Loading...
HomeMy WebLinkAboutDWG 476-9SW; CT 05-12; BMP SITE PLAN - OCEAN STREET RESIDENCES; 0130 a• Ji SCALE: 1 "=30' ----- _.[ 2" FREEBOARD 6" PONDING (V1 STORAGE) i=IIl-24" SOIL MIX '1 I 15" MIN If'=· (V2 STORAGE) __.l_JUS,;l_L6!J.SJ__,_Sl.J.~~~Ei,)::,,GJ.l_g_j1=a!J1=a!JGJr~~i::'s:T ---II I - BIORETENTION AREA NTS V1 STORAGE PER DETAIL 3 HEREO~ CATCH BASIN PER PLAN SOIL MIX PER DETAIL HEREON ~,r.F"==xrq-:,1--,-6,. V2 STORAGE PER DETAIL 3 HEREON 4" PERFORATED UNDERDRAIN MIPT PVC ADAPTER CAST IN SIDE OF CATCH BASIN FLOW REMOVABLE FIPT PVC CAP Wl1H DRILLED ORIFICE HOLE, .-ORIFICE SIZE = O. 75" OUTFALL PIPE PER PLAN FLOW BIORETENTION AREA OUTLET STRUCTURE DETAIL NTS LEGEND (j) SUBGRADE ({) IMPERMEABLE LINER @ PLANTING PER LANDSCAPE PLANS @ 24" BIO-FILTRATION SOIL LAYER @ 12" CLASS 2 PERMEABLE BASE (6" SANDY LOAM OVER 18" LOAMY SAND)* 3" WASHED PEA GRAVEL 4" PERFORATED PVC DRAIN PI PE I , TYPE 'G' CATCH BASJN PER SDRSD D-8, TO~ bF GRATE 6" ABOVE FINISH GRADE. SEE OUTLET STRUCTUREIDETAIL HEREON. I, ' *24n SOib LAYER 1 SANDY l CAM CLAY 15-20J SILT 0-50% SAND 50-70% LOAMY SAND CLAY 10-15J SILT 0-30% SAND 70-85% 11NFJLTRATIDN RATE= 5 IN/HR MIN. PLANTER WALL OR GARAGE WALL - • j \ --· 18/ ' \CJ I .. -- ·--- BMP ID# BMP TYPE SYMBOL TREATMENT CONTROL ®-@ FLOW-THROUGH PLANTER CD-© BIORETENTION AREA INLET E LOW IMPACT DESIGN PERMEABLE PAVERS TURF BLOCK SOURCE CONTROL TRASH ENCLOSURE SWMP NO,; SWt.f' 13-01 CASQA NO. QUANTITY 8,000 SF TC-32 2 EA 2 EA SD-20 17,650 SF SD-20 5,100 SF SD-32 1 EA BMP TABLE DRAWING NO. SHEET NO.(S) 476-9A 3,5 476-9A 3,6 476-9A -9 476-9A 476-9A 3,5,6 476-9A 3,6 476-9A 5 INSPECTION FREQUENCY AFTER STORM EVENTS AFTER STORM EVENTS AFTER STORM s AFTER STORM EVENTS AFTER STORM EVENTS MAINTENANCE CONSTRUCTION FREQUENCY SIGN OFF Bl-ANNUAL Bl-ANNUAL QUARTERLY QUARTERLY QUARTERLY BI-ANNUAL MA I NTENANCE AGREEMENT DOCUMENT: YEs_x_ No_ RECORDATION NO.: 2013-0451268 RECORDATION DATE: JULY 19, 2013 PARTY RESPONSIBLE FOR MAINTENANCE: NAME: ZEPH(R PARTNERS CONTACT:JIM McMENAMIN ADDRESS: 1 '750 SORRENTO VALLEY ROAD, SUITE 130 SAN DIEGO, CA 92121 PHONE N0.:858-558-3650 PLAN PREPARED BY: NAME: DAVID WIENER COMPANY: RBF CONSULTING ADDRESS:5050 AVENIDA ENCINAS, SUITE 260 CARLSBAD, CA 92008 PHONE N0.:760-476-9193 CERTIFICATION:RCE #77285 BMP NOTES: 1. THESE BMPS ARE MANDATORY TO'BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS OR THESE PLANS. 