HomeMy WebLinkAbout2725 STATE ST; ; FA160044; Permit8/15/22, 5:14 PM FA160044 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2725 STATE ST Permit Type: FALARM Parcel No: 2030540300 Lot #: 0 Reference No.: PC #: Permit No: FA160044 Status: ISSUED Applied 8/10/2016 Approved: 8/29/2016 Issued: 8/29/2016 Inspector: Project Title: CAMPFIRE INSTALL NEW FIRE ALARM SPRINKLER MONITORING SYSTEM TO MONITOR WATER FLOW, TAMPERS, ANSUL HOOD AND DUCT DETECTORS IN NEW RESTAURANT IN EXISTING ONE STORY SPRINKLERED BUILDING. INSTALL SMOKE DETECTOR ABOVE FACP SYSTEM TO BE AUTOMATIC (SPRINKLER MONITORING) AND MONITOR ANSUL HOOD SYSTEM. FA SYSTEM IS MONITORED BY CENTRAL STATION. OCCUPANCY IS LESS THAN 300 Applicant: 5 ALARM SECURITY 2794 LOKER AVE STE 109A CARLSBAD, CA 760-8097500 Owner: MARTIN DORIN&BILLIE REVOCABLE TRUST 01-10-94 P 0 BOX 546 FALLBROOK CA Fees ($) Add'I Fees ($iJ Total ($) Balance ($) 449 0 449 0 1/1 FA 160044 0 2725 STATE ST FC-6O3O', The Symbol of Protection RM CONTROL PANEL Features 30 Analog/Addressable Points in Any Combination 3.5 Amp Power Supply 2 NACS, Regulated, Rated at 3 Amps each Strobe Synchronization and System Wide Sync for Potter/ AMSECO®, Gentex®, Cooper Wheelock® and System Sensor® strobes System Wide Class A or B 99 Software Zones Large LCD and Keypad for Ease of Operation Cabinet will house 8 or 18 Ah batteries. Dead Front Cabinet for Clean Look Smoke Detector Drift Compensation and Maintenance Alerts NFPA 72 Compliant Smoke Sensitivity Test Built-In 1,000 Event History Buffer Optional two line DACT with UD- 1000 that can report General, Zone, or Point P-Link Communication Line for Annunciators and Accessories E-Mail System Status, Reports and Event Information Integrated, listed IP Communicator, Ethernet Port for Programming and Network Connectivity Electrical Specs: AC Mains Battery: 3.0 Amps @ 120 VAC 50/60 H2 • 130 mA Standby 2.0 Amps @240 VAC 50/60 H2 • 220mAAlarm Size(WxHxD): 16"x 17"x3 7/8" U1 NYC Fire Dept. L__JJ Certificate of Approval S735 7165-0328:0195 6157 Product includes a 5 year warranty Description The PFC-6030 is a versatile thirty point analog/addressable fire alarm control panel that utilizes the Potter/Nobmi device protocol that has a complete line of initiating and control devices. The SLC is capable of 50 ohms of resistance and does not require the use of twisted or shielded wire. The thirty (30) points may be any combination of smoke sensors, heat detectors or modules. The PFC-6030 has a metal cabinet with a key lock and a dead front standard. The cabinet will house 8 Ah or 18 An batteries. The large viewing window allows easy viewing of the LCD and the standard LEDs. The keypad allows easy operation and navigation of the system menu. All of the outputs are power limited, are power regulated and may be programmed for Potter/AMSECO, Gentex®, CooperWheelock® and System Sensor® strobe synchronization. The outputs may be configured for any combination of strobe brands and all will sync. The outputs also may be configured for door holder power, auxiliary power and constant power. The panel has auto-programming learn mode that will not affect the existing system when adding or deleting a device. The system is capable of 99 software zones, cross zoning and counting zones. The panel is fully programmed from a PC based software program that will work with Microsoft XP, Vista or Windows 7.0 operating systems. 'The PFC-6030 has an Ethernet connection for programming network connectivity and IP reporting communicatoi The system uses a simple patch cable for connecting a PC to the panel. In addition, the system may be connected to a building network and programmed while on the network. The system has a built in e-mail function and will send system E-mail reminders. The IP communicator is listed with the Sur-Gard III IP receiver. The panel will support P-Link devices which include: the RA-6075, RA-6500 and LED-16 Annunciators, RLY 5 Relay Module, SPG-1000 Se- rial Parallel Gateway (printer card), an FCB-1000 Remote Ethernet/l? connection, DRV-50 LED driver for 50 LEDs, PSN-1000 Remote Power Supplies (10 Amp) and FIB-1000 P-Link Fiber Interface Module. In addition, the panel'allows for the