Loading...
HomeMy WebLinkAbout3200 CARLSBAD BLVD; ; FPC2019-0092; PermitPERMIT REPORT tC*ty of Carlsbad Fi:reiIe:r1niit Print Date: 07/27/2022 Job Address: 3200 CARLSBAD BLVD, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Commercial Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPC2019-0092 Status: Closed - Finaled Underground Fire Applied: 04/09/2019 Issued: 04/23/2019 Finaled Close Out: 09/26/2019 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: TAMARACK BEACH RESORT - REPLACE EXISTING 4" BACKFLOW Applicant: FPContractor: COSCO FIRE PROTECTION COSCO FIRE PROTECTION INC MATJORGENSEN 1075W LAMBERT RD 4990 GREENCRAIG LN BREA, CA 92821-2944 SAN DIEGO, CA 92123-1673 (858) 444-2000 (858) 444-2000 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $756.00 Total Payments To Date: $756.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1760-602-8561 1 I www.carlsbadca.gov Ff C--2-O (9 -ôo92 Hydraulic calculations using HydraCALC Cosco Fire Protection, Inc 4990 Greencraig Lane San Diego, CA 92123 858-444-2000 Job Name : Tamarack Beach Resort - Backflow Drawing FPI Location : 3200 Carlsbad Blvd Remote Area : I Contract : 10.CA_5430 Data File : 10.CA_5430 Tamarack Beach Resort Backflow.WXF Computer Programs by Hydratec Inc. Revision: 50.53.5 Cosco Fire Protection, Inc Tamarack Beach Resort - Backflow HYDRAULIC CALCULATIONS for Project name: Tamarack Beach Resort - Backflow Location: 3200 Carlsbad Blvd Drawing no: FPI Date: 4-9-19 Design Remote area number: I Remote area location: Base of Riser Proof Calc Occupancy classification: Ordinary Hazard Group I Density: .15 - Gpm/SqFt Area of application: 1500 - SqFt Coverage per sprinkler: 120 - SqFt Type of sprinklers calculated: 1/2 SSU QR No. of sprinklers calculated: 13 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 498.15 -GPM Type of system: Overhead Wet NFPA 13 Volume of dry or preaction system: N/A - Gal Water supply information Date: 01/14/19 Location: Carlsbad Blvd Source: City of Carlsbad Name of contractor: Cosco Fire Protection, Inc Address: 4990 Greencraig Lane / San Diego, CA / 92123 Phone number: 858-444-2000 Name of designer: M. Lovely Authority having jurisdiction: Carlsbad Fire Dept. Notes: (Include peaking information or gridded systems here.) Page 1 Date 4-9-19 @ 78.665-Psi Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Supp!y Curve C Cosco Fire Protection, Inc Page 2 Tamarack Beach Resort - Backflow Date 4-9-19 City Water Supply: Demand: Cl - Static Pressure : 83 Dl - Elevation : -0.866 C2 - Residual Pressure: 40 D2 - System Flow : 248.1 C2 - Residual Flow : 4450 D2 - System Pressure : 78.665 Hose ( Demand) : 250 D3 - System Demand : 498.1 Safety Margin : 3.586 150 - 140 130 120 R11° E10° s 90 "T c80 70 R 60 E 50 C2 40 30 20 10 50911000 1500 2000 2500 3000 3500 4000 4500 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Cosco Fire Protection, Inc Page 3 Tamarack Beach Resort - Backflow Date 4-9-19 Fitting Legend Abbrev. Name 1/ % 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 L NFPA 13 Long Turn Elbow 05 1 2 2 2 3 4 5 5 6 8 9 13 16 18 24 27 30 34 40 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zim Wilkins 375ADA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure I Flow Summary - STANDARD Cosco Fire Protection, Inc Page 4 Tamarack Beach Resort - Backflow Date 4-9-19 