Loading...
HomeMy WebLinkAbout3304 JAMES DR; ; FPR2021-0060; PermitCity of C "' arlsbad Lft Print Date: 06/15/2022 Job Address: 3304 JAMES DR, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2050604200 Track #: Valuation: $432,692.70 Lot #: Occupancy Group: Project U: #of Dwelling Units: Plan U: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check U: Permit No: FPR2021-0060 Status: Closed - Finaled Single Family Fire Sprinkli Applied: 06/02/2021 Issued: 06/30/2021 Finaled Close Out: 06/09/2022 Final Inspection: INSPECTOR: Salcedo, Felix Project Title: Description: 3304 JAMES DR -NEW 13D SPRINKLER SYSTEM FOR NEW SFR (30 HEADS) Applicant: FPContractor: INNOVATIVE FIRE PROTECTION INNOVATIVE FIRE PROTECTION INC DERIK BROOKS 8779 COTTONWOOD AVE, U STE 101 8779 COTTONWOOD AVE SANTEE, CA 92071-4457 SANTEE, CA 92071-4457-SAN DIEGO (619) 593-8200 (619) 593-8200 FEE AMOUNT FIRE NFPA 13D Single Family System (lnsp/Bldg) $125.00 FIRE NFPA 13D Single Family System (Plan Review) $246.00 Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov S HYDRAULIC CALCULATIONS for Job Information -- - Project Name: 3304 JAMES DRIVE Contract No. : C8141 City: CARLSBAD, CA 92008 Project Location: 3304 JAMES DRIVE Date: 5/27/2021 Contractor Information Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: DERIK@IFPINC.NET Name of Designer: DERIK BROOKS Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 1 Remote Area Location BEDROOM 4 Occupancy Classification RESIDENTIAL Density (gpm/ft2) 0.051 Area of Application (if2) 512 Coverage per Sprinkler (ft2) 256 Number of Calculated Sprinklers 2 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 31.2 Required Pressure at Source (psi) 59.9 Type of System Wet Volume - Entire System (gal) 23.3 gal Water Supply Information 5/20/2021 Date Location SITE Source 1 Notes File: C:\Users\derik\AppDataLocaI\Temp\C8141 3303 JAMES DRIVE _1_21 12_462c9c67.sv$ Date 5/27/2021 Copyright 0 2002-2012 Tyco Fire Protection Products Page 1 Job: 3304 JAMES DRIVE Hydraulic Analysis for: I Calculation Info Calculation Mode Hydraulic Model Fluid Name Fluid Weight, (lb/ft3) Fluid Dynamic Viscosity, (lb•s/ft2) Water Supply Parameters Supply 1: 1 Supply Analysis Demand Hazen-Williams Water © 60F (15.6C) N/A for Hazen-Williams calculation. N/A for Hazen-Williams calculation. Flow (gpm) Pressure (psi) 0 66.6 500 61 I Static Pressure I Residual I I Flow I Available I I i Total Demand I Required Pressure Node at Source I (psi) Pressure I I I (gpm) Pressure I I (gpm) (psi) (psi) I (psi) i I 1 66.6 61 500 66.6 31.2 59.9 Hoses Inside Hose Flow! Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers Ovehead Sprinkler Flow (gpm) 26.2 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 26.2 Other Required Margin of Safety (psi) 0 -Pressure (psi) 59.9 1 - Flow (gpm) 31.2 Demand w/o System Pump(s) N/A File: C:\Users\derik.AppData\LocalTemp\C8141 3303 JAMES DRIVE_1_2112_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 2 Job 3304 JAMES DRIVE Hydraulic Analysis for: I File: C:\Usersdenk'AppData\LocaI\Temp\C8141 3303 JAMES DRIVE _1_21 12_462c9th7.sv$ Date 5/27/2021 Copyright 2002-2012 Tyco Fire Protection Products Page 3 Job: 3304 JAMES DRIVE Hydraulic Analysis for: I Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 -Static 0 66.6 S2 Supply point #2 - Residual 500 61 Dl Elevation Pressure 0 9.1 D2 System Demand 31.2 59.9 Curve Intersections & Safety Margins Curve Name Intersection I Safety Margin Pressure (psi) I Flow (gpm) I Pressure (psi) I © Flow (gpm) Supply 66.6 33.3 6.7 1 31.2 Open Heads Required Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/psi1/2) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 101 Overhead Sprinkler 256 4.9 0.05 12.8 7 0.051 13 7 102 Overhead Sprinkler 256 4.9 0.05 12.8 7 0.052 13.2 7.2 File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE_1_21 12_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 4 'Job: 3304 JAMES DRIVE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) Wpm) (in) (ft) (ft) (psi) (psi) Path No: I 101 20 4.9 13 1 lx(BM.Tee-Br)=5 10.96 150 7 02 21 13 1.101 lx(BM.90)=5 10 0.0304 -0.4 20.96 0.6 02 21 13.2 1 8x(BM.90)=40 92.49 150 7.2 4-0 4.54 26.2 1.101 4x(BM.Tee-Br)=20 69 0.1113 7.1 9x(BM.Tee-Run)=9 161.49 18 4-0 4.54 0 1 1.08 32.3 RESI-RISER 4-1 3.46 26.2 0 0 5.9276 0.5 *** 1.08 6.4 4-1 3.46 0 1 1.46 150 39.2 3 2 26.2 1.101 0 0.1113 0.6 1.46 0.2 3 2 0 1 lx(us.90)=2.7 4 150 40 3A -1 26.2 1.025 2.7 0.1577 1.3 6.7 1.1 3A -1 0 1.5 2x(BM.45)=4 163.09 150 42.4 BF-0 -1 26.2 1.598 lx(BM.90)=8 12 0.0181 0 175.09 3.2 BF-0 -1 0 1 0.5 45.5 WILKINS95OX BF-I -1 26.2 0 0 11.5197 0 L 0.5 5.8 BF-I -1 0 1 1 150 51.3 2A -1 26.2 1.025 0 0.1577 0 1 0.2 2A -1 5 1 0.75 150 51.5 2-0 -1 31.2 1.025 0 0.2181 0 0.75 0.2 2-0 -1 0 1 0.25 51.6 METER 2-I -1 31.2 0 0 16 0 *** 0.25 4 2-I -1 0 1 17 150 55.6 1 -1 31.2 0.995 0 0.2521 0 171 4.3 1 59.9 Path No: 2 102 20 4.9 13.2 1 lx(BM.Tee-Br)=5 2.6 150 7.2 02 21 13.2 1.101 lx(BM.90)=5 10 0.0313 -0.4 12.6 0.4 02 7.2 Path No: 3 G5 -1 5 1 1x(us.Tee-Br)=6.75 0.5 150 51.4 2A -1 5 1.025 6.75 0.0074 0 7.25 0.1 2A 51.5 File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE_1_2112_462c9c67.sv$ Date 5/27/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 5 Job: 3304 JAMES DRIVE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psi'/2) (gpm) (in) (ft) (ft) (psi) (psi) * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 12.85 ft/s occurs in the following pipe(s): (1-2-I) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE_1_2112_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 6 Job: 3304 JAMES DRIVE Device Graphs Pressure vs. Flow Function Design Area: 1; Supply Ref.: 1; Supply Name:1 4- -- - I ----- -- -- - - 4 ± 5 + 1- 4 1- + 1- I I 4- f . .-----.- ---I-- ii Flow, gpm Pressure Loss Function )esign Ares: 1; BFP Ref.: 113 (WILKINS950XL, Size = 1); Inlet Node: BF-l; Outlet Node: BF-0 P S I oil alip Dm Flow, gpm File: C:Users\derik\AppData\LocaI\Temp\C8141 3303 JAMES DRIVE_1_2112_462c9c67.sv$ Date 5/27/2021 Copyright © 2002-2012 Tyco Fire Protection Products Page 7 5.6- 4.6- Device Graphs Job: 3304 JAMES DRIVE Pressure Loss Function Design Area: 1; Valve Ref.: 112 (RESI-RISER, Size = 1); Inlet Node: $1; Outlet Node: 4-0 0.55-' 6.4 psi @26.2 gpm 5.55 3y 2.55 .- - '35 •-H Lt 0.55 Flow, gpm Pressure Loss Function Design Area: 1; Valve Ref.: 114 (METER, Size = 1); Inlet Node: 24; Outlet Node: 2.0 4ps1 @31.2 gpm V V}V. . fi - _LJt f ft it* fi 4 It T + ft t4 Flow, gpm File: C:\Users\derik'AppData\Local\Temp\C8141 3303 JAMES DRIVE_1_2112_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 8 HYDRAULIC CALCULATIONS for Job Information Project Name: 3304 JAMES DRIVE Contract No. : C8141 City: CARLSBAD, CA 92008 Project Location: 3304 JAMES DRIVE Date: 5/27/2021 Contractor Information - - Name of Contractor: INNOVATIVE FIRE PROTECTION, INC. Address: 8779 COTTONWOOD AVE.,STE. 101 City: SANTEE, CA 92071 Phone Number: 619-593-8200 E-mail: DERIKIIFPINC.NET Name of Designer: DERIK BROOKS Authority Having Jurisdiction: CARLSBAD FIRE AUTHORITY Design Remote Area Name 2 Remote Area Location PRIMARY BEDROOM Occupancy Classification RESIDENTIAL Density (gpmlft2) 0.053 Area of Application (ft2) 400 Coverage per Sprinkler (if2) 400 Number of Calculated Sprinklers 1 In-Rack Demand (gpm) 0 Special Heads Hose Streams (gpm) 5 Total Water Required (incl. Hose Streams) (gpm) 26 Required Pressure at Source (psi) 54.4 Type of System Wet Volume - Entire System (gal) 22.4 gal Water Supply Information 5/20/2021 Date Location SITE Source Notes File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE _1_21 12_462c9c67.sV$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 1 11 Supply 1: 1 Flow (gpm) Pressure (psi) 0 66.6 500 61 Supply Analysis Job: 3304 JAMES DRIVE Hydraulic Analysis for: 2 Calculation Info Calculation Mode Demand Hydraulic Model Hazen-Williams Fluid Name Water © 60F (15.6C) Fluid Weight, (lb/ft3) N/A for Hazen-Williams calculation. Fluid Dynamic Viscosity, (lb•s/ft2) N/A for Hazen-Williams calculation. Water Supply Parameters I Static Pressure I Residual Flow I Available I I I Total Demand I Required Pressure Node at Source I (psi) Pressure I (gpm) I Pressure I (gpm) I (psi) (psi) I (psi) I I 1 66.6 61 500 66.6 26 54.4 Hoses Inside Hose Flow / Standpipe Demand (gpm) 5 Outside Hose Flow (gpm) 0 Additional Outside Hose Flow (gpm) Other (custom defined) Hose Flow (gpm) 0 Total Hose Flow (gpm) 5 Sprinklers -- Ovehead Sprinkler Flow (gpm) 21 InRack Sprinkler Flow (gpm) 0 Other (custom defined) Sprinkler Flow (gpm) 0 Total Sprinkler Flow (gpm) 21 Other Required Margin of Safety (psi) 0 1 -Pressure (psi) 54.4 1 - Flow (gpm) 26 Demand w/o System Pump(s) N/A File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE_1_2112_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 2 Job 3304 JAMES DRIVE Hydraulic Analysis for: 2 File: C:\Users\denk\.AppData\Local\Temp\C8141 3303 JAMES DRIVE _1_2112_462c9c67.sv$ Date 5/27/2021 copyright 0 2002-2012 Tyco Fire Protection Products Page 3 Job: 3304 JAMES DRIVE Hydraulic Analysis for: 2 Graph Labels Label Description Values Flow (gpm) Pressure (psi) Si Supply point #1 - Static 0 66.6 S2 Supply point #2 - Residual 500 61 Di Elevation Pressure 0 4.3 D2 System Demand 26 54.4 Curve Intersections & Safety Margins Curve Name Intersection I I Safety Margin Pressure (psi) Flow (gpm) I Pressure (psi) I © Flow (gpm) Supply 66.6 29.3 12.2 26 Open Heads Required ___________ Calculated Head Ref. Head Type Coverage K-Factor Density Flow Pressure Density Flow Pressure (ft2) (gpm/p5i½) (gpm/ft2) (gpm) (psi) (gpm/ft2) (gpm) (psi) 195 Overhead Sprinkler 400 4.9 0.05 20 18.4 0.053 21 18.4 File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE_1_21 12_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 4 Job: 3304 JAMES DRIVE Hydraulic Calculations PIPE INFORMATION Node 1 Elev 1 K-Factor 1 Flow added (q) Nominal ID Fittings L C Factor total (Pt) Node 2 Elev 2 K-Factor 2 Total flow (Q) Actual ID quantity x (name) = length F Pf per ft elev (Pe) NOTES T frict (Pf) (ft) (gpm/psit/2) (gpm) (in) (ft) (ft) (psi) (psi) Path No: I 195 9 4.9 21 1 6x(BM.90)=30 89.05 150 18.4 4-0 4.54 21 1.101 5x(BM.Tee-Br)=25 66 0.0743 1.9 11x(BM.Tee-Run)=11 155.05 11.5 4-0 4.54 0 1 1.08 31.9 RESI-RISER 4-1 3.46 21 0 0 4.0472 0.5 *** 1.08 4.4 4-1 3.46 0 1 1.46 150 36.7 3 2 21 1.101 0 0.0743 0.6 1.46 0.1 3 2 0 1 lx(us.90)=2.7 4 150 37.4 3A -1 21 1.025 2.7 0.1053 1.3 6.7 0.7 3A -1 0 1.5 2x(BM.45)=4 163.09 150 39.5 BF-O -1 21 1.598 lx(BM.90)=8 12 0.0121 0 175.09 2.1 BF-O -1 0 1 0.5 41.6 WILKINS95OX BF-I -1 21 0 0 11.0872 0 L 0.5 5.5 *** BF-I -1 0 1 1 150 47.1 2A -1 21 1.025 0 0.1053 0 1 0.1 2A -1 5 1 0.75 150 47.2 2-0 -1 26 1.025 0 0.1563 0 0.75 0.1 2-0 -1 0 1 0.25 47.3 METER 2-1 -1 26 0 0 16.0047 0 " 0.25 4 2-I -1 0 1 17 150 51.3 1 -1 26 0.995 0 0.1806 0 17 3.1 1 54.4 Path No: 2 G5 -1 5 1 lx(us.Tee-Br)=6.75 0.5 150 47.2 2A -1 5 1.025 6.75 0.0074 0 7.25 0.1 2A 47.2 * Pressures are balanced to a high degree of accuracy. Values may vary by 0.1 psi due to display rounding. * Maximum Velocity of 10.74 ft/s occurs in the following pipe(s): (1-2-I) *** Device pressure loss (gain in the case of pumps) is calculated from the device's curve. If the device curve is printed with this report, it will appear below. The length of the device as shown in the table above comes from the CAD drawing. The friction loss per unit of length is calculated based upon the length and the curve-based loss/gain value. Internal ID and C Factor values are irrelevant as the device is not represented as an addition to any pipe, but is an individual item whose loss/gain is based solely on the curve data. File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE _1_21 12_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 5 Job: 3304 JAMES DRIVE Device Graphs Pressure vs. Flow Function Design Area: 2; Supply Ref.: 1; Supply Name:1 70 .1- t t 30-1 1 25± 20 $ . -- 54. . C . .. . 5". Flow, gpm Pressure Loss Function )esign Area: 2; BFP Ref.: 113 (WILKINS950XL, Size = 1); Inlet Node: BF-I; Outlet Node: BF-0 Flow, gpm File: C:Users\derik\AppData\LocaI\Temp\C8141 3303 JAMES DRIVE_1..2112_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 6 Job: 3304 JAMES DRIVE Device Graphs Pressure Loss Function Design Area: 2; Valve Ref.: 112 (RESI-RISER, Size = 1); Inlet Node: 44; Outlet Node: 4-0 0.55 9.3 1 i 1 f. 8.3 . t .1- 7.3 63 .- 5.35 4.5 - - 4. --__._ 1 4.4 psi @21 gpm 3. :: . I3 - 1 Ii Flow, gpm Pressure Loss Function Design Area: 2; Valve Ref.: 114 (METER, Size = 1); Inlet Node: 24; Outlet Node: 2.0 I II .,. t t Uftt11/ ft 4psi @26gpmt± 1- i. J- I , t I I + Flow, gpm File: C:\Users\derik\AppData\Local\Temp\C8141 3303 JAMES DRIVE_1_2112_462c9c67.sv$ Date 5/27/2021 Copyright© 2002-2012 Tyco Fire Protection Products Page 7 SPECIFICATION SUBMITTAL SHEET FEATURES Sizes: U314" U 1" U 1-1/4" U 1-1/2" U 2' Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI 131 .20.1 OPTIONS (Suffixes can be combined) U - with full port QT ball valves (standard) U L - less ball valves U U - with union ball valves U S - with bronze "Y" type strainer U TCU - with test cocks "vertical' up U V - with union swivel elbows (3/4" & 1") 0 OSY - with OS & Y gate valves U FDC - with fire hydrant connection (2" only) U FT - with integral male 450 flare SAE test fitting APPLICATION Designed for installation on potable water lines to protect against both backsiphonage and backpressure of polluted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. STANDARDS COMPLIANCE (All sizes approved horizontal. Vertical approvals as listed below.) ASSES Listed 1015 ( vertical 3/4", 1 1/4", 1 1/2" & 2") IAPMO® Listed (vertical I 114"-2") CSA® Listed (vertical 3/4", 1 1/4", 1 1/2" & 2") AWWA Compliant C510 (vertical 3/4") UL® Classified (less shut-off valves only) C-UL® Classified (less shut-off valves only) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (vertical 3/4") City of Los Angeles Approved (vertical 1-114"-2') NYC MEA 426-89-M VOL 3 MATERIALS Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Internals Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series ACCESSORIES U Repair kit (rubber only) U Thermal expansion tank (Model WXTP) U QT-SET Quick Test Fitting Set U Test Cock Lock (Model TCL24) D tC E DIMENSIONS & WEIGHTS (do not include pkg.) B_________ A G DIMENSIONS (approximate WEIGHT MODEL A UNION B LESS BALL LESS WITH SIZE A BALL C D E F G BALL BALL VALVES VALVES VALVES VALVES T in. in. Immlbsi kg lbs. 3/4 20 111/4 2861 121/2 318 7 178 11/2 38 3 76 31/2 89 3 76 15 38 5 2.3 7 3.2 1 25 121/4 311 137/8 353 7 178 11/2 38 3 76 31/2 89 3 76 17 3/4 45 8 3.6 12 5.4 11/4 32 151/2 419 18 1/2 470 109/16 268 2 51 31/2 89 41/2 114 4 1/21114121 1/2154611617.3 22 10 1 1/2 40 171/8435 191/8 486 109/16 268 2 51 3 1/2 89 4 1/2 114 4 1/21114122 3/415781161 7.3 22 10 2 50 181/4460 20 508 109/16 268 2 51 31/2 89 41/2 114 141/21114125 1/8 16381161 7.3 128 112.7 Page 1 of 2 WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805-238-7100 Fax:805.238-5766 In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone: 905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222.5356) Website: http://www.zurn.com 3.2 6.3 9.5 12.6 15.8 . 103 . U) 69 10 ul co 10 Ix 50 100 150 200 250 °- 15 10 FLOW CHARACTERISTICS MODEL 950XL 3/4, 1", 11/4", 1 1/2" & 2" (STANDARD & METRIC) FLOW RATES (us) FLOW RATES (GPM) 0 Rated Flow (Established by approval agencies) TYPICAL INSTALLATION Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Capacity thruSchedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2 5 7 9 14 3/4" 8 12 17 25 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 52 78 105 167 DIRECTION OF FLOW OUTDOOR INSTALLATION INDOOR INSTALLATION SPECIFICATIONS The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat rings and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be acces- sible for maintenance without removing the device from the line. The Double Check Valve Backflow Preventer shall be a WILKINS Model 950XL. WILKINS a Zurn company, 1747 Commerce Way, Paso Robles, CA 93446 Phone: 805-238-7100 Fax:805-238-5766 IN CANADA: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 11_2 Phone:905-405-8272 Fax:905-405-1292 Product Support Help Line: 877-BACKFLOW (877-222-5356) Website: http://www.zurn.com Page 2 of 2 RESI-RISERTM Pre-assembled, compact fire sprinkler riser unit for residential sprinkler systems B Al 2 I INATIONAL PI FIRE PRODUCTS FEATURES S BENEFITS Manifold is manufactured as a one- piece casting that is air-tested for leaks Raised lettering on both sides allows installation to the right or left and easily identifies the flow direction and test and drain outlet Two mounting legs are molded onto the manifold allowing for a secure right or left anchoring Flow switch has dual SPDT switches and a retard of 0-90 seconds Optional "all-in-one" cost-saving combination pressure relief valve/test and drain valve is available Unique, compact design allows installation within standard frame construction and in tighter spaces TECHNICAL DATA Sizes: 1", 1-1/4", 1-1/2', 2" Style: Thread x thread Riser Body Finish: Cast brass Water Pressure Gauge: 0-300 psi Optional Accessories: 175 psi pressure relief valve/test and drain In accordance with NFPA 13,13R and 13D Flow switch and pressure gauge are UL Listed COMPONENTS DESCRIPTION 1 Manifold body, male thread x male thread 2 Inline check valve, spring-loaded 3 Flow switch with retard 14 Drain valve, with optional pressure relief valve 5 Pressure gauge, 0-300 psi DIMENSIONS DESCRIPTION r 1-1i4" A Height* 13" 13' B Width** 11" 12" C Depth 3-1/2' 3-1/2" - Drain Size 1/2' 1' 1-112 2 13" 13" 12-1/4" 12-3/4' 3-1/2" 3-1/2" ill 1.1 Dimensions include all spacing needed to operate drain valve and remove flow switch cover without check valve **With or without pressure relief valve 02019 National Fire Products 0819 1342881 RESI-RISERTM i I NATIONAL II FIRE PRODUCTS MODEL NUMBERS WITH INLINE WITH SWING WITH PRESSURE WITH CPVC PART # CHECK VALVE CHECK VALVE RELIEF VALVE ADAPTERS SR100-IR4 I SR100-R4 SR100-SR4 .1 SR100-IRR4 I I SR100-SRR4 'I I SR100-IR4-TD 'I I SR100-SR4-TD SR100-IRR4-TD 1 1 1 SR100-RR4-TD I 'I SR100-SRR4-TD low SR125-IR4 I SR125-R4 SR125-SR4 