Loading...
HomeMy WebLinkAboutMS 16-06; CARLSBAD VILLAGE LOFTS; UPDATED PRELIMINARY GEOTECHNICAL RECOMMENDATIONS - ADDENDUM 01; 2019-03-31'5~ CTE I~,,, 'J. S S Construction Testing & Engineering, Inc. Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying III March 31, 2019 JUN 24 2019 CTE Job No. 10-14798G Wermers Properties LAND DEVELOPMENT Attn: Austin Wermers ENGINEERING 5080 Shoreham Place, Suite 105 San Diego California 92122 (858) 623-4958 Via Email: AustinW@wermerscompanies.com Subject: Updated Preliminary Geotechnical Recommendations - Addendum 01 Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700) Carlsbad, California References: Updated Preliminary Geotechnical Recommendations and Grading Plan Review Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700) Carlsbad, California CTE Job No. 10-14798G, dated February 28, 2019 Geotechnical Investigation Proposed Carlsbad Village Drive Apartments 1044 Carlsbad Village Dive Carlsbad, California CTE Job No. 10-12371G. dated January 27, 2016 Mr. Wermers: As requested, Construction Testing and Engineering, Inc. (CTE) provides the updated geotechnical recommendations herein as an addendum to the referenced geotechnical report. These recommendations are provided in response to an email request from the structural engineer (VCA Structural), which is provided herewith. Updated and/or additional geotechnical recommendations are provided below and are numbered per the information requests in the aforementioned email, and supersede any conflicts with previously provided recommendations. 4.3 Groundwater Conditions Based on review of the boring logs from CTE's referenced 2016 report, groundwater was not encountered at the site to the maximum explored depth of 18.5 feet below existing ground surface (bgs). However, based on review of available documents on the State Water Resources Control Board's (SWRCB's) Geotracker database for the subject site and nearby sites, groundwater has been encountered at approximately ten feet bgs. Additionally, groundwater 1441 Montiel Road, Suite 115 1 Escondido, CA 92026 1 Ph (760) 746-4955 1 Fax (760) 746-9806 1 www.cte-inc.net Updated Preliminary Geotechnical Recommendations - Addendum 1 Page 2 Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700), Carlsbad, California March 31, 2019 CTE Job No. 10-14798G elevations may fluctuate due to precipitation and other causes. Therefore, we believe a conservative design groundwater elevation of ten feet bgs is appropriate. 5.5 Fifi Materials A conceptual retaining wall backdrain detail was provided as Figure 4 to CTE's 2016 geotechnical report. This conceptual detail may or may not be used by the appropriate professional, at their discretion, to detail specific retaining wall backdrains and waterproofing, as appropriate, for the project. 5.8.1 Foundations Based on review of the boring logs from CTE' s referenced 2016 report, Paralic Deposits are anticipated to be encountered at approximately 1.5 feet bgs across the site. For foundations near grade (i.e., foundations not at depth for the subterranean parking structure), foundation dimensions and reinforcement should be based on an allowable bearing value of 2,500 psf for footings embedded a minimum of 24 inches below nearest adjacent subgrade elevation and into competent formational materials. An allowable increase of 250 psf may be applied for each additional six inches of embedment up to a maximum allowable bearing value of 4,500 psf. Continuous footings should be at least 24 inches wide; isolated footings should be at least 36 inches in least dimension. The above bearing values may also be increased by one third for short duration loading which includes the effects of wind or seismic forces. Maximum total and differential static settlement estimates for near-grade foundations should be considered to be the same as the previously provided total and differential static settlement for at-depth foundations. However, it is anticipated that shallow structure footing will be stepped