on the attached Summary of Field Density Tests, Table I. The approximate locations of the field density tests are indicated on the accompanying Plot Plan, Figure No. 1. Maximum dry density/optimum moisture content determinations are presented on the attached Summary of Maximum Dry Density/Optimum Moisture Content Determinations, Table II. HETHERINGTON ENGINEERING, INC. UPDATED AS-GRADED GEOTECHNICAL REPORT Project No. 8479.2 Log No. 21379 April 8, 2021 Page 4 Attachments: Plot Plan Summary of Field Density Tests Summary of Maximum Dry Density/ Optimum Moisture Content Determinations Pigure 1 Table l Tabl e JI Distribution: 1-via e-mail Ron Hiebert (Ron@cypressvievv.com) HETHERINGTON ENGINEERING, INC. R.Ef-EREN CES 1. "Geotechnical Investigation, Proposed Residential Duplex, Lot 357, La Cosla Meadows Unit No. 2, Cazadero Drive, Carlsbad, California", by Hetherington Engineering, Inc. dated July 31, 2018. 2. "As-Graded Geotcchnica l Report, Proposed Residential Duplex, 28 12 -2814 Cazadero Drive, Lot 357, Carlsbad, California", by .Hetherington Engineering, Inc. elated December J 6, 201 9. 3. "Grading Plan for Cazadero Drive Condo Project, 2812 -2814 Cazadero Drive, Carlsbad, CA", by Christensen Engineering & Surveying, undated (Sheets l through 6). 4. "Cazadero Drive Condo Project, Cazadero Drive, Carlsbad, CA 92009", Foundation Plan, Structmal Specs, and Structural Details, by Prentice Engineering, elated August 20, 2018 (Sheets SSJ, Sl.0, and S3.0). HETHERINGTON ENGINEERING, INC. Project No. 8479.2 Log No. 21379 LEGEND APPROXIMATE LOCATION OF DENSITY TEST29 29 28 25 27 26 24 1 N PLOT PLAN GEOTECHNICAL CONSULTANTS HETHERINGTON ENGINEERING,INC. PROJECT NO.FIGURE NO. 012 20 4001030 SC A L E : 1 " = 2 0 ' 8479.2 2812 & 2814 Cazadero DriveCarlsbad, California I I I I I 459.BTW 457.STF I I I / --~ i£ ,;; 1-.._ § 458.BFG 'itJ <§ @)L_ SD-7 I I '-----.____ § --I@) I@ -I • 458.BTW 456.BTF / I GEL454..:'!'_____ / 1-....c..::FL~a~, /, I _.., STA. 2+ 23-~RSERVICE I INSTALJ;,~~~R wtTHkow--6 7 _.., ~~: DETAIL "E" ON SHT -@ 2+36.73 STA. "WATER SERVICE EXISTING 1 314 .. METER WITH NED~-6 PERVW • TABLE I SUMMARY OF FIELD DENSITY TESTS (ASTM: D 6938) Test No. Test Date Remarks Soil Elevation Dry Density Moisture Relative Type (feet) (pct) Content Compaction (%) (Of«,) 24 2/18/2021 G ] 458.5 l 16.5 12.7 92 25 2/1 8/2021 G 1 458.5 12 1.7 11.4 96 26 2/18/2021 G I 458.0 124.2 7.2 98 27 3/23/2021 PT 1 458.0 11 5.7 13.3 91 28 3/23/2021 PT 1 458.5 115.6 8.5 91 29 3/23/2021 PT 1 458.5 11 7.4 10.8 92 G: Precise Grnding PT: Plumbing trench back Iii I TABLE II SUMMARY OF MAXIMUM DRY DENSITY/OPTIMUM MOISTURE CONTENT DETERMINATIONS (ASTM: D 1557 A) Soil Type Description 1 Grav brown sanely clay with gravel 2 Gray green sandy clay Maximum Dry Density <ocf) 127.0 120.0 Optimum Moisture Content (%) 10.0 12.5 Project No. 8479.2 Log No. 213 79