Loading...
HomeMy WebLinkAbout155 CHESTNUT AVE; ; FPR2018-0153; Permit4II1IfIi 111fl41 Print Date: 07/27/2022 (äty of Carlsbad Fie1IieiFmiLt I---- Permit No: FPR2018-0153 Job Address: 155 CHESTNUT AyE, CARLSBAD, CA 92008-3107 Permit Type: FIRE-Construction Residential Work Class: Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check U: Plan Check U: Status: Closed - Finaled Single Family Fire Sprinkli Applied: 09/20/2018 Issued: 10/09/2018 Finaléd Close Out: 03/29/2021 Final Inspection: INSPECTOR: Fieri, Dominic Project Title: Description: KIM GUEST HOUSE INSTALL NEW SPRINKLER SYSTEM (12 HEADS) FPContractor: INNOVATIVE FIRE PROTECTION INC 8779 COTTONWOOD AVE, U STE 101 SANTEE, CA 92071-4457 (619) 593-8200 FEE AMOUNT FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $246.00 Total Payments To Date: $246.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 1 I www.carlsbadca.gov HYDRAULIC CALCULATIONS for Job Information Project Name: KIM GUESTHOUSE Contract No. : C - 16 711148 . City: CARLSBAD, CA 92008 Project Location: 155 CHESTNUTAVENUE Date: 9/14/2018 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECT, INC. Address: 8779 COTrONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: alex@ifpinc.net Name of Designer: ALEJANDRO Authority Having Jurisdiction: CALRDSBAD FIRE AUTHORITY Design Remote Area Name 1 Remote Area Location STUDIO Occupancy Classification Density (gpm/ft2) 0.051 Area of Application (ft2) 512 Coverage per Sprinkler (ft2) 256 Number of Calculated Sprinklers 2 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 30.9 Required Pressure at Source (psi) 62 Type of System Wet Volume - Entire System (gal) 22 gal Water Supply Information 05/31/2018 Date Location SITE 1 Source Notes File: Y:\ENGINEERING\3A.Project Fiies\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 1 Job: KIM GUESTHOUSE Node Labels: Off Pipe Labels: Off Diagram for Design Area: I (Ootimized Hydraulic SimDlified) File: Y:\ENGINEERING\3A.Project Files\071 64 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 2 Supply 1: 1 Flow (gpm) Pressure (psi) 0 78.3 500 73.3 Supply Analysis Job: KIM GUEST HOUSE Hydraulic Analysis for: I Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water @ 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lbs/It2) N/A for Hazen-Williams calculation. Water Supply Parameters Node atSource Static Pressure I Residual Pressure I I Flow i I Available I I Pressure I Total Demand I I Required Pressure (psi) I (psi) I (gpm) I I (psi) (gpm) I (psi) 1 78.3 73.3 500 78.3 30.9 62 Hoses Inside Hose Flow/ Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 25.9 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 25.9 Other Required Margin of Safety (psi) 0 1 - Pressure (psi) 62 1 -Flow(gpm) 30.9 Demand w/o System Pump(s) N/A File: Y:\ENGINEERING\3A.Project Files\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 3 Job: KIM GUESTHOUSE Hydraulic Analysis for: I Supply -a System Demand cj ,Aw ail ableA1 Source 100 F [.IlrAYI!J !1Li File: Y:ENGINEERlNG3A.Project Files\071 64 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright* 2002-2012 Tyco Fire Protection Products Page 4 Job: KIM GUEST HOUSE Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) SI Supply point #1 -Static 0 78.3 S2 Supply point #2 - Residual 500 73.3 Dl Elevation Pressure 0 12.6 D2 System Demand 30.9 62 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin I Pressure (psi) Flow (gpm) I Pressure (psi) I @ Flow (gpm) Supply 78.3 36 16.2 30.9 Open Heads Required Head Ref. Head Type Coverage K-Factor Calculated Density Flow Pressure Density Flow Pressure (ft2) (gpm/psil/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) Ki Overhead Sprinkler 256 4.9 0.05 12.8 7 0.051 13 7 K2 Overhead Sprinkler 256 4.9 0.05 12.8 7 0.051 13 7 File: Y:\ENGINEERING\3A.Project Files\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 5 Job: KIM GUEST HOUSE Hydraulic Calculations I Fluid Delivery Time Analysis Node Data Node# Type K-Fact. Discharge Coverage Tot. Pres. Req. Pres. Elev Hgroup Open/Closed Overdischarge Density Elev. Pres. Req. Discharge gpm/pslv2 gpm ft2 psi psi ft gpm gpm/ft2 psi gpm Ki Overhead Sprinkler 4.9 13 256 7 7 26 HEAD Open 0.2 0.051 -12.6 12.8 K2 Overhead Sprinkler 4.9 13 256 7 7 26 HEAD Open 0.2 0.051 -12.6 12.8 36 Node 6.9 27 NODE -13 37 Node 6.9 27 NODE -13 32 Node 9.6 27 NODE -13 13 Node 24.9 16 NODE -8.2 10-0 Node 28.7 11.75 NODE -6.4 10-I Node 34.1 11.25 NODE -6.2 09 Node 35.5 9 NODE -5,2 G5 Inside Hose 36 8 HOSE 5 -4.8 5 01 Node 36.1 8 NODE -4.8 03 Node 38.5 6 NODE -3.9 06 Node 47.2 -3 NODE 0 07-0 Node 47.7 -3 NODE 0 07-I Node 53.8 -3 NODE 0 08-0 Node 54.3 -3 NODE 0 08-I Node 58.3 -3 NODE 0 1 Supply -30.9 62 -3 SUPPLY . 0 File: Y:\ENGINEERING\3A.Project Files\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/1412018 Copyright© 2002-2012 Tyco Fire Protection Products Page 6 Job: KIM GUEST HOUSE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES I frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I K1 26 4.9 13 .75 1x(BM.Tee-Br)=3 1 150 7 36 27 13 0.874 3 0.0934 -0.4 4 0.4 36 27 -1 .75 1x(BM.Tee-Run)=1 21.21 150 6.9 32 27 12 0.874 1x(BM.Tee-Br)=3 12 0.081 0 2x(BM.90)=8 33.21 2.7 32 27 13.9 .75 1x(BM.Tee-8r)=3 18.17 150 9.6 13 16 25.9 0.874 lx(BM.90)=4 13.04 0.3372 4.8 lx(us.Tee-Br)=6.04 31.21 10.5 13 16 0 1 lx(coupling)=1.91 9.8 150 24.9 10-0 11.75 25.9 1.101 1x(BM.Tee-Run)=1 7.91 0.1095 1.8 1x(BM.90)=5 17.71 1.9 10-0 11.75 0 1 0.5 0 28.7 REST 10-1 11.25 25.9 0 0 10.2981 0.2 *** 0.5 5.1 10-I 11.25 0 1 lx(coupling)=1.91 2.25 150 34.1 09 9 25.9 1.101 1.91 0.1095 1 4.16 0.5 09 9 0 1 1 150 35.5 01 8 25.9 1.025 0 0.1552 0.4 1 0.2 01 8 5 1 lx(coupling)=1.35 3 150 36.1 03 6 30.9 1.025 lx(us.90)=2.7 4.05 0.2151 0.9 7.05 1.5 03 6 0 1.5 lx(coupling)=1.46 177.14 150 38.5 06 -3 30.9 1.598 2x(BM.90)=16 17.46 0.0247 3.9 194.6 4.8 06 -3 0 1 lx(coupling)=1.35 1 150 47.2 07-0 -3 30.9 1.025 1.35 0.2151 0 2.35 0.5 07-0 -3 0 1 0.5 0 47.7 WILKINS 950 07-1 -3 30.9 0 0 12.1434 0 *** 0.5 6.1 07-I -3 0 1 lx(coupling)=1.35 1 150 53.8 08-0 -3 30.9 1.025 1.35 0.2151 0 2,35 0.5 08-0 -3 0 1 0.5 0 54.3 METER2 08-I -3 30.9 0 0 8 0 *** 0.5 4 08-1 -3 0 1 15.25 150 58.3 1 -3 30.9 0.995 0 0.2486 0 15.25 3.8 1 62 File: Y:\ENGINEERING\3A.Project Files\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright ©2002-2012 Tyco Fire Protection Products Page 7 Job: KIM GUEST HOUSE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi1/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: 2 K2 26 4.9 13 .75 1x(BM.Tee-Br)=3 1 150 7 37 27 13 0.874 3 0.0935 -0.4 4 0.4 37 27 1 .75 1x(BM.Tee-Run)=1 14.12 150 6.9 32 27 13.9 0.874 2x(BM.Tee-Br)=6 