down gradually to remain embedded in native materials and transition down to the deeper level basement foundations. Additional deepening of all foundations could be required based on the actual conditions encountered during construction. A 140 pci uncorrected subgrade modulus of reaction is also considered appropriate for near- grade foundations in competent native materials. The following equation can be used to calculate the corrected subgrade modulus of reaction, k, based on footing size: k=k1 *((B+ 1)/2B)2 where k1 is the uncorrected subgrade modulus of reaction and B is the footing width. Please note that, depending on the methods used for constructing the subterranean portion of the structure (e.g., typical excavation with laid back temporary slopes, temporary shoring, etc.), it may be necessary to deepen or step-down near-grade footings as they approach the subterranean \\ESC_SERVER'Projects\10-14798G\Ltr_Geo Adendum 01 & Response to Structural.doc Updated Preliminary Geo chnical Recommendations - Addendum 1 Page 3 Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700), Carlsbad, California March 31, 2019 CTE Job No. 10-14798G portion of the structure to ensure that they continuously bear on undisturbed, dense, competent native materials, and that they extend through any fill placed during construction. 5.8.2 Foundation Settlement As it is anticipated that all foundations will be embedded into competent formational materials, the previously provided estimates for total and differential static and dynamic settlement remain unchanged. 5.8.4 Interior Concrete Slabs Based on review of the boring logs from CTE's referenced 2016 report, groundwater was not encountered at the site to the maximum explored depth of 18.5 feet below existing ground surface (bgs). However, based on review of available documents on the State Water Resources Control Board's (SWRCB's) Geotracker database for the subject site and nearby sites, groundwater has been encountered at approximately ten feet bgs. Additionally, groundwater elevations may fluctuate due to precipitation and other causes. Therefore, we believe a conservative design groundwater elevation often feet bgs is appropriate. 5.10 Lateral Resistance and Earth Pressures For typical street or other traffic that remains more than 10 feet away from retaining structures, surcharge loading may be neglected. Retaining structures up to 15 feet in height that may receive traffic surcharging within 10 feet of the back of the retaining structure should be designed to resist a uniform lateral pressure of 100 pounds per square foot (psf) that results from an assumed 300-psf surcharge behind the shoring due to typical street or other traffic. The following equations may be used to calculate lateral pressures on cantilevered retaining walls (yielding walls) over six feet in height (based on the work by Seed & Whitman, 1970) and restrained (non-yielding) over six feet in height (based on the work by Wood, 1973): YIELDING CASE PAE = PA + APAE PA/b = Static Active Earth Pressure = GhH2/2 zPIb = Dynamic Active Earth Pressure Increment = (3/8) kh 7H2/2 NON YIELDING CASE PKE = PK + APKE PK/b = Static Restrained Wall Earth Pressure = GhH2/2 APKEIb = Dynamic Restrained Earth Pressure Increment = kh'yH2/2 where: b = unit length of wall (usually 1 foot) kh = '/2k PGA,,, (PGAm given previously Table 5.9) \\ESC_SERVER\Projects\10-14798G'Ltr_Geo Adendum 01 & Response to Structural .doc çOFEs CD Q L1.j1 )YO- 84406 1m EXpg,301 j Dan T. Math, GE# 2665 Vice President, Principal 0ESSIO 2655 OFC * GEOL 5lc F C )Cipal J ynch,CEG#1890 P Engineering Geologist Co . Kenny, RCE #84406 Senior Engineer CJKIJFL/DTM:nri Updated Preliminary GeoVnical Recommendations - Addendum 1 Page 4 Proposed Carlsbad Village Lofts 1044 Carlsbad Village Drive (APNs: 203-320-3200, -3900, & -4700), Carlsbad, California March 31, 2019 CTE Job No. 10-14798G Gh = Equivalent Fluid Unit Weight (given previously Table 5.10) H = Total Height of the retained soil y = Total Unit Weight