Loading...
HomeMy WebLinkAboutCT 04-14A; TRAILS END; REVIEW OF INTERLOCKING PAVER DESIGN FOR PLANNED ACCESS ROAD; 2019-09-19Geotechnical C Geologic C Coastal C Environmental 5741 Palmer Way C Carlsbad, California 92010 C (760) 438-3155 C FAX (760) 931-0915 C www.geosoilsinc.com TECHNICAL M EM 0 RAN DU M Date: September 19, 2019 To: Donna Drive, LLC 5505 Canca De Golf Rancho Santa Fe, California Attn: Mr. Dan Hayden j W From: Robert C. Crisman, CEG 1934 David W. Skelly, RCE 47857 Exp. 3-31-20 W.O. 6635-E-SC No, RCE 4' * \Exp. —1-L- L, * OFC& Subject: Review of Interlocking Paver Design for Planned Access Road, Trails End Development, CT 04-14, Northwest Corner of the Donna Drive and Carlsbad Village Drive Intersection, Carlsbad, San Diego County, California References: 1. "Review of Pavement Design, Trails Lane (Private), Trails End Development, CT 04-14, Northwest Corner of the Donna Drive and Carlsbad Village Drive Intersection, Carlsbad, San Diego County, California," dated August 9, 2018, by GeoSoils, Inc. 2."Geotechnical Discussion and Review, Retaining Wall Drainage and Permeable Pavement Design/Construction, Proposed Trails End Development, Northwest Corner of the Donna Drive and Carlsbad Village Drive Intersection, Carlsbad, San Diego County, California, W.O. 6635-A-SC, Dated March 20, 2014, by GeoSoils, Inc. 3. "Geotechnical Update Evaluation, Proposed Trails End Development, Northwest Corner of the Donna Drive and Carlsbad Village Drive Intersection, Carlsbad, San Diego County, California," W.O. 6635-A-SC, dated November 27, 2013, by GeoSoils, Inc. In accordance with your request, GeoSoils, Inc. (GSI), has evaluated soil subgrade and pavement design/construction for the planned access road at the site. Unless specifically superceded herein, the conclusions and recommendations presented in Reference Nos. 1 and 2 remain valid and applicable. It is our understanding that pavement for the planned access road will consist of interlocking payers able to support an AASHTO "H-20" load (i.e., fire trucks, service trucks, etc.). Based on our review and analysis, including the minimum AASHTO load criteria, the following paver section design and construction recommendations are provided. The exposed subgrade soil should be scarified, moisture conditioned, and compacted to a minimum relative compaction of 95 percent, and near optimum moisture content, per ASTM D 1557. The structural section should consist of the paver and underlying leveling coarse of sand overlying a minimum 8 inches of compacted aggregate base. The sand leveling course thickness and gradation shall be per the manufacturers specifications. The minimum relative compaction required for base rock will be 95 percent of the laboratory maximum density as determined by ASTM test designation D 1557. As required, base aggregate shall be in accordance with: Section 26 of Caltrans Standard Specifications for Class II aggregate base; or Section 200-2.2 for crushed aggregate base, or section 200-2.4 for crushed miscellaneous base, in the Standard Specifications for Public Works Construction (Greenbook). A concrete "transition" strip, "edge restraint," or "divider" should be provided between the payers and the adjacent ground. The transition strip should be at least 4 inches wide, with a depth equal to the total thickness (depth) of the paver and base section. The pavement subgrade is not anticipated to readily infiltrate any surface water that may migrate through the payers into the underlying base. As such, a subdrain should be considered along the down gradient edge of the paver section, where the pavement abuts (transitions to) the planned "grasspave" pavement. The subdrain shall consist of a minimum 4-inch diameter perforated PVC pipe (SDR 35, or equivalent) embedded within, and not more than 1 inch from the base of the "structural" or aggregate base layer. The subdrain should be properly outlefted to a suitable discharge area. For improved pavement performance, a woven geotextile (Mirafi HP 570, or equivalent) may be placed on the subgrade surface prior to base placement. The conclusions presented herein are professional opinions. These opinions have been derived in accordance with current standards of practice, and no warranty is express or implied. Standards of practice are subject to change with time. GSI assumes no responsibility or liability for work or testing performed by others, or their inaction, or work performed when GSI is not requested to be onsite, to evaluate if our recommendations have been properly implemented. Use of this report constitutes an agreement and consent by the user to all the limitations outlined above, notwithstanding any other agreements that may be in place. In addition, this report may be subject to review by the controlling authorities. Distribution: Addressee (email) Donna Drive, LLC Trails End, Carlsbad File: e:\wp9\6600\6635e.pdr.access GeoSods, Inc. W.O. 6635-E-SC September 19, 2019 Page 2