Node No. Elevation K-Fact Pt Actual Pn Flow Density Area Press Actual Req. BOR 0.0 67.43 na 248.15 UGI 0.0 67.51 na SF1 1.75 67.03 na BF2 1.75 77.85 na UG2 0.0 78.8 na TEST 2.0 78.67 na 250.0 The maximum velocity is 6.03 and it occurs in the pipe between nodes BOR and UGI Computer Programs by Hydratec Inc. Revision: 50.53.5 FinalCalculations: Hazen-Williams Cosco Fire Protection, Inc Page 5 Tamarack Beach Resort - Backflow Date 4-9-19 Nodel Elevi K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf BOR 0 +248.15 248.10 4 0.0 6.000 140 67.426 to 0.0 0.0 0.0 UGI 0 248.1 4.1 0.0 6.000 0.0135 0.081 Vel = 6.03 UGI 0 0.0 4 L 8.72 12.000 140 67.507 to 0.0 8.720 -0.758 BFI 1.750 248.1 4.1 0.0 20.720 0.0135 0.280 Vel = 6.03 BFI 1.750 0.0 4 2L 17.44 6.000 140 67.029 to Zim 0.0 17.440 10.500 * * Fixed Loss = 10.5 BF2 1.750 248.1 4.1 0.0 23.440 0.0135 0.317 Vel = 6.03 BF2 1.750 0.0 4 L 8.72 6.000 140 77.846 to 0.0 8.720 0.758 UG2 0 248.1 4.1 0.0 14.720 0.0135 0.198 Vel = 6.03 UG2 0 0.0 4 T 29.067 22.000 140 78.802 to C 2.907 31.974 -0.866 TEST 2 248.1 4.1 0.0 53.974 0.0135 0.729 Vel = 6.03 250.00 Qa = 250.00 TEST 498.10 78.665 K Factor= 56.16 Computer Programs by Hydratec Inc. Revision: 50.53.5 Accessories Air gap (Model AG) Repair kit (rubber only) O Thermal expansion tank (Model XI) O OS & Y Gate valve tamper switch (OSY-40) QT-SET Quick Test Fitting Set MODEL 375ADA with standard OS&Y MODEL 375ADA with BG option Attention: Model 375ADA (grooved body) and Model 375DA (flange body) have different lay lengths. ZURN Model 375ADA WILKINS Reduced Pressure Detector Assembly 7cc üô Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and back- pressure of contaminated water into the potable water supply. The Model 375ADA shall provide protection where a potential LEA/ FREE health hazard exists. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance 55F1AN5161 ASSE® Listed 1047 (2 1/2" 8") Options (with OS&Y gates) CSA® Certified B64.4 (2-1/2" - 8") (Suffixes can be combined) AWWA Compliant C550 0 - with OS & Y gate valves (standard) UL® Classified 0 L - less shut-off valves (grooved body connections) C-UL® Classified 0 LM - less water meter FM® Approved 0 - with remote reading meter Approved by the Foundation for Cross Connection El - with gallon meter (standard) Control and Hydraulic Research at the University of Southern u - with cu ft/min meter California. 0 G - with groove end gate valves NYC MEA 104-05-M 0 FIG - with flanged inlet gate connection and Meets the requirements of NSF/ANSI 61* grooved outlet gate connection *(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) 0 MS - with Integral Relief Valve Monitor Switch By-Pass Backflow Assembly 3/4" Model 975XLD 0 BG - with grooved end butterfly valves Materials 0 with integral supervisory switches Main valve body Ductile Iron ASTM A 536 0 BF - with flanged end butterfly valves Access covers Ductile Iron ASTM A 536 0 with integral supervisory switches Coatings FDA Approved fusion epoxy finish 0 P1 - with Post Indicator Gate Valve Internals Stainless steel, 300 Series 0 —509 - with AWWA C509 gate valves V NORYLTM Fasteners & Springs Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Sensing line Stainless steel, braided hose Features Sizes: 2 1/2*, 311* 4", 611, 811, 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel pipe) AWWA