Loading...
HomeMy WebLinkAboutMS 16-06; CARLSBAD VILLAGE LOFTS; RESPONSE THE CITY OF CARLSBAD REVIEW COMMENT; 2019-03-22cmri~, " Construction Testing & Engineering, Inc. Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying March 22, 2019 CTE Job No. 10-14798G Wermers Properties Attn: Austin Wermers 5080 Shoreham Place, Suite 105 San Diego California 92122 (858) 623-4958 Via Email: AustinW@wermerscompanies.com Subject: Response the City of Carlsbad Review Comment Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700) Carlsbad, California Mr. Wermers: Construction Testing and Engineering, Inc. (CTE) has reviewed the City of Carlsbad Review Comment associated with the Proposed Carlsbad Village Drive Apartments with regards to preliminary recommendations for the BMP's at the subject site. The comment was noted to be a redline on the cover page of the referenced Updated Preliminary Geotechnical Recommendations and Grading Plan Review Letter. CTE understands that the specific recommendations pertinent to the proposed "Tree Wells" are required. As required and requested, update recommendations associated with the proposed "Tree Wells" are presented herein. Recommendations in the referenced report not specifically modified or provided herein remain applicable for use during project design and construction. However, CTE reserves the right to further modify recommendations and/or provide additional recommendations based on the actual conditions encountered at the site during earthworks and construction. 1.0 UPDATED GEOTECHNICAL RECOMMENDATIONS. PROPOSED "TREE WELLS" CTE performed percolation testing during the initial site geotechnical investigation conducted in December of 2015. The evaluation was performed in general accordance with Appendix C of the Model BMP Design Manual for the San Diego Region "Geotechnical and Groundwater Investigation Requirements", dated January 2018. Documentation of the percolation testing is provided in the Preliminary Geotechnical Report, dated January 27, 2016, and is provided as an attachment in the referenced Updatereiminap Got TEED l Recommendations and Grading Plan Review Letter. j1'KJ C L 111 V JUN 24 2019 1441 Montiel Road, Suite 115 1 I Fax (760) 746-9806 I www.cte-inc.net Response the City of Carlsbad Review Comment Page 2 Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700) Carlsbad, California March 22, 2019 CTE Job No. 10-14798G The referenced Updated Preliminary Geotechnical Recommendations and Grading Plan Review Letter contain Worksheet 1-8, which provided information concerning the categorization of infiltration feasibility condition. CTh's response to Criteria Number Two and Criteria Number Six of the aforementioned worksheet provided recommendation concerning the feasibility of infiltration without increasing the risk of geotechnical hazards. Recommendation specific to the "Tree Wells" detailed on Sheet 7 of the referenced Grading Plan Set are as follows: Lining the sides of the "Tree Wells" with impermeable liner is recommended to reduce lateral migration of infiltrate. The lining should extend to a depth such that infiltrate enters the subgrade outside of a 1:1 (Horizontal: Vertical) plane extending up from the bottom, outside corner of adjacent foundation excavations and utility trenches within 50 feet. CTE recommends relocating "Tree Wells" in the circumstance that the aforementioned parameters are infeasible. CTE understands that the proposed site Bio-Filtration Basins are lined on sidewalls and bottoms with impermeable liners, as storm water intercepted by the basins is anticipated to be diverted to adjacent storm drains following bio-filtration. 2.0 LIMITATIONS This letter is subject to the same limitations as previous CTE geotechnical documents issued for the subject project. CTE's conclusions and recommendations are based on an analysis of the observed conditions. If conditions different from those described in the reports are encountered during construction, this office should be notified and additional recommendations, if required, will be provided. \\ESC_SERVER\Piojects\10-14798G\Ltr_Response to Review Commeuts.doc Response the City of Carlsbad Review Comment Page 3 Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700) Carlsbad, California March 22, 2019 CTE Job No. 10-14798G The opportunity to be of service on this project is appreciated. If you have any questions regarding this report, please do not hesitate to contact the undersigned. Respectfully submitted, CONSTRUCTION TESTING & ENGINEERING, INC. c) 7. / / 1 F. Lynch, CEG #1890 (jPrincipal Engineering Geologist o No. 1890 Th CERTIFIED - ENGINEERING * * GEOLOGIST tP Exp. 5131t) - Dan T. Math, GE# 2665 Vice President, Principal / artinez OF Staff Geologist MDMIJFL/DTM:nri References: Updated Preliminary Geotechnical Recommendations and Grading Plan Review Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700) Carlsbad, California CTE Job Number 10-14798G. dated February 28, 2019 Grading Plan Sheets lthrough 7, City of Carlsbad Project No. MS 16-06, Drawing 515-5A Carlsbad Village Lofts 1044 Carlsbad Village Drive Carlsbad, California Prepared by SB&O Engineering \\ESQSERVER\Projects\I0-I4798GLfr_Responoe to Review Commenisdoc