of Soil z 135 pounds per cubic foot *A 1/2 reduction factor is anticipated to be acceptable based on the assumption that the walls are not overly sensitive to some movement during the design seismic event, but this should be confirmed or determined by the project structural engineer (see SEAOC, 2013). If the walls are considered to be overly sensitive to some movement during a seismic event, a 2/3 reduction factor may be feasible at the discretion of the project structural engineer and governing authority. The increment of dynamic thrust in both cases should be distributed triangularly with a line of action located at H/3 above the bottom of the wall (SEAOC, 2013). The opportunity to be of service on this project is appreciated. If you have any questions regarding this report, please do not hesitate to contact the undersigned. Respectfully submitted, CONSTRUCTION TESTING & ENGINEERING, INC. \\ESC_SERVER\Projects\I0-14798G\Ltr_Geo Adendum 01 & Response to Structural.doc Natasha Indegno From: Austin Wermers <austinw@wermerscompanies.com > Sent: Thursday, March 28, 2019 3:30 PM To: Dan Math Cc: Phuong Do (Structural); Eugene Kuehl; Tam Nguyen (Structural); Kia Assadzadeh; Ed Wu Subject: RE: Carlsbad Village Lofts - Soils Report Review Dan, please see the below email From: Tam Nguyen (Structural) [mailto:Tam . Nguyen @vcastructural.com] Sent: Thursday, March 28, 2019 3:25 PM To: Austin Wermers <austinw@wermerscompanies.com>; Kia Assadzadeh (kiaa@architectsorange.com) <kiaa@architectsorange.com>; Ed Wu (edwardw@architectsorange.com) <edwardwarchitectsorange.com> Cc: Phuong Do (Structural) <Phuong.Docvcastructural.com>; Eugene Kuehl <Eugene.Kuehl@vcastructural.com> Subject: Carlsbad Village Lofts - Soils Report Review All— We have reviewed the soils report for Carlsbad Village Lofts and have the following comments for the soils engineer. Please forward these on to him to so that he can provide responses. Thanks. 4.3 Groundwater Conditions 1) Provide design groundwater elevation. 5.5 Fill Materials 1) Detailing wall backdrains is not in structural percent passing the Na. 200 sieve. The upper 12 to 18 inches ofwalt bickfihI couldconsistoflowcr peniieabftit' soils, in order to rchioe surface water intiiimtioit behind walls. Th ti uiu (LI b" r1it1 r1,11. IJuu qn.* liowcvcr, a conceptual wall backdram de-tai L which may or may not he suitable for use at the site, is pmvidcd as Fiurc 4. 5.8.1 Foundations 1) Not all foundations @ subterranean; Retail is on grade. indicated, it is anticipated that the proposed structure footings will be fH1I dtidé to the proposed le ci ofsubtenaneanparkiiig As such, proposed foundations are anticipated Provide foundation recommendations for on grade condition. Also, address potential differential settlement. Provide subgrade modulus reduction equation for size of footing. Provide subgrade modulus for on grade conditions. 5.8.2 Foundation Settlement 1) Update for actual foundation conditions. maximum differential static settlement is expected to be on the order of!72. inch over istáncofappróximaiely 40f6cfl Due to the absence of a shallow groundwater table and 2) Doe this conflict with design water elevation? maximum differential static settlement is expected to be on the order of Va inch over a distance of approximately 40 feet, Due to the absence of a shallow groundwatcrjabié and 5.8.4 Interior Concrete Slabs 1) Provide groundwatei elevation. It is our experience that the subterranean parking level slab on grade would not be considered a moisture-sensitive application. :}iowcvcr, due to the potential for groundwater, this slab on grade could be considered a moisture-sensitive application,. Therefore., the 5.10 Lateral Resistance and Earth Pressures Provide traffic surcharge design value. Provide dynamic thrust increment value as a function of H. PAE ~ PA 0 Tam Nguyen Jr., P.E. I Senior Project Engineer VCA Structural I Orange + Oakland 714.978.9780 ext. 217 I vcastructural.com I !L.YiI 1845 W. Orangewood Ave., Ste. 200 Orange, CA 92868 2