HomeMy WebLinkAboutDWG 482-2SW; SDP 12-04; BMP SITE PLAN - HOEHN BUICK CADILLAC; 01-02SWMP NO. __ 1_4-~0_3 ~-
PARTY RESPONSIBLE FOR MAINTENANCE:
NAME HOEHN BUICK CADILLAC
ADDRESS 5334 PASEO DEL NORTE
CARLSBAD, CA 92008
PHONE NO. (8581755-7890
PLAN PREPARED BY:
BMPNOTES:
CONTACT BILL HOEHN
1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS OR THESE PLANS.
2. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR
APPROVAL FROM THE CITf ENGINEER.
3. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES
WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER.
4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF
HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION
AND INSTALLATION.
5. REFER TO MAINTENANCE AGREEMENT DOCUMENT.
6. SEE PROJECT SWMP FOR ADDITIONAL INFORMATION.
20' 10'
I
lPI
SCALE: 1"
0
20·
20'
GRAPHIC SCALE
0
NEW PAVEMENT
0
40'
"'
0
AREAD
DISTURBB), 51,®!;:SP';_--
VOLUME=
-----··-------
DATE INl11AL
ENGINEER OF WORK
0
C>V'✓fMPACT DESIGN (LLD.}
lo\ ROOF DRAIN TO • 0 LANDSCAPING
PERV!OUS
PAVEMENT
SOUR CONTROL
HENCLOSURE UJ
SD-11
TC-10
SD-32
2EA.
.JLll2lL SF.
1 EA.
SURFACE
/lJ?£4
OF
PLANTER
482-2A 3
482-2A 3
482-2A 3
L (VARIES)
r Cl.EANOUT STANO PIPE
PERFVRA TED PIPE
OOWNSPOUT/INLU
IRR/GATfON
SYSTEM
VAULT FABRICATED FROM
GAL VAN/ZED S~ BOLTED
TO !HE PLANTER INrE!?/Of?
(SEE FLOW-THROUGH
PLA.NTER Olffl.£! DITAIL}
PLAN
ANNUALLY ANNUALLY
SEMI-ANNUALLY ANNUALLY
..
WEEKLY AS NEEDED
EMERGENCY OL--fl?FLOW
,,-GRATE
(SEE FlOW-'THROUGH
PLANTER 0Un£T DETAIL)
~-•~OU~TFAl.l~'SPl:;,PE~C' ~
· .
1
_ -DISCHARGE TO AN
IA'"==st:· APPROVED LOCATION
;
H
• "'-CONCRETE: OR O'fl-lER
STRIJClVRAL PLANTEJ?
WALL WITH WATERPROOFING ENERGY DISSIPATION
OOKWSPOUT;1NLET~
ClEANOUT WITH ---H~
WA TERnGHT CAP
ABO\.£ PONDING' DEPTH V, STORAGE
18" AMEND£{) SOIL \
LOCKED, REMOVABt..E
CL05€-MESH GRAiE, ...----,I SLOPED INSTALLATION
#4 AT 16u O.C. fN· THE
CENTER EACH WA Y-WITH
4R EMBEOMENT PER
smUCT/JRAL ENGINEER
j4 AT 15" O.C. IN THE .
CENTER EACH WAY 1W
4" EMBEDMENT
PLANTER OU1l.ET
~ smuclURAL ENGINEER •1Mtm11::::c~·~1'!: 13"l" ~r::::erTri::-~'Uff;":;;;;.1111,:':1::3!!,]';'~-r:::::caJTl;.L~ci' 11El1::"'l~' 1[a··2i;:l,1)1;_1~)"iTi:,b~f-_J
~ 1JJ!lliJ~Will~~~]kTT~~~llli~u'.~
(Sf:£ Fl.OW:.. THROUGH-PlANTffi 01111..ET
DETAIL)
ONE~WAY
CONNECTIONS
#4 AT 16 .. O.C. IN E
CENTER EACH WAY lH PERFORATED PIPE
4,, EMBEDMENT PER ' {UNDERDRAIN}
STT?UCTURAL ENGINEER MIN SLOPE -= O.S%
SECTION
IRRIGATION SYSTEM
)-... ORIFICE DRILLED
INTO VAULT WALL
FORM A 1.5 .. GROOVE IN
CONCRETE ANO PROV/0£ A
CONllNUOUS WATERTIGHT
CONNECilON; USING Afl
APPROVED SEALANT
FLOW-THROUGH PLANTER DETAIL
OISCHARGE
TO AN
APPROVW
LOCATION
NEW PAVEMENT
I SH~ET I CITY OF CARLSBAD w ENGINEERING DEPARTMENT .L
SINGLE SHEET BMP SITE PLAN
SDP 12-04 CDP 12-26 V 13-02
HOEHN BUICK CADILLAC
5334 PASEO DEL NORTE
.
RECORD COPY PROJECT NO.
SOP 12-04
-
DATE INITIAL DATE INITIAL DRAWING NO. r:xe.-i/1/11,, I F• 482-2SvV REVISiON DESCRiPTION OlHER APPROVAL CITY APPROVAL INl11AL DAlE
SWMP NO. -~1~4-~03 __
PARTY RESPONSIBLE FOR MAINTENANCE:
NAME HOEHN BUICK CADILLAC
ADDRESS 5334 PASEO DEL NORTE
CARLSBAD, CA 92008
PHONE NO. (858) 755-7890
CONTACT BILL HOEHN
PLAN PREPARED BY:
NAME DANIEL RUBIO qi /;;;:___,~.{2)_:_;
COMPANY JONES, CAHL & ASSOCIATES
ADDRESS 18090 BEACH BLVD.
SUITE 12
HUNTINGTON BEACH, CA 92648
PHONE NO. (714) 848-0566
BMP NOTES:
SIGNATURE
CERTIFICATION -~R~CE~6~0~934~_
1. THESE BMPS ARE MANDATORY TO BE INSTALLED PER MANUFACTURER'S
RECOMMENDATIONS OR THESE PLANS.
2. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITHOUT PRIOR
APPROVAL FROM THE CITY ENGINEER.
3. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES
WITHOUT PRIOR APPROVAL FROM THE CITY ENGINEER
4. NO OCCUPANCY WILL BE GRANTED UNTIL THE CITY INSPECTION STAFF
HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUCTION
AND INSTALLATION.
5. REFER TO MAINTENANCE AGREEMENT DOCUMENT.
6. SEE PROJECT SWMP FOR ADDITIONAL INFORMATION.
EXIST/NC_
BUii.DiNG &
OV[I//-IANC
\
\
\
\
\
\
\
\
\
,. 1d -,\'' .;-/
,, -
v,
I
[L[C TRICJIL -
CONUUIT
/
UNDISTURBED AREA
104,462 SF
------'c-, w----·-
DATE INITIAL
ENGINEER OF WORK
--.,A
BMP TABLE
SHEET NO.(S) INSPECTION * MAINTENANCE * BMP ID# BMPTYPE SYMBOL CASQA NO. QUANTITY DRAWING NO. FREQUENCY FREQUENCY
' TREATMENT CONTROL
0-0 BIORETENTION • • • +-TC-32 __IfilLSF. 482-ZA 3 QUARTERLY SEMI-ANNUALLY • • +-• • AREA • • • •
®-® FLOW-THROUGH . . . TC-32 __453___ SF. 482-ZA 3 QUARTERLY SEMI-ANNUALLY PLANTER . .
,1
HYDROMODIFICATION & TREATMENT CONTROL '
HYDROMODIFICATION
~
\-sea ,
LOW IMPACT DESIGN (L.1.D.)
CD-0 ROOF DRAIN TO • SD-11 2EA. 482-ZA 3 ANNUALLY ANNUALLY LANDSCAPING
0-® PERVIOUS ~ TC-10 ~SF. 482-ZA 3 SEMI-ANNUALLY ANNUALLY PAVEMENT
'"-SOURCE CONTROL
@ TRASH ENCLOSURE LU SD-32 1 EA. 482-ZA 3 WEEKLY AS NEEDED
~ ~~ "'-' ~,i_ l XiS TINC !/U1l.,rl1,V','
~,'-8>, ,1-;,1).,; PA ·)l () (Ii f,J()J,) !/
I :(
~;<"
c,-' ~--\i.:-,' ,::.._v' .. ;f-_, -J
DATE INITIAL DATE INITIAL
REVISION DESCRIPTION OTHER APPROVAL CITY APPROVAL
".)
( \~-~ <--:\,
20·
N
10'
Ill
SCALE: 1" -20'
0 20· 40'
GRAPHIC SCALE
I SH~ET I CITY OF CARLSBAD I SH~ETS I
ENGINEERING DEPARTMENT
SINGLE SHEET BMP SITE PLAN
SDP 12-04 CDP 12-26 V 13-02
HOEHN BUICK CADILLAC
5334 PASEO DEL NORTE
RECORD COPY PROJECT NO.
SOP 12-04
pi?R-7 f,_ '-1 /!l/ I DRAWING NO.
I INITIAL 6A1E 482-2SW