HomeMy WebLinkAboutCT 05-10; POINSETTIA PROPERTY; PRELIMINARY TURF BLOCK RECOMMENDATIONS; 2010-09-14a Earth Sitraita 1/inic.. Geotechnical, Environmental and Materials Testing Consultants BETTER PEOPLE • BETTER SERVICE • BETTER RESULTS September 14, 2010 Project No. 10707-10B Mr. John Norum K. HOVNANIAN HOMES 1500 South Haven Avenue, Suite 100 Ontario, CA 91761 Subject: Preliminary Turf Block Recommendation Letter, Proposed Residential Development, Located on the Southwest Corner of Poinsettia Lane and Lowder Lane, City of Carlsbad, San Diego County, California Reference: Earth-Strata, Inc., 2010, Preliminary Geotechnical Interpretive Report, Proposed 29-Lot Residential Development, Located on the Southwest Corner of Poinsettia Lane and Lowder Lane City of Carlsbad, San Diego County, California, dated May 11. Pursuant to your request, Earth-Strata is providing pavement design recommendations for Portland cement concrete pavement sections for the proposed sewer access maintenance road in the northwest portion of the subject property, which is located on the southwest corner of Poinsettia Lane and Lowder Lane in the City of Carlsbad, San Diego County, California. Representative samples of the subgrade earth materials were obtained from the subject site. The earth materials were tested for R-value in conformance with the California Test Method No. 301. The preliminary test results indicated an R-value of 57 for the subject site. Final design should be based on sampling and testing of post graded conditions. Based on the anticipated site conditions and our review of the Typical Grasspave 2 Detail for the turf block product by Invisible Structures, Inc., we recommend the following. PORTLAND CEMENT CONCRETE PAVEMENT Street Type R-Value Turf Block Aggregate Base Sewer Maintenance Access Road 50 Grasspave 2 6 inches Subgrade materials immediately below the aggregate base should be compacted to a minimum of 95 percent relative compaction based on ASTM Test Method D1557 to a minimum depth of 6 inches. Final subgrade compaction should be performed prior to placing base or turf block and after all utility trench backfill has been completed. Base materials should consist of Class 2 aggregate base conforming to Section 26-1.02B of the State of California Standard Specifications or crushed aggregate base conforming to Section 200-2 of the Standard Specifications for Public Works Construction (Greenbook). Base materials should be compacted to a minimum of 95 percent relative compaction based on ASTM Test Method D1557. The base materials EARTH - STRATA, INC. - 26047 JEFFERSON AVENUE, SUITE C, MURRIETA, CA 92562 OFFICE (951)461-4028 FAX (951) 461 -4058 . WWW.EARTH-STRATA.COM BETTER PEOPLE - BETTER SERVICE - BETTER RESULTS should be at or slightly below optimum moisture content when compacted. Portland cement concrete materials and construction should conform to Section 201 of the Greenbook. The opportunity to be of service is appreciated. Should you have any questions or require further clarification, please notify our office at your earliest convenience. Respectfully submitted, 1EA1UT]H[STRA1FA,. l[NC. Chad E. Welke, PG, CEG, PE Vice President Principal Geologist! Engineer Distribution: (2) Addressee (2) Mr. Tom Hespeler, Rick Engineering E. 9 NO, C63712 EXP. 09-30 1 A 4A L4 OF GP EA]K1r]HSTRATA, ]INC. 2 September 14, 2010