Loading...
HomeMy WebLinkAboutDWG 487-6SW; SDP 96-02A; BMP SITE PLAN - SAINT PATRICK PARISH SCHOOL; 01I \( /\ lf NOiE: •• ALL EXISTING NON-DISTURBED AREAS\ £AST OF TH£ DMA BORDER WILL NOT CO-MINGL£ WITH PROPOSED PROJ£CT DURING. WA T£R QIJ!)UTY Df$J STORM._. I !8 u1 -r•J ,/eL--\~'w, 71== I 1u) {qJ'.,/ iJDi"!T :-~·· l,,. \ ,. i ' , ~ '/ .,_ 1-' ,_ • • ,. ' \ DESIGNER: SG : STUART ENGINEERING DRAWN. SG : 7525 METROPOLITAN DRIVE STE. 308 -I--D-A_T£ ___ ------1 SAN DIEGO, CA 92108 (619) 296-1010 10-30-15 FAX (619) 296-9276 EMAIL: S[@s/uar/engineering.com 1----------l JOB NO• 1332-14-00 -.✓ • i / j r r \ REVISED 10-30-15 REVISED 10-7-15 30 SWMP NO. 15-09 PARTY RESPONSIBLE FOR MAINTENANCE NAM£: SAINT PA TRICK CA THOLIC CHURCH 3820 PIO PICO DRIVE • CARSLBAD, CA 92008 PHONE:(760} 729-1333 CONTACT NAM£· FATHER BILL ROWLAND BMP NOTES: 1. 2. 3. 4. 5. 6. 15 -. 0 THESE BMPS ARE MANDA TORY TO BE INSTALLED PER MANUFACTURERS RECDMMENDA TIONS OR THESE PLANS. NO CHANGES TO THE PROPOSED BMPS ON THIS SHEET WITH PRIOR APPROVAL FROM THE CITY ENGINEER. NO SUBSTITUTIONS TO THE MATERIAL OR TYPES OR PLANTING TYPES WITHOUT PRIOR APPROVAL FJOM THE CITY ENGINEER. NO OCCUPANCY WILL BE GRANTED UNTIL i THE CITY INSPECTION STAFF HAS INSPECTED THIS PROJECT FOR APPROPRIATE BMP CONSTRUC~ON AND INSTALLATION, REFER TO THE MAINTENANCE AGREEMENT DOCUMENT. SEE PROJECT SWMP FOR ADD/TONAL INFORMATION. 30 SCALE IN FEET ! 60, DATE - - INITIA~ ENGINEER OF WORK ------------ LEGEND:· OMA BOUNDARY --PROPOSED STORM DRAIN DRAINAGE MANAGMENT AREA (OMA) (o.J4AQ BIO-RETENTION BASIN DRAINAGE MANAGEMENT AREA DMA-2 MODULAR WETLAND SYSTEM DESIGNATOR EXISTING STORM DRAIN --SU---LANDSCAPE (PERVIOUS} AREA PROJECT BOUNDARY ----SELF-RETAINING AREA STORM DRAIN CLEANOUT co CATCH BASIN CB SELF-TREA TING AREA MODULAR WETLAND TREATMENT CALCULATIONS oMi' ~fl'u'i' 2.lQ Noipis.: .,. pllj,o. 'Area ra~f11 0.84 <!l\jA RV~pft, F~ijqr· ~) ~tV:i ~ • &r1,;-~!fi~-_:t~:,Fc~µr;~fci-f.; ~:~igfi~·,,j;~a~,/it~ tei;t,IJr;@Jt f~ct~f ? ) :fi"lr -~~itf,:f;.bf MtrdW:i'! r:We~!~nq-.-~V!i1::~.!Jl, ·-~-e-. A p_i;;p_qj:ii:,,4 _ fff;j'.Cfl){E JREAJ'M£Nf AlirA Mf~ltri~'.~ :Affl.1:.'!.unt,of ~~-~m~~t'fr,~ R,~ut_~d',(ilcr~} BIO-RETENTION BASIN TREATMENT CALCULATIONS SELF-TREA TING CALCULATIONS QMA Runi:,tf Factqt fi)i\.1). lire~ )( Ruri<>ff)\ac;ior J, , ",,,,);', ' ,Se.ff•l'teat1rig,talculaticms . . . ohgi , 4Y . , D 0 SELF:_RETAINING CALCULATIONS BMP TABLE Sizfog Factor Miririnum tirnd~rit or· TreatrnenlArea ijequi(;~Jsq{ft( A¢1?3t Tre,rtm¢~t ••• Jueatl!toii:i<led {1'1I c>-• (elentiqn !Jasin)• (sq-It} BMP ID# BMP TYPE SYMBOL CASQA NO. QUANTITY DRAWING NO. SHEET NO.(S) INSPECTION * MAINTENANCE * . FREQUENCY FREQUENCY . TREATMENT CONTROL i @+@ MODULAR ~ NIA 2 EA. 478-BA 2, 5 QUARTERLY ANNUALLY WETLAND . f8::8=8 . • . -! @ BIO-RETENTION TC-32 534 SF. 478-BA 2,3, 5 QUARTERLY B1-ANNUALL Y .. LOW IMPACT DESIGN (LLD.) G)-Q) . ROOF DRAIN TO @ NIA 3EA. 478-BA 5 ANNUALLY ANNUALLY LANDSCAPING SOURCE CONTROL - . (J) w TRASH ENCLOSURE SD-32 1 EA. 478-BA 3 WEEKLY AS,NEEDED . ' @-@ -. i STENCILS NO DUMPING SD-13 14 EA 478-BA 3, 5 QUARTERLY AS;NEEDED DRAINS TO OCEAN A i . THIS PROJECT IS EXEMPT FROM HYDROMODIFICATION -. I SH~ET I CITY OF CARLSBAD I SH~ETS I ·-• ENGINEERING DEPARTMtNT - SINGLE SHEET BMP SITE PLAN _-. . . SAINT PATRICK -PARISH SCHOOL . . . . -... . RECORD COPY • PROJECT NO. SOP 96-02A OcfL \1[1..-<t/c,r DRAWING NO. DATE INITIAL DATE INITIAL REVISION DESCRIPTION , ' 487-6SW OTHER APPROVAL CITY APPROVAL INITIAL DATE . . 7 I