I SR125-IRR4 I I SR125-SRR4 SR125-IR4-TD I I SR125-SR4-TD I I SR125-RR4-TD I I I SR125-RR4-TD I I SR125-SRR4-TD I I I Nw SR150-IR4 .1 SR15O-R4 SR150-SR4 I SR150-IRR4 I I SR150-SRR4 I I SR150-IR4-TD I I SR150-SR4-TD I I SR150-IRR4-TD I I I SR150-RR4-TD I I SR150-SRR4-TD I I I I? SR200-IR4 I SR200-R4 SR200-SR4 I SR200-IRR4 I I SR200-SRR4 I I SR200-IR4-TD I I SR200-SR4-TD I I SR200-IRR4-TD I I I SR200-RR4-TD I I SR200-SRR4-TD I I I 02019 National Fire Products 0819 1342881 I iNATIONAL 'I FIRE PRODUCTS RESI-RISERTM HOW IT WORKS: PRESSURE RELIEF/TEST S DRAIN Normal Position: Relieving pressure Manual Open: Locked closed for Static pressure exceeding 175 psi Drain or flow switch test hydrostatic test PRESSURE LOSS 12 10 8 U) 0 10 20 30 40 50 60 70 Flow (gpm) 1 1-1/4" 1-1/2' 2" 80 90 100 02019 National Fire Products 08191342881 MATERIAL Stainless Steel Stainless Steel Stainless Steel Rubber Brass Brass Teflon' l-1/2 2-1/8" 4" 1-3/4" A 2 2-3/4" 5" 2-3/16" 5- C RESI-RISERTM I IIFPI NATIONAL FIRE PRODUCTS INLINE SPRING CHECK VALVE COMPONENTS DESCRIPTION I Nut 2 Spring Cap 3 Spring q 0-Ring Seat S Clapper, Spring-Loaded S Body 7 Washer DIMENSIONS 11 i-u'r A 1-9/16" 2" B 3-1/4" 3-5/8" C 1-3/16" 1-9/16" 02019 National Fire Products 0819 1342881 tqco® Worldwide www.tyco-fire.com Contacts BLAZEMASTER CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet General Description TYCO CPVC Pipe and Fittings pro- duced by Johnson Controls are designed exclusively for use in wet pipe automatic fire sprinkler systems. The TYCO CPVC Pipe and Fittings are produced from BLAZEMASTER CPVC compound that is a specially developed thermoplastic compound composed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art addi- tives. TYCO CPVC Pipe and Fittings are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapt- ers are available to connect CPVC pipe to metallic piping. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. NOTICE The CPVC Pipe and Fittings produced with BLAZEMASTER CPVC compound described herein must be installed and maintained in compliance with this document and with the applica- ble standards of the NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Technical Data Sizes 3/4 Inch to 3 Inch Maximum Working Pressure 175 psi Approvals UL and C-UL Listed FM Approved LPCB Approved NSF Certified MEA Approved (Refer to Installation Handbook IH-1900 dated April 2016 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) ASTM F439 (Sch. 80) ASTM F1970 Color Orange Installation TYCO CPVC Pipe and Fittings are to be to be installed in accordance with Installation Handbook IH-1900. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Page 1 of 2 AUGUST 2018 TFPI9I5 TFPI9I5 Page 2 of 2 Care and Maintenance TYCO CPVC Pipe and Fittings are to be maintained and serviced in accordance with this section. Before closing a fire protection system control valve for inspection or main- tenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must first be obtained from the proper authorities and all person- nel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central station alarms. The owner is responsible for the inspec- tion, testing, and maintenance of their fire protection system and de-vices in compliance with this document, as well as with the applicable standards of the NATIONAL FIRE PROTECTION ASSO- CIATION (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 02018 Johnson Controls. All rights reserved. All specifications and ether information shown wore current as of document revision dale and are subject to change without notice. NATIONAl. FIRE pRorEcTIow ASSOCIATION and NFPA are registered trademarks of National P1,0 Protection rnosocictlonl BLAZEMASTER Is trodarnort, of The Lcbrfcol Corpororlon Johnson Controls SENJU SPRINKLER CO., LTD. Residential Lead Free Flat Concealed SprinkIer. Pendent. I Model: RC-RES, K-Factor: 4.9, SIN: SS8464 GENERAL DESCRIPTION The Model RC-RES Residential Flat Concealed Sprinklers are automatic sprinklers of the compressed fusible solder type. They are decorative and fast responding. The Cover Plate Assembly hides the Deflector, Heat Responsive Element etc., which is concealed above the ceiling. The cover plate has a fiat profile, and its diameter is extremely small (2-5/8 inch, 68mm). The push-on and/or thread-on, thread-off design of the concealed cover plate assembly allows for easy installation of the cover plate. Therefore, the Model RC-RES should be your first choice when aesthetics is the major consideration for ultimate appeal and unbeatable performance is desired. The Model RC-RES is designed for residential occupancies and is perfect for use in homes, hotels and other living quarters. The Model RC-RES is to be used in wet pipe residential sprinkler systems for One- and Two- Family Dwellings and Manufactured Homes per NFPA 131); wet pipe residential sprinkler systems for Residential Occupancies up to and Including Four Stories in Height per NFPA 13R; or, wet pipe sprinkler systems for the residential portions of any occupancies per NFPA 13. The Model RC-RES has a 4.9 (70.6 LPM/bar112) K-factor that meets the required residential flow rates with minimal residual pressure, which allows for smaller pipe sizes and water supply requirements. For extended installation flexibility, the Model RC-RES provides 1/2 inch (12.8mm) vertical adjustment. This adjustment in installation decreases the need for precise cutting of the pipe that drops to the sprinkler and allows for a perfect fit with a range of pipe lengths. The heat sensitivity and water distribution design of Model RC-RES allows for an increased chance of residents to escape or evacuate in case of a fire. However, residential fire sprinkler systems are not a substitute for fire safety awareness or fire safety construction required by building codes. "Lead Free" is defined in the Reduction of Lead in Drinking Water Act (S.3874) endorsed by AWWA's Water Utility Council, and California Assembly Bill #1953 as having less than or equal to a weighted average of 0.25% lead in wetted surface of pipes, plumbing fittings and fixtures. WARNINGS The Model RC-RES must be installed and maintained in accordance with the rules stated herein as well as in compliance with the applicable standards of the National Fire Protection Association regulations and the standards of any other authorities having jurisdiction. In the event of this condition, consult the authorities having jurisdiction for guidance and approval. Failure to do so may impair the integrity of these devices. It is the responsibility of the installing contractor to provide a copy of this document to the owner or their representative, and in turn, it is the obligation of the owner to provide a copy of this document to a succeeding owner. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any related questions. Document No. U085166 Date . Jul/08/2019 Page : 2 of 8 TECHNICAL DATA Approvals: cULus Listed, NSF-61-G Sprinkler Identification Number (SIN): SS8464 Maximum Working Pressure: 175p5i (12.1bar) Discharge Coefficient (Nominal K-Factor): K4.9 GPMlpsi112 (70.6 LPMlbar1'2) Temperature Rating: 162°F (72°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 140°F (60°C) Cover Plate 175°F (79°C) Sprinkler with 162°F (72°C) Cover Plate 205°F (96°C) Sprinkler with 162°F (72°C) Cover Plate Color Code (Sprinkler) 162°F (72°C): Uncolored 175°F (790C): White 205°F (960C): White Color Code (Cover Plate) 140°F (60°C): No Mark 162°F (72°C): White-Colored Mark Vertical Adjustment: 112 inch (12.8 mm) Cover Plate Finishes: Standard Finishes- White, Ivory, Beige, Brown, Black, Nickel, Wood Grain Custom Finishes- Custom color and custom pattern cover plates are available on special order. Contact a Senju Sprinkler representative with any custom orders. Please see chart on Page 8 for more detail. Physical Characteristics: Ref. Figures 1 and 1-1 OPERATION (65 NDL Marking I Year of Manufacture i-SIN SS8464 -K-factor: 1(4.9 Temperature Rating: I62F/72'C Control No.: 6P37 or 205F/96'C or 115'F/79'C "-" RESSPKR Body (copper Alloy) 6 NSF L 1) Deflector (Phosphorus Bronze) I ) Gasket (PTFE) 2-5/8 (68mm) I i Fusible Metal (Solder) or 3-1/4" (0 83mm) I () Ht Collector (Copper) or 2-5/8"scuare (068mm) (6) Cover Plate Assembly FIGURE 1. Model RC-RES K=4.9 Marking (Deflector) SIN: SS8464 K-factor: 1(4.9 Color Code Temperature Rating 162'F/72'C or 175'F/79'C UL Mark or 205'F/96'C COVER PLATE SPRINKLER (Top view) (Bottom view) FIGURE 1-1. Marking (Color Code) In case of fire, the solder component that holds together the Cover Plate and the Retainer melts. Then the Cover Plate is released at once. As a result, the Deflector drops down to the intended position, Two Heat Collectors are exposed to fire, and when sufficient heat from the fire is reached, internal components of the sprinkler fall apart. This leads to the water flow to be distributed on the affected fire area, (Ref. Figure 2) I _ Normal Condition Cover Plate Operation Sprinkler Operation Water Discharge FIGURE 2. OPERATION PROCESS Me ftoure is for illustrative Purposes only) Document