installation of the UD-1000 dual line telephone line digital alarm communicator transmitter (DACT). The UD-1000 is programmable for a single line or dual line and is compatible with Ademco's Contact ID or SIA DCS protocols. The complete system may be converted to Class A with a CA-6075 module. The CA-6075 provides the hardware necessary to convert the re- mote annunciators through the Potter P-Link connection protocol, the NACs and the SLC to Class A operation. Potter Electric Signal Company, LLC • St. Louis, MO • Cust Service: 866-956-1211 • Tech Support: 866-240-1870 • Canada: 888-882-1833• www.pottersignal.com PRINTED IN USA MKT. #8830024-REV A PAGE 1 OF 3 11/13 PFC-6030 (]2 "'''E' FIRE ALARM CONTROL PANEL The Symbol of Protection SLC Loop Accessories The control panel may be connected with up to thirty (30) addressable devices or modules in any combination. The SLC is not restricted by any special wire requirements and may be wired with any wire that complies with the NEC. SLC Loop Devices Device Description PSA Analog Photoelectric Smoke Detector with a listed obscuration of 1.02 to 3.83 percent per foot. PSHA Combination Analog Photo Electric Smoke/Heat Detector - a smoke detector with a listed obscuration of 1.02 to 3.83 percent obscuration and a fixed temperature 135° Fahrenheit heat detector FHA Analog Fixed Temperature Heat Detector that is selectable from 135° F to 185°F RHA Analog Rate or Rise Heat Detector that has a fixed temperature selection from 135°F and 174°F and also will alarm if the temperature increase 12-15°F in one minute DDA Addressable Duct Smoke Detector AB-6 6" round base that is mounted to an electrical box and wired for connection of one of the above sensors AB-4 4" round base that is mounted to an electrical box and wired for connection of one of the above sensors Affi Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop ARB Addressable Relay Base that contains two relays controlled by the SLC. One relay is rated at 8 amps at 240 VAC/30VDC and the other is rated at 2 amps 240 VAC/30 VDC ASB Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. The sounder follows the pattern sent to the device. Modules Device ' Description MCM Miniature Contact Module provides a small foot print contact module for mounting inside an enclosure. APS-SA Single Action Addressable Pull Station APS-DA Dual Action Addressable Pull Station SCM-4 Single Contact Module is a standard contact module with an LED that mounts into a 4" square electrical box. DCM-4 Dual Contact Module is a device that can monitor two distinct inputs with a single device or in a Class A mode. TRM-4 Twin Relay Module provides two form C relays that simultaneously active when the module is triggered by the control panel. Each relay is rated for 2 amps at 24VDC or 0.5 amps at 125VAC. MOM-4 Monitored Output Module switches monitored power and is activated by the control panel. CIZM-4 Conventional Input Zone Module is used to connect conventional smoke detectors. SCI Short Circuit Isolator interrupts a short on the SLC and prevents the short from affecting protected devices on the loop. P-Link Devices Device Description RA-6075 LCD/keypad remote annunciator with a metal enclosure and key lock. RA-6500 160 Character LCD. Keypad remote annunciator with metal enclosure and key lock. LED-16 LED remote annucniator capable of displaying alarms, supervisory, and trouble status for 16 zones. PSN- 1000 10p Intelligent power supply. RLY-5 5 Form C Relay Card. SPG- 1000 Serial/Parallel Printer Card, Optional Rack Mount. FCB- 1000 Fire Communications Bridge, 1 may be added for remote EP Communicator. FIB- 1000 I Fiber Interface Module, used in pairs to convert P-Link over multimode fiber, optional rack mount. PRINTED IN USA MKT. #8830024-REV A PAGE 2 OF 3 11/13 UF POTTER PFC-6030 The Symbol of Protection FIRE ALARM CONTROL PANEL SLC Circuit Diagram or IP Receiver Alarm Monitoring Station RA-6500 LCD Annunciator AE-8 8 Device Expansion Enclosure Conventional MA _ Snie Contact Miniature Contact Initiating Zone Module Module Module / PS 24 ot CO 12/24 _____ P32 iT Smoke Detector Carbon Monoxide Pull Station Detector PRINTED IN USA MKT. 8830024-REV A PAGE 3 OF 3 11/13