C606 (Flanged) ANSI B16.1 Class 125 *2 1/2" & 3" sizes use 4" body & reducer coupling Dimensions & Weights (do not include pkg.) WEIGHT MODEL WITH WITH 375ADA WITHOUT WITH OS&Y WITH OS&Y BUTTERFLY BUTTERFLY SIZE GATES GATES (GXF) GATES(GXG) VALVES VALVES (GXG) (GXF) in. mm lbs. kg lbs. kg lbs. kg lbs. kg lbs. I kg 21/2 65 112 50.8 214 97 206 93.5 154 70 164 74 3 80 111 50 231 104.8 221 100.3 156 71 169 77 4 100 98 45 252 114 226 103 146 66 168 76 6 150 151 69 387 176 357 162 225 102 255 116 8 200 321 146 797 362 1 773 351 465 211 511 232 10 250 374 170 1059 480 1 937 425 590 268 648 294 DIMENSION (approximate) - - MODEL 375ADA A WITH B LESS E E E WITH SIZE A BUTTERFLY GATE C 0 OS&Y OPEN OS&Y BUTTERFLY F H Relief Valve VALVES VALVES CLOSED VALVES discharge port: in. 'Tim in. 'Tim In. 'Tim in. mm in. 'Tim in. mm in. mm In. mm mm fl 2 1/2'- 6 - 2.75 sq. in. 21/2 65 351/8 892 321/8 816 201/8 511 41/2 114 9 229 163/8 416 137/8 352 81/4 210 11 279 95/8 247 8" -10" - 3.69 sq. in 3 80 361/8 918 33 838 /0178 511 41/2 1'1 9 229 187 479 155/8 397 81/2 /1-6 11 279 95?8 74-7- 4 100 381/4 972 331/4 845 197/8 505 41/2 114 9 229 223/4 578 181/4 464 9 229 11 279 95/8 2.47 6 150 471/4 1200 401/4 1022 257/8 657 51/2 140.101 2 267 301/8 765 233/4 603 101/4 260 123/8 314 3 _1 330 8 200 62 1575 55 1397 38 1/2 978 10 254 12 305 '37 3/4 959 291/4 743 12 305 153/8 391 175/16 440 10 250 645/8 1642 59 1491' 381/2 978 10 254 12 305 453/4 1162 353/8 899 13 330 153/8 391 171/8 435 Zurn Industries, LLC I Wilkins Rev. H 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 4/17 In Canada I Zurn Industries Limited Document No. BF-375ADA 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Patent No. 5, 913, 331 Product No. Model 375ADA wwwzurn,.00m I Pagel of 2 101.0 104 o. U) 69 00 Lu 35 U, U) In LU IL 0 138 a 104 S 69 w 35 w It 0 a. 4000 Flow Characteristics 0 Rated Flow (established by approval agencies) 4) (I, wO IX a. MODEL 375ADA 2-1/2" -3" (STANDARD AND METRIC) 0 6.3 12.6 FLOW RATES (us) 18.9 25.2 0 100 200 FLOW RATES (GPM) 300 400 MODEL 375ADA 4" & 6" (STANDARD & METRIC) FLOW RITES (us) 25.2 50.5 75.7 - -L--- ---- vi 15 0. 10 31.5 a 104 U) U) 69 o -j w 35 U) U) w 0 of Q. 500 0 400 800 1200 1600 FLOW RATES (GPM) MODEL 375ADA 8" & 10" (STANDARD & METRIC) FLOW RATES (us) 0.0 63.1 126.2 189.3 252.4 ro 20 91, 1000 2000 3000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for test- ing and maintenance. The installation shall be made so that no part of the unit can be submerged. I - iiU1pje'ii1 II 'II U DIRECTION OF FLOW r Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 21/2' 75 112 149 224 3 115 173 230 346 4 198 298 397 595 6" 450 675 900 1351 8" 780 1 1169 1559 1 2339 10" 1229 1 1843 2458 3687 12" 1763 1 2644 3525 5288 DIRECTION OF FLOW OUTDOOR INSTALLATION (MODEL 375ADA with BG option) INDOOR INSTALLATION (MODEL 375ADA with G option) Specifications The Reduced Pressure Detector Backf low Prevention Assembly shall be certified to NSF/ANSI 61, AS$E® Listed 1047, and supplied with full port OS & Y gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks and the relief valve shall be accessible for maintenance without removing the device from the line. The Reduced Pressure Detector Sackflow Prevention Assembly shall be a ZURN WILKINS Model 375ADA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2