11 0.1067 0 lx(BM.90)=4 25.12 2.7 32 9.6 Path No: 3 G5 8 5 1 lx(us.Tee-Br)=6.75 0.5 150 36 01 8 5 1.025 6.75 0.0074 0 7.25 0.1 01 36.1 Path No: 4 36 27 0 .75 lx(BM.Tee-Run)=1 10.83 150 6.9 37 27 1 0.874 1 0.0008 0 11,83 0 37 6.9 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 13.86 ft/s occurs in the following pipe(s): (13-32) '"K" Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: Y:\ENGINEERING\3A.Project Files\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 8 Job: KIM GUEST HOUSE Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: 1; Supply Name:1 S (N -r Flow, gp.m Pressure Loss Function Design Area: 1; BEP Ref.: 60 (WILKINS 950. Size = 1); Inlet Node: 07-I; Outlet Node: 01-0 Flow, gpm File: Y:\ENGINEERING\3A.Project Files\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 9 Job: KIM GUEST HOUSE Device Graphs Pressure Loss Function Design Area: 1; Valve Ref.: 5 tMETER2, Sue = 1; Inlet Node: 08-I; Outlet Node: 08-0 4 psi @ 3O9 U, Flow, gprn Pressure Loss Function Design Area: 1; Valve Ref.: 61 RESI, Size = 1); Inlet Node: 10-I; Outlet Node: 10-0 C C C <N F low, gpm File: Y:\ENGINEERING\3A.Project Files\07164 KIM RESIDENCE\07164 KIM RESIDENCE.dwg Date 9/14/2018 Copyright© 2002-2012 Tyco Fire Protection Products Page 10 1 01 SENJU SPRINKLER CO.,LTD. Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 49, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. These are decorative and fast response. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is in turn concealed above the ceiling. The cover plate has a flat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for the residential occupancies and it is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 131); wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents' escape or evacuation in case of fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AW\NA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or his representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085160 Date . Feb/09/2015 OPERATION Page 2 of 8 2—)'(6" (52mm) NPJ1/ Marking Lot Na. I Year of Manufacture I / —SIN SS8464 i— K—factor: K4,9 / Temperature Rating 1 62F/72'C E —UL Mark or 175F/79C I—Control No. 6P31 LNSF Mark NSF— Si —C ' RES SPKR ED Body (Copper Alloy) ® Deflector (Phosphorus Bronze) ED Casket (PTFE) ED Fusible Metal (Solder) ED Hoot Collector (Copper) 2- /8" (b 68mm) I (0 Cover Plate Assembly or 3-Y4" (83mm) or 2— %"square (068rnm) ] FIGURE 1. Model RC-RES K=4.9 Color Code Marking SIN SS8464 K—Iocor K4.9 Temperature Rating 152F/72'C or I751`/79C O —UL Mar k COVER PLATE SPRINKLER (lop view) (Bottom view) FIGURE 1-1. Marking (Color Code) TECHNICAL DATA Approvals: CIJLUS Listed, NSF-61 -G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175psi (12.1 bar) Discharge Coefficient (Nominal K-Factor): K4.9 GPM/psi112 (70.6 LPM/bar112) Temperature Rating: 1621 (72°C) Sprinkler with 1401 (60°C) Cover Plate 1751 (79°C) Sprinkler with 1621 (72°C) Cover Plate Color Code (Sprinkler) 1621 (72°C): Uncolored 1751 (79°1 White Color Code (Cover Plate) 1401 (6090): No Mark 1621 (72°C): White-Colored Mark Vertical Adjustment: 1/2 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figure 1 In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then, the Cover Plate is released at once. As a result, the Deflector drops down to the intended position. Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is recorded, internal components of the sprinkler to fall apart. This leads to allow the water flow to be distributed on the affected by fire area. (Ref. Figure 2) Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS (The figure is for illustrative purpose only) Document No. U085160 Date :Feb/09/2015 DESIGN CRITERIA Page 3 of 8 The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not coverage by the following instructions, should be submitted to Contact Company. Include sketches and technical details as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent and which take precedence over those specified in NFPA 13, 130, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radically outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as small as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided with the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13 for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D or 13R for the requirements relating to the prevention of possible activation of the Neat Responsive Element of Model RC-RES, due to exposure to a heat sources other than an actual fire. Precautionary Warnings for Corrosive Environments The Model RC-RES should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for the copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and leakage in the sprinkler system. Hydraulic Design Criteria The minimum required sprinkler flow rates for system designed to NFPA 13D or 13R are given in Table A as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of design sprinklers" as specified in NFPA 13D or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the followings; The flow rates given in Table A for NFPA 13D and 13R as a function of temperature rating and maximum allowable coverage area. Document No. U085160 Date Feb/09/2015 Page 4 of 8 A minimum discharge 0.1GPM/sq.ft. [4.07LPM/sq.mj over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage areas being protected by the four sprinklers. TABLEA. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Mode! S58464 Maximum Ordinary Intermediate Coverage Maximum Temperature Rating Temperature Rating Deflector Minimum Area Spacing 162T (72°C) 175'F (79°C) to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ft. Ceiling Type Ft. (m xm) (m) GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) Smooth 12x12 12 13 7.0 13 7.0 Ceilings (3.7x3.7) (3.7) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Inches. 14x14 14 13 7.0 13 7.0 (4.3x4.3) (4.3) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings per NFPA 16x16 16 13 7.0 14 8.2 13D,13R 8 (4.9x4.9) (4.9) (49.2) (0.48) (53.0) (0.57) or 13 Concealed (2.4) Installed 18X18 18 17 12.0 18 13.5 in beam 3/8 to (5.5x5.5) (5.5) (64.3) (0.83) (68.1) (0.93) 7/8 inches 20x20 20 21 18.4 - below (6.1x6.1) (6.1) (79.5) (1.27) - bottom of beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM/LPM from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R or 13 as applicable. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. Table A) INSTALLATION The Model RC-RES must be installed in accordance with the following instructions. NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation and until the ceiling installation is completed. The Protective Cap must be removed to place the sprinkler in service. Document No. U085160 Date . Feb/09/2015 Page 5 of 8 Use a torque of 7 to 14 ft.lbs (9.5 to 19.0111m) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting fora better fit. Installina Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inch (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Sprinkler Socket or Wrench & Socket Combination (Ref. Figure 4). The grooves of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with the 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Tolerance Limit of Ceiling Level" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Make a Space Here Do NOT Ave. )/4" (6.4mm) Over-Tighten ___________ SprinklerMm Y," (3.2mm) lerance Limit ErOf Ceiinq eve op (Ceiinv Mounting Lnh Surfoce Socket Wrench2-Y,(6Omm) _____ Ceiling Hole Diameter CORRECT INCORRECT FIGURE 3. INSTALLATION FIGURE 4 Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just comes in contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has come in contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening of the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot come in contact with the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6 Document No. U085160 Date :Feb/09/2015 Page : 6 of Sprinkler Head ctivea Step 1 Step 1 2 Hook by turning Step 3 Remover 4 Pull down FIGURE 5. PROTECTIVE CAP REMOVAL Cu cq lJj L1f ' 'Ceiling eiling~ ,Ceiling jo 104 Mounting Surface Deflector -I-I w Cover Plate Assembly L 2-/" (95 j or 3- /4" (0 83mm) or 2- 5/8-square (068mm) FIGURE 6 [INCORRECT IC0RRECT1 INCORRECT FIGURE 7. INSTALLATION (CORRECT OR INCORRECT) Document No. U085160 Date Feb/09/2015 CARE AND MAINTENANCE Page 7 of 8 The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40174°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not pull the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities and all affected by this action parties must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler systems to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must never be shipped or stored where the temperature exceeds 1001 /38°C. Automatic sprinkler must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units, as a result of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under Table A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verity that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing, its compliance with this documents, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Document No. U085160 Date . Feb/09/2015 ORDER PROCEDURE Page 8 of 8 When placing an order, please contact a local distributor with the following information (Model Name, Specify, Temp. and Finish). Sprinkler: Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162F (72°C) or 175F (79°C)) Cover Plate Assembly: 2-5/8 inch (68mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Wood grain Custom Color Custom Pattern 2-5/8' Round, 140°F 0 0 - - - 0 - 0 0 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - 0 0 3-1/4" Round, 162°F 0 - - - - - - 0 0 Tools for Installation of Model: RC-RES Socket for Model RC-RES Wrench & Socket for Model RC-RES Cap Remover RC Document No. U085160 Date Feb/09/2015 S." Fl Res 30, 49, 58 & 76 CCP Pendent Recessed HSW/F2 Res 44 & 58 Fl Res 44 SWC Fl Res 30, 49, 58 & 76 Fl Res 30, 49, 58 & 76 Recessed Pendent I Fl Recessed Pendent I FR Fl Res 58 HSWX Bulletin 135 Rev. M co ® Model F1 Residential Sprinklers for Design Density of .05 gpni/ft2 (D Model Fl Res Sprinklers engineered for the lowest flows to meet the minimum design density of .05 gpm4t2 Types: Fl Res 30Pendent Fl Res 30 Recessed Pendent/F2 Fl Res 30 Recessed Pendent/FP Fl Res 49 Pendent Fl Res 49 Recessed Pendent/Fl Fl Res 49 Recessed Pendent/FP Fl Res 58 Pendent Fl Res 58 Recessed Pendent/Fl Fl Res 58 Recessed Pendent/FP Fl Res 76 Pendent Fl Res 76 Recessed Pendent/Fl Fl Res 76 Recessed Pendent/FP Fl Res 30 CCP Pendent Fl Res 49 CCP Pendent Fl Res 58 CCP Pendent 16, Fl Res 76 CCP Pendent F1 Res 44HSW Fl Res 44 Recessed HSW/F2 Fl Res 58 HSW Fl Res 58 HSWX KRes58 HSWX Fl Res 58 HSW Recessed HSW/F2 Fl Res 44 SWC Listings & Approvals 1. Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Sprinklers for .10 Density: Refer to Bulletin 176 UL Listing Category Residential Automatic Sprinkler UL Guide Number VKKW Patents US Patent No. 6,516,893 applies to the Model Fl Res 49 & 58 Pendent Sprinklers US Patent No. 7,353,882 applies to Model Fl Res 44 & 58 HSW Sprinklers US Patent No. 7,784,555 applies to Model Fl Res 44 SWC Sprinklers Product Description Model Fl Res Pendent sprinklers (Figs. 1, 2, 3, & 4) are fast response sprinklers combining excellent durability, high sensitiv- ity glass-bulb and low profile decorative design. The Fl Res Horizontal Sidewall sprinklers (Figs. 5, 6 & 7) are equally attrac- tive when above ceiling piping cannot be used. The 3mm glass-bulb pendent sprinklers permit the efficient use of residential water supplies for sprinkler coverage in residential fire protection design. The low flow Fl Res sprinklers are specially engineered for fast thermal response to meet the sensitive fire protection applica- tion needs of the latest residential market standards (UL 1626 Standard). Upon tire conditions, rising heat causes a sprinkler's heat-sensitive element, glass bulb or link to actuate, releasing the waterway for water flow onto the deflector, evenly distributing the discharged water to control a fire. Technical Data: Thermal Sensor: Soldered Element (Link) or Nominal 3mm glass-bulb Sprinkler Frame: Brass Casting Sprinklers' Pressure Rating : 175 psi Factory Hydrostatically Tested to 500 psi Thread Size: ½' NPT (R1/2) K-Factor: 3.0(43.2) (Actual) - Fl Res 30 Pendent Sprinkler 4.9 (70.6) (Actual) - Fl Res 49 Pendent Sprinkler 5.8 (83.5) (Actual) - Fl Res 58 Pendent & HSW Sprinkler 7.6 (109)(Actual) - Fl Res 76 Pendent Sprinkler 4.4 (63) (Actual) - Fl Res 44 HSW Sprinkler Density: Minimum 0.05 gpmlft2 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model Fl Res 30, 49, 58 & 76 Pendent • Mod 'I ri iies 4, ou & to Kecessea rena lent/Fl Fl escutcheon, 3/4" (19mm) adjustment 2 1/4' HOLE DIA. - [57.2=,] - 1 15/1 6' DLI [49.2r,,,] I IX 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. - ADJUSTMENT 'ACE OF FITTING TO CEILING DIMENSION.' 3/8.'1 1/8' (Fl ESCUTCHEON) 3/8-7/8" (F2 ESCUTCHEON) /8" .1 2 27/32" 084, Application Model Fl Res Sprinklers are used for Residential Fire Pro- tection according to UL 1626 Standard*. For ceiling types: Smooth Flat Horizontal, or beamed, or sloped, in accordance with NFPA 13D, 13R, or 132013 editions. Be sure that orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of The Na- tional Fire Protection Association or the approving authority having jurisdiction. Installation Models Fl Res sprinklers are to be installed as shown. Model Fl, F2 and FP Escutcheons, illustrated herewith, are Escutcheon*, Fl or F2, Data: the only recessed escutcheons to be used with Model Fl Res sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res Pen- dent sprinklers use only the Model D sprinkler Wrench; for installing Models Fl Res Recessed Pendent, COP & SWC sprinklers use only the Model GFR2 sprinkler wrench; for in- stalling Model Fl Res Recessed HSW sprinklers use only the Model GFR2 Sprinkler Wrench. Use of wrenches other than those specified may damage these sprinklers. Install Fl Res 44 with a ceiling to deflector distance of 4" - 12". Flow arrow on deflector must point away from near wall and "Top" mark- ing must face ceiling. Type Adjustment "A" Face of fitting to ceiling Deflector Distance below bottom of beam Inch (mm) Inch (mm) Inch (mm) Inch (mm) Fl 3/4 (19.0) Mm. Recessed = 1/a(41,3) 3/,(9.5) 1/4 (44.4) Max, Recessed = /a(22.2) 11/8 (28.6) 1 (25.4) F2 1/2 (12.7) Mm. Recessed = 1/a (41.3) 3/,(9.5) 1/4 (44.4) Max. Recessed = 11/8 (28.6) 7/ (22.2) 11A(31.7) * Note: Escutcheons Fl or F2 may be used with Model Fl Res 49, 58 & 76 Recessed Pendent Sprinkler Model Fl Res 30 Recessed Pendent / F2 Fig. 1 Fig. 2 Technical Data: Fl Res 30 Pendent and Recessed Pendent (SIN R351 1) Thread Size I Nominal Orifice Inch (mm) I Max. Pressure psi (bar) I Sprinkler Temp. Rating I Max. Ambient Temp. I Actual K Factor I Sprinkler Length Inch (mm) OF °C I OF °C ½"NPT 21/64" (8.2) 175 (12) 155 I 68 79 I 100 38 3.0(43.2) 2,25 (57) I 175 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (iff68°C) Intermediate Temp. Rating (175°F/79°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (1/mm) Pressure 12 x 12(3,6 x 3,6) 12(3,6) 8(30,3) 7.0 (0,48) 8(30.3) 7.0 (0,48) Smooth ceilings 11/4 to 4(31.7 to 102) using F2 escutcheon. Beamed ceilings per NFPA 13D, 13R or 13 installed in beams 11/4 to 1,4 (31.7 to 44.4) using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 10(37,8) 11(0,76) 10(37,8) 11(0,76) 16 x 16(4,9 X 4,9) 16(4,9) 13(49) 18.8(1,3) 13(49) 18.8(1,3) For ceiling types refer to NFPA 13, 13R or 13D 2. Technical Data: F1 Res 49 Pendent and Recessed Pendent (SIN R3516) Thread Nominal Orifice I Max. Sprinkler Max. Actual Sprinkler Size Inch (mm) I Pressure Temp. Rating Ambient Temp. I K Length IOFOC OFIOC I psi (bar) Factor I Inch (mm) ½" NPT (R½) /16" (11) 175(12) 155 175 68 I 79 I 100 I 150 I 38 66 4.9 (70.6) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (1550 OC) (1750F,79°C) to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (mx m) Ft (m) GPM (Lithin) PSI (bar) GPM (1/mm) PSI (bar) Inch (mm) Ft (m) 12 x 12 (3,6 x 3,6) 12(3,6) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) Smooth Ceilings 1¼ to 4 (31.7 to 102) using F2 escutcheon. 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) 13 (49) 7.0 (0,48) 1 t 4(25.4 to 102) using Fl escutcheon, 16x 16(4,9x4,9) 16(4,9) 13(49) 7.0 (0,48) 13(49) 7.0(0,48) Beamed Ceilings per NFPA 13D, 138 or 13 installed in 8 (2,4) 18 x 18(5,5 x 5,5) 18(5,5) 17(64,3) 12(0,83) 17(64,3) 12(0,83) beams 1¼ to i/4 (31.7 to 14.4) using F2 escutcheon, 1 20 x 20(6,1 x 6,1) 20(6,1) 20(75,7) 16.7 (1,14) 20(75,7) 16,7(1,14)Ito 13/4(25.4 t044.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Ordinary Temp. Rating Intermediate Temp. Rating lop of Deflector Minimum Max. Coverage area Max. Spacing (1550F,8°C) (175°F1790C) to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) GPM (tfmin) PSI (bar) GPM (1/mm) PSI (bar) Inch (mm) Ft (m) 12 x 12(3,6 x 3,6) 12(3,6) 15(57) 9.4 (0,65) 15(57) 9.4 (0,65) Smooth Ceilings 4 to 8 (100 to 203) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(60,5) 10.6 (0,73) 16(60,5) 10.6 (0,73) 4 to 8 (100 to 203) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 12.0 (0,83) 17(64,3) 12.0 (0,83) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 8(2,4) 18 X 18(5,5 X 5,5) 18(5,5) 19(72) 15.0(1,0) 19(72) 15.0(1,0) 41/4 t08(108t0 203) using F2 escutcheon, 4 to 8(100 to 203) 20 x 20 (6,1 x 6,1) 20(6,1) 22 (83,2) 20.2 (1,4) 22 (83,2) 20.2 (1,4) using Fl escutcheon Technical Data: Fl Res 58 Pendent and Recessed Pendent (SIN R3513) Thread I Nominal Orifice I I I Max.I Sprinkler Max. I Actual I Sprinkler I Size Inch (mm) Pressure Temp. Rating I Ambient Temp. I K Factor Length I OF I °C OF I I psi (bar) i Inch (mm) ½" NPT (R½) I ½" (13) I 175 (12) 155 175 68 79 I 100 150 38 66 5.8 (83.5) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector Minimum Max. Coverage area Max. Spacing (155°F168°C) JiZ1FI79°C) to Ceiling Spacing Flow Pressure Flow Pressure Ft x Ft (mx m) Ft (m) Inch (mm) Ft (m) GPM (L/min) PSI (bar) GPM (1/mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) 16(61) 7.6(0,53) Smooth Ceilings 1114 to 4 (31.7 to 102) using F2 escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) 16(61) 7.6 (0,53) 1 t 4(25.4 to 102) using Fl escutcheon. 16 x 16(4,9 x 4,9) 16(4,9) 16(61) 7.6(0,53) 16(61) 7.6(0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in beams 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 19(72) 10,8 (0,75) 19(72) 10,8 (0,75) 11/4 to 13/4 (31.7 to 44.4) using F2 escutcheon, 1 t 13/4 (25.4 to 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) 22(83,3) 14.4 (1,0) 44.4) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D 3. El RES 49 PENDENT/EP Fig. 4 FP Escutcheon Data: "B" FP Position "A" Deflector Distance below bottom Inch (mm) of beam Inch (mm) Max. Recessed /i(11) 1/2 (12.7) Mm. Recessed 15/16(24) 1(25.4) Technical Data: Fl Res 76 Pendent and Recessed Pendent (SIN R7618) Thread Nominal Orifice Max. Sprinkler Max. K I Sprinkler Size I Inch (mm) Pressure Temp. Rating I Ambient Temp. Factor Length OF I °C OF °C I psi (bar) Inch (mm) 3/4' NPT (R3/4) I 17/32" (13.5) 175(12) 155 175 68 I 79 I 100 150 38 66 7.6 (109) 2.25 (57) Ordinary Temp. Rating Intermediate Temp. Rating Minimum Max. Coverage area Max. Spacing (1 55°Fi8°C) (175°F/790C) Top of Deflector to Ceiling Spacing 1 g Flow Pressure Flow GPM Pressure Ft x Ft (mx m) Ft (m) Inch (mm) GPM (1/mm) PSI (bar) (1/mm) PSI (bar) m 12 x 12 (3,6 x 3,6) 12(3,6) 21(795) 7.6 (0,53) 21(79,5) 7.6 (053) Smooth Ceilings 41/4 to 8(108 to 203) using F2 escutcheon. _____ 14x 14(4,3x4,3) 14(43) 21(79,5) 7.6(0,53) 21 (79,5) 7.6(0,53) 4t08(100t0203) using Fl escutcheon. 16x 16(4,9x4,9) 16(4,9) 21(79,5) 7.6(0,53) 21(79,5) 7,6(0,53) Beamed Ceilings per NFPA 130, 13R or 13 installed in 8(2,4) 18 X 18(5,5 X 5,5) 18(5,5) 21(79,5) 7.6(0,53) 21(79,5) 7.6(0,53) beams 41/4 to 8(108 to 203) us- ing F2 escutcheon, 4 to 8(100 20 X 20 (6,1 X 6,1) 20(6,1) 23 (87,1) 9.2 (0,63) 23 (87,1) 9.2 (063) ]to 203) using Fl escutcheon For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 30. 49. 58 & 76 CCP Pendent* Model Fl Res 30, 49, 58 & 76 Recessed Pendent/ FP * Not listed for corrosion resistance. FP push-on/thread-off escutcheon 2 5/8" [66.7mm] 0/A. 2 5/16" 0/A. HOLE IN CEILING [58.7mm] CUP r...........) 1"I/2" REDUCER CUP CEILING T X. FACE OFAG j O FACE OF CEILING DIMENSION 'A' COVER ADJUSTMENT HEIGHT 135F004E .mm Fl RES 30, 49, 58 & 76 CCP FEND. Fig. 3 Note: The Fl Res 76 will use a 1" x reducer. CCP Cover Plate Data: Cover Adjustment CCP Height "C,, Deflector Distance below bottom Inch (mm) Inch (mm) of beam Inch (mm) 1/2 (12.7) /16(24) 1/2 (13) - 1(25.4) /16 (7.9) 3/4 (19) 112 (13) 1/2" [13mm] MAX. FR ADJUSTMENT 2 5/8" 0/A. [66.7mm] -HOLE IN CEILING - 2 5/16" 0/A. r [58.7mm] - CUP T7 1" X 1/2" REDUCER 1 7/2[38.1mm] MAX. FACE OF FITTING TO FACE OF CEILING 0/MENSION Note: Sprinklers shown in Fig, 3 and Fig. 4 are not suitable for installation in ceilings which have positive pressure in the space above, Technical Data: F1 Res 30 CCP Pendent and Recessed Pendent/FP (SIN R3511) Thread Nominal Max. CCP Assembly I Max. Sprinkler Size Orifice I Pressure Temp. Rating I i Ambient Temp. K Length °F I °C I °C Inch (mm) psi (bar) Factor Inch (mm) I ½" NPT (R1/2) 21/64" (8.2) 175 (12) 135 57 100 38 3.0(43.2) 2.25 (57) Ordinary Temp. Rating Max. Coverage area Max. Spacing (155°F/68°C) Top of Deflector to Ceiling Minimum Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Spacing GPM (1/mm) PSI (bar) Ft (m) 12 X 12 (3,6 X 3,6) 12(3,6) 8(30,3) 7,0 (0,48) Smooth Ceilings 1/2 to 1(13 to 25.4) using CCP. ½ to 1(131025.4) using FP escutcheon. Beamed Ceilings per NFPA 13D, 13R or 13 installed in 8(2,4) 14 x 14 (4,3 x 4,3) 14(4,3) 11(37,8) 13.4 (0,92) beams ½ to 1(13 to 25.4) using CCP. ½ to 1(131025.4) using FP escutcheon. For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 49 CCP Pendent and Recessed Pendent/FP (SIN 3516) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (1550Fi8°C) Top of Deflector to Ceiling Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Spacing Ft (m) GPM (L/min) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 13(49) 7.0 (0,48) Smooth Ceilings ½ to 1(13 to 25.4) using 14 x 14 (4,3 x 4,3) 14(4,3) 13 (49) 7.0 (0,48) CCP. /2 to 1(13 to 25.4) using FP escutcheon, 16 x 16(4,9 x 4,9) 16(4,9) 14(53) 8.2 (0,56) Beamed Ceilings per NFPA 13D, 13R 0113 installed in beams ½ to 1(13 to 25.4) using 8(2,4) 18 x 18(5,5 x 5,5) 18(5,5) 18(68,1) 13.5 (0,93) CCP. V2 to 1(131025.4) using FP escutcheon, 20 x 20 (6,1 x 6, 1) 20(6,1) 20(75,7) 16.7(1,14) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 CCP Pendent and Recessed Pendent/FP (SIN R3513) Thread I Nominal l I Max. I I CCP Assembly I Max. I K Sprinkler I Size I Orifice I Pressure I Temp. Rating I Ambient Temp. Length I I I Inch (mm) I psi (bar) I °F I °C I °F I I °C Factor I I Inch (mm) ½" NPT (R 112) 1/2" (13) 175 (12) 135 57 100 38 5.8 (83.5) 2.25 (57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155- 8-C) Top of Deflector to Ceiling Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Spacing Ft (m) GPM (11mm) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(61) 7.6 (0,53) Smooth Ceilings ½ to 1(131025.4) using CCP. ½ to 1(131025.4) using FR escutcheon. 14 x 14(4,3 x 4,3) 14(4,3) 16(61) 7.6(0,53) 16 x 16 (4,9 x 4,9) 16(4,9) 16 (61) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams ½ to 1(131025.4) using CCP 8(2,4) 18 X 18(5,5 x 5,5) 18(5,5) 19(72) 10.8 (0,75) 1112 to 1(131025.4) using FR escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 22(83,3) 14.4(1,0) For Ceiling types refer to NFPA 13, 13R or 13D Nominal CCP Max. Max. Thread Orifice Assembly Ambient K Sprinkler Size Inch Pressure Temp. Temp . Factor Length (mm) psi (bar) Rating Inch (mm) OF °C OF ____ 1/2" NPT (RY2) L_( /16,, (11) I 175 (12) 135 I I 57 1 1001 I 38 4.9 (70.6) 1 2.25 (57) I _______ 5. 0 Model Fl Res 44 & 58 Recessed HSW/F2 F2 escutcheon, 1/2" (13mm) adjustment Technical Data: F1 Res 76 CCP Pendent and Recessed Pendent/FP (SIN R7618) Thread Nominal I Max. I I CCP Assembly Max. K Sprinkler I Size Orifice Pressure I Temp. Rating Ambient Temp. Factor I Length I OF I DC C Inch (mm) psi (bar) I I Inch (mm) 3/4" NPT (R3/4) 17/32" (13.5) 175(12) 135 57 1008 150 OF t66 7.6(109) 2.25(57) Max. Coverage Ordinary Temp. Rating Minimum area Max. Spacing (155. 80C) Top of Deflector to Ceiling Spacing Flow Pressure Ft x Ft (m x m) Ft (m) Inch (mm) Ft (m) GPM (Llmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 21(79,5) 7,6 (0,53) Smooth Ceilings ½ to 1(13 to 25.4) using CCP. ½ to 1(13 to 25.4) using FP escutcheon. 14 x 14 (4,3 x 4,3) 14(4.3) 21(79,5) 7.6 (0,53) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 7.6 (0,53) Beamed Ceilings per NFPA 13D, 13R or 13 installed in beams 1/2 to 1(13 to 25.4) using CCP. 8(2,4) 18 x 18 (5,5 x 5,5) 18(5,5) 22 (83,3) 8.4(0,58) 1/2 to 1(13 to 25.4) using FP escutcheon. 20 x 20(6,1 x 6,1) 20(6,1) 25(94,6) 10.8 (0,74) For Ceiling types refer to NFPA 13, 13R or 13D Model Fl Res 44 & 58 HSW FACE OF FITTING TO - I 1/4" WALL DIMENSION MW [31.8mm] -2 1/4" HOLE 0/A. L" A [57 2mm] DEFLECTOR 1" X 1/2" REDUCER [3.2mm]I CEILING TO DIMENSION - 1 15/6"OIA.ii - [49 2m 2 27/32" 0/A. - [722mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH SOSS. y" [13mm] -H 351006-0 ADJUSTMENT Fl RES 58 & 44 HSW/F2 Fig, 5 Technical Data: Fl Res 44 HSW & HSW/F2 (SIN R3531) "\ - Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Size Orifice Pressure Temp. Rating Temp. _________ Factor Length Inch (mm) psi (bar) Inch (mm) °FI°C ½" NPT 3/s" (10) 175 (12) 155 ______ ff 100 I 38 664.4(63) 2.45(62) (R½) ______ 175 150 Escutcheon, F2, Data: Face of Fitting Type Adjustment to wall Inch (mm) Inch (mm) F2 1/2(13) - '/16 11/16 (4.7 - 17.4) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°Fi80C) Intermediate Temp. Rating (175°F/790C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (11mm) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 12(45,4) 7.5(0,52) 12 (45,4) 7.5 (0,52) 4 to 6(100 to 152); ½ (13) recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2 (071) 14 (53,0) 10.2 (0,71) 16 x 16(4,9 x 4,9) 16(4,9) 16(60,6) 13.3 (0,92) 16 (60,6) 13.3 (0,92) 16 x 18(4,9 x 5,5) 16(4,9) 18(68,1) 16.8(1,16) 18(68,1) 16.8(1,16) 18 x 18(5,5 x 5,5) 18(5,5) 19(72,0) 18.7 (1,29) 19(72,0) 18.7(1,29) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4 (1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(53,0) 10.2 (0,71) 14(53,0) 10,2 (0,71) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14 x 14 (4,3 x 4,3) 14(4,3) 16(60,6) 13.3 (0,92) 16(60,6) 13.3(0,92) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,4) 15,0(1,04) 17(64,4) 15.0(1,04) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,7) 20.7 (1,43) 20(75,7) 20.7(1,43) 16 x 20(4,9 x 6,1) 16(4,9) 23(87,1) 27.4(1,89) 23(87,1) 27.4 (1,89) For Ceiling types refer to NFPA 13, 13R or 13D Technical Data: F1 Res 58 HSW & HS (SIN R3533) Escutcheon, F2, Data: Nominal Max. Sprinkler Max. Sprinkler Face of Fitting Thread Orifice Ambient K Length Adjustment Pressure Temp. Rating P. Factor Inch Inch (mm) to wall Type Size Inch Inch (mm) ___________ psi (bar) °F °C (mm) (mm) _____ /l6 - 11/16 ½" NPT 155 68 F2 1/2 (13) 1/2" (13) 175 (12) 5.8 (83.5) 2.45 (62) (4.7-17.4) (R½) 175 79 Ordinary Temp. Rating Intermediate Temp. Rating Top of Deflector to Minimum Max. Coverage area Max. Spacing (155°F/6) (1750F/79°C) Ceiling Flow Pressure Flow Pressure Ft x Ft (m x m) Ft (m) Spacing Inch (mm) Ft (m) GPM (Llmin) PSI (bar) 12 x 12(3,6 x 3,6) 12(3,6) 16(60,6) 7.6 (0,53) 16(60,6) 7.6(0,53) 4 to 6 (100 to 152); 14 x 14(4,3 x 4,3) 14(4,3) 18(68,2) 9.7 (0,69) 18 (68,2) 9.7 (0,69) 16 x 16(4,9 x 4,9) 16(4,9) 21(79,5) 13.2 (0,91) 21(79,5) 13.2 (0,91) ½ (13) recessed using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 25(94,7) 18.6 (1,28) 25(94,7) 18.6 (1,28) 8(2,4) 16 x 20(4,9 x 6,1) 16(4,9) 29(109,8) 25.0(1,73) 29(109,8) 25.0(1,73) 12 x 12(3,6 x 3,6) 12(3,6) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 6 to 12 (152 to 305); ½ (13) recessed 14 x 14(4,3 x 4,3) 14(4,3) 22(83,3) 14.4(1,0) 22(83,3) 14.4(1,0) 16 x 16(4,9 x 4,9) 16(4,9) 26(98,4) 20.1 (1,39) 26(98,4) 20.1 (1,39) using F2 escutcheon 16 x 18(4,9 x 5,5) 16(4,9) 31(117,4) 28.6(1,97) 31(117,4) 28.6 (1,97) For Ceiling types refer to NFPA 13, 13R or 13D 7. Model Fl Res 44 SWC* \ \ "S \ ,) I N - * Not listed for corrosion resistance. Thehniril Data- F1P A -qWr 1iPd Pqc21 e 10 12" [101.60*, ,* To 1/4" [31.75,*,*] M000*o,* Po** Of F,tt,*9 To W.11On,ons,00 PUSH ON COVER. THEN TURN TO ADJUST UNTIL TIGHT AGAINST WALL. "5 1/2" Rod- R000moNod;d Woll Hole 2 518" 2 5116- [8.%rn)44_. - [4 16) TURN COLLAR UNtIL TIGHT AGAINST SPRINKLER WRENCH BOSS. . I 21/32" (42o7J 35007 Fl RES 44 swc Fig. 6 Thread Nominal Max. Cover Temp. Max. Ambient K Sprinkler Size Orifice Pressure Rating Temp. Factor Length Inch (mm) psi (bar) Inch (mm) °F ½" NPT 3/8,100) 8"(10) 175(12) 135 (R½) 57 100 38 4.4(63) 2.45 (62) Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (155°F168°C) Top of Deflector to Ceiling Inch (mm) Minimum Spacing Ft (m) Flow GPM (lJmin) Pressure PSI (bar) 12 x 12 (3,6 x 3,6) 12(3,6) 13(49,2) 8.7(0,60) 4 to 6(100 to 152); 1/2(13) recessed using F2 escutcheon 8(2,4) 14 x 14(4,3 x 4,3) 14(4,3) 14(53,0) 10.2 (0,71) 16 x 16(4,9 x 4,9) 16(4,9) 17(64,3) 15.0 (1,1) 16 x 18(4,9 x 5,5) 16(4,9) 19(71,8) 18.7 (1,13) 16 x 20 (4,9 x 6, 1) 16(4,9) 23(87,1) 27.4(1,89) 12 x 12(3,6 x 3,6) 12(3,6) 14(52,9) 10.2 (0,71) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 14 x 14(4,3 x 4,3) 14(4,3) 15(56,7) 11.7(0,81) 16 x 16(4,9 x 4,9) 16(4,9) 18(68,1) 16.8(1,16) 16 x 18(4,9 x 5,5) 16(4,9) 20(75,6) 20.7(1,43) For Ceiling types refer to NFPA 13, 13R or 13D F:! Technical Data: Fl Res 58 HSWX (SIN RA3533) Thread Nominal Max. Sprinkler Max. Ambient K Sprinkler Sprinkler Size Orifice Pressure Temp. Rating Temp. Factor Length Identification Inch (mm) psi (bar) Inch (mm) Number (SIN) OF bc OF IOC Bulb Y2" NPT (R½) 1/2' (13) 175 (12) 155 175 I 68 79 100 150 38 5.8 (83.5) j 66 2.45(62) RA3533 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (1 55-17/68-C) Intermediate Temp. Rating (175°F/79°C) Top of Deflector to Ceiling Inch (mm) PSI (bar) Minimum Spacing Ft (m) Flow GPM (L/min) Pressure PSI (bar) Flow GPM (1/mm) Pressure 18 x 20 (5,5 x 6, 1) 18(5,5) 30(114) 26.8(1,85) 30(114) 26.8(1,85) 4t06(100t0 152); ½ (13) recessed using F2 escutcheon 8(2,4) 20 x 20(6,1 x 6,1) 20(6,1) 30(114) 26.8 (1,85) 30(114) 26.8 (1,85) 16 x 22(4,9 x 6,7) 16(4,9) 33(125) 32.4 (2,23) 33(125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 14 x 26(4,3 x 7,9) 14(4,3) 42(160) 52.4 (3,75) 42(160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); ½ (13) recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 38(144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4,9) 42(160) 52.4 (3,6) 42(160) 52.4 (3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9 (4,34) 46(174) 62.9 (4,34) For Ceiling types refer to NFFA 13, 13R or 130 Model Fl Res 58 HSWX (Bulb) FACE OF FITTING TO WALL DIMENSION 2 1/4" HOLE 0/A. [57.2mm] 7" X 1/2" REDUCER 1 75/76" [49.2mm] -7 11/16" MIN. [37.8mm] I CEILING TO 2mm] DEFLECTOR 'LJ DIMENSION 2 27/32" 0/A. [72.2mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS. Model KRes58 HSWX (Link) 735FG08 - ' 7/2" [73mm] ADJUSTMENT Fl RES 58 HSWX Fig. 7 91 Technical Data: KRes58 HSWX (RA3593) Thread Nominal Max. Max. Ambient K Sprinkler I Sprinkler Size i Orifice Pressure Tem p. Factor Length Identification Inch (mm) psi (bar) Inch (mm) I Number (SIN) ° F I Link 1/2 NPT 1/2' (13) 175 (12) 100 38 5.8 (83.5) 2.45 (62) RA3593 Max. Coverage area Ft x Ft (m x m) Max. Spacing Ft (m) Ordinary Temp. Rating (165- VC) Top of Deflector to Ceiling Inch (mm) Spacing Minimum Ft (m) Flow GPM (Umin) Pressure PSI (bar) 18 x 20 (5,5 x 6, 1) 18(5,5) 29(109) 25(1,72) 4t06(100t0 152); ½ (13) recessed using F2 escutcheon 8(2,4) 20x20(6,1 x6,1) 20(6,1) 30(114) 26.8(1,85) 16 x 22(4,9 x 7,3) 16(4,9) 33(125) 32.4 (2,23) 16 x 24 (4,9 x 7,3) 16(4,9) 38(144) 42.9 (2,96) 14 x 26(4,3 x 7,9) 14(4.3) 42(160) 52.4 (3,75) 18 x 20(5,5 x 6,1) 18(5,5) 35(133) 36.4 (2,5) 6 to 12 (152 to 305); ½(13) Recessed using F2 escutcheon 16 x 22(4,9 x 6,7) 16(4,9) 38(144) 42.9 (2,96) 16 x 24 (4,9 x 7,3) 16(4.9) 42 (160) 52.4 (3,6) 14 x 26(4,3 x 7,9) 14(4,3) 46(174) 62.9 (4,34) For Ceiling types refer to NFPA 13, 13R or 13D Maintenance Model Fl Res 30, 49, Fl Res 58, Fl Res 76 and Fl Res 44 Sprinklers should be inspected and the sprinkler sys- tem maintained in accordance with NFPA 25, 13, 13D, and 13R. Do not clean sprinkler with soap and water, Am- monia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Model Fl Res 30, 49 & 58 Pendent Sprinkler Specifications Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential pendent sprin- klers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area, Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's installation guide- lines and the applicable installation standard. Deflector- to-ceiling distance listing shall be 1" to 8" maximum, only for FiRes 49. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 3.0, 4.9 and 5.8. Standard finish: [Bronze] [Chrome- plated] [White Polyester] [Special finish— specify]. Resi- dential pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 49 & 58 Recessed Pendent/Fl, Model Fl Res 30, 49 & 58 Recessed Pendent/ F2, Model Fl Res 30,49 & 58 Recessed Pendent/ FP Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-f)] low flow residential recessed pen- dent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be installed in conformance with the manufacturer's in- stallation guidelines and the applicable installation stan- dard. Deflector-to-ceiling distance listing shall be 1" to 8" maximum, only for F1 Res 49. Sprinkler frame and deflec- tor shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded *DuPont Registered Trademark 10. or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (68°C)] [175°F (79°C)]. Sprinklers shall have a nomi- nal K-factor of 3.0, 4.9 & 5.8. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- spec- ify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjustment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with 1/2" adjustment (Model FP)]. Standard fin- ish shall be [brass][bright chrome] [white painted]. Resi- dential recessed pendent sprinklers shall be Reliable [Model El Res 30, 49 & 58 Recessed Pendent/F1] [Model Fl Res 30, 49 & 58 Recessed Pendent/F2] [Model Fl Res 30, 49 & 58 Recessed Pendent/FP] SIN R351 1, R3516 & R3513 (Bulletin 135). Model Fl Res 30, 49 & 58 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] [New York City MEA Approved (258-93-E)] low flow residential concealed sprinklers engineered to provide a minimum design den- sity of 0.05 gpm!ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprinklers shall be in- stalled in conformance with the manufacturer's installa- tion guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 1/2" NPT thread. Water seal as- sembly shall consist of a Teflon* coated Belleville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (68°C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color- specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 30, 49 & 58 CCP, SIN R3511, R3516 & R3513 (Bulletin 135). Model Fl Res 44, Fl Res 58 Horizontal Sidewall, Fl Res 58 HSWX & KRes58 HSWX Residential Sprinkler Specifications Sprinklers shall be [cULus Listed] low flow residential horizontal sidewall sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- *DuPont Registered Trademark leville spring washer with top-loaded extruded or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. The solder element (Link) version, the water seal consist of a cap with a bellville spring washer and a temperature rating of 165°F (74°C). The recessed assembly forthe HSWX (Bulb & Link) should be a steel two pieces escutcheon with 1/2" adjustment (Model F2) standard finish should be Bright Chrome and white paint- ed. The Fl Res 58 HSW is also available with low lead frame. Fl Res 58 HSW and HSWX sprinklers shall have a nominal K Factor of 5.8 and Fl Res 44 a nominal K factor of 4.4. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Special finish- specify]. Residential horizontal sidewall sprinklers shall be Reliable Model Fl Res 44, Fl Res 58, Fl Res 58 HSWX & Model KRes58 HSWX, SIN R3531, RA3533 & RA3593 (Bulletin 135). Model Fl Res 44 Recessed Horizontal Sidewall Sprinkler Use description for the Model Fl Res 44 horizontal side- wall sprinkler with the following modifications: Replace "horizontal sidewall sprinkler" with "recessed horizontal sprinkler." Add: Recessed escutcheon assembly shall be a steel, two-piece escutcheon with ½" adjustment (Model F2). Standard finish shall be [brass][bright chrome] [white painted] [Special finish- specify]. Residential recessed horizontal sidewall sprinklers shall be Reliable Model Fl Res 44/F2, SIN R3531 (Bulletin 135). Model Fl Res 76 Pendent Sprinklers shall be [cULus Listed] low flow residential pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 34" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of [155°F (680C)] [175°F (79°C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish- specify]. Residential pendent sprinklers shall be Reliable Model Fl Res 76, SIN R7618 (Bulletin 135). 11. Model Fl Res 76 Recessed Pendent/Fi, Model Fl Res 76 Recessed Pendent/F2, Model Fl Res 76 Recessed Pendent/FP Sprinklers shall be [cULus Listed] low flow residential recessed pendent sprinklers engineered to provide a minimum design density of 0.05 gpm/ft2 over the listed coverage area. Listed flows as specified by the manu- facturer's technical data sheets are to be used. Residen- tial sprinklers shall be installed in conformance with the manufacturer's installation guidelines and the applicable installation standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Water seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and hav- ing a temperature rating of [155°F (680C)] [175°F (790C)]. Sprinklers shall have a nominal K-factor of 7.6. Standard finish: [Bronze] [Chrome-plated] [White Polyester] [Spe- cial finish— specify]. Recessed escutcheon assembly shall be a steel, two-piece escutcheon [with 1/2" adjust- ment (Model F2)] [with 3/4" adjustment (Model Fl)] [of push-on and thread off design with 1/2" adjustment (Mod- el FP)]. Standard finish shall be [brass][bright chrome] [white painted]. Residential recessed pendent sprinklers shall be Reliable [Model Fl Res 76 Recessed Pendent/ Fl] [Model Fl Res 76 Recessed Pendent/F2] [Model Fl Res 76 Recessed Pendent/FP] SIN R7618 (Bulletin 135). Model Fl Res 76 CCP Pendent (Concealed) Sprinklers shall be [cULus Listed] low flow residential concealed sprinklers engineered to provide a minimum design density of 0.05 gpm!ft2 over the listed coverage area. Listed flows as specified by the manufacturer's technical data sheets are to be used. Residential sprin- klers shall be installed in conformance with the manufac- turer's installation guidelines and the applicable installa- tion standard. Sprinkler frame and deflector shall be of bronze frame construction having a 3/4" NPT thread. Wa- ter seal assembly shall consist of a Teflon* coated Bel- leville spring washer with machined or cold head cup with 3 mm glass bulb containing no plastic parts, and having a temperature rating of 155°F (680C). Cover plate assem- bly shall consist of a brass cover plate and copper alloy retainer flange. Method of attaching the cover plate to the sprinkler cup shall be a push-on and thread-off design allowing a ½" cover plate adjustment. Cover plate tem- perature rating shall be 135°F (57°C). A plastic protec- tive cap shall be provided and factory installed inside the sprinkler cup to protect the sprinkler from damage, which could occur during construction before the cover plate is installed. Standard cover plate finish: [White] [Custom Color— specify]. ]. Concealed pendent sprinklers shall be Reliable Model Fl Res 76 CCP, SIN R7618 (Bulletin 135). Finishes (1) Standard Finishes Sprinkler F1 F2 FP CoverPlates Escutcheons Bronze Brass White Painted Chrome Plated Bright Chrome Plated Chrome White and Black White Painted Polyester(') Coated Special Application Finishes Sprinkler Fl, F2, FP Escutcheons Electroless Nickel PTFE(Teflon6)i2i Electroless Nickel PTFE (Teflone) Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Chrome Dull Chrome Dull Other finishes and colors are available on special order, Consult factory for details. (2) cULus listed Corrosion Resistant Note: Paint or any other coating applied over the factory finish will void all approvals and warranties. Ordering Information Specify: Sprinkler Model Sprinkler Type Temperature Rating Sprinkler Finish Escutcheon Finish Cover Plate Finish *DuPont Registered Trademark The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices @ Paper J H (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 06/15 P/N 9999970235 1 •" aTApany b1 vsêmbfy 7 LCIF!CATON SUBMITTAL SHEET /49 1 H •i ¶-'---. FEATURES Sizes: 03/4" LI 1" LI 1-1/4 LI 1-1/2" LI 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 OPTIONS (Suffixes can be combined) LI - with full port QT ball valves (standard) LI L - less ball valves LI U - with union ball valves LI S - with bronze "Y" type strainer LI TCU - with test cocks "vertical" up LI V - with union swivel elbows (3/4" & 1") LI OSY - with OS & Y gate valves LI FDC - with fire hydrant connection (2" only) LI FT - with integral male 45° flare SAE test fitting APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (All sizes approved horizontal. Vertical approvals as listed below.) ASSE® Listed 1015 (vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical 1 1/4-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4") City of Los Angeles Approved (vertical 1-1/4"-2") NYC MEA 426-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series F ACCESSORIES El Repair kit (rubber only) C3 Thermal expansion tank (Model WXTP) F El QT-SET Quick Test Fitting Set LI Test Cock Lock (Model TCL24) D DIMENSIONS & WEIGHTS (do not include pkg.) ____ B_________ A G DIMENSIONS (approximate) WEIGHT MODEL A UNION LESS WITH B LESS BALL SIZE A BALL C D E F G BALL BALL VALVES VALVES VALVES VALVES mm in mm in. mm in. I mm in. Imm in. Immmmmm in. Imm lbs kg jlbs. I kg 3/4 20 11 1/4 286 121/2 318 7 178 11/2 38 3 76 31/2 89 3 76 15 381 5 2.3 7 1 3.2 1 25 12 1/4 311 137/8 353 7 178 1 1/2 38 3 76 31/2 89 3 76 173/4 451 8 3.6 12 5.4 11/4 32 151/2 419 181/2 470 109/16 268 2 51 31/289 41/2 114 41/2 114 211/254616 7.3 22 10 11/2 40 17 1/8 435 191/8 486 109/16 268 2 51 31/2 89 41/2 114 41/2 114 223/4 578 16 7.3 22 10 2 50 181/414601 20 508 109/16 268 2 51 3 1/2 89 41/2 114 41/2 114 251/8 638 16 7.3 28 12.7 __ _____ Page 1 of 2 WILKINS a Zurn company, 1747 commerce Way, Paso Robles, CA 93446 Phone:805-238-7100 Fax:805-238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11_2 Phone: 905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http://www.zurn.com 3.2 6.3 9.5 12.6 15.8 103 .CL 69 0 (I) -J w 35 (I, U) w 50 100 150 200 250 ° 15 10 OL 0 gzi FLOW CHARACTERISTICS MODEL 950XL 3/4", 1", 1 1/4",11 1/2" & 2" (STANDARD & METRIC) FLOW RATES (us) 1.26 2.52 3.8 5.0 15 ______ .__314" (20mm) 1" (2mm)_ 10 Uj to 0 - 0 20 40 60 80 FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) Capacity thruSchedule 40 Pipe Pipesize 5ft/sec 7.5ftlsec lOft/sec 15ft/sec 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 1 63 1 95 52 78 1 105 1 167 TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. DIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be acces- sible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a WILKINS Model 950XL. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone: 805-238-7100 Fax:805-238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11_2 Phone: 905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http://www.zurn.com Page 2 of 2 .TL Item Description 1 Manifold Body, Male Thread x Male Thread 2 Inline Check Valve, Spring Loaded 3 Flow Switch with Retard 4 Drain Valve, with optional pressure relief valve 5 Pressure Gauge, 0-300 psi National Fire Products, LLC R ES I - RISERTM The RESI-RISERTM is a pre-assembled, compact, attractive fire sprinkler riser unit for residential sprinkler systems in accordance with NFPA 13, 13R and 13D. The RESt-RISERTM manifold is manufactured as a one- piece casting that is air-tested for leaks. Raised lettering on both sides allows the RESI-RISERTM to be installed to the right or left and easily identifies the flow direction and Test and Drain outlet. Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring. The flow switch has dual SPDT switches and a retard of 0-90 seconds. An optional "all in one" cost saving combination Pressure Relief Valve/Test and Drain Valve is available. The RESl-RISERTM unique design gives the ability to be installed within standard 2 x 4 frame construction. Every size RESI-RISERTM fits within a 2 x 4 wall framed at 16 inches on center. Technical Data Sizes: 1", 1'A", 1W', and 2" Style: Thread x Thread Listing: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi Pressure Relief Valve/Test and Drain US Patent # 6,076,545 RESI-RISERTM Size Chart ______ ________ Description 1" 11/4" 1W' 2" Height* 13" 13" 13" 13" Width** 10-3/4" 11-1/2" 12" 12-1/2- Depth 3-1/2" 3-1/2" 3-1/2" 3-1/2- Drain Size 1/2" 1" 1" 1" Dimensions include all spacing needed to operate drain valve and remove flow switch cover * Without check valve ** With or without pressure relief valve NORTH COUNTY FIRE PROTECTION DISTR 330 S. MAIN AVE. FALLBROOK, CA 92028 01-W i © National Fire Products, LLC (800) 528-7978 Pressure Loss Tables Pressure Loss in 1" Resi-Riser 12 Pressure Relief/Test and Drain How it Works Normal Position - Static Pressure 0 10 15 20 25 30 35 40 Flow (gpm) Pressure Loss in 1-1/4" Resi-Riser Relieving Pressure Exceeding 175 psi ==-....... ~oommammom I S 0 10 15 20 25 30 35 40 45 50 55 60 Flow (gpm) Pressure Loss in 1-1/2" Resi-Riser 10 Manual Open - Drain or Flow Switch Test 0 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 Flow (gpm) Pressure Loss in 2" Resi-Riser Locked Closed for Hydrostatic Test 6 0 15 25 35 45 55 65 75 85 95 Flow (gpm) © National Fire Products, LLC (800) 528-7978