HomeMy WebLinkAboutCT 2017-0005; 800 GRAND AVENUE; WATER SIZING CALCULATIONS; 2018-12-17Water Sizing Calculations Village Walk Townhomes 341 - 347 Oak Avenue Carlsbad, California CT 2018-0005 ROW 2018-0573 DWG NO. 513-7 Prepared For: TMS Oak Investments 8, LLC 29250 Paseo Sedano San Juan Capistrano, CA 92675 951.801.0888 Prepared By: Surender Dewan, P.E. DMS Consultants, Inc. 12371 Lewis Street, Suite 203 Garden Grove, California 92840 714.740.8840 December 17, 2018 ----- '-1 'I'\ T FEB 2 52019 LAJ DE\1LOPMENT ¶rcDr L4 ,\Lr.i ' DMS CONSULTANTS, INC. CIVIL ENGINEERS VILLAGE WALK CARLSBAD WATER FLOW GENERATION (Ref. City of Carlsbad, Engineering Standard, Volume 2, Chapter 3) Average daily flow for multi family dwelling unit = 250 gpd Peaking factor = 2.90 Peak demand = 725 gpd Peak demand for 8 units = 725 x 8 = 5800 gpd = 4 gpm WATER SUPPLY FRICTION LOSS CALCULATION rsey'44etbrs %. "~__ @ HORIZON Em i es Z Features APPLICATIONS: For use in the measurement of potable water for applications where flow is consistently moderate to high. Designed for applications where accuracy is an essential part of maintaining revenue. The Horizon horizontal turbine meter is built to maintain accuracy over extended periods of use. CONFORMANCE TO STANDARDS: Horizon turbine meters have some of the widest flow ranges of any turbine meters on the market. All Horizon series turbine meters meet or exceed the latest performance and accuracy standards of AWWA C701. Maximum continuous flow rates may be exceeded by as much as 25% for intermittent periods. CONSTRUCTION: The Horizon consists of three basic parts: maincase; measuring insert: and register. Maincases are made of bronze. Measuring elements are thermoplastic with unique inlet and outlet straightening vanes. To simplify maintenance, the Horizon is designed to allow quick, easy, in-line exchange of the measuring element without remov- ing the maincase from the installation. Interchangeability of many parts within various sizes minimizes spare parts inventory and the Horizon comes standard with built-in strainer. REGISTER: Permanently sealed register has a unique seal and heat-treated glass to eliminate dirt, moisture infiltration and lens fogging. An integral tamper-proof locking feature is provided to prevent tampering of the register and calibration vane. The total- izing register has a straight-reading odometer type display: 3600 test circle with center sweep hand and a low flow (leak) detector. Standard gearing is used, making registers interchangeable by size. All Hersey Meter models have electronic meter reading systems available for increased reading efficiency (see Meter Reading Systems.) OPERATION: Water flows straight through the measuring element where it turns a rotor at a rate in direct proportion to the quantity of water flowing through the meter. The straight-through design allows high volumes to flow with a minimum of head loss. Retro ThrustO design extends the life of the meter by dividing wear between two points: during low flowthe tungsten carbide bearing in the rotor floats against a stainless steel shaft; during high flow a second tungsten carbide bearing gently moves back against another stainless steel shaft. During medium flow, the rotorfloats between both tungsten carbide bearings with sapphire bushings providing radial support for the rotor. STRAINER & TEST PORT: Standard Built-in Strainer. Test port is optional with spool piece. CONNECTIONS: ANSI Class 150 Flanges. 1 -1/2' NPT pipe threads on optional test outlet. Materials and Specifications D MODEL DESIGNATION .................................................HORIZON 11 SIZES ......................................... .. ......................................... 1-1/2,2" D STANDARDS .............Manufactured and tested to meet or exceed all applicable parts of ANSI/AWWA C701 class II Standard. fl SERVICE .....................................................Cold water measurement. D NORMAL OPERATING FLOW RANGE .... See Chart on page 3.2. D ACCURACY .....................................................See Chart on page 3.2. 1 PRESSURE LOSS ...........................................See Chart on page 3.2. D MAXIMUM WORKING PRESSURE ................................. 