HomeMy WebLinkAbout3068 STATE ST; ; FPC2018-0402; PermitPrint Date: 08/15/2022 Job Address: 3068 STATE ST, CARLSBAD, CA 92008-2367 Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2032970600 Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Permit No: FPC2018-0402 Status: Closed - Finaled Applied: 12/11/2018 Issued: 06/26/2019 Finaled Close Out: 02/24/2020 4City ot PI!RXT REPORT Carlsbad Fjeeirmjjt Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check#: INSPECTOR: Salcedo, Felix Plan Check #: Fieri, Dominic Maldonado, Adalmira Project Title: Description: STATE AND OAK -STATE MIXED USE 30- REVISED PLANS FOR NEW FIRE SPRINKLERS (627 HEADS) 4 STORIES Applicant: FPContractor: TITAN FIRE PROTECTION INC TITAN FIRE PROTECTION INC CHRISTIAN MCGREGOR 1341 DISTRIBUTION WAY, # STE 14 1341 DISTRIBUTION WAY, # STE 14 VISTA, CA 92081-8843 VISTA, CA 92081-8843 (760) 295-3436 (760) 295-3436 FEE AMOUNT FIRE NFPA 13 System> 100 heads (includes 1 riser) $858.00 FIRE Plan Resub (3rd&Subsequent Submittal/hr) $204.00 Fire Use Fee Manual $711.00 Total Fees: $1,773.00 Total Payments To Date: $1,773.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 1 760-602-8561 f I www.carlsbadca.gov A I TAV 4 FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION HYDRAULIC CALCULATIONS STATE MIXED USE 30 3068 STATE ST. 3080 STATE ST, 542 OAK AVE. CARLSBAD, CA. 92008 CONTRACT NO. 18433 Ccl NEW CALCS FOR FP-3 ROOF LEVEL: -AREA 7 -AREA 8 2880 Scott Street, Suite 105 - Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page No. 165 ¼. CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: State Mixed Use 30 SR#: PC15-0016 (Assigned upon plan submittal) PROJECT ADDRESS: 542 Oak Avenue CITY: Carlsbad PHONE: ( 951 ) 302-2163 (Titan Fire Protection) FAX NUMBER: (760) 295-3437 Largest Building (ft.2): 44,835 Sprinkled? YES Construction Type: Ill-B SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Oak Avenue at State Street TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 85 PSI Hydrant Number (if applicable):H60783 Elevation of test: 44 Feet Main Size: 12 INCH Pressure Zone 241 Feet Date/Time of Test 1 Pot Tube Reading EsponthngFkw GPM Total Flow: 5,725 GPM Residual Pressure 34 PSI Atpeakdemand, this water system is capable of providing a fire flow discharge at 20 psi of 6,700 gpm. However, this flow exceeds the District's maximum pipeline velocity of 10 fps. The maximum fire flow that meets both the velocity and pressure criteria is 5,725 gpm.There was no specific request forfire flow from the Client or Fire Department. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: j Name: Jennifer R. Mael, P.E. Eng. Lic. No. (if applicable): C69606 Signature Date: 08/24/2018 'I - \,- Fire Flow Test \ Location H60783 . 1\.S. ) / \\ \\ V Legend w_Hydrant Pipe ZONE -241 #165 State Mixed Use 30 (542 Oak Avenue) - Fire Flow Analysis ZURN Madeg 3500& wiiis Double Check Detector Assembly FOR REFENECE ONLY (BY OTHERS) Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Model 350DA shall provide protection where a potential health hazard does not exist. Incorporates metered by-pass to detect leaks and unauthorized water use. Standards Compliance (Sizes 2 1/2" - 10° Horiz. & Veil.) (12 Horizontal Only) ASSE® Listed 1048 (Sizes 2 1/2 thru 12') GSA® Certified B64.5 (Sizes 2 1/2' thru 8', & 12) AWWA Compliant C510 (Sizes 2 1/2" thru 12"), and C550 UL® Classified (Sizes 2 1/2' thru 12") C-UL® Classified (Sizes 2 1/2' thru 12") FM® Approved (Sizes 2 1/2" thru 10') NYC MEA 147-99-M Vol 4 (2-1/2' - 10) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (Sizes 2 1/2" thru 12") Meets the requirements of NSF/ANSI 61* *(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) By-Pass Backf low Assembly 3/4" Model 950XLD Materials Main valve body Ductile Iron ASTM A 536 Access covers Ductile Iron ASTM A 536 Coatings NSF Approved fusion epoxy finish Internals Stainless steel, 300 Series NORYLTM Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLIM Springs Stainless Steel, 300 Series Features Sizes: 2 1/2', 3", 4", 6", 8', 10", 12° Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) Options (Suffixes can be combined) o - with OS & Y gate valves (standard) J L - less shut-off valves (flanged body connections) 0 LM - less water meter - with remote reading meter - with gallon meter (standard) El CFM - with cu ft meter El CMM - with cu meter meter El G - with groove end gate valves O FG - with flanged inlet connection and grooved outlet connection El P1 - with Post Indicator Gate Valve O GF - with flanged inlet connection and grooved outlet connection El BG - with grooved end butterfly valves with integral monitor switches (2 1/2' - 10°) El -509 - with AWWA C509 gate valves Accessories El Repair kit (rubber only) El Thermal expansion tank (Model XI) El OS & Y Gate valve tamper switch (OSY-40) Attention: Model 350DA (flange body) and Model 350ADA (grooved body) have different lay lengths. T I I MODEL 350DAG SHOW.N JABOVE DIMENSION (prc"tnate) WEIGHT MODEL A BLESS E E E wWITH LESS OS&Y OS&Y BUTTERFLY 350DA A GATE C D OS&Y OS&Y F SRJTOFF GATE GATE VALVES SIZE BUTTERFLY VALVES OPEN CLOSED BUTTERFLY VALVES GROOVED VALVES VALVES VALVES VALVES FLANGED GROOVED in. mm in. I mm in. I mm in. rnm in. mm in. mm in. I mm in. mm in. I mm in. mmIbs. I kg lbsjIbs.jIbsj 2165 31 78728711157/840333/495 9229173144511531839181/421031/289 6831 178 81 160 73 140 64 3 32817247/840334959229201M4 328 63V268 68 890 150 68 120 54 4 100 37 58 56328835249449229222572446492296 152 106 48 296t34282819086 6 0443M1737SS 956 232597615210226730V2775241I46 1218 135 820060341543537/81369373/495910254123053794028it2724123058V22i6374170850386802364548249 _10_ 250633/41619577/8147037314 959 10254 12 30545SS 9343/48831333081/221640418312225541156524792 21 359 12 300 66 1/4,1683, n/a n1a 38 965 12 305 53 1346401/2 1029 n1a n/a 87/8 226 -3 210 n/a Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zum Industries limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. H Date: 1/17 Document No. BF-350DA Patent No. 5,913,331 Product No. Model 350DA Page 1 of 2 00010CTNE VERTICAL INSTALLATION Flow Characteristics 0.0 15 8 -j 0 jCl) U). (I) 0. I 2111 400 600 Sn RATES (GPM) /A[•JI](STANDARD 11 METRIC) 4 'P 31.5 63.1 FLOW RATES (11s) 94.6 126.1 15 ."----. - - E - ------ I fill ('III' !I[•)p] d I .y_' '1;1/I [s4 1IL S S rr -- -- - L -- ____ -- -- -- -,--------------- 0 500 1000 1500 2000 2500 3000 3500 4000 FLOW RATES (GPM) MODEL 350DA 21/2", 3" & 4" (STANDARD & METRIC) FLOW RATES (Vs) 12.6 25.2 37.9 0 Rated Flow (established by approval agcocics) 50.5 103 69 B 800 157.7 IV.) 169 —J- i 1 :, J0 0. 4500 103 (I) (0 0 —J 69 340 0 Q. 2000 2500 220.8 252.4 283.9 Typical Installation Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for test- ing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 21/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 1 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 12" 1763 2644 3525 5288 OUTDOOR INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be certified to NSF/ANSI 61, ASSE® Listed 1048, and supplied with full port gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536), the seat ring and check valve shall be NorylTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The first and second check valves shall be accessible for maintenance without removing the device from the line. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 350DA. Zum tndust,ies, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zum Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 - - - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name 18433 State Mixed Use Building : FP-2 Location : LEVEL 1 System : 1 Contract : 18433 Data File : 18433 State Mixed Use -FP Design WIWXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 1 18433 State Mixed Use Date 12-4-18 HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: LEVEL 1 Drawing no: FP-2 Date: 9-12-18 Design Remote area number: 1 Remote area location: RETAIL Occupancy classification: OH 2 Density: .2 - Gpm/SqFt Area of application: 1533 - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: QR SSU K5.6 No. of sprinklers calculated: 15 In-rack demand: - GPM Hose streams: 250 - GPM Total water required (including hose streams): 656.87 -GPM Type of system: WET Volume of dry or preaction system: -Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) @ 63.17-Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 State Mixed Use Date 12-4-18 City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 5.089 C2 - Residual Pressure: 25.5 D2 - System Flow : 406.875 C2 - Residual Flow : 5725 02 - System Pressure : 63.171 Hose (Demand ) : 250 03 - System Demand : 656.875 Safety Margin : 12.400 150 140 130 120 R11° E10° C1 S90 S 80 U 70 D2 R 60 E 50 40 30 20 ..Qi.. I I I I . 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. 18433 State Mixed Use Page Date 3 12-4-18 Fitting Legend Abbrev. Name 1/ 3/4 1 11/4 11/z 2 2,4 3 31/3 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 I NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with '. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 State Mixed Use Date 12-4-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 19 55.75 5.6 21.56 na 26.0 0.2 130 7.0 47 55.75 22.66 na 48 55.75 22.93 na 49 55.75 23.85 na 50 55.75 25.72 na 51 55.75 31.41 na 52 55.75 31.48 na 53 55.75 31.78 na 54 55.75 32.48 na 11 55.75 36.89 na TR1 54.0 41.37 na BR1 46.0 46.17 na S2 54.33 42.78 na S3 54.33 45.69 na T 54.33 50.05 na BFI 42.0 56.4 na BF2 42.0 63.75 na POC 42.0 63.92 na UGI 42.0 63.99 na TEST 44.0 63.17 na 250.0 59 55.75 5.6 21.61 na 26.03 0.2 130 7.0 60 55.75 22.71 na 61 55.75 22.98 na 62 55.75 23.91 na 63 55.75 25.78 na 64 55.75 5.6 21.82 na 26.16 0.2 130 7.0 65 55.75 22.93 na 66 55.75 23.21 na 67 55.75 24.14 na 68 55.75 26.03 na 69 55.75 5.6 21.82 na 26.16 0.2 130 7.0 70 55.75 5.6 21.87 na 26.19 0.2 130 7.0 71 55.75 5.6 22.08 na 26.31 0.2 130 7.0 72 55.75 5.6 22.7 na 26.68 0.2 130 7.0 73 55.75 5.6 22.75 na 26.71 0.2 130 7.0 74 55.75 5.6 22.97 na 26.84 0.2 130 7.0 75 55.75 5.6 24.48 na 27.71 0.2 130 7.0 76 55.75 5.6 24.54 na 27.74 0.2 130 7.0 77 55.75 5.6 24.78 na 27.87 0.2 130 7.0 78 55.75 5.6 26.0 na 28.55 0.2 130 7.0 79 55.75 27.3 na 80 55.75 27.57 na 81 55.75 28.61 na 82 55.75 5.6 26.25 na 28.69 0.2 130 7.0 83 55.75 5.6 27.24 na 29.23 0.2 130 7.0 The maximum velocity is 15.13 and it occurs in the pipe between nodes 54 and 11 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 State Mixed Use Date 12-4-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 19 26.00 1.08 T 5.0 1.000 21.556 K Factor =5.60 to 120.0 0.0 5.000 0.0 47 26.0 0.1835 0.0 6.000 1.101 Vel = 9.11 47 0.0 1.728 0.0 14.580 22.657 to 120.0 0.0 0.0 0.0 48 26.0 0.0186 0.0 14.580 0.271 Vel = 3.56 48 26.16 1.728 0.0 13.670 22.928 to 120.0 0.0 0.0 0.0 49 52.16 0.0674 0.0 13.670 0.922 Vel = 7.14 49 26.67 1.728 0.0 12.920 23.850 to 120.0 0.0 0.0 0.0 50 78.83 0.1447 0.0 12.920 1.870 Vel = 10.78 50 27.71 1.728 T 8.0 14.490 25.720 to 120.0 0.0 8.000 0.0 51 106.54 0.2528 0.0 22.490 5.685 Vel = 14.58 51 0.0 3.314 0.0 7.170 31.405 to 120.0 0.0 0.0 0.0 52 106.54 0.0106 0.0 7.170 0.076 Vel = 3.96 52 106.68 3.314 0.0 7.750 31.481 to 120.0 0.0 0.0 0.0 53 213.22 0.0383 0.0 7.750 0.297 Vel = 7.93 53 107.18 3.314 0.0 8.600 31.778 to 120.0 0.0 0.0 0.0 54 320.4 0.0813 0.0 8.600 0.699 Vet = 11.92 54 86.48 3.314 T 15.0 19.920 32.477 to 120.0 0.0 15.000 0.0 11 406.88 0.1265 0.0 34.920 4.417 Vet = 15.13 11 0.0 4.31 2E 20.0 45.580 36.894 to 120.0 2T 40.0 60.000 0.758 TR1 406.88 0.0352 0.0 105.580 3.714 Vel = 8.95 TR1 0.0 4.31 E 10.0 8.000 41.366 to 120.0 T 20.0 30.000 3.465 BR1 406.88 0.0352 0.0 38.000 1.336 Vet = 8.95 BRI 0.0 4.31 0.0 6.370 46.167 to 120.0 0.0 0.0 -3.608 S2 406.88 0.0353 0.0 6.370 0.225 Vel = 8.95 S2 0.0 4.31 3E 30.0 20.620 42.784 to 120.0 B 12.0 62.000 0.0 S3 406.88 0.0352 T 20.0 82.620 2.906 Vel = 8.95 S3 0.0 4.31 5E 50.0 53.830 45.690 to 120.0 T 20.0 70.000 0.0 1 406.88 0.0352 0.0 123.830 4.356 Vet = 8.95 T 0.0 4.31 2E 20.0 8.830 50.046 to 120.0 0.0 20.000 5.340 BFI 406.88 0.0352 0.0 28.830 1.014 Vel = 8.95 BF1 0.0 8.27 2E 47.88 10.000 56.400 to 140.0 Zid 0.0 47.880 7.283 * * Fixed Loss = 7.283 BF2 406.88 0.0011 0.0 57.880 0.064 Vet = 2.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 State Mixed Use Date 12-4-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BF2 0.0 7.68 T 52.887 41.000 63.747 to 150.0 G 6.044 86.130 0.0 POC 406.88 0.0014 2F 27.199 127.130 0.178 Vet = 2.82 POC 0.0 9.42 T 75.553 52.000 63.925 to 150.0 0.0 75.553 0.0 UG1 406.88 0.0005 0.0 127.553 0.066 Vet = 1.87 UG1 0.0 11.2 0.0 209.490 63.991 to 150.0 0.0 0.0 -0.866 TEST 406.88 0.0002 0.0 209.490 0.046 Vet = 1.33 250.00 Qa = 250.00 656.88 63.171 KFactor= 82.65 59 26.03 1.08 T 5.0 1.000 21.610 K Factor =5.60 to 120.0 0.0 5.000 0.0 60 26.03 0.1838 0.0 6.000 1.103 Vet = 9.12 60 0.0 1.728 0.0 14.580 22.713 to 120.0 0.0 0.0 0.0 61 26.03 0.0187 0.0 14.580 0.272 Vet = 3.56 61 26.19 1.728 0.0 13.670 22.985 to 120.0 0.0 0.0 0.0 62 52.22 0.0676 0.0 13.670 0.924 Vet = 7.14 62 26.71 1.728 0.0 12.920 23.909 to 120.0 0.0 0.0 0.0 63 78.93 0.1451 0.0 12.920 1.875 Vet = 10.80 63 27.74 1.728 T 8.0 14.490 25.784 to 120.0 0.0 8.000 0.0 52 106.67 0.2533 0.0 22.490 5.697 Vet = 14.59 0.0 106.67 31.481 K Factor= 19.01 64 26.16 1.08 T 5.0 1.000 21.818 K Factor= 5.60 to 120.0 0.0 5.000 0.0 65 26.16 0.1857 0.0 6.000 1.114 Vet = 9.16 65 0.0 1.728 0.0 14.580 22.932 to 120.0 0.0 0.0 0.0 66 26.16 0.0188 0.0 14.580 0.274 Vet = 3.58 66 26.31 1.728 0.0 13.670 23.206 to 120.0 0.0 0.0 0.0 67 52.47 0.0682 0.0 13.670 0.932 Vet = 7.18 67 26.84 1.728 0.0 12.920 24.138 to 120.0 0.0 0.0 0.0 68 79.31 0.1464 0.0 12.920 1.892 Vet = 10.85 68 27.88 1.728 T 8.0 14.490 26.030 to 120.0 0.0 8.000 0.0 53 107.19 0.2556 0.0 22.490 5.748 Vet = 14.66 0.0 107.19 31.778 KFactor= 19.01 69 26.16 1.08 T 5.0 1.000 21.815 K Factor 5.60 to 120.0 0.0 5.000 0.0 48 26.16 0.1855 0.0 6.000 1.113 Vet = 9.16 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 18433 State Mixed Use Date 12-4-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 26.16 22.928 K Factor = 5.46 70 26.19 1.08 T 5.0 1.000 21.869 K Factor =5.60 to 120.0 0.0 5.000 0.0 61 26.19 0.1860 0.0 6.000 1.116 Vel = 9.17 0.0 26.19 22.985 K Factor = 5.46 71 26.31 1.08 T 5.0 1.000 22.080 K Factor = 5.60 to 120.0 0.0 5.000 0.0 66 26.31 0.1877 0.0 6.000 1.126 Vel = 9.21 0.0 26.31 23.206 K Factor= 5.46 72 26.68 1.08 T 5.0 1.000 22.695 K Factor = 5.60 to 120.0 0.0 5.000 0.0 49 26.68 0.1925 0.0 6.000 1.155 Vel = 9.34 0.0 26.68 23.850 K Factor= 5.46 73 26.71 1.08 T 5.0 1.000 22.751 K Factor = 5.60 to 120.0 0.0 5.000 0.0 62 26.71 0.1930 0.0 6.000 1.158 Vel = 9.35 0.0 26.71 23.909 K Factor= 5.46 74 26.84 1.08 T 5.0 1.000 22.970 K Factor = 5.60 to 120.0 0.0 5.000 0.0 67 26.84 0.1947 0.0 6.000 1.168 Vel = 9.40 0.0 26.84 24.138 K Factor= 5.46 75 27.71 1.08 T 5.0 1.000 24.482 K Factor = 5.60 to 120.0 0.0 5.000 0.0 50 27.71 0.2063 0.0 6.000 1.238 Vel = 9.70 0.0 27.71 25.720 K Factor= 5.46 76 27.74 1.08 T 5.0 1.000 24.542 K Factor = 5.60 to 120.0 0.0 5.000 0.0 63 27.74 0.2070 0.0 6.000 1.242 Vel = 9.72 0.0 27.74 25.784 K Factor= 5.46 77 27.88 1.08 T 5.0 1.000 24.777 K Factor = 5.60 to 120.0 0.0 5.000 0.0 68 27.88 0.2088 0.0 6.000 1.253 Vel = 9.76 0.0 27.88 26.030 K Factor= 5.46 78 28.55 1.08 T 5.0 1.000 25.996 K Factor = 5.60 to 120.0 0.0 5.000 0.0 79 28.55 0.2182 0.0 6.000 1.309 Vel = 10.00 79 0.0 1.728 0.0 12.200 27.305 to 120.0 0.0 0.0 0.0 80 28.55 0.0221 0.0 12.200 0.270 Vel = 3.91 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 8 18433 State Mixed Use Date 12-4-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 80 28.70 1.728 0.0 12.880 27.575 to 120.0 0.0 0.0 0.0 81 57.25 0.0800 0.0 12.880 1.031 Vel = 7.83 81 29.22 1.728 T 8.0 14.530 28.606 to 120.0 0.0 8.000 0.0 54 86.47 0.1718 0.0 22.530 3.871 Vel = 11.83 0.0 86.47 32.477 K Factor = 15.17 82 28.69 1.08 T 5.0 1.000 26.254 K Factor = 5.60 to 120.0 0.0 5.000 0.0 80 28.69 0.2202 0.0 6.000 1.321 Vel = 10.05 0.0 28.69 27.575 K Factor = 5.46 83 29.23 1.08 T 5.0 1.000 27.240 K Factor = 5.60 to 120.0 0.0 5.000 0.0 81 29.23 0.2277 0.0 6.000 1.366 Vel = 10.24 0.0 29.23 28.606 K Factor 5.47 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 18433 State Mixed Use -FP Design Building : FP-2 Location : LEVEL 1 System 1 Contract : 18433 Data File : 18433 State Mixed Use -FP Designr&àWXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 18433 State Mixed Use -FP Design Date HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: LEVEL 1 Drawing no: FP-2 Date: 12-6-18 Design Remote area number: 1 Remote area location: PARKING Occupancy classification: OH 2 Density: .15 - Gpm/SqFt Area of application: 1582 - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: QR SSU K5.6 No. of sprinklers calculated: 18 In-rack demand: - GPM Hose streams: 250 - GPM Total water required (including hose streams): 611.52 - GPM @ 66.57 - Psi Type of system: WET Volume of dry or preaction system: - Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor. 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 State Mixed Use -FP Design Date City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 5.089 C2 - Residual Pressure: 25.5 D2 - System Flow : 361.52 C2 - Residual Flow : 5725 D2 - System Pressure : 66.576 Hose ( Demand ) : 250 D3 - System Demand :611.52 Safety Margin : 9.111 150 140 130 p120 R11° E10° 90 s 80 U 70 R60 D E 50 40 - 30 -- 62 20 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 3 18433 State Mixed Use -FP Design Date Fitting Legend Abbrev. Name 1/ % 1 11/4 1½ 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 .12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 State Mixed Use -FP Design Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 18 55.75 12.39 na 17 55.75 5.6 12.25 na 19.6 0.15 130 7.0 2 55.75 5.6 12.25 na 19.6 0.15 130 7.0 3 55.75 5.6 12.35 na 19.68 0.15 130 7.0 4 55.75 5.6 12.64 na 19.91 0.15 130 7.0 5 55.75 5.6 13.36 na 20.47 0.15 130 7.0 6 55.75 5.6 14.77 na 21.52 0.15 130 7.0 87 55.75 16.64 na 20 55.75 12.39 na 34 55.75 5.6 12.26 na 19.61 0.15 130 7.0 28 55.75 5.6 12.26 na 19.61 0.15 130 7.0 29 55.75 5.6 12.36 na 19.69 0.15 130 7.0 30 55.75 5.6 12.65 na 19.92 0.15 130 7.0 31 55.75 5.6 13.38 na 20.49 0.15 130 7.0 32 55.75 5.6 14.8 na 21.55 0.15 130 7.0 89 55.75 16.68 na 38S 55.75 5.6 12.13 na 19.5 0.15 130 7.0 39S 55.75 5.6 12.53 na 19.82 0.15 130 7.0 40S 55.75 5.6 13.42 na 20.52 0.15 130 7.0 90S 55.75 15.1 na 23S 55.75 5.6 12.16 na 19.53 0.15 130 7.0 24S 55.75 5.6 12.61 na 19.89 0.15 130 7.0 25S 55.75 5.6 13.57 na 20.63 0.15 130 7.0 88S 55.75 15.32 na 21 53.67 13.34 na 38 53.67 13.47 na 39 53.67 13.89 na 40 53.67 14.81 na 90 53.67 16.0 na 22 53.67 13.35 na 23 53.67 13.5 na 24 53.67 13.97 na 25 53.67 14.96 na 88 53.67 16.22 na 7 55.75 24.82 na 8 55.75 24.91 na 9 54.42 26.44 na 12 54.42 28.27 na 10 53.08 39.38 na 11 55.75 42.81 na TR1 54.0 46.55 na BR1 46.0 51.09 na S2 54.33 47.66 na S3 5433 50.0 na 1 54.33 53.5 na BF1 42.0 59.65 na BF2 42.0 67.21 na POC 42.0 67.35 na UG1 42.0 67.4 na TEST 44.0 66.58 na 250.0 The maximum velocity is 13.63 and it occurs in the pipe between nodes 32 and 89 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 State Mixed Use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18 -21.49 1.728 T 8.0 2.450 12.388 to 120.0 0.0 8.000 0.0 17 -21.49 -0.0130 0.0 10.450 -0.136 Vel = 2.94 17 19.60 1.728 T 8.0 2.450 12.252 K Factor= 5.60 to 120.0 0.0 8.000 0.0 2 -1.89 -0.0002 0.0 10.450 -0.002 VeI•= 0.26 2 19.60 1.728 0.0 10.690 12.250 K Factor = 5.60 to 120.0 0.0 0.0 0.0 3 17.71 0.0092 0.0 10.690 0.098 Vel = 2.42 3 19.68 1.728 0.0 8.000 12.348 K Factor =5.60 to 120.0 0.0 0.0 0.0 4 37.39 0.0364 0.0 8.000 0.291 Vel = 5.12 4 19.91 1.728 0.0 9.000 12.639 K Factor= 5.60 to 120.0 0.0 0.0 0.0 5 57.3 0.0803 0.0 9.000 0.723 Vel = 7.84 5 20.47 1.728 0.0 10.000 13.362 K Factor = 5.60 to 120.0 0.0 0.0 0.0 6 77.77 0.1411 0.0 10.000 1.411 Vel = 10.64 6 21.52 1.728 0.0 8.420 14.773 K Factor = 5.60 to 120.0 0.0 0.0 0.0 87 99.29 0.2219 0.0 8.420 1.868 Vel = 13.58 87 0.0 1.728 T 8.0 28.870 16.641 to 120.0 0.0 8.000 0.0 7 99.29 0.2219 0.0 36.870 8.181 Vel = 13.58 0.0 99.29 24.822 K Factor = 19.93 20 -21.25 1.728 T 8.0 2.450 12.394 to 120.0 0.0 8.000 0.0 34 -21.25 -0.0128 0.0 10.450 -0.134 Vel = 2.91 34 19.61 1.728 0.0 10.340 12.260 K Factor = 5.60 to 120.0 0.0 0.0 0.0 28 -1.64 -0.0001 0.0 10.340 -0.001 Vel = 0.22 28 19.60 1.728 0.0 10.690 12.259 K Factor =5.60 to 120.0 0.0 0.0 0.0 29 17.96 0.0094 0.0 10.690 0.100 Vel = 2.46 29 19.69 1.728 0.0 8.000 12.359 K Factor =5.60 to 120.0 0.0 0.0 0.0 30 37.65 0.0369 0.0 8.000 0.295 Vel = 5.15 30 19.92 1.728 0.0 9.000 12.654 K Factor = 5.60 to 120.0 0.0 0.0 0.0 31 57.57 0.0810 0.0 9.000 0.729 Vel = 7.88 31 20.49 1.728 0.0 10.000 13.383 K Factor =5.60 to 120.0 0.0 0.0 0.0 32 78.06 0.1421 0.0 10.000 1.421 Vel = 10.68 32 21.54 1.728 0.0 8.420 14.804 K Factor =5.60 to 120.0 0.0 0.0 0.0 89 99.6 0.2233 0.0 8.420 1.880 Vel = 13.63 89 0.0 1.728 T 8.0 28.870 16.684 to 120.0 0.0 8.000 0.0 8 99.6 0.2232 0.0 36.870 8.228 Vel = 13.63 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 State Mixed use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 99.60 24.912 K Factor= 19.96 38S 19.50 1.191 T 5.0 1.580 12.125 K Factor= 5.60 to 120.0 0.0 5.000 0.901 38 19.5 0.0669 0.0 6.580 0.440 Vel = 5.62 0.0 19.50 13.466 K Factor 5.31 39S 19.82 1.191 T 5.0 1.580 12.533 K Factor =5.60 to 120.0 0.0 5.000 0.901 39 19.82 0.0690 0.0 6.580 0.454 Vel = 5.71 0.0 19.82 13.888 K Factor= 5.32 40S 20.52 1.191 T 5.0 1.580 13.424 K Factor= 5.60 to 120.0 0.0 5.000 0.901 40 20.52 0.0734 0.0 6.580 0.483 Vet = 5.91 0.0 20.52 14.808 K Factor = 5.33 90S 0.0 1.191 T 5.0 1.580 15.099 to 120.0 0.0 5.000 0.901 90 0.0 0.0 0.0 6.580 0.0 Vet = 0 0.0 0.0 16.000 K Factor =0 23S 19.53 1.191 T 5.0 1.580 12.157 K Factor= 5.60 to 120.0 0.0 5.000 0.901 23 19.53 0.0670 0.0 6.580 0.441 Vet = 5.62 0.0 19.53 13.499 K Factor = 5.32 24S 19.89 1.191 T 5.0 1.580 12.610 K Factor =5.60 to 120.0 0.0 5.000 0.901 24 19.89 0.0693 0.0 6.580 0.456 Vet = 5.73 0.0 19.89 13.967 K Factor= 5.32 25S 20.63 1.191 T 5.0 1.580 13.569 K Factor =5.60 to 120.0 0.0 5.000 0.901 25 20.63 0.0742 0.0 6.580 0.488 Vet = 5.94 0.0 20.63 14.958 K Factor= 5.33 88S 0.0 1.191 T 5.0 1.580 15.319 to 120.0 0.0 5.000 0.901 88 0.0 0.0 0.0 6.580 0.0 Vet = 0 0.0 0.0 16.220 K Factor =0 21 20.21 1.728 T 8.0 2.450 13.344 to 120.0 0.0 8.000 0.0 38 20.21 0.0117 0.0 10.450 0.122 Vet = 2.76 38 19.50 1.728 0.0 10.340 13.466 to 120.0 0.0 0.0 0.0 39 39.71 0.0408 0.0 10.340 0.422 Vet = 5.43 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 18433 State Mixed Use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 39 19.83 1.728 0.0 10.690 13.888 to 120.0 0.0 0.0 0.0 40 59.54 0.0861 0.0 10.690 0.920 VeI= 8.15 40 20.51 1.728 0.0 8.000 14.808 to 120.0 0.0 0.0 0.0 90 80.05 0.1490 0.0 8.000 1.192 Vet = 10.95 90 0.0 1.728 T 8.0 56.270 16.000 to 120.0 2E 8.0 16.000 -0.325 9 80.05 0.1490 0.0 72.270 10.766 VeI = 10.95 0.0 80.05 26.441 KFactor= 15.57 22 22.53 1.728 T 8.0 2.450 13.350 to 120.0 0.0 8.000 0.0 23 22.53 0.0143 0.0 10.450 0.149 VeI = 3.08 23 19.53 1.728 0.0 10.340 13.499 to 120.0 0.0 0.0 0.0 24 42.06 0.0453 0.0 10.340 0.468 Vet = 5.75 24 19.88 1.728 0.0 10.690 13.967 to 120.0 0.0 0.0 0.0 25 61.94 0.0927 0.0 10.690 0.991 Vet = 8.47 25 20.63 1.728 0.0 8.000 14.958 to 120.0 0.0 0.0 0.0 88 82.57 0.1578 0.0 8.000 1.262 VeI = 11.30 88 0.0 1.728 T 8.0 62.420 16.220 to 120.0 2E 8.0 16.000 -0.325 12 82.57 0.1577 0.0 78.420 12.370 Vet = 11.30 0.0 82.57 28.265 KFactor= 15.53 18 21.49 3.314 0.0 9.670 12.388 to 120.0 0.0 0.0 0.0 20 21.49 0.0006 0.0 9.670 0.006 VeI = 0.80 20 21.26 3.314 2E 14.0 11.440 12.394 to 120.0 0.0 14.000 0.901 21 42.75 0.0019 0.0 25.440 0.049 Vet = 1.59 21 -20.22 3.314 0.0 8.880 13.344 to 120.0 0.0 0.0 0.0 22 22.53 0.0007 0.0 8.880 0.006 Vet = 0.84 0.0 22.53 13.350 KFactor= 6.17 7 99.29 3.314 0.0 9.670 24.822 to 120.0 0.0 0.0 0.0 8 99.29 0.0093 0.0 9.670 0.090 Vet = 3.69 8 99.60 3.314 2E 14.0 14.330 24.912 to 120.0 0.0 14.000 0.576 9 198.89 0.0336 0.0 28.330 0.953 Vet = 7.40 9 80.06 3.314 2E 14.0 15.000 26.441 to 120.0 0.0 14.000 0.0 12 278.95 0.0629 0.0 29.000 1.824 Vet = 10.38 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 8 18433 State Mixed Use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 12 82.57 3.314 4E 28.0 60.670 28.265 to 120.0 T 15.0 43.000 0.580 10 361.52 0.1016 0.0 103.670 10.538 Vel = 13.45 10 0.0 3.314 0.0 45.080 39.383 to 120.0 0.0 0.0 -1.156 11 361.52 0.1016 0.0 45.080 4.582 Vel = 13.45 11 0.0 4.31 2E 20.0 45.580 42.809 to 120.0 2T 40.0 60.000 0.758 TR1 361.52 0.0283 0.0 105.580 2.984 Vel = 7.95 TR1 0.0 4.31 E 10.0 8.000 46.551 to 120.0 T 20.0 30.000 3.465 BR1 361.52 0.0283 0.0 38.000 1.074 Vel = 7.95 BRI 0.0 4.31 0.0 6.370 51.090 to 120.0 0.0 0.0 -3.608 S2 361.52 0.0284 0.0 6.370 0.181 Vel = 7.95 S2 0.0 4.31 3E 30.0 20.620 47.663 to 120.0 B 12.0 62.000 0.0 S3 361.52 0.0283 T 20.0 82.620 2.335 Vel = 7.95 S3 0.0 4.31 5E 50.0 53.830 49.998 to 120.0 T 20.0 70.000 0.0 T 361.52 0.0283 0.0 123.830 3.501 Vel = 7.95 T 0.0 4.31 2E 20.0 8.830 53.499 to 120.0 0.0 20.000 5.340 BFI 361.52 0.0283 0.0 28.830 0.815 Vel = 7.95 BF1 0.0 8.27 2E 47.88 10.000 59.654 to 140.0 Zid 0.0 47.880 7.503 * * Fixed Loss = 7.503 BF2 361.52 0.0009 0.0 57.880 0.052 Vel = 2.16 BF2 0.0 7.68 T 52.887 41.000 67.209 to 150.0 G 6.044 86.130 0.0 POC 361.52 0.0011 2F 27.199 127.130 0.142 Vel = 2.50 POC 0.0 9.42 T 75.553 52.000 67.351 to 150.0 0.0 75.553 0.0 UG1 361.52 0.0004 0.0 127.553 0.053 Vel = 1.66 UGI 0.0 11.2 0.0 209.490 67.404 to 150.0 0.0 0.0 -0.866 TEST 361.52 0.0002 0.0 209.490 0.038 Vel = 1.18 250.00 Qa = 250.00 611.52 66.576 K Factor= 74.95 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - . - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 18433 State Mixed Use -FP Design Building : FP-2 Location : LEVEL 1 System : 1 Contract : 18433 Data File 18433 State Mixed Use -FP Design 2PakWXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 18433 State Mixed Use -FP Design Date HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: LEVEL 1 Drawing no: FP-2 Date: 12-6-18 Design Remote area number: 1 Remote area location: PARKING Occupancy classification: OH 2 Density: .15 - Gpm/SqFt Area of application: 1582 - SqFt Coverage per sprinkler: 130 - SqFt Type of sprinklers calculated: QR SSU K5.6 No. of sprinklers calculated: 18 In-rack demand: - GPM Hose streams: 250 - GPM Total water required (including hose streams): 610.68 -GPM @ 62.71 -Psi Type of system: WET Volume of dry or preaction system: -Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 State Mixed Use -FP Design Date City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 5.089 C2 - Residual Pressure: 25.5 D2 - System Flow :360.451 C2 - Residual Flow : 5725 D2 - System Pressure : 64.587 Hose ( Demand) : 250 D3 - System Demand : 610.451 Safety Margin : 11.102 150 140 130 p120 R0 E10° S90 -- S 80 :: R6° E 50 40 30 e2 20 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. 18433 State Mixed Use -FP Design Page 3 Date Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 2V2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA139O'StandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 3500A Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalont longthc shown are standard for actual diameters of Schod 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 State Mixed Use -FP Design Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 18 55.75 12.36 na 17 55.75 12.24 na 2 55.75 5.6 12.13 na 19.5 0.15 130 7.0 3 55.75 5.6 12.13 na 19.5 0.15 130 7.0 4 55.75 5.6 12.21 na 19.57 0.15 130 7.0 5 55.75 5.6 12.56 na 19.84 0.15 130 7.0 6 55.75 5.6 13.39 na 20.49 0.15 130 7.0 87 55.75 5.6 14.61 na 21.4 0.15 130 7.0 20 55.75 12.37 na 34 55.75 12.25 na 28 55.75 5.6 12.14 na 19.51 0.15 130 7.0 29 55.75 5.6 12.14 na 19.51 0.15 130 7.0 30 55.75 5.6 12.22 na 19.58 0.15 130 7.0 31 55.75 5.6 12.58 na 19.86 0.15 130 7.0 32 55.75 5.6 13.41 na 20.51 0.15 130 7.0 89 55.75 5.6 14.65 na 21.43 0.15 130 7.0 38S 55.75 12.52 na 39S 55.75 5.6 12.18 na 19.54 0.15 130 7.0 40S 55.75 5.6 12.57 na 19.85 0.15 130 7.0 gUS 5575 5.6 13.2 na 20.35 0.15 130 7.0 23S 55.75 12.55 na 24S 55.75 5.6 12.24 na 19.59 0.15 130 7.0 25S 55.75 5.6 12.68 na 19.94 0.15 130 7.0 88S 55.75 5.6 13.37 na 20.48 0.15 130 7.0 21 53.67 13.31 na 38 53.67 13.42 na 39 53.67 13.52 na 40 53.67 13.92 na 90 53.67 14.58 na 22 53.67 13.32 na 23 53.67 13.45 na 24 53.67 13.58 na 25 53.67 14.04 na 88 53.67 14.75 na 7 55.75 22.95 na 8 55.75 23.04 na 9 54.42 24.59 na 12 54.42 26.41 na 10 53.08 37.47 na 11 55.75 40.87 na TR1 54.0 44.6 na BR1 46.0 49.13 na S2 54.33 45.71 na S3 54.33 48.03 na T 54.33 51.51 na BFI 42.0 57.66 na BF2 42.0 65.22 na POC 42.0 65.36 na UGI 42.0 65.42 na TEST 44.0 64.59 na 250.0 The maximum velocity is 13.77 and it occurs in the pipe between nodes 89 and 8 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 State Mixed Use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 18 -19.99 1.728 T 8.0 2.450 12.364 to 120.0 0.0 8.000 0.0 17 -19.99 -0.0114 0.0 10.450 -0.119 Vet = 2.73 17 0.0 1.728 T 8.0 2.450 12.245 to 120.0 0.0 8.000 0.0 2 -19.99 -0.0115 0.0 10.450 -0.120 Vet = 2.73 2 19.50 1.728 0.0 10.690 12.125 K Factor =5.60 to 120.0 0.0 0.0 0.0 3 -0.49 0.0 0.0 10.690 0.0 Vet = 0.07 3 19.50 1.728 0.0 8.000 12.125 K Factor= 5.60 to 120.0 0.0 0.0 0.0 4 19.01 0.0105 0.0 8.000 0.084 Vet = 2.60 4 19.57 1.728 0.0 9.000 12.209 K Factor = 5.60 to 120.0 0.0 0.0 0.0 5 38.58 0.0386 0.0 9.000 0.347 Vet = 5.28 5 19.84 1.728 0.0 10.000 12.556 K Factor = 5.60 to 120.0 0.0 0.0 0.0 6 58.42 0.0832 0.0 10.000 0.832 Vet = 7.99 6 20.49 1.728 0.0 8.420 13.388 K Factor =5.60 to 120.0 0.0 0.0 0.0 87 78.91 0.1450 0.0 8.420 1.221 Vet = 10.80 87 21.40 1.728 T 8.0 28.870 14.609 K Factor =5.60 to 120.0 0.0 8.000 0.0 7 100.31 0.2261 0.0 36.870 8.337 Vet = 13.72 0.0 100.31 22.946 K Factor = 20.94 20 -19.73 1.728 T 8.0 2.450 12.369 to 120.0 0.0 8.000 0.0 34 -19.73 -0.0112 0.0 10.450 -0.117 Vet = 2.70 34 0.0 1.728 0.0 10.340 12.252 to 120.0 0.0 0.0 0.0 28 -19.73 -0.0111 0.0 10.340 -0.115 Vet = 2.70 28 19.51 1.728 0.0 10.690 12.137 K Factor =5.60 to 120.0 0.0 0.0 0.0 29 -0.22 0.0 0.0 10.690 0.0 Vet = 0.03 29 19.51 1.728 0.0 8.000 12.137 K Factor =5.60 to 120.0 0.0 0.0 0.0 30 19.29 0.0107 0.0 8.000 0.086 Vet = 2.64 30 19.58 1.728 0.0 9.000 12.223 K Factor =5.60 to 120.0 0.0 0.0 0.0 31 38.87 0.0391 0.0 9.000 0.352 Vet = 5.32 31 19.86 1.728 0.0 10.000 12.575 K Factor =5.60 to 120.0 0.0 0.0 0.0 32 58.73 0.0840 0.0 10.000 0.840 Vet = 8.03 32 20.51 1.728 0.0 8.420 13.415 K Factor =5.60 to 120.0 0.0 0.0 0.0 89 79.24 0.1462 0.0 8.420 1.231 Vet = 10.84 89 21.43 1.728 T 8.0 28.870 14.646 K Factor 5.60 to 120.0 0.0 8.000 0.0 8 100.67 0.2276 0.0 36.870 8.392 Vet = 13.77 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 State Mixed Use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 100.67 23.038 K Factor= 20.97 38S 0.0 1.191 T 5.0 1.580 12.517 to 120.0 0.0 5.000 0.901 38 0.0 0.0 0.0 6.580 0.0 Vel = 0 0.0 0.0 13.418 K Factor = 0 39S 19.54 1.191 T 5.0 1.580 12.178 K Factor =5.60 to 120.0 0.0 5.000 0.901 39 19.54 0.0670 0.0 6.580 0.441 Vel = 5.63 0.0 19.54 13.520 K Factor = 5.31 40S 19.85 1.191 T 5.0 1.580 12.568 K Factor= 5.60 to 120.0 0.0 5.000 0.901 40 19.85 0.0691 0.0 6.580 0.455 Vel = 5.72 0.0 19.85 13.924 K Factor= 5.32 90S 20.35 1.191 T 5.0 1.580 13.202 K Factor =5.60 to 120.0 0.0 5.000 0.901 90 20.35 0.0723 0.0 6.580 0.476 Vel = 5.86 0.0 20.35 14.579 K Factor= 5.33 23S 0.0 1.191 T 5.0 1.580 12.550 to 120.0 0.0 5.000 0.901 23 0.0 0.0 0.0 6.580 0.0 Vel = 0 0.0 0.0 13.451 K Factor = 0 24S 19.59 1.191 T 5.0 1.580 12.238 K Factor= 5.60 to 120.0 0.0 5.000 0.901 24 19.59 0.0673 0.0 6.580 0.443 Vel = 5.64 0.0 19.59 13.582 KFactor= 5.32 25S 19.94 1.191 T 5.0 1.580 12.680 K Factor =5.60 to 120.0 0.0 5.000 0.901 25 19.94 0.0696 0.0 6.580 0.458 Vel = 5.74 0.0 19.94 14.039 K Factor= 5.32 88S 20.48 1.191 T 5.0 1.580 13.370 K Factor =5.60 to 120.0 0.0 5.000 0.901 88 20.48 0.0733 0.0 6.580 0.482 Vel = 5.90 0.0 - 20.48 14.753 K Factor= 5.33 21 18.55 1.728 T 8.0 2.450 13.314 to 120.0 0.0 8.000 0.0 38 18.55 0.0100 0.0 10.450 0.104 Vel = 2.54 38 0.0 1.728 0.0 10.340 13.418 to 120.0 0.0 0.0 0.0 39 18.55 0.0099 0.0 10.340 0.102 Vel = 2.54 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 18433 State Mixed Use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 39 19.54 1.728 0.0 10.690 13.520 to 120.0 0.0 0.0 0.0 40 38.09 0.0378 0.0 10.690 0.404 Vel = 5.21 40 19.86 1.728 0.0 8.000 13.924 to 120.0 0.0 0.0 0.0 90 57.95 0.0819 0.0 8.000 0.655 Vel = 7.93 90 20.34 1.728 T 8.0 56.270 14.579 to 120.0 2E 8.0 16.000 -0.325 9 78.29 0.1430 0.0 72.270 10.332 Vel = 10.71 0.0 78.29 24.586 K Factor= 15.79 22 21.17 1.728 T 8.0 2.450 13.318 to 120.0 0.0 8.000 0.0 23 21.17 0.0127 0.0 10.450 0.133 Vel = 2.90 23 0.0 1.728 0.0 10.340 13.451 to 120.0 0.0 0.0 0.0 24 21.17 0.0127 0.0 10.340 0.131 Vel = 2.90 24 19.59 1.728 0.0 10.690 13.582 to 120.0 0.0 0.0 0.0 25 40.76 0.0428 0.0 10.690 0.457 Vel = 5.58 25 19.94 1.728 0.0 8.000 14.039 to 120.0 0.0 0.0 0.0 88 60.7 0.0892 0.0 8.000 0.714 Vel = 8.30 88 20.47 1.728 1 8.0 62.420 14.753 to 120.0 2E 8.0 16.000 -0.325 12 81.17 0.1528 0.0 78.420 11.986 VeI= 11.10 0.0 81.17 26.414 KFactor= 15.79 18 19.99 3.314 0.0 9.670 12.364 to 120.0 0.0 0.0 0.0 20 19.99 0.0005 0.0 9.670 0.005 Vel = 0.74 20 19.73 3.314 2E 14.0 11.440 12.369 to 120.0 0.0 14.000 0.901 21 39.72 0.0017 0.0 25.440 0.044 Vel = 1.48 21 -18.55 3.314 0.0 8.880 13.314 to 120.0 0.0 0.0 0.0 22 21.17 0.0005 0.0 8.880 0.004 Vel = 0.79 0.0 21.17 13.318 K Factor = 5.80 7 100.31 3.314 0.0 9.670 22.946 to 120.0 0.0 0.0 0.0 8 100.31 0.0095 0.0 9.670 0.092 Vel = 3.73 8 100.67 3.314 2E 14.0 14.330 23.038 to 120.0 0.0 14.000 0.576 9 200.98 0.0343 0.0 28.330 0.972 Vel = 7.48 9 78.30 3.314 2E 14.0 15.000 24.586 to 120.0 0.0 14.000 0.0 12 279.28 0.0630 0.0 29.000 1.828 Vel = 10.39 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 8 18433 State Mixed Use -FP Design Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 1'C'.or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 12 81.17 3.314 4E 28.0 60.670 26.414 to 120.0 T 15.0 43.000 0.580 10 360.45 0.1011 0.0 103.670 10.480 Vel = 13.41 10 0.0 3.314 0.0 45.080 37.474 to 120.0 0.0 0.0 -1.156 11 360.45 0.1011 0.0 45.080 4.557 Vet = 13.41 11 0.0 4.31 2E 20.0 45.580 40.875 to 120.0 2T 40.0 60.000 0.758 TR1 360.45 0.0281 0.0 105.580 2.968 Vel = 7.93 TRI 0.0 4.31 E 10.0 8.000 44.601 to 120.0 T 20.0 30.000 3.465 BR1 360.45 0.0281 0.0 38.000 1.068 Vel = 7.93 BRI 0.0 4.31 0.0 6.370 49.134 to 120.0 0.0 0.0 -3.608 S2 360.45 0.0283 0.0 6.370 0.180 Vel = 7.93 S2 0.0 4.31 3E 30.0 20.620 45.706 to 120.0 B 12.0 62.000 0.0 S3 360.45 0.0281 T 20.0 82.620 2.322 Vel = 7.93 S3 0.0 4.31 5E 50.0 53.830 48.028 to 120.0 T 20.0 70.000 0.0 T 360.45 0.0281 0.0 123.830 3.482 Vet = 7.93 T 0.0 4.31 2E 20.0 8.830 51.510 to 120.0 0.0 20.000 5.340 BFI 360.45 0.0281 0.0 28.830 0.810 Vet = 7.93 BF1 0.0 8.27 2E 47.88 10.000 57.660 to 140.0 Zid 0.0 47.880 7.510 * * Fixed Loss = 7.51 BF2 360.45 0.0009 0.0 57.880 0.052 Vet = 2.15 BF2 0.0 7.68 T 52.887 41.000 65.222 to 150.0 G 6.044 86.130 0.0 POC 360.45 0.0011 2F 27.199 127.130 0.142 Vet = 2.50 POC 0.0 9.42 T 75.553 52.000 65.364 to 150.0 0.0 75.553 0.0 UG1 360.45 0.0004 0.0 127.553 0.052 Vel = 1.66 UGI 0.0 11.2 0.0 209.490 65.416 to 150.0 0.0 0.0 -0.866 TEST 360.45 0.0002 0.0 209.490 0.037 Vel = 1.17 250.00 Qa = 250.00 610.45 64.587 K Factor= 75.96 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Ak F.W. ~~il. ~Eq - - - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 18433 STATE OF MIXED USE Building : FP-3 Location : LEVEL 4 System : 3 Contract 18433 Data File : 18433 State Mixed Use -FP Design 3) L4 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 1 18433 STATE OF MIXED USE Date 9-11-18 HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: LEVEL 4 Drawing no: FP-3 Date: 9-12-18 Design Remote area number: 3 Remote area location: RESIDENTIAL Occupancy classification: LH Density: .05 - Gpm/SqFt Area of application: 1600 - SqFt Coverage per sprinkler: 400 - SqFt Type of sprinklers calculated: RESID. PENDENT 4.9 No. of sprinklers calculated: 4 In-rack demand: N/A - GPM Hose streams: 100 -GPM Total water required (including hose streams): 189.1 -GPM @ 69.86 -Psi Type of system: WET Volume of dry or preaction system: - Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 STATE OF MIXED USE Date 9-11-18 City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 18.589 C2 - Residual Pressure: 25.5 02 - System Flow : 89.109 C2 - Residual Flow : 5725 D2 - System Pressure : 69.860 Hose ( Demand) :100 03 - System Demand :189.109 Safety Margin : 6.547 150 140 130 p120 R110 E10° 90 80 -C4-- U7° - R 60 DS - E 50 40 -- 30 -- _ : :i___ [t I I I I . 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. 18433 STATE OF MIXED USE Page Date 3 9-11-18 Fitting Legend Abbrev. Name 1/2 % 1 1% 11/2 2 21,4 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 T NFPA 139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 3500A Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diamotors of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 STATE OF MIXED USE Date 9-11-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. P1 86.92 4.9 16.7 na 20.02 0.05 400 16.7 P2 86.92 4.9 19.27 na 21.51 0.05 400 16.7 P3 86.92 4.9 20.99 na 22.45 0.05 400 16.7 P4 86.92 4.9 26.29 na 25.13 0.05 400 16.7 T2 87.42 20.5 na 13 87.42 21.88 na M2 87.42 28.46 na M3 87.42 28.47 na M4 87.42 35.37 na TR4 87.42 40.79 na BR4 77.17 46.41 na S2 54.33 56.43 na S3 54.33 56.6 na T 54.33 56.87 na BF1 42.0 62.27 na BF2 42.0 70.71 na POC 42.0 70.72 na UG1 42.0 70.72 na TEST 44.0 69.86 na 100.0 The maximum velocity is 21.56 and it occurs in the pipe between nodes T3 and M3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 110.or Ftng's Pe Pv Notes Point Qt Pt/Ft Eqv. Ln. Total Pf Pn P1 20.02 1.101 3N 21.0 16.750 16.700 K Factor =4.90 to 150.0 0.0 21.000 0.0 P2 20.02 0.0682 0.0 37.750, 2.574 Vet = 6.75 P2 21.52 1.101 0 5.0 0.500 19.274 K Factor =4.90 to 150.0 0.0 5.000 -0.217 T2 41.54 0.2631 0.0 5.500 1.447 Vet = 14.00 0.0 41.54 20.504 KFactor= 9.17 P3 22.45 1.101 0 5.0 1.250 20.985 K Factor =4.90 to 150.0 N 7.0 12.000 -0.217 T3 22.45 0.0843 0.0 13.250 1.117 Vet = 7.57 0.0 22.45 21.885 K Factor = 4.80 P4 25.13 1.101 N 7.0 10.950 26.294 K Factor= 4.90 to 150.0 0 5.0 12.000 -0.217 M2 25.13 0.1038 0.0 22.950 2.383 VeI = 8.47 0.0 25.13 28.460 K Factor = 4.71 T2 41.54 1.101 0.0 5.250 20.504 to 150.0 0.0 0.0 0.0 T3 41.54 0.2630 0.0 5.250 1.381 VeI = 14.00 T3 22.44 1.101 0 5.0 6.250 21.885 to 150.0 0.0 5.000 0.0 M3 63.98 0.5849 0.0 11.250 6.580 VeI = 21.56 0.0 63.98 28.465 K Factor 11.99 M2 25.13 2.003 0.0 1.000 28.460 to 150.0 0.0 0.0 0.0 M3 25.13 0.0050 0.0 1.000 0.005 Vel = 2.56 M3 63.98 2.003 0 10.0 86.000 28.465 to 150.0 2N 22.0 32.000 0.0 M4 89.11 0.0586 0.0 118.000 6.909 Vet = 9.07 M4 0.0 2.003 4N 44.0 48.500 35.374 to 150.0 0.0 44.000 0.0 TR4 89.11 0.0586 0.0 92.500 5.416 Vet = 9.07 TR4 0.0 2.203 E 5.0 10.250 40.790 to 120.0 B 6.0 11.000 4.439 BR4 89.11 0.0557 0.0 21.250 1.183 Vet = 7.50 BR4 0.0 4.31 T 20.0 29.000 46.412 to 120.0 E 10.0 30.000 9.892 S2 89.11 0.0021 0.0 59.000 0.126 Vet = 1.96 S2 0.0 4.31 3E 30.0 20.620 56.430 to 120.0 B 12.0 62.000 0.0 S3 89.11 0.0021 T 20.0 82.620 0.174 Vet = 1.96 S3 0.0 4.31 5E 50.0 53.830 56.604 to 120.0 T 20.0 70.000 0.0 T 89.11 0.0021 0.0 123.830 0.263 Vet = 1.96 T 0.0 4.31 2E 20.0 8.830 56.867 to 120.0 0.0 20.000 5.340 BF1 89.11 0.0021 0.0 28.830 0.061 Vet = 1.96 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 -inal Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .1c'.or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BF1 0.0 8.27 2E 47.88 10.000 62.268 to 140.0 Zid 0.0 47.880 8.437 * * Fixed Loss = 8.437 BF2 89.11 0.0001 0.0 57.880 0.004 Vel = 0.53 BF2 0.0 7.68 T 52.887 41.000 70.709 to 150.0 G 6.044 86.130 0.0 POC 89.11 0.0001 2F 27.199 127.130 0.010 Vel = 0.62 POC 0.0 9.42 T 75.553 52.000 70.719 to 150.0 0.0 75.553 0.0 UG1 89.11 0.0 0.0 127.553 0.004 Vel = 0.41 UG1 0.0 11.2 0.0 209.490 70.723 to 150.0 0.0 0.0 -0.866 TEST 89.11 0.0 0.0 209.490 0.003 Vel = 0.29 100.00 Qa= 100.00 189.11 69.860 KFactor 22.63 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 ... Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 18433 STATE OF MIXED USE Building : FP-3 Location : LEVEL 4 System : 4 Contract : 18433 Data File : 18433 State Mixed Use -FP Design ê4L4_STORAGE.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 1 18433 STATE OF MIXED USE Date 9-11-18 HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: LEVEL 4 Drawing no: FP-3 Date: 9-12-18 Design Remote area number: 4 Remote area location: RESIDENTIAL STORAGE Occupancy classification: LH Density: .05 - Gpm/SqFt Area of application: ENTIRE AREA - SqFt Coverage per sprinkler: 400 - SqFt Type of sprinklers calculated: SSP QR 5.6 No. of sprinklers calculated: 8 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 223.27 - GPM Type of system: WET Volume of dry or preaction system: - Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) @ 62.56 -Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 STATE OF MIXED USE Date 9-11-18 City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 18.589 C2 - Residual Pressure: 25.5 D2 - System Flow :123.275 C2 - Residual Flow : 5725 D2 - System Pressure : 62.564 Hose (Demand ) :100 D3 - System Demand : 223.275 Safety Margin : 13.810 150 140 130 p120 R11° E10° s 90 580 : u 70 R 60 D3 E 50 40 - 30 - _ : :i_______________ N N I I I . 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. 18433 STATE OF MIXED USE Page Date 3 9-11-18 Fitting Legend Abbrev. Name 1/ % 1 11/4 11/2 2 21/2 3 31/ 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139O'StandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 C NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplingTee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 T NFPA 1390 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 STATE OF MIXED USE Date 9-11-18 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. P5 86.92 5.6 7.5 na 15.34 0.15 100 7.0 P6 86.92 5.6 7.53 na 15.37 0.15 100 7.0 P7 86.92 5.6 7.65 na 15.49 0.15 100 7.0 P8 86.92 5.6 7.89 na 15.73 0.15 100 7.0 P9 86.92 5.6 7.17 na 15.0 0.15 100 7.0 P10 86.92 5.6 7.58 na 15.42 0.15 100 7.0 P11 86.92 5.6 7.5 na 15.34 0.15 100 7.0 P12 86.92 5.6 7.75 na 15.59 0.15 100 7.0 110 87.42 7.7 na 111 87.42 7.83 na T12 87.42 8.09 na 11 87.42 9.53 na T3 87.42 9.64 na Ml 87.42 8.46 na M2 87.42 9.53 na M3 87.42 9.64 na M4 87.42 22.23 na TR4 87.42 32.11 na BR4 77.17 38.7 na S2 54.33 48.82 na S3 54.33 49.14 na 1 54.33 49.62 na BF1 42.0 55.07 na BF2 42.0 63.4 na POC 42.0 63.42 na UG1 42.0 63.42 na TEST 44.0 62.56 na 100.0 T5 74.33 13.5 na T6 74.33 13.53 na T7 74.33 13.66 na 18 74.33 13.91 na n The maximum velocity is 12.55 and it occurs in the pipe between nodes Ml and M2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn P5 15.34 1.101 N 7.0 1.000 7.504 K Factor= 5.60 to 150.0 0 5.0 12.000 5.453 T5 15.34 0.0416 0.0 13.000 0.541 Vel = 5.17 0.0 15.34 13.498 K Factor= 4.18 P6 15.37 1.101 N 7.0 1.000 7.532 K Factor= 5.60 to 150.0 0 5.0 12.000 5.453 T6 15.37 0.0418 0.0 13.000 0.544 Vel = 5.18 0.0 15.37 13.529 KFactor= 4.18 P7 15.49 1.101 N 7.0 1.000 7.652 K Factor =5.60 to 150.0 0 5.0 12.000 5.453 17 15.49 0.0424 0.0 13.000 0.551 Vel = 5.22 0.0 15.49 13.656 KFactor= 4.19 P8 15.73 1.101 N 7.0 1.000 7.888 K Factor = 5.60 to 150.0 0 5.0 12.000 5.453 T8 15.73 0.0436 0.0 13.000 0.567 Vel = 5.30 0.0 15.73 13.908 K Factor= 4.22 P9 15.00 1.101 N 7.0 6.500 7.175 K Factor =5.60 to 150.0 0 5.0 12.000 -0.217 TIO 15.0 0.0399 0.0 18.500 0.739 Vel = 5.05 0.0 15.00 7.697 K Factor= 5.41 P10 15.42 1.101 N 7.0 1.000 7.578 K Factor =5.60 to 150.0 0.0 7.000 -0.217 T10 15.42 0.0420 0.0 8.000 0.336 Vel = 5.20 0.0 15.42 7.697 K Factor= 5.56 P11 15.34 1.101 N 7.0 1.000 7.503 K Factor= 5.60 to 150.0 0 5.0 12.000 -0.217 Til 15.34 0.0417 0.0 13.000 0.542 Vel = 5.17 0.0 15.34 7.828 ,K Factor= 5.48 P12 15.59 1.101 N 7.0 1.000 7.752 K Factor =5.60 to 150.0 0 5.0 12.000 -0.217 T12 15.59 0.0429 0.0 13.000 0.558 Vel = 5.25 0.0 15.59 8.093 K Factor 5.48 110 30.42 1.598 0.0 5.420 7.697 to 150.0 0.0 0.0 0.0 TII 30.42 0.0242 0.0 5.420 0.131 Vel = 4.87 T11 15.33 1.598 0.0 5.170 7.828 to 150.0 0.0 0.0 0.0 112 45.75 0.0513 0.0 5.170 0.265 Vel = 7.32 T12 15.60 1.598 R 1.0 3.170 8.093 to 150.0 0.0 1.000 0.0 Ml 61.35 0.0882 0.0 4.170 0.368 Vel = 9.81 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 11G,or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 61.35 8.461 KFactor= 21.09 TI 0.0 1.101 0 5.0 4.790 9.532 to 150.0 0.0 5.000 0.0 M2 0.0 0.0 0.0 9.790 0.0 Vel = 0 0.0 0.0 9.532 K Factor = 0 13 0.0 1.101 0 5.0 6.250 9.639 to 150.0 0.0 5.000 0.0 M3 0.0 0.0 0.0 11.250 0.0 Vel = 0 0.0 0.0 9.639 K Factor = 0 Ml 123.28 2.003 0.0 10.040 8.461 to 150.0 0.0 0.0 0.0 M2 123.28 0.1067 0.0 10.040 1.071 Vel = 12.55 M2 0.0 2.003 0.0 1.000 9.532 to 150.0 0.0 0.0 0.0 M3 123.28 0.1070 0.0 1.000 0.107 Vel = 12.55 M3 0.0 2.003 0 10.0 86.000 9.639 to 150.0 2N 22.0 32.000 0.0 M4 123.28 0.1067 0.0 118.000 12.595 Vel = 12.55 M4 0.0 2.003 4N 44.0 48.500 22.234 to 150.0 0.0 44.000 0.0 TR4 123.28 0.1067 0.0 92.500 9.872 Vel = 12.55 TR4 0.0 2.203 E 5.0 10.250 32.106 to 120.0 B 6.0 11.000 4.439 BR4 123.28 0.1015 0.0 21.250 2.157 Vel = 10.38 BR4 0.0 4.31 T 20.0 29.000 38.702 to 120.0 E 10.0 30.000 9.892 S2 123.28 0.0039 0.0 59.000 0.228 Vel = 2.71 S2 0.0 4.31 3E 30.0 20.620 48.822 to 120.0 B 12.0 62.000 0.0 S3 123.28 0.0039 1 20.0 82.620 0.319 Vel = 2.71 S3 0.0 4.31 5E 50.0 53.830 49.141 to 120.0 T 20.0 70.000 0.0 T 123.28 0.0039 0.0 123.830 0.478 Vel = 2.71 T 0.0 4.31 2E 20.0 8.830 49.619 to 120.0 0.0 20.000 5.340 BF1 123.28 0.0039 0.0 28.830 0.112 Vel = 2.71 BFI 0.0 8.27 2E 47.88 10.000 55.071 to 140.0 Zid 0.0 47.880 8.321 * * Fixed Loss 8.321 BF2 123.28 0.0001 0.0 57.880 0.006 Vel = 0.74 BF2 0.0 7.68 T 52.887 41.000 63.398 to 150.0 G 6.044 86.130 0.0 POC 123.28 0.0002 2F 27.199 127.130 0.020 Vel = 0.85 POC 0.0 9.42 T 75.553 52.000 63.418 to 150.0 0.0 75.553 0.0 UG1 123.28 0.0001 0.0 127.553 0.007 Vel = 0.57 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn UG1 0.0 11.2 0.0 209.490 63.425 to 150.0 0.0 0.0 -0.866 TEST 123.28 0.0 0.0 209.490 0.005 Vel = 0.40 100.00 Qa= 100.00 223.28 62.564 K Factor = 28.23 T5 15.34 1.598 0.0 4.500 13.498 to 150.0 0.0 0.0 0.0 T6 15.34 0.0069 0.0 4.500 0.031 Vel = 2.45 T6 15.37 1.598 0.0 5.210 13.529 to 150.0 0.0 0.0 0.0 T7 30.71 0.0244 0.0 5.210 0.127 Vel = 4.91 T7 15.49 1.598 0.0 4.830 13.656 to 150.0 0.0 0.0 0.0 T8 46.2 0.0522 0.0 4.830 0.252 Vel = 7.39 T8 15.73 1.598 R 1.0 1.470 13.908 to 150.0 0.0 1.000 -5.669 Ml 61.93 0.0899 0.0 2.470 0.222 Vel = 9.91 0.0 61.93 8.461 K Factor= 21.29 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 18433 STATE OF MIXED USE Building : FP-3 Location : LEVEL 3 System : 5 Contract : 18433 Data File : 18433 State Mixed Use -FP Desgn(AJa5-L3_RES.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 1 18433 STATE OF MIXED USE Date 9-11-18 HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: LEVEL 3 Drawing no: FP-3 Date: 9-12-18 Design Remote area number: 5 Remote area location: RESIDENTIAL Occupancy classification: LH Density: .05 - Gpm/SqFt Area of application: 1600 - SqFt Coverage per sprinkler: 400 - SqFt Type of sprinklers calculated: RESI D. PENDENT 4.9 No. of sprinklers calculated: 4 In-rack demand: N/A - GPM Hose streams: 100 -GPM Total water required (including hose streams): 180.35 - GPM @ 48.31 -Psi Type of system: WET Volume of dry or preaction system: - Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 STATE OF MIXED USE Date 9-11-18 City Water Supply: Demand: Cl - Static Pressure : 76.5 01 - Elevation : 12.919 C2 - Residual Pressure: 25.5 D2 - System Flow : 80.359 C2 - Residual Flow : 5725 02 - System Pressure : 48.317 Hose ( Demand) :100 D3 - System Demand :180.359 Safety Margin : 28.098 150 140 130 p120 R11° E10° C11 s 9° S 80 U 70 R 60 E 50 D2 ________ 40 D3 20 10 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (NA 1.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. 18433 STATE OF MIXED USE Page Date 3 9-11-18 Fitting Legend Abbrev. Name 1/ % 1 11/4 11/2 2 21/2 3 31/ 4 5 6 8 10 12 14 16 18 20 24 B NFPA13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with '. The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 STATE OF MIXED USE Date 9-11-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. P1 73.83 4.9 16.78 na 20.07 0.05 400 16.7 P4 73.83 4.9 17.02 na 20.22 0.05 400 16.7 P3 73.83 4.9 16.7 na 20.02 0.05 400 16.7 P2 73.83 4.9 16.73 na 20.04 0.05 400 16.7 Ti 74.33 17.72 na T3 74.33 17.39 na Ml 74.33 20.21 na M2 74.33 20.16 na M3 74.33 20.15 na M8 74.33 22.6 na M7 74.33 23.27 na M6 74.33 24.56 na TR3 74.33 25.2 na BR3 64.08 30.62 na S2 54.33 34.95 na S3 54.33 35.09 na T 54.33 35.31 na BF1 42.0 40.7 na BF2 42.0 49.17 na POC 42.0 49.18 na UG1 42.0 49.18 na TEST 44.0 48.32 na 100.0 M4 74.33 20.87 na T5 74.33 20.29 na T6 74.33 20.26 na T7 74.33 20.24 na T8 74.33 20.22 na M5 74.33 21.62 na The maximum velocity is 13.58 and it occurs in the pipe between nodes TI and M3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn P1 20.07 1.101 N 7.0 4.830 16.784 K Factor= 4.90 to 150.0 0 5.0 12.000 -0.217 Ti 20.07 0.0685 0.0 16.830 1.153 Vel = 6.76 0.0 20.07 17.720 K Factor= 4.77 P4 20.22 1.101 N 7.0 6.170 17.023 K Factor= 4.90 to 150.0 0.0 7.000 -0.217 Ti 20.22 0.0694 0.0 13.170 0.914 Vel = 6.81 0.0 20.22 17.720 K Factor = 4.80 P3 20.02 1.101 N 7.0 1.250 16.700 K Factor 4.90 to 150.0 0 5.0 12.000 -0.217 T3 20.02 0.0682 0.0 13.250 0.904 Vel = 6.75 0.0 20.02 17.387 K Factor= 4.80 P2 20.04 1.101 N 7.0 5.750 16.732 K Factor =4.90 to 150.0 0.0 7.000 -0.217 13 20.04 0.0684 0.0 12.750 0.872 Vel = 6.75 0.0 20.04 17.387 K Factor= 4.81 TI 40.29 1.101 0 5.0 4.790 17.720 to 150.0 0.0 5.000 0.0 M3 40.29 0.2486 0.0 9.790 2.434 Vel = 13.58 0.0 40.29 20.154 K Factor= 8.97 13 40.07 1.101 0 5.0 6.250 17.387 to 150.0 0.0 5.000 0.0 M2 40.07 0.2460 0.0 11.250 2.768 Vel = 13.50 0.0 40.07 20.155 KFactor= 8.93 Ml -12.52 1.598 0.0 11.000 20.206 to 150.0 0.0 0.0 0.0 M2 -12.52 -0.0046 0.0 11.000 -0.051 Vel = 2.00 M2 4.87 1.598 0.0 0.420 20.155 to 150.0 0.0 0.0 0.0 M3 -7.65 -0.0024 0.0 0.420 -0.001 Vel = 1.22 M3 40.29 1.598 0 8.0 63.250 20.154 to 150.0 2N 18.0 26.000 0.0 M8 32.64 0.0274 0.0 89.250 2.449 Vel = 5.22 M8 0.0 1.598 0.0 24.340 22.603 to 150.0 0.0 0.0 0.0 M7 32.64 0.0274 0.0 24.340 0.668 Vel = 5.22 M7 11.55 2.003 3N 33.0 47.540 23.271 to 150.0 0.0 33.000 0.0 M6 44.19 0.0160 0.0 80.540 1.288 Vel = 4.50 M6 36.17 2.003 N 11.0 2.330 24.559 to 150.0 0.0 11.000 0.0 TR3 80.36 0.0484 0.0 13.330 0.645 Vel = 8.18 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn TR3 0.0 2.203 E 5.0 10.250 25.204 to 120.0 B 6.0 11.000 4.439 BR3 80.36 0.0460 0.0 21.250 0.977 Vet = 6.76 BR3 0.0 4.31 T 20.0 29.000 30.620 to 120.0 E 10.0 30.000 4.223 S2 80.36 0.0017 0.0 59.000 0.103 Vet = 1.77 S2 0.0 4.31 3E 30.0 20.620 34.946 to 120.0 B 12.0 62.000 0.0 S3 80.36 0.0018 T 20.0 82.620 0.145 Vet = 1.77 S3 0.0 4.31 SE 50.0 53.830 35.091 to 120.0 T 20.0 70.000 0.0 T 80.36 0.0017 0.0 123.830 0.216 Vet = 1.77 1 0.0 4.31 2E 20.0 8.830 35.307 to 120.0 0.0 20.000 5.340 BF1 80.36 0.0018 0.0 28.830 0.051 Vet = 1.77 BF1 0.0 8.27 2E 47.88 10.000 40.698 to 140.0 Zid 0.0 47.880 8.468 * * Fixed Loss = 8.468 BF2 80.36 0.0001 0.0 57.880 0.003 Vet = 0.48 BF2 0.0 7.68 T 52.887 41.000 49.169 to 150.0 G 6.044 86.130 0.0 POC 80.36 0.0001 2F 27.199 127.130 0.009 Vet = 0.56 POC 0.0 9.42 T 75.553 52.000 49.178 to 150.0 0.0 75.553 0.0 UGI 80.36 0.0 0.0 127.553 0.003 Vet = 0.37 UG1 0.0 11.2 0.0 209.490 49.181 to 150.0 0.0 0.0 -0.866 TEST 80.36 0.0 0.0 209.490 0.002 Vet = 0.26 100.00 Qa= 100.00 180.36 48.317 K Factor= 25.95 M2 35.21 1.598 0 8.0 14.620 20.155 to 150.0 0.0 8.000 0.0 M4 35.21 0.0316 0.0 22.620 0.714 Vet = 5.63 M4 -23.66 1.101 2R 2.0 90.500 20.869 to 150.0 0 5.0 7.000 0.0 M7 11.55 0.0246 0.0 97.500 2.402 Vet = 3.89 0.0 11.55 23.271 K Factor= 2.39 T5 -12.52 1.598 0.0 4.500 20.286 to 150.0 0.0 0.0 0.0 16 -12.52 -0.0047 0.0 4.500 -0.021 Vet = 2.00 16 0.0 1.598 0.0 5.210 20.265 to 150.0 0.0 0.0 0.0 T7 -12.52 -0.0048 0.0 5.210 -0.025 Vet = 2.00 17 0.0 1.598 0.0 4.830 20.240 to 150.0 0.0 0.0 0.0 T8 -12.52 -0.0046 0.0 4.830 -0.022 Vet = 2.00 18 0.0 1.598 R 1.0 1.470 20.218 to 150.0 0.0 1.000 0.0 Ml -12.52 -0.0049 0.0 2.470 -0.012 Vet = 2.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 -12.52 20.206 K Factor -2.79 T5 12.52 1.598 3N 27.0 97.250 20.286 to 150.0 R 1.0 28.000 0.0 M4 12.52 0.0047 0.0 125.250 0.583 Vel = 2.00 M4 23.65 1.598 0 8.0 14.620 20.869 to 150.0 0.0 8.000 0.0 M5 36.17 0.0332 0.0 22.620 0.751 Vel = 5.79 M5 0.0 1.598 0 8.0 71.580 21.620 to 150.0 N 9.0 17.000 0.0 M6 36.17 0.0332 0.0 88.580 2.939 Vel = 5.79 0.0 36.17 24.559 K Factor= 7.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : 18433 STATE OF MIXED USE Building : FP-3 Location : LEVEL 3 System : 6 Contract : 18433 Data File : 18433 State Mixed Use -FP Design L3_STORAGE.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 1 18433 STATE OF MIXED USE Date 9-11-18 HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: LEVEL 3 Drawing no: FP-3 Date: 9-12-18 Design Remote area number: 6 Remote area location: RESIDENTIAL STORAGE Occupancy classification: OH 1 Density: .15 - Gpm/SqFt Area of application: ENTIRE AREA - SqFt Coverage per sprinkler: 100 - SqFt Type of sprinklers calculated: SSP QR 5.6 No. of sprinklers calculated: 8 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 374.77 - GPM Type of system: WET Volume of dry or preaction system: - Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) @ 46.47 - Psi Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 STATE OF MIXED USE Date 9-11-18 City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 12.919 C2 - Residual Pressure: 25.5 D2 - System Flow :124.775 C2 - Residual Flow : 5725 D2 - System Pressure : 46.474 Hose ( Demand) : 250 D3 - System Demand : 374.775 Safety Margin : 29.697 150 140 130 p120 R 11 F10° s 90 S 80 U 70 R 60 .D2- E 50 40 D2. 30 e2 _ : :: I . 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 3 18433 STATE OF MIXED USE Date 9-11-18 Fitting Legend Abbrev. Name 1/2 3/4 1 1% 11/2 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA I345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 R * CPVC Coupling Tee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 STATE OF MIXED USE Date 9-11-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. P5 73.83 5.6 8.03 na 15.87 0.15 100 7.0 P6 73.83 5.6 8.0 na 15.84 0.15 100 7.0 P7 73.83 5.6 8.0 na 15.84 0.15 100 7.0 P8 73.83 5.6 8.04 na 15.87 0.15 100 7.0 P9 73.83 5.6 7.17 na 15.0 0.15 100 7.0 P10 73.83 5.6 7.58 na 15.42 0.15 100 7.0 P11 73.83 5.6 7.5 na 15.34 0.15 100 7.0 P12 73.83 5.6 7.75 na 15.59 0.15 100 7.0 110 74.33 7.7 na 111 74.33 7.83 na T12 74.33 8.09 na TI 74.33 10.56 na 13 74.33 10.59 na Ml 74.33 8.46 na M2 74.33 10.56 na M3 74.33 10.59 na M8 74.33 15.87 na M7 74.33 17.31 na M6 74.33 20.16 na 1R3 74.33 21.62 na BR3 64.08 28.26 na S2 54.33 32.72 na S3 54.33 33.04 na 1 54.33 33.53 na BF1 42.0 38.99 na BF2 42.0 47.31 na POC 42.0 47.33 na UG1 42.0 47.34 na TEST 44.0 46.47 na 250.0 M4 74.33 11.63 na T5 74.33 8.39 na T6 74.33 8.36 na 17 74.33 8.36 na T8 74.33 8.4 na M5 74.33 13.36 na The maximum velocity is 14.91 and it occurs in the pipe between nodes Ml and M2 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn P5 15.87 1.101 N 7.0 1.000 8.033 K Factor =5.60 to 150.0 0 5.0 12.000 -0.217 15 15.87 0.0444 0.0 13.000 0.577 Vet = 5.35 0.0 15.87 8.393 K Factor= 5.48 P6 15.84 1.101 N 7.0 1.000 8.003 K Factor =5.60 to 150.0 0 5.0 12.000 -0.217 16 15.84 0.0442 0.0 13.000 0.575 Vet = 5.34 0.0 15.84 8.361 K Factor= 5.48 P7 15.84 1.101 N 7.0 1.000 8.003 K Factor= 5.60 to 150.0 0 5.0 12.000 -0.217 T7 15.84 0.0442 0.0 13.000 0.575 Vet = 5.34 0.0 15.84 8.361 K Factor = 5.48 P8 15.87 1.101 N 7.0 1.900 8.036 K Factor =5.60 to 150.0 0 5.0 12.000 -0.217 18 15.87 0.0444 0.0 13.000 0.577 Vet = 5.35 0.0 15.87 8.396 K Factor= 5.48 P9 15.00 1.101 N 7.0 6.500 7.175 K Factor = 5.60 to 150.0 0 5.0 12.000 -0.217 TIO 15.0 0.0399 0.0 18.500 0.739 Vet = 5.05 0.0 15.00 7.697 K Factor = 5.41 P10 15.42 1.101 N 7.0 1.000 7.578 K Factor =5.60 to 150.0 0.0 7.000 -0.217 110 15.42 0.0420 0.0 8.000 0.336 Vet = 5.20 0.0 15.42 7.697 K Factor= 5.56 P11 15.34 1.101 N 7.0 1.000 7.503 K Factor = 5.60 to 150.0 0 5.0 12.000 -0.217 Til 15.34 0.0417 0.0 13.000 0.542 Vet = 5.17 0.0 15.34 7.828 KFactor= 5.48 P12 15.59 1.101 N 7.0 1.000 7.752 K Factor= 5.60 to 150.0 0 5.0 12.000 -0.217 T12 15.59 0.0429 0.0 13.000 0.558 Vet = 5.25 0.0 15.59 8.093 K Factor= 5.48 110 30.42 1.598 0.0 5.420 7.697 to 150.0 0.0 0.0 0.0 111 30.42 0.0242 0.0 5.420 0.131 Vet = 4.87 T11 15.33 1.598 0.0 5.170 7.828 to 150.0 0.0 0.0 0.0 T12 45.75 0.0513 0.0 5.170 0.265 Vet = 7.32 112 15.60 1.598 R 1.0 3.170 8.093 to 150.0 0.0 1.000 0.0 Ml 61.35 0.0882 0.0 4.170 0.368 Vet = 9.81 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 61.35 8.461 K Factor= 21.09 TI 0.0 1.101 0 5.0 4.790 10.563 to 150.0 0.0 5.000 0.0 M2 0.0 0.0 0.0 9.790 0.0 Vel = 0 0.0 0.0 10.563 K Factor = 0 13 0.0 1.101 0 5.0 6.250 10.588 to 150.0 0.0 5.000 0.0 M3 0.0 0.0 0.0 11.250 0.0 Vel = 0 0.0 0.0 10.588 K Factor = 0 Ml 93.18 1.598 0.0 11.000 8.461 to 150.0 0.0 0.0 0.0 M2 93.18 0.1911 0.0 11.000 2.102 Vel = 14.91 M2 -43.71 1.598 0.0 0.420 10.563 to 150.0 0.0 0.0 0.0 M3 49.47 0.0595 0.0 0.420 0.025 Vel = 7.91 M3 0.0 1.598 0 8.0 63.250 10.588 to 150.0 2N 18.0 26.000 0.0 M8 49.47 0.0592 0.0 89.250 5.284 Vel = 7.91 M8 0.0 1.598 0.0 24.340 15.872 to 150.0 0.0 0.0 0.0 M7 49.47 0.0592 0.0 24.340 1.441 Vel = 7.91 M7 18.39 2.003 3N 33.0 47.540 17.313 to 150.0 0.0 33.000 0.0 M6 67.86 0.0354 0.0 80.540 2.850 Vel = 6.91 M6 56.92 2.003 N 11.0 2.330 20.163 to 150.0 0.0 11.000 0.0 TR3 124.78 0.1092 0.0 13.330 1.455 Vel = 12.70 TR3 0.0 2.203 E 5.0 10.250 21.618 to 120.0 B 6.0 11.000 4.439 BR3 124.78 0.1038 0.0 21.250 2.205 Vel = 10.50 BR3 0.0 4.31 T 20.0 29.000 28.262 to 120.0 E 10.0 30.000 4.223 S2 124.78 0.0039 0.0 59.000 0.232 Vel = 2.74 S2 0.0 4.31 3E 30.0 20.620 32.717 to 120.0 B 12.0 62.000 0.0 S3 124.78 0.0040 T 20.0 82.620 0.327 Vel = 2.74 S3 0.0 4.31 5E 50.0 53.830 33.044 to 120.0 T 20.0 70.000 0.0 1 124.78 0.0039 0.0 123.830 0.489 Vel = 2.74 1 0.0 4.31 2E 20.0 8.830 33.533 to 120.0 0.0 20.000 5.340 BF1 124.78 0.0040 0.0 28.830 0.114 Vel = 2.74 BFI 0.0 8.27 2E 47.88 10.000 38.987 to 140.0 Zid 0.0 47.880 8.314 * * Fixed Loss = 8.314 BF2 124.78 0.0001 0.0 57.880 0.007 Vel = 0.75 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 7 18433 STATE OF MIXED USE Date 9-11-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BF2 0.0 7.68 T 52.887 41.000 47.308 to 150.0 G 6.044 86.130 0.0 POC 124.78 0.0002 2F 27.199 127.130 0.020 Vel = 0.86 POC 0.0 9.42 T 75.553 52.000 47.328 to 150.0 0.0 75.553 0.0 UG1 124.78 0.0001 0.0 127.553 0.007 Vel = 0.57 UG1 0.0 11.2 0.0 209.490 47.335 to 150.0 0.0 0.0 -0.866 TEST 124.78 0.0 0.0 209.490 0.005 Vel = 0.41 250.00 Qa = 250.00 374.78 46.474 K Factor= 54.98 M2 43.72 1.598 0 8.0 14.620 10.563 to 150.0 0.0 8.000 0.0 M4 43.72 0.0471 0.0 22.620 1.065 Vel = 6.99 M4 -25.32 1.101 2R 2.0 90.500 11.628 to 150.0 0 5.0 7.000 0.0 M7 18.4 0.0583 0.0 97.500 5.685 Vel = 6.20 0.0 18.40 17.313 K Factor = 4.42 T5 -15.72 1.598 0.0 4.500 8.393 to 150.0 0.0 0.0 0.0 T6 -15.72 -0.0071 0.0 4.500 -0.032 Vel = 2.51 T6 15.84 1.598 0.0 5.210 8.361 to 150.0 0.0 0.0 0.0 T7 0.12 0.0 0.0 5.210 0.0 Vet = 0.02 17 15.84 1.598 0.0 4.830 8.361 to 150.0 0.0 0.0 0.0 T8 15.96 0.0072 0.0 4.830 0.035 Vel = 2.55 T8 15.88 1.598 R 1.0 1.470 8.396 to 150.0 0.0 1.000 0.0 Ml 31.84 0.0263 0.0 2.470 0.065 Vet = 5.09 0.0 31.84 8.461 K Factor= 10.95 T5 31.59 1.598 3N 27.0 97.250 8.393 to 150.0 R 1.0 28.000 0.0 M4 31.59 0.0258 0.0 125.250 3.235 Vel = 5.05 M4 25.32 1.598 0 8.0 14.620 11.628 to 150.0 0.0 8.000 0.0 M5 56.91 0.0767 0.0 22.620 1.736 Vel = 9.10 M5 0.0 1.598 0 8.0 71.580 13.364 to 150.0 N 9.0 17.000 0.0 M6 56.91 0.0768 0.0 88.580 6.799 Vet = 9.10 0.0 56.91 20.163 K Factor= 12.67 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 NEW Job Name 18433 State Mixed Use -FP DesignR2 Building FP-3 Location : ROOF LEVEL TOWER C System : 6 Contract : 18433 Data File : 18433 State Mixed Use -FP DesignR2 Area 7.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 18433 State Mixed Use -FP DesignR2 Date HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: ROOF LEVEL TOWER C Drawing no: FP-3 Date: 9-12-18 Design Remote area number: 6 Remote area location: ROOF ARCH. FEATURES Occupancy classification: LH Density: .1 - Gpm/SqFt Area of application: 1123 - SqFt Coverage per sprinkler: 200 - SqFt Type of sprinklers calculated: SSU QR 5.6 No. of sprinklers calculated: 6 In-rack demand: N/A - GPM Hose streams: 100 -GPM Total water required (including hose streams): 221.35 -GPM @ 71.64 - Psi Type of system: WET Volume of dry orpreaction system: -Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 State Mixed Use -FP DesignR2 Date City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 20.971 C2 - Residual Pressure: 25.5 D2 - System Flow :121.353 C2 - Residual Flow : 5725 D2 - System Pressure : 71.644 Hose ( Demand ) : 100 D3 - System Demand : 221.353 Safety Margin : 4.732 150 140 130 p120 R11° F10° s 90 S 80 U 70 R 60 D3 E 50 40 -- 30 -- : 02 : i_________________ U.I I I . 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. 18433 State Mixed Use -FP DesignR2 Page 3 Date Fitting Legend Abbrev. Name 1/ % 1 11/4 11/2 2 21,4 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345 Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 T NFPA139O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 3500A Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 State Mixed Use -FP DesignR2 Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 92.42 5.6 12.76 na 20.0 0.1 200 7.0 2 92.42 5.6 12.97 na 20.17 0.1 200 7.0 3 92.42 13.94 na 5 92.42 5.6 12.92 na 20.13 0.1 200 7.0 6 92.42 5.6 13.08 na 20.25 0.1 200 7.0 11 92.42 5.6 13.3 na 20.42 0.1 200 7.0 13 92.42 14.3 na 14 92.42 5.6 13.25 na 20.38 0.1 200 7.0 RB 87.42 16.59 na Ml 87.42 18.31 na M2 87.42 1935 na M3 87.42 19.45 na M4 87.42 31.69 na TR4 87.42 41.28 na BR4 77.17 47.81 na S2 54.33 57.92 na S3 54.33 58.23 na 1 54.33 58.7 na BF1 42.0 64.14 na BF2 42.0 72.48 na POC 42.0 72.5 na UG1 42.0 72.51 na TEST 44.0 71.64 na 100.0 The maximum velocity is 12.36 and it occurs in the pipe between nodes RB and Ml Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 State Mixed Use -FP DesignR2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 20.00 1.598 0.0 12.830 12.755 K Factor= 5.60 to 120.0 0.0 0.0 0.0 2 20.0 0.0168 0.0 12.830 0.215 Vel = 3.20 2 20.17 1.598 0 8.0 7.970 12.970 K Factor= 5.60 to 120.0 0.0 8.000 0.0 3 40.17 0.0609 0.0 15.970 0.972 Vel = 6.43 3 20.12 2.003 0.0 11.280 13.942 to 120.0 0.0 0.0 2.166 RB 60.29 0.0429 0.0 11.280 0.484 Vel = 6.14 0.0 60.29 16.592 K Factor = 14.80 5 20.13 1.101 0 5.0 4.860 12.917 K Factor =5.60 to 120.0 0.0 5.000 0.0 3 20.13 0.1040 0.0 9.860 1.025 Vel = 6.78 0.0 20.13 13.942 KFactor= 5.39 6 20.25 1.598 0.0 12.830 13.081 K Factor =5.60 to 120.0 0.0 0.0 0.0 11 20.25 0.0171 0.0 12.830 0.220 Vel = 3.24 11 20.43 1.598 0 8.0 7.970 13.301 K Factor =5.60 to 120.0 0.0 8.000 0.0 13 40.68 0.0623 0.0 15.970 0.995 Vel = 6.51 13 20.38 2.003 0.0 2.970 14.296 to 120.0 0.0 0.0 2.166 RB 61.06 0.0438 0.0 2.970 0.130 Vel = 6.22 0.0 61.06 16.592 KFactor= 14.99 14 20.38 1.101 0 5.0 4.860 13.246 K Factor =5.60 to 120.0 0.0 5.000 0.0 13 20.38 0.1065 0.0 9.860 1.050 Vel = 6.87 0.0 20.38 14.296 K Factor = 5.39 RB 121.35 2.003 N 11.0 5.540 16.592 to 150.0 0.0 11.000 0.0 Ml 121.35 0.1037 0.0 16.540 1.715 Vel = 12.36 Ml 0.0 2.003 0.0 10.040 18.307 to 150.0 0.0 0.0 0.0 M2 121.35 0.1037 0.0 10.040 1.041 Vel = 12.36 M2 0.0 2.003 0.0 1.000 19.348 to 150.0 0.0 0.0 0.0 M3 121.35 0.1040 0.0 1.000 0.104 VeI= 12.36 M3 0.0 2.003 0 10.0 86.000 19.452 to 150.0 2N 22.0 32.000 0.0 M4 121.35 0.1037 0.0 118.000 12.233 Vel = 12.36 M4 0.0 2.003 4N 44.0 48.500 31.685 to 150.0 0.0 44.000 0.0 TR4 121.35 0.1037 0.0 92.500 9.590 Vel = 12.36 TR4 0.0 2.203 E 5.0 10.250 41.275 to 120.0 B 6.0 11.000 4.439 BR4 121.35 0.0986 0.0 21.250 2.095 Vel = 10.21 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 State Mixed Use -FP DesignR2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BR4 0.0 4.31 T 20.0 29.000 47.809 to 120.0 E 10.0 30.000 9.892 S2 121.35 0.0037 0.0 59.000 0.221 Vel = 2.67 S2 0.0 4.31 3E 30.0 20.620 57.922 to 120.0 B 12.0 62.000 0.0 S3 121.35 0.0038 T 20.0 82.620 0.310 Vel = 2.67 S3 0.0 4.31 5E 50.0 53.830 58.232 to 120.0 T 20.0 70.000 0.0 T 121.35 0.0038 0.0 123.830 0.465 Vel = 2.67 T 0.0 4.31 2E 20.0 8.830 58.697 to 120.0 0.0 20.000 5.340 BF1 121.35 0.0037 0.0 28.830 0.108 Vel = 2.67 BFI 0.0 8.27 2E 47.88 10.000 64.145 to 140.0 Zid 0.0 47.880 8.327 * * Fixed Loss = 8.327 BF2 121.35 0.0001 0.0 57.880 0.007 Vel = 0.72 BF2 0.0 7.68 T 52.887 41.000 72.479 to 150.0 G 6.044 86.130 0.0 POC 121.35 0.0001 2F 27.199 127.130 0.019 Vel = 0.84 POC 0.0 9.42 T 75.553 52.000 72.498 to 150.0 0.0 75.553 0.0 UG1 121.35 0.0001 0.0 127.553 0.007 Vel = 0.56 UGI 0.0 11.2 0.0 209.490 72.505 to 150.0 0.0 0.0 -0.866 TEST 121.35 0.0 0.0 209.490 0.005 Vel = 0.40 100.00 Qa = 100.00 221.35 71.644 KFactor= 26.15 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 F.~Tlkinq ... Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 NEW Job Name : 18433 State Mixed Use -FP DesignR2 Building : FP-3 Location : ROOF LEVEL TOWER C System : 8 Contract : 18433 Data File : 18433 State Mixed Use -FP DesignR2 Area 8.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 TITAN FIRE PROTECTION, INC. Page 18433 State Mixed Use -FP DesignR2 Date HYDRAULIC CALCULATIONS for Project name: STATE MIXED USE 30 Location: ROOF LEVEL TOWER C Drawing no: FP-3 Date: 9-12-18 Design Remote area number: 8 Remote area location: ROOF ARCH. FEATURES Occupancy classification: LH Density: .1 - Gpm/SqFt Area of application: 923 - SqFt Coverage per sprinkler: 200 - SqFt Type of sprinklers calculated: SSU QR 5.6 No. of sprinklers calculated: 8 In-rack demand: N/A - GPM Hose streams: 100 -GPM Total water required (including hose streams): 265.52 - GPM @ 67.06 -Psi Type of system: WET Volume of dry or preaction system: -Gal Water supply information Date: 8-24-18 Location: SEE PLAN Source: CARLSBAD FIRE DEPARTMENT Name of contractor: 18433 Address: 2880 SOTT ST SUITE 105 Phone number: 760-295-3436 Name of designer: M.MARRON Authority having jurisdiction: CARLSBAD Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 2 18433 State Mixed Use -FP DesignR2 Date City Water Supply: Demand: Cl - Static Pressure : 76.5 Dl - Elevation : 20.971 C2 - Residual Pressure: 25.5 D2 - System Flow : 165.52 C2 - Residual Flow : 5725 D2 - System Pressure : 67.068 Hose (Demand ) :100 D3 - System Demand : 265.52 Safety Margin : 9.258 150 140 130 p120 R° E10° s 90 80 : U 70 R 60 D3 E 50 40 -- 30 -- _ I I I : I I . 750 1500 2250 3000 3750 4500 5250 6000 6750 FLOW (N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. Page 3 18433 State Mixed Use -FP DesignR2 Date Fitting Legend Abbrev. Name 1/ 3/4 1 11/4 11/z 2 21/2 3 3V2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 139O'StandardElbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA1345'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 N * CPVC 90'Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 T NFPA I39O' Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 3500A Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Length Units Flow Units Pressure Units Inches Feet US Gallons per Minute Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 4 18433 State Mixed Use -FP DesignR2 Date Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 15 92.42 5.6 12.76 na 20.0 0.1 200 7.0 16 92.42 5.6 12.83 na 20.06 0.1 200 7.0 17 92.42 5.6 13.26 na 20.39 0.1 200 7.0 El 92.42 14.52 na 18 92.42 14.92 na 20 92.42 5.6 12.81 na 20.04 0.1 200 7.0 21 92.42 5.6 13.98 na 20.94 0.1 200 7.0 E2 92.42 15.15 na 22 92.42 5.6 15.25 na 21.87 0.1 200 7.0 23 92.42 5.6 14.12 na 21.04 0.1 200 7.0 24 92.42 5.6 14.31 na 21.18 0.1 200 7.0 RC 92.42 16.21 na RC1 87.42 25.32 na TR4 87.42 34.34 na BR4 77.17 42.5 na S2 54.33 52.79 na S3 54.33 53.34 na T 54.33 54.16 na BF1 42.0 59.69 na BF2 42.0 67.88 na POC 42.0 67.91 na UG1 42.0 67.93 na TEST 44.0 67.07 na 100.0 The maximum velocity is 16.85 and it occurs in the pipe between nodes RC and RC1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 5 18433 State Mixed Use -FP DesignR2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C or Ftng's Fe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 15 12.81 1.598 0.0 10.170 12.755 K Factor =5.60 to 120.0 0.0 0.0 0.0 16 12.81 0.0074 0.0 10.170 0.075 Vet = 2.05 16 20.06 1.598 0.0 10.170 12.830 K Factor = 5.60 to 120.0 0.0 0.0 0.0 17 32.87 0.0420 0.0 10.170 0.427 Vet = 5.26 17 20.39 1.598 N 9.0 3.330 13.257 K Factor = 5.60 to 120.0 0.0 9.000 0.0 El 53.26 0.1026 0.0 12.330 1.265 Vet = 8.52 El 0.0 2.003 0.0 11.670 14.522 to 120.0 0.0 0.0 0.0 18 53.26 0.0342 0.0 11.670 0.399 Vet = 5.42 18 42.22 2.003 0 10.0 2.790 14.921 to 120.0 0.0 10.000 0.0 RC 95.48 0.1005 0.0 12.790 1.286 Vet = 9.72 0.0 95.48 16.207 K Factor = 23.72 15 7.19 1.598 N 9.0 12.170 12.755 to 120.0 0.0 9.000 0.0 20 7.19 0.0025 0.0 21.170 0.053 Vet = 1.15 20 20.04 1.598 N 9.0 30.580 12.808 K Factor =5.60 to 120.0 0.0 9.000 0.0 21 27.23 0.0297 0.0 39.580 1.174 Vet = 4.36 21 20.94 1.598 N 9.0 4.710 13.982 K Factor= 5.60 to 120.0 0.0 9.000 0.0 E2 48.17 0.0852 0.0 13.710 1.168 Vet = 7.71 E2 0.0 2.003 0.0 3.540 15.150 to 120.0 0.0 0.0 0.0 22 48.17 0.0282 0.0 3.540 0.100 Vet = 4.90 22 21.87 2.003 0 10.0 6.880 15.250 K Factor =5.60 to 120.0 0.0 10.000 0.0 RC 70.04 0.0567 0.0 16.880 0.957 Vet = 7.13 0.0 70.04 16.207 K Factor = 17.40 23 21.04 1.598 0.0 10.170 14.118 K Factor =5.60 to 120.0 0.0 0.0 0.0 24 21.04 0.0184 0.0 10.170 0.187 Vet = 3.37 24 21.18 1.598 0 8.0 1.220 14.305 K Factor =5.60 to 120.0 0.0 8.000 0.0 18 42.22 0.0668 0.0 9.220 0.616 Vet = 6.75 0.0 42.22 14.921 KFactor= 10.93 RC 165.52 2.003 2N 22.0 15.750 16.207 to 150.0 0.0 22.000 2.166 RC1 165.52 0.1841 0.0 37.750 6.949 Vet = 16.85 RCI 0.0 2.003 0 10.0 28.000 25.322 to 150.0 N 11.0 21.000 0.0 TR4 165.52 0.1841 0.0 49.000 9.021 Vet = 16.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams TITAN FIRE PROTECTION, INC. Page 6 18433 State Mixed Use -FP DesignR2 Date Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn TR4 0.0 2.203 E 5.0 10.250 34.343 to 120.0 B 6.0 11.000 4.439 BR4 165.52 0.1750 0.0 21.250 3.719 Vel = 13.93 BR4 0.0 4.31 T 20.0 29.000 42.501 to 120.0 E 10.0 30.000 9.892 S2 165.52 0.0067 0.0 59.000 0.393 Vel = 3.64 S2 0.0 4.31 3E 30.0 20.620 52.786 to 120.0 B 12.0 62.000 0.0 S3 165.52 0.0067 T 20.0 82.620 0.551 Vel = 3.64 S3 0.0 4.31 5E 50.0 53.830 53.337 to 120.0 T 20.0 70.000 0.0 T 165.52 0.0067 0.0 123.830 0.825 Vel = 3.64 T 0.0 4.31 2E 20.0 8.830 54.162 to 120.0 0.0 20.000 5.340 BF1 165.52 0.0067 0.0 28.830 0.192 Vel = 3.64 BF1 0.0 8.27 2E 47.88 10.000 59.694 to 140.0 Zid 0.0 47.880 8.174 * * Fixed Loss = 8.174 BF2 165.52 0.0002 0.0 57.880 0.011 Vel = 0.99 BF2 0.0 7.68 T 52.887 41.000 67.879 to 150.0 G 6.044 86.130 0.0 POC 165.52 0.0003 2F 27.199 127.130 0.034 Vel = 1.15 POC 0.0 9.42 T 75.553 52.000 67.913 to 150.0 0.0 75.553 0.0 UG1 165.52 0.0001 0.0 127.553 0.013 Vel = 0.76 UGI 0.0 11.2 0.0 209.490 67.926 to 150.0 0.0 0.0 -0.866 TEST 165.52 0.0 0.0 209.490 0.008 Vel = 0.54 100.00 Qa = 100.00 265.52 67.068 K Factor= 32.42 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - - - Fire Protection by Computer Design TITAN FIRE PROTECTION, INC. 2880 SCOTT ST. SUITE 105 VISTA, CA. 92081 760.295.3437 Job Name : STATE MIXED USE 30 Building Location System Contract Data File qT)WPPIPE CALG.,WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C TITAN FIRE PROTECTION, INC. Page 1 STATE MIXED USE 30 Date 12-4-18 City Water Supply: Demand: Cl - Static Pressure : 144.71 Dl - Elevation : 17.974 C2 - Residual Pressure: 0 D2 - System Flow C2 - Residual Flow : 750 D2 - System Pressure :144.713 Hose ( Demand) : 750 D3 - System Demand : 750 Safety Margin 150 U2 140 D3 130 p120 R 11 E10° S90 s 8° u 7° R6° E5° 40 30 20 Dl 10 - C2 100 200 300 400 500 600 700 800 900 FLOW ( N A 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary TITAN FIRE PROTECTION, INC. STATE MIXED USE 30 Page 2 Date 12-4-18 Fitting Legend Abbrev. Name /2 Y4 1 11/4 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O'FlowthruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. The diameter modification was turned off by the operator when the job was calculated. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD TITAN FIRE PROTECTION, INC. Page 3 STATE MIXED USE 30 Date 12-4-18 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Hi 89.5 100.0 na 250.0 H2 89.5 100.0 na 250.0 H3 91.5 117.66 na 250.0 TH3 91.5 121.99 na S2 54.17 138.97 na TH1 89.5 104.33 na Si 54.33 124.4 na S3 54.33 139.75 na FDC 48.0 144.71 na The maximum velocity is 13.98 and it occurs in the pipe between nodes Hi and TH1 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-WilIj!, TITAN FIRE PROTECTION, INC. Page 4 STATE MIXED USE 30 Date 12-4-18 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. .'C'.or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 250.00 2.703 EqI 31.0 0.250 100.000 Qa = 250 to 120.0 0.0 31.000 0.0 TH1 250.0 0.1386 0.0 31.250 4.331 Vel = 13.98 0.0 250.00 104.331 K Factor= 24.48 H2 250.00 2.703 EqI 31.0 0.250 100.000 Qa = 250 to 120.0 0.0 31.000 0.0 TH1 250.0 0.1386 0.0 31.250 4.331 Vet = 13.98 0.0 250.00 104.331 K Factor= 24.48 H3 250.00 2.703 EqI 31.0 0.250 117.655 Qa = 250 to 120.0 0.0 31.000 0.0 TH3 250.0 0.1386 0.0 31.250 4.332 Vel = 13.98 0.0 250.00 121.987 KFactor= 22.64 TH3 250.00 4.31 T 20.0 37.170 121.987 to 120.0 0.0 20.000 16.168 S2 250.0 0.0143 0.0 57.170 0.816 Vet = 5.50 S2 0.0 4.31 E 10.0 17.580 138.971 to 120.0 B 12.0 42.000 -0.069 S3 250.0 0.0143 T 20.0 59.580 0.851 Vel = 5.50 0.0 250.00 139.753 KFactor= 21.15 TH1 500.00 4.31 T 20.0 54.000 104.331 to 120.0 2E 20.0 40.000 15.232 Si 500.0 0.0515 0.0 94.000 4.842 Vel = 11.00 Si 0.0 4.31 8E 80.0 186.000 124.405 to 120.0 B 12.0 112.000 0.0 S3 500.0 0.0515 T 20.0 298.000 15.348 Vel = 11.00 S3 250.00 6.357 3E 42.0 61.000 139.753 to 120.0 S 32.0 74.000 2.742 FDC 750.0 0.0164 0.0 135.000 2.218 Vel = 7.58 0.0 750.00 144.713 K Factor= 62.35 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 I- 01TAN FIRE PROTECTION Fire Protection Contractor - License #989280 FIRE SUPRESSION MATERIAL SUBMITTAL STATE MIXED USE 30 3068 STATE ST. 3080 STATE ST, 542 OAK AVE. CARLSBAD, CA. 92008 CONTRACT NO. 18433 FPC20I8-0402 3068 STATE ST STATE AND OAK - STATE MIXED USE 30- NEW FIRE SPRINKLERS (576 HEADS) 2032970600 612612019 FPC20I8-0402 2880 Scott Street, Suite 105- Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax vi'w.titanfpinc.com Page Fire Protection Contractor - License #989280 TABLE OF CONTENTS SPRINKLERS OVERHEAD PIPE AND FITTINGS HANGERS AND SEISMIC ALARM DEVICES VALVES OTHER 2880 Scott Street, Suite 105 Vista, CA 92081 760-295-3881 - phone - 760-295-3437 - fax www.titanfpinc.com Page Page 1 of 6 NIKJNG4 MICROFASTO - QUICK RESPONSE PENDENT 1 SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast5' Quick Response Pendent Sprinkler VK302 is a small thermo- sensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE ([NT) coatings can be used in decorative applicationswhere colors are desired. In addition, these coatings have been investigated for installation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves ENT finish as corrosion resistant. FM Global has no approval classification for Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class Series 2000 FVd S1 VdS Aonroved: Certificates G414009 and G414010 LPCB Approved CE Certified: Standard EN 12259-1:1999, A3:2006 Certificate of Constancy of Performance 0832-CPR-50021 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length: 2-1/4" (58 mm) *cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 or Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sorinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135 °F (57 °C) = A, 155 °F (68 °C) = B, 175 °F (79 °C) = D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example, sprinkler VK302 with a Brass finish and a 155°F (68 °C) temperature rating = Part No. 12979AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the current Viking price list.) Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F_033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 'tJ II(JI'1G MICROFAST® QUICK lI.i:II[.flu'flf RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Wrenches: Standard Wrench: Part No. 21475M/13 (available since 2017). Wrench for Recessed Pendent Sprinklers: Part No. 13655W/B** (available since 2006) Optional Protective Sprinkler Cap Remover/Escutcheon Installer Tool*** Part No. 15915 (available since 2010) **A 1/2 ratchet is required (not available from Viking). ***Allows use from the floor by attaching a length of 1" diameter CPVC tubing to the tool. Ideal for sprinkler cabinets. Refer to Bulletin F_051808. Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfase Quick Response Pendent Sprinkler VK302 is available through a network of domestic and international dis- tributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat Protective Sprinkler Cap — 21475 Figure 1: Standard Sprinkler Wrench 21475M/B Form No. F 033314 17.10.05 Rev 17.2 1= Sprinkler wrench 13655W/B* for recessed pendent sprinklers ** A 1/2" ratchet is required (not available from Viking) Page 3 of 6 N41KING4 MICROFASP QUICK III[sflU'Yf RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature I Sprinkler Nominal I ' Maximum Ambient Bulb U Color Classification Temperature Rating' Ceiling Temperature Ordinary 135°F(57°C) 100°F(38°C) Orange Ordinary 155°F(68°C) 100°F(38°C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and [NT Corrosion-Resistant Coatings': White Polyester, and Black Polyester. ENT in all temperature ratings except 135 °F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verily through the end-user that the coatings are com- patible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. For ENT coated automatic sprinklers, the waterway is coated. Carefully slide the wrench sideways around the protective cap, ensuring engagement with the sprinkler wrench flats Figure 2: Wrench 13655W/B for Recessed Pendent Sprinklers Form No. F_033314 17.10.05 Rev 17.2 Page 4 of 6 NIKJNG* - MICROFAST® QUICK RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) The Viking Microfast Quick Response KEY Firfsh Pendent Sprinkler VK302 i FX, Escutcheon (if appkcabe) Maximum 175 PSI (12 Bar) WWP Base Sprinkler Thread Size Nominal Overall Listings and Approvals' Part SIN Style K-Factor Length (Refer also to Design Criteria.) Number' U.S. metric2 Inches mm cULus4 VdS LPCB 12979 VK302 Pendent 1/2' 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2, C2X Al A1Z, B1Y D1Z, C1Y - - 19780 VK302 Pendent 1/2" - 5.6 80.6 2-1/4 58 -- - -- -- -- D3 21354 VK302 Pendent -- 15mm 5.6 80.6 2-1/4 58 -- -- -- -- -- D3 - I 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 AIZ, B1Y, D2, C2X - -- -- -- 18021 VK302 Pendent 1/2' 15 mm 5.6 1 80.6 1 2-1/4 58 AiX, B1Y Al I AiX, B1Y I D1X, C1Y8 D1X, C1Y9 - Approved Temperature Ratings Approved Finishes Approved Escutcheons A - 135 OF (57 °C), 155 OF (68 °C), 175 OF 1 - Brass, Chrome, White X - Standard surface-mounted escutcheon or the (79 °C), 200 OF (93 °C), 286 OF (141 °C) Polyester' 6, Black Polyes- Viking Micromatic Model E-1 Recessed Escutcheon B - 135 OF (57 °C), 155 OF (68 °C), 175 OF ter56 Y - Standard surface-mounted escutcheon or the (79 °C), and 200 OF (93 °C) 2- ENT Viking Microfast Model F-i Adjustable Escutcheon, or recessed with the Viking Micro- C - 155 OF (68 °C), 175 OF (79 °C), and 3-Chrome matic' Model E-1, E-2, or E-3 Recessed Escutcheon 200 OF (93 °C) Z - Standard surface-mounted escutcheon or the D- 155°F (68 °C), 175°F (79 °C), 200°F Viking Microfast Model F-i Adjustable Escutcheon (93 °C), 286 OF (141 °C) Footnotes 1 Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. CE Certified, Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001. 8 CE Certified, Standard EN 12259-1, EC-certificates of conformity 0832-CPD-2001 and 0832-CPD-2003. MED Certified, Standard EN 12259-1, EC-certificates of conformity 0832-MED-1003 and 0832-MED-1008. DESIGN CRITERIA - UL (Also refer to Approval Chart I above.) cULus Listing Requirements: The Viking Microfast5 Quick Response Pendent Sprinkler VK302 is cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and stan- dards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 5 of 6 'J II(IIIG - MICROFAST® QUICK I:II[.1i..Yf RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature KEY The Viking Microfast Quick Response Fin:sh Pendent Sprinkler VK302 MX4— Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Base Part Sprinkler Thread Size Nominal K-Factor Overall Length FM Approvals3 Number' SIN Style (Refer also to Design Criteria.) NPT T BSP U.S. metric2 Inches mm 12979 VK302 Pendent 1/2' 15 mm 5.6 80.6 2-1/4 58 A1Z, 131Y, D2X, C2 Product Below Limited Availability ct Local Viking Office) 06662B VK302 Pendent 1/2" 15 mm 5.6 80.6 2-1/4 58 A1Z, B1Y, D2X, C2 18021 VK302 Pendent 1 1/2" 15 mm 5.6 80.6 2-1/4 1 58 A1Z,BIY Approved Escutcheons Approved Temperature Ratings X - Standard surface-mounted escutcheon or the A - 135 °F (57 °C), 155 °F (68 CC), 175 F (79 CC), 200 F Viking Micromatic Model E-1 Recessed (93 °C), 286 °F (141 °C) Approved Finishes Escutcheon B - 135 °F (57 AC), 155 °F (68 °C), 175 F (79 °C), and 1-Brass, Chrome, White Polyester', Y - Standard surface-mounted escutcheon or the 200 F (93 C) and Black Polyester' Viking Microfaste Model F-i Adjustable Escutcheon, C - 155 °F (68 AC), 175 F (79 CC), 200 ¶ (93 CC), 286 2 - ENT5 or recessed with the Viking Micromatica Model E-1 °F (141 °C) or E-2 Recessed Escutcheon D - 155 ¶ (68 °C), 175 °F (79 °C), 200 ¶ (93 C) Z - Standard surface-mounted escutcheon or the Viking Microfast5 Model F-i Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This table shows the FM Approvals available at the time of printing. Other approvals may be in process. Other colors are available on request with the same Approvals as the standard colors. FM approved as corrosion resistant. DESIGN CRITERIA -FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: The Viking Microfase Quick Response Pendent Sprinkler VK302 is FM Approved as quick response Non-storage pendent sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_033314 17.10.05 Rev 17.2 Page 6 of 6 MICROFAST® QUICK 44J II(IFs1Gj l.i:II[.1.u.YM RESPONSE PENDENT SPRINKLER VK302 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com 1/2" (15 mm) NPT 4 XK (45 mm) Installed with a standard 1/8" surface-mounted escutcheon Ceiling Opening Size: 2-5/16" (59 mm) minimum 2-1/2" (64 mm) maximum (54 mm) 4k 4k FL T II 2" (38 mm) (51 mm) L 2 1 Mm. Max. Installed with a Microfast Note: At maximum, adapter Model F-I Adjustable is exposed 1/2" (13 mm) Escutcheon from face of ceiling Figure 3: Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Ceiling Opening Size: 21/2" (64 mm) maximum 2-1/8" 2-1/8" jms4 4k II T II 4k 1-1/8" 4k Ii T 11 4k 1-1/8" 13/4" t( M it I (29 mm) 2" I\L4 I (29 mm) (4mm) jMin. (51 mm) jMin. Max. Max. + _ Installed with a Installed with a Model Model E-1 Recessed E-2 Thread-on Recessed Escutcheon Escutcheon Figure 4: Sprinkler Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_033314 17.10.05 Rev 17.2 Replaces Form No. F033314 Rev 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 4 II(JIII® MICROFASP QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION The Viking Microfast5 Quick Response Upright Sprinkler VK300 is a small, thermosensitive, glass-bulb spray sprinkler available in several differ- ent finishes and temperature ratings to meet design requirements. The spe- cial Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coat- ings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM global approves the ENT coating as corrosion resistant. FM Global has no approval classification Polyester coatings as corrosion resistant.) LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Classes 2002 and 2020 Refer to Approval Chart I and Design Criteria on for cULus Listing requirements and refer to Approval Chart 2 and Design Criteria FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)* Maximum Working Pressure: 175 psi (12 bar) wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing: U.S.A. Patent No. 4,831,870 Thread size: 1/2" NPT, 15 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric**) Glass-bulb fluid temperature rated to -65 OF (-55 "C) Overall Length: 2-3/16" (56 mm) 'cULus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi (0.35 bar). Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Viking Technical Data may be found on Deflector: Brass UNS-C23000 or Copper UNS-C19500 The Viking Corporation's Web site at Bulb: Glass, nominal 3 mm diameter http:llwww.viklnggroupinc.com. Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with The Web site may include a more recent PTFE Tape Screw: Brass UNS-C36000 edition of this Technical Data Page. Pip Cap and Insert Assembly: Copper UNS-ClI000 and Stainless Steel UNS- S30400 For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap - ENT plated Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfasttm Quick Response Upright Sprinkler VK300 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-M, Black Polyester = M-/B, and ENT = JN Temperature Suffix (°F/°C): 135°/57° = A, 155'/68° = B, 175°/79° = D, 200°/93' = E, and 286°/141° = G For example, sprinkler VK300 with a 1/2" NPT thread, Brass finish and a 155 °F/68 'C temperature rating = Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Standard Wrench: Part No. 10896W/13 (available since 2000) Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. Form No. F_052114 Rev 14.1 (New Page) Page 2 of 4 "\I Wj ® MICROFAST® QUICK lsill['1iUaYAfA RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Microfast Quick Response Upright Sprinkler VK300 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature 2 Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black PIFE. ENT in all temperature ratings except 135 F (57 °C) Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester, ENT, and PTFE coatings. For ENT coated automatic sprinklers, the waterway is coated. Protective Sprinkler Cap— Wrench Flat Figure 1: Standard Sprinkler Wrench 10896W/B Form No. F_052114 Rev 14.1 Page 3 of 4 NIIQNG*MICROFAST@ QUICK RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcscvikinqcorp.com - Approval Chart I (UL) Temperature KEY Microfast' Quick Response Finish AIX 4- Escutcheon (it applicable) Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 Number' SIN NPT BSP U.S. metric2 Inches mm cULus VdS LPCB 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, B2 - - - Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155 °F (68 °C) 175 °F (79 °C), 200 °F (93 °C), and - Brass, Chrome, White Polyester, and Black Polyester56 -F 286 (141-C)I 2-ENT6 B - 155 °F (68 °C), 175 °F (79 °C), 200°F (93 °C), and 286 °F (141°C) Footnotes 'Base part number is shown. For complete part number, refer to Viking's current price schedule. 2Methc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. Listed by Underwriters Laboratories Inc. for us in the U.S. and Canada Other colors are available on request with the same Listings and Approvals as the standard colors. 6 cULus Listed as corrosion resistant. DESIGN CRITERIA - UL (Also refer to Approval Chart 1 above.) cULus Listing Requirements: The Viking Microfast5 Quick Response Upright Sprinkler VK300 is cULus Listed as indicated in Approval Chart I for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 14.1 Page 4 of 4 MICROFAST® QUICK sj IF(II#IG l.l:II[1u.YM RESPONSE UPRIGHT SPRINKLER VK300 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY Microfasf Quack Response Finis f ) Escutcheon appIicabe Upright Sprinkler VK300 Maximum 175 PSI (12 bar) WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals3 Number" SIN (Refer also to Design Criteria below.) NPT BSP U.S. metric2 Inches I mm 12978 VK300 1/2' 15 mm 5.6 80.6 2-3/16 56 Al Approved Temperature Ratings Approved Finishes A- 135 °F (57 uC), 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and 286 "F (141"C) White Polyester5, and Black B - 155 "F (68 "C), 175 "F (79 "C), 200 "F (93 "C), and 286 "F (141"C) 2- ENT6 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 2 Metijc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the FM Approvals available at the time of printing. Check with the manufacturer for any additional approvals. Other colors are available on request with the same Approvals as the standard colors. 11 FM approved as corrosion resistant. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above) FM Anoroval Reauirements: The Microfast5 Quick Response Upright Sprinkler VK300 is FM Approved as a quick response Non-Storage upright sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM Installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QRI-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_052114 Rev 14.1 (New Page) Page 1 of 6 MICROFAST® QUICK N41KJNG4 1111ILRESPONSE HORIZONTAL IDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com DESCRIPTION The Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is a small thermosensitive glass bulb spray sprinkler available with various finishes and temperature ratings to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in Approval Charts. LISTINGS AND APPROVALS c®us cULus Listed: Category VNIV FM Approved: Class 2020 CCCF Approved: Approved by the China Certification Center for Fire Products (CCCF) Refer to Approval Charts and Design Criteria for listing and approval requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Rated to 175 psi (12 bar) water working pressure Factory tested hydrostatically to 500 psi (34.5 bar) Nominal K-Factor: 5.6 U.S. (80.6 metric*) * Metric K-factor measurement shown is when pressure is measured in Bar. Mien pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length: 2-3/4" (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 or QM Brass Deflector: Copper UNS-C19500 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coated Srrinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring - Exposed, Screw and Pip cap - ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 by first adding the appropriate suffix for the sprin- kler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome = F, White Polyester = M-M, Black Polyester = M-/B, and ENT = JN Temperature Suffix: 135°F / 57°C = A, 155°F / 68°C = B, 175 °F / 79°C = D, 200°F / 93°C = E, and 286°F / 141 °C = G For example, sprinkler 12997 with a Brass finish and a 155 °F / 68 °C temperature rating = Part No. 12997AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches: Standard Wrench: Part No. 21475M/B (available since 2017). Wrench for recessed and/or wax coated sprinklers: Part No. 13655W/B** (available since 2006) **A W ratchet is required (not available from Viking). Form No. F_060914 17.10.05 Rev 17.1 Replaces form F_060914 Rev. 16.2 (Replaced wrench 10896W/B with 21475M/B) Page 2 of 6 MICROFAST® QUICK RESPONSE HORIZONTAL N411UNG* I:II[.YU.7f. SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive fusible link disengages, the pip cap and spring are released, and the waterway is opened. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 is available through a network of domestic and interna- tional distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Wrench Flat.. 1 5. Figure 1: Standard Sprinkler Wrench 21475M1B Form No. F060914 17.10.05 Rev 17.1 Page 3 of 6 MICROFAST® QUICK NIIUNG I:Ius1u'yM :RESPONSE HORIZONTAL IDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color U Classification Temperature Rating' Ceiling Temperature' Ordinary 135°F(57°C) 100 °F(38°C) Orange Ordinary 155°F(68C) 100°F(38°C) Red Intermediate 175 F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 ¶ (107 °C) Blue Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-1 3. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. For ENT coated sprinklers, the waterway is coated. Note that the spring is exposed on sprinklers with Polyester, and ENT coatings. Step 1: Carefully slide the wrench sideways around the deflector, ensuring en- gagement with the sprinkler wrench flats. LW:-A, - Sprinkler wrench 13655W/B** must be used for installing wax coated sprinklers. **A 112" ratchet is required Step 2: Carefully press the wrench onto the (not available from Viking) sprinkler wrench flats. Figure 2: Wrench 13655W/B for Recessed Sprinklers Form No. F_060914 17.10.05 Rev 17.1 N Page 4 of 6 MICROFAST® QUICK :RESPONSE HORIZONTAL JIFII't'IG IDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart I (UL) Temperature KEY Microfast® Quick Response Horizontal Sidewall Sprinkler VK305 Finish iIx For Light or Ordinary Hazard Occupancies ± Escutcheon (if applicable) Maximum 175 PSI (12 Bar) WWP Deflector must be located 4" to 12" (102 mm to 305 mm) below the ceiling. - Base Part Sprinkler Thread Size Nominal K-Factor _______ Overall Length Listings and Approvals3 Number 1 SIN Style _______ _________ _______ (Refer also to Design Criteria on page 43x.) NPT BSP U.S. metric2 Inches mm cULus' LPCB 12997 VK305 HSW 1/2' 15 mm 5.6 80.6 2-11/16 68 AlY, BlX, -- -- -- 19782 VK305 HSW 1/2" -- 5.6 80.6 2-11/16 68 -- -- -- E3 ProductNOTICE elow -'Limited Availability ( AIL1TZ Office) 12121 VK305 HSW 1/2" 15 mm 5.6 80.6 1-11/16 68 AlY, BlX, -- -- -- Approved Temperature Ratings Approved Escutcheons A - 135 OF (57 'C), 155 OF (68 'C), 175 W- Installed with standard surface-mounted escutcheons OF (79 'C), 200 OF (93 'C), and 286 OF Approved Finishes X - Installed with standard surface-mounted escutcheons or (141 'C) 1 - Brass, Chrome, White Poly-esters,', the Viking Microfast Model F-i Adjustable Escutcheon, B - 135 OF (57 'C), 155 OF (68 'C), 175 OF and Black Polyester56 or recessed with the Viking Micromatic5 Model E-1, E-2, (79 'C), and 200 OF (93 'C) 2 - ENT' or G-1 Recessed Escutcheon C - 155 OF (68 'C), 175 OF (79 'C), 200 OF Y - Installed with standard surface-mounted escutcheons or (93 'C), and 286 OF (141 'C) 3 - Chrome the Viking Microfast® Model F-i Adjustable Escutcheon D - 155 OF (68 'C), 175 OF (79 'C), and 200 Z - Installed with standard surface-mounted escutcheons or OF (93 'C) recessed with the Viking Micromatic Model E-1 E - 155 OF (68 'C) Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3This table shows the listings and approvals available at the time of printing. Other approvals may be in process. Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. cULus Listed as corrosion-resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. DESIGN CRITERIA - UL (Also refer to Approval Chart 1.) cULus Listing Requirements: Quick Response Horizontal Sprinkler VK305 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. Designed for use in Light and Ordinary Hazard occupancies. Locate with the deflector 4" to 12' (102 mm to 305 mm) below the ceiling. Protection areas and maximum spacing shall be in accordance with the tables provided in NFPA 13. Minimum spacing allowed is 6 ft. (1.8 m). Align the top of the deflector parallel with the ceiling. Locate no less than 4" (102 mm) from end walls. Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers. The distance shall be measured perpendicular to the wall. The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard spray sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organiza- tions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F060914 17.10.05 Rev 17.1 Page 5 of 6 MICROFAST® QUICK NJ11aNG4 l.i:II[.1u.JM RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com Approval Chart 2 (FM) Temperature çy Quick Response Sidewall Sprinklers Finish IX4- A Escutcheon f (i applicable) Maximum 175 PSI WWP Base Part Thread Size Nominal K-Factor Overall Length FM Approvals'," Number' SIN (Refer also to Design Criteria below.) NPT BSP 1 U.S. metric2 Inches mm 12997 VK305 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y, B1X NOTICE)Product7!L7(l Availability ThTJ I1TP1ifl 12121 VK305 1/2" 15 mm 1 5.6 7 80.6 2-11/16 1 68 A1Y, B1X Approved Temperature Ratings Approved Escutcheons A- 135°F (57 °C), 155°F (68 °C), 175 X - Installed with standard surface-mounted escutcheons or the Viking OF (79 °C), 200 OF (93 °C), and 286 Approved Finishes Microfasta Model F-i Adjustable Escutcheon, or recessed with the OF (141 °C) 1 - Brass Viking Micromatic5 Model E-i, E-2, E-3, or G-i Recessed Escutcheon B - 135 OF (57 °C) 155 OF (68 °C), 175 Y - Installed with standard surface-mounted escutcheons or the Viking OF (79 °C), and 200 OF (93 °C) Microfasta Model F-i Adjustable Escutcheon Footnotes Base part number shown. For complete part number, refer to Viking's current price schedule. 2Mefflc K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 'This table shows the FM Approvals available at the time of printing. Other approvals may be in process. 4Viking vertical sidewall sprinklers may be installed pendent or upright. DESIGN CRITERIA - FM (Also refer to Approval Chart 2 above.) FM Approval Requirements: Horizontal Sidewall Sprinkler VK305 is FM Approved as a quick response Non-Storage sidewall sprinkler as indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to Bulletin Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_060914 17.10.05 Rev 17.1 Page 6 of 6 MICROFAST® QUICK '.1 I FII F'1Gi i:II[.1u'YM RESPONSE HORIZONTAL SIDEWALL SPRINKLER VK305 (K5.6) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page: www.vikinggroupinc.com H - H (62 mm) - 1j71/8 m " 21/8 ___ 1 2-518" __i 1 (67 mm) wow Maximum Wall Opening Size: Installed with a Standard Installed with a Microfast 2-5/16" (58.7 mm) minimum 1/8" Surface-Mounted Model F-I Adjustable 2-1/2" (63.5 mm) maximum Escutcheon Escutcheon Figure 3: Sidewall Sprinkler Dimensions with a Standard Escutcheon and the Model F-I Adjustable Escutcheon Minimum Minimum 1-5/8" 1-3/4" Ef (45 mm) 4 I 21/8 •i (54 mm) 2-1/4" - 2-5/8" (57 mm) (67 mm) Maximum Maximum Wall Opening Size: Installed with the Installed with the 2-5116" (58.7 mm) minimum Micromatic Model Bi Threaded Model E-2 2-1/2" (63.5 mm) maximum Recessed Escutcheon Recessed Escutcheon Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_060914 17.10.05 Rev 17.1 Replaces form F_060914 Rev. 17.1 (Replaced wrench 10896W/B with 21475M/B) Page 1 of 5 II[s1iUD7f CONCEALED PENDENT - FREEDOM® RESIDENTIAL A SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 4.9 (70.6 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two- piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2" (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-U L- US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW u Refer to the Approval Charts and Design Criteria on for C-UL-US-EU Listing requirements that must be followed. TECHNICAL DATA Specifications: Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) Glass-bulb fluid temperature rated to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze U NS-051 000 Deflector Pins: Stainless Steel UNS-S30200 Button: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and SS UNS-S30400 Compression Screw: 18-8 Stainless Steel Yoke: UNS-543000 Stainless Steel or Phosphor Bronze UNS-051000 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape CoverAdapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom® Residential Concealed Pendent Sprinkler VK494 and Cover Plate Assembly must be ordered separately: Sprinkler: Order Sprinkler VK494 by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A and ENT = JN Temperature Suffix: 155 °F (68 °C) = B, 200 *F (93 °C) = E For example, sprinkler VK494 with a Brass finish and a 200 °F (93 °C) temperature rating = Part No. 20759AE. Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), or Base Part No. 15394 (square cover plate, 3-5/16" diameter) Form No. F_012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) Page 2 of 5 S.J II(JIs1G. FREEDOM® RESIDENTIAL II[rU.7M CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-NV, Painted Ivory = M-/I, Painted Black = M-/B Temperature Suffix: 135 °F/57 °C = A For example, cover 13504 with a Polished Chrome finish and a 135 °F/57 °C temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the Viking website.) Sprinkler Wrenches**: Heavy Duty Part No. 14047W/B** (available since 2006), or Head Cabinet Wrench Part No. 14031*** (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a 1/2' ratchet (not available from Viking). ***Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand, causing the glass to shatter, releasing the yoke and pip cap and sealing spring assembly. . Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pres- sure at the sprinkler to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. f..]I 1WVL1lW:lI* iURE RATINGSYANDIllFINISHES Id Sprinkler Sprinkler Maximum Temperature Rating Cover Large Square Temperature Nominal Ambient of the Cover Plate Cover Plate Cover Plate Bulb Color Classification Temperature Ceiling Assembly Base Part Base Part Base Part Rating' Temperature' (Required)3 Number' Number' Number' Ordinary 155 °F(68°C) 100°F(38°C) 135°F(57°C) 13504 13642 15394 Red Intermediate 200 °F(93°C) 150°F(65°C) 135°F(57°C) 13504 13642 15394 Green Sprinkler Finishes: Brass and ENT Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings': ENT Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Maximum ambient temperature for cover assembly is 100 F (38 °C). Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Form No. F012116 17.04.20 Rev 17.2 Page 3 of 5 S4 FREEDOM® RESIDENTIAL mfl CONCEALED PENDENT J II(II1G® - - i[sliU f SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Approval Chart Viking VK494, 49 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 1313 or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Wor- Part Number SIN king Pressure Inches mm U.S. metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (l2bar) Max Coverage Flow Pressure Listings and Minimum 6 Area WXL GPM (LPM) PSI (bar) Deflector to Installation Approvals',' Spacing Ceiling Type Ft. 155°F(68°C), 200°F(93°C)Temperature ®us ' Ft. X Ft. (m) (m X m) Rated Sprinklers 12X12 13 7.0 (3.7 X 3.7) (49.2) (0.48) 14X14 13 7.0 (4.3X4.3) (49.2) (0.48) RefertoFigure2 Concealed with Cover Plate See Footnotes T1 0, & 11 8 16 X 16 13 7.0 (4.9X4.9) (49.2) (0.48) Assembly. See Footnote 9. (2.4) 18 X 18 17 12.0 (5.5 X 5.5) (64.4) (0.83) 20X20 20 16.7 (6.1X6.1) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to current Viking price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure" used. Cover Temperature Rating is 135 "F (57 °C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 10 Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 1. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) Form No. F012116 17.04.20 Rev 17.2 Page 4 of 5 'sj II(II1G - FREEDOM® RESIDENTIAL II[s1ip7WA CONCEALED PENDENT SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com DESIGN CRITERIA (Also refer to the Approval Chart on page 3.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpmlsq. ft. over the 'design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in- stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly Protective cap removed Use wrench 14047W/B** 2-1/4" (57 mm) diameter opening required in the ceiling. Sprinkler Wrench . Part No. 14047W/B** Step 1: Step 2: t t Carefully slide the Carefully press the wrench upward and wrench sideways around turn slightly to ensure engagement with the deflector and pins the sprinkler wrench flats. NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise Ito 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms Figure 1: Sprinkler Installation and Proper Wrench Usage ** A 1/2" ratchet is required (Not available from Viking) Form No. F012116 17.04.20 Rev 17.2 2-1/16" (52 mm) Minimum 2-9/16" (65 mm) Maximum 1/2" (15 mm) NPT Page 5 of 5 FREEDOM® RESIDENTIAL DATA I CONCEALED PENDENT \J W*j - SPRINKLER VK494 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com 2-3/4" (70 mm) or NOTE: Upon sprinkler activation, the deflector descends 3-5/16" (84 mm) to approximately 13/16" (21 mm) below the sprinkler body. Figure 2: Sprinkler Dimensions and Cover Installation -- / c-) \\ NIKING I All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 3: Identification of Custom Paint for Concealed Covers , Figure 4: Square Cover Assembly 15394 Form No. F_012116 17.04.20 Rev 17.2 Replaces Form No. F_012116 Rev 17.1 (added alt. material for yoke) Page 1 of 6 "i lI(ItIG® FREEDOMS RESIDENTIAL lii:Il[.1iu.7fA CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK468 is a small high sensitivity glass bulb residential sprinkler for use with a domed cover assembly. The orifice design with a K Factor of 4.9 (70.6 metric*) allows the sprinklers ef- ficient use of available water supplies for the hydraulically designed fire-protection system. The glass bulb operating element and special deflector characteristics . ., ...-. - meet the challenges of residential sprinkler standards .4 Concealed sprinkler VK468 is pre-assembled with a threaded adapter for instal- . lation with the domed cover that provides up to %" (12.7 mm) of vertical adjust-:- ment The cover plate is available with several decorative finishes to meet design - requirements The two-piece design allows installation and testing of the sprinkler . prior to installation of the cover plate The"push-on",thread off design of the ... concealed cover plate assembly allows easy installation of the cover plate after the ,. system has been tested and the ceiling finish has been applied The cover assem- bly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as corrosion resistant as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. LISTINGS AND APPROVALS UL Listed (C-UL-US-EU): Category VKKW W NYC Approval: MEA 89-92-E, Volume 35 UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). Refer to the Approval Charts and Design Criteria for C-UL-US-EU Listing requirements that must be followed. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure: Refer to the Approval Charts. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 4.9 U.S. (70.6 metric*) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to -65 °F (-55 °C) Overall Length (Sprinkler Body): 2-1/4" (58 mm) Viking Technical Data may be found on Material Standards: The Viking Corporation's Web site at Frame Casting: Brass UNS-C84400 or QM Brass http:!!www.vikinggroupinc.com. Deflector: Brass UNS-C23000, Phosphor Bronze UNS-051000, or Brass The Web site may Include a more recent UNS-C26000 edition of this Technical Data Page. Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Compression Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-530400 Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Cover Assembly Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Residential Concealed Pendent Sprinkler VK468 and Cover Plate Assembly must be ordered separately: Sprinkler: Base Part Nos. 13637A-X for Brass finish and 13637JN-X for ENT finish (includes sprinkler and adapter pre-assembled, with a protective plastic cap covering the unit) Form No. F_020206 Rev 14.1 (Added EU Listing) Page 2 of 6 41KJOO FREEDOM@ RESIDENTIAL CONCEALED PENDENT . N SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Rating: 155 "F (68 "C) = 8, 175 °F (79 "C) = D For example, concealed sprinkler VK468 with a 155 "F (68 "C) temperature rating = Part No. 13637ABX Note: When ordering this sprinkler using the SIN, add suffix -0. For example, concealed sprinkler VK468 = VK468-D. Cover Plate Assembly: Base Part No. 12207 Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-IB, Painted White = M-M( Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135°F (57 "C) =A For example, cover 12207 with a Polished Chrome finish and a 135 "F (57 °C) temperature rating = 12207FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Part No. 13577W/B** (available since 2006) ""A 'A" ratchet is required (not available from Viking). Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand and the bulb to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Model VK468 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of the Cover Plate Bulb Classification Temperature Rating' Ceiling Temperature Cover Assembly (Required) Base Part No3 Color Ordinary 155°F(68°C) 100"F(38"C) 135°F(57"C) 12207 Red Intermediate 175 OF (79 "C) 150 "F (65 "C) 135 "F (57 "C) 12207 Yellow Sprinkler Finishes: Brass or ENT (See Ordering Information section) Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Corrosion Resistant Coatings4: ENT Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NPFA 130. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 4 The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. Form No. F_020206 Rev 14.1 Page 3 of 6 'sj II(IIl6i® FREEDOM® RESIDENTIAL l:II[.nu.yIy6 CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart I Viking VK468, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 130 or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13,13R or 130 2013 Editions Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Overall Length Part Number' SIN Working Pressure Inches mm U.S. metric2 Inches mm 13637A-X VK468 1/2 15 4.9 70.6 175 psi (12 bar) 2-1/4 58 Max. Coverage Ordinary Temp Rating (155 °F168 °C) Intermediate Temp Rating (175 °F179 °C) Listings and Approvals' Minimum Area8 Deflector Installation Spacing FtX Ft Flow8 Pressure' Flow' Pressure8 to Ceiling Type 4 Ft. (M M) GPM PSI GPM PSI c)Us NYC5 NSF (m) (L/min) (bar) (L/min) (bar) 12 X 12 1.3 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) 14X14 13 7.0 13 7.0 (4.3 X 4.3) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Concealed with See Foot- See Foot- See Foot- 8 16X 16 13 7.0 13 7.0 (4.9 X 4.9) (49.2) (0.48) (49.2) (0.48) inch Cover Plate Assembly. note 6 and 9. note 6 and 9. note 6 and 9. - (2.4) 18X18 17 12.0 17 12.0 (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) 20X20 20 16.7 20 16.7 (6.1X6.1) (75.7) (1.15) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 35. 6 Cover Temperature Rating is 135 "F (57 "C). UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure" used. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 11. ° Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufac- turer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 2. Form No. F_020206 Rev 14.1 Page 4 of 6 'sj II(IIIGi FREEDOM® RESIDENTIAL l:II[.1iu.Jf CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart 2 Viking VK468, 4.9 K-Factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 13D 2013 Editions Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Overall Length Part Number' SIN Working Pressure Inches mm U.S. metric2 Inches mm 13637JN-X9 VK468 1/2 15 4.9 70.6 175 psi (12 bar) 2-1/4 58 Max. Coverage Ordinary Temp Rating (155 °F168 °C) Intermediate Temp Rating (175 °F179 °C) Listings and Approvals3 Minimum Area6 Deflector Installation Spacing FtX Ft Flow6 Pressure' FIow6 Pressure' to Ceiling Type C-UL- Ft (m X m) GPM PSI GPM PSI US- NYC NSF (m) (L/min) (bar) (L/min) (bar) EU4 12X12 13 7.0 13 7.0 (3.7 X 3.7) (49.2) (0.48) (49.2) (0.48) 14X14 13 7.0 13 7.0 (4.3 X 4.3) (49.2) (0.48) (49.2) (0.48) 3/8 to 7/8 Concealed with See Foot- 8 16 X 16 13 7.0 13 7.0 (4.9 X 4.9) (49.2) (0.48) (49.2) (0.48) inch Cover Plate Assembly. note 5 and 7. -. - (2.4) 18X18 17 12.0 17 12.0 (5.5 X 5.5) (64.4) (0.83) (64.4) (0.83) 20X20 20 16.7 20 16.7 (6.1X6.1) (75.7) (1.15) (75.7) (1.15) Footnotes Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter's Laboratories, Inc. for use in the U.S. and Canada. Cover Temperature Rating is 135 F (57 "C). 6 For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure" used. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 8 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufac- turer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 2. C-UL-US-EU Listed as corrosion resistant. Form No. F_020206 Rev 14.1 Page 5 of 6 1II(II1Gi® - FREEDOM® RESIDENTIAL l.l:II[s1..flf CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESIGN CRITERIA (Also refer to the Approval Charts) UL Listing Requirements (C-UL-US-EU: When using Viking Residential Concealed Pendent Sprinkler VK468 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Charts. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Charts for NFPA 13D and NFPA 13R applications for each listed area of coverage, or Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the "design area' in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). DEFLECTOR POSITION: Install Residential Concealed Pendent Sprinkler VK468 with the deflector 3/8" (9.5 mm) to 7/8" (22.2 mm) below the ceiling. Refer to Figure 3. NOTE: Concealed sprinklers must be installed In neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RESI-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler N and Adapter " Assembly Protective Sprinider Shek Figure 1: Concealed Sprinkler VK468 with Protective Shell cusTo4 ((0)) Identification of Custom Paint Color: All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates custom color and will have a representative sample (a paint clot) of the paint on the label. Figure 2: Identification of Custom Paint Color for Concealed Covers Form No. F_020206 Rev 14.1 1-3/8" (34.3 rim) Minimum J1-7/8' I(47 mm) Maximum 2-5/8' (66.7 mm) diameter opening required in i.. the ceiling. Sprinkler and Adapter Assemb (Protective Sh Removed for Installation,) Step 1: Carefully slide the wrench sideways around the deflector Wr ench Flat Sprinklei 13577\J/ he us instatUng Sprinkle **A 1/2' ratchet is required (not available from Viking), Li tep 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Page 6 of 6 "J II(IF1G® - FREEDOM® RESIDENTIAL l.1:ll['flu'7f CONCEALED PENDENT SPRINKLER VK468 (K4.9) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Figure 3: Sprinkler Dimensions and Cover Installation Figure 4: Sprinkler Installation and Correct Use of Sprinkler Wrench Form No. F_020206 Rev 14.1 (Added ELI Listing) The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems in commercial and residential construction, Bull Moose Tube has added Eddy Flow to its comprehensive line of sprinkler pipe products. Eddy Flow is a specially engineered replacement for schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL listed (for U.S. and Canada) for roll grooving and welding for use in fire protection COMPARISON systems with a working pressure of 300 psi or less. Please check with appropriate sources for up-to-date listings and approval information. As an added benefit, it is more economical to use than schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's larger ID provides an opportunity for downsizing and further cost savings. I FJ STEEIjEjjjE C4jT* INU—minal Pipe . W(i Wn W(i Wn low ule4OWSOET(iff 1 1/4 1.660 1.530 1.442 1.380 1.98 1.00 1 1/2 1.900 1.728 1.682 1.610 3.44 1.00 2 2.375 2.203 2.157 2.067 2.78 1.00 21/2 2.875 2.705 2.635 2.469 1.66 1.00 3 3.500 3.334 3.260 3.068 1.00 1.00 4 4.500 4.310 4.260 4.026 1.00 1.00 * Corrosion Resistance Ratio Dual Certified to ASTM A135 and A795. FM Approved for roll grooved, and welded, and plain-end application in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. UL Listed (for US and Canada) and FM Approved for use with Victaulic® Fllw Fittings in plain end applications. Lightweight - saves shipping costs, and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Floor stock available in various lengths produced in Casa Grande (AZ), Gerald (MO), and Masury (OH). Also can be ordered in custom lengths.. Can be used for wet and dry* systems. * Eddy Flow can be hot dipped galvanized to meet FM's requirement for dry systems. PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, c®us 4 A&I (N 6 Chesterfield, MO 63017 contact your salesperson today at LISTED (800) 325-4467 (800) 325-4467 or (636) 537-2600 8 EULJ.. MOOSE TUBE O(V ANY FAX: (636) 537-2645 in the USA, or from Canada -4e> ______ www.bullmoosetube.com call (800) 882-4666 ACfiERcompany e-mail:sa1es@bu1Imoosetube.com AMOVIED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-I 35 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS IM=%ff@@M"j &Do I ai am 11 @MI 1 1.461 1.083 70 1 1/4 2.070 1.418 51 I 1/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 11/4 1.00 1.00 11/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, 6 Chesterfield, MO 63017 contact your salesperson today at (800) 325-4467 (800) 325-4467 or (636) 537-2600 USTED A 3 BULL. MOOSE TUBE COMPANY FAX: (636) 537-2645 in the USA, or from Canada A CRO company e-mail:sa1es()bu11nioosethbe.com www.bullmoosetube.com call (800) 882-4666 <~> APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 As the leading supplier of steel sprinkler pipe, we understand that there are no second chances in fire suppressior. You need products of enduring quality and exceptional strength—plus reliable service. You need Bull Moose. Bull Moose Fire Sprinkler Pipe Product f)j[i] ' 1 H11 •:1 1 ______ i i'•i 1.650 1.900 2.315 I.D. (in) 1.083 1.418 1.654 2.123 Ernpfl/ Weight (lb/It) 1.461 2.070 2.547 3.308 ki Water Filled Weight (lb/It) 1.860 2.754 3.468 4.842 -I OR (in)1.295 - CROft I 1.00 1.00 1.00 1.00 Pieces per Lift 70 51 44 30 - Lift weight (Ibs) 21 lengths 2,148 2,217 2,353 2,094 Lift Weight (Ibs) 24' lengths 2,454 2,534 1 2,690 1 2,382 Lift Weight (Ibs) 25' lengths 2,557 2,639 1 2,802 1 2,491 EMYNDEAD 40 ADVANTAGES: UL listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with NFPA-13, 13R and 14 1 • Industry-Leading hydraulic characteristics CRR of 1.0 and greater \. All pipe NDT weld tested OTNER DEWERTS/sEMEES: We have the most stocking locations in the industry, for best delivery and availability Plain end or roll groove Eddy Guard II" bacterial-resistant internal coating Custom length options Hot dipped galvanization Reddi-Pipe® red or black pipe eliminates field painting Compatible for use in wet, dry, preaction and deluge sprinkler systems The only maker with EPDs (to help earn LEED points). N 0o ONFSA c®us LISTED (] .4 APPROVED NFPA As the leading supplier of steel sprinkler pipe, we undes:and t-at there are r:J seccnd chEnces in tire suppression. You need products of enduring quaity and exceptional strength—plus reliable service. You need Bu[l Moose. Bull Moose Fire Sprinkler Pipe Product information GD (in) 1.660 1.903 2,375 Z975 I 3.00 4.513 I.D. (in) 1.530 1.720 21C 3 2.1)5 2-134 4.310 Eniptv Weight (lb/ft) 1.222 'L844 2.333 2 839 3J1 4.953 Water Filled Weight (ltjitl 2.019 2.860 1 3.962 5299 7.44 11.290 C.R.R. 1.98 3.44 10 1.66 1.30 1.00 - Pieces per Lift 61 61 37 30 9 19 - Lift Weight (Ibs( 21 lergcar 1,565 1 Z,362 i 1,310 1,170 1,341 1,932 Lift Weight (Ibs) 24' lergths 1,189 .700 2069 2.322 1,33 2,25; Lift Weight (Ibs) 25' lenetr; 1,864 2,812 1 2,155 2,131 1,595 1 2,360 EDDY FLOW I41ThGES: UL listed (US & Canada) and FM approved ASTM A135 and A795 Type E, Grade A Certified Complies with NFPA-13 13R and 14 Industry-leading hydrauLic characteristics CRR of 1.0 and greater All pipe NDT weld tested E3lEJTS/SEtflCES: We havet -e mcst stocdng Locations H the industry, for best deLi and a'.aiLability Pa.n end or roll groove Eddy Guard II'bcteriaL-esistant irenatcoatirg Custom leigth options I-Ic: dipped gakaiization Reddi-Ppe redcr.b[acK pipe eliminates field painting Compatible for use in wet, dry, pea:ticn and deluge spr;nk1ersstems The only maker with EDs (to help earn LEED points). c®s LISTED tqCU /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet An rapid response HOME FIRE SPRINKLER SYSTEM General Description Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, Janu- ary 2005 "Installation Instruction & Technical Handbook" for exact list- ing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMaster is a registered trademark of Noveon IP Holding Corp. Page 1 of 6 JANUARY, 2006 TFPI9I5 Page 2 of 6 TFPI9I5 NOMINAL AVERAGE AVERAGE WEIGHT FILL WATER ED WEIGHT FT. OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. lbs/ft. lbs/ft PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1" 1.315" 1.101' 0.26 0.67 5040 1320 1-1/4" 1.660" 1.394' 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2' 2.375" 2.003' 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3" 3.500" 2.952" 1.87 4.83 720 1344 FIGURE 1— PIPE DIMENSIONS Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with IH-1900, Rev. 0, January 2005 "Installation Instruction & Techni- cal Handbook". Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFPI9IS Page 3 of 6 FITTING PART NOMINAL TAKE-OUT WEIGHT NOMINAL SIZE s SCHD . TYPE NUMBER (TIO) (lb.) TEE 80000 3/4 5181, 40 0.11 80001 11/16' 40 0.19 I 80002 1-1/4" 7/8" 40 0,26 -t-: 1/0 80003 1-1/2" 1-1/16" 80 0.51 ___80004 1-3/8' 80 0.90 //80005 ~~=T/O 2-1/2" 1-9/16" 80 1.59 T/0 80006 1-13/16" 80 2.41 XxYxZ X Y Z 3/4" x 3/4" x 1" 3/4" 3/4" 5/8" 80132 40 0.14 80133 1"x3/4"x3/4" 9/16" 9/16" 3/4' 40 0.14 80134 1" x 3/4" x 1" 3/4" 11/16" 3/4" 40 0.17 80260 x 1" x 3/4" 5/8" 5/8" 13/16" 40 0.16 80135 1-1/4" xix 3/4" 5/8" 5/8" 15/16" 40 0.21 80136 1-1/4" xl" xl" 3/4" 3/4" 15/16" 40 0.22 80137 1-1/4" x 1" x 1-1/4" 15/16" 15/16" 7/8" 40 0.26 REDUCING TEE 80261 1-1/4" x 1-1/4" x 3/4" 5/8" 5/8" 7/8" 40 0.23 80262 1-1/4" x 1-1/4" x 1" 3/4" 3/4" 7/8" 40 0.26 80138 1-1/4" x 1-1/4" x 1-1/2" 1" 1" 1" 80 0.43 T/0 80140 1-1/" x 1-1/4" x 3/4" 2 9/16" 9/16" 1" 80 0.36 80141 1-1/2" x 1-1/4" xl" 9/16" 9/16" 1-1/16" 80 0.38 80263 80264 1-1/2" x 1-1/2" x 3/4" 1-1/2" x 1-1/2' x 1" 9/16" 9/16" 9/16" 9/16" 1" 1-1/16" 80 80 0.36 0.38 X Y ±1 80275 1-1/2" x 1-1/2" x 1-1/4" 7/8" 7/8" 1" 80 0.45 T/0 TIO 80265 x 2" x 3/4" 3/4" 3/4" 1-3/8" 80 0,61 80266 2" x 2" x 1" 7/8" 7/8" 1-3/8" 80 0,66 80274 2" x 2" x 1-1/4" 1-1/16" 1-1/16" 1-3/8" 80 0.74 80267 2" x 2" x 1-1/2" 1-1/8" 1-1/8" 1-3/8" 80 0.78 80271 2-1/2" x 2-1/2" x " 1-9/16" 1-9/16" 1-9/16' 80 1.43 80272 2-1/2" x 2-1/2" x 1-1/4" 1-9/16" 1-9/16" 1-9/16" 80 1.46 80273 2-1/2" x 2-1/2" x 1-1/2" 1-9/16" 1-9/16" 1-9/16" 80 1.48 80276 2-112"x2-112"x2" 1-9/16" 1-9/16" 1-9/16" 80 1.50 80270 3" x 3" x 1-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.28 80268 3" x 3" x 2" 1-13/16" 1-13/16" 1-3/4" 80 2.25 80269 3" x 3" x 2-1/2" 1-13/16" 1-13/16" 1-13/16" 80 2.44 CROSS & REDUCING CROSS 80009 3/4" 9/16" 40 0.13 80010 11/16" 40 0.23 T/0 80011 1-1/4" 15/16" 40 0.34 80012 1-1/2" 1-1/16" 80 0.67 80013 1-5/16" 80 1.00 80014 2-1/2" 1-9/16" 80 1.91 t ____ TIO 80008 1-13/16" 80 2.89 80015 1" x lx 3/4" x 3/4" 7/8" 40 0.28 1/1/0 80025 3/4" 5/8" 40 0.09 9O ELBOW & REDUCING ELBOW 80026 3/4" 40 0.14 80027 1-1/4" 7/8" 40 0.21 X 80028 1-1/2" 1-1/16" 80 0.40 H H 1/0 80029 1-5/16" 80 0.79 80030 2-1/2" 1-9/16" 80 1.14 80031 1-13/16" 80 1.82 XxY X Y 1/0 80032 lx 3/4" 11/16" 13/16" 40 0.16 FIGURE 2- FITTING DIMENSIONS (Part I of 4) Page 4 of 6 TFPI9I5 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE (TIO) SCHD. (lb.) 45" ELBOW 80050 3/4" 3/8" 40 0.08 80051 3/8" 40 0.11 80052 1-1/4" 3/4" 40 0.20 80053 1-1/2" 1/2" 80 0.31 80054 3/4" 80 0.56 T/O 80055 2-1/2" 13/16" 80 0.89 80056 1" 80 1.19 80075 3/4" 1/8" 40 0.07 COUPLING & 80076 1/8" 40 0.11 REDUCING COUPLING 80077 1-1/4" 3/16" 40 0.12 80078 1-1/2" 3/16' 80 0.25 80079 3/16" 80 0.38 TT/O 80080 2-1/2" 1/4" 80 0.67 80081 3/16" 80 0.91 80220 1" x3/4" 1/8' 40 0.08 80200 x 3/4" 7/16" 40 0.04 80201 1-1/4"x3/4" 1/2" 40 0.11 80202 1-1/4" x1" 5/16" 40 0.12 80203 1-1/2" x 3/4" 5/8" 80 0.16 80204 1-1/2" x1" 1/2" 80 0.14 REDUCER BUSHING 80205 1-1/2" x 1-1/4" 3/8" 80 0.17 80206 x 3/4" 13/16" 80 0.27 80207 2" x1" 11/16" 80 0.26 ~;T/O 80208 2' x 1-1/4" 9/16' 80 0.24 80209 2' x 1-1/2" 7/16" 80 0.42 8 2-1/2" x1" 0.19 0215 15/16" 80 80214 2-1/2" x 1-1/4" 13/16" 80 0.45 80213 2-1/2" x 1-1/2" 11/16" 80 0.46 80211 2-1/2" x 2" 5/8" 80 0.29 80210 3" x 2" 3/4" 80 0.72 80212 3" x 2-1/2" 1/2" 80 0.47 CAP 80100 3/4" 5/16" 40 0.04 80101 3/8" 40 0.06 1-1/4" 7/16" 40 0.10 80103 1-1/2" 11/16" 80 0.20 PL 80102 80104 5/8" 80 0.31 80105 2-1/2" 7/8" 80 0.58 80106 1" 80 0.88 GROOVED TiO PIPE O.D. COUPLING ADAPTER 80160 1-1/4" x 1-1/4" Groove 2-5/16" 1-1/4" (1.660") 40 0.78 80161 1-1/2" x 1-1/2" Groove 2-5/16" 1-1/2" (1.900") 80 0.95 PIPE 80162 2"x2" Groove 2-5/16" (2.375") 80 1.42 O.D. 61111111 80163 2-1/2"x2-1/2" Groove 2-5/16" 2-1/2(2.875") 80 2.28 80164 3"x3" Groove 2-1/4" (3.500") 80 3.00 80169 2-1/2" x 76,1 mm Groove 2-5/16" 76,1 mm (3.000") 80 2.28 FIGURE 2- FITTING DIMENSIONS (Part 2 of 4) TFPISI5 Page 5 of 6 FITTING PART NOMINAL TAKE-OUT WEIGHT TYPE NUMBER NOMINAL SIZE (TIO) SCHD (lb.) SPRINKLER HEAD ADAPTER 80175E 3/4" x 1/2" NPT 7/16' 80 0.20 80176E 1" x 1/2" NPT 7/16" 80 0.22 [;T/O 80175WL 3/4" x 1/2" NPT 7/16" 40 0.16 80179 lx 3/4" NPT 13/16" 40 0.43 SPRINKLER HEAD ADAPTER 80175W 801 76W 3/4" x 1/2" NPT 1/2" 40 0.19 E; 1" x 1/2 NPT 1/2" 40 0.18 SPRINKLER HEAD ADAPTER (SPIGOT) 80177L 3/4" x 1/2 NPT 1/2" 40 0.16 0.20 80178 1 x 1/2" NPT " 9/16 40 FFT/O 80180 x 3/4" NPT 7/8" 40 0.40 FEMALE ADAPTER 80142 3/4" x 3/4" NPT 13/16" 40 0.41 80145 lx 1"NPT 7/8" 40 0.63 80146 1-1/4" x 1-1/4" NPT 1-1/8" 40 1.03 ;T/O 80147 1-1/2 x 1-1/2" NPT 1-3/8" 80 1.42 80148 x 2" NPT 1-11/16" 80 2.66 MALE ADAPTER 80157 3/4" x 3/4" NPT 1-5/16" 40 0.33 0.56 ;T/C ~ 80158 1' x 1" NPT 1-3/8" 40 XxYxZ X V Z SPRINKLER HEAD 80250 40 0.22 3/4" x 3/4" x 1/2' NPT 9/16" 9/16" 1" ADAPTER TEE Z 80251 xix 1/2" NPT 11/16" 11/16" 1-3/16" 40 0.29 T/O 80249 lx 1" x 1" NPT 15/16" 15/16" 1-9/16" 40 0.73 80256 1-114" x 1" x 1/2" NPT 7/16" 9/16" 1-5/16" 40 0.30 80252 1-1/4" x 1-1/4" x 1/2" NPT 7/16" 7/16" 1-5/16" 40 0.31 80257 1-1/2" x 1-1/4" x 1/2" NPT 1/2" 11/16" 1-7/16" 80 0.43 80254 1-1/2" x 1-1/2" x 1/2" NPT 112" 1/2" 1-7/16" 80 0.46 T/O T/O _________ 80258 2" x 1-1/2" x 1/2" NPT 112" 5/6" 1-11/16" 80 0.56 80253 x 2" x 1/2" NPT 112" 1/2" 1-11/16" 80 0.62 FIGURE 2— FITTING DIMENSIONS (Part 3 of 4) Page 6 of 6 TFPI9I5 FITTING TYPE PART NUMBER NOMINAL SIZE NOMINAL TAKE-OUT (T/O) SCHD WEIGHT (lb.) BACK-TO-BACK TEE XxYxZ X Y,Z x T/O ym~_L 1 80459 lx 1/2" NPTx 1/2" NPT 518" 1-5/16" 40 0.48 80460 1" x 1/2 NPTx 1/2' NPT 5/8" 1-3/16' 40 0.46 Z T/O —T/O BACK-TO-BACK CROSS XxYxZxW X,Y Z,W x —L I/O Z 64 80462 1" x lx 1/2" NPTx 1/2" NPT 5/8" 1-3/16" 40 0.46 3 71 80463 lx lx 1/2" NPTx 1/2" NPT 5/8" 1-5/16" 40 0.47 I/O Y I/O I/O SPRINKLER HEAD XxY X Y ADAPTER 90 ELBOW Y 1/0 80199 3/4" x 1/2" NPT 9/16" 1" 40 0.20 80198 lx 1/2" NPT 3/4" 1-1/4" 40 0.26 X1 80196 lx 314" NPT 1-1/16" 1-7/16" 40 0.26 FIGURE 2— FITTING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 NO. 20 TEE NO. 10 ELBOW ALTERNATE STYLES Victaulic offers a broad line of fittings in sizes through 60/1500mm in a variety of straight and reducing styles. Most standard fittings are cast of durable ductile iron to precise tolerances. Victaulic standard fittings pressure ratings conform to the ratings of Victaulic Style 77 couplings. All fittings are supplied with grooves to permit fast installation without field preparation. The grooved design permits flexibility for easy alignment. These fittings are not intended for use with Victaulic couplings for plain end pipe (refer to Section 1404 for fittings available for plain end applications). Fittings are provided in various materials including ductile iron, steel or segmentally welded steel depending on styles and size. Fittings are painted orange enamel with a galvanized finish available as an option, contact Victaulic for details. Victaulic fittings are designed specifically for use in grooved piping systems. Fittings are provided grooved conforming to standard steel pipe outside diameters. When connecting wafer or lug-type butterfly valves directly to Victaulic fittings with 741 or 743 Vic-Flange® adapters, check disc clearance dimensions with I.D. dimension of fitting. Note: The following Victaulic fittings are VrIS approved: No.10 90° Elbow, No.11 45° Elbow, No.20 Tee and No.60 Cap. Note: The following Victaulic fittings are LPCB approved: No.10 90° Elbow, No.11 45° Elbow, No.12 22112 Elbow, No.13 111/4' Elbow, No.30 45° Lateral, No.30-R Reducing Lateral, No.100 Long Radius Elbow, No.110 Long Radius Elbow, No.20 Tee, No.35 Cross, No.60 Cap, No.25 Reducing Tee, No.33 True Wye, No.50 Concentric Reducer, No.51 Eccentric Reducer and No.29M Tee with Threaded Branch. Advanced Groove System - For 14— 60/350 - 1500 mm piping systems, Victaulic now offers the Advanced Groove System (AGS). Refer to Section 20.05 for AGS fitting details. Stainless Steel - Grooved end fittings are available in Schedule 10 Type 316 stainless steel (Schedule 5, 40 and Type 304 available as an option) in various sizes. Fitting center-to-end dimensions will vary depending upon type and schedule. Refer to Section 17.04 and 17.16 for details. Aluminum - Grooved end fittings are available in aluminum alloy 356 T6, in sizes from 1 - 8/25 - 200mm. Refer to Section 21.03 or contact Victaulic for details. Fabricated Steel - A full range of fabricated segemtnally welded steel or full flow grooved end fittings are available refer to section 07.04. Fabricated Steel with AGS Vic-Rings - A full range of full flow fabricated fittings with Vic-Rings are also available. ADS - ADVANCED GROOVE SYSTEM Extra Heavy EndSeal® 'ES" Fittings - EndSeal fittings are available in 2— 12/50-300 mm for use with "ES" grooved pipe and HP-70ES EndSeal couplings. "ES" fittings are painted black for easy identification. EndSeal (and standard) fittings may be easily internally coated (by others) for severe service requirements. Always specify "ES EndSeal fittings" when ordering. See Section 07.03 for information on EndSeal fittings. Fittings Machined for Rubber or Urethane Lining (MRL) - For severe abrasive services, Victaulic fittings may be rubber or urethane lined (by others). Lining may be inside diameter/end (abrasion resistance) or wrap-around (corrosion and/or abrasion) machined. Refer to Section 25.03 or contact Victaulic for specific details. Note: Fittings are available with a variety of coatings upon request such as hot dip galvanized, epoxy, glass lined and others. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02012 VIcTAULIC COMPANY. ALL RIGHTS RESERVED. REV...R Para -1111, AtauIid CARBON STEEL PIPE - GROOVED FITTINGS 0701 Grooved End Fittings MATERIAL SPECIFICATIONS Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Or: Segmentally welded steel as shown under nipples Nipples: (adapter, swaged & hose) 3/4 - 4/20 - 100mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type F 5-6/125 - 150mm: Carbon steel, Schedule 40, conforming to ASTM A-53, Type E or S, Or. B 8— 12/200 - 300mm: Carbon steel, Schedule 30 or 40, conforming to ASTM A-53, Type E or S, Or. B Flanged Adapter Nipples: (Nipple - see above) Class 125 Flange: Cast iron conforming to ANSI B-16.1 Class 150 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Class 300 Flange: Carbon steel conforming to ANSI B-16.5, raised or flat face Fitting Coatings: Orange enamel Optional: Hot dip galvanized and others. Some fittings supplied electroplated as standard - see product specifications. Flanged Adapter Nipple Coating: None (Unfinished) Optional: Orange enamel, hot dip galvanized and others. www.victaulic.com taulie vicieuuc IS REGISTERED TRADEMARK OF viciuic COMPANY. 02012 VICTAULiC COMPANY. ALL RIGHTS RESERVED. 07.01...2 REV..R CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings The chart expresses the frictional resistance of various Victaulic fittings as equivalent feet of straight pipe. Fittings not listed can be estimated from the data given, for example, a 22112" elbow is approximately one-half the resistance of a 450 elbow. Values of mid-sizes can be interpolated. - - Ijioi'ii.lr.h!flflc. II __ 1 1.315 1.7 0.8 4.2 1.7 25 33.7 2.375 0.5 3.5 ± - 2.5 0.2 1 1.8 i- - 4 1.1 1.3 8.5 0.5 3.5 2 50 60.3 3.000 1.1 4.3 0.8 0.5 2.1 0.3 - 2.6 10.8 1.1 4.3 761 mm 76.1 3.500 1.3 5.0 3.8 0.7 2.6 1 I 1.6 3.3 f 13.0 1.3 5.0 3 80 88.9 1.5 f ....+ 0.8 1 0.5 1 ' 4.0 •, 1.5 108,0 mm 4.250 6.4 3.2 15.3 6.4 108.0 4.500 2.0 6.8 5.0 0 3.4 2.1 4.7 -2.0 - 16.0 6.8 4 . 100 114.3 5.250 2.1 8.1 1.5 I 1.0 I 4.1 .f . 0.6 4.9 f I 20.0 2.1 8] 133.0 mm 133.0 5.500 2.5 8.5 - 1.2 4.2 - 6.2 21.0 2.5 8.5 1397 mm 139.7 5.563 2.6 8.5 - [ 1:3 j 4.2 1 - 6.4 21.0 2.6 8.5 5 175 141.3 6.250 2.6 9.4 .I 1.3 4.9 25.0 6.4 .6 9.6 159.0 mm 9.2 6.500 i t 2.9 9.6 - , 1:5 5.0 - , 7.6 25.0 ,2.9 10.0 165.1 mm 165.1 6.625 2.9 10.0 't - 7.5 1.5 5.0 - 3.0 7.6 25.0 3.0 10.0 6 150 168.3 8.625 3.0 13.0 2.3 9.8 1.5 I 6.5 I 0.9 4.0 7.6 33.0 3.0 13.0 8 200 219.1 10.750 1. 4.0 17.0 - 3.0 12.0 2.0 I 8.3 1.2 5.0 10.1 41.0 4.0 17.0 10 250 273.0 12.750 1 5.2 20.0 3.7 14.5 1 2.5 1 io, £ I 1,5 6.0 12.5 50.0 5.2 20.0 2 300 323.9 14.000 1 6.1 24.58 , 4.4 15.8 3.0 18.55 1.8 , 11.0 - 15.2 70.0 61 23.0 14 350 355.6 16.000 7.5 28.08 , 4.8 18.0 , 5.6 21.08 3.4 13.0 21.3 80.0 7.0 27.0 16 400 406.4 18.000 1 , 8.5 31.05 1 5.5 20.0 6.4, 23.55 14.0 90.0 30.0 18 450 20.000 34.05 22.5 I 25.55 16.0 274 100.0 .. 9.1 33.0 20 800 , 508.0 24.000 i 10.4 42.05 ....................................43 6.9 27.0 , 7.8 29.55 . 4.9 19.0 30.5 120.0 10.1 40.0 24 600 610.0 12'8L 8.2j, 90 j 5.8 36.6 12.2 Fittings available up to 60/1500 mm. Contact Victaulic for details. S contact Victaulic for details. S For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Fitting flow data for 14-247350-600 mm size No. 10 and No. 11 Elbows is based on fittings for Style 07 and 77 couplings. For flow data on AGS fittings (No. W10 and No. Wt I Elbows), refer to submittal 20.05. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s. S= carbon Steel Direct Roll Groove (OGS) SW= carbon Steel Segmentally Welded www.victaulic.com ICTALIC IS REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REVR \htaulid 07.O1_3 FLOW DATA (Frictional Resistance) CARBON STEEL PIPE - GROOVED FITTINGS Grooved End Fittings Reducing Tee CtoE1 r.CtoE.l NO. 291 Threaded Branch NO. 25 Grooved Branch 1jIJI. L j._.ift.f to NO. 25 NO. 291 07.01 a- CtoE-* rCtoE .] LpcL to to NO. 25-SW NO. 291-SW 1.0 0.5 1.3 0.6 1.5 0.? 1.5 0.7 1.7 0.8 25 1.1 2.7 1.2 1.8 0.8 3.0 1.4 3.9 1.8 3.8 1.7 4.2 1.7 3.9 1.8 4.5 2.0 5.7 2.6 6.1 2.8 8.0 3.6 6.5 2.9 6.2 2.8 6.4 2.9 8.0 3.6 7.8 3.5 1 11 I_____ W [_r. - ---. II - ______ 1 34 2.25sw 2.24sw 25 20 57 2.75sw 57 2.75sw 1¼ 1¼ 1 32 32 25 70 2,75sw 70 2.75sw 1½ 1112 '/4 40 40 20 70 L 70 1 2.75sw 2.75 ow - .i 11/4 2.75sw i 2.75 ow 32 70 3.25 70 3.25 2 2 3/4 50 > 50 20 83 83 1 3.25 3.25 25 83 --83. 1¼ 3.25sw 3.25sw 32 83 83 t 114 3.25 3,25sw 40 83 3.75sw 83 3.75sw 2½ 2½ ~ 65 05 20 95 95 1 3.75 3.75sw 5 - 95 1¼ 3.75sw 3.75 ow 32 95 95 1 ½ 3.75 3.75 40 95 95 2 3.75 3.75s 50 95 sw 95 4.25 Sw 3 3 3/4 4.25 x 80 80 >< 20 . 108 108 1 4.25 4.25 25 108 108 1¼ 4.25sw 4.25sw 32 108 108 11/2 4.25 4.25 ow 40 108 108 2 4.25 4.25sw 50 108 108 21/2 4.25 4.25 ow 65 5,005w 108 L...108 5.00sw ~ 100 x 100 20 127 127 1 5.00 5.00 25 127 127 4 4 1 ¼ 5.00sw 5.00sw 9.6 100 100 32 127 127 4.4 1½ 5.00 5.00 10.2 40 127 127 4.6 2 . 5.00 5.00 11.2 50 127 127 5.1 2½ 5.00 5.00 11.4 65 127 127 5.2 + 3 5.00 5.00 11.6 80 127 127 5.3 5 5 1 5.50sw 5.50sw 14.0 125 x 125 x 25__•_ 140 140 6.4 1 ½ 5.50sw 5.505w 14.3 40 140 140 6.5 2 5.50sw 5,50sw 14.5 50 140 140 6.6 t 2½ 5.50 5.50 SW 15.2 65 140 140 6.9 3 5.50 5.50sw 16.6 80 140 140 7.5 4 5.50 1 5.50sw 16.7 100 140 140 7.6 6 6 1 650sw 6.50sw 23.0 150 150 165 J 165 10.4 1½ 6.50 ow 6.50 ow 24.0 40 165 165 10.9 2 6.50 6.50 i 21.6 50 165 165 9.8 71 6.50 6.50 21.4 65 165 165 11.7 4 For AGS fitting information see publication 2005 350 1500 mm + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "s 5= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 07.01_b \4taulicr REVR CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee .CtoE.j rCtoE.l CtoE r t0 E*1 NO. 25 Grooved Branch NO. 291 Threaded Branch to to 1:L3 T j---=:T ¶__i---- NO. 25 NO. 291 NO. 25-SW NO. 291-SW 6 6 3 6.50 6.50 26.5 12 12 1 x 10.00 SW 10.00sw 77.0 150 150 x 80 165 165 12.0 300 300 x25 254 254 34.9 4 6.50 6.50 25.0 2 10.00sw lO,00sw j 80.0 100 165 165 11.3 50 254 254 36.3 5 6.50 6.50 23.2 2½ 10.00 SW lO.00sw 78.0 125 165 165 10.5 65 254 254 35.4 6 ½ 6.50 6.50sw 24.0 3 10.00sw 10.00 SW 82.0 165.1 165.1 80 165 165 10.9 80 254 j 254 + 37.2 4 6.50 6.50sw 25.0 4 10.005w I 10.00sw 80.0 100 165 7.75sw 165 7.75sw 11.3 33.0 100 5 254 254 36.3 1 10.005w 0.00 SW 75.0 8 8 11/2. 200 x 200 x 40 197 197 15.0 ............... 125 254 254 34.0 2 7.75sw 7.75sw 33.5 6 10.00sw 0.00 SW 4 75.0 50 197 197 I 15.2 150 254 254 34.0 2½ 7.75sw 7,75sw 39.0 8 .... 10.00sw 10.00 SW 80.0 65 197 197 j 17.7 200 254 254 36.3 3 775 s 775 s 33.6 10 10.005w 10.00sw 84.0 80 197 197 15.2 250 254 254 38.1 #14 14 x 4 350 x 350 .100 4 100 7.75 7.75 197 97 41.8 19.0 11.00 SW 11,00sw 102.0 279 279 46.3 . . - 5 7.75sw 7.755w 34.0 6 11.00sw 11.00sw 108.2 125 197 197 15.4 150 279 279 49.1 6 7.75 7.75 42.3 8 11.00 11.00 I 112.0 150 197 197 19.2 200 . 279 279 J 50.8 7.75sw 7.75sw 48.0 10 11.00 11.00 120.0 165.1 197 9.00 + 197 9.00 21.8 62.0 300 12 279 - 279 54.4 11.00 11.00 129.1 10 10 1½ 250 250 40 229 229 28.1 300 279 279 58.6 t 9.00 #16 16 4 400 X 400 100 2 50 9.00 SW 29 SW 229 62.0 28.1 130.0 + + 59.0 14 AGS For AGS fitting information see publication 2005 2/2 9.00 SW 1 9.00 SW 62.4 65 329 229 283 , 350-1500mm + Contact Victaulic for details. 3 9.00sw it 9.00 5W 60.0 80 229 229 27.2 Note: All fittings are ductile iron unless otherwise noted with an sw" or "s" 4 9.00 SW 9.00 SW 61.0 100 229 229 27.7 5= Carbon Steel Direct Roll Groove (OGS) 5 9.005w 9.00sw 52.0 SW= Carbon Steel Segmentally Welded 125 229 229 1 23.6 - t IMPORTANT NOTE: 6 9.00sw 1 9.00 SW I 59.0 150 229 229 26.8 No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available 8 900 SW 9.005w 'T 64.7 ' with British Standard threads. For British Standard specify "BSP" clearly 200:. 229 229 29.3 on order. 8 For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. www.victaulic.com -14" A-C -ta -U1 i d VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 6 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REV_R 07.01_11 CARBON STEEL PIPE - GROOVED FITTINGS 07.01 Grooved End Fittings Reducing Tee CtoE1 .CroE.1 NO. 25 Grooved Branch NO. 291 Threaded Branch E11 ._JR to 1_j to JR NO. 25 NO. 291 #20 20 16 17.25 1 288.6 500 500 400 438 - 130.9 18 17.25 297.0 450 438 j 134:7 8 24 24 8 20.00 20.00 340.0 600 600 200 508 508 154.2 10 20.00 20.00 . 343.9 250 508 508 156.0 12 20.00 2000 352.8 300. 508 508 160.0 14 § 20.00 360.0 350 508 , - 163.3 16 20.00 i 378.0 400 508 171.5 18 § 20.00 380.0 450 508 - 172.4 20 20.00 373.0 500 508 169.2 350-1500mm For AGS fitting information, see publication 2005 + Contact Victaulic for details. Note: All fittings are ductile iron unless otherwise noted with an "sw" or "5" S= Carbon Steel Direct Roll Groove (OGS) SW= Carbon Steel Segmentally Welded IMPORTANT NOTE: No. 29T Threaded Outlet Reducing Tees are supplied NPT and are available with British Standard threads. For British Standard specify "BSP" clearly on order. 41 For roll grooved systems, Victaulic offers the Advanced Groove System (AGS). For pricing and availability of cut groove fittings in this size, contact your nearest Victaulic sales office. § Cast fitting available. Contact Victaulic for details. www.victaulic.com \JtauIicr VITAULtC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAtiLiC COMPANY. ALL RIGHTS RESERVED. 07.0112 REV_R INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. UPDATED 08/2012 'Jtauuic 07.01 1449 REV R VIcTAuLIc IS A REGISTERED TRADEMARK OF vIcTAuLIC COMPANY. © 2012 VICTAuLIC COMPANY. ALL RIGHTS RESERVED. 07.01 FireLock EZ® Rigid Coupling STYLE OO9H The FireLock EZ Style 009H coupling is a rigid, installation-ready coupling for fire protection pipe joining. The coupling's unique design eliminates loose parts, insures consistent installation and provides substantial gains in productivity. IMPORTANT FireLock EZ Style 009H couplings are recommended for use ONLY on fire protection systems PATENTED LISTINGS/APPROVALS * The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. Standard Pipe 14 175 1 365 365 365 365 32 1206 1. 12517 j 2517 2517 2517 11/2 175 365 j 365 365 365 40 1206 2517 i, 2517 2517 2517 2 175 365 365 365 365 50 1206 2517 2517 2517 2517 21/2 I N/A 365 365 365 365 65 2517 2517 j 2517 2517 365 I 365 365 76.1 mm j N/A N/A 2517 2517 2517 N/A 365 365 365 365 80 2517 2517 1 2517 2517 108 mm N/A N/A N/A N/A I 365 [ 365 365 365 100 - 2517_j.2517. 2117...... 2517 133 mm N/A ' :. j N/A N/A I I 290 232 365 139.7 mm N/A N/A 1999 1600 2517 I 290 232 365 165.1 mm N/A IN/A + 1999 1600 2517 68 ' N 290 365 232 365 1508 /A 1999 I 2517 1600 I 2517 * Listed/Approved for wet and dry pipe systems (> 40*FI40*C). Please refer to the Victaulic Installation Manual (1-009H_009..009V.pdf) for details concerning when supplemental lubrication is required. ** EN-10219(L) for 76.1mm size; EN-10255(M) Regional availability onlylt FM Approved only. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved www.victaulic.com vicTAuLic IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAIJLIC COMPANY. ALL RIGHTS RESERVED. REV_G \4taulicr 10.61_i I PS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H LISTINGS/APPROVALS * Speciality Pipe 8L1 1 1A - 2 300 300 EZT 1 - 2 300 300 .4 M 300 11/4-2 300 2068 2068 300 300 2068 2068 300 + 300 2068 2068 300 a 2068 2068 FF 1¼-4 2068 MLT 1V4-2 N/A 2068 ELF ST Dl 14-2 300 300 1 300 1¼-4 N/A 2602068 1¼-2 N/A 3 2068 2068 1¼ 2 N/A ¼-4 N/A 8 FLI STF 4-2 1206 1 3 0 068 2068 I 4-2 N/A 2300 ¼- 4 N/A 2068 Ob EL FLTL IF 1-2 2068 8 300 ~00 8 3011 300 2 300 a EZF 300 20682O68 300 2068 2068 1¼-4 3111 t 58 1¼-2 N/A 2068 175 MF WST 2068 2068 300 14-2 12068 12 06 300 2068 sizes. Note: The Specialty Pipe table only applies to imperial sizes, NOT to metric www.victaulic.com \Jt1uIic. VICTAULIC IS REGISTERED TRADEMARK OF VICTAIJLIC COMPANY. © 2012 vICEAULIC COMPANY. ALL RIGHTS RESERVED. 10.612 REV_G IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 10.61 FireLock EZ® Rigid Coupling STYLE 009H STYLE 009H DIMENSIONS _ _ !iH .L4/ jm __JiiTIJLi11 .1 x 1 14 1.660 365 I 790 0.10 2 - 3/8 x 2 2.95 4.77 2.70 4.63 1.93 1 1.4 32 42.4 2517 3514 2.54 - Mb x 2 75 121 69 118 49 ' 0.7 4 f 11/2 1.900 365 1035 0.10 2 - 3/8 x 2 3.19 4.97 2.94 4.79 1.93 1.5 40 48,3 2517 4604 2.54 -M10x2 5 81 126 122 49 0.7 STYLE 009H PRE-ASSEMBLED ' 2 2.37 5 365 1616 1 0.12 2 - 3/8 x 2 3.79 5.53 3.45 5.42 1.93 f 1.9 (PUSH ON CONDITION) 50 60.3 2517 7193 1 3.05 - M10 x 2 1 96 140 88 j 138 , 49 0.9 21/2 2.875 365 2370 0.12 2 - 3/8 x 2½ 4.29 6.09 ' 3.92 5.85 1.93 2.1 Y .-Z- 65 73.0 ..2517 10542 3.05 -Mb0x21/2 109 155j 100 , 149 49 1.0 761 mm 3.000 365 2580 0.12 2 - 3/8 x 2 ½ 4.40 6.31 4.05 I 5.90 1.93 2.1 76.1 2517 11476 3.05 -M10x2½ 112 160 103 150 i 49 1.0 f-- x 3 3.500 365 3512 0.12 2 - 3/8 x2½ 4.91 6.70 4.55 6.46 1.93 2.3 80 88.9 2517 15622 3.05 -M10x2½ , 125 170 116 164 49 11.0 4- 108 mm 4.250 365 5178 0.17 2 - 3/8x2 1/5 5.56 7.61 5.27 7.51 1 2.14 2.8 - 108.0 , 2517 23030 i 4.32 - Mb 0 x2½ , 141 193 134 191 54 1.2 STYLE 009H JOINT ASSEMBLED 4 4.500 365 5805 0.17 2 - 3/8 x2½ 5.95 1 7.82 5.54 7 £ 47 2.14 I 2.9 100 114.3 2517 25822 4.32 -M10x2½4 151 199 141 J 190 55 1.3 133 5.250 365 7900 0.17 2 - 3/8x2 ½ 6.66 9.11 6.36 j 9.01 2.14 4.3 mm 133.0 f 2517 35140 4.33 - Mb 2½ 169 232 162 229 55 1.9 .-. ..................-F ............. 5.500 365 8620 0.17 2 -3/8x2 ½ 6.75 9.29 6.46 I 9.23 2.09 4.6 139.7mm 139.7 I. 2517 0 432 ....-M10x2½ 172 236 164 234 53 2.1 1651 mm 6.500 290 9623 0.17 2 - 5/8 x3¼ 7.84 10.93 7.55 10.85 2.11 5.69 165.1 1999 42805 4.32 -Mb6x3¼ 199 278 192 r 276 54 . 2.6 6 6.625 290 9997 0.17 2 - 5/8x3 ¼ 7.96 11.08 7.67 11.99 2.11 5.92 150 168.3 1999 44469 4.32 I - M16 x3¼ 202 281 195 305 54 2.69 * Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Viclaulic specifications. See page 1 of this document for Listed/Approved ratings on other pipe. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 1112 times the figures shown in the chart on page 1, specific to pipe schedule and size. The allowable pipe separation dimension shown is for system layout purposes only. FireLock EZ couplings are considered rigid connections and will not accommodate expansion or contraction of the piping system. @ Number of bolts required equals number of housing segments. MATERIAL SPECIFICATIONS Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: Orange enamel (North America, Asia Pacific) Red enamel (Europe) Optional Coatings: Hot dipped galvanized Gasket: Grade E' EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. www.victaulic.com jltauIiC VICTAULIC IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. © 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. REtLG 10.613 STYLE 009H GENERAL NOTES NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009H couplings, use FireLock No. 006 end caps containing the "EL" marking on the inside face or No. 60 end caps con- taining the "QV EZ' marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009H couplings. IMPORTANT: Gaskets intended for the Style 009 or Style 009V couplings cannot be used with the Style 009H coupling. There is no interchanging of gaskets or housings between coupling styles. USE OF FLUSHSEAL GASKETS FireLock EZ couplings are supplied with FireLock EL Grade 'E" Type A gaskets. These gaskets FOR DRY PIPE SYSTEMS include an integral pipe stop, that once installed provides the same benefits as a FlushSeal gasket for dry pipe systems. It should be noted that standard FlushSeal gaskets are not compatible and cannot be used with the FireLock EZ couplings. INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. For complete contact information, visit www.victaulic.com 10.61 5731 REV G UPDATED 09/2012 Ac _ta -U1 _id VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 0 2012 VICTAULIC COMPANY. ALL RIGHTS RESERVED. 10.61 Victaulic® Flexible Coupling Style 75 Exaggerated for clarity Approvals/Listings <P1LPCB]® See Victaulic publication 10.01 for details See Victaulic publication 02.06 for portable water approvals if applicable Ac-ta Ui i c 06.05 I & WARNING 1 Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with Victaulic Couplings. Failure to use Victaulic RX roll sets when grooving light-wall/thin-wall stainless steel pipe may cause joint failure, resulting in serious personal injury and/or property damage. NOTICE Victaulic RX grooving rolls must be ordered separately. They are identified by a silver color and the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77, the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes, the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads. When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. 1 ctauIic 2 \4taulic r 06.05 1470 Rev 0 updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Ductile iron conforming to ASTM A-536, grade 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Housing Coating: (specify choice) LI Standard: Orange enamel. LI Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE: Additional gasket styles are available. Contact Victaulic for details. LI Grade "E" EPDM EPDM (Green stripe color code). Temperature range —30°F to +230°FI-34°C to +110°C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +730F/+230C and hot +180°FI-t-82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. LI Grade "1" Nitrile Nitrile (Orange stripe color code). Temperature range 20°F to +180°F/290C to +82°C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150°F/+660C or for hot dry air over +140°F/+600C. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Heat-treated plated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183 3 \ 4tauIic 06.05 1470 Rev 0 Updated 09/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Dimensions Style 75 Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load 2 Separation Centerline3 Bolt/Nut' X V Z Each Pipe inches inches psi lbs. inches Per Cplg. inches/ft. inches inches inches lbs. MM mm kPa N mm Degrees mm/rn (No.) size inches mm mm mm kg 1 1.315 500 680 0-0.06 20-43' 0.57 2- % x 2 2.38 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 48 61 108 45 0.6 1 ¼ 1.660 500 1080 0-0.06 2°-1 ' 0.45 2-3/ox2 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 38 68 117 45 0.6 1 ½ 1.900 500 1420 0-0.06 11-56' 0.40 2-3/ax2 2.91 4.82 1.77 1.5 40 48.3 3450 6320 0-1.6 33 1 74 122 45 1 0.6 2 2.375 500 2215 0-0.06 1°-31' 0.32 2-3/8X2 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 26 87 133 48 0.8 21/3 2.875 500 3245 0-0.06 1°-15' 0.26 x 2- '/a 2 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 22 98 144 48 0.9 76.1 mm 3.000 500 3535 0-0.06 10-12' 0.26 2-3/ax2 4.00 5.90 1.88 1.9 76.1 3450 15730 0-1.6 22 102 150 48 0.9 3 3.500 500 4800 0-0.06 10-2' 0.22 2-½x2~ 4.50 7.00 1.88 2.9 80 88.9 3450 21360 0-1.6 18 114 178 48 1.3 31/2 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 01-54' 2-½x23% 90 101.6 3450 28035 0-1.6 16 127 191 48 1.3 4 4.500 500 7950 0-0. 13 1°-36' 0.34 2-½x23% 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 28 147 204 54 1.9 4.250 450 6380 0-0.13 0.35 5.55 7.79 2.13 3.7 108.0 mm 1°-41' 2-12x70 108.0 3100 28395 0-3.2 29 141 198 54 1.7 41/2 5.000 450 8820 0-0.13 0.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 1°-26' 21 2-5/a X3¼ 156 240 54 2.5 5 5.563 450 10935 0-0.13 10-18' 0.27 2-5/ex3¼ 6.88 10.07 2.13 5.8 125 141.3 3100 48660 0-3.2 23 175 256 54 2.6 5.250 450 9735 0-0.13 0.28 6.55 9.37 2.13 6.0 133.0 mm 1°-21' 2- 16x82.5 133.0 3100 43325 0-3.2 24 166 238 54 2.7 5.500 450 10665 0-0.13 0.28 6.80 9.59 2.13 6.3 139.7 mm 1°-18' 2-5/ox3¼ 139.7 3100 47460 0-3.2 24 173 244 54 2.9 6.000 450 12735 0-0.13 0.21 7.38 10.48 1.88 6.2 152.4 mm 1°-12' 2-5/ax3 ¼ 152.4 3100 56670 0-3.2 18 187 266 48 2.8 6 6.625 450 15525 0-0.13 0.23 8.00 11.07 2.13 7.0 10- 5' 2-%X3'/4 150 168.3 3100 69085 0-3.2 18 203 281 54 3.2 6.250 450 13800 0-0.13 0.24 7.63 10.49 2.13 6.8 159.0 mm 159.0 3100 61405 0-3.2 10-9 ' 20 2-16x82.5 194 266 54 3.1 8 8.625 450 26280 0-0.13 0-50'O' 0.18 2-1/4 x 4¼ 10.34 13.97 2.13 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total, from all internal and external loads, based on standard weight (ANSI) steel pipe, standard roll or cut grooved in accordance with Victaulic specifications. Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled. These figures are maximums; for design and installation purposes these figures should be reduced by: 50% for 34_3 1h"/20 -90 mm; 25% for 4'7100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available (color coded gold) for all coupling sizes upon request. Contact Victaulic for details. WARNING: FOR ONE TIME FIELD TEST ONLY, the Maximum Joint Working Pressure may be increased to 11h times the figures shown. victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Installation Note Reference should always be made to the 1-100 Viclaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications. All products the product you are installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data, and are available in POE format Victaulic reserves the right to change product specifications, designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic° is a registered trademark of Victaulic Company. 