No. U085166 Date Jul/08/2019 Page 3 of 8 DESIGN CRITERIA The herein stated rules for use and installation of Model RC-RES are provided by the manufacturer and must be strictly implemented for safe and full results. NOTES Residential Fire Sprinkler Systems should only be designed and installed by individuals who are completely familiar with automatic sprinkler system design, installation procedures, and techniques. Several criteria may apply to the installation and usage of each sprinkler. Consequently, it is recommended that the sprinkler system designer review and develop a working understanding of the complete list of criteria prior to initiating the design of the sprinkler system. Questions concerning sprinkler installation and usage criteria, which are not covered by the following instructions, should be submitted to your contracted company. Include sketches and technical details, as appropriate. In some instances, the requirements of this document may concern specifications which are more stringent, and which take precedence over those specified in NFPA 13, 13D, 13R, or by the authority having jurisdiction. The Model RC-RES must not be used in applications where the air pressure above the ceiling is greater than that below. Inspect all sprinklers after installation to ensure that both the gap between the cover plate, ceiling and the 6 slots in the cup are open and free from any air flow impediment. The spray from the sprinkler is distributed radially outward and downward from the sprinkler deflector. Consequently, the sprinklers must be located such that there will be no blind spaces shielded from spray by partitions, room dividers, overhangs or other parts of the dwelling structure. The number of sprinklers within each compartment (as defined by NFPA 13, 13D, or 13R) must be kept as few as possible. Do NOT use more sprinklers than necessary to cover a particular space. Use only the Cover Plate provided for the Model RC-RES. The sprinkler must be secured in place by firmly fastening the sprinkler system piping to the structure. If the sprinkler is not properly secured in position, reaction forces resulting from sprinkler operation could alter its orientation and its water distribution pattern. Obstruction to Water Distribution Locations of sprinklers must follow the obstruction rules of NFPA 13, 13D and 13R for Residential Sprinklers. General Service Conditions The Model RC-RES must only be utilized in WET PIPE sprinkler systems. Heat Source Criteria Refer to NFPA 13D, 13R or 13 for the requirements relating to the prevention of possible activation of the Heat Responsive Element of Model RC-RES, due to the exposure of a heat source other than an actual fire. Available Sprinkler Temperature Ratings Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating Maximum Ambient Ceiling Temperature Temperature Rating of the Cover Plate Assembly Ordinary 162°F (72°C) 100°F (38°C) 140°F (60°C) Intermediate 175°F (79°C) 150°F (66°C) 140°F (60°C) 1) Intermediate 175°F (79°C) 150°F (66°C) 162°F (72°C) Intermediate 205°F (96°C) 150°F (66°C) 162°F (72°C) 1) Maximum ambient temperature for the Cover Plate Assembly is 100°F (38°C). Precautionary Warnings for Corrosive Environments Model RC-RES sprinklers should not be installed where they may be subjected to a corrosive environment including the following: Chlorine ion and Chloride environment. Stress corrosion cracking may be caused by exposure to environments with Chlorine ion and Chloride. Exposure to this environment may result in sprinklers operating under Non-Fire conditions or Not Operating when exposed to an actual fire. Sprinkler system piping with Copper. Sprinkler systems should be constructed in compliance with the applicable standards and the requirements for copper piping when copper piping is used in the sprinkler system. (Reference standards NFPA 13, ASTM B813, B828, and CDA (Copper Development Association) - Solder Joint) All residual flux must be removed from the interior and exterior of the copper piping by thoroughly flushing before installation of the Sprinkler Heads. Otherwise, residues of flux may cause corrosion and/or leakage in the sprinkler system. Document No. U085166 Date . Jul/08/2019 Page . 4 of 8 Hydraulic Design Criteria The minimum required sprinkler flow rates for systems designed to NFPA 13D or 13R are given in TABLE A as a function of temperature rating and the maximum allowable coverage area. The sprinkler flow rate is the minimum required discharge from the most hydraulically demanding sprinkler from each of the total number of "design sprinklers" as specified in NFPA 130 or 13R. For systems designed to NFPA 13, the number of designed sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in TABLE A for NFPA 130 and 13R as a function of temperature rating and maximum allowable coverage area. A minimum discharge of 0.1GPM/sq.ft. [4.07LPM/sq.m] over the "design area" comprised of the four most hydraulically demanding sprinklers for the actual coverage area being protected by the four sprinklers. TABLE A. NFPA 13D & 13R WET PIPE HYDRAULIC DESIGN CRITERIA for Model S58464 For systems with ceiling types smooth flat horizontal, or beamed, or sloped, in accordance with NFPA 130, 13R or 13 as applicable. Ordinary Intermediate Intermediate Maximum Maximum Temperature Rating Temperature Rating Temperature Rating Minimum Cover age Area' Spacing 162°F (72°C) 175°F (79°C) 205°F (96°C) Deflector Installation Spacing Ft. x Ft. Ft to Ceiling Type Flow Pressure FIow Ft. Pressure FIow Pressure (mxm) (m) GPM PSI GPM PSI GPM PSI (m) (LPM) (bar) (LPM) (bar) (LPM) (bar) 1202 12 13 7.0 13 7.0 13 7.0 Smooth (3.747) (3.7) (49.2) (0.48) (49.2) (0.48) (49.2) (0.48) Ceilings 3/8to7/8 1414 14 13 7.0 13 7.0 13 7.0 Inches. (4.343) (4.3) (49.2) (0.48) (49.2) (0.48) (49.2) (0.48) Beamed Ceilings 1606 16 13 7.0 13 7.0 perNFPA 13D, 13R Concealed 8 (4.949) 9) (4.9) (49.2) (0.48) - - (49.2) (0.48) or 13 (2.4) Installed in 1808 18 17 12.0 17 12.0 beam (5.5x5.5) (5.5) (64.4) (0.83) - - (64.4) (0.83) 3/8 to 7/8 inches below 0x20 20 21 18.4 21 18.4 bottom of L(6.1x6.1) (6.1) (79.5) (1.27) - - (79.5) (1.27) beam. For coverage area dimensions less than the above mentioned, it needs to use the minimum required flow for the Next Higher Coverage Area listed. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-Factor. Refer to Hydraulic Design Criteria Section for details. Sprinkler Spacing Criteria The minimum spacing between sprinklers is 8 feet (2.4m). The maximum spacing between sprinklers cannot go beyond the coverage area calculated by using the specific hydraulic factors. (Ref. TABLE A) Document No. U085166 Date Jul/08/2019 Page 5 of 8 INSTALLATION The Model RC-RES must be installed in accordance with the following instructions: NOTES Do not use any sprinklers which have been subjected to potential mechanical damage. Do not use any sprinklers which show deformation or cracking in either the Sprinkler or the Protective Cap. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to the sprinklers that could cause improper operation or non-operation. The Protective Cap must remain on the sprinkler during installation. After the installation is completed, the Protective Cap must be removed to place the sprinkler in service. Use a torque of 7 to 14 ftlbs (9.5 to 19.0 Nm) to achieve a 1/2 inch NPT sprinkler joint. If you exceed the recommended maximum torque, this could result in damage to the sprinkler inlet, which may lead to leakage from the sprinkler. Use only NR-H model wrench socket for installation of RC-RES sprinklers. Use of any other wrench or socket is prohibited and may cause damage to the sprinkler. In case of insufficient adjustment in Cover Plate installation, do not try to overly tighten, screw the sprinkler too loosely or make any modification to the cover plate assembly. Readjust the sprinkler fitting for a better fit. Do not rotate the Cap Remover RC to the left with force when placing the two hook arms into place. The installed sprinkler may become loosened, which may cause water leakage. Installing Procedure Step I The installation requirements for the sprinkler are as follows: to be installed only in the pendent position with the waterway perpendicular to the ceiling. Install the sprinkler fitting so that the distance from the face of the fitting to the mounting surface will be nominally 2 inches (50.8mm) as shown in Figure 3. Step 2 With pipe thread sealant applied to the threads, hand tighten the sprinkler into the sprinkler fitting. Then tighten it with the Socket NR-H or Ratchet (3/8" drive) & Socket NR-H Combination (Ref. Figure 4). The teeth of the Socket must fit perfectly with the grooves on the Sprinkler for proper installation (Ref. Figure 4). Step 3 If desired, the Protective Cap may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Protective Cap. Before the installation of the ceiling, the sprinkler installation can be started with a 2-3/8 inch (60mm) diameter clearance hole (Ref. Figure 3). Use the "Vertical Adjustment" indicator on the Protective Cap to check for proper installation height (Ref. Figure 3). Step 4 Use the Cap Remover RC to remove the Protective Cap (Ref. Figure 5), and then push or screw a Cover Plate Assembly on the Cup of the Sprinkler by hand until its flange just has contact with the ceiling (Ref. Figure 6 and Figure 7). Stop tightening the Cover Plate Assembly once the flange has contact with the ceiling. If the ceiling has been lifted from its normal position in the process of tightening the Cover Plate Assembly, readjust the cover plate assembly as necessary. If the flange of the Cover Plate Assembly cannot contact the ceiling sufficiently, readjust the sprinkler fitting as necessary. When properly installed, there is a nominal 1/16 inch (1.6mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 6. Make a Space Here Do Not Ave. 1/4 (8.4mm) [ _N1 Over-Tighten 1.) 1," /8- G roove an the Sprinkler Vertical Protective Cap 91 Tooth an the Socket Socket NR-H n g:7 Ratchet Mounting 2 3/8 (6Ornzri) Surface Ceiling Hole Diameter 1 1 FIGURE 3. INSTALLATION FIGURE 4. RATCHET & SOCKET Document No. U085166 Date : Jul/08/2019 Page :6of8 Sprinkler Head Prow veCep Hook up _ I Cap Remover RC I Pull down Step I Step 2 Step 3 FIGURE 5. PROTECTIVE CAP REMOVAL 1Suace ; Owp Deflector Cover Plate Assembf 8(mm) or 3-1/4 (83mm) or 2-5f8 square (062mm) FIGURE 6. INSTALLATION (COVER PLATE ASSEMBLY) INCORRECTI CORRECT INCORRECTI Document No. U085166 Date Jul/08/2019 Page 7 of 8 CARE AND MAINTENANCE The following instructions must be implemented for the maintenance and service of the Model RC-RES. NOTES Wet pipe sprinkler systems must be maintained at a minimum temperature of 40°F/4°C to prevent freezing and bursting of the pipe and/or sprinklers. Automatic sprinklers are not to be tested with a heat source. Operation of the heat responsive element can result. Absence of a Cover Plate Assembly may delay the response time of the sprinkler in case of a fire. Install the cover plate assembly properly, as shown in Figure 6. Improper installation of the cover plate assembly may cause improper operation or non-operation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted cover plates. Non-factory applied paint may adversely delay or prevent sprinkler operation in case of a fire. Do not puff the Cover Plate. Separation may result. In preparation for maintenance of the fire protection system, permission to close the main control valve must be obtained from the proper authorities, and all affected parties by this action, and must be informed before the maintenance session can commence. Do NOT enclose any sprinklers within drapes, curtains, or valances. Do NOT hang anything from the sprinklers. Do NOT clean the sprinklers with soap and/or water, detergents, ammonia, cleaning fluids, or other chemicals. Remove dust, lint, cobwebs, cocoons, insects, and larvae by gently brushing with a feather duster or gently vacuuming with a soft bristle (i.e., dusting) brush attachment. Exercise suitable safety precautions in the use and storage of highly flammable materials. The rapid rate of fire development and spread of these materials can reduce the ability of the sprinkler system to aid in the control of a fire involving such hazards. Leaking or corroded sprinklers must be replaced. Automatic Sprinklers must be kept in a cool and dry place. Automatic sprinklers must never be physically altered, such as painted, plated, or coated, once shipped from the factory. If the sprinklers have been in any way modified, they must be replaced. Great caution must be applied to prevent damage to the sprinklers at all stages - before, during, and after installation. Damaged units because of dropping, hitting, over-tightening, or wrench slippage, must be replaced. The Model RC-RES must only be replaced with pendent sprinklers which are listed for residential fire protection service and which have the same nominal K-Factor, the same coverage area, and the same or lower flow ratings (as indicated under TABLE A "Hydraulic Design Criteria"). When remodeling, such as by adding false beams or light fixtures or changing the location of compartment walls, first verify that the new construction will not violate the installation requirements of the applicable standards of NFPA. Alter the new construction and/or the sprinkler system to suit the requirements of this document and the applicable NFPA regulations. The owner is responsible for the maintenance of the sprinkler system, including inspection and testing of its compliance with this document, as well as the standards of the National Fire Protection Association (e.g., NFPA 25), and the regulations of any other authorities having jurisdiction. The owner should direct any questions regarding the above rules and regulations to the installing contractors or the sprinkler manufacturer. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with NFPA 25. Limited Warranty For details of warranty, refer to Sales Contract. Document No. U085166 Date : Jul/08/2019 Page : 8 of 8 ORDER PROCEDURE When placing an order, please contact a local distributor with the following information (Model Name, Temperature Rating and Finish). Sprinkler Model: RC-RES (SIN: SS8464, Residential Flat Concealed Sprinkler, Pendent, K4.9, Temperature: 162°F (72°C) or 175°F (79°C) or 205°F (96°C)) Cover Plate Assembly 2-5/8 inch (468mm) or 3-1/4 inch (83mm) or 2-5/8 inch square (068mm), Order Separately from Sprinkler Please refer to the chart below for available sizes, temperature, and finishes. Standard Finishes Custom Finishes White Ivory Beige Brown Black Nickel Copper Wood Grain Custom Color Custom Pattern 2-5/8" Round, 140°F o o - - - - - - o o 3-1/4" Round, 140°F 0 0 0 0 0 0 0 0 0 0 2-5/8" Square, 140°F 0 - - - - - - - 0 0 2-5/8" Round, 162°F 0 - - - - - - - 0 0 3-1/4' Round, 162°F 0 - - - - - - - 0 0 Tools for Installation of Model RC-RES Socket NR-H For use with a 3/8" drive ratchet (not included) Socket NR-H Plastic For use with a 1/2" drive ratchet (not included) Cap Remover RC Document No. U085166 Date Jul/08/2019 1 * Bulletin 135 October 2018 L. Reliable Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed For NFPA 13, NFPA 13R, and NFPA 13D Applications Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model Fl Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The F1 Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Residential Sprinkler Summary Sprinkler Sprinkler Identification Orientation K-Factor gpm/p5i112 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (Ipm/bar112) NPT or 1507-1 ft x ft (m x m) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) Fl Res49 R3516 Pendent 4.9 (71) 1/2 Pendent or Recessed 20 x 20 (6.1 x 6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res30CCP R3511 Pendent 3.0(43) 112 Conical Concealed or Recessed 14 x 14 (4,3 x 4.3) F1Res49 CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or Recessed 20x20(6.1 x6.1) F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20x20(6.1 x6.1) F1Res76 CCP R7618 Pendent 7.6(109) Conical Concealed or Recessed 20x20(6.1 x6.1) Fl Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 20 (4.9 x 6.1) F1Res44 SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20(4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 RA3533 Horizontal Sidewall HSWX 5.8(84) 1/2 Recessed 14 x 26(4.3 x 7.9) www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPT or 1507-1R1/2 V Nominal K-Factor: 3.0 (43 metric) Temperature Ratings / Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications °- Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE ' Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2_(Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res3O Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) lT- DIA. -r Face of fitting I 1 1-15/16° J to finished (49mm) DlA.7 ceiling 1/2" (13mm) _______ +1- 1/4" (6mm) Threads ____________ Sealing Assembly 2-1/4"_ ________ 1 Wrench Flat I tGlass Bulb (57mm) Load Screw 11/4"J L_.... 1-3/4" (44mm) +/- 1/4" (6mm) Deflector (32mm) 2-7/8" (72mm) DIA— Components Dimensions F2 & P/ Recessed Escutcheon Installation Model Fl Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe SystemsM) Maximum Coverage Area Flow gpm (I/mm) ft. x ft.(m x m) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 8(30) 7.0(0.48) 1 t 4 inches (25t0 100 mm) 14 X 14(4.3 X 4.3) 10(38) 11.0(0.76) 15x 15(4.6x4.6) 12(45) 16.0(1.1) 16 x 16 (4.9 x 4.9) 13(49) 18.8(l.3) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 2 of 15 October 2018 www.reliablesprinkler.com Technical Specifications Finishes (See Table N) Style: Pendent and Recessed Pendent Threads: 1/2 NPT or IS07-1R1/2 Temperature Ratings Nominal K-Factor: 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass-bulb Fl Recessed Sprinkler Frame: Brass Alloy Button: Copper Alloy F2 Recessed FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4(57mm) .,_2-1/4 (57mm) 1-15/16 to finished Im _F 4(41 ceiling (49mm) DIA. ceiling Face of fitting DIA. -r Face of fitting +/-3/8"(9mrn) to finished 5/8"(l6mml 1/2(13mm) +1 l/4 (6mm) Ft, 03M 2-1/4 15/8'(4lmm)+/- 1-3I4 (44mm) +1- 1/4 (6mm) /8(9mm) I 1-1/4 - (32mm) 2-7I8 (72mm) DIA 2-7/8 (72mm) DlA. Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 13 (49) 7.0 (0.48) 1 t 4 inches (25 to 100 mm) 14 x 14(4.3 x 4.3) 13(49) 7.0 (0.48) 16 x 16(4.9 x 4.9) 13 (49) 7.0 (0.48) 18 x 18(5.5 x 5,5) 17(64) 12.0 (0.83) 20x20(6.1x6.1) 20(76) 16.7(1.15) 12 x 12 (3.7 x 3.7) 15(57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14 (4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0(0.83) 18 x 18(5.5 x 5.5) 19(72) 15.0(1.03) 20 x 20(6.1 x 6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 3 of 15 October 2018 -._. www.reliab)esprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPTor 1S07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy Fl Recessed Button: Copper Alloy F2 Recessed U J Sealing Assembly: Nickel Alloy with PTFE FV Recessed* Load Screw: Bronze Alloy Deflector: Bronze Alloy Sprinkler Wrenches Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) . 2-1/4" (57mm) DIA. -r Face of fitting 449 J ' Face of fitting DIA, (49mm) DIA. ceiling 1-15/16" to finished to finished 1/2' (13mm) 49mm) DIA. 3/8"(9mm) +/-1/4"(6mm) 5/8' (16mm) ceiling (57) 1-5/8" (4mm) +1- 1-3/4" (44mm) +/- __ -J -1- 2-1/4" 1/4" (6mm) 9mm) 1-1/4' (32mm) 2-7/8" (72mm) DIA. 3/8" ( 2-7/8 (72mm) DIA.—. Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model FlRes58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemsttt Maximum Coverage AreaR ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6(0.52) 1 to 4 inches (2fO1O mm) 18 x 18 (5.5 x 5.5) 19 (72) 10.8 (0.75) 20 x 20(6.1 x 6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 4 of 15 October 2018 ______________ _______________ www.reliablesprinkler.com Technical Specifications Style: Pendent and Recessed Pendent Threads: 3/4' NPT or 1S07-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons Fl Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res76 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4° (57mm 2-1/4' (57mm) V(49DIA,' Face of fitting DIA. Face of fitting to finished 1-15/16' / to finished ceiling (49mm) DIAT7 ceiling 5/8(16mm) J 1/2"(l3mm) +13/8°(9mm) ( +1- 1/4"(6mm) __ 1-5/8° (41 mm) +/- L - 1-3/4°(44rnrn) +1- 3 /8 15/8 I I (44mm) 2-7/8° (72mm) DIA. 2-7/8" (72mm) DIA. Dimensions Fl Recessed Escutcheon Installation F2 & RI Recessed Escutcheon Installation Model Fl Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems'1 Maximum Coverage ArearA Flow Pressure Deflector to ft. x ft. (m x m) gpm (I/mm) psi (bar) Ceiling Distance 18 x 18 (5.5 x 5.5) 21(80) 7.6 (0.52) 1 t 4 inches (25 to 100 mm) 20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Pages of 15 October 2018 www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2' NPTor 1S07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57C)* FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and COP cover plates are not listed for use in positively pressurized ceiling plenums. Model Fl Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions i' l7n,rn1 9/1° lR7mmt ace of fitting to finished ceiling 1/4(32mm) 1/4"(6mm) 15/16" (24mm) ace of fitting to finished ceiling 1/4" (32mm) (- 1/4° (6mm) 1°(25mm) I- 1/4" (6mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model Fl Res3O CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Aream Flow I Pressure Deflector to Ceiling Distance ft. x ft. (mx m) gpm (I/mm) psi (bar) I 12 X 12(3.7 X 3.7) 8(30) 7.0(0.48) 1/2 to 1 inch (13 to 25 mm) 14 x 14(4.3 x 4.3) 11(38) 13.4(0.92) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 6 of 15 October 2018 _____________ __ www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPTor lS07-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)° FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8" (67mm) DIA. 2-5/16" (59mm)DIA. ace of fitting to finished ceiling I I ____________________________________ I Face of fitting to finished ceiling I -1/4" (32mm) Lj-1/4" (32mm) (-1/4"(6mm) +/-1/4"(6mm) (24mm) -.. . +/-1/4"(6mm) L3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation Model F1Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure PS (bar) Deflector to Ceiling Distance 14 x 14 (4.3 x 4.3) 13(49) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 16.7(l.15) 16 X 16(4.9 X 4.9) 14(53) 8.2 (0.57) 18 x 18(5.5 x 5.5) 18(68) 13.5 (0.93) 20 x 20(6.1 x 6.1) 20(76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 7 of 15 October 2018 _______________ www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2' NPT or 1S07-1R1/2 Nominal K-Factor: 5,8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)° FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions f 2-5/8"(67mm) DIA.1 2-5/16" (59mm)DIA. ace of fitting to finished ceiling I I ' I ____________________________________ Face of fitting to finished ceiling I -1/4" (32mm) I 1-1/4" (32mm) /-1/4"(6mm) 1/4" (6mm) (24mm) -.. .+/-1/4"(6rnrn) L3-3/16"(78mm) DIA. FP Recessed Escutcheon Installation Model Fl Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems() Maximum Coverage Area'°' ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6 (0.52) 1/2 to 1 inch (13 to 25 mm) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20 x 20(6.1 x 6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 8 of 15 October 2018 www.reliablesprinkler.com ç!° (7mm\ CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4 NPT or 1S07-1R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model F1Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 2-5/8° (67mm) DIA. 2-5/16 - (59mm)DIA. ace of fitting to finished ceiling _____________________________________ _____________________________________ I Face of fitting to finished ceiling 1/4 (32mm) 1 iII_tI;4:iiIIiiii!i 1-1/4°(32mm) ...... +/- 1/4°(6mm) 1-1/4°(6mm) (24mm) +/-1/4"(6rnm) L3-3/18"(78mm) DIA. FP Recessed Escutcheon Installation Model F1Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Area Flow Pressure Deflector to Ceiling Distance ft. x ft. (mx m) gpm (!/min) psi (bar) 16 x 16(4.9 x 4.9) 21(80) 7.6 (0.52) 1/2t0 1 inch (13 to 25 mm) 10.8 (0.75) 18 x 18 (5.5 x 5.5) 22(83) 8.4 (0.58) 20 x 20(6.1 x 6.1) 25(95) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 9of 15 October 2018 - - www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2' NPT or 1S07-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall o 151 mm' 1/2" (13mm) +1-1/ mm( I V//// (64mm1 2-1/2" T _________ j 1-15/16" (57mm) (49mm) - DA. DIA. Top of Deflector Down from Ceiling to be Either 4" to 6" (100 to l5O mm) 0r6"to 12" (150 to 300 mm) Based on 5/16 Hydraulic Calculations 1/2" (13mm) (8mm) Dimensions F2 & P1 Recessed Escutcheon Installation Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems'" Maximum Coverage Area' ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 12(45) 7.5(0.52) 4 to 6 inches (100 150 mm) 18.7(l.29) 14 x 14(4.3 x 4.3) 14(53) 10.2(0.70) 15 x 15(4.6 x 4.6) 15(57) 11.6(0.80) 16 x 16(4.9 x 4.9) 16(61) 13.3(0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20(4.9 x 6.1) 23(87) 27.4(1.89) 18 x 18(5.5 x 5.5) 19(72) 12 x 12(3.7 x 3.7) 14(53) 10.2(0.7) 6 to 12 inches (15010300mm) 27.4(l.89) 14 x 14(4.3 x 4.3) 16(61) 13.2(0.91) 15 x 15(4.6 X 4.6) 16(61) 13.2(0.91) 16x 16(4.9x4.9) 17(64) 15.0(1.03) 16 x 18 (4.9 x 5.5) 20(76) 20.7(1.43) 16 x 20(4.9 x 6.1) 23(87) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page loofls October 2018 -- www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Sidewall Threads: 1/2 NPT or ISO 7-1 111/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass-bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) (I) Cover Plates SWC SWC Conical Concealed Plate(') SWC-2 (Slotted) Conical Concealed Plate(3) Sprinkler Wrenches Model GFR2 SWC-2 Note: ( for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. 121135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers 3) 135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions iuitI 1-1/4"(32mm) - 2' (51mm) +1- 1/4" (6mm) +1- 1/4 (6mm) Face of fitting to finished wall 2-1/2" (64m7 5/16"] (8mm) 2-5/8" 2-5/16' (67mm) (58mm) DIA _1l Top of Deflector Down from ceiling to be Either 3 5/16" 4" to 6" (100mm to (84mm) 150mm( or 6' to 12" DIA. (150mm to 300mm) I Based on Hydraulic I calculations I 15/8, (41 mm) Dimensions SWC & SWC-2 Concealed Cover Plate Installation Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems ) Maximum Coverage Aream ft. x ft. (m x m) Ordinary Temperature Rating 155°F (88°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance psi (bar) Flow gpm (I/mm) Pressure psi (bar) Flow gpm (I/mm) Pressure 12 x 12 (3.7 x 3.7) 13(49) 8.7 (0.60) 14 (53) 10.2 (0.7) 14 x 14(4.3 x 4.3) 14(53) 10.2 (0.7) 14(53) 10.2 (0.7) 4to6 inches (100 to 150 mm) 15 x 15(4.6 x4.6) 16(61) 13.2 (0.91) -- -- 16 x 16(4.9 x 4.9) 17 (64) 15.0(1.03) - - - - 16x 18(5.5 x 5.5) 19(72) 18.7(l.31) -- -- 16 x 20(4.9 x6.1) 23(87) 27.4(1.89) -- -- 12 x 12(3.7 x 3.7) 14(53) 10.2(0.7) -- -- 6 to 12 inches (150 to 300 mm) 14x 14 (4.3x4.3) 15(57) 11.7 (0.81) -- -- 15 x 15(4.6 x 4.6) 17(64) 15.0(1.03) -- -- 16 x 16 (4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16x 18 (4.9x5.5) 20(76) 20.7(l.43) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 11 of 15 October 2018 _______________ www.reliablesprinkler.com - 1/2"(13mm) Technical Specifications Finishes Style: Sidewall and Recessed Sidewall (See Table N) Threads: 1/2" NPTorlSO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F(79°C) j Material Specifications . -. Thermal Sensor: 3 mm glass bulb Recessed Escutcheons I Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed \ Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model _GFR2_(Recessed) Model Fl Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 2" (51 mm) 1/2" (13mm) +1- 1/4" (6mm) +1- 1/4" (6mm) 1-151 2-1/4" /16 j DIA. (57mm) (49mm) 5/16" (8mm) 1 Top of Deflector Down from - Ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 & FV Recessed Escutcheon Installation Model Fl Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Table L Minimum Flow and Residual Pressure in Wet Pipe Systems' Maximum Coverage Are&2 ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 16(61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 25.0(1.72) 14 x 14 (4.3 x 4.3) 18 (68) 9.7 (0.66) 15 x 15(4.6 x 4.6) 19(72) 10.7 (0.74) 16 x 16(4.9 x 4.9) 21(80) 13.2 (0.91) 16 x 18(5.5 x 5.5) 25(95) 18.6(1.28) 16 x 20 (4.9 x 6.1) 29(110) 12 x 12(3.7 x 3.7) 22(83) 14.4(1.0) 6 to 12 inches (150to300mm) 128.6(1.97) 14 x 14(4.3 x 4.3) 22(83) 14.4(1.0) 15 x 15 (4.6 x 4.6) 24(91) 17.1 (1.18) 16 x 16(4.9 x 4.9) 26(98) 20.1 (1,39) 16 x 18(4.9 x 5.5) 1 31 (117) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 ñiiiIiI. www.reliablesprinkler.com 12 of 15 October 2018 sprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPTor 1507-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 2-1/2 (64mm) 1/2 (13mm) - +1- 1/4" (6mm) +1- 1/4(6mm) 3(76mm) L~-,/Z'(13mm) 5/16 (8mm) 2-1/4 1-15/16" (57mm) (49mm) - DIA. DIA. - Top of Deflector Down From Ceiling to be Either 4" to 6' (100 to 150 mm) or 6" to 12" (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 & P/ Recessed Escutcheon Installation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Aream ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20(5.5 x 6.1) 30(114) 26.8(1.85) 4 to 6 inches (100 to 150 mm) 52.4(3.63) 20x20(6.1 x6,1) 30 (114) 26.8(1.85) 16 x 22 (4.9 x 6.7) 33(125) 32.4 (2.23) 16 x 24 (4.9 x 7.3) 38(144) 42.9 (2.96) 14 x 26 (4.3 x 7.9) 42 (160) 18 x 20(5.5 x 6.1) 35(133) 36.4 (2.51) 6 to 12 inches (150 to 300 mm) 62.9 (4.34) 16 x 22 (4.9 x 6.7) 38 (144) 42.9 (2.96) 16 x 24(4.9 x 7.3) 42(160) 52.4(3.61) 14 x 26(4.3 x 7.9) 46(174) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Page 13 of 15 Bulletin 135 October 2018 www.reliablesprinkler.com Model GFR2 Finishes ji;1Fi Standard Finishes Special Application Finishes SprinklerM Fl, F2. FV FPC ), CCP, SWC (Conical) Sprinkler (1) Fl, F2. FV, FP(', CCP, SWC (Conical) Escutcheons Cover Plates Escutcheons Cover Plates' Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester(') Polyester Polyester(') Polyester -- -- -- Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel -- -- -- PTFE 2 -- -- Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model Fl Res sprinklers. Not all Fl Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models Fl Res Recessed Pendent, Sidewall, Conical Concealed Pendent (COP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model W2 Installation of F1 Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, COP, SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and "Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and 1507-1R1/2: 8-18 ft-lbs (11 —24 N-m) 3/4" NPT and 1507-1 R3/4: 14-20 ft-lbs (19-27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model Fl Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed COP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Bulletin 135 Page 14 of 15 October 2018 www.reliablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or 1507-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) LC) C,) 0 N- 0) 0) 0) 0) 0) 3- Bulletin l35 Page 15of15 October 2018 - www.reliablesprinkler.com it Bulletin 014 March 2019 co C 0 -a 0) a :3- F') 0 -k (0 'Bel iabk 0 Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR Series Quick Response Glass Bulb Sprinklers Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model F1171142, F1FRXLH & F1FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Spilnider Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model El FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSI/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1 425), 0786-CPD-40252 (RA1 475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed PendentjF1jF2 Recessed Concealed Recessed Horizontal Sidewall Pendent PendenfJFP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1FR series sprinklers \ are quick-response automatic sprin- klers with a glass bulb thermal element. Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model El FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model El FR Series sprinklers to apply water to afire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model El FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model FlEA series sprinkler. Model El and E2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model El FR56 Concealed Pendent and Model El FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NEPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model FlEA Series sprinklers must be installed vith the Reliable sprinkler installation wrench identified in the Deign and Installation Information table in this Bulletin. Any cPher wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model El FR Series Recessed sprinklers are to be installed as shown in Fig, 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model El FR56 Concealed Pendent and Model F1ER56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model FlEA Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model El FRS6LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) . 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector! Orientation Nominal Sprinkler Height _____ Installation Wrench SIN Approvals Listings and Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 W2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA 1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA 1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA 1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPCB, VdS, Ec 1,2,3,4 Concealed Pendent 2.25 57 GFR2 RA14141 cULus,VdS,EC 5,6 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC 1,2 3,4 , "Conventional 2.25 57 (Pendent or Upright)" W2 RA1475 LPCB, VdS, EC 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 GFR2 RA14151 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall ( Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 112,319 cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel RIFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1 FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model COP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies Only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the El FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. ° cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9) The Fl FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the Fl FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. Cl Listed and Approved Temperature Ratings Model Deflector! Orientation Ordinary Temp. Classification 100°F (38°C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1 07°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) I Temp. Rating 175°F (79°C) I I Temp. Rating I 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb I Red Bulb I Yellow Bulb I Green Bulb Blue Bulb Pendent cULus Fl FR28 Recessed Pendent cULus I Upright cULus Pendent VdS FIFR40 Recessed Pendent VdS I Pendent cULus FIFR42 Recessed Pendent cULus I Upright cULus Pendent I cULus, ULH I I FIFR42LL Recessed Pendent I I cULus, ULH I Pendent cULus F1FRXLH Recessed Pendent cULus I Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC I Concealed Pendent* cULus I cULus,VdS,EC I cULus I FIFRS6 Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent cULus, ULH I FIFR56LL Recessed Pendent I cULus, ULH I Concealed Pendent* I cULus, ULH I Horizontal Sidewall cULus, FM FIFR56 Recessed Horizontal Sidewall cULus, FM I I FIFRS6 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Deflector! Model Orientation (Fig. I & 3) (Fig. I & 3) (Fig. 2) SIN 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment FIFR28 I Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 FIFR42 Recessed Pendent cULus cULus cULus RA1413 FIFR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 FIFRS6 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS, EC FIFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 F1FRS6 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. CEILING Y2"[12. 7mm ADJUSTMEN? 2 5/16" 0/A. [58.7mm] CUF 19 TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS ----\ Fl ESCUTCHEONj_ 3/4"[l9mm] ADJUSTMENT P2 ESCUTCHEON 1/2"[12.7mm] ADJUSTMENT f - 2 7/4 HOLE 0/4. (5 7.2mm] I 15/76" 0/A _______ [49.2mm] r \ / I (1 1' X 1/2' REDUCER PACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] P2 ESCUTCHEON T MAXIMUM RECESS = 3/4"[l9mm] ~AT / / /// / I MINIMUM RECESS = 3/8"[9.5mm] Fl ESCUTCHEON AT MAXIMUM RECESS 7/8 22.2mm] [3.2mm] AT MINIMUM RECESS = 1-5/8 "[41.3mm] = / F2 ESCUTCHEON AT MAXIMUM RECESS = 1— 1/8"[28. 6mm] AT MINIMUM RECESS = 1-5/8"[4 1.3mm] 2 27/32' 0/A. [72.2mm] Model Fl FR56, El FR561-L, El FR42, El FR40, El FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model El or F2 escutcheon 2 5/8" DIA. [66.7mm] HOLE IN CEILING L=-- I- j 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1— 1/2'[38mm] AT MINIMUM RECESS = 1 "[25.4mm] WUM RECESS = 9/16"[14.3mm] IUM RECESS = 1 "[25.4mm] 31/4"DIA. H Tel Model Fl FR56, El FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/879.5mm] 2 1/4" HOLE DIA. [57.2mm] 1" X 1/2" REDUCER Fl ESCUTCHEON [L AT AAAYIAAIIAA Prri7cc 1-T18734 Q,,,,,,1 - AT MINIMUM RECESS = 2-1/16 "[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[4 1.3mm] u-i/a" AT MINIMUM RECESS = 2-1/16752.4mm] [3.2mm] 1 15/16" DIA.JJJ [49.2mm] : 2 27/32" 0/A. [72.2mm] T (1) 4"-12" [101. 6mm-304.8mm] CEILING TO DEFLECTOR TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON L 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mm] ADJUSTMENT OIJFWK RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model El or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW - - 2 518 " DIA 2 5/16" DIA - ________________ HOLE IN CEILING CUP - r—i ujbvu CEILING 1/2" MAX. COVER ADJUSTMENT I COVER PLATE - ASSEMBLY 5/16" DIA SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017FC01A Fig.4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate 1" x 1/2" REDUCING TEE OR ELBOW _iE:H 2 5/16" 0/A CUP - ri / CEILING 5/16" MAX. COVER ADJUSTMENT COVER PLATE ASSEMBLY SPRINKLER :I:I iTiim i ::_ - 25/8" OIA. ! I HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 3/4" 3 5/16" VIA. CONCEALED, 5/16" ADJUSTMENT O17FCO2A Fig. 5- Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model COP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover plate111 Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated (4)5f White Painted Spec!Pl Application Finishes Sprinkler Escutcheon Cover plate1" Electroless Nickel PTFE7 Electroless Nickel PTFE Bright B rig Brass Bright Brass(') Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint26 Black Paint I Off White Off White (2)(6) Off White I Satin Chrome Chrome Dull Chrome Dull I " Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. 2) cULus Listed only. ( 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers IRA1435 (HSW), 1RA1485(vsw), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load ScrewPintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [F1FR28][F1FR40][F1FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent] [Upright] [Conventional] [Horizontal Sidewall] [Recessed Horizontal Sidewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][lSO 7-R1/2J Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][175°F (79-C)] [200-F (93-C)] [286-F (141°C)] Sprinkler Finish Escutcheon Model: [171][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile CCP 1/2-inch (12.7mm) adjustment][low profile CCP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model Fl FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable...For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800)431-1588 Sales Offices 19 Paper (800) 848-6051 Sales Fax Revision lines indicate updated or new data. nellabili (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/19 P/N 9999970300 STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC -For mounting CPVC pipe to wood Flared edges help protect CPVC Galvanized steel 'Supplied with #10 x I" hex head cap screws 'Complies with the static load requirements of NFPA® 13 Suitable for fire protection installations Eliminates spacers or backup blocks Easy installation SUS top mount _R F Designed to mount CPVC pipe horizontally or vertically to wood or composite wood bottom mount joists with a minimum 3/8" thickness. Can only be used as a guide on top of beam or on vertical piping. May be installed to wood using supplied fastener or into (minimum 18 gauge) steel using two 1/4 x 1 TEK type screws. side mount Provides vertical/lateral restraint and prevents upward movement of the pipe that supplies pendant fire sprinkler below ceiling. All sizes can be used as a restrainer in the bottom position. The 3/4" size only can be used as a restrainer in the top position. Installation: Per NFPA 13, 13R and 13D. (see page two) Fasteners: Wood - 3/4" to 3" CPVC Pipe - wood screw - no pre-drill 3/4" to 2" Copper Pipe - wood screw - no pre-drill 3/4" to 2" Steel Pipe - 1/4" x 1-1/2" lag screw - no pre-drill Steel- 3/4" to 3" CPVC Pipe - 1/4" TEK screw 3/4" to 2" Copper Pipe - 1/4" TEK screw 3/4" to 2" Steel Pipe - 1/4" TEK screw MAX. HANGER NPS SPACING 3/4" 2.69" 3.25" 1 67" 2.94" 3.25" 70' 1-1/4" 3.31" 3.25" 79" 1-1/2" 3.56" 4.5" 82" 1 4.06' 5' 94" For use as a restrainer in all sizes when attached to the bottom of structural wood members. For use as a restrainer in the 3/4 inch size when attached to the top of structural wood members ARGCO MODEL # 2530180 The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the users responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the users responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1.800-854-1015 OR LOG ONTO WWW.ARGCO.COM ARGCg INSTALLATION INSTRUCTIONS STAND-OFF TWO HOLE STRAP NO BLOCK FOR CPVC Designed to mount CPVC pipe to wood or composite wood joists with a minumum 3/8" thickness. 1. Snap strap over CPVC pipe. 2. Squeeze strap back around pipe. Allowing pipe to slide back and forth. 3. Fasten the strap to the wood surface using the two hex head screws provided. NOTE: All sizes can be used as a restrainer in the bottom position. The 3/4" size only can be used as a restrainer in the top position. All safety regulations required by the jobsite must be observed. -Observe all federeal and local safety regulations -Wear safety glasses and hard hat at all times *Be aware of personnel working above and below *Wear gloves to avoid splinters and cuts. *When working above ground be sure the structure will support your weight. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM CPVC PIPE HANGER SUPPORT DOUBLE OFFSET DESIGN AR CO SINCE 1081 Hanger & surge restraint for horizontal CPVC piping when installed on the side of supporting structure. -For mounting CPVC pipe to wood *Flared edges help protect CPVC -Galvanized steel construction 'Supplied with #10 hex head cap screws 'Complies with the static load requirements of NFPA® 13 'Suitable for fire protection installations 'Size Range: 3/4" through 1 Designed to mount CPVC pipe horizontally or vertically to wood or composite wood joists with a minumum 3/8" thickness. Offset edge eliminates abrasion. Installation: Per NFPA 13, 13R and 13D. Install into wood or steel. Slides onto CPVC pipe. 3/4" pipe size I Item #2530181-3/4 1" pipe size I Item #2530181-1 System No. Location Spec Section Paragraph Submitted By Date Approved Date ARGCO.com Updated 4/16/2019 0 ARGCO ARGCO CPVC TWO HOLE STRAP (üj us File VIXH.EX6587 Designed for support or restraint fo piping in either a vertical or horizon- tal position. It can be used on top or bottom of a beam. The edges are flared to provent any damage to the CPVC pipe. It is easily attached using 2 hex head self-threading screws (supplied) HEX HEAD SCREWS Galvanized steel construction SNAP CPVC PIPE INTO HANGER. MOUNT HANGER TO UNDERSIDE OF BEAM WITH SCREWS PROVIDED. MAY ALSO BE USED ON TOP SIDE OF BEAM. part # size 25-30-283 3/4" 25-30-284 1" 25-30-285 1-1/4" 25-30-286 1-1/2" 25-30-287 2" Galvanized steel, supplied with hex slotted screws The information contained herein is produced in good faith and is believed to be reliable but is for guidance only. ARGCO and its agents cannot assume liability or responsibility for results obtained in the use of its product by persons whose methods are outside or beyond our control. It is the user's responsibility to determine the suitability of any of the products, methods of use, or preparation prior to use, mentioned in our literature. It is the user's responsibility to observe and adapt such precautions as may be advisable for the protection of personnel and property in the handling and use of any of our products. FOR MORE INFORMATION CALL ARGCO AT 1-800-854-1015 OR LOG ONTO WWW.ARGCO.COM Side View - For Drawings Below Hanger - Wood Stud Hanger - Metal Stud IAc P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 SIDE MOUNT CPVC - COPPER HANGER SIZE - 3/4" thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - S. 203 - EX 4231, EX 2551 FUNCTION - Hanger on CPVC and Copper pipe. INSTALLATION -Per NFPA 13,13R, 13D and CPVC manufacturers instructions on top or bottom of beam. Space by pipe type SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. in STEEL - mm. 18 GA. 3/4" - 2" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCONproducts have been, or are used. 1/08