175 PSI D TEMPERATURE RANGE .................F to I OU°F water temperature 0 MEASURING ELEMENT ............Stainless Steel and Thermoplastic 0 REGISTER TYPE ...................Straight reading, permanently sealed, magnetic drive with low flow indicator. Remote Readings units optional. D MATERIALS .....................................Maincase - bronze UNS 84400; Casing bolts - Stainless steel ANSI B 18; Rotor - Thermoplastic; Rotor radial bearing - Sapphire: Rotor thrust bearings - tungsten carbide: Rotor bearing pivots - Stainless steel ANSI B 18; Magnet - rare earth/ceramic; Register box and lid - Thermoplastic or optional bronze: Standard strainer - Stainless steel: Spool piece with test outlet - bronze. 0 INSTALLATION ..............................................Horizontal or Vertical 0 METER CONNECTIONS ..................... 1-1/2' —2" ANSI Class 150 0 OPTIONS .......................................................AMR Reading Systems 3,1 Rev. 04-06 1. 309 C.) C.) C.) — rseyoAete. -fl ,r•__- orizontal TUrbinMtW' Meter iRegistrati on Meter Size Initial Dial* Capacity Initial Dial* Capacity 1-1/2 100 Gallons 100 Million 10 Cubic Feet 10 Million 2" 100 Gallons 100 Million 10 Cubic Feet 10 Million *Registration equal to one full revolution of the sweep hand. Flow Characteristics Meter Size Typical Low Flow (95% Minimum) Typical Operating Range (100%:t 1.5%) Maximum Continuous Operation Maximum Intermittent Flow 1-1/2 2 GPM 4 to 120 GPM 120 GPM 160 GPM 2" 2-1/2 GPM 4 to 160 GPM 160 GPM 200 GPM Performance* Dimensions & Weights 1-1/2" HORIZON RATE OF FLOW - U.S. GPM 'Performance curves are typical only and not a guarantee of performance ummmmmmammmmmmmmm - immmmmmmmmmmmmmmmmm ....••..a••••l• : isommmmmmmmmmmmmmwm.- immmmmmmmmmmwmmmmmm _ _•a•..._.......MMM - 2" HORIZON MESEEMEMENEEMEN ••uuuu••uuuuauuaa llm•UMUUUU••UUU•l• IIUUUUUUU•*•UU•U$UUNU•U IIUUSUUN•U••UUU•••U•U Nu•SRu•••Uu••ll mom 3.2 Rev. 04-06 Meter Size 1-1/2" 2" A Compact Length 9 10 AA Standard Length 13 17 B Height 7-3/4 7-3/4 C Centerline 1-3/4 2-1/8 D Holes 3/4 3/4 EWidth 6-1/8 6-1/8 F Flange 3/8 3/8 - Net Weight Compact -LBS 22 23 Net Weight Standard - LBS 26.5 32 - Certification \ ) Meters ccmolv with NSF/ANSIGI N5PANS1372. and conl'omis with lead content rsuirontanls fx iead-lretfptumbinq as defined by the U.S. Sale DlinklngWaler Act effective Jan 1. 2014 Temperature 105' F (40' C) max Pressure 150 psi operating max Materials 8ody/cplgs EcoBrass' Internals Magnet Engineered thermoplastic Alnico Accuracy +1-1.50/6 of reading within Qt-Qmex Sensor Reed switch Maximum Current 20 mA Maximum Voltage 24 Vdc or Vac Cable Length 12 (4m) std (2000 max run) .5 0 U .2 .5 0mm Or On Omnx Flow (gpm) e000rssS 0(CflZ8 muioy-Ieno DOmpOSuan IS IC55 rrien U. I15 ey welgru Size 062 = 5/8"xl/2" 075 = 518"x314" 100 = 3/4"xl" 100F = 1" 150 = 1 1/2" 200 = 2" www.flows.com IJUL Model Codes - How to Order GLF -075-R/IOF' Examples: GLF-075-RIIOG is a 3/4w meter with a pulse output (reed switch) sensor with a pulse rate of 10 gallons/pulse GLF-200 is a 2 meter with totalizer only Pulse Rate fif applicable) RJ20P = 20 pulse/gal only in 5/8"&3/4' RI10P = 10 pulse/gal only in 519&3/4 RI4P = 4 pulse/gal RJ2P = 2 pulse/gal R/I P = 1 pulse/gal R/5G = 5 gal/pulse R/10G = 10 gal/pulse R/50G = 50 gal/pulse R/IOOG= 100 gal/pulse Totalizer only meter would have nothing after the size designation 855-871-6091 I . S GLF Series NSF61!ANS372 Certified I1 çr Lead-FreeMulti-Jet Water Meters . GLF Series water meters use the widely accepted multi-jet principle, as a gear train drives the register totalizer dials. For pulse output meters, a reed switch sensor is attached to \ '' the outside of the lens and detects a magnet arm that has N. c• replaced one of the dial pointers. The reed switch output is / a dry contact closure and does not require power. \ Main Technical Data —Nomi—nal dlame ON 062- 518"x112" 075-518"x314" 100- 314"xl" IOOF. 1" 150-1 112' 200- 2" Maximumulowrale US gpm Omax 20 20. 30 50 100 160 Nominal flow rale US gpm On Transition flow rate US gpm 01 10 10 15 - 25 50 80 1 1 2 - 3 5 8 Minimum flow late US gpm Omin 0.25 0.25 0.5 1 0.75 1.5 1 2 Minimum reading US gallon 0.005 0.005 0.05 0.05 0.05 0.05 Accuracy Curve Specifications