2. NO OiANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 3. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER. 4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION AND INST ALLA TI ON . ROOF DOWNSPOUT PER LANDSCAPE PLANS 18" SOIL LAYER (TYP) (SEE TABLE TO RIGHT) 4" V1 STORAGE (TYP) 24" 24"x24" PRECAST GRATE INLET PER SHEET 10 PLANTER WALL PER DETAIL 6 ON SHEET 28 PIPE PENETRATION THROUGH WALL PER DETAIL 3 ON SHEET 21 18" SOIL LAYER 1 6" ¾NDY LOAM CLAY 15-20% SILT 0-50% SAND 50-70% OVER 12• LOAMY SAND CLAY 10-15% SILT 0-30% SAt-0 70-85J 11NFILTRATION RATE= 5 IN/HR MIN. E Cl a, ~ 0 ~ °'1 0.. <( ;;; 0.. ;;; (Il I ,... "' IMPERMEABLE MEMBRANE (TYP) 3" OUTFALL PIPE (CONNECT TO STORM DRAIN SYSTEM PER SHEET 10) r------------------~ .9- 4" PERFORATED UNDERDRAIN PIPE (TYP) MIN SLOPE= 0.5% FLOW-THROUGH PLANTER DETAIL NTS P.E. __ _ EXP.----DATE 0 0 <( t 0:: 0 0.. 1------------------~ REVIEWED BY: Vl z 0 ;:: INSPECTOR DA TE u ~----=-~::-=:-.~---:::--'--~::_---=-::_~------:,/-:~:---;:=.~~"' -~i~ =-~:_ =:c:::~!:::_==~-=::_ =:::::. ='.::::.==:-':':~!==---==---==--Tt=-_-=1~-==---~1=-:=-=--11-=-_ -=:-,-;::1 ::;:::SH,:::;EE:;:;:::T ;-';:I ~c~1r;;;=;Y~o:;:;F;::::c:;::;::A:;:::;R;::;LS;::;;:;:;;B;;:::A:;:::;n~1~sH:::1EE;;;;:;TS~I ~ ENGINEERING DEPARTMENT o :===-===============-===~ ~ ■ ■ ■ CONSULTING A -Company 1-----1----1----------------1---+--1----+---t BMP SITE PLAN FOR: z OCEAN STREET RESIDENCES ;;; 0 { l2 APP"O =, I_ -j :/)~ GLEN K. VAN PESKI § , REvisEo BIDRETENnDN AREA LocAnoNs Li.1/~ ~ 11/-zz/22, "' REVISED PLANTER DETAIL ENGEERING MANAGER PE 41204 EXPIRES 3 31 ,sr •1 DATE ;:J., 5050 AVENIOA ENCINAS, SUITE 260 j':': CARLSBAD, CALIFORNIA 92008-4386 t--::-=c--+-==-c--t--~A~D=D~R=OO~F ~D~OWN=S~PO=U~T~F~I=L T=E~RS~---t----+~cc--t----,---,--+-c---t DWN BY: ___ PROJECT NO. DRAWING NO. <: ?B0.475,9193 • FAX?B0,475-9196 • www.RBF.com EN~:~ ;N~:: REVISION DESCRIPTION o:; APP:~:~ D~~ APP~::: 2~~ ~r---CT 05-12 476-9SW ~ ...... ......,,.,,..,......., ______________________________ ...J..,...---------·---------------i.......;;....;,..,..;..J,, _____ ....,.. __ ....,.....,......;;;;,;;.;.;.;;;;,;;,;;;.,.t..,;~~;...~~~_;;;~iiiiiiiiiiii--iiiiiiiiiiiiiiiiiiiiiiiiiiiii'.~--iiiiiiiiiiiiiii'.I :c