06.05 1470 Rev 0 Updated 09/2014 0 2014 Victaulic Company. All rights reserved. victaulic.com 4 J"fCtaUiiC FireLock® Fittings 4tauIicf 10.03 Material Specifications: Fitting: Ductile iron conforming to ASTM A-536, grade 65-45-12. - Fitting Coating: U Orange enamel 0 Red enamel in Europe, Middle East, Africa, and India 0 Optional: Hot dipped galvanized Approvals/Listings: c®us BI Q-tP USTED Product Description: FireLock® products comprise a unique system specifically designed for fire protection services. FireLock full-flow elbows and tees feature CAD- developed, hydrodynamic design, affording a shorter center-to-end dimension than standard fittings. A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic couplings that have been Listed or Approved for Fire Protection Services. Use of other couplings or flange adapters may result in bolt pad interference. Refer to the appropriate listing agency or approval body for pressure ratings. Pressure ratings vary by agency. Job/Owner System No. Location Contractor Submitted By Date Engineer Spec Section Paragraph Approved Date victaulic.com I FireLock® Fittings I Publication 10.03 10.03 1539 Rev M Updated 12/2014 © 2014 victaulic Company. All rights reserved. '.,4tauiicr 1 victaulic.com I FireLock® Fittings I Publication 10.03 Dimensions: C to to E NO. 001 C toE to to E Ib -IL NO. 003 NO. 002 No. 006 No. 001 No. 003 No. 002 No. 006 900 Elbow 45° Elbow Straight Tee Cap Approx. Approx. Approx. Approx. Actual Nominal Outside Weight Weight Weight Weight Size Diameter C to E Each C to E Each C to E Each C to E Each inches inches inches Lbs. inches Lbs. inches Lbs. inches Lbs. MM mm mm kg mm kg mm kg mm kg 11/4 1.660 0.82 0.3 32 42.4 - - - - - 21 0.1 1 ½ 1.900 - - - - - 0.82 0.4 40 48.3 - - - - - - 21 0.2 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3.000 3.00 3.30 2.25 2.4 3.00 3.8 76.1 76 1.5 57 1.1 76.2 1.7 - - 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108mm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3,9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 139.7mm 5.500 4.88 12.4 3.25 8.2 4.88 15.4 139.7 124.0 5.6 82.6 3.7 124.0 6.9 - 159mm 6.250 5.50 12.6 3.50 9.2 5.50 17.9 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 165.1 mm 6.500 5.43 17.6 3.50 11.4 5.50 22.0 165.1 139.7 7.9 88.9 5.2 139.7 9.9 . - 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 10.03 1539 Rev M Updated 12/2014 0 2014 Victaulic Company. All rights reserved. viCtaulic.com 2 \,4'tauIiC° A 1 SHIPPING BAR GROOVED END - - ®us C FOR FIRE 900 L.R. SPRINKLER ELBOW SYSTEMS HOSE & BRAID B MATERIALS OF - CONSTRUCTION END FITTINGS - CARBON STEEL - SCH 40/STD WI HOSE & BRAID - STAINLESS STEEL -300 SERIES 1800 90° ELBOW - CARBON STEEL - SCH 40/STD WI RETURN —N 180° RETURN - CARBON STEEL - SCH 40/STD WI AIR RELEASE OR DRAIN PLUG SUPPORT BRACKET (2 AND LARGER) NOTE: METRALOOPS 2" AND LARGER INSTALLED IN ANY ORIENTATION OTHER THAN HANGING DOWN MUSTHAVE THE 1800 RETURN SUPPORTED. (SEE INSTALLATION INSTRUCTIONS.) CONTACT FACTORY FOR ADDITIONAL SIZES AND MOVEMENTS. ALL DIMENSIONS IN INCHES. QTY SIZE MODEL MOVEMENT A B PSI WI (LBS) PROJECT INFO 1" (25mm) MLUG80100 ±4" 15' 300 8 1.25' (32mm) MLUG80125 ±4" 15.75' 300 10 1.5' (40mm) MLUG80150 ±4" 17.5" 23" 300 15 2' (50mm) MLUG80200 ±4" 20" 25" 300 18 2.5" (65mm) MLUG80250 ±4" 21.5" 28" 300 29 (80mm) MLUG80300 ±4" 24' 30" 300 43 (100mm) MLUG80400 ±4" 3C" 35" 175 60 (125mm) MLUG80500 ±4" 36" 40' 175 99 (150mm) MLUG80600 ±4" 42" 46" 175 150 8" (200mm) MLUG80800 ±4" 56" 58' 175 286 10" (250mm) MLUG81000 ±4" 68" 64" 175 450 12" (300mm) MLUG81200 ±4" 80" 73" 175 665 SUITABLE FOR USE IN DRY PIPE SYSTEMS FOR TEMPERATURES TO -40 °F. 3 I ia & 12" ADDED 11/20/2017 REV. 2 SIZES ADDED DATE 1/4/2017 OW 2323W. HUBBARD ST. 1 Metrailiex Lfor pipes in motion CHICAGO, IL 60612 TEL: 312-738-3800 WWW.METRAFIRE.COM CUSTOMER: METRAFLEX FIRELOOPTM GROOVED ENDS, ±4" MOVEMENT PROJECT: I DRAWN BY: DKISH 'DATE: 1/4/2014 APPROVED: ZB I DATE: 1/4/2014 ENGINEER:______________________________________ SCALE: NUMBER: NTS 1111WIIG MLUG8-3 02017 The Metroflex Co. Mp"Ong Products Quality Service - Comniitincnt - Delivered_ - Malleable Threaded Fittings ALL MALLEABLE THREADED FITTINGS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 197- Standard Spec for Cupola Malleable Iron ASTM A 153- Standard Spec for Zinc Coating (Hot Dip) on Iron and Steel ANSI B 16.3- Malleable Iron Threaded Fittings Classes 150 ANSI/ASME BI.20.1- Pipe Threads, General Purpose (Inch) NPT Ductile Iron Threaded Fittings ALL DUCTILE IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 536- Grade 65-45-12 ASME B 16.3- Ductile Iron Threaded Fittings Classes 150 ANSI/ASME B1.20.1- Pipe Threads, General Purpose (Inch) NPT Cast IronThreaded Fittings ALL CAST IRONS MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 128- Class B Standard Spec for Cupola Cast Iron ANSI B 16.4- Cast Iron Threaded Fitting Classes 125 ANSI/ASME BI.20.1- Pipe Threads, General Purpose (Inch) NPT Steel Pipe Nipples ALL STEEL PIPE NIPPLES MANUFACTURED FOR AND BY SIGMA PIPING PRODUCTS CONFORM TO, COMPLY WITH, AND ARE MANUFACTURED TO THE FOLLOWING STANDARDS: ASTM A 53- Standard Spec for Pipe, Steel, Black and Hot-Dipped, Zinc Coated, Welded and Seamed ANSI/ASME BI.20.1- Pipe Threads, General Purpose (Inch) NPT www.sigmaco.com JI1[i1IIs O Dimensions: ANSI B16.3 CLASS 150 [1 Coating: Black- none; Galvanized- Hot Dip per ASTMAl53 D Material: Malleable iron per ASTM Al 97 []Threads: Pipe Threads, General Purpose ASME B1.20.1 Description 1 1 r19OM1L ITEMIOflEi JED1MEN1IOiN1 Malleable Threaded 90 LEJI BLAcK II AI.V II A FB1LWEMIJ - A 3/8" 1M9080303 1M90B0303G 0.95 0.95 0.17 1/2" 1M90B0404 1M90B0404G 1.12 1.12 0.30 3/4 1M90B0505 1M9080505G 131 131 045 1" 1M90B0606 1M90B0606G 1.50 1.50 0.73 1 1/4" 1M90B0707 1M90B0707G 1.75 1.75 0.97 / 1 1/2" 1M90130808 1M90B0808G 1.94 1.94 1.30 /B 2" 1M90B0909 1M90B0909G 2.25 2.25 2.06 f - 2 1/2" 1M9013I0I0 1M90BIO1OG 2.70 2.70 3.55 3" 1M90131111 1111111 3.08 3.08 5.46 - LISTED ' 1M90B1212 1M90B1212G 3.79 3.79 8.95 Description I Malleable Threaded 45 TNOM1F ITEMQflE 1EDIMEN1uN1 iTEM I S1ZJ1 BLACK ii GALV 11 A II I 3/8" 1M45B0303 1M45B0303G 0.80 0.80 0.16 A 1/2" 1M45B0404 1M4560404G 0.88 0.88 0.22 3/4 1 M45B0505 I M45B0505G 0.98 098 0.37 I" 1M45B0606 1M45B0606G 1.12 1.12 0.54 1 1/4 1M45B0707 1M45B0707G 1.29 129 0.86 11/2" 1 M45B0808 1 M45B0808G 1.43 1.43 1.13 \ 2" 1M451130909 1M45B0909G 1.68 1.68 1.79 B 2 1/2" 1M4511i 1M45B101OG 1.95 1.95 2.78 Ui. " 1M45B1111 1M45B1111G 2.17 2.17 4.48 LISTED " 1M45B1212 1M45B1212G 2.61 2.61 7.40 Description ________________________________________ ITEMICCDE 1LDIMENS1NII[ ITEM1 SIZE I BLACK1[ALV 1r 1EB1LwEIGHT I Malleable Threed9O 3/8" 1M90S0303 1M90S0303G 0.80 1.00 0.17 -I11ff1T1 1/2" 1M90S0404 1M90S0404G 0.88 1.13 0.24 3/4 1M90S0505 1M90S0505G 1.00 1.31 0.41 1M90S0606 1M90S0606G 1.23 1.44 0.62 / 1 11/4" 1M90S0707 1M90S0707G 1.31 H 1.69 1.09 B I U1 11/2" 1M90S0808 1M90S0808G 1.44 1.88 1.44 __ I 2" 1M90S0909 1M90S0909G 1.69 2.25 2.85 -A--] LISTED Description 1 1 I ITEMCQDE I ITEM Hex Nut SIZE I BLAC1( 1ELV I WEIGHT 1/2" 1MLN04 1MLN04G 0.12 3/4" IMLN05 1MLN05G 0.22 / I 0 Malleable 1" - 1MLN06 IMLN06G 0.38 ) 1 1 1/4" IMLN07 IMLN07G 0.58 o 1 1/2" LISTED www.sigmaco.com Malleable Threaded Description 1 1 L iTEMflE iEIMENS1flN1 TEM BLAK1I GALV IF1EB1WEIGid Malleable Reducing NOM SIZE Bend 1/2" X 3/8" 1M90R0403 1M90R0403G 1.00 1.06 0.22 B 3/4" X 1/2" 1M90R0504 1M90R0504G 1.19 1.25 0.38 1" X 1/2" 1M90R0604 1M90R0604G 1.25 1.38 0.46 X 3/4" 1M90R0605 1M90R0605G 1.38 1.44 0.56 / - 1 1/4" X 1/2" 1M90R0704 1M90R0704G 1.38 1.56 0.61 / A 1 1/4" X 3/4" 1M90R0705 1M90R0705G 1.44 1.63 0.71 11/4" X 1" 1 M90R0706 1 M90R0706G 1.44 1.66 1.15 f 11/2" X 1/2" 1M90R0804 1M90R0804G 1.41 1.66 1.15 11/2" X 3/4" 1 M90R0805 I M90R0805G 1.50 1.75 1.08 1 112"X 1" 1M90R0806 1M90R0806G 1.63 1.81 1.02 Ui 11/2" X 11/4" 1M90R0807 1M90R0807G 1.81 1.88 1.17 LISTED 2" X 1/2" 1M90R0904 1M90R0904G 1.49 1.88 1.30 X 3/4" 1 M90R0905 1 M90R0905G 1.63 2.00 1.30 2" X 1" 1M90R0906 1M90R0906G 1.75 2.00 1.35 2" X 1 1/4" 1M90R0907 1M90R0907G 1.88 2.13 1.53 2" X 1 1/2" 1M90R0908 1M90R0908G 2.00 2.13 1.75 Description I I Malleable Threaded Tee LISTED NUM7E ITEMQDE ]UIM. 1F7MMW7 SIZE 1L1CK II GALV II A II WEIGI-I 1/4" 1MT020202 1M1020202G 0.81 0.15 3/8" 1 M1030303 1 M1030303G 0.94 0.23 1/2 1MT040404 1M1040404G 113 041 3/4" 1M1050505 1MT050505G 1.31 0.60 I" 1MT060606 1M1060606G 1.50 0.90 11/4" 1M1070707 1MT070707G 1.75 1.31 1 1/2" 1M1080808 1MT080808G 1.94 1.73 2" 1MT090909 1MT090909G 2.25 2.52 2 1/2" 1MT101010 1MT101010G 2.69 4.90 1MT111111 1MT111111G 3.06 7.13 1MT121212 1MT121212G 3.81 11.32 Description L 1 FlqUM-1 L1TEMCQJYE IEDIM.1 t BLAcK I AiVi IL A1 wiGHil Malleable Threaded I SIZE iCross A--A- 1/2" IMX04 IMX04G 1.12 0.42 3/4" 1MX05 1MX05G 1.13 0.69 I 1MX06 IMXO6G 1.50 1.12 I 11/4" 1 MX07 1 MX07G 1.75 1.44 11/2" 1 MX08 I MXO8G 1.94 1.98 IMX09 IMX09G 2.25 3.30 UL 2 1/2" 1MX10 IMXIOG 2.70 5.90 A 1MX11 IMXIIG 3.08 13.50 I LISTED www.sigmaco.com Malleable Reducing Tee rd- Description [ I Malleable Cap Malleable Threaded Fit Description 1 1 NOM 1TEMQDE 1LD1MEN- 1flTEM rsLAgIrGALv]I A1LffIrcil 1/2" X 1/2"X 3/8" 1MT040403 1M1040403G 1.06 1.06 1.06 0.30 3/4" X 1/2" X 1/2" 1MT050404 1M1050404G 1.08 1.08 1.09 0.38 3/4" X 1/2" X 3/4" 1MT050405 1MT050405G 1.11 1.11 1.13 0.46 3/4" X 3/4" X 1/2" 1MT050504 1MT050504G 1.19 1.19 1.25 0.47 1" X 1/2" X 1/2" 1MT060404 1MT060404G 1.21 1.21 1.30 0.58 1" X 3/4" X 1/2" 1MT060504 1MT060504G 1.22 1.22 1.32 0.59 1" X 3/4" X 3/4' 1MT060505 1MT060505G 1.23 1.23 1.33 1.59 1" X 1" X 1/2" 1MT060604 1MT060604G 1.25 1.25 1.38 0.70 1" X 1" X 3/4" 1MT060605 1M1060605G 1.38 1.38 1.44 0.82 11/4" X 1" X 1" 1MT070606 1MT070606G 1.56 1.56 1.69 1.10 1 1/4" X 1 1/4" X 1/2" 1MT070704 1MT070704G 1.38 1.38 1.56 0.98 1 1/4" X 1 1/4" X 3/4" 1MT070705 1MT070705G 1.40 1.40 1.60 0.94 11/4 X 11/4 X 1 1MT070706 1MT070706G 1.56 1.56 1.69 1.20 11/2" X 11/4" X 1" 1MT080706 1MT080706G 1.63 1.63 1.81 1.30 UL 1 1/2 X 1 1/2 X 1/2 1MT080804 1MT080804G 1.44 1.44 1.69 119 ' 11/2" X 11/2" X 3/4" 1MT080805 1MT080805G 1.50 1.50 1.75 1.30 LISTED 1 1/2 X 1 1/2 X I 1MT080806 1M1080806G 1.63 1.63 1.81 1.45 11/2" X 11/2" X 11/4" 1MT080807 1MT080807G 1.81 1.81 1.88 1.52 2 X 2 X 1/2 1 MT090904 I MT090904G 1.50 1.50 1.88 1.65 2" X 2" X 3/4" 1 MT090905 I MT090905G 1.63 1.63 2.00 1.87 2" X 2" X 1" 1MT0909061MT090906G 1.75 1.75 2.00 1.76 2" X 2" X 1 1/4" 1MT090907 1MT090907G 1.88 1.88 2.13 2.35 2" X 2" X 1 1/2" 1MT090908L1MT090908G 2.00 2.00 2.19 2.55 2 1/2" X 2 1/2" X 1" IMTI01006 IMT101006G 1.88 1.88 2.38 2.85 2 1/2" X 2 1/2" X 1 1/4" 1MT101007 L1MT101007G 2.06 2.06 2.44 3.36 21/2X21/2X11/2 1MT101008 IMT101008G 2.19 2.19 2.50 3.46 2 1/2" X 2 1/2" X 2" 1MT101009 1IMT101009G. 2.38 2.38 2.62 3.65 3" X 3" X 1/2" 1MT111104 1MT111104G 1.76 1.76 2.52 4.03 3" X 3" X 3/4" 1MT111105 1MT11II05G 1.88 1.88 1.63 4.03 3"X 3"X 1" 1MTII1I06 1MT11I106G 2.00 2.00 2.62 4.13 3"X3"X 11/4" 1MT111107 1MT111107G 2.19 2.19 2.75 4.50 3" X 3" X 11/2" 1MT111I08 1MT111I08G 2.31 2.31 2.81 5.18 3" X 3"X 2" 1MTI11109 1MTII11096 2.50 2.50 2.88 5.70 3" X 3" X 11/2" 1MT111110 1MT1111I0G 2.57 2.57 2.89 5.00 4" X 4" X 11/4" 1MT121207 1MT121207G 2.39 2.39 3.26 7.47 4" X 4" X 11/2" 1MT121208 1MT111208G 2.51 2.51 3.32 7.47 4" X 4"X 2" 1MT121209 '1MT121209G 2.75 2.75 3.44 8.39 4" X 4" X 2 1/2" 1MT121210 1M1121210G 2.75 2.75 3.44 7.70 4 X 4 X 3 1MT121211 r1MT121211G 331 331 363 893 [NU1W]L JIEMICODE i ITEM I SIZE II LACK II GALV I LWEWIHIJ 1/2" . 1MK04 1MKO4G 0.14 3/4" IMKO5 1MKO5G 0.21 IMK06 IMK06G 0.37 1 1/4" 1MK07 IMK07G 0.58 11/2 1 MK08 1 MK08G 0.74 1 MKO9 I MK09G 0.94 21/2" IMKIO 1MK10G 19 3" 1MK11 1MK11G 2.79 UL 4" 1MKI2 IMKI2G 3.66 LISTED www.sigmaco.com LISTED Description I Malleable Floor Flange B A LISTED www.sigmaco.com Malleable Threaded Description I - Malleable Coupling FRDM-lr- IIEMITCO iEDIMl ENFI LqIZE LBL ALV1EA1 wEjGTJ 3i8" 1MCP0303 1MCP0303G 1.18 0.13 1/2" IMCP0404 IMCP0404G 131 0.20 3/4" 1MCP0505 IMCPO5O5G 1.50 0.30 1" 1 MCP0606 1MCP0606G 1.69 0.48 1 1/4 1 MCP0707 1 MCPO7O7G 1 93 0.75 11/2" 1MCP0808 1MCP0808G 2.13 1.00 2 1 MCP0909 1 MCPO9O9G 2.50 1.45 2 1/2" iMCP1010 1MCP1010G 2.88 2.40 3 1MCP1111 1MCP1111G 319 330 4" 1MCP1212 IMCP1212G 3.69 5.72 'NOM SIZE L I ETITEM ELACIc1 1EIMJrET E IIrx1 M LWIIIIJ 1/2" X 3/8" 1MCRO403 IMCR0403G 0:17 0.17 3/4" X 1/2" IMCRO504 IMCRO5O4G 0.27 0.27 1"X 1/2" 1 1MCR0604 1MCR0604G 4 0.39 0.39 I" X 3/4" 1MCR0605 1MCR0605G 0.43 0.43 1 1/4"X 1/2" IMCR0704 IMCR0704G 0.61 0.61 1 1/4" X 3/4" IMCR0705 IMCR0705G 0.64 0.64 -V I/4- X 1 1MCR0706 1MCR0706G 068 0.68 1 1/2"X 1/2" IMCR0804 IMCRO804G 0.78 0.78 1 1/2 X 3/4 IMCR0805 1MCRO8O5G 088 .0 .88 11/2" X 1" 1 MCRO806 I MCR0806G 0.88 0.88 1 1/2--1-11/4" IMCR0807 IMCR0807G 090 0.90 2"X 1/2" 1MCRO904 IMCRO904G 1.15 1.15 2" X 3/4" 1 MCRO905 1 MCRO9O5G 1.34 1.34 2"X 1" IMCRO906 iMCR0906G 1.40 1.40 2"X 11/4" IMCRO907 :1MCR0907G l• 1.5.3 2"X 11/2" 1MCR0908 IMCRO908G 1.55 1.55 1.2-112" X 1 1/4" 1MCR1007 LIMCR1007G 2.09 2.09 2 1/2" X 1 1/2" 1MCR1 008 IMCRIO08G 2.09 2.09 21/2 X2 1MCRI009 IMCRI009G 251 251 3"X 1 1/4" IMCRI107 IMCR1107G - 2.99 2.99 3"X 11/2" 1MCR1108 11McR1108G 3.30 :1 3.30 3" X 2" IMCRII09 IMCR1109G - 3.25 3.25 3"X2 1/2" 1MCR11I0 1MCR1110G 3.29 3.29 4" X 1 1/2" IMCR1208 1MCR120BG 4.90 4.90 4"k 2 1MCR1209 1MCR1209G 510 510 4"X 2 1/2" IMCRI210 IMCR12IOG 6.55 6.55 4"X3" 1MCR12I1 IMCR1211G 4.04 : 4.04 ENO'Ml L_aEMiCDIDJE '[MEt1$IaNJ iNELGI-iI 1/2" IMFF04 IMFF04G 3.50 2.50 0.56 3/4" IMFF05 IMFF05G 3.50 2.50 0.60 11, 1MFF06 1MFF06G 400 30 084 1 1/4" 1MFF07 1MFF07G 4.00 3.00 0.90 1 1/2" IMFF08 1 IMFF08G 4.50 3.50 1.20 2" IMFF09 1MFF09G 5.50 4.25 2.03 A UL LISTED Description I Malleable Reducing Coupling Malleable Threaded Description I I Malleable Plug Li'flA 1fli*1PI.I •iItt*, IlLW 3/8" IMPLG03 IMPLGO3G 0.06 1!2" 1MPLG04 1MPLG04G 0.10 3/4" 1MPLGO5 1MPLG05G 0.17 1MPLGO6 1MPLG06G 0.28 1 1/4" 1MPLGO7 1MPLG07G 0.44 1 1/2" 1MPLG08 1MPLG08G 0.62 IMPLGO9 IMPLG09G 0.91 UL 2 1/2" IMPLGIO IMPLGIOG 1.05 LISTED 3" IMPLGII 1MPLG11G 1.70 4" 1MPLG12 1MPLGI2G 3.00 Description I I Malleable Bushings NOM SIZE L ITEMflDIEI 1[ ITEM [BLACK II GALY JLWEJGHIJ 1/2" X 1/4" 1MBSH0402 IMBSH0402G 0.06 1/2" X 3/8" IMBSH0403 1MBSH0403G 0.05 "X 1/2" IMBSH0504 IMBSH0504G 0.11 1" X 1/2" IMBSH0604 1MBSH0604G 0.21 1" X 3/4" 1MBSH0605 IMBSH0605G 0.17 1 1/4" X 1/2" 1MBSH0704 IMBSH0704G 0.34 1 1/4 X 3/4 IMBSH0705 IMBSH0705G 0.31 I 1/4"X1" IMBSH0706 1MBSH0706G 0.26 1 1/2"-.X 1/2 IMBSH0804 IMBSH0804G 048 1 1/2" X 3/4" IMBSH0805 1MBSH0805G 0.48 1 1/2" X 1" IMBSH0806 1MBSH0806G 0.43 1 1/2" X 1 1/4" 1MBSH0807 1MBSH0807G 0.30 2" X 1/2" IMBSH0904 1MBSH0904G 0.65 2" X 3/4" IMBSH0905 1MBSH0905G 0.83 2" X 1" 1MBSH0906 IMBSH0906G 0.78 2"X 1 1/4" IMBSH0907 1MBSH0907G 0.73 2" X 1 1/2" IMBSH0908 1MBSH0908G 0.60 2 1/2"X 11/4" IMBSH1007 1MBSHI007G 1.30 2 1/2" X 1 1/2" 1MBSH1008 IMBSHIOO8G 1.20 2 1/2" X 2" 1MBSH1009 1MBSH1009G 0.90 3" X 11/4" 1MBSHII07 1MBSH1107G 2.50 3"X 1 1/2" IMBSH1108 1MBSH1108G 2.30 3" X 2" 1MBSH1109 1MBSH1109G 2.00 3"X21/2" 1MBSH1110 1MBSH1110G 1.60 4"X I 1/4" IMBSH1207 IMBSH1207G 3.20 4"X 1 1/2" 1MBSH1208 IMBSH1208G 3.30 4"X2" 1MBSHI209 1MBSH1209G 3.10 4" X 2 1/2" 1MBSHI2I0 IMBSHI2IOG 3.80 4"X3" IMBSHI2II IMBSHI211G 3.00 www.sigmaco.com A Malleable Threaded Description I FNUIW-1 I ITEM MM IIiDIMiI ITEM Malleable Union BLACK SIZE JI H GALV IF A II.WEIGHT 1/4" IMUN02 IMUN02G 1.81 0.45 A 3/8" 1MUN03 1MUN03G 1.81 0.42 1/2" 1MUN04 1MUN04G 1.94 0.44 _____ 3/4" IMUN05 1MUN05G 2.06 0.60 1MUN06 1MUN06G 2.44 0.91 1 1/4" 1MUN07 IMUN07G 2.63 1.45 1 1/2" IMUN08 IMUN08G 2.75 1.69 1MUN09 IMUN09G 2.94 2.46 IMUNlI 1MUN11G 3.63 4.95 LISTED 4" 1MUN12 1MUN12G 3.75 8.75 Description I [NUM I F7TM97 I SIZE ][BLACKJ[ GALV ]l A lLwE1GH1r 1/4" 1MUNBS02 1MUNBS02G 1.81 0.45 3/8" IMUNBS03 1MUNBS03G 1.81 0.42 1/2 1MUNBS04 IMUNBS04G 1.94 044 3/4" IMUNBS05 1MUNBS05G 2.06 0.60 I IMUNBS06 1MUNBS06G 244 091 1 1/4" IMUNBS07 IMUNBS07G 2.63 1.45 Ui 1 1/2" 2" IMUNBS08 1MUNBS09 IMUNBSOBG IMUNBS09G 2.75 2.94 1.69 2.46 " 1MUNBS11 1MUNBS11G 3.63 4.95 LISTED 4" 1MUNBS12 IMUNBSI2G 3.75 8.75 Description F [1(0M11 ITEM CODEI WD1M1I ITEM Malleable Extension I. SIZE ]LBiAi][ GAUl 1[ A 1LWEIGHT A 1/2" 1MEXO4 1MEXO4G 1.95 7.32 LISTED www.sigmaco.com Malleable Union wi Brass Seat 1101 Oil 1 AN MIws 0 O Notice: D.I. Fittings have higher tensile strength then that of steel pipe, over tightening can cause damage to pipe threads which may cause leakage. D.I. Fitting should be tightened three turns beyound hand tighten, no more than four turns. O D.I. Threaded fittings are UL, cUL listed and Factory Mutual approved for 500psi servce. D. 1. Per ASTM A 536 grade 65-45- 12. Dimensions conform to ANSI 1316.3 Class 150. Threads are NPT per ANSI/ASME 131.20.1 Description EII_ I D. 1. 90 Degreed Elbow _ jus F NOM SIZE IITtO1E1IIflIMENSIDNi ITEM I 1.[BLACK II A ji B iWElfiHil 1D90B0606 1.50 1.50 0.62 11/4" 1D90B0707 1.75 1.75 0.90 1 1/2 1D90B0808 1.94 1.94 1.20 1090130909 2.25 2.25 1.85 Description F D. Straight Tee Al A BF [Ul C J H NOM SIZE FITh D1Efl1MNSIN1f ITEM I L BLACK 1[AII B 1WEIGHII 1DT060606 1.50 1.50 0.85 1 1/4" 1D1070707 1.75 1.75 1.22 1 1/2" 1D1080808 1.94 14 1.55 10T090909 2.25 2.25 2.45 Description [ D.I. Coupling AQ J C (E) as UMID [ 7flTEMCQpIFTflM1TITEM] i NOM SIZE j BLACK IAWEIwi IDCP0606 1.50 0.85 11/4" 1DCP0707 1.75 1.22 1 1/2" IDCP0808 1.94 1.55 IDCP0909 2.25 2.45 Description I D. Red. 90 Deg. Ell bow USTED UTEMDDEWDJMENS1N1flTEM I NOM SIZE I BLACK II A ][B]ALEIGJf 1 X1/2" 1D90R0604 1.26 1.36 0.44 I X 3/4" 11)90R0605 1.37 1.45 0.52 11/4 X 1/2" 1090R0704 1.34 1.53 0.64 1 1/4 X 3/4" 1090R0705 1.45 1.62 0.72 1 1/4" X 1" 1090R0706 1.58 1.67 0.75 1 1/2" X 1" 1D90R0806 1.65 1.80 0.92 11/2" X 11/4" 1090R0807 1:82 1.88 1.08 2" X 1/2" 1D90R0904 1.49 1.88 1.08 2" X 3/4" ' 1D90R0905 1.60 1.97 1.24 2"X 1" 1D90R0906 1.73 2.02 1.40 2" Xl 1/4" 1D90R0907 1.90 2.10 1.52 2" X 1 1/2" 1D90R0908 2.02 2.16 1.65 Description I _i D. 1. Reducing Coupling IlTEM CIEID1 NOM SIZE MJF 1TEM1 CK I A INEIGHJ1 c®u F 1 X 1/2" 1DCR0604 1 1.69 0.39 USM I X 3/4" IDCR0605 1.69 0.53 Description I I D. 1. 45 Degreed Elbow USM I flEMtDEI1flIMENSJtJJI ITEM 1 I NOM SIZE]EBLACIC II A IrB1wEjGHi1 111)451130606 1.12 1.12 0.46 1 1/4" 111)45130707 1.29 1.29 0.73 1 1/2" 1D451130808 1.43 1.43 0.92 1D45B0909 1.68 1.68 1.50 www.sigmaco.com Ductile Iron Threaded Description I D. 1. Bushing [ B : A kA ______ us OUTSIDE HEAD INSIDE HEAD 'N M ZIIIIT CODE1IDtMENSJNI1 FTY~L rwl EJET1EJ I X112" 1DBUS0604 0.75 0.25 1.42 OUT 0.22 I X 3/4" IDBUS0605 0.75 0.25 1.42 OUT 0.17 11/4 Xl IDBUS0706 080H028 176 OUT 1.28 1 1/2" X I" 1DBUS0806 0.83 0.31 2.00 OUT 0.44 1 112"X 11/4. IDBUS0807 0.83 0.31 2.00 OUT 0.30 2"X 1" 1DBUS0906 0.88 0.41 1.95 IN 0.66 2 Xl 1/4 1DBUS0907 088 034 248 OUT 072 2" X 1 1/2" 1DBUS0908 0.88 0.34 2.48 OUT 0.61 Description I D. 1. Cross -B--B- 7 c T1L - us L (4A L I1ThM coD'EIEIDIMENSIDNIrITEM 1NOM SIZE EBLACK ii A IEB1hNEJGH 10X0606 1.50 1.50 0.98 11/4" 1DX0707 1.75 1.75 1.50 1 1/2" 1DX0808 1.94 1.94 - 1.90 10X0909 2.25 2.25 2.95 11/4" X 1" 10X0706 1.58 1.67 1.27 11/2" X 1" 1 DX0806 1.65 1.80 1.45 2"X 1" 1DX0906 1.73 2.02 2.10 Description 1 D. 1. Cap a-, c YL USTD RTEMLDIM. I ITEM NOM SIZE BLACK 11 A IWEIGH 1DK06 1.16 0.32 1 1/4" 1DK07 1.28 0.43 1 1/2" 1DK08 1.33 0.60 IDK09 1.45 0.91 www.sigmaco.com Description L D.I. Reducing Tee ME 1=1 USHO IITEMCOUE1 EDtMENS1flN I11TEM1 NOM SIZE BLACK1I A IC Wi [1NE,GH11 1"x 1"x 1/2" 1DT060604 1.26 1.26 1.36 0.64 1" x 1" x 3/4" 1DT060605 1.37 1.37 1.45 0.73 1 x 1/2 x 1 10T060406 1.50 1.36 1.50 0.71 1" x 3/4" xl" 1DT060506 1.50 1.45 1.50 0.76 1" x 1" x 1 1/4" 10T060607 1.67 1.67 1.58 0.98 1"x1"x1 1/2" 101060608 1.80 1.80 1.65 1.16 1 1/4" x 1" x 1/2" 1D1070604 1.34 1.26 1.53 0.82 1 1/4" x lx 3/4" 1DT070605 1.45 1.37 1.62 0.90 1 1/4' x 1' x1" 10t070606 1.58 1.50 1.67 1.00 1 1/4" x 1" x 1 1/4" 101070607 1.75 1.67 1.75 1.08 11/4" x 1" x 1 1/2" 101070608 1.88 1.88 1.82 1.42 1 1/4" x 1 1/4" x 1/2" 101070704 1.34 1.34 1.53 0.86 1 1/4" x 1 1/4" x 3/4" 10T070705 1.45 1.45 1.62 0.92 11/4" x 11/4" x 1" 10T070706 1.58 1.58 1.67 0.95 11/4" x 1/4" x 1" 10T070708 1.88 1.88 1.82 1.45 11/4" x 1/4' x 2" 10T070709 2.10 2.10 1.90 1.75 1 1/2" x 1" x 1/2" 101080604 1.41 1.34 1.66 0.95 11/2" xl" x 3/4" 101080605 1.52 1.37 1.75 1.14 1 1/2" xl"x 1" 101080606 1.65 1.50 1.80 1.17 11/2"xl"x11/4" 101080607 1.82 1.67 1.88 1.34 1 1/2" x 1" x 11/2" 101080608 1.94 1.80 1.94 1.45 11/2" x 1/4" x 1/2" 101080704 1.41 1.34 1.66 1.05 11/2" x 1/4" x 3/4" 10T080705 1.52 1.45 1.75 1.15 1 1/2" x 1 1/4" x 1" 101080706 1.65 1.58 1.80 1.25 1 1/2" x 1 1/4" x 2" 101080709 2.16 2.10 2.02 1.90 I 1/2"x1 112"x1/2" 101080804 1.41 1.41 1.16 1.15 11/2" x 1/2" x 3/4" 101080805 1.52 1.52 1.75 1.24 11/2" x 1/2" x1" 10T080806 1.65 1.65 1.80 1.30 1 1/2 x 1 1/2 x I 10T080807 1.82 1.82 1.88 1.48 I 1/2"x1 1/2"x2" 101080809 2.16 2.16 2.02 1.98 2" x 1" x 2" 101090609 2.25 2.02 2.25 2.15 2" x 1 1/4" x 2" 101090709 2.25 2.10 2.25 2.30 2" x 1/2" x 1/2" 101090804 1.49 1.41 1.88 1.50 2 x 1/2 x3/4 101090805 160 152 197 162 2" x 1/2" x " 101090806 1.73 1.65 2.02 1.64 2"x1 1/2"x1 1/4" 10T090807 1.90 1.82 2.10 1.80 2" x 11/2" x 1 1/2" 101090808 2.02 1.94 2.16 2.00 2" x 1 1/2" x 2" 101090809 2.25 2.16 2.25 2.35 2x2x1/2 101090904 1.49 1.49 1.88 1.60 2" x 2" x 3/4" 101090905 1.60 1.60 1.97 1.68 2" x2"xl" 101090906 1.73 1.73 2.02 1.85 2"x2"x1 1/4" 10T090907 1.90 1.90 2.10 2.04 2" x 2" x 1 1/2" 101090908 2.02 2.02 2.16 2.18 2"x2"x2 1/2" 101090910 2.60 2.60 2.39 3.61 2 l/2"x2' I 101100905 "1.74 1.60 2.32 2.28 O C.I. Threaded fittings are UL, cUL listed and Factory Mutual approved for 300ps1 servce. Gray iron per ASTM 126 class B. Dimensions conform to ANSI B 16.4 Class 125 except plugs conform to ASME B 16,14. Threads are NPT perANSI/ASME 131.20.1. Description F C. 1. 90 Degreed Elbow Description I Reducing 90 Degreed Elbow B j Gem --1! 0 S ITE LN_M D'flEMEffS.NJrTrEM I I" 1C90B0606 1.50 1.50 0.85 1 1/4" 1C90B0707 1.75 1.75 1.22 11/2 1, 1C90B0808 1.94 1.94 1.55 2" 1C90B0909 2.25 2.25 2.45 2 1/2" . 1C90B1OiO 2.70 2.70 4.80 Description I C. Straight Tee A A F-~-fl L I]n Gem JJB __ EMEN$1DNJ 1NOM SIZE] 111 flTEM r[Aflf]vEL 1CT060606 1.50 1.50 0.85 11/4" 1C1070707 1.75 1.75 1.22 11 ?2" 1 CT080808 1.94 1.94 1.55 1CT090909 2.25 2.25 2.45 21/2 1CT1O1O1O 2.70 2.70 6.39 Description F C. Reducing Coupling I IE1TEWCLD1MJflTEW1 I NOMSj 1 I X 1/2" 1CCR0604 1.69 0.62 1 X 3/4" 1CCR0605 1.69 0.69 NOM SIZE MEN NJ S]PTEM1 I__I E11J IA'IIB' !EKJ1fl 1 X1/2" 1C90R0604 1.26 1.36 0.44 I X 3/4" 1C90R0605 1.37 1.45 0.52 1 1/4 X 1/2" 1C90R0704 1.34 1:53 0.64 1 1/4 X 3/4" 1C90R0705 1.45 1.62 0.72 11/4" X 1" 1C90R0706 1.58 1.67 0.75 1 1/2" X 1/2" 1C90R0804 1.60 1.70 1.17 1 1/2" X 3/4" 1C90R0805 1.61 1.72 1.30 1 1/2" X 1' , 1C90R0806 1.65 1.80 0.92 1 1/2" X 1 1/4" 1C90R0807 1.82 1.88 . 1.08 2" X 1/2" 1C90R0904 1.49 1.88 1.08 2" X 3/4" 1C90R0905 1.60 1.97 1.24 2" X 1" 1C90R0906 1.73 2.02 1.40 2"X1 .1/4" 1C90R0907 1.90 2.10 1.52 2"X 11/2" 1C90R0908 2.02 2.16 1.65 Description I C. 1. 45 Degreed Elbow NOM SIZE IIIEWODILME.NISJDEJrITEM1 19400606 1.12 1.12 1 0.46 1 1/4" 1C45B0707 1.29 1.29 0.73 11/2" iC45B0808 1.43 1.43. 0.92 1C45B0909 1.68 1.68 1.50 www.sigmaco.com Cast Iron Threaded www.sigmaco.com Description I C. 1. Reducing Tee Ti-- d C&S Usno NOM SI 1IITEWCE1 ZE j[ FT5tMENION1 BLACK 1I A JEW1[C1WEIGH lx lx 1/2" 1CT060604 1.26 1.26 1.36 0.95 1x1" x 3/4" 1CT060605 1.37 1.37 1.45 1.10 1" x 1/2" x 1" 1 CT060406 1.50 ,. 1.36 1.50 1.08 lx 3/4' x1" 1CT060506 1.50 1.45 1.50 1.18 1" x 1"x 11/4" 1C1060607 1.67 1.67 1.58 1.52 1" x 1" x 1 1/2" 1CT060608 1.80 1.80 1.65 1.73 11/4" xi" x 1/2" 1CT070604 1.34 1.26 1.53 1.17 1 1/4" x 1"x 3/4" 1C1070605 1.45 1.37 1.62 1.38 1 1/4"x1"x1" lCT070606 1.58 1.50 1.57 1.47 1 1/4" x 1" x 11/4" 1CT070607 1.75 1.67 1.75 1.80 11/4"x I" xi 1/2" 1C1070608 1.88 1.80 1.82 2.05 11/4" x 1/4" x 1/2" 1CT070704 1.34 1.34 1.53 1.37 11/4" x 1/4" x 3/4" 1CT070705 1.45 1.45 1.62 1.54 11/4" x 11/4"x 1" 1CT070706 1.58 1.58 1.67 1.65 I 1/4"x1 1/4"x112" 1CT070708 1.88 1.88 1.82 2.21 11/4"x 1 1/4" x 2" 1CT070709 2.10 2.10 1.90 2.55 1 1/2" x I" x 1/2" 16T080604 1.41 1.34 1.66 1.41 1 1/2" x lx 3/4" 1CT080605 1.52 1.37 1.75 1.65 11/2"x1"x1" 1CT080606 1.65 1.50 1.80 1.65 1 1/2" x 1" x 1 1/4" 1CT080607 1.82 1.67 1.88 2.00 11/2" x 1" x 1 1/2" 1CT080608 1.94 1.80 1.94 2.30 1 1/2 x 1 1/4 x 1/2 1CT080704 1.41 1.34 1.66 1.58 '1 1/2"x I 1/4"x3/4" 1CT080705 1.52 1.45 1.75 1.72 1 1/2" x 1 1/4" x 1" 1CT080706 1.65 1.58 1.80 1.85 I 1/2"xl 1/4"x1 1/4' 1CT080707 1.82 1.75 1.88 2.22 1 1/2"xl 1/4"x1 1/2" 1CT080708 1.94 1.88 1.94 2.45 1 1/2" x 1 1/4" x 2" 1CT080709 2.16 2.10 2.02 2.80 1 1/2" x 1/2" x 1/2" 1CT080804 1.41 1.41 1.66 1.76 11/2 x 1/2 x3/4 1CT080805 152 152 175 187 1 1/2" x 1 1/2" x 1" 1CT080806 1.65 1.65 1.80 1.94 1 1/2"x1 1/2"x1 1/4" 1CT080807 1.82 1.82 1.88 2.29 1 1/2" x 1 1/2" x 2" 1CT080809 2.16 2.16 2.02 3.28 2" x I" x 2" 1CT090609 2.25 2.02 2.25 3.40 2" x 1 1/4" x 2" 1CT090709 2.25 2.10 2.25 2.80 2 x 11/2" x 1/2 1CT090804 1.49 1,41 1.88 2.09 2" x 1 1/2" x 3/4" 1CT090805 1.60 1.52 1.97 2.40 2" x 1 1/2" x 1" 1CT090806 1.73 1.65 2.02 2.54 2" x 1 1/2" x 1 1/4" 1CT090807 1.90 1.82 2.10 2.85 2" x 1 1/2" x 1 1/2" 1CT090808 1.49 1.41 1.88 2.24 2" x 1 1/2" x 2" 1C1090809 2.25 2.16 2.25 3.75 2" x 2" x 1/2" 1C1090904 1.49 1.49 1.88 2.60 2" x 2" x 3/4" 1CT090905 1.60 1.60 1.97 2.71 2" x2"x1" 1CT090906 1.73 ' 1.73 2.02 2.97 2" x 2" x 1 1/4" 1CT090907 1.90 1.90 2.10 3.32 2" x 2" x 1 1/2" 1CT090908 2.02 2.02 2.16 , 3.72 2" x2" x2 1/2" 1CT090910 2.60 2.60 2.39 5.10 Description I 7771 C. 1. Plugs 1 1 ________________________ c®us A - USTED NOM SIZE IITEMtUD'EII IMMIlI iTEM BLACK1I A 1WEIGEfli 1/2" 1CPLG0404 , 0.94 0.10 3/4" 1CPLG0505 1.07 0.17 1 CPLG0606 1.25 0.28 1 1/4" ICPLG0707 1.36 0.44 1 1/2" 1CPLGO808 1.45 0.62 ICPLGO909 1.56 0.91 Description I C. 1. Cross A A IWIVI QI7IUTEWCODEILDIMENN1rITEM I BLACK II A IEW1WELG}111 1CX0606 1.50 1.50 1.54 11/4" 1CX0707 1.75 1.75 2.40 1 1/2" 1CX0808 , 1.94 1.94 3.10 1CX0909 2.25 2.25 4.00 111/4 X 1 ICX0706 1.58 1.67 2.05 1 1/2"X I" 1CX0806 1.65 1.80 2.40 2"X 1" 1CX0906 1.73 2.02 2.75 Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME 131.20.1 Description I Black Steel LENGTH NOMINAL SIZE i 1/8" II 1/4" IL 3/8" II 1/2" iL 3/4" it 1" IL 11/4" II 11/2" II 2" CLOSE 1NB0101 1N80201 INB0301 1NB0401 I 1NBO501 1NBO601 1NB0701 1NB0801 1NBO901 11/2° 1NBO108 1NB0208 1NB0308 1NB0408 1NB0508 NA NA NA NA 2" 1N80109 1NB0209 1N60309 1NB0409 1NB0509 1NB0609 1NB0709 1NB0809 NA 2 1/2" 1NBO110 1NB020I0 1NB03I0 INBO410 INB05I0 1NBO610 1NB0710 1NBO810 1NBO910 3" 1NBO11I INBO211 1NB03II INB0411 1NBO5II INBO611 1NB0711 1NBO811 INBO9II 31/2° 1NB0111-5 IN60211-5 1NB0311-5 1NBO411-5 1NB0511-5 1NB06I1-5 INBO7II-5 1NB0811-5 1NB0911-5 4" 1NBO112 1NB0212 1NB0312 1NB0412 1NB0512 1NB0612 1NB0712 1NB0812 1NB0912 4 1/2" INBO112-5 1NB0212-5 1NB0312-5 1NB0412-5 1NB0512-5 1NB0612-5 1NB0712-5 1NB0812-5 1NB0912-5 5" 1NBO113 1NB0213 1NB0313 1NB0413 1NB0513 1NB0613 1NB0713 1NB0813 1NB0913 5 1/2" 1NBO113-5 1N80213-5 1NB0313-5 1NB0413-5 1NB0513-5 1NB0613-5 1NB0713-5 1NB0813-5 1NB0913-5 6" 1NB0114 1NB0214 1NB0314 1NB0414 1NB0514 1NB0614 1NB0714 1NB0814 1NB0914 6 1/2" INBO114-5 1NB0214 -5 1NB0314-5 1NB0414-5 1NB0514-5 1NB0614-5 1NB0714-5 1NB0814-5 1NB0914-5 7" NA NA NA. NA NA 1NB06147 INB07147 1NB08147 1NB09147 7 1/2° NA NA NA NA NA 1NB06147-5 1NB07147-5 1NB08147-5 1NB09147-5 8" 1NB0115 1NB0215 1NB0315 1NB0415 1NB0515 - 1NB0615 1NB0715 1NB0815 1NB0915 81/2° NA NA NA NA NA 1NB0615-5 1NB0715-5 1NB0815-5 1NB0915-5 9" 1NBO116 1NB0216 1NB0316 1NB0416 1NB0516 1NB0616 1NB0716 1NB0816 1NB0916 9 1/2" NA NA NA NA NA IN B0616 -5 1NB0716-5 1NB0816-5 1NB0916-5 10" 1NBO117 1NB0217 1NB0317 1NB0417 1NB0517 1NB0617 1NB0717 1NB0817 1NB0917 10 1/2" NA NA NA NA NA 1NB0617-5 1NB0717-5 1NB0817-5 1NB0917-5 11" 1NBO118 1NB0218 1NB0318 1NB0418 1NB0518 1NB0618 1NB0718 I 1NB0818 1NB0918 111/2" NA NA NA NA NA 1N80618-5 1NB0718-5 1NB0818-5 1NB0918-5 12" 1NBO119 1NB0219 1N80319 1NB0419 1N80519 1NB0619 1NB07.19 1NB0819 1NB0919 F LENGTH F NOMINAL SIZE I 2 1/2" ii 3" ii 4" II 6" CLOSE 1NB1001 1NB1101 1NB1201 1NB1401 1NB1011 1NB1111 NA NA 31/2" 1NB1011-5 1NB1111-5 1NB1211-5 NA 1NB1012 1NB1112 1NB1212 NA 4 1/27 1NB1012-5 1NB1112-5 1NB1212-5 NA INBI013 INBI1I3 1NB1213 NA 51/2" INB1013-5 1NB1113-5 1N81213-5 NA 1NBI014 1NB1114 1NB1214 1NB1414 8" 1NB1015 INB1115 1NB1215 1NB1415 9. 1NB1016 1NB1116 1NB1216 1NB1416 INB1017 1NB1117 1N81217 1NB1417 1NB1018 1NB1118 1NB1218 1NB1418 INB1019 1NB1119 1NB1219 1NB1419 www.sigmaco.com `ne-d I I a am -W- 0, 1 1 I -,m. NI a 11 Carbon Steel schedule 40 welded pipe nipples threaded to spec. ANSI/ASME B1.20.1 Galvanized to spec. ASTM A 153- for zinc coating. Description I Galvanized Steel— II NGL]L NOMINAL SIZE 1/8" II 114" _j [_318" 11 112W 11] L i4" _] 1" II 1114" ILl 1/2" J[ 1 1/2" 1 CLOSE 1NG0101 ING0201 1NG0301 1NG040I 1NGO5O1 ING060I 1NG070I INGO8OI INGO9O1 1" NA INGO2O1-1 NA NA NA NA NA NA NA 1 1/4" NA NA NA NA NA NA NA NA NA 11/2" 1NG0108 1NG0208 1NG0308 1NG0408 1NG0508 NA NA NA NA 2" 1NG0109 1NG0209 1NG0309 1NG0409 1NG0509 1NG0609 1NG0709 1NG0809 NA 2 1/2" ING011O ING02010 1NG0310 1NG0410 1NG0510 ING06I0 1NGO71O 1NG0810 1NG0910 3" 1NG0111 1NG0211 1NG0311 1NG0411 1NG0511 1NG0611 1NG0711 1NG0811 1NG0911 3 1/2" 1NG0111-5 INGO211-5 1NG0311-5 1NG0411-5 1NG0511-5 1NGO611-5 1NG0711-5 1NG0811-5 1NG0911-5 4 1NG0112 1NG0212 1NG0312 1NG0412 1NG0512 1NG0612 1NG0712 1NG0812 1NG0912 41/2" 1NG0112-5 1NG0212-5 1NG0312-5 1NG0412-5 1NG0512-5 1NG0612-5 1NG0712-5 1NG0812-5 1NG0912-5 51, ING0113 1NG0213 1NG0313 1NG0413 1NG0513 1NG0613 1NG0713 1NG0813 1NG0913 5 1/2" ING0113-5 1NG0213-5 1NG0313-5 1NG0413-5 1NG0513-5 1NG0613-5 1NG0713-5 1NG0813-5 1NG0913-5 6" 1NG0114 1NG0214 1NG0314 1NG0414 1NG0514 1NG0614 1NG0714 1NG0814 1NG0914 6 1/2" 1NG0114-5 1NG0214-5 1NG0314-5 1NG0414-5 1NG0514-5 1NG0614-5 1NG0714-5 1NG0814-5 1NG0914-5 7 NA NA NA 1NG04147 NA 1NG06147 1NG07147 1NG08147 1NG09147 8" ING0115 1NG0215 1NG0315 1NG0415 1NG0515 1NG0615 1NG0715 1NG0815 1NG0915 81/2 NA NA NA 1NG0415-5 NA NA NA NA NA 9" 1NG0116 1NG0216 1NG0316 1NG0416 1NG0516 1NG0616 1NG0716 1NG0816 1NG0916 10" 1NG0117 1NG0217 1NG0317 1NG0417 1NG0517 1NG0617 1NG0717 1NG0817 1NG0917 11" 1NG0118 1NG0218 1NG0318 1NG0418 1NG0518 1NG0618 1NG0718 1NG0818 1NG0918 12 1NG0119 1NG0219 1NG0319 1NG0419 1NG0519 1NG0619 1NG0719 1NG0819 1NG0919 LENGTH I NOMINAL SIZE F 2 1/2" II CLOSE 1NG1001 1NG1101 1NG1201 1NG1401 3" 1NG1011 1NG1111 NA NA 3 1/2" 1NG1011-5 1NG1111-5 NA NA 4" 1NG1012 ING1II2 1NG1212 NA 4 1/2" 1NG1012-5 1NG1112-5 1NG1212-5 NA 5" ING1013 1NGI113 1NG1213 NA 5 1/2" INGI013-5 1NG1113-5 1NG1213-5 NA 6" INGI014 1NG1II4 1NG1214 1NG1414 7" NA 1NG1114-5 NA NA 8" 1NG1015 1NG1115 1NG1215 1NG1415 9" 1NG1016 1NG1116 1NG1216 1NG1416 10" 1NG1017 1NG1117 1NG1217 1NG1417 1V 1NG1018 1N61118 1NG1218 1NG1418 12" 1NG1019 1NG1119 1NG1219 1NG1419 www.sigmaco.com M MT, N -Har AM ME I O Manufactured from carbon steel (which conforms to ASTM A 865 standard) O Threads conform to ASME B1.20.1 standards for pipe threads. O Sizes 2" and below are straight tapped and 2 1/2" and above are tapper tapped. Description 1 1 ISize Item Code D L 1/2" 1MCC0404 1.063" 1.563" 3/4" 1MCC0505 1.313" 1.625" 1MCC0606 1.576" 2.00" I 1-1/4" 1MCC0707 1.900" 2.063" 1-1/2" 1MCC0808 2.200" 2.063" 1MCC0909 2.750" 2.125" 2-1/2" 1 MCC1 010 3.250" 3.125" IMCCI111 4.00" 3.250" IMCCI2I2 5.00" 3.500" www.sigmaco.com victaulic.com I FireLock® Fittings I Publication 10.03 Flow Data: Frictional Resistance Actual Equivalent Feet/meters of Straight Pipe' No. 002 Nominal Outside Size Diameter Elbows Straight Tee No. 001 No. 003 inches inches mm mm 900 Elbow 45° Elbow Branch Run 11/4 1.660 - - - - 32 42.4 - - - - 1 1/2 1.900 - - - - 40 1 48.3 - - - - 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 1 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 139.7 mm 5.500 8.3 4.1 20.6 8.3 139.7 2.5 1.3 6.3 2.5 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 165.1 mm 6.500 9.8 4.9 24.5 9.8 165.1 3.0 1.5 7.5 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 1 The flow data listed is based upon the pressure drop of Schedule 40 pipe. General Notes: NOTE: When assembling FireLock EZ couplings onto end caps, take additional care to make certain the end cap is fully seated against the gasket end stop. For FireLock EZ Style 009N/009H couplings, use FireLock No. 006 end caps containing the "EZ" marking on the inside face or No. 60 end caps containing the 'QV EZ" marking on the inside face. Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. Installation Reference should always be made to the I-lOU Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaalic.com. Warranty Refer lathe Warranty section of the current Price List or contact Victaulic for details. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Trademarks Victaulic° is a registered trademark at Victaulic Company. 10.03 1539 Rev M Updated 12/2014 © 2014 Victaulic Company. All rights reserved. victaulic.com 3 x, /--~_C_t3_UhCr F! ess than Wood Flooding Product Features 2" nominal e.idth ll1l2') I NKa o pre-drilling required. Not less than I 'Quick to install using the Sammy 3" nominal thickness (2-112') Nut Driver with an 18V cordless 1 (depth or side Wood Joist 0 river. otverhcal member) .. ... 1" -'Saves time from traditional Double Sheetock methods. Ceiling .. . 'Reduces installation cost I . I 'Made in the U.S.A. L1AJ 114" 8002957 GST 100 1/4x1" 25 125 670 (3/4" Ply) 114 8003957 GST 200 1/4s2 1760 (Fir) 25 125 114 8004957 GST 300 1/4 x 3 2060 (Fir) 25 125 1 3/8 8006957 GST .75 1/4x 3/4 564 (3/4" Ply) 25 125 - 3/8 8007957 GST 10 1/4 x1' 300 25 125 8008957 GST20 4n2" 1760 (Fir) 850 1415 25 125 3 /8 8068925 GST 20-SS 4/452 1760 (Fir) 850 25 125 3/8 8009925 GST 25-380 3/8x2-1/2" 2113 (Fir) 1500 25 125 - 3/8 8010957 GST 30 1/4 x3 2060 (Fir) 1500 1475 25 125 #14 Black Nut Driver 3/8" 8069925 GST 30-SS 1/4x3" 2060 (Fir) -- 25 125 Part#8113910 3/8" 8011925 GST 4O 1/4x4" 2180 (Fir) 25 125 3/8 8012925 GST 60 1/4x6" 2230 (Fir) 25 125 - 1/2 8013925 GST2 - 1/4 x 2 1760 (Fir) 25 125 1/2" 8014925 GST 2.5-380 3/8x2-1/2" 2113 (Fir) 25 125 1/2 8015925 GST3 - 1/403 2275 (Fir) 25 125 1/2 8016925 GST4 1/4x4" 2180 (Fir) 25 125 l/T 8017925 GST6 1/4x6" 2230, (Fir) 125 #14 SW Red Nut Driver Part # 8114910 e " Product Features Eliminates distortion of threaded rod. • Saves time from traditional methods. , • Accommodates up to 3%" x 12 pitch roof. • Reduces installation cost Allows 17" deflection from vertical. • Made in the U.S.A. I l - . i L' l!I . IIfl1) tk/8r} - iKi) 7 SH-GST2O 1/4n2' 1257 (Fir) 1050 - - 1475 25 125 125 3,o 814197 SH-GST 30 1/403 1720 (Fir) 1500 1475 25 125 #14 Black Nut Driver SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into Part #8113910 contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate not driver for installations. For the most up to date information, visit www.sammysuperscrew.com 4 S 17 W-1 Not less than 2" nominal width / • 4" Product Features (1-112") up to 3-1/2" pipe; not less than No pie-drilling required. 3" (2-1/2") nominal width 4" & 5" pipe - Floor Joist Quick to install using the Sammy Minimum 2-itt from bottom for Nut Driver with an 18V cordless branch lines. fanimum 3" from bottom for mainlines. Exception: This drill/driver. requirement shalt not apply to 2" or thicker nailing stops resting on top of steel beams. Saves time from traditional ' methods. Reduces installation cost Made in the U.S.A. . . - . _______ - I tnmejI8J RR IF #14 SW Red Nut Driver Part# 8114910 pMn - MM29 — 1/4" 8018957 SWG 100 1/4x1" 622 (Fir) 25 125 1/4 8019957 SWG 200 1/4 x 2 1725 (Fir) 25 125 3/8 8020957 SWG 10 1/4 xl 622 (Fir) 300 25 125 3/8" 8021957 SWG 20 1/402" 1725 (Fir) 1050 25 125 8073925 SWG 20-SS 1/402 1725 (Fir) 850 25 125 D 3/8 8022925 SWG 25-380 3/8021/2 - 1/403 2249 (Fir) 1500 25 125 3/8 8023925 SWG 30 - 1884 (Fir) 25 125 110 ThPS* JIITO WOOD & ST I ATSTEPS - ______ Insert the appropriate nut driver into a 3/8" or 112"portab!e drill 1. Insert the appropriate nut driver into a 3/8" or 1/2" portable drill. Insert the SAMMYS into the #14 (black) nut driver (p/n 8113910). Drill 2. Insert the SAMMYS into the #I4SW(red) nut driver (p/n 8114910). With drill should be in a vertical position. unit in a horizontal position and at a right angle to the structural member, begin installation. Push the face of the nut driver tight to the member; When the nut driver spins freely on the SAMMYS, stop drill and remove. 3. When the nut driver spins free on the SAMMYS, stop the drill and remove. The SAMMYS is now ready to receive 1/4' 3/8' 1/2" or metric all thread rod, bolt stock. (The 1/2" requires the #I4SW red nut driver) 4. The unit is now ready to receive 1/4' 3/8" or metric all thread rod or bolt stock. Note: When installing DSTR, follow the above instructions, then add retainer nut and torque to 20 foot lbs. for maximum Note: When installing SWDR, follow the above instructions, then add retainer nut pullout in purlln steel and torque to 20 foot lbs. for maximum pullout in purlin steel. __ b1rAfl__ E11 SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. L ACCESSORIES Application Installation ~teps' 1. Pie-drill a51ole with a regular drill or hole saw. wing nut and and begin 0\ 11 When bolt secure and nut driver spins free, stop drill motor ." and remove. Hollow core SST screw is now ready to receive 1/4, 3/8°, or Metric all Concrete thread rod or bolt stock. I - 1/4" 8063925 SST 300 1/4 x 3° 404 (2 Layers 5/8 Rock) r 450 (Lath & Plaster) 25 125 -4 Black 404 (2 Layers 5 Rock) 3/8" 8064925 SST 30 1/4 x 3 450 (Lath & Plaster) 25 125 Nut Driver Part 8113910 ;Z7 3/16" eyelet to accommodate common wire size. cc approvals can be found at wltwbuildeu.com under Evaluation Report # ER-5367. icc STEEL 8107957 CWSD1 Teks 1/4x1" 2° 472 (20 ga) 16 ga. 170 (20 ga.) 25 125 cc rQ0E 8190957 CWSD 15" Gimlet 1/4 x 1-1/7 2-3/4" 472 (20 3a) 20 ga. 170 (20 ga.) 25 125 !c.. cyri.-D2 114xJ 3.114 - 472 (20 ga), t6 ga 170 (20 ga.) 2 I cwii icc 8iio9io CWIT instatiation Tool Installation Toot Does not comply with ROHS requirements Component of State of California OSHPD Approved Seismic Restraints System -. t9• 98- Rod Stiffener Fi8B - Rod Stiffener wlBreak-off Bolt Head Size Rang Secures 3/8" thru 7/8" hanger rod Material - Steel Ca n Function - Securhannel to hanger rod for vertical seismic bracing. Approvals - lnclude. our Seismic Restraints Catalog approved FIG. 98 Finish - Electro Galvanized Note - Available in HDG finish or Stainless materials. Order By - Figure number FIG. 98B Fig. 99 - All Thread Rod Cut to Length Size Range - Secures 3/8" thru 7/8" rod in 1 "increments Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter, rod length and finish Dimensions 'pd Max. Rec. Load Lbs. STh For Service Temp 650°F 3/8 730 1/2 N., 1350 3/4 7/8 Size Range - Secures 3/8" thru 11/2" rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note - Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Fig. 100 -All Thread Rod Full LAnnth Dimensions • Weights Max Rec. Load Lbs. Rod For Service Temps Approx. Size 650°F wt./100 1/4 240 12 3/8 730 29 1/2 1350 53 5/8 2160 84 3/4 3230 123 7/8 4480 169 1 5900 222 11/4 9500 360 11/2 13800 510 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800786.5266 www.tolco.com Pipe Clamps TOLCOtm Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap Size Range: 3/4 (20mm) thru T (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Fig. 22 can be installed on the top of a beam, but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to support CPVC pipe from under a flat horizontal surface, such as a ceiling. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm) steel using (1) 1/4 x V tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design protects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Part number and CPVC pipe size. * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. C & LISTED CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size Wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (ml in. (mm) Lbs. (kg) 22-3/4 3/4' (20) 2/16" (61.9) 1/16" (33.3) 1/16" (30.2) 51/2 (1.67) /16' (1.9) 9 (4.1) 22-1 1" (25) 211/16' (68.3) 11/16' (36.5) 1/16" (30.2) 6 (1,83) /16' (1.9) 9 (4.1) 2211/4 11/4' (32) 31/16 (17.8) 1/8" (42.3) 1/16" (30.2) 61/2 (1.98) /16' (7.9) 11 (5.0) 22-11/2 11/2' (40) 3/16" (84.1) 1/4 (44.4) 1/16" (30.2) 7 (2.13) /16" (7.9) 12 (5.4) 22-2 2" (50) 33/4' (95.2) 21/8" (54.6) 1/16' (30.2) 8 (2.44) /16" (1.9) 15 (6.8) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 95 B-Line series Pipe Hangers & Supports Pipe Clamps TOLCOTM Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Size Range: 3/4" (20mm) thru 3" (80mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Fig. 23 can be installed on the top, bottom or side of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cJJL) sizes 3/4" (20mm) thru 2" (50mm) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.9mm) steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Part number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Part No CPVC Pipe Size in (mm) A in (mm) B in (mm) C in. (mm) Max. Hanger Spacing Ft. (ml Fastener Hex Head Size in (mm) Approx. Wt/100 Lbs. (kg) 23-3/4 3/4 (20) 31/8 (79.4) 1/16 (39.7) 1/16° (30.2) 51/2 (1.67) /16 (7.9) 9 (4.1) 231 1 (25) 3/8 (857) 111/16 (429) 1/16 (302) 6 (183) /16 (79) 9 (41) 23-11/4 11/4 (32) 4 /16 (106.4) 2/32" (53.1) 1/16 (30.2) 61/2 (1.98) /16' (7.9) 11 (5.0) 23-11/2 11/2° (40) 4 /16° (112.7) 2/32 (56.3) 1 /16° (30.2) 7 (2.13) /16 (7.9) 12 (5.4) 23-2 2 (50) 4 /8° (123.8) 2/16 (61.9) 1/16° (30.2) 8 (2.44) /16° (7.9) 15 (6.8) 23_21/2 21/2 (65) 5/8 (136.5) 211/16 (68.3) 1/16° (30.2) Consult Factory /16 (7.9) 22 (10.0) 23-3 3 (80) 6 (152.4) 3 (76.2) 1/16 (30.2) Consult Factory /16 (7.9) 25 (11.3) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 97 B-Line series Pipe Hangers & Supports Pipe Clamps TOLCOTm Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Side Mounted Size Range: 3/4' (20mm) thru 2' (50mm) CPVC pipe Material: Pre-Galvanized Steel Function: Intended to perform as a hanger to support CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge (0.912mm) steel using (2) 1/4 x 1 tek type screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features: Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish: Pre-Galvanized Order By: Part number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing Head Size wt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) Ft. (m) in. (mm) Lbs. (kg) 24-/4 3/4° (20) 25/16' (58.7) 15/32 (27.8) 1/16 (30.2) 51/2 (1.67) 5/16" (7.9) 9 (4.1) 24-1 1° (25) 2/8" (66.7) 1/16' (33.3) 1/16' (30.2) 6 (1,83) /16 (7.9) 9 (4.1) 24-11/4 11/4 (32) 3 (762) 11/2 (381) 1/16 (302) 61/2 (198) /16 (79) 11 (50) 24-11/2 11/2 (40) 31/4 (825) 1/8 (423) 1/16 (302) 7 (213) /16 (79) 12 (54) 24-2 2° (50) 311/16' (93.7) 127/32' (43.6) 1/16 (30.2) 8 (2.44) /16" (7.9) 15 (6.8) All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports 98 Eaton Pipe Clamps TOLCO Fig. 28M - Offset Hanger & Restrainer for CPVC Plastic Pipe Size Range: 3/4 (20mm) thru 2" (32mm) Material: Steel, Pre-Galvanized Function: Designed to be used as a hanger and restrainer for CPVC piping where the "stand-off" design will ease installation by eliminating the need for wood blocking. Features: Flared edge design protects CPVC pipe from any rough or abrasive surfaces Unique snap-on design holds pipe firmly in place and allows retrofit type of installation The "Stand-Off" design eliminates the need for wood block extension Can be installed on horizontal or vertical piping regardless of mounting surface orientation Attaches easily to wood structure with two hex head self-threading screws furnished with product Installs easily using rechargeable electrical driver with /16" (7.9mm) extension socket eliminating impact tool damage to pipe Attaches easily to steel, minimum 18 gauge (1.024mm) with 121 1/4" x 1" tek type self drilling tapping screws cULus Listed as a hanger and a restrainer for fire sprinkler piping Installation Note: When installed in wood structural members and threads from the #10 x 1. screws are exposed, use Fig. 27B speed nut to secure Approvals: Underwriters Laboratory Listed in the USA (UL) and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. I V Order By: Part number and pipe size Patent #7,744,042 C @V$ LISTED Fig. 27B (2) Required ----------- 4 .4 .4 IL I 1LJ Restraint 1 Hanger and Restraint j Application Fig. 27B (1) Required I High Side of Hanger Restraint "( Detail A Hanger Application r'. Pipe Size A Hole Dia. B C Max Spacing* Approx. '.Nt./100 Part No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-3/4 3/4" (20) 2" (50.8) /16" (4.8) 3/16" (84.1) 5'-6" (1676) 9 (4.1) 28M-1 1" (25) 21/8" (54.0) /16" (4.8) 31/2" (88.9) 6'-0" (1829) 12 (5.4) 28M-1'/4 1 1/4" (32) 2/16' (58.7) /16" (4.8) 31/f (88.9) 6'-6" (1981) 13 (5.9) 28M-11I2 11/2" (49) 2/16" (61.9) /16" (4.8) 3 /8" (98.4) 7-0" (2133) 14 (6.3) 28M-2 2" (50) 2/8" (66.7) /16" (4.8) 4/16 (112.7) 8'-0" (2438) 15 (6.8) Required per NFPA 13 for CPVC plastic pipe All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line series Pipe Hangers & Supports 102 Eaton ØTaLccr c®Us <8> LISTED Set Scret Inc All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Pipe Hangers & Supports 170 B-Line by TOLCOTM Seismic Bracing Fig. 4L - Longitudinal "In-Line" Sway Brace Attachment Size Range: 2" (50mm) through 8" (200mm) IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 21/2 (65mm) through 8" (200mm) pipe. Approved by Factory Mutual Engineering (FM), 2" (50mm) through 8" (200mm) pipe. Installation Instructions: Fig. 4L is the braced pipe attachment component of a longitudinal sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO structural attachment component to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts. Then engage bracing pipe into jaw opening and tighten set screw until head snaps off. Jaw attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish. 4 lay Riser Brace -Way Riser Brace (plan view)) I. Max. Rec. Load *Max. Design Load Approx. Part Size A I I Bolt Size (cULuc) (FM) wt./100 lb s. l. l2l (52.4) ' /2"-13 ' 2015 ' (8.96) ' -- (--) ' 247 (112,0) 4I..21/2 21/2 (65) 6/16' (163.5) 21/2' (63.5) 2/4' (69.8) 1/2 13 2015 (8.96) 3000 (13.34) 253 (114.7) 41-3 (80) (177.8) 2/4' (69.8) 31/16" (778) 1/2"..13 2015 (8.96) 1550 (6.89) 268 (121.5) 41.-4 (100) 81/2 (215.9) 3/8" (85.7) 311/16" (937) 1/2"_13 2015 (8.96) 1550 (6.89) 348 (157.8) 4L-5 (125) 93/4" (247.6) 3/8' (98.4) 4/8" (111.1) 1/2"..13 2015 (8.96) 1450 (6.45) 380 (172.3) 4L-6 (150) 111/2" (292.1) 5" (127.0) 51/8 (130.2) 1/2 ..13 2015 (8.96) 1450 (6.45) 640 (290.3) 41-8 (200) 131/4 (336.5) 5/8" (142.8) 5/8" (142.9) 1/2"..13 2015 (8.96) 1450 (6.45) 1 728 1 (330.2) Pipe Max Rec.1i1T *Max.Design a.. 0) r ' 2Q15 (8 96) 41_..21/2 21/2 (65) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590(7.07) 4L-3 3 (80) 2015 (8.96) 1030 (4.58) 1180 (5.24) 1420 (6.31) 1590(7.07) 4L-4 (100) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3,96) 990 (4.40) 4L-5 (125) 2015 (8.96) 530 (2.36) 730 (3.25) 890 (3.96) 990 (4.40) 41-6 (150) 2015 (8.96) 530 (2,36) 730 (3.25) 890 (3.96) 990 (4.40) 4L-8 8" 1 (200) 2015 (8.96) 490 (2.18) 680 (3.02) 830 (3.69) 930 (4.13) * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? the installation angle measured from the vertical. FM approved when used with 1", 11/4 , 11/2" or 2" Sch. 40 brace pipe. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. Seismic Bracing TOLCO Fig. 1001 - Sway Brace Attachment Component of State of California OSHPD Approved Seismic Restraints System Size Range: Pipe size to be braced: 1 125mm) thru 8' (200mm) IPS. * Pipe size used for bracing: 1' (25mm) and 11/4' (32mm) Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. LISTED The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS. Field adjustable, - making critical pre-engineering of bracing pipe length unnecessary. Unique design g requires no threading of bracing pipe. Can be used as a component of a four-way riser brace. Comes assembled and ready for installation. Fig. 1001 has built-in AW visual verification of correct installation. See installation note below. Set Screws I Installation Note: Position Fig. 1001 over the pipe to be braced and tighten Included two hex head cone point set screws until heads bottom out. A minimum of 1' 125mm1 pipe extension is recommended. Brace pipe can be installed on top or Pipe Max. Horizontal Design Load (UI)- Lbs. 11 bottom of pipe to be braced. Size For Brace Pipe Size 1"/ 11/4" 1 Approvals: Underwriters Laboratories Listed in the USA and Canada (cULus). Sch. 7 Sch. 10 Sch. 40 Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints in. (mm) 1"/11/4" 1"/11/4" 1"/11/4 Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement 1,' (25) --I-- 1000/1000 1000/1000 information relating to OSHPD projects, please refer to the TOLCO Seismic 11/4" (32) 1000/1000 1000/1000 1000/1000 Restraint Systems Guidelines, OPA-0300-10. i'll" (40) 1000/1000 1500/1500 1500/1500 Finish: Plain or Electra-Galvanized. Contact customer service for alternative (50) 1000/1000 2015/2015 2015/2015 finishes and materials. 21/2" (65) 1600/1600 2015/2765 2015/2765 Order By: Indicate pipe size to be braced followed by pipe size used for bracing, figure number and finish. (80) 1600/1600 2015/2765 2015/2765 Important Note: Fig. 1001 is precision manufactured to perform its function as (100) 1600/1600 2015/2765 2015/2765 a critical component of a complete bracing assembly. To ensure performance, the 6" (150) 1600/1600 2015/2765 2015/2765 UL Listing requires that Fig. 1001 must be used only with other TOLCO bracing 8" (200) 1600/ 1600 2015/2765 2015/2765 products. Part Number & Approx. Wt/100 Max. Horizontal Design Load (FM) Pipe For Sch. 1, Sch. 10, & Sch, 40 Pipe 1.Z3 Size 1" (24mm) Brace Pipe 11/4" (32mm) Brace Pipe 300-440 450-590 600-740 750-900 in. (mm) Lbs. (kg) Lbs. (kg) Lbs. (kN) Lbs. (kN) Lbs. (kN) Lbs. (kN) (25) 1001-1 X 100.0 (45.3) 1001-1 X 11/4 118.0 (53.5) 1800 (8.00) 2550 (11.34) 3120 (13.88) 3490 (25.52) 11/4" (32) 1001-11/4 X 100.0 (45.3) 1001.11/4 X 11/4 114.0 (51,7) 1230 (5.47) 1740 (7.74) 2140 (9.52) 2380 (10.58) 11/2" (40) 1001-1'/2X 1 100.0 (45.3) 1001-1'/2X 11/4 115.0 (52.1) 1230 (5.41) 1740 (1.74) 2140 (9.52) 2380 (10.58) (50) 1001-2 X 108.0 (49.0) 1001-2 X 11/4 121.0 (54.9) 1230 (5.47) 1740 (1.74) 2140 (9.52) 2380 (10.58) 21/2" (65) 1001.21/2 X 138.6 (62.8) 1001-21/2 X 11/4 160.4 (12.7) 800 (3.56) 1130(5.02) 1380 (6.14) 1540 (6.85) (80) 1001-3 X 147.2 (66.7) 1001-3 X 11/4 168.7 (76,5) 850 (3.18) 1200 (5.34) 1470 (6.54) 1640 (7.29) (100) 1001-4 X 160.9 173.01 1001-4 X 11/4 182.4 (82.7) 850 (3.78) 1200 (5.34) 1470 (6.54) 1640 (7.29) 6" (150) 1001-6 X 190.0 (86.2) 1001-6 X 11/4 211.4 (95.9) 510 (2.21) 730 (3.25) 890 (3.96) 990 (4.40) 8" (200) 1001-8 X 217.4 (98.6) 1 1001-8 X 11/4 238.8 (108.3) 1 510 (2.27) 730 (3.25) 890 (3.96) 990 (4.40) 1 FM Approved when used with 1 or 11/4 inch NPS Schedule 40 GB/I 3091 EN 10255H, or JIS G3451 steel pipe as the brace member. 2 Load rating for LW above refers to FM Approved Lightwall Pipe commonly referred to as "Schedule 7". These ratings may also be applied when EN 10220 and GB/I 8163 steel pipe. Load rating for Schedule 10 above may be applied to GB/I 3092,EN 10255M and H, or JIS G3454, FM Approved Thinwall, or Schedule 40 steel pipes. Note: See UL load ratings in UL Listed Design Load chart shown under drawing. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. Eaton 193 B-Line series Pipe Hangers & Supports Mounting Hardware Is Not Included Seismic Bracing Component of State of ® ToLCo California OSHPD Approved Seismic Restraints System c®us USTED Fig. 909 - No-Thread Swivel Sway Brace Attachment Size Range: 1(25mm) bracing pipe. For brace pipe sizes larger than 1(25mm), use Fig. 980. Available with holes for j"-16 thru /4"-10 fastener attachment. Material: Steel, hardened cone point set screw Function: The structural component of a sway and seismic bracing system. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 (2010) 9.3.5.8.4 indicates clearly that fastener table load values are based only on concentric loading. No threading of the bracing pipe is required. Open design allows for easy inspection of pipe engagement. Application Note: Fig. 909 is used in conjunction with the Fig. 1000, Fig. 1001, Fig. 4 (A) or Fig. 4L pipe clamp, and joined together with bracing pipe. Sway brace assemblies are intended to be installed in accordance with NFPA 13 (or TOLCO State of California OSHPD Approved Seismic Restraint Manual) and the manufacturer's installation instructions. The required type, Set number and size of fasteners used for the structure attachment fitting shall Incl be in accordance with NFPA 13 and/or OSHPD. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions: Fig. 909 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the bracing pipe and TOLCO braced pipe' attachment, Fig. 1000, 1001, 4A, 4B or 4L to form a complete bracing assembly. NFPA 13 and/or OSHPD guidelines should be followed. To Install: Place the Fig. 909 onto the bracing pipe. Tighten the set screw until the head bottoms out on surface. Attachment can pivot for adjustment to proper brace angle. Finish: Plain. Contact B-Line for alternative finishes and materials. Order By: Figure number, fastener attachment size and finish. Eaton's B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components, resulting in a listed seismic bracing assembly. B-Line's warranty for seismic bracing components will be the warranty provided in B-Line's standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from B-Line's warranty, Eaton's B-line Business makes no warranty relating to B-Line's seismic bracing components that are combined with products not provided by Eaton's B-Line Business. B-Line All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are In millimeters unless otherwise specified. by 179 Pipe Hangers & Supports 47Fcon. SEISMIC BRACES (~AWIL Fig. AF035 (Formerly Afcon Fig. 035) Model K Brace Clamp Size Range: Carbon Steel Service Pipe: 1" through 12' DN25 through DN200 CPVC Steel Service Pipe: 1" through 3" Brace Pipe: 1" through 2" and DN25 through DN50 Material: Carbon Steel Strap and Ductile Iron Cast Hoop Ends Finish: E Plain or LI Electro-Ga Ivan ized per ASTM B633 Service: Designed to rigidly brace piping systems subjected to lateral seismic loads. Approvals: cULus Listed (UL 203a) and FM Approved (FM 1950-10 & FM 1950- 13). Complies with the hanging and bracing requirements listed in NFPA 13. Features: Unique design provides solutions for carbon steel and CPVC pipe. Beveled edge design helps protect the CPVC pipe from any rough surface and eliminates pipe abrasion. 3' Large installation hole in the cast hoop ends allows the brace pipe to LISTED APPROVED pass through easily without interference. Visual indication of proper assembly when the head of the set screw bottoms out on the cast hoop ends. Installation Instructions: Place the Model K Brace Clamp over the service pipe to be braced and slide the Sch. 40 brace pipe through the cast hoop ends. The end of the brace pipe must extend at least 1" past the cast hoop ends. Note: The brace pipe may be installed above or below the service pipe. Ensure brace pipe is set to the desired installation brace angle. Torque the set screws alternately and equally until the head of the set screw bottoms out on the cast hoop ends. For riser/4-way brace installations, two Model K Brace Clamps must be installed within 6" of each other. For CPVC installation, ensure the legs of the Model K Brace Clamp strap are parallel to each other and perpendicular to the brace pipe prior to installation. Fire Protection applications shall also be installed per the requirements of NFPA 13 and local codes. Patents: No. 7,516,922, No. 7,523,895 Ordering: Specify service pipe size, brace pipe size, figure number, finish and description. Notes: Anvil lnternationat brand bracing components are designed to be compatible ONLY with other Anvil International® brand bracing components, resulting in a Listed seismic bracing assembly. updated UL listing information may be viewed at www.ul.com and updated FM approval information may be viewed at www.approvalguide.com. Disclaimer: Anvil International ("Anvil") does not provide any warranties and specifically disclaims any liability whatsoever with respect to Anvil bracing products and components that are used in combination with products, parts or systems not manufactured or sold by Anvil. In no event shall Anvil be liable for any incidental, direct, consequential, special or indirect damages or lost profits where non-Anvil bracing components have been, or are used. SeisBrace® Seismic Fire Protection Design Tool may be accessed at www.seisbrace.com {I!I'lINFORMATION i Project: APPROVAL STAMP Approved Address: L] Approved as noted Contractor: El Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-3.1 9 - 4" 5-12" 47,con. SEISMIC BRACES =00 Fig. AF03 5 (Formerly Afcon Fig. 035) Model K Brace Clamp (cont.) 1' Mm. Set Screw Installation FIG. AF035: DIMENSIONS (IN) e WEIGHT_(LBS) Service Pipe Size 1"/DN25 Brace Pipe Weight 11/4"/DN32 Brace Pipe Weight 11/2"/DN40 Brace Pipe Weight 2"/DN50 Brace Pipe Weight 1 (0N25) 1.60 1.80 2.00 2.28 11/4(DN32) 1.68 1.88 2.08 2.36 11/2(DN40) 1.64 1.84 2.04 2.32 2 (DN50) 1.88 2.08 2.28 2.56 21/2 1.90 2.10 2.30 2.58 DN65 2.00 2.20 2.40 2.68 3 (DN80) 2.10 2.30 2.50 2.78 4 (DNlOO) 2.20 2.40 2.60 2.88 5 (DN125) 3.40 3.60 3.80 4.08 DN150 3.80 4.00 4.20 4.48 6 3.90 4.10 4.30 4.58 DN200 4.70 4.90 5.10 5.38 8 4.80 5.00 5.20 5.48 10 5.60 5.80 6.00 6.28 12 - 6.36 6.56 6.84 FIG. AF035 cULus MAX SEISMIC LATERAL LOADS: DIMENSIONS (IN) • LOADS (LBS) Service Brace Max Seismic Brace Load Specialty* Schedule 10 Schedule 40 Pipe Size Pipe Size 1-4 2765 (DN25 - DNlOO) 1-2 (0N25-DN50) 2765 2765 5-10 (DN1 25 - DN200) - 12 11/4 2 3740 3740 NPS Brace Pipe Dimensions per ASTM A53 Sch. 40, ASTM Al 06 Sch. 40, or equivalent. NPS Service Pipe Dimensions per ASTM A53, ASTM Al 06 or equivalent. DN Service Pipe Dimensions per KS D 3507/3537 or equivalent listed with Sch. 10 loads. DN Service Pipe Dimensions per KS D 3562 Sch. 40 or Equivalent listed with Sch. 40 loads. DN Brace Pipe Dimensions per KS D 3562 Sch. 40 or equivalent. * Specialty pipes are commonly referred to as Sch. 7 and Flow Pipe. Please visit the UL listing on the UL website for a complete list of listed specialty pipes. PH-3.19 47con. SEISMIC BRACES ®NVIL Fig. AF03 5 (Formerly Afcon Fig. 035) Model K Brace Clamp (cont.) FIG. AF035 FM MAX SEISMIC LATERAL ASD LOADS***: DIMENSIONS (IN) . LOADS (LBS) • ANGLES (DEGREES) Service Brace Pipe Max Seismic Brace Load at Brace Pipe Angle** 30-44 45-59 60-74 75-90 Pipe Size Pipe Size Schedule 1 - 11/2 LW* _ Sch. 40 1680 2380 2920 3250 (DN25-DN40) 1 2 2-3 (DN50 - DN80) LW* - Sch. 40 1800 2550 3120 3490 (DN25 - DN50) 4 LW* _ Sch. 40 (DN1 00) 1370 1930 2370 2640 5-8 Sch. 10 — Sch. 40 (DN125 - DN200) 730 1040 1270 1420 NPS Brace Pipe Dimensions per ASTM A53 Sch. 40, ASTM A106 Sch. 40, or equivalent. NPS Service Pipe Dimensions per ASTM A53, ASTM Al 06 or equivalent. DN Service Pipe Dimensions per EN 10220, GB/I 8163, or equivalent listed with LW loads. DN Service Pipe Dimensions per GB/I 3091, GB/I 3092, EN1 0255M, EN1 0255H, KS D 3507/3537, or equivalent listed with Sch. 10 loads. DN Service Pipe Dimensions per JIS G3452, KS D 3562 Sch. 40 or equivalent listed with Sch. 40 Loads. DN Brace Pipe Dimensions per GB/I 3091, EN1 0255H, AS G3454 Sch. 40, KS D 3562 Sch. 40, or equivalent. * Load Rating for LW above refers to FM Approved Lightwall pipe, commonly referred to as Sch. 7 and Flow Pipe. See FM Approval Guide for approved Lightwall pipe. ** Brace Pipe Angles are determined from vertical. The allowable FM approved capacity of brace subassemblies are listed in Allowable Stress Design (ASD). For Load Resistance Factor Design (LRFD) capacities, the above values will need to be mulitplied by 1.5. PH-3.19 SAMMYS FOR CONCRETE Easy two step process (Drill hole & drive Sammys concrete anchor). 1/7 pre-drilled pilot hole required. Concrete Installation Tool available for a one tool installation process. Made in the U.S.A. Wa7chaiñdeoderncj,tratiønat = www.itwbuildex.com #14 Black 1/4' 8058957 CST 200 5/16 x 1-3/4' 2400 25 125 Nut Driver <> 3/8 8059957 CST 20 5/16x13/4 2400 1475 25 125 Pa10 #l4SWRed 8145925 CST 20-SS - 5/16x1-3/4 2400 25 125 Nut Driver { 1/2 8060925 CST2 5/16x1-3/4 2400 25 125 Part#8114910 * Tested in 3000 PSI concrete !HORRiZONTA #14SW Red Nut Driver Part # 8114910 'Easy two step process (Drill hole & drive Sammys q - concrete anchor). - CO W pre-drilled pilot hole required. 'v - Concrete Installation Tool available for a one tool oP installation process. , 0DV 'Made in the U.S.A. WatthO vkieo uonoonsnoPon\ .www.ffwbulldex.comJ 114" 8062957 SWC 200 5/16x 1-3/4' 2450 25 125 3/8" 8061957 SWC2O 5116x1-3/4" 2450 1475 25 125 'Tested in 3000 PSI concrete Afft SPECIAL NUT DRIVER SYSTEM: The nut drivers were designed with a unique spin-off feature which provides a fast and safe installation each time. When the face of the driver comes into contact with the material you are installing into, continue drilling until nut driver spins kv MADE IN U.S.A free. Installation is then complete. Warranty requires the use of the appropriate nut driver for installations. 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5.1 Product Description 3.3.5.1 Product Description 3.3.5.2 Material Specifications 3.3.5.3 Technical Data 3.3.5.4 Installation Instructions 3.3.5.5 Ordering Information Listinos/Aoorovals ICC-ES (International Code Council) ESR-3027 (Cracked & Uncracked Concrete) FM Approved IN <~> , -- APPROVED Independent Code Evaluation IBC® / IRC® 2009 (AC 193/ ACI 355.2) IBC®/ IRC®2006(AC 193/ ACI 355.2) IBC® / IRC®2003 (AC 193/ ACI 355.2) Hilti KWIK HUS-EZ I (KH-EZ I) anchors are comprised of a body with an internally threaded hex washer head. The anchor is manufactured from carbon steel and is heat treated. It has a minimum 0.0003 inch (8 pm) zinc coating in accordance with DIN EN ISO 4042. The internally threaded head is larger than the diameter of the anchor and is formed with serrations on the underside. The anchor body is formed with threads running most of the length of the anchor body. The anchor is installed in a predrilled hole with a powered impact wrench or torque wrench. The anchor threads cut into the concrete on the sides of the hole and interlock with the base material during installation. Applicable base materials include normal-weight concrete, structural lightweight concrete and lightweight concrete over metal deck. Guide Specifications Screw anchors shall be KWIK HUS-EZ I as supplied by Hilti, Inc. Anchors shall be manufactured from heat treated carbon steel material, zinc plated to a minimum thickness of 8pm. Anchors shall be installed using a drill bit of same nominal diameter as anchor. Product Features Suitable for cracked and uncracked normal weight and lightweight concrete, and lightweight concrete over metal deck. Suitable for seismic and nonseismic loads. Quick and easy to install. Thread design enables quality setting and exceptional load values in wide variety of base material strengths. Anchor is fully removable Anchor size is same as drill bit size and uses standard ANSI B212.15 - 1994 drill bits. Suitable for reduced edge distances and spacing. 3.3.5.2 Material Specifications Hilti KWIK HUS-EZ I anchors are manufactured from carbon steel. The anchors are bright zinc plated to a minimum thickness of 8pm. 3.3.5.3 Technical Data The data contained in Tables 1-4 of this section have been evaluated in accordance with AC 193. For more detail, see ICC-ES ESR 3027. Figure 1 - KWIK HUS-EZ I anchor installation details Ws -----1. da L 1 F anch -, - h0 h corn dbI__:__. 2 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hlltl.com I en espanol 1-800-879-5000 I Huh (Canada) Corp. 1-800-363-4458 1 www.hllti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 Table 1 — KWIK HUS-EZ I (KH-EZ I) Design Guidelines For KWIK HUS-EZ I Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head d4 in. 1/4 or 3/8 Wrench Socket Size w in. 3/8 or 1/2 Nominal Diameter d in. 1/4 Drill Bit Diameter dbh in. 1/4 Maximum Installation Torque ft-lbf 18 Maximum Impact Wrench Torque Rating' ft-lbf 114 137 Minimum Nominal Embedment Depth h,, in. 15/8 21/2 Minimum Hole Depth h in. 2 27/8 Critical Edge Distance2 c 5 in. 2.00 2.78 Minimum Spacing at Critical Edge Distance in. 1.50 Minimum Edge Distance C.Ins in. 1.50 Minimum Spacing at Minimum Edge Distance s,5 in. 3.0 Minimum Concrete Thickness hmn in. 3.25 4.125 Anchor Category 3 1 Steel Strength in Tension (ACI 318 D.5.2) Tension Resistance of Steel N lb. 6,070 Reduction Factor for Steel Strength (t - 0.65 Concrete Breakout Strength in Tension (ACI 318 D.5.2) Effective Embedment Depth h ef in. 1.18 j 1.92 Effectiveness Factor - Uncracked Concrete K - 24 Effectiveness Factor - Cracked Concrete K. - 17 Modification Factor for cracked and uncracked concrete (4) - 1 Reduction Factor for Concrete Breakout Strength 0. - 0.45 0.65 Pullout Strength In Tension (ACI 318 D.5.3) Characteristic pullout strength, uncracked concrete (2500 psi) lb 13056 2358 Characteristic pullout strength, cracked concrete NP'a lb 6676 1166 Reduction Factor for pullout strength Op - 0.45 0.65 Characteristic Pullout Strength, Seismic (2500 psi) N8ACI lb 5348 1166 Reduction Factor for pullout strength 0.1 - 0.45 0.65 Values for Installation In the underside of Concrete-Filled Profile Steel Deck Assemblies2 Pullout Resistance, (uncracked concrete) - Lower Flute lb 12108 18759 Pullout Resistance, (uncracked concrete) - Upper Flute lb 14908 19609 Pullout Resistance, (cracked concrete and seismic loads) - Lower Flute N lb 6208 9309 Pullout Resistance, (cracked concrete and seismic loads) - Upper Flute Npdcr lb 7608 9758 1 The data presented in this table is to be used in conjunction with the design criteria of ACI 318 Appendix D. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. See Figure 2. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. T,,,,,_,applies to installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, and minimum spacing distance, s, or may be derived by linear interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 2,500 psi may be Increased by multiplying the value in the table by (fc/2,500)3 7 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value in the table by (f'c/2,500)°- 8 The characteristic pullout resistance for concrete compressive strengths greater than 3,000 psi may be increased by multiplying the value in the table by (f'c,,000)0 9 The characteristic pullout for concrete compressive strengths greater than 2,500 psi may be increased by multiplying the value In the table by (fc/2,500)05 l-titti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I en espanol 1.800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hlltl.ca I Anchor Fastening Technical Guide 2011 3 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor Table 2 - Calculated ACI 318-08 Appendix D Strength Design Capacity for Single anchor in Tension 1,4A6.7 Normal Weight Concrete LWCOMD Internally Nominal 2500 psi' 4000 psi 3000 psi2 Anchor Size Threaded Embedment Uncracked Cracked (in.) Head (in.) Depth (in.) Uncracked Cracked Seismic Uncracked Cracked Seismic Concrete Concrete Lower Upper Lower Upper Concrete Concrete Concrete Concrete Flute Flute Flute Flute 1/4 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4x1-5/8 3/8 1-5/8 587 300 240 675 346 277 545 670 280 342 1/4 2-1/2 1533 758 758 1940 958 958 1218 1275 605 634 1/4x2-1/2 3/8 2-1/2 1533 758 758 1940 1 958 958 1218 1275 605 634 1 Values for other strengths can be calculated per (fc12500)°3 for 1-5/8 embedment and (f'c/2500)°5 for 2-1/2' embedment 2 Values for other strength can be calculated per (fcJ3000)° for 1-5/8 embedment and (f'c/8000)°5 for 2-1/2" embedment 3 Based on single anchor with edge and spacing values greater than those given as critical values in Table 1. 4 Based on lower value of concrete breakout or pullout strength 5 These loads are factored resistance loads in accordance with Chapter 9 of ACI 318-08 (ONe). 6 Interpolation of values for other embedments is not permitted 7 Minimum concrete thickness and edge distance must comply with Table 1. Table 3- KWIK HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Illustrative Purposes Internal Thread Diameter Nominal Anchor Diameter Embedment Depth, h Effective Embedment Depth, he Allowable Tension Load of Head (in.) (in.) (in.) (mm) (in.) (mm) lb(kN) 1-5/8(41) 1.18(30) 470(2.1) 1/40r3/8 1/4 2-1/2(64) 1.92 (49) 1340(6.0) For SI: 1 inch = 25.4 mm, 1 lbf = 4.45 N. 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.2D + 1.6L. 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 = 4,000 psi (27.6 MPa) (normal weight concrete). 7 ;i=c2:c,e, see Table 1. 8 hh=,, see Table 1. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 D.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) + 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Figure 2-Installation of KWIK HUS-EZ I (KH-EZ I) in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Mn 3/4,, Structural Sand - Lightweight concrete or normal - . weight concrete over steel deck (minimum 3,000 psi) co d C., Mm. No. 20 gauge steel deck 1 Anchors may be placed in the upper or lower flute of the steel deck profile provided the minimum concrete cover above the drilled hole is satisfied. Anchors in the lower flute may be installed with a maximum 1-inch offset in either direction from the center of the flute. The offset distance may be increased proportionally for profiles with lower flute widths greater than those shown provided the minimum lower flute edge distance is also satisfied. 4 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hiltl (Canada) Corp. 1-800-363-4458 1 www.hilti.ca I Anchor Fastening Technical Guide 2011 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 Table 4 - KWIK HUS EZ I (KH-EZ I) Allowable Stress Design Tension Values for Installations in Soffit of Concrete Over Steel Deck Floor and Roof Assemblies Internal Thread Diameter of Head (in.) Nominal Anchor Diameter (in.) Embedment Depth (in.) (mm) Effective Embedment Depth (in.) (mm) Allowable Tension Load lb (kN) Upper Flute Lower Flute 1/40r3/8 1/4 1-5/8(41) 1.18(30) 466 (2.1) 378(1.7) 2-1/2(64) 1.92 (49) 885 (3.9) 846 (3.7) For SI: 1 inch = 25.4 mm, 1 Ibf = 4.45 N. 1 Single anchor with static tension load only. 2 Concrete determined to remain uncracked for the life of the anchorage. 3 Load combinations are taken from ACI 318 Section 9.2 (no seismic loading). 4 40% dead load and 60% live load, controlling load combination 1.21) + 1.6L. 5 Calculation of weighted average for conversion factor a = 1.2(0.4) + 1.6(0.6) = 1.44. 6 f' 3,000 psi (27.6 MPa) eight weight concrete). 7 cei=co.c, see Table 1. 8 h2h,, see Table 1. 9 Values are for Condition B where supplementary reinforcement in accordance with ACI 318 0.4.4 is not provided. 10 Allowable Tension Load = factored Load (Lesser of N or Concrete Breakout from Table 1) + 1.44 11 Values are for single anchors installed without influence of base material edge distance or adjacent anchors. Table 5 - Kwik HUS-EZ I (KH-EZ) Tested Load Values for FM Approval for Automatic Sprinkler Systems Hanger Rod Size an Screw Length FM Test Load FM Maximum Pipe Diameter (in.) Tension lb (kN)) (in) 15/8 3/8 1475 (6.6) 4 21/2 1 Tested in accordance with FM Approval Standard for Pipe Hanger Components for Automatic Sprinklers Systems Class Numbers 1951, 1952 and 1953. Table 6 - Kwik HUS-EZ I (KH-EZ I) Allowable Stress Design Values for Installations into Hollow Core Concrete Panels'-2 Hanger Rod Size (in.) Min. Effective Embedment h (in.) Allowable Load Ultimate Load Tension lb (kN) Shear lb (kN)4'5 Tension lb (kN) Shear lb (kN)45 1/4 1 3/8 455 (2.0) 485(2.2) 1810 (8.1) I 1,930(8.6) 3/8 755(3.4) I I 3,025 (13.5) The Admissible Anchor Location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core plank supplier to confirm Admissible Anchor Location. Minimum compressive strength of prestressed concrete Is 7,000 psi. Published ultimate loads represent the average results conducted in local base materials. Due to variations in materials and dimensionl configurations, on-site testing is required to determine the actual performance. Allowable loads calculated with a 4:1 factor of safety. The bottom of the shear plane adjacent to the top of the coupler. Shear values controlled by the steel strength of ASTM A193, Grade B7 (mm. tensile strength 125 ks screws used to fasten the shear fixturing. Shear values should consider the screw or threaded rod strength. Figure 3— Installation of KWIK HUS—EZ I (KH-EZ I) in Hollow Core Concrete 3.3.5.4 Installation Instructions Use the installation instructions that are including with the Kwik HUS-EZ I packaging box. To obtain a digital copy of the Installation Instructions, Visit www.us.hilti.com, www.hilti.ca or contact Hilti Technical Support. Hilti, Inc. (U5) 1-800.879.8000 1 www.us.hlltl.com I an español 1-800.879-5000 1 Hilti (Canada) Corp. 1-800.363.4458 1 www.hlltl.ca I Anchor Fastening Technical Guide 2011 5 3.3.5 KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor The data below is developed from testing performed in accordance with ACI 355.2. It is intended for applications designed according to GSA A23.3-04 Update No. 3 (August 2009) Design Of Concrete Structures Annex 0 and is generally suitable for the conditions described in the introduction of Annex D. Table 7- KWIK HUS-EZ I (KH-EZ I) Design Guidelines For KWIK HUS-EZ I Values for Normal Weight and Lightweight Concrete Characteristic Symbol Units Value Internal Thread Diameter of Head in. 1/4 or 3/8 Wrench Socket Size in. 3/8 or 1/2 Nominal Diameter d in. 1/4 Drill Bit Diameter cibit in. 1/4 Maximum Installation Torque TM ft-lbf(Nm) 18(24) Maximum Impact Wrench Torque Rating3 ft-lbf (Nm) 114 (154) 137 (186) Minimum Nominal Embedment Depth h mm 41 1 64 Concrete material resistance factor 41 - 0.65 Steel material resistance factor l - 0.85 Ultimate Strength of anchor steel f MPa 924 Effective cross-sectional area of anchor A mm2 29.0 Minimum Hole Depth h 10 mm 51 1 73 Minimum Spacing at Critical Edge Distance mm 38 Minimum Edge Distance c,In 5 mm 38 Minimum Spacing at Minimum Edge Distance s n.,mm 76 Minimum Concrete Thickness h. mm 83 105 Anchor Category 3 1 Steel Strength in Tension (CSA A23.3 D.6.1) Factored Steel Resistance in Tension N, kN 15.9 Reduction Factor for Steel Strength R - 0.70 Concrete Breakout Strength In Tension (CSA A23.3 D.6.2) Effective Embedment Depth het mm 30 49 Critical Edge Distance' c 5 mm 51 71 Effectiveness Factor - Uncracked Concrete - 10 Effectiveness Factor - Cracked Concrete K - 7 Modification Factor for cracked and uncracked concrete LiJc N - 1.4 Reduction Factor for Concrete Breakout Strength R - 0.70 1.00 Pullout Strength in Tension - Non Seismic Applications (CSA A23.3 D.6.3) Factored Pullout Resistance, uncracked concrete (17.23 MPa) Npr,uwr kN 2.66 6.8 Factored Pullout Resistance, cracked concrete (17.23 MPa) N cr kN 1,36 3,47 Concrete Resistance Factor for pullout strength - 0.65 Factored Pullout Strength, Seismic (17.23 MPa) N Meg kN 1.18 1 3,47 Concrete Resistance Factor for pullout strength 0csels - 0.65 Values for Installation in the underside of Concrete-Filled Profile Steel Deck Assemblies2 Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Lower Flute N dk kN 2.48 5,49 Factored Pullout Resistance, (uncracked concrete 20.68 MPa) - Upper Flute N dkU kN 3.08 579 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Lower Flute N4 ka kN 1.38 2.7 Factored Pullout Resistance, (cracked concrete and seismic loads 20.68 MPa) - Upper Flute N d kN 1,58 2.8 1 The data presented in this table is to be used in conjunction with the design criteria of CSA A23.3-04. 2 For installations through the soffit of steel deck into concrete, anchors installed in the lower flute may be installed with a maximum one inch offset in either direction from the center of the flute. 3 Because of variability in measurement procedures, the published torque of an impact tool may not correlate properly with the above setting torques. Over-torquing can damage the anchor and/or reduce its holding capacity. 4 applies to Installations using a calibrated torque wrench. 5 Additional combinations for minimum edge distance, c, and minimum spacing distance, may be derived by linear Interpolation between the given boundary values. 6 The characteristic pullout resistance for concrete compressive strengths greater than 17.23 MPa may be increased by multiplying the value in the table by (fc/1 7.23)° 7 The characteristic pullout for concrete compressive strengths greater than 17.23MPa may be increased by multiplying the value in the table by (fc/1 7.23)° 8 The characteristic pullout resistance for concrete compressive strengths greater than 20.68 We may be increased by multiplying the value in the table by (fci20.68)°-3 9 The characteristic pullout for concrete compressive strengths greater than 20.68 MPa may be Increased by multiplying the value in the table by (fc20.68)05 6 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hilti.com I an espanol 1-800-879-5000 1 Hilti (Canada) Corp. 1-800.363-4458 1 www.hlltica I Anchor Fastening Technical Guide 2011 Mechanical Anchoring Systems KWIK HUS-EZ I (KH-EZ I) Carbon Steel Screw Anchor 3.3.5 3.3.5.6 Ordering Information Order Information Internal Thread Internal Thread Hole Minimum city Description Diameter Length Diameter Embedment (pcs)/ Box KH-EZ 1/4"xl-5/8" 11/4" 1/4 3/8 1/4' 1-5/8 100 KH-EZ 1/4"x2-1/2" 11/4" 1/4" 3/8' 1/4' 2-1/2' 100 KH-EZ 1/4"xl-5/8" 13/8" 3/8" 7/16" 1/4" 1-5/8" 100 KH-EZ 1/4"x2-1/2" 13/8" 3/8" 7/16" 1/4' 2-1/2" 100 Hilti, Inc. (US) 1-800-879-8000 1 www.us.hlltl.com I en español 1-800-879-5000 1 Hilti (Canada) Corp. 1-800-363-4458 1 www.hllti.ca I Anchor Fastening Technical Guide 2011 7 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10(250mm) Voltages Available: 24VAC I2OVAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note I) -40° to 150°F (40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Notes: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. ULC only applies to MBA DC bells. Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6(150) 12VDC MBA-6-12 1750070 .12A 85 76 8(200) 12VDC MBA-8-12 1750080 .12A 90 77 10 (250) 12VDC MBA-10-12 1750060 .12A 92 78 6(150) 24VDC MBA-6-24 1750100 .06A 87 77 8(200) 24VDC MBA-8-24 1750110 .06A 91 79 10(250) 24VDC MBA-10-24 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10 (250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10 (250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. I AWARNING I In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-l. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 1 OF 2 01/13 Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2 conduit entrance 3 3/8" 5" 86 (127) (86) 4 1/4" (158) DWGII 776.2 (E)POTTER BELLS The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches (mm) Fig. 1 Wiring (rear view) Fig. 3 A.C. BELLS WHITE (IN) WHITE T PANEL OR FROM CONTROL CBLkCK(10OLUTT)1 PRECEDING BELL BLACK (IN) CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE WAND OUT LEADS AS SHOWN. NOTES: I. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL 2. END-OF-LINE RESISTOR IS NOT REQUIRED ONAC HELLS. 2 11/16" (68) DSVG# 776-I DWO# 176-3 Installation The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. Remove the gong. Connect wiring (see Fig. 3). Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). AWARNING Failure to install striker down will prevent bell from operating. PRINTED IN USA MFG. #5400776 - REV Y-1 PAGE 2 OF 2 01/13 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-0328:0119 Page 1 of I CATEGORY: 7135--AUDIBLE DEVICES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillW©pottersignal.com DESIGN: Models 513624-153075, SB624-75110, PBA246, PBA248, PBA2410, PBAI206, PBAI208, PBAI2010, *PBD126 *PBD..128 *pBD1210 *pBD246 *PBD..248 * PBD-2410 vibrating bells. Suitable for outdoor use when used with Model BBK-1 backbox. Models are AC or DC powered and available in 6", 8" and 10'. Models MBA-6, -8 and -10 bells, suitable for outdoor use when used with Model BBX-1 backbox. Refer to listee's data sheet for detailed product description and operational considerations. RATING: PBA-246, -248, -2410: 24 VAC PBA-1206, -1208, -12010: 120 VAC MBA-6, -8, -10: 12 or 24 VDC *PBD126 -128, -1210: 12VDC, .12A *PBD246 -248, -2410: 24VDC, .06A INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. If this appliance is required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition, the appliance must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. *Revision 01-31-2017 der, This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division VSG (DPOTTER LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD U.S. Pat. No. 3921989, Canadian Pat. No. 1009680 Other Patents Pending, Potter Electric, Rd., 1990 General Information The Model VSG is a flexible vane type of waterfiow switch for use in wet pipe water mist systems where a low flow for alarm is required. It is designed for installation in sections of 2 to 4 inch (50mm to 100mm) stainless steel or brass pipe with wall thickness in accordance with the above specifications (see "Nominal OD and Wall Thickness"). The unit may also be used as a sectional waterfiow detector on large systems. The unit contains an output relay and an adjustable electronic retard. The relay is actuated when aflow of 3 gallons per minute (11,4 LPM) or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Enclosure The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. Afield installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC, and CSFM Listed Service Pressure: Up to 450 P51 (31 BAR) Flow Required for Alarm: 3.0 GPM (11,4 LPM) Maximum Surge: 18 FPS (5,5 m/s) Power Requirements: STANDBY: lOma at 120V AC or 1.5ma at 24V AC/DC ALARM: 40rna at 120V AC or 3 5m at 24V AC/DC Contact Ratings: DPDT (Form C) 2 Amps at 0-30VDC or 0-125VAC resistive Conduit Entrances: 2 knockouts provided for 1/2' conduit Environmental Specifications: Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. NEMA 4 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40°F/120°F, 4,5°C/49°C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Nominal OD and Wall Thickness: (60,3mm OD), 3,9mm to 4,5mm wall 2 1/2" (73,0mm OD), 4,8mm to 5,2mm wall 2 1/2" (76,1mm OD), 4,3mm to 4,7mm wall (88,9mm OD), 5,0mm to 5,6mm wall (114,3mm OD), 5,4mm to 6,4mm wall Service use: Water mist systems where low flow for alarm is required. Optional: Cover Tamper Switch Kit, Stock No. 0090018 Installation See Fig. 1 These devices may be mounted on a horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" (15cm) of a fitting which changes the direction of the waterfiow or within 24" (60cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" +1/8" -1/16" (32mm ± 2mm). The 3" (80mm) and 4" (100mm) devices require a hole with a diameter of 2" ± 1/8" (50mm ± 2mm). Clean the inside of the pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterfiow. Install the saddle strap and tighten nuts alternately to an eventual 20 ft-lbs. (27 n-m) of torque. See Fig. I. The vane must not rub the inside of the pipe or bind in any way. Potter Electric Signal Company .2081 Craig Road, St. Louis, MO, 631464161 • Phone: 800-325-3936/Canada 888-882-1833' www.pottersignal.com PRINTED IN USA MFG. #5400999 - REV M PAGE 1 OF 2 5/08 TO INSTAUL, DRILL HOLE AS INDICATED. PIPE SIZE HOLE SIZE 2 to 2-t/2 (50 to (33mm ± 2mm) 30 to 4 2 ± t/8 00 to 100mm) (50mm A 2mm) VSG (E)POTTER LOW FLOW RATE VANE TYPE WATERFLOW The Symbol of Protection SWITCH WITH ELECTRONIC RETARD Retard Adjustment Fig. 1 The retard time is selected by turning the appropriate switches to the off position. Example: For 45 seconds turn switches 1, 2 and 3 to the off position. Approximate time is as follows: Switch Off Time in Sec. 1thru80n 0 1 15 1&2 30 1,2,&3 45 1,2,3,&4 60 l,2,3,4,&5 75 1,2,3,4,5,&6 90 7 not used 8 not used TIGHTEN NUTS ALTERNATELY TO AN EVENTUAL 20 FT-LBS. (27 n-rn) OF TORQUE I4OUNT ON PIPE SO 01180W ON SADDLE POINTS IN DIRECTION OF WAIERFLOW ROLL PADDLE IN OPPS1JPICBON OF I782_30 Fig. 2 Typical Electrical Connections LINE 0 1 B lov ELL I I AC I NEUTRAL FO 120~ 24V COM. ORD AUX. CONTACTS HIGH VOLTAGE RELAY ACTION 24V BELL 11 1 N.C.CON NC 01.050 4/6 WIRE CONTROL PANEL CIRCUIT DETECTOR CIRCUIT END OF LINE RESISTOR OR I20024v CON. N.O.COU.N.CJ FROM PANEL RETURN TO CONTROL PANEL 24V DC POWER AUX 0 ,[IV O 00-01 I 24V DC RELAY 24V COM NO. CCNN.C. SHOWN ENERGIZED ON tcN CONTACT GNU NOTE BASE MUST BE CONNECTED TO A GOOD EARTH GROUND. LOW VOLTAGE AC LOW VOLTAGE DC OWO. 4985-1 Fig. 3 Switch Terminal Connections Clamping Plate Terminal . "'Co OWlS 013-3 I A CAUTION I When supervised circuits are used the following must be observed: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. Application Warning! Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterfiow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. Testing: The operation of the waterfiow switch and the associated alarms is to be tested upon completion of the installation and periodically thereafter in accordance with the applicable NFPA standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). A minimum flow of 3 GPM (11,4 LPM) is required to activate this device. PRINTED IN USA MFG. #5400999 - REV M PAGE 2 OF 2 5/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7770-0328:0010 Page 1 of 1 CATEGORY: 7770 -- VALVES/SWITCHES LISTEE: Potter Electric Signal Co1609 Park 370 Place, Hazelwood, 63042 United States Contact: Bill Witherspoon (314) 595-6900 Fax (314) 595-6999 Email: BillWpottersignal.com DESIGN: Supervisory switches listed below to monitor pressure, OS&Y, gate, globe/gate, Ply, tank temperature or water level valves. Refer to listees data sheet for detailed product description and operational considerations. HLS-B WLS-W PS-120A OSYSU-2 PTS-B OSYSU-1 PlVS-B TTS-S WLS PTS-C RBVS *P515 WLS-S PS-40A OSYS-B PMS GVS PCVS-1 TTS-W PCVS-2 PS4O PS12O *PS25 INSTALLATION: In accordance with listees printed instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and FM or UL label. APPROVAL: Listed as sprinkler system supervisory switches. NOTE: Formerly 7738-0328:010 *Revision 09-07-2016 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not :.!Z. an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2018 Listing Expires June 30, 2019 Authorized By: DAVID CASTILLO, Program Coordinator Fire Engineering Division FireLock® Butterfly Valve Aitauii Style 705 with Weatherproof Actuator 10.81 1.0 PRODUCT DESCRIPTION Available Sizes: 2 - 12/50 - 300 mm cULus Listed, LPCB Listed, FM and VdS Approved for service up to 300 psi/2068 kPa /20 bar. Designed for fire protection services only. Features a weatherproof actuator housing Approved for indoor and outdoor use. Actuation options: Hand wheel (2 - 12/50 - 300 mm) Exclusively for use with pipe and Victaulic products which feature ends formed with the Victaulic Original Groove System (OGS) groove profile (see section 7.0 for Reference Materials). 2.0 CERTIFICATION/LISTINGS c®us LISTED G410001 104i104 NOTES Refer to Victaulic submittal publication 10.01 for details ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic company. All rights reserved. taullie 1 victaulic.com 2.1 CERTIFICATION/LISTINGS Approval/Listing Service Pressures Series 705 Butterfly Valve cULus FM Vds LPCB Size 50 up to 300psi/2068kPa n/a up to 300psi/2068kPa up to 300psi/2068kPa 2/2 65 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 76.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 80 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 1 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 125 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 1 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 200 up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10 250 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12 300 up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 3.0 SPECIFICATIONS - MATERIAL • Body: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 End Face, 2 - 6"/50 150 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Seal Retainer, 8 - 12"I200 - 300 mm: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 Body Coating: Black alkyd enamel Disc: Ductile Iron conforming to ASTM A-536, Grade 65-45-12, with electroless nickel coating conforming to ASTM B-733 Seat: Grade "E" EPDM Stems: 416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge: C36000 brass Bearings: Stainless steel with TEE lining Stem Seals: EPDM Stem Retaining Ring: Carbon steel Actuator: 0 2-8/50-200 mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing O 10 - 12/250 - 300 mm: Steel worm and cast iron quadrant gear, in a cast iron housing 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic company. All rights reserved. victaulic.com 2 \J(taUIiC victauliccom 4.0 DIMENSIONS Style 705 Size Dimensions Actual Outside E to E DIA Nominal Diameter A B C D E F G H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.375 4.25 2.28 6.41 - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.875 3.77 2.28 7.54 - 4.00 4.22 4.50 1.77 73 73.0 95.8 57.9 1 191.5 101.6 107.2 114.3 45.0 3.000 377 228 754 400 422 450 177 761 mm 76.1 95.8 57.9 191.5 - 101.6 107.2 114.3 45.0 3 3.500 3.77 2.53 7.79 - - 4.50 4.22 4.50 1.77 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 4.250 463 288 881 550 422 450 220 08mm 108.0 117.6 73.2 223.8 - 1 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 - - 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 588 335 1088 656 619 630 258 133mm 133.0 149.4 85.1 276.4 - - 166.6 157.2 160.0 1 65.5 5.500 5.88 3.35 10.88 6.56 6.19 6.30 2.58 . mm 139.7 149.4 85.1 276.4 - - 166.6 157.2 160.0 65.6 5 5.563 588 335 1088 - 656 619 630 258 141.3 141.3 149.4 85.1 276.4 166.6 157.2 160.0 65.5 6.250 5.88 3.84 11.38 0.41 7.52 6.19 6.30 2.58 59mm 159.0 149.4 97.5 289.1 - 10.4 191.0 157.2 160.0 65.5 6.500 5.88 3.84 11.38 0.41 7.52 6.19 6.30 2.58 65.1 mm 165.1 149.4 97.5 289.1 - 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.750 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 273 273.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 - 12 12.750 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 - 323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 NOTE Optional 1/2 /15mm tap available. Contact Victaulic ford eta ils. 10.81 5662 Rev C Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com A-Cta-ulicr victaulic.com p 5.0 PERFORMANCE Style 705 The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/rn inches inches of pipe 2 2.375 6 50 60.3 1.8 2½ 2.875 6 65 73.0 1.8 761 mm 3.000 168 76.1 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 108 mm 108 mm 284 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 37 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159m 159mm 14m 43 165.1 mm 6.500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic company. All rights reserved. victaulic.com 4 X,/aC__t:3_UIie victaulic.com 5.1 PERFORMANCE Style 705 Cv values for flow of water at +60°F/-t-160C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for C values Formulas for K5 values j\jD = 02 Where: = Q = Flow (GPM) AP = Pressure Drop (psi) Q = C, x JAP C= Flow Coefficient Q = K, Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches Cv mm mm 2 2.375 170 50 60.3 21/2 2.875 260 65 73.0 76.1 mm 3.000 76.1 260 3 3.500 440 80 88.9 4 4.500 820 100 114.3 108mm 108mm 820 5 5.563 1200 125 141.3 133 mm 133 mm 1200 139.7mm 35 1200 6 6.625 1800 150 168.3 159 mm 159 mm 1800 165.1 mm 6.500 1800 165.1 8 8.625 3400 200 219.1 10 10.750 5800 250 273.0 12 12.750 9000 300 323.9 Where: Q = Flow (m3/hr) AP = Pressure Drop (Bar) K, = Flow Coefficient Valve Size Full Open Actual Nominal Outside Size Diameter Flow Coefficient inches inches K, mm mm 2 2.375 147 50 60.3 21/2 2.875 225 65 73.0 76.1 mm 3.000 225 76.1 3 3.500 380 80 88.9 4 4.500 710 100 114.3 108mm 108mm 710 5 5.563 1040 125 141.3 133mm 133 mm 1040 139.7mm 5.500 1040 13 6 6.625 1560 150 168.3 159 mm 159 mm 1560 165.1 mm 6.500 1560 165.1 8 8.625 2940 200 219.1 10 10.750 5020 250 273.0 12 12.750 7790 300 323.9 10.81 5662 Rev G Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5 I I ~' Ar-_ t_: a -U1 i C victau!ic.com 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Switch and Wiring The supervisory switch contains two single pole, double throw, pre-wired switches. Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC 0.25 amps @ 250 VDC Switches supervise the valve in the OPEN" position. One switch has two #18 insulated wires per terminal, which permit complete supervision of leads (refer to diagrams and notes below). The second switch has one #18 insulated wire per terminal. This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve is installed. A #14 insulated ground lead (green) is provided. Switch #1 = Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch #2 = S2 Auxiliary switch that may be connected to auxiliary devices, per the authority having jurisdiction S, f Normally Closed: (2) Blue Common: (2) Yellow Normally Closed: Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe IS I 15115 JUNCTION BOX CONDUIT W NP CONDUITCONNECTIWS IRE NUTS FIRE ALARM TO END-OF-LINE RESISTOR, CONTROL PANEL OR NEST INDICATOR SUPERS1SORY CIRCUIT NO COM. SWITCH CONTACT RAT NO: IOU AT 125 AND S1 I 2SOVAC, 05A AT 125 VDC, 0.25 AT 250 VDC 52 BELL OR VOLTAGE SOURCE HORN Switch 1:2 leads per terminal Switch 2:1 teed per termlnel NOTES The above diagram shows a connection between the common terminal (yellow - Si and yellow-with-orange stripe - S2) and the normally closed terminal (blue - Si and blue-with-orange stripe —S2). In this example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open, the indicator light and alarm will go out, cap off any unused wires (e.g. brown with orange stripe). Only Si (two leads per terminal) may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70 (NEC). 10.81 5662 Rev G updated 08/2016 © 2016 Victaulic company. All rights reserved. victaulic.com 'd'tJIuuic• victaulic.com p 7.1 REFERENCE MATERIALS 10.01; Regulatory Approval Reference Guide 29.01; Terms and Conditions/Warranty 1-100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination an to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed Is alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any palest or other intellectual properly right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as recommendation for the use of such material, product, service, or design in the infringement of any patentor other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.81 5652 Rev C Updated 08/2016 © 2016 Victaulic Company. All rights reserved. victaulic.com JAi -C tau Iicr 300 psi UL/ULC Listed* Working Pressure: 400 WOO Installation Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication arrow that has been cast into the valve body. The most common installation allows for a 1/4" IPS nipple between the valve and the water supply being measured. This assures there will be ad- equate spacing for the sprin- kler system gauge from the riser. Use either PTFE Pipe Thread Sealing Tape or a suit- able pipe thread sealant such as PipeFit® Thread Sealant Paste with PTFE when in- stalling the valve. DO NOT OVERTIGHTEN THREADS. OVERTIGHTENING MAY CAUSE VALVE FAILURE. *UUULC Listed 2R97 Description The 1/4 IPS three-way female threaded valve is used to facili- tate the installation of sprinkler system pressure gauges. The valve provides for one inlet and two outlets. This design allows for replacement of the system gauge without shutting down the water supply to the sprinkler system. This design also allows Authoritys' Having Jurisdication to test system pressure with an additional gauge through the second outlet. (The second outlet is normally plugged during installation with a 1/4" IPS pipe plug.) Specifications Materials: Seat- Brass Body- Brass Handwheel - Iron Sizes: 1/4" IPS ©2003-2007 Fire Protection Products, Inc Fire Protection Products, Inc. ppr 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822 • 1 800 344-3775 fax • wwN.ppi.com mvadN wa u NETviJWiDiII Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve The AGF Model 1011 TESTANDRAIN® provides the test and express drain functions for wet fire sprinkler systems on multi-story installations requiring pressure relief (NFPA 13 and NFPA 13R). The Model 101 1A features a Model 7000 Pres- sure Relief Valve with drain pipe. The Model 1011 is available in a full range of sizes (3/4 ' to 2) with NPT connections (BSPT available). The Model 7000 Pressure Relief Valve (ULJFM) features a flushing handle and a 175 PSI factory rating (other pressure ratings available). Complies with NFPA 13 and NFPA 13R Requirements Compact, Single-Handle Ball Valve Tamper-Resistant Test Orifice and Sight Glasses 300 PSI rated. Specifiable orifice sizes: %' (2.8K), 7A6" (4.2K), ½" (5.6K), 17/32" (8.0K), 5/s" (11.2K, ELO), 3/4" (14.0K, ESFR), and K25 Relieves Excess System Pressure caused by Surges or Temperature Changes Shipped with Relief Valve and Bypass Drain Ports Plugged to Expedite Pressure Testing Locking Kit Available Repair kits are available for all TESTANDRAIN® valves. Kit includes: Adapter Gasket (1), Ball (1), Valve Seats (2), Stem Packing (1), and Stem Washer (1). Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90% and 105% of their rating. The valves are required to CLOSE at a pressure above 80% of that rating. The relief valve should be installed where it is easily accessible for maintenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational. A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. \ uayL@10 1&1 eW09930 iy SS-M1 011 A_V001 06/13 TESrNDRAINe is a registered trademark of AGF Manufacturing Inc. Model 1011 - Front View Model 1011 - Plan View Orifice Sizes 3/SM, 7A6, 1/20, 17/32" 5/811 ELO*, 3/4" ESFR*, and K25** Materials Handle................Steel Stem...................Rod Brass Ball ...................... C.P. Brass Body...................Bronze Valve Seat...........Impregnated Teflonm Indicator Plate .... Steel Relief Valve.........Bronze Bypass Fittings... Brass Bypass Tubing .... Nylobraid Approvals UL and ULC Listed: (EX4019 & EX4533) FM Approved d—W—P NYC-BSA No. 720-87-SM MADE IN U.S.A. 0 FOR IN UNMA USTED 11 U [E2U&H P nz% H Model I0I1A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve APPROVHI Factory Rated at 175 PSI with other setting available Dimensions SIZE A B C 13 E F G H 1/4 ' 79/16" 11h' 23,16" 3%" 3%" 113," 4A6" 63/8" (191 mm) (37.5 mm) (57 mm) (93 MM) (86 MM) (46 mm) (117 mm) (162.5 mm) 7906' 1½" 23A6" 35/8" 3%" 113A6" 49A6' 63,'" (191 mm) (37.5 mm) (57 mm) (93 mm) 1 (86 mm) (46 mm) (117 mm) (162.5 mm) 11/4" 715/16" 111,16' 29,16" 41/4" 35W 115A6" 59A6" 71h" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1½ 815/16" 113,16" 31/4" 51A6' 3/8" 25W 81/4" 107,/s" (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (27 mm 2" 815A6" 113/16" 31/4" 51A6" 3/8" 2%' 81/4 ' 10/8" (227 mm) (45 mm) (81.5 mm) (127 MI) (99 mm) (67 mm) 1 (207 mm) (274 mm) The Model 1011 provides the following... From the 2013 Edition of NFPA 13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, interior sectional or floor control valve(s) - & 8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter A.8.17.4.2 et Pipe System) test connection is permitted to terminate into a drain capable of accepting full flow.., using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler... Chapter 8.17.4.2.2 The test connection valve shall be accessible. Chapter 8.17.4.2.4 shall be permitted to be installed in any location.., downstream of the waterfiow alarm. Chapter 8.17.4.3.1 (Dry Pipe System) a trip test connection not less than 1" in diameter, terminating in a smooth bore corrosion-resistant orifice, to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection... with a shutoff valve and plug not less than 1", at least one of which shall be brass. Chapter 7.1.2 - a wet pipe system shall be provided with a listed relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3" A listed relief valve of not less than ½" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding rated pressure of the system. Chapter A.8.16.1.2.3 - consideration should be given to piping the discharge from the (pressure relief) valve DO Pla en rig AGF Manufacturing Inc. 100 Quaker Lane, Malvern, PA 19355 A Phone: 610-240-4900 Fax: 610-240-4906 www.testandrain.com "Available on 11/4 to 2 size units only • **Available on 11/2 and 2 size units only Job Name: Architect: Engineer: Contractor: L \\\N\A/PE POTTER ROEMER VALVES PRO. ANGLE HOSE VALVES Member of Morris Group lnternaIional° L... Model/Series No. 4060-4075 SERIES SPECIFICATIONS ANGLE VALVES FEMALE X MALE Cast brass valve with red hand wheel, Female N.P.T. inlet x male hose thread outlet. 300 psi DOUBLE FEMALE Cast brass valve with red hand wheel. Female N.P.T. inlet and outlet. 300 psi MODEL SELECTION VALVES Li 4060 1-1/2" Female x Male Angle Valve '4FM' Li 4065 2-1/2" Female x Male Angle Valve 4FM llio LI 4065-500 2-1/2" Female x Male Angle Valve 500 psi LJ4070 1-1/2" Double Female Angle Valve 4FM- Li 4075 2-1/2" Double Female Angle Valve 1FM' LI 4075-500 2-1/2" Double Female Angle Valve 500 psi OPTIONAL CAPS & FLANGES Li 4615 1-1/2" Cap w/ Chain Li 4625 2-1/2" Cap w/ Chain EJ 4711 1-1/2" Flange 3" O.D. Li 4712 2-1/2" Flange 6-1/4" O.D. c®uS <> AROM LISTED -'b— -77 * , MODEL 4065 (Shown) PRODUCT OPTIONS FINISHES: Li -B Polished Brass Li -C Rough Chrome Plated Li -D Polished Chrome Plated THREADS: Li N.S.T. Li Other VARIATIONS: Li Extended Stem Up to 24" Specify Li Rocker Lugs (Cap Models Only) Li -GRV Grooved Inlet (4065 Only) Call Potter Roamer - Fire Pro for current listings and POTTER ROEMER/FIRE PRO FIRE EQUIPMENT approvals. Dimensions are subject to manufacturer's tolerance and may change without notice. Potter Roamer- r ASSOCIATION ' ONFSA Headquarters: Also in: MANUFACTURERS P.O. Box 3527 New York (800) 526-4592 Fire Pro assumes no responsibility for use of void or - - superceded data. © Copyright Potter Roemer- Fire Pro, ru City of Industry, CA Chicago (800) 547-3473 potfcrroemer.com for most current specifications. [1 cIAS P E . Los Angeles Area Miami (866) 961-3473 Member of Moms G rou p Please visit ' -'." 91744 U.S.A. Atlanta (800) 762-0542 - - - -- - I ,*sresvi 800-366-3473 Dallas (866) 644-3473 40604015 SERIES Date: 10/20/15 NFP E5,**, •. - 626-855-4890 www.potterroemer.com \\\\\FlpE POTTER [ L OEMER VALVES PRO . I ANGLE HOSE VALVES Member of Morris Group lnternationalre L -- ------ - -- --- - - ------ Model/Series No. 4060-4075 SERIES MODEL DIMENSIONS Size Closed Open - A B C C D E 1-1/2 2-1/4 3-1/2 6-1/2 7-1/2 2-1/2 2 2-1/2 3-1/2 5 9-1/2 11-1/2 3-1/2 2-3/4 ALL DIMENSIONS IN INCHES MODEL 4060-4065 B 103,, (Open ...-.,-- 9" (Closed fsmil* -X Mato 1110011`1 31 MODEL 4065-GRV H- A - E Female X Female A MODEL 4070-4075 Call Potter Roomer - Fire Pro for current listings and - FIRE EQUIPMENT __ POTTER ROEMER/FIRE PRO approvals. Dimensions are subject to manufacturer's tolerance and may change without notice. Potter Roemer- MANUFACTURERS OIFSA Headquarters: Also in: Fire Pro assumes no responsibility for use of void or - ASSOCIATION P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roemer- Fire Pro, City of Industry, CA Chicago (800) 547-3473 Member of Mores Group International re Please visit p000erroemer.com for most current specifications. - - (] /%,AD - 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866) 961-3473 Dallas 644-3473 ' 800-366-3473 (866) 4060-4015 SERIES Date: 10/20/15 NFPA E" E'' 626-8554890 www.potterroemer.com L. -'- a 'I MODEL 5216 (Shown) PRODUCT OPTIONS FINISHES: U -D Polished Chrome Plated VARIATIONS: U -F Silicock Flange Plate with Silicock THREADS: U N.S.T. U Other_ LETTERING AVAILABLE: U STANDPIPE U DRY STANDPIPE U AUTO. SPKR. U AUTO. SPKR. STANDPIPE U Other \\J POTTEP CONNECTIONS (FDC) POEMER FIRE PRO. FLUSH 2,4&6WAY CLAPPER Member of Morris Group International INLET TYPE BODY INLET Model/Series No. 5100-5400 SERIES_J SPECIFICATIONS Cast brass or ductile iron body with drop clappers, type and size of outlet and number of inlets as selected by model number. Polished brass plate with lettering as selected. Polished brass double female snoots with rigid end 3" N.P.T. x 2-1/2" pin lug hose thread swivels, pin lug plugs and chains. Outlet location as selected by suffix letters. MODEL SELECTION TWO-WAY U 5104 Back Outlet U *5114 Back Outlet U *5116 Back Outlet lj 5124 Angle Outlet U *5134 Angle Outlet U *5136 Angle Outlet U 5144 End Outlet U *5154 End Outlet U *5156 End Outlet FOUR-WAY U 5206 Back Outlet U *5216 Back Outlet Ii *5226 Angle Outlet U *5236 Angle Outlet U 5246 End Outlet U *5256 End Outlet SIX-WAY U 5306 Back Outlet U 5308 Back Outlet U 5326 Angle Outlet U 5328 Angle Outlet U 5346 End Outlet U 5348 End Outlet FOUR-WAY SQUARE 5406 Back Outlet U *5416 Back Outlet U 5426 Angle Outlet U *5436 Angle Outlet NOTE: * = UL Listed Call Potter Roamer - Fire Pro for current listings and approvals. Dimensions are subject to manufacturer's tolerance and may change without notice. Potter Roamer- - - RE EQUIPM FI ENT MANUFACTURERS' YNFSA POTTER ROEMER/FIRE PRO Headquarters: Also in: Fire Pro assumes no responsibility for use of voider - - ASSOCIATION P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roamer- Fire Pro, city of Industry, CA Chicago (800) 547-3473 Member of Morris Group International '° Please visit 000erroeme pr.com for most current specifications..'",AS - - P E ' . O 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866) 961-3473 800-366-3473 Dallas (866) 644-3473 51005400 SERIES Date: 10/02/15 NFP \ '''' 626-855-4890 www.potterroemer.com A POTTER ROEMER CONNECTIONS (FDC) \\''w DflQ I FLUSH 2, 4 & 6 WAY CLAPPER \I I L.. fl INLET TYPE BODY INLET Member of Morris Group International'"L_. - Model/Series No. 5100-5400, SERIES MODEL DIMENSIONS OUTLET LOCATION No. Inlets Outlet Body Material Dimensions Back Model No. Angle Model No. End Model No. Size A I B C D I E Two-Way 5104 5124 5144 2 1 4 1 Brass 51/4 I 14 15 - I 71/2 *5114 *5134 *5154 2 1 4 1 Ductile Iron 51/4 I 14 1 15 - I 71/2 *5116 *5136 *5156 2 ] 6 Ductile Iron 73/4 I 14 15 - 71/2 Four-Way 5206 I *5226 5246 I 4 I 6 I Brass I 73/4 I 29 I 30 I - I 81/2 *5216 *5236 *5256 I 6 I Ductile Iron 73/4 29 I 30 I - I 81/2 Six-Way 5306 I 5326 I 5346 I 6 I 6 I Brass I 73/4 I 43 1 441/4 I - I 81/2 5308 I 5328 I 5348 I 6 8 Brass 1 93/4 I 43 1 441/4 I - I 81/2 Four-Way Square & 5406 I 5426 - I 4 I 6 I Brass 1 71/2 I 12 I - 83/4 I 8 *5416 I *5436 - I4 I 6 I Ductitle Iron I 71/2 12 I - I 83/4 I 8 NOTE: * = U/L Listed ALL DIMENSIONS IN INCHES Call Potter Roamer - Fire Pro for current listings and - FIRE EQUIPMENT POTTER ROEMERIFIRE PRO approvals Dimensions are subject to manufacturer's ASSOCIATION OtIFSA Headquarters: Also In: P.O. Box 3527 New York (800) 526-4592 Fire Pro assumes no responsibility for use of void or - ouperceded data. © Copyright Potter Roamer- Fire Pro, City of Industry, CA Chicago (800) 547-3473 tolerance and may change without notice. Potter Roamer- MANUFACTURERS' Member of Morris Group International Please visit 91744 U.S.A.Atlanta (800) 762-0542 - - potterroemercom for most current specifications. AS P E - Los Angeles Area Miami (866) 961-3473 9 800-366-3473 Dallas (866) 644-3473 51005400 SERIES Date: 10/02/15 WAX ""°'°""' 626-8554890 www.potterroemer.com Angle Outlet Others (Typ.) FOUR-WAY SQUARE BODY 44" 111.8cm 30" _______ 7&2cm F 5 -"-7" I_1 L 38.I cm 91. "- i-i 00 17.8 urn 22.9 cm L 16" (Horizontal) Top SUFFIX-HT Bottom SUFFIX- HB (Vertical) 0 SUFFIX -VR 0 Right Left o SUFFIX -VL LV\\F1PE POTTER - - Model/Series Nol CONNECTIONS (FDC) 5100-5400 FLUSH 2,4&6WAYCLAPPER flRO INLETTYPEBODYINLET SERIES Member of Morris Group lnternaIional° L.. . --------------------- - - - c • I. B .1 I B I I BI 1 7._ E Nipple ________ By "trnf~ -------Others Ix 1 0 1. .1 E Wall 7U 7U V WITH BACK OUTLET BODY 31/2 8.9 CM WITH END OUTLET BODY - (Horizontal) (Vertical) SUFFIX -H 1J)0 SUFFIX -V U (Horizontal) [D000) Left SUFFIX -HL (000cI Right SUFFIX -HR 3'. 7.6 cm Nipple By Others" (Typ.) (Vertical) Top SUFFIX SUFFIX -VT -yB Bottom IQJ WITH ANGLE OUTLET BODY Horizontal or Vertical PLATES Call Potter Roemer - Fire Pro for current listings and approvals. Dimensions are subject to manufacturer's tolerance and may change without notice. Potter Roemer- FIRE EQUIPMENT \.\\ MANUFACTURERS' ONFSA ,/ POTTER ROEM ER/F IRE PRO Headquarters: Also in: Fire Pro assumes no responsibility for use of void or - ASSOCIATION .... P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roemer- Fire Pro, City of Industry, CA Chicago (800) 547-3473 Member of Morris Group International"- Please visit - - pofterroemer.com for most current specrspecifications.ASPE€ 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866) 961-3473 800-366-3473 Dallas (866)644-3473 f"° 51005400 SERIES Date: 10/02/15 NFP 626-855-4890 Mpotterroemer.com FireLock® Check Valves Series 717 Check Valve Series 717H High Pressure Check Valve Series 717 Series 717 (21/2 - 3/65 —80 mm) (4— 12/100 —300 mm) 2 Series 717H High Pressure Check Valve (2— 3/50 —80 mm) 1.0 PRODUCT DESCRIPTION Available Sizes 2— 3'/DN50 - DN80 (Series 717H) 21/2 - 127DN50 - DN300 (Series 717) Pressure Class Up to 365 psi/2517 kPa/25 bar Working pressure dependent on size of pipe, valve size and approval requirements. Application Designed for use in Fire Protection systems. Prevents back flow. Single-disc mechanism incorporates a spring-assisted feature for non-slamming operation. Can be installed either vertically (flow upwards only) or horizontally. Valve body cast with arrow indicator to assist with proper valve orientation. Optional upstream and downstream pressure taps included on select sizes. See Section 3.0. Provided with grooved ends. Rated for ambient temperature use in fire protection systems. 2.0 CERTIFICATION/LISTINGS LPCB USHO NOTE Refer to Victaulic submittal publication 10.01 for details \,L taulic 10.08 ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. p System No. Location Spec Section Paragraph Submitted By Date Approved Date p victaulic.com 10.08 1479 Rev S updated 03/2017 0 2017 Victaulic company. All rights reserved. 1 j4tauiic victaulic.com 2.0 CERTIFICATION/LISTINGS (Continued) Approvals/Listings Size Approval/Listing Service Pressures Series 717H cULus FM LPCB Vds 2750 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 21/2"/65 mm 365 psi/2517 kPa 365 p51/2517 kPa 365 p51/2517 kPa 365 psi/2517 kPa 76.1 mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 365 p51/2517 kPa 3/80mm 365 psi/2517 kPa 365 psi/251 7 kPa 365 psi/251 7 kPa 365 p51/2517 kPa Size Approval/Listing Service Pressures Series 717 cULus FM LPCB Vds 21/2°/65 mm 250ps1/1725kPa n/a 365 psi/2517 kPa n/a 76.1 mm 250ps1/1725kPa n/a 365 psi/25i7kPa 16bar/232ps1 3780 mm 250 psi/1 725 kPa n/a 365 psi/2517 kPa 16bar/232 psi 4"/1 00mm 365 psi/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 16bar/232 psi 5/125mm 365 psi/2517 kPa 365 psi/2517 kPa 365 p51/2517 kPa n/a 139.7mm 365 psi/2517 kPa 365 p51/2517 kPa 365 psi/2517 kPa 16bar/232 psi 67150 mm 365 p51/2517 kPa 365 psi/2517 kPa 365 psi/2517 kPa 16bar/232 psi 165.1 mm 365p51/25i7kPa 365ps1/25i7kPa 365 psi/2517 kPa n/a 8/200mm 365 psi/2517 kPa 365 psi/2517 kPa 348 psi/2400 kPa 16bar/232 psi 10/250mm 250 psi/1 725 kPa 250 psi/1 725 kPa 1725 kPa/250 psi n/a 12/300mm 250 psi/1 725 kPa 250 psi/1 725 kPa 1725 kPa/250 psi n/a 10.08 1479 Rev S Updated 03/2017 Q 2017 Victaulic Company. All rights reserved. victaulic.com 0-or- X/ tauIicr uig'fiiilit' mm 3.0 SPECIFICATIONS - MATERIAL Body: 0 Ductile Iron conforming to ASTM A-536, Grade 65-45-12. Body Coating: O Series 717H Body: Black Paint O Series 717H Endface: Electroless Nickel conforming to ASTM B-733 0 Series 717 (2 112 - 3"/DN65 - DN80): PPS Coating Series 717 (4 - 127DN100 - DN300): Black Paint Body Seat: O Series 717H: Nitrile 0-ring installed into an Electroless Nickel plating conforming to ASTM B-733 O Series 717 (2 ½" - 3"/DN65 - DN80): PPS Coated Ductile Iron D Series 717 (4— 12"/DN100 - DN300): Ductile Iron with Electroless Nickel plating conforming to ASTM B-733 Disc Seal or Coating: (specify choice') Nitrile (Series 717H only) F1 EPDM NOT COMPATIBLE FOR PETROLEUM SERVICES. Discs: O Series 717H: CF8M Cast Stainless Steel O Series 717 (2½ - 37DN65 - DN80): Aluminum bronze with elastomer seal O Series 717 (4 - 12YDN100 - DN300): Elastomer encapsulated disc. Shaft: El Series 717H: Brass D Series 717 (2112 - 3/DN65 - DN80): Type 416 Stainless Steel Series 717 (4 - 12/DN100 - DN300): Type 316 Stainless Steel Spring: 0 Type 302/304 Stainless Steel Shaft Plug: U Series 717H: Carbon Steel Zinc Plated 0 Series 717: Carbon Steel Zinc Plated Pipe Plug: Series 717H: Carbon Steel Zinc Plated El Series 717: Carbon Steel Zinc Plated Optional Pressure Taps: E] Series 717H: Available on all sizes 0 Series 717: Available on sizes 4— 12/DN100 - DN300 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com C] Ac- ta uIic victaulic.com 4.0 DIMENSIONS Series 717 an Typical 2 ½ - 3/65 -80 mm A ½' NPT Upstream Drain 'If NPT Downstream Drain 2' NPT (Drain Optional) Typical 4-8/100-200 mm 0½' NPT Upstream Drain Q ½" NPT Downstream Drain Typical 10- 12/250 -300 mm Size Dimensions Weight Actual Outside E to E Approximate Nominal Diameter A B C D E J K P R (Each) inches inches inches inches inches inches inches inches inches inches inches lb mm mm mm mm mm mm mm mm mm mm mm kg 21/2 2.875 3.88 4.26 3.57 - - - - - - 3.6 65 73.0 99 108 91 1.6 3.000 3.88 4.26 3.57 3.6 76.1 mm 76.1 99 108 91 - - - - - - 1.6 3 3.500 425 506 417 - - - - - 45 80 88.9 108 129 106 2.0 4 4.500 9.63 6.00 3.88 2.75 3.50 2.00 4.50 3.50 3.35 20.0 100 114.3 245 152 99 70 89 51 114 89 85 9.1 5 5.563 10.50 6.80 4.50 - 4.17 2.15 5.88 4.08 3.98 27.0 125 141.3 267 173 114 106 55 149 104 101 12.3 5.500 10.50 6.80 4.50 4.17 2.15 5.88 4.08 3.98 27.0 139.7mm 139.7 267 173 114 - 106 55 149 104 101 12.3 6 6.625 1150 800 500 - 450 238 667 473 389 380 150 168.3 292 203 127 114 61 169 120 99 17.2 6.500 11.50 8.00 5.00 4.50 2.38 6.67 4.73 3.89 38.0 165.1 mm 6 165.1 292 203 127 - 114 61 169 120 99 17.2 8 8.625 1400 988 606 505 565 215 885 565 575 640 200 219.1 356 251 154 128 1 144 55 225 144 146 29.0 10 10.750 17.00 12.00 7.09 5.96 6.69 2.15 10.92 6.73 - 100.0 250 273.0 432 305 180 151 170 55 277 171 45.4 12 12.750 1950 1400 1 806 691 764 251 1281 773 - 1400 300 323.9 495 356 205 176 194 64 925 196 63.5 10.08 1479 Rev S Updated 03/2017 0 2017 Victaalic company. All rights reserved. victaulic.com 4 \4tluIicr victaulic.com p 4.1 DIMENSIONS Series 717H MOM Typical 2/50 mm - 3780 mm Size Dimensions Weight E to E Approximate Nominal A B C D E J K P R (Each) inches inches inches inches inches inches inches inches inches inches lb mm mm mm mm mm mm mm mm mm mm kg 2 8.66 6.46 3.23 1.48 3.02 2.80 - - 4.25 10.7 50 219.8 164.1 82.1 37.5 76.7 71.0 108.0 4.9 21/2 9.37 6.94 3.31 1.66 3.40 3.38 - - 4.38 13.8 65 238.0 176.3 84.1 42.2 86.4 85.9 111.3 6.3 761 mm 9.37 6.94 3.31 1.66 3.40 3.38 - - 4.38 13.8 238.0 176.3 84.1 42.2 86.4 85.9 111.3 6.3 3 9.62 7.44 3.53 1.91 3.65 3.38 - - 4.63 20.0 80 244.3 189.0 89.7 48.5 92.7 85.9 117.6 9.1 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. viCtauliC.com './tauhc. 10 victaulic.com 5.0 PERFORMANCE Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. S717H I 717HR '. .. • =!!!! U. ___.uI. 11 u•usuu liii !!!!!!! 1111111 100 Flow Rate - GPM S717H / 717HR 100.00 0 _i 10 a- Flow Rate - Litres/Mm. 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com \JtauIacI 0.1 10 1000 too 10 5.1 PERFORMANCE Flow Characteristics The charts below express the flow of water at 60°F/160C through valve. S717/717R Baal — sauii U I I * . : - ., . S S - II $11111 I 111ff! I I IHIIIIUIlhhIII UiIIiI I I = auii1n __uuuhla iuuiin Rflhlill auuiiuiii 111111 11111111111 I •uui u•uii II •iiHi uuuiii UIUIII UIHhII I IIIIII.IflhIIII 100 1000 10000 100000 Flow Rate - GPM S717 I 717R ___.. ..II a . _____.. URU _____.. NRIu __uUI uuII ___..aUI UIIII R1111 — U• I U11111 II' ..iuui UI -• " SI •. - 5 • I — a I uiii III 11111 111111 liii ian IIIIIII uuuii I ____.. .s.a - - ___..aII -- ..u.u. aauui uaiii — UUiI RU11111 __uu1lII suuulill 11111111 - III III 1111111 10 100 1000 10000 100000 Flow Rate - Litres/Mm. 0.1 10 10.08 1479 Rev S Updated 03/2017 0 2017 Victaulic Company. All rights reserved. victaulic.com 7 victaulic.com 6.0 NOTIFICATIONS WARNING Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. 7.0 REFERENCE MATERIALS 05.01 Seal Selection Guide 10.01: Regulatory Approval Reference Guide 29.01: Terms and Conditions/Warranty -100: Field Installation Handbook User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as lathe suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any ether document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision at Victaulic company's standard conditions at sate, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or ether countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products lobe installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to the Victaulic installation handbook or installation instructions of the product you are installing. Handbooks are included with each shipment of Victaulic products, providing complete installation and assembly data, and are available in POE format on our website at www.victaulic.cem. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaviic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.08 1479 Rev S Updated 03/2017 © 2017 Victaulic Company. All rights reserved. victaulic.com JtauIicf ASHCROFT® Fire Protection, Sprinkler Service Gauge Type 1005P, XUL ASME B 40.1 Grade B (±3-2-30/o of span) Underwriters Laboratory listed and Factory Mutual approved Corrosion-resistant ABS case Heat-resistant polycarbonate push-in window Patented PowerFlexTM movement with polyester segment True Zero TM indication, a unique safety feature Type no.: 1005P, XUL Accuracy: ASME B 40.1 Grade B (±323% of span) Size: 314" Case: ABS (Polycarbonate blend) Ring: None Window: Polycarbonate, push-in Dial: Black figures on white back- ground Pointer: Black, aluminum Bourdon tube: "C" shaped bronze Movement: Patented PowerF/ex with polyester segment Socket: Brass Restrictor: None Ashcroft® fire protection sprinkler gauges are Underwriters Laboratory listed and Factory Mutual approved for fire protection sprinkler service. The case material on Type 1005P, XUL gauges is ABS. The 0-300 psi pressure range is used on "wet' systems where water is available to the sprinkler heads. The 0-80 retard to 250 psi pressure range is used on dry systems where the lines are filled with air pressure until system activation. The patented PowerFlex move- ment with polyester segment is designed to provide unequalled shock and vibration resistance resulting in superior performance and extended gauge life. Operating temperature: —400F to 150°F Connection: 1/4 NPT lower Ranges: 0-300 psi (water) 0-80 retard to 250 psi (air) UL 393 Listed, UL of Canada Listed and FM approved. Equivalent (single or dual scale) metric scales are available True Zero indication, a standard feature on these gauges, reduces the potential risk of installing a dam- aged gauge on your equipment. Customized dials Other UL listed ranges on application I@LISTED I 1004 FOR 10504 AGENCY MARKS ON OUR PRODUCTS Select: 35 W 1005 P H 02L XUL 300# Dial Size: 31A' Patented PowerFleM Movement Case Type Number: 1005 Case Type Material: ABS Socket Material: Brass Connection Size/Location: 'A NPT lower UL listed, FM approved Range: 300 psi Consult factory for guidance in product selection _________Iq Phone (203) 385-0217, Fax (203) 385-0602 or Zjo visit our web site at www.ashcroft.com Instruments SAl -000-0000 X/ ictaulilc® AUTOMATIC SPRINKLERS FIRE PROTECTION PRODUCFS 'a Sprinkler Cabinets I I PRODUCT DESCRIPTION SA4-000-0000 Victaulic Automatic Sprin- kler Cabinets provide for storage of a supply of sprin- klers. Maintaining a supply of spare sprinklers on the premises of automatic sprinkler systems will aid in the prompt replacement of operated or damaged sprin- klers and returning a fire protection system to ser- vice as soon as possible. This is a requirement of NFPA and most Authori- ties Having Jurisdiction. Refer to the applicable NFPA standard governing your specific installation for further details. Six or twelve sprinkler capacity cabinets are avail- able. This also provides for storage of the appropriate wrench which is required for the installation and removal of sprinklers. NFPA 25 requires the total number of spare sprinklers to be stored on the pre- mises of an automatic sprinkler system meet the minimum quantities shown in the accompanying table. When the sprinkler system includes more than one type of temperature rating sprinkler, the stock of spare sprinklers must include a proportional sampling of each type and temperature rating: however, a mini- mum of 3 each is recom- mended. Sprinklers in Building Mm. Number of Spare Sprinklers Under 300 6 300t01000 12 Over 1000 24 A minimum of three sprinklers of each type and temperature rating are required for residential fire sprinkler systems in one- and two-family dwellings and mobile homes. SA2-000-0000 SA3-000-0000 TECHNICAL SPECIFICATIONS Models: LI 12 sprinklers U 6 sprinklers U 3 sprinklers (NFPA/3D, Residential) LI 6 large sprinklers Material: Heavy gauge steel, red enamel. Cabinets are available in six or twelve sprinkler capacities with dimensions and shelf variations as shown on page 2. The cabi- nets are of welded construction fabricated from low carbon steel sheet. The box and shelves are fabricated from 0.030 thick material and the cover is fabri- cated from 0.042 thick material. The cover is mounted to the box, at the top, with two 0.036' thick steel butt type hinges. A coat of red enamel paint is applied inside and out, and a label indi- cating that the cabinet is for spare sprinklers is bonded to the cover. VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1-800-PICK-VIC (1-800-142-5842) Phone: 416-615-5575 Phone:32-9-381-1500 Phone: 610-559-3300 Phone: 65-235-3035 Fax: 610-250-8817 Fax: 416-675-5565 Fax: 32-9-380-4438 Fax: 610-559-3608 Fax: 65-235-0535 e-mail:pickvic@victaulic.com e-mail: viccanada@viclaulic.com e-mail: viceuro@viclaulic.be e-mail: vical@viclaulic.com e-mail: vicap@victaulic.com 2561 Rev.B 7102 0 Registered Trademark of Victaulic © copyright 2002 Victaulic Printed in u.s.A. DIMENSIONS H wag Dimensions - Inches/millimeters Victaulic H W D Part Number Description Use With yb, V26, V29, V27, V34 (except 5.25 14.31 4.00 SAl -000-0000 For 12 Sprinklers V3403 & V3404) 133 364 102 SA2-000-0000 For 6 Sprinklers V27, V3403, V3404, V34 525 133 14.31 364 2.38 60 SA3-000-0000 For 3 Sprinklers (NFPA 13D) V27, V29 Residential 5.25 133 7.31 1 186 2.38 1 60 V40, V38, V39 Concealed, Kb ESFR, SA4-000-0000 For 6 Large Sprinklers All Intermediate Level Sprinklers, 6.50 165 14.31 364 3.13 79 All Guards* Specify part number and capacity when ordering. Guards will only fit if NOT assembled to sprinkler. Capacity may be reduced. I- INSTALLATION Automatic Sprinkler Cabinets must be installed and the spare sprinkler stock maintained in compliance with the applicable standards of the NFPA, in addition to the standards of any other Authorities Having Jurisdiction. Failure to do so may result in property damage and impair the ability to return an automatic sprinkler system to ser- vice as soon as possible. 7CAUTION The owner is responsible for maintaining a supply of spare sprinklers in proper condition. The installing contractor should be contacted with any questions. Failure to do so may result in property damage. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.81 -2 F P P I Description Pipefit® Thread Sealing Paste with PTFE is a premium non-hardening PTFE filled pipe thread sealing paste designed specifically for the fire sprinkler industry. Pipefit is suitable for use on all threadable materials commonly used in fire sprinkler systems, including CPVC. Pipefit's unique blend of materials provides superior thread sealing qualities over other similarly priced sealants. The particulate PTFE also helps prevent leaks by accumulating in the voids of damaged or defective threads of the pipe or fittings. Additionally, the lubricating qualities of the PTFE and other materials in the sealing paste improve thread seating during pipe and fitting assembly. Pipefit® also adheres well to hot oily pipe present in "high speed' fabrication operations. Design Criteria/Data Recommended Use Water Air Refrigerants Natural Gas Mild caustics Steam Kerosene LP Gases Acids Gasoline Diesel Fuel Ammonia Use for threaded connections on steel, aluminum, brass, PVC, CPVC and ABS. Operating temperature ranges -50fto 500f. FBC; SYSTEM COMPA11BLE *FBCTI System Compatible indicates this product has been tested by Lubrizol Advanced Materials and is monitored on an on going basis to assure chemical compatibility with FlowGuard Gold®, BlazeMaster®, and Corzan® pipe and fittings. 3198 LIONSHEAD AVE CARLSBAD, CA 92010 TEL + 1760 599-1168 +1800344-1822 FAX + 1800 344-3775 Installation Make sure that the threads are free from burs and other debris. Apply Pipef it® liberally to the male pipe threads. Make sure that the thread sealant is brushed into the "root" of the threads. Do not wipe off excess material until fitting has been "made on" to the pipe thread. The threading action of the fitting to the pipe will allow the proper amount of sealant to remain in the connection. Wipe off excess sealant. Pipefit® will not dry out under normal conditions. Never use dope and tape together. Keep covered when not in use to avoid contamination. Some settling of the product may occur. Occasional stirring may be necessary. Two year shelf life. Disclaimer DO NOT ALTER THE CONSISTENCY OF THIS PRODUCT. Use as is directly from the container. Keep away from your mouth and eyes. If eye contact occurs, flush with water for 5 minutes. If discomfort persists get medical attention. Specifications Appearance: Dense, paste-like consistency, off white in color. Packaging: 16 oz. brush in cap 32 oz. 32 oz. BIC 1 gl. 5 gl. 55 gl. CAUTION: See MSDS for first aid instructions. Wash hands thoroughly after each use. See Material Safety Data Sheet for additional safety and disposal information at www.fppi.com Nu © 2012 Fire Protection Products, Inc. FPPI®, LubeFit' are registered trademarks of Fire Protection Products, Inc. kA FBC", BIazeMaster, FlowGuard Golds and CorzanO are registered trademarks of Noveon IP Holdings Corp. MADE IN U.S.A. DIEGO 7635 RONSON ROAD • SAN DIEGO CA 92111 • TEL 858-278-3270 • FAX 858-278-2950 E-MAIL: salessandiegoseal.com • VISIT US AT: wwwsandiegoseal.com PTFE Thread Sealant Tapes Made in the USA Our thread sealant tape breaks clean without shredding or warping, identifying it as a product that can be trusted to perform reliably when the job is completed and the pressure is on. Standard Grade - Our standard grade PTFE Thread Sealant Tape is for those ,fl SLI applications that do not require the sealing properties of a premium grade thread sealant. This is intended to be used for I1 .. general purpose sealing in pipe threads. The standard density virgin PTFE sealant tape permits quick, clean, / economical sealing of male pipe threads of all sizes and reduces the risk of system contamination common with liquid and paste sealants. High-Density Thread Sealant Tape It is effective and efficient so you can use less tape. Tears cleanly.. .seals neatly Quick sealing: This premium high density PTFE sealant tape permits quick, clean sealing of male pipe threads of all sizes and eliminates the risk of system contamination common with liquid and paste sealants. Self-lubricating: The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble, and extends the fatigue life of sealed connections. Durable: Totally maintenance free premium high density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (-240°C) to +500°F (+260°C), and pressures from hard vacuum to 10,000 PSI. Full Density Yellow Gas Line PTFE Thread Sealant Tapes risk of system contamination common with liquid and paste sealants. Our full density premium and gas line tapes meet Mil Spec A-A 58092 for liquid & gaseous oxygen applications. The self-lubricating quality of this unsintered tape makes joints easy to assemble and disassemble. Totally maintenance free, full density PTFE thread sealant tape is virtually chemically inert, non-toxic, non-absorbent and non-flammable. It will withstand temperatures from -450°F (- 40°C) to +500°F (+260°C), and pressures from a hard vacuum to 10,000 PSI. Typical properties of PTFE thread sealant tape are as follows: Typical Properties - -- - Grade Standard Grade 1 Premium Grade jPremium Grade IPrnium Grade - St Yellow - - - andard Density IHigh Density IFull Density IFull Density Description The economical choice More sealing power Maximum sealing power. So efficient, can use less ape. Complies with certain building codes requiring yellow, thicker, more dense tape service lines ••' /- color JWhite or colors iNhte or colors Nhite or colors JYellow - - •. .a _____________________________________ Standard 1.5 jStandard 1.6 Density Standard 0 5 to 0.7 jStandard 1 O to 1 2 Thickness 0.003" to 00035 10003 t000035 0 003 to 0.0035" 1 Standard Widths & Lengths 1/4 x 260 1/4"x 520" r/4" x 1296' /2" x 260" %" x 520" /2" x 1296" / x 260" Y' x 520" /4" x 1296" 1" x 260" 1" x 520" 1" x 1296" Quantity 144 rolls per box 144 rolls per box 144 rolls per box Color11 Typical Use Nhite All industrial applications. Made from virgin PTFE ink For use in plumbing and pipe fittings (water and steam lines) Gray For stainless steel pipe/fittings 3ren For oxgpplications Yellow For gas line use SAN DIEGO SEAL, INC 7635 RONSON ROAD • SAN DIEGO, CALIFORNIA 92111 TEL: 858-278-3270 • FAX: 858-278-2950 E-MAIL: salessandiegoseaI.com • VISIT US AT: www.sandiegoseal.com Product Information IILI1 FS-ONE High Performance Intumescent Firestop Sealant Product description O Intumescent (expands when exposed to fire) firestop sealant that helps protect combustible and non-combustible penetrations for up to 4 hours fire rating Product features 0 Smoke, gas and water resistant after material has cured O Contains no halogen, solvents or asbestos High fire rating properties 0 Water based, easy to clean O Protects most typical firestop penetration applications 0 Paintable 0 Single component systems available 0 Meets LEED requirements for indoor environmental quality credit 4.1 Low Emitting Materials, Sealants and Adhesives and 4.2 Paints and Coatings Areas of application Steel, copper and EMT pipes 0 Insulated steel and copper pipes 0 Cable bundles 0 Closed or vented plastic pipes 0 HVAC penetrations For use with O Concrete, masonry, drywall and wood floor assemblies 0 Wall and floor assemblies rated up to 4 hours Examples 0 Sealing around combustible pipe penetrations in fire rated construction 0 Sealing around non-combustible penetrations in fire rated construction Installation instructions for FS-ONE Technical Data* Chemical basis FS-ONE Water-based intumescent acrylic dispersion Color Red Application temperature 40°F to 104°F (5°C to 40°C) Skin forming time Approx. 20-30 mm. Curing time Approx. 2 mm / 3 days Movement capability Approx. 5% Expansion rate (unrestricted) Up to 3-5 times original volume Temperature resistance (cured) -40°F to 212°F (-40°C to 100°C) Surface burning characteristics (ASTM E 84-96) Flame Spread: 0 Smoke Development: 5 Sound transmission classification (ASTM_E 90-99) 56 (Relates to specific construction) Approvals California State Fire Marshal - No. 4485-1200:108 City of New York - MEA 326-96-M Vol. IV Tested in accordance with UL1479 •ASTME814 •ASTME84 At 73°F (23°C) and 50% relative humidity t,suLn, FILL, VOID OR CAVITY MATERIAL Iiiiiie u ° FOR USE IN THROUGH-PENETRATION Ae> UL FIRESTOP SYSTEMS $'EYEI cOUPAnete SEE UL FIRE RESISTANCE DIRECTORY 66Y7 APPROVED Notice Before handling, read Material Safety Data Sheet and product label for safe usage and health information. Instructions below are general guidelines - always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Opening clean the opening. Surfaces to which FS-ONE will be applied should be cleaned of loose debris, dirt, oil, moisture, frost and wax. Structures supporting penetrating items must be installed in compliance with local building and electrical standards. Application of firestop sealant Install the prescribed backfilling material type and depth to obtain the desired rating (if required>. Leave sufficient depth for applying FS-ONE. Application of firestop sealant: Apply FS-ONE to the required depth in order to obtain the desired fire rating. Make sure FS-ONE contacts all surfaces to provide maximum adhesion. For application of ES-ONE use a standard caulking gun, toil pack gun, bulk loader and bulk gun. With FS-ONE buckets, Graco type sealant pumps may be used. (Contact pump manufacturer for proper selection). Smoothing of firestop sealant: To complete the seal, tool immediately to give a smooth appearance. Excess sealant, prior to curing, can be cleaned away from adjacent surfaces and tools with water. Leave completed seal undisturbed for 48 hours. For maintenance reasons, a penetration seal could be permanently marked with an identification plate. In such a case, mark the identification plate and fasten it in a visible position next to the seal. Not for use Nigh movement expansion joints On materials where oil, plasticizers or solvents may bleed i.e. impregnated wood, oil based seals, green or partially vulcanized rubber In any penetration other than those specifically described in this manual or the test reports Storage Store only in the original packaging in a location protected from moisture at temperatures between 40°F (5°C) and 86°F (30°C) Observe expiration date on the packag Underwater 4o I. Clean opening. 2. Pack mineral wool. 3. Apply FS-ONE. 4. Smooth 5. Leave completed 6. Fasten identification Of required) FS-ONE. seal undisturbed for plate Qtrequurnc. 46 hours, Na I. Clean opening. 2. Pock minaret wool. 3. Apply FS-ONE. 4. sn,00th 5. Leave completed 6. Fasten Identification Of required) FS-ONE. seal undisturbed for plate ffrequoredl. 48 hours. Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 • www.us.hilti.com • en español 1-800-879-5000 • Hilti Firestop Systems Guide MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: lof2 Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. RO. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Ingredients: CAS Number: PEL: TLV: STEL: Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/ml (I) 10 mg/m, (1) NE Zinc borate 12-8 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 rnppcf 2 mg/m` NE Expandable graphite 012777-87-6 5 mg/rn3 (1) 2 mg/ml (F) NE Ethylene glycol 000107-21-1 NE C:100 mg/ml (A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 mg/m, 5 mg/ml NE Glass filament 065997-17-3 NE 5 mg/ml (F) NE Silicon dioxide 014808-60-7 0.05 mg/rn3 (1) 0.1 mg/m, (1) NE Water 007732-18-5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (T) indicates "as total dust". (R) indicates "as respirable fraction". (A) indicates "as an aerosol". mppcf = million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air = 1) Not determined. Vapor Pressure: 23mbar @ 200 / 68F Boiling Point: Not applicable. VOC Content: 75.0 gIL Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity; 1.5 pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Flammable Limits: Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting Procedures: None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Unusual Fire and Explosion Hazards: None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur and phosphorous. REACTIVITY DATA Stability; Stable Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides, and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and 002. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Exposure: Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. 'V13 Hilti Firestop Saving Lives through innovation Hilti. Outperform. Outlast. and education Huh, Inc. (U.S.) •1-800-879-8000 • www.us.hlla.com 9 en espafiol 1-800-879-5000 • Huh (Canada) Corp. 1-800-363-4458 www.hlltLca MSDS No.: 259 Revision No.: 010 Revision Date: 08/17/04 Page: 20f2 Carcinogenicity: [ARC classifies crystalline silica (quartz sand) as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, qUarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist. Ingestion: Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the Injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing Precautions: Store in a cool, dry area preferably between 40o and 77o F. Keep from freezing. Do not store in direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled, material before it hardens. Place in a container for proper disposal in accordance with all applicable lOcal, state, or federal requirements. REGULATORY INFORMATION Hazard Communication: HMIS Codes: DOT Shipping Name: IATA / ICAO Shipping Name: TSCA Inventory Status: EPA Waste Code(s): Waste Disposal Methods: CONTACTS This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. Health 1, Flammability 0, Reactivity 0, PPE B Not regulated. Not regulated. Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product contains < 3% ethylene glycol (CAS 107-21-1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title III (40 CFR Part 372). Not regulated by EPA as a hazardous waste. Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health I Safety: 1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. 1 Hllti Firestop Saving Lives , through innovation L . and education Hilti. Outperform. Outlast. Hilti. Inc. (U.S.) 1-800-879-8000 • www.us.hlltl.com • en español 1-800-879-5000 9 Hitti (Canada) Corp. 1-800-363-4458 www.tdltLca Certificate Number 20100512-RI 3240 Report Reference 2010 May 12 Issue Date 2010 May12 Page 1 of I [JJ Underwriters IL Laboratories Inc. Issued to: Hilti, Inc. 54 S 122ND East AVe Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated by Underwriters Laboratories Inc.® (UL) or any authorized licensee of UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, ANSI/UL 2079, CAN/ULC-S115-05 Third Edition, revised March 1, 2010 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through-Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. 1 The UL Classification Mark includes: UL in a circle symbol: 0 with the word CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product 4 category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued by: Review Mona Couloute Chris . J nson Underwriters Laboratories Inc. Underwriters Laboratories Inc. Any information ond documentation involving UL Mark services are provided on behalf of Underwriters Laboratories Inc. (UL) or any authorized licensee of UL. Certificate Number 20060214-R13240E Report Reference 2006 February 14 Issue Date 2006 February 14 Page 1 of I ® Underwriters Laboratories Inc..; Issued to: Hilti, Inc. 5400 S 122ND East Ave Tulsa, OK 74146 USA This is to certify that Fill, Void or Cavity Materials representative samples of FS-ONE Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: ANSI/UL 1479, ANSI/UL 2079, CAN/ULC-S1 15-05 Additional Information: FS-ONE Sealant for use in Joint Systems and FS-ONE for use in Through- Penetration Firestop Systems as currently described in the UL Fire Resistance Directory. Only those products bearing the UL Classification Mark should be considered as being covered by UL's Classification and Follow-Up Service. The lil. Classification Mark includes: UL in a circle symbol: 0 with the word "CLASSIFIED" (as shown); a control number (may be alphanumeric) assigned by UL; a statement to indicate the extent of UL's evaluation of the product; and, the product category name (product identity) as indicated in the appropriate UL Directory. Look for the UL Classification Mark on the product Issued by: Reviewed by I1,xi; M6na Couloute ChristoPherL o Underwriters Laboratories Inc. Underwriters s on Inc. Hilti North America 5400 South 122nd East Avenue Tulsa, OK 74146 P.O. Box 21148 I Tulsa, OK 74121-1148 T 1-800-879-8000 I F 918-252-6742 www.hilti.com June 27, 2008 To Whom It May Concern: Re: Hilti ES-ONE Intumescent Firestop The Hilti ES-ONE Intumescent Eirestop is manufactured in Kaufering, Germany. The ES-ONE pail is made of polyethylene and can be completely recycled. There is no post- consumer or post-industrial content in ES-ONE and it cannot be recycled. The VOC content for FS-ONE is 75 grams/liter. FS-ONE is not regulated as a hazardous waste by the Federal EPA Standards. The regulations for the disposal of non-regulated industrial waste can vary from state to state and even city to city. For this reason, you should consult your local and state regulatory agencies for direction on disposal. Please feel free to contact me at (918) 252-6704 if you have questions. Sincerely, Jerry Metcalf MPH, CHMM Safety/Environmental Manager Hilti Inc (918) 252 6704 Ierrv.metcaIfhiIti.com NOTES! DEFINITIONS: Post-Consumer Recycled Content: Portion of material or product derived from discarded consumer waste that has been recovered for use as a raw material [e.g., plastic bottles, newspaper] Post-Industrial Recycled Content: Portion of material or product derived from recovered industrial and mfg. materials that are diverted from municipal solid waste for use in a different mfg. process, prior souse by a consumer [e.g., fly-ash in concrete or synthetic gypsum board, both of which are by-products of coal-burning power plants]. Spills and scraps from the original manufacturing process that are combined with other constituents after a minimal amount of reprocessing for use in further production of the same product do not qualify. Manufactured: Final assembly of components into building product that is famished and installed by trades [e.g., if the hardware comes from Dallas, TX, the lumber from Keene, NH, and the joist is assembled in Kent, WA; then the location of final assembly is Kent, WA]. www,osvisualizer.com/calculators can be used to calculate straight-line distance between project site / New York, NY and location of manufacture and raw material source. Note: location noted on material data sheets is often corporate location; need manufacturer to verify actual manufacture location. Raw Materials: Virgin or recovered resources from which the product's components are made [i.e., before processing or manufacturing]. Rapidly Renewable: Materials and products made from raw materials that are harvested within a 10-year cycle [e.g., bamboo, cork, linoleum, fast-growing poplar, wheatboard, wool carpet]. FSC Certified. Wood-based products that are certified by the Forest Stewardship Council and carry a Chain-of-Custody certificate number from the vendor or manufacturer. VOC Content: The quantity of volatile organic compounds contained in products such as adhesives, sealants and architectural coatings. VOC content is to be reported in grams/liter or lbs/gallon, less water and any exempt compounds/solvents. CONTRACTOR CERTIFICATION: I, a duly authorized representative of hereby certify that the information contained herein accurately represents the listed "green building" characteristics of the matenal_to be provided by our company as components of the building construction. Furthermore, J I understand that any change in such "green building" material characteristics during the purchasing and/or installation period will require prior written approval from the Construction Manager and Owner. SIGNATURE OF AUTHORIZED REPRESENTATIVE: DATE: MSDS No.: Revision No.: Revision Date: 259 010 08/17/04 1 of MATERIAL SAFETY DATA SHEET Product name: FS-ONE High Performance Intumescent Firestop Sealant Description: One-part acrylic-based sealant Supplier: Hilti, Inc. P.O. Box 21148, Tulsa, OK 74121 Emergency # (Chem-Trec.): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) INGREDIENTS AND EXPOSURE LIMITS Lgpts Number PEL TLV S. I Polyacrylate dispersion Mixture NE NE NE Calcium carbonate 001317-65-3 5 mg/m3 (T) 10 Mg/M3 (T) NE Zinc borate 138265-88-0 NE NE NE Ammonium polyphosphate 068333-79-9 NE NE NE Talc 014807-96-6 20 mppcf 2 Mg/M3 NE Expandable graphite 012777-87-6 5 Mg/M3 (1) 2 Mg/M3 (1) NE Ethylene glycol 000107-21-1 NE C:100 Mg/M3 (A) NE Polybutene 009003-29-6 NE NE NE Iron oxide 001309-37-1 10 Mg/M3 5 Mg/M3 NE Glass filament 065997-17-3 NE 5 Mg/M3 (T) NE Silicon dioxide 014808-60-7 0.05 Mg/M3 (T) 0.1 Mg/M3 (T) NE Water 007732-18-5 NE NE NE Abbreviations: PEL = OSHA Permissible Exposure Limit. TLV = ACGIH Threshold Limit Value. C = Ceiling. STEL = Short Term Exposure Limit. NE = None Established. NA = Not Applicable. (1) indicates "as total dust". (R) indicates "as respirable fraction". (A) indicates "as an aerosol". mppcf = million particles per cubic foot. PHYSICAL DATA Appearance: Red paste. Odor: Odorless. Vapor Density: (air= 1) Not determined. Vapor Pressure: 23mbar @ 20C / 68F Boiling Point: Not applicable. VOC Content: 75.0 g/L. Evaporation Rate: Not applicable. Solubility in Water: Soluble. Specific Gravity: 1.5 ..pH: Not determined. FIRE AND EXPLOSION HAZARD DATA Flash Point: Non-flammable. Limits: • Not applicable. Extinguishing Media: Not applicable. Use extinguishing media as appropriate for surrounding fire. Special Fire Fighting None known. Use a self-contained breathing apparatus when fighting fires involving chemicals. Procedures: Unusual Fire and Explosion None known. Thermal decomposition products can be formed such as oxides of carbon, sulfur Hazards: and phosphorous. REACTIVITY DATA Stability: Stable. •Hazardous Polymerization: Will not occur. Incompatibility: Strong acids, peroxides, and oxidizing agents. Decomposition Products: Thermal decomposition can yield CO and CO2. Conditions to Avoid: None known. HEALTH HAZARD DATA Known Hazards: None known. Signs and Symptoms of Possibly irritating upon contact with the eyes or upon repeated contact with the skin. Exposure: Medical Conditions Eye and skin conditions. Aggravated by Exposure: Routes of Exposure: Dermal. HILTI 0 is a registered trademark of Hilti Corp. Carcinogenicity: IARC classifies crystalline silica (quartz sand) as Group I based upon evidence among workers in industries where there has been long-term and chronic exposure (via inhalation) to silica dust; e.g. mining, quarry, stone crushing, refractory brick and pottery workers. This product does not pose a dust hazard; therefore, this classification is not relevant. Based upon the nature and intended use of this product, it does not pose an increased cancer risk to workers. EMERGENCY AND FIRST AID PROCEDURES Eyes: Immediately flush with plenty of water. Call a physician if symptoms occur. Skin: Immediately wipe off material and wash with soap and water. Material can adhere to the skin. If material has adhered to the skin, use an abrasive containing hand cleaner. If material does not come off, buff with a pumice stone. Inhalation: Move victim to fresh air if discomfort develops. Call a physician if symptoms persist Ingestion: , Seek medical attention. Do not induce vomiting unless directed by a physician. If a large quantity was ingested, give 1 to 2 glasses of water to dilute. Never give anything by mouth to an unconscious person. Other: Referral to a physician is recommended if there is any question about the seriousness of the injury/exposure. CONTROL MEASURES AND PERSONAL PROTECTIVE EQUIPMENT Ventilation: General (natural or mechanically induced fresh air movements). Eye Protection: Not required, however, safety glasses should be worn in most industrial settings. Skin Protection: Avoid skin contact. Cloth gloves are suitable for hand protection. Respiratory Protection: None normally required. Where ventilation is inadequate to control vapors, use a NIOSH- approved respirator with organic vapor cartridges. Never enter a confined space without an appropriate air-supplied respirator. PRECAUTIONS FOR SAFE HANDLING AND USE Handling and Storing . Store in a cool, dry area preferably between 400 and 770 F. Keep from freezing. Do not store in Precautions: direct sunlight. Avoid contact with the eyes or skin. Practice good hygiene; i.e. always wash thoroughly after handling and before eating or smoking. For industrial use only. Keep out of reach of children. Follow label/use instructions. Spill Procedures: Immediately wipe away spilled material before it hardens. Place in a container for proper disposal in accordance with all applicable local, state, or federal requirements. REGULATORY INFORMATION Hazard Communication: This MSDS has been prepared in accordance with the federal OSHA Hazard Communication Standard 29 CFR 1910.1200. HMIS Codes: Health 1, Flammability 0, Reactivity 0, PPE B DOT Shipping Name: Not regulated. IATA I ICAO Shipping Name: Not regulated. TSCA Inventory Status: Chemical components listed on TSCA inventory. SARA Title III, Section 313: This product contains < 3% ethylene glycol (CAS 107-21-1) and < 15% zinc borate (re: zinc compounds) which are subject to reporting under Section 313 of SARA Title Ill (40 CFR Part 372). EPA Waste Code(s): Not regulated by EPA as a hazardous waste. Waste Disposal Methods: Consult with regulatory agencies or your corporate personnel for disposal methods that comply with local, state, and federal safety, health and environmental regulations. CONTACTS Customer Service: 1 800 879 8000 Technical Service: 1 800 879 8000 Health I Safety: '1 800 879 6000 Jerry Metcalf (x6704) Emergency # (Chem-Trec): 1 800 424 9300 (USA, PR, Virgin Islands, Canada); 001 703 527 3887 (other countries) The information and recommendations contained herein are based upon data believed to be correct; however, no guarantee or warranty of any kind expressed or implied is made with respect to the information provided. MSDS25Q, Page 2of2 CALIFORNIA DIiIPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE CAL FIRE LISTING No. 4485-1200:108 Page 1 of 1 CATEGORY: Opening Protection (Firestopping) LISTEE: Hilti, Inc., 5400 S. 122nd East Ave, Tulsa, OK 74146 Contact: *Clay Hensley (918) 252-6216 Fax (918) 254-1679 DESIGN: Model ES-ONE Firestop Sealant. Refer to listee's printed data sheet and UL Fire Resistance Directory for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, type identification and UL label. APPROVAL: Listed as firestop devices for use in through-penetration firestop system up to 3 hour rating. For indoor use only. Approved under Through-Penetration Fire Stop Systems: CAJ1155, CAJ2091, CAJ2II8, CAJ3095, CAJ5044, CAJ8041, F-C-2025, WL1085, WL1056, WL3047, WL5029, WL8004. Refer to UL Fire Resistance Directory for detailed constructions. *Rev. 06-20-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 10, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division ,BUILD! NYC Department of Buildings 280 Broadway, New York, NY 10007 Patricia Lancaster, FAIA, Commissioner (212) 566-5000, TTY: (212) 566-4769 Report of Materials and Equipment Acceptance Division Pursuant to Administrative Code Section 27-131, the following equipment or material has been found acceptable for use subject to the terms and conditions contained herein. MEA 326-96-M Vol. 5 Manufacturer: Hilti, Inc, 5400 S. 122 East Avenue, Tulsa, OK 74146 Trade Name(s): Product: Pertinent Code Section(s): Prescribed Test(s): Laboratory: Hilti, Inc. Fill, void or cavity material for fire protection 27-345 RS 5-19 (ASTM E814), UL 2079 Underwriters Laboratories, Inc. Test Report(s): File R13240, dated July 16, 1993, July 21, 1993, July 13, 1993, July 22, 1993, April 1, 1993, March 25, 1994, March 3 and 6, 1995, September 4, 1996, September 27,1997; File R13644, dated April 12, 1993 and May 3, 1993; File R12232, dated August 2, 1993; UL-design listings. Description: Fill, void or cavity material for through-penetrations in fire-rated wall and/or floor/ceiling construction. The Hilti FS-ONE Firestop Sealant shall be applied in accordance with Underwriters Laboratoris inc system numbers, listed on fQllowing pages, in achieving the required fire-resistance ratings. MEA326-96-M Vol.5 Page 1 of 10 , pC~ Qo)-~ Contractor's Material and Test Certificate for Aboveground Piping PROCEDURE Upon completion of work, inspection and tests shall be made by the contractor's representative and witnessed by an owner's representative (hereinafter defined as property owner). All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood that the property owner's authorized representative is a legal signatory and fully representative of the property owner and that by the property owner's or property owner's authorized representative's signature, the property owner accepts full responsibility for the system as installed and agrees that it is in compliance with the applicable approving authority's requirements and local ordinances. Property Name STATE MIXED USE 30 Date 2-10-20 Property Address 3068 STATE ST 3080 Accepted by Approving Authorities (Names) CITY OF CARLSBAD Address Plans Installation conforms to accepted Plans Z Yes 0 No Equipment used is approved 2J Yes 0 No If no, explain deviations Has the property owner or property owner's authorized representative been instructed as to the location of control valves and care and maintenance of this new equipment? 121 Yes 0 No If no, explain Have copies of the following been given to the property owner or property Instruction owner's authorized representative? System Components Instructions 121 Yes 0 No Care and Maintenance Instructions 121 Yes 0 No NFPA25 121 Yes 0 No Location Of System Supplies Buildings VK462 K5.6 1/2' 8 155 VK305 K5.8 1/2" 1 200 Year Temperature Make Model of Manufacture Orifice Size Quantity Rating VIKING VK302 K5.6 1/2" 30 200 Sprinklers VIKING VK468 K4.9 7/16" 186 175 VIKING VK494 K4.9 7/16" 204 155 VIKING VK300 K5.6 1/2" 189 200 Pipe and Type of Pipe Fittings Type of Fittings CPVC PIE w/CPVC FITTINGS / STEEL PIPE w/GROOVED AND THREADED FITTINGS Maximum time to operate Alarm Valve Alarm Device through test connection or Flow Type Make Model Minutes Seconds Indicator ELECTRIC POTTER VSR-4 Dry Valve Q.O.D. Make Model Serial No. Make Model Serial No. Time to trip Trip Point Time Water through test Water Air Air Reached Test Alarm Operated Properly Dry Pipe connection* Pressure Pressure Pressure Outlet* Operating Mm/Sec psi psi psi Mm/Sec Yes No Test w/o Q.O.D. with Q.O.D. If No, explain measured from time inspectors test opened (NFPA 13 only requires the 60-second limitation in specific sections) Operation LI Pneumatic LI Electric LI Hydraulic Piping Supervised LI Yes LI No Detecting Media Supervised 0 Yes LI No Does valve operate from the manual trip, remote, or both control stations? LI Yes 0 No Is there an accessible facility in each circuit for testing? If no, explain Deluge & 0 Yes 0 No Preaction Valves Does each circuit operate Doe each circuit operate valve Maximum time to operate Make Model supervision loss alarm? release? release Yes No Yes No Min Sec Location Make and Residual Pressure Pressure and Floor Model Setting Static Pressure (flowing) Flow Rate Reducing Valve Test Inlet (psi) Outlet (psi) Inlet (psi) Outlet (psi) Flow (gpm) _______________________ HYDROSTATIC: Hydrostatic tests shall be made at not less than 200 psi (13.6 bar) for two hours or 50 psi (3.4 bar) above static pressure in excess of 150 psi (10.2 bar) for two hours. Differential dry-pipe valve clappers shall be left open during the test to prevent Test damage. All aboveground piping leakage shall be stopped. Description PNEUMATIC: Establish 40 psi (2.7 bar) air pressure and measure drop, which shall not exceed 1 1/2 psi (0.1 bar) in 24 hours. Test pressure tanks at normal water level and air pressure and measure air pressure drop, which shall not exceed 1 1/2 psi (0.1 bar) in 24 hours. All piping hydrostatically tested at ?,J_psi (_ bar) for _hours If no, state reason Dry piping pneumatically tested LI Yes LI No Equipment operates properly LI Yes LI No Do you certify as the sprinkler contractor that additives and corrosive chemicals, sodium silicate or derivatives of sodium silicate, brine, or other corrosive chemicals were not used for testing system or stopping leaks? Yes LI No Drain Rea ing of gauge located near water supply test connection Residual pressure with valve in test connection open wide Tests Test 1 75 psi (bar) - psi (_bar) Underground mains and lead-in connections to system risers flushed before connection made to sprinkler piping Verified by copy of the U Form No. 85B LI Yes LI No Other Explain Flushed by installer of underground sprinkler piping E 'Yes LI No If powder-driven fasteners are used in concrete, has LI Yes 0 No If no, explain representative sample testing been satisfactorily completed? Blank Number Used Locations Number Removed Testing Gaskets Welded Piping LI YES LI NO If Yes... Do you certify as the sprinkler contractor that welding procedures comply with the Requirements of at least AWS B2.1? Yes LI No Do you certify that the welding was performed by welders qualified in compliance Welding With the requirements of at least AWS 82.1? Yes LI No Do you certify that welding was carried out in compliance with a documented quality Control procedure to insure that all discs are retrieved, that openings in piping are Smooth, that slag and other welding residue are removed, and that the internal Diameters of piping are not penetrated? @ Yes 0 No Cutouts Do you certify that you have a control feature to ensure that all cutouts (discs) are (Discs) Retrieved? I1 Yes LI No Hydraulic Nameplate provided g Yes LI No If no, explain Data Nameplate Remarks Date left in service with all control valves open z - / q Name of Sprinkler Contractor Tests Witnessed by: Signatures For property owner (printed name) Signature Title Date /14p.,t9i .-JA-- For sprinkler contractor (printed name) _//Signature Title Date ___________ Additional Explanation and Notes: