Loading...
HomeMy WebLinkAbout3606 HARDING ST; ; FPR2021-0058; Permit(City of Carlsbad LIft1 Print Date: 05/11/2022 Job Address: 3606 HARDING ST, CARLSBAD, CA 92008-5008 Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Alarm Parcel #: Track #: Valuation: $0.00 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2021-0058 Status: Closed - Finaled Applied: 05/24/2021 Issued: 08/31/2021 Finaled Close Out: 05/11/2022 Final Inspection: INSPECTOR: Salcedo, Felix Cheung, Nathaniel Project Title: Description: WINDSOR POINTE HARDING -NEW FIRE ALARM SYSTEM (ADDRESSABLE, 96 DEVICES) FPContractor: EMCOM ELECTRONIC SYSTEMS INC 256 WITH ERSPOON WAY, # STE H EL CAJON, CA 92020-2755 - (619) 667-1200 FEE AMOUNT FIRE New Alarm System $1,265.00 Total Fees: $1,265.00 Total Payments To Date: $1,265.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov i 00 S EMCOM ELECTRONIC SYSTEMS, INC. CALIC. 820216 SEC. LICACO 3838 256 WITHERSPOON WAY, SUITE H • EL CAJON, CA 92020. PH. (619) 667-1200 • FAX (619) 667-1222 I Fire Alarm System Equipment Submittal Windsor Pointe IsI.t:iIs1ti tIIiT1I4 The FX-35C-60-DR'Intelligent Fire Alarm Contro l Panel is a s1rg1e loop addressable panel that supports up to 60 adcressable points. The FX-350-60-DR is equipped with a two line by 20 character backlit LC D display, numerical keypad and an integrated UDACT/ Digital Comnunicator. The LCD display allows fo r 32 characters to be configured for user defined messages. In addition the FX-350 Series family also includes remote LED and LCD annunciators. The FX-350-60-DR is ideal for both new and retrofit applications. Designed for small to medium commercial, iistitutional and industrial occupancies, these panels are powerful enough to meet today's installation demands. The FX-350-60-DR is configurable by the keypad for onsite programming or by a PC for both onsite and remote programmi n g . Easy to install and simple to operate and configure, the FX-350-60-DR enables the installer to configu r e the system to meet their specific requirements. The FX-350-60-DR is equipped with a 5.5 Amp power supply, auxiliary resettabte smoke power supply (300mA max.), an interface for a Remote Troubl e Indicator (RTI-1) and an RS-485 interface for remote LCD and LED annunciators. The FX-350-6C-DR comes complete with a red door, black enclosura, durable CAT-30 lock and key and space to mount up to 12 AH batteries. An optiona l trim ring is available for semi-flush mounting. I I I I I I I LII I I I Description 71 INTELLIGENT FIRE ALARM CONTROL UNIT FX-350-60-DR Features Single Addressable SLC Loop that supports 60 addressable points Points can be any combination of Addressable Sensors or Modules Supports Ionization Sensors, Photoelectric Sensors, Variable Heat Sensors and Multi-Sensor (Heat/Photo) Equipped with a 2 line by 20 character backlit LCD display, numerical keypad and an integrated UDACT/ Digital Communicator LCD display allows for 32 characters to be configured for user defined messages Digital Communicator can be configured for DACT or UDACT mode of operation Configurable via the front panel, PC Configurator, or remote dial up through the built-in modem Sensors can be configured as Alarm, Verified Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only Modules can be configured as Alarm, Latching Supervisory, Non-Latching Supervisory, Water Flow, Monitor, Trouble, Fire Drill Switch, Signal Silence Switch, Aux Disconnect Switch and Buzzer Silence Switch Base panel is equipped with Four Class "B" (Style "B") indicating circuits which may be configured as Class "A" (Style "Z") using a Class "A" signal converter module Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test Subsequent Alarm, Supervisory, and Trouble operation RS-485 Interface for Remote LED and LCD Annunciators Positive Alarm Sequence Interface for a Remote Trouble Indicator (RTl-1) Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5.5 Amp Power Supply Optional City Tie/Polarity Reversal module Optional trim ring for semi-flush mounting MEA approved ty of Ci. go S7010 7165-1477:156 313-97-E Approved for Class lApplications CATALOG NUMBER JU I L t NOT TO BE USED FOR INSTALLATION PURPOSES. ircom reserves the right to make changes at any time wi t h o u t n o t i c e i n prices, colours, materials, components, equipment, spec i f i c a t i o n s a n d m o d e l s a n d a l s o t o rlisr.ntin', Optional Adder Modules OCAC-304 Four Indicating Circuit Class "A" Converter Module The OCAC-304 converts four Class "B" (Style "Y") output circuits on the FX-350 to Class "A" (Style "Z") circuits. The OCAC-304 is equipped with wire leads to connect to the FX-350 main board. Remote Annunciators PR-300 Polarity Reversal/City Tie Module The PR-300 provides outputs for city box and polarity reversal applications. As a city tie module the PR-300 provides an interface between the control panel indicating circuits and a master box. As a polarity reversal module the PR-300 provides an interface between the control panel and a reverse polarity receiver. RAM-300LCDR Remote LCD Annunciator The RAM-300LCDR provides LCD remote annunciation through a 2 line by 20 character LCD display. The RAM- 300LCDR provides control switches for System Reset, Signal Silence, Fire Drill and Acknowledge as well as a numeric keypad to access the menu functions. The common control functions can be disabled on a per function basis. The RAM- 300LCDR has LED indicators forA.C. On, Alarm, Supervisory, Trouble and CPU Fail. The RAM-300LCD comes complete with a red enclosure and a CAT-30 Lock and key. RA-1 000 Series Remote LED Annunciators The RAM-I016TZ and RAM-1032TZ Remote LED Annunciators provide 16 or 32 points respectively of LED annunciation. Both models come standard with bi-coloured LEDs which are automatically configured for either Alarm (Red) or, Supervisory (Amber). The annunciators have indicators forA.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. In addition both models allow for the control switches to be disabled on a per function basis. Both models mount in a BB-I001R enclosure. RAM-208R/RAM-216R Remote LED Annunciators The RAM-208R and RAM-216R provide 8 or 16 points respectively of LED annunciation. Both models feature bi-coloured LEDs which are auto-configurable for eitherAlarm (red) or Supervisory (amber). The LED annunciators have indicators for A.C. On, Common , Trouble and Signal Silence and control switches for System Reset, Signal Silence, Lamp Test and Buzzer Silence. The RAM-208R and RAM-216R are equipped with a keyswitch OR ..i.,_.j which allows for enabling and disabling of the Common Control functions. Both models are available in a red finish and mount in a 4-gang electrical box. Ordering Information Model Description FX-350-60-DR Single Loop 60 Point Intelligent Fire Alarm Control Panel with built-in UDACT/Digital Communicator FA-300TRB Black semi-flush trim ring for FX-350-60-DR enclosure Optional Adder Modules OCAC-304 Four Indicating Circuit Class 'A" Converter Module PR-300 Polarity Reversal/City Tie Module Remote Annunciators RAM-300LCDR Remote LCD Annunciator c/w enclosure. RAM-1016TZ 16 Zone Remote LED Annunciator with trouble LEDs. Mounts in an BB-1000 Series enclosure. RAM-1032TZ 32 Zone Remote LED Annunciator with trouble LEDs. Mounts in an BB-1 000 Series enclosure. BB-1001R Red enclosure for RAM-1 01 6T or RAM-1032TZ Annunciators. Houses 1 module. RAM-208R 8 Zone Remote LED Annunciator RAM-216R 16 Zone Remote LED Annunciator NOT TO BE USED FOR INSTALLATION PURPOSES. 1411111, M i rc o m" Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 66O4113 Distributed by: Web page: http:IIwww.mircom.com Email: mail@mircom.com CAT. 5670 Rev. 4 id • MIX 1O1P . .. .,, ..' .. 77, I ALPHA INTELLIGENT ADDRESSABLE MODULES MIX-100 SERIES TT TTfl Features MIX-100S MIX-box Mircom's Alpha Series Intelligent Addressable Modules are designed to meet a wide range of applications. The monitor and control modules can be used to supervise and activate sounders, strobes, door closers, pull stations, waterflow switches, conventional smoke detectors and more. An eight position dip switch allows for the address setting of the device and the wiring class/style of the devices that are connected to the module. All modules mount in a standard 4" x 4" x 2 1/8" junction box. Intelligent Addressable Priority Monitor Module (MIX-lOOP) The Intelligent Addressable Priority Monitor Module (MIX-100P) provides an address for a group of UL/ ULC Listed normally open (N.O.) initiating devices, such as heat detectors, beam smoke detectors, 4- wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style 0) or Class B (Style B) initiating circuit. The MIX-100P is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-100P has an activated red LED. Designed to meet a wide range of applications For use with the FX-350 Series Fire Alarm Control Panels Fast response time Priority Interrupt feature on monitor modules Monitor modules can be wired as a Class A (Style D) or Class .B (Style B) Each module can be addressed from ito 126 Eight position dip switch for address setting Red light indicator Modules mount in standard 4" junction box Intelligent Addressable Priority Mini-Monitor Module (MIX-101 P) The Intelligent Add ressabIe Priority Mini Monitor Module provides an address for a group of UL/ULC Listed Normally Open (N.O.) initiating devices, such as heat detectors, projected beam smoke detectors, 4-wire smoke detectors, waterflow switches, manual pull stations, etc. wired in a Class A (Style D) or Class B (Style B) initiating circuit. The MIX-1 01 is equipped with a priority interrupt to provide a fast response to emergency conditions. The MIX-1 DIP has an activated red LED. Intelligent Addressable Relay Module (MIX-100R) The IntelligentAddressable Relay Module connects to the same loop as the initiating devices and provides two isolated sets of Form-C contacts to control a variety of normally open or normally closed contact applications cuch as fan operation and door closures. The MIX-i OOR has an activated red LED which follows the state of the relay contacts. I S5434 S5434 7150-1477:156 CATALOG NUMBER - s,567%1 I NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and model s a n d a l s o t o d i s c o n t i n u e m o d e l s . Intelligent Addressable Supervised Control Module (MIX-100S) The MIX-100S Control module provides supervised monitoring of wiring to signal devices that require an external power supply to operate, such as horns, strobes, bells or speaker isolators. Conventional signals will require a 24 VDC power source and speakers will require an audio input. The red LED will illuminate when the module is activated. The module is capable of Class A (Style Z) or Class B (Style Y) supervision. Specifications General Specifications I Operating Voltage 16-28 VDC Communication Class A (Style D) or Class B (Style B) switch selectable Relative Humidity 0% to 95% (No condensation or icing) MIX-100P and MIX-101P Current Consumption 600 pA Alarm Current 4.6 mA (LED on) Dimensions MIX-loop 4.0"Wx4.0"Hx1.3"D MIX-101P 3.0"Wx2.0"HxO.75"D Weight MIX-100P 3.0 oz. (85.8g) MIX-101P 1.5 oz. (42.6g.) MIX-100S Current Consumption 1 mA Source Power, Signals 24 VDC regulated Speakers 70.7 V RMS Ratings 2A@ 30VDC, 0.6A@ 125VAC Dimensions 4.0W x 4.0" H x 1.3" D Weight 3.0 oz. (85.8g) Fault Isolator Module (MIX-100X) The MIX-100X Fault Isolator Module is used to protect the system against wire-to-wire short circuits on the analog loop. The modules should be spaced between groups of sensors or modules in a loop to protect the rest of the loop. In the event of a short circuit between any two fault isolator modules, both modules immediately switch to an open circuit condition and isolate any group of sensors between them. The remaining units on the circuit will continue to operate in a normal fashion (must be wired in Class A or Style 6). Operating Temperature 0°F to +155°F (-20°C to +70°C) Housing/Cover Plate Finish White Polycarbonate MIX-100X Current Consumption 35pA at 24V Max. Line Current 1 Amp Line Resistance 0.2 ohm Dimensions 4.0" W x 4.0" H x 1.3" D Weight 3.0 oz. (85.8g) MIX-I OOR Current Consumption 250 pA Ratings 2A@ 24VDc, 0.5A@ 30VAC Dimensions 4.0W x 4.0° H x 1.3" D Weight 3.0 oz. (85.8g) Ordering Information Model Description MIX-1 OOP Intelligent Addressable Priority Monitor Module MIX-101P Intelligent Addressable Priority Mini Monitor Module MIX-i OOR Intelligent Addressable Relay Module MIX-100S Intelligent Addressable Supervised Control Module MIX-100x Fault Isolator Module NOT TO BE USED FOR INSTALLATION PURPOSES. IA IVlirc om' Canada 25 Interchange Way Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 Web page: http://www.mircom.com U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Email: mail@mircom.com Distributed by: ISO 9001:2008 f'j\ REGISTERED ''!' CAT. 5675 Rev. 2 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1477:0156 Page 1 of 2 CATEGORY: 7165 -- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin©mircom.com DESIGN: Models FX-350-60-R, FX-350-60-DR FX-350-126-R, FX-350-126-DR, FX-351-LW, *Fx..351LD FX-351 -LDW, FX-353-LDR, FX-353-LDW and FX-350-378-DR fire alarm control units. Local, auxiliary, remote station (PPU), central station (PPU), waterfiow and sprinkler supervisory services. Refer to the listee's data sheet for detailed product description and operational considerations. System components: MD-815; FX-350/FX-351 Mainboard - with Dialer *BBX1O24DS(R);Universal Backbox MD-837; FX-350/FX-351 Mainboard - No Dialer MD-749; DSP Core Board MD-819; Power Supply Board PR-300; City Tie/Polarity Reversal TR-061; 120/240 VAC Transformer CH-613; FX-350 Backbox FX-350 Door FX-350 Deadfront FX-351 Deadfront FX-351 Door FX-351 Backbox MD-825; *Rf,)( 332 RAM-300-LCD; Remote LCD Annunciator MIX-lOOP; Priority Monitor Module MIX-101P; Mini Priority Monitory Module MIX-100S; Supervised Control Module MIX-100R; Addressable Dual Relay Output Module MIX-100X; Isolator Kit *Rev. 11.14-13gt . This the listing is based upon technical data submitted by the test results and/or other data but does not make an applicant. CSFM Fire Engineering staff independent verification of any claims. This has reviewed listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing No. 7165-1477:0156 Page 2 of 2 RATING: 120 VAC, 60Hz 240 VAC, 50 Hz INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances, and in a manner acceptable to the authority having jurisdiction MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as fire alarm control units for use with listee's separately listed electrically and functionally compatible initiating and indicating devices as indicated in design. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. This control panel meets the requirements of UL-864, 9th Edition. I I I I I I LT I I I I I I I I *Rev. 11-14-13gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct ftVC operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division I 1 I I -- ._•i.i•• .t.( •• . ..- •••%•• - ,'.• rfliiAi ç:;J c•;•cli• TG=7FS LTE-A P/N: TG7LAF01 TG7LAFO2 / A A I [E N E \ V C TELGUARD AMETEK COMMERCIAL FIRE PRODUCT FEATURES Certified for use on the AT&T LTE network for sunset-free installations. Meets UL 864 requirements for sole, primary or backup path communications. 11- Minimizes false alarms by providing dual paths for self-tests. Falls back to 3G/4G if an LTE network is not available, for extended network coverage. The Telguard TG-7FS LTE-A is the ideal cellular alarm communications solution for commercial fire systems. The TG-7FS LIE-A transmits alarm signals from the fire panel over the digital cellular network to the designated monitoring station. Compliant with the 2019 and earlier editions of NFPA 72, the TG-7FS LIE-A can serve as the sole communication path for the fire alarm system. It replaces all of the landlines currently dedicated to the master control unit. On average, cellular monitoring costs the end user significantly less than a dedicated landline. For each landline replaced with a TG-7FS LTE-A, the monthly communications bill decreases. By being able to signal failures to the central station within sixty minutes of an outage, the TG-7FS LIE-A can be installed as the sole path for commercial fire installations. For existing installations, all landlines can be swapped for a single TG-7FS LIE-A because of the new five or sixty minute supervision modes. The TG-7FS LIE-A can also be installed as a backup path and upgraded to sole path at a later date. --*--.----. .- k- • ' ., - . -.: U'J . - -. I 1 TG-7FS L U i TELGUARD LTE-A FOP I.- FE- NETVVO .. AMETEK I @1)) I -'-ç I.— mP I jjy A I PG SF5 (I Cenvalst t Fw. 1 L (Opt I) ;€1:( I j Telguard technology allows full data reporting for unlimited point-to-point signal details and maximum transmitting power for I i superior in building penetration Telguard products are easy to install, economical, and UL Listed. I • — -.L.LJt.$J Accessories j I ' TGPEM Power & Expansion Module for powering the TG-7FS I o from 24V DC alarm panel; no need to have an electrician install a dedicated outlet. ' ...-. • ACD 12, ACD 35, ACD 50, ACD 100: 12/35/50/100 feet of low loss, high performance cable. HGD-0: High gain directional antenna. EXD-0: External antenna. I I UL Listings I . . . . commercial Fire commercial Burglary Residential -. .. 864 • Control units & 365 • Police Station 985 • Household fire -. - _ __•• . accessories for fire connected burglar warning systems alarm systems alarm units and 1023 • Household burglar I systems alarm systems 1610 • Central station burglar 4 alarm units; Line security servcies ID '12L ?'-tic ULC Listings I t 1 S545 • Canadian household fire warning systems O IiII - S304 • Canadian commercial burglary alarm systems S559 • Equipment for fire signal receiving centres and systems C0123 • Canadian household burglary alarm systems For the most current product specifications and UL Listings visit www.leiguard.com. SECURITY ii SIGNALING I ( L'hJ •. ELECTRONIC . - us NFP Executive Siiaisy.c rDitii Connected LISTED INTERNATIONAL Gold by AT&T Teiguard, a Division of Telular Corporation 3225 Cumberland Blvd SE • Suite 300 • Atlanta, GA 30339 • USA 800.229.2326 1 teiguard.com o Copyright ©2019 Teiguard, a Business Unit of AMETEK, Inc. • All Rights Reserved I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1402:0109 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: TELULAR CORP.3225 Cumberland Blvd, Suite 300, Atlanta, GA 30339 Contact: Tim Masters (678) 264-2012 Fax (678) 264-2062 Email: Tim.Masters@ametek.com DESIGN: Models TG7LM02, TG7LA001, TG.7LAA01, TG7LA002, TG7LAF01, TG7LAF02, *TG7UBLA and TGKITLA2 digital cellular radio alarm transmission system for fire/burglar alarm system control units. Models TG7LAA02 and TG7LA002 are household application. Model TG7LAF01, TG7LAF02, and TGKITLA2 are for commercial application. Refer to listee's printed data sheet for additional detailed product description and operational considerations INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as digital cellular radio alarm transmission devices to provide a standalone transmission path (cellular) for a listed compatible fire and burglar alarm control unit. It may also provide a backup communication path when used in conjunction with a DACT. This product is to be connected to a listed control panel in accordance with the installation instructions provided by the manufacturer. NOTE: Burglary and other non-fire functions were not examined. I I I I I * Revised 11-27-19gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an an endorsement or recommendation of the item listed. independent verification This listing should of any claims. This listing is not not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. I Fire Engineering Division I I FireS witchi 08 A l t ro n IX Managed NAC Power Extender Overview Rev. DSFireSwitch 10802082013 I The Altronix FireSwitch108 is a cost effective managed NAC Power Extender. It interfaces with 12 or 24VDC Fire Alarm Control Panels (FACP) to provide Notification Appliance Circuit expansion support, for additional horns/strobes to allow ADA compliancy. It also pro- vides auxiliary power to support system accessories It delivers electronically regulated and I filtered 24VDC power to Class B or Class A NAC loop circuits. Additionally, a separate I amp - auxiliary output for 4-wire smoke detectors is available. Alarm current can be divided between the eight (8) outputs for powering NAC devices. Outputs are rated at 2.5 amp max., and can I : be independently programmed for Steady, Temporal Code 3 or Strobe Synchronization. All outputs may be programmed for Input to Output Follower Mode FireSwitch1O8 ' (output will follow input i.e. March Time Input, March Time Output). In non-alarm condition independent loop supervision I for Class A and/or Class B FACP NAC circuits is provided. In the event of a loop trouble, the FACP will be notified via the steered input (input 1 or input 2). In addition, there are common trouble output terminals [NC, C, NO] which are used to indicate general loop/system trouble. Two (2) FACP signaling outputs can be employed and directed to I control supervision and power delivery to any combination of the eight (8) outputs. It provides a programmable LCD display interface, plus an ethernet port interface for remote programmability and monitoring. Specifi Input: Power input: 120VAC 60Hz, 4.8 amp. Two (2) Class A or two (2) Class B FACP inputs. Two (2) configurable inputs trigger via Class A or Class B FACP signal circuits (polarity reversal) or dry contacts. Output: 24VDC voltage regulated power-limited NAC outputs. Output power: 10 amp max. total alarm current. 7 amp max. stand-by without battery back-up. 1 amp with battery back-up including dedicated Aux. output. For Canadian applications Stand-by with battery backup is limited to 0.45 amp. 2.5 amp max current per output. One (1) auxiliary output rated at 1 amp (regulated, battery backed up). 0.45 amp for Canadian applications. Any NAC can be configured as an Aux. output with or without battery back-up (special application only). When set as Aux. output, the output is not supervised. Programmable supervised indicating circuit outputs: Eight (8) Class B or Four (4) Class A, or any combination of Class A and Class B circuits. Thermal and short circuit protection with auto reset. Battery Backup: Built-in charger for sealed lead acid or gel type batteries. Automatic switchover to stand-by battery when AC fails. Zero voltage drop when switching over to battery backup. Supervision. AC fail supervision (form "C" contacts). Battery fail & presence supervision (fomi "C" contacts). Low power shutdown. Shuts down DC output terminals if battery voltage drops below 70-75% for 24V units. Prevents deep battery discharge. cations Special Features: Programmable LCD display interface. Ethernet port interface for remote programmability and monitoring. 2-wire horn/strobe Sync mode allows audible notification appliances (horns) to be silenced while visual notification appliances (strobes) continue to operate. Temporal Code 3, Steady Mode, Input to Output Follower Mode (maintains synchronization of notification appliances circuit). Compatible with 12VDC or 24VDC fire panels. Output loop supervision directed to input 1 or input 2. Common trouble Dry N.C. output for reporting trouble to remote FACP. Ground fault detection - Ground fault maximum test impedance 1,000 ohm. Ground fault Dry N.O. output to report ground fault to remote FACP. Electrical: Operating temperature: 0° C to 49° C ambient. BTU/Hr.: 122.84 BTU/Hr. System AC input VA requirement: 576VA. Visual Indicators: LCD display - Indicates troubles and conditions of operation. Trouble Condition Memory facilitates quick identification of an intermittent/fault (short circuit, open or ground) which has previously occurred on one or more signaling circuit outputs. LCD displays which output the fault has occurred on. Mechanical: Enclosure Dimensions (H x W x D approx.): 15.5" (393.7mm) x 12" (304.8mm) x 4.5" (114.3mm) - Accommodates up to two (2)12VDC/12AH batteries. Product weight (approx.): 12.4 lbs. (5.62 kg). Shipping weight (approx.): 13.7 lbs. (6.21 kg). I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I Agency Approvals UL Listed Control Units and Accessories for NFPA 72 Compliant. L Fire Systems (UL 864). CAN/ULC-S527-99 CSFM - California State Fire Marshal (UII9 Control units for Fire Alarm Systems. 'c,' Approved. Enclosure Dimensions (H x W Li) (approximate): 15.5" (393.7mm) x 12" (304.8mm) x 4.5" (114.3mm) 2.(Y" (50 Sm( 2.0" (50.0rnl 27,O 3 .75rn l27.944 2.25" (3I0.64rnm —i 127.94mm1 91, 14rl I $ fl fl, - - 0.91" I23.114rnl _ ISO (345.7 0 $23 .94nrn0 0.3')' (20.06 $44.45 45" - (1143-,) U 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 00000 0, 0 0 0 0 - -; --:—__- CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7315-1335:0122 Page 1 of 1 CATEGORY: 7315-- POWER UNITS LISTEE: Altronix140 - 58th Street, Bldg A-3W, Brooklyn, NY 11220 Contact: Gary Zatz (718) 567-8181 Fax (718) 567-9056 Email: garyzaltronix.com DESIGN: Model FireSwitch 108 NAC Power Extender designed to provide expanded power capability for up to 8 notification appliance circuits. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 120 V, 60 Hz, 4.8 A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as power supply unit for use with separately listed compatible fire alarm control units for indoor use only. Refer to listee's Installation Instruction Manual for details. I I I I I [I I I I I I I I 01-30-13 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division LI I I Li MS-71 OU Dual Action Manual Station '01 anual Station METAL FIRE ALARM STATION MS-700 SERIES L '':Jfl nh: iFul . Mircom's MS-700 Series Manual Stations provide manual fire reporting. These high quality, die-cast metal manual stations are available in either single or dual action configurations with SPST contacts and terminal strip connections. The normally open contact, which closes when the manual station is activated, is rated for 1 amp, 30 VDC. The contacts are gold plated to avoid the risk of corrosion. The MS-700 Series Manual Stations are available in many different configurations as either single or dual- action devices. The MS-701 is a single action, single stage manual station. Model MS-710 is a single stage, dual action manual station. The MS-702 (two stage) is similar to the MS- 701 (single stage) except it contains an additional General Alarm G.A.) N.O. switch. For safety reasons, the G.A. switcl is only accessible after the handle has been pullec. A special key is supplied with each unit. All models are available with key resets, terminal connectors, SPST gold contacts and CAT-30 lock and keys. The units mount on a standard single gang backbox, Mircom's BB-700 surface metal backbox or BB-700WP weather proof backbox. The MS-700U Series Manual Stations are listed for outdoor applications when used with the BB-700WP. Features Single or Dual Action models Single Stage or Dual Stage models Key resettable Terminal connectors Gold plated SPST contacts Optional auxiliary contacts High-gloss red enamel finish Plastic breakrod Mounts on standard single gang box, Mircom's BB- 700 surface metal backbox or BB-700WP weather proof backbox Available in English and Bilingual versions Operation The MS-700 Series is operated by pulling the handle on the front of the station. The unit is reset by opening the station with the key, placing the handle in the normal upright position and re-locking the station. On the dual action models, the push bar rotates inward allowing the Manual handle to be grasped in a one handed motion. The MS-702 (two stage version) also provides a key switch which is accessible after the handle has been pulled. Operation of the key switch, when connected to a separate general alarm circuit, will initiate the 2nd stage of a two stage alarm signalling system. Specifications The manual station shall be Mircom's MS-700 Series. Operating instructions shall be in raised English or English and French lettering and the unit shall be constructed of high quality die-cast metal and finished in red enamel paint to provide quick identification. Pulling the handle shall initiate immediate operation of the alarm detection circuit. In addition, those stations installed in a two stage system shall come equipped with an internal key switch designed to operate the 2nd stage alarm initiating circuit. All manual fire alarm stations shall be installed to comply with the Canadian Electrical Code (CSA22.1) and CAN/ULC-S524-01 Standard for Installation of Fire Alarm Systems. Final acceptance is subject to the local authority having jurisdiction. ©@';vMEA approved I I I I I I I I S7005 S7005 7150-1477:128 313-97-E CATALOG NUMBER I NOT TO BE USED FOR INSTALLATION PURPOSES. ircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment. specifications and models and also to discontinue models. I I Specifications Switch Rating: Manual Station Dimensions: Colour: Typical Wiring Diagrams I Amp @ 30 VDC, 0.1 Amp @ 125 VAC 4.9" H x 3.5" W x 2.0" D Red with raised white letters, white manual bar with raised black letters. MS-707 and MS-708 SPDT Switch #1 Terminal Block COM NO.- -Re lack White J® L . N.C. SPDT Switch #2 White Keyswitch (MS-708 Model Only) 1 Black ........................... Black NOTES: Wire as shown so that supervision of connections is maintained Mount station to 2" x 4' x 2%" outlet box Maximum size: No. 12AWG For Normally Open operation, cut the NC wire For Normally Closed operation, cut the NO wire Switches shown in the Station Closed position MS-705 and MS-715 SPDT Switch Terminal Block [M Red NC T _T±I___ - White SEE NOTES. NO Switch Surface Mount Backboxes BB-700 Surface Mount Backbox Dimensions: 5" Ft x 3.6" W x 2.0" D BB-700WP Weatherproof Surface Mount Backbox Dimensions: 5" H x 3.6W x 2.2" D I I I I I I I I I I Ordering Information Model Description MS-701 Single Stage Single Action Manual Station (Bilingual) MS-702 Dual Stage Single Action Manual Station (Bilingual) MS-705 Single Stage Single Action Manual Station c/w one additional Form "C" (SPDT) Contact (Bilingual) MS-710 Single Stage Dual Action Manual Station (Bilingual) MS-715 Single Stage Dual Action Manual Station c/w one additional Form C" (SPDT) Contact (Bilingual) Note: Add suffix 'U" for English only models. MS-707 Single Stage Single Action Manual Station c/w 2 Form C" Contacts MS-708 Dual Stage Single Action Manual Station c/w 2 Form "C" Contacts and Key Switch BB-700 Series 700 Interior Surface Mount Backbox, Red Finish BB-700WP Series 700 Weatherproof Surface Mount Backbox, Red Finish NOT TO BE USED FOR INSTALLATION PURPOSES. I I I 1 IMWCOm Canada 25 Interchange Way I Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com SO 9001:2008 f' REGISTERED CAT 5156 Re, 6 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - U FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1477:0128 Page 1 of 1 CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubinimircom.com I DESIGN: Models *Ms..710ApU MS-701U, -703U, 704U, -710U, -713U, -714U, 701ADU, -710ADU, -702U, -702ADU, -701UP, -710UP, -703U(C), -704U(C), -713U(C), -714U(C), -705U, -715U,-706U(C), -716U(C), -707U(C), -717U(C) and -708 fire alarm boxes. These devices are I manually actuated, single or dual action non-coded, fire alarm boxes. Units are to be mounted on standard outlet boxes or listee's Model BB-700 backbox for indoor use only and BB-700WP backbox for indoor and outdoor use. I Models MS- 701 lD(U), -702lD(U) and -7101D(U) non-coded, indoor use only, fire alarm boxes. To be mounted on three-inch deep outlet boxes. I Refer to listee's data sheet for additional detailed product description and operational considerations. I RATING: 30VDC, IA, 125 VAC, 1A INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, rating, and UL label. APPROVAL: Listed as fire alarm manual pull stations for use with separately listed compatible fire alarm I control units. Refer to listee's Installation Instruction Manual for details. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with U California amendments. I I I *Revision 7-19-16 dc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other 1 Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. I Fire Engineering Division Features Low profile design For use with the FX-350 Series Fire Alarm Control Panels Fast response time MIX-3100 Photoelectric Smoke Detector '7 1 4 MIX-3200 -MIX-3300 Multi-Sensor Detector Thermal Detector Description Mircom's Alpha Series Intelligent Addressable Detectors are designed to meet a wide range of applications. The detector's address is set in its base providing a convenient and trouble free maintenance procedure. The detectors mount into a selection of base styles to accommodate installation requirements. Intelligent Photoelectric Smoke Detector (MIX-31 00) The Intelligent photoelectric smoke sensor utilizes a unique optical sensing chamber that is designed to sense smoke produced by a wide range of combustion sources. The photoelectric detector is equipped with a clear LED which flashes when the detector is polled and turns on steady when the detector goes into alarm. Intelligent Multi-Sensor Detector (MIX-3200) The Intelligent Multi-Sensor Detector is a photoelectric smoke detector with a supplementary thermal sensor. The Multi-Sensor detector combines photoelectric smoke and thermal sensor values to provide enhanced detection performance and reduction of false alarms. Information from each sensing element is processed and conditioned by an on-board advanced technology ASIC and digitally Automatic addressing with the MIX-ADD card Variety of mounting bases Ease of installation Elegant, unobtrusive design Digital communications transmitted to the FACP as a single analog value comprised of the combined responses from both the photoelectric smoke and thermal detection elements. Intelligent Thermal Detector (MIX-3300) The Intelligent Thermal Detector utilizes state of the art electronic temperature sense to provide fast and accurate temperature monitoring. The thermal detector features an adjustable termperature range that is configured from the FX-350 Series fire alarm control panel. I I I I I DLC S6295 S6965 7272-1477:131 (MIX-3100 (MIX-3100 (MIX-3100) S MIX-3200) 6 MIX-3200) 7272-1477:142 (MIX-3200) S6299 S7498 7270-1477:139 (MIX-3300) (MIX-3300) (MIX-3300) CATALOG NUMBER 567( I NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. Operating Temperature 0°F to +155°F (-20°C to +70°C) Housing/Cover Plate Finish White Polycarbonate MIX-3200 Multi-Sensor Detector Standby Current 500 pA Alarm Current LED 1 3.5 mA I MIX-ADD Address Card A unique patented addressing method provides simple, user friendly and accurate identification of the detector location. A coded MIX-ADD card is inserted in the base. This can then be read by any Alpha Series detector once it is plugged in. Using this method, all the electronic components are in the detector but the location information is held in the base. The MIX-ADD card simplifies and speeds up installation and commissioning. Addressing errors during maintenance and service are eliminated. I Specifications General Specifications I Operating Voltage 16-28 VDC Communication Class A (Style D) or Class B (Style B) switch selectable I Relative I Humidity 0% to 95% (No condensation or icing) MIX-3100 Photoelectic Detector Standby Current 400 pA Alarm Current LED 3.4 mA MIX-3300 Thermal Detector Standby Current 500 pA Alarm LED Current 3.4 mA Operating Temperature Range 131°F to 194°F (55°C to 90°C) Ordering Information Model Description MIX-3100 Intelligent Addressable Photoelectric Smoke Detector MIX-3200 Intelligent Addressable Multi-Sensor Detector MIX-3300 Intelligent Addressable Thermal Detector MIX-ADD Address Card for MIX-3000 Series Intelligent Detectors I I NOT TO BE USED FOR INSTALLATION PURPOSES. i I/A M go' r com' Canada 25 Interchange Way I Vaughan, Ontario L4K 5W3 Telephone: (905) 660-4655 Fax: (905) 660-4113 U.S.A. 4575 Witmer Industrial Estates Niagara Falls, NY 14305 Toll Free: (888) 660-4655 Fax Toll Free: (888) 660-4113 Distributed Web page: http://www.mircom.com Email: mail@mircom.com SO 9(X) 1:20108 IXJ IIE8ELJ CAT. 5676 Rev. 2 I I Li I Li I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION 2.• OFFICE OF THE STATE FIRE MARSHAL - I FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1477:0131 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR-SYSTEM TYPE-PHOTOELECTRIC LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin@mircom.com I DESIGN: Model MIX-3100 photoelectric smoke detector. Refer to listee's data sheet for additional detailed product description and operational considerations 1 RATING: Electrical: 17 to 28 VDC, 5 to 9V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. I MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a photoelectric smoke detector for use with listee's separately listed compatable fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. I 7300-1477:145). Refer to listee's Installation Instruction Manual for details. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flames. Sources of these fires may include I cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a I grease fire in the kitchen XLF: 7272-1394:0104 I I I I I 04-06-2005 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I the test results and/or other data but does not make an independent verification of any claims. This listing is not 2 an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. I Fire Engineering Division CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-1477:0139 Page 1 of 1 CATEGORY: 7270 -- HEAT DETECTOR LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin@mircom.com DESIGN: Model MIX-3300 combination electronic/fixed temperature heat detector. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Fixed Temperature: 1310-1940 F Electrical: 17 to 28 VDC, 5 to 9 V protocol INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as a heat detector for use with listee's separately listed compatible fire alarm control units and listed Models MIX-2000 Series detector bases (CSFM Listing No. 7300-1477:145). Refer to listee's Installation Instruction Manual for details. XLF: 7270-1394:0105 04-06-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued July 01, 2020 Listing Expires June 30, 2021 I Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division U ALPHA INTELLIGENT MOUNTING BASES MIX-2000 SERIES I Features Low profile design Compatible with Mircom's MIX-2000 Series Intelligent Addressable Detectors Device address is stored in the detector base I I I I I I I I MIX-2000 MIX-2001 Intelligent Mounting Base 6" Intelligent EZ-Fit Base Automatic addressing with the MIX-ADD card Variety of mounting bases Ease of installation Elegant design MIX-2001HT - 6" Intelligent Sounder Base Description MIX-2001R Intelligent Relay Base The MIX-2001 R Intelligent Relay Base is a low prifile 6" mounting base that provides one form C relay contact for control of auxiliary functions such as damper control and elevator recall. MIX-200IHT Intelligent Sounder Base The MIX-2001 HT Intelligent Sounder Base provides a built-in sounder which can be used for evacuation purposes. The MIX-2001 H offers selectable steady or temporal pattern output and selectable high or low volume levels. The sounder base requires an external 24VDC power supply. 0 & @ 7300-1477:145 S6295 S6965 (MIX-2000,M!X-2001 I S MIX-2001R) CATALOG NUMBER 567' I NOT TO BE USED FOR INSTALLATION PURPOSES. Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. .4,'. MIX-2001 R 6" Intelligent Relay Base Mircom's MIX-2000 Series Intelligent Mounting Bases provide a variety of ways to install detectors in any application. The MIX-3000 Series detectors can be mounted in either flanged or flangeless bases depending on the junction box selection. The MIX-ADD address card resides in the mounting base permitting for easy, cost effective detector replacement. MIX-2000 Intelligent Mounting Base The MIX-2000 Intelligent Mounting Base is a standard 4" mounting base with no flange. MIX-2001 Intelligent EZ-Fit Mounting Base The MIX-2001 EZ-Fit Mounting Base is a low profile 6" mounting base with a flange. MIX-ADD Address Card A unique, patented addressing method provides simple, user friendly and accurate identification of the detector location. A coded MIX-ADD card is inserted in the base. This can then be read by any Alpha Series detector once it is plugged in. Using this method, all the electronic components are in the detector but the location information is held in the base. The MIX-ADD card simplifies and speeds up installation and commissioning. Addressing errors during maintenance and service are eliminated. Specifications Base Specifications Diameter 4.0" (102 mm);flangeless 6.0" (150 mm);flange Temperature Range 32°F to 120T (O 'C t049 C) Humidity Range 10% to 93% RH noncondensing Ordering Information MIX-2001 R Electrical Ratings Operating Voltage 17 to 28 VDC Standby Current DmA © 24VDC Alarm Current External Supply: 46mA @ 24VDC Associated Detector: 2mA @ 24VDC Relay Characteristics 1 Form C contact 1.OA © 30 VDC resistive, 0.3A @ 75 VDC resistive, 0.7A @ 50 VAC resistive MIX-2001 HI Electrical Ratings Operating Voltage 17 to 30 VDC (24VDC nominal) Standby Current 0.03mA © 24VDC Alarm Current External Supply: 29mA @ 24VDC Associated Detector. 8mA@24VDC Sound Output High Volume Selection: 85dB @ 10 feet Low Volume Selection: 75dB @10 feet I I I Model Description MIX-2000 4" Intelligent Base (No Flange) clw MIX-ADD card MIX-2001 6" Intelligent EZ-Fit Base c/w MIX-ADD card MIX-2001 R 6" Intelligent Relay Base c/w MIX-ADD card MIX-2001 HT 6" Intelligent Sounder Base c/w MIX-ADD card MIX-ADD Address Card for MIX-2000 Series Bases (Package of 10) I III I NOT TO BE USED FOR INSTALLATION PURPOSES. Distributed by: Mircom Canada U.S.A. 25 Interchange Way 4575 Witmer Industrial Estates I Vaughan, Ontario L4K 5W3 Niagara Falls, NY 14305 Telephone: (905) 660-4655 Tolt Free: (888) 660-4655 Fax: (905) 660-4113 Fax Toll Free: (888) 660-4113 Web page: http://www.mircom.com Email: mail@mircom.com ISO 9OOi:2.IO8 EkED CAT. 5674 Rev. 1 CALIFORNIA DEPARTMENT-OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1477:0145 Page 1 of 1 CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRCOM TECHNOLOGIES, LTD.25 Interchange Way, Vaughan, Ontario L4K 5W3 Canada Contact: Mara Cherubin (888) 660-4655 Ext: 7300 Fax (888) 660-4113 Email: mcherubin©mircom.com DESIGN: Models MIX-2000,'-2001 and -2001 R detector bases. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as smoke detector bases for use with listee's separately listed compatible smoke detectors. Refer to listee's Installation Instruction Manual for details. XLF: 7300-1394:0114 I I I I I I I I I I I I I I 04-06-2005 ry This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division I I I I The L-Series offers the most versatile and easy-to-use line of low frequency sounder and low frequency sounder strobes in the industry. With white and red plastic housings, listed for wall and ceiling mounting, L-Series Low Frequency can meet virtually any application requirement. The low frequency sounder and low frequency sounder strobes were designed to address the NFPA 72 sleeping space requirements that require a low frequency notification appliance that operates within frequency range of 520 Hz ± 10% and is of a square wave tone. Like the entire L-Series product line they include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, L-Series uses a universal mounting plate with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, 24- volt operation, and a rotary switch for 520 Hz low frequency sounder tones, AVDS910-01 • 9/15/2020 • Page 1 Indoor Selectable- Output Low I Frequency Sounders and Low Frequency I Sounder Strobes System Sensor L-Series audible visible notification I products are rich with features guaranteed to maximize profits with lower current draw and modern aesthetics, Features 520 Hz ± 10% square wave tone, NFPA compliance I . Full candela range plus High/Low tone options to optimize current draw for a wide variety of applications I . Compact, standard, and round ceiling options Field-selectable candela settings. Wall units: 15, 30, 75, 95110, 135, and 185. Ceiling units: 15, 30, 75, 95, 115, 150, and 177 I . Rotary switch for High/Low, Temp3, Temp4, and Continuous settings. Sounder-only models also offer a Coded setting. Plug-in design with minimal intrusion into the back box I . Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with legacy SpectrAlert and SpectrAlert I Advance devices (Direct replacement for HW/R-LF and Compatible with MDL3 sync module . Wall and ceiling mount options available Updated modern aesthetics I Agency Listings I . SIGNALING AFPFIOVEC LISTED PR452768 Horns only. 7135-1653:0516 I Horn/Siro0s: 7125-16530517 S401l I I L-Series Specifications General I L-Series low frequency sounder and low frequency sounder strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double-gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting products, The notification appliance circuit wiring shall terminate at the universal mounting plate, Also, L-Series products, when used with the Sync'Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output and I shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit (0°C to 49°C) from a regulated DC or full-wave rectified unfiltered power supply. Low Frequency Sounder strobes shall have field-selectable candela settings. Wall units: 15, 30, 75, 95, 110, 135, and 185. Ceiling units: 15, 30, 75, 95, 115, 150, and 177. The field selectable tones will sound within the I T equency range of 520 Hz ±10% square wave tone and have a permanent marking on the housing that reads "520 Hz". ow Frequency Sounder he low frequency sounder shall be a System Sensor L-Series Model _______ listed to UL 464 and shall be approved for fire protective service. The low frequency sounder and the Sync.CircuitTM MDL3 Module accessory, if used, shall be powered from a notification appliance I circuit output and shall operate on a nominal 24 volts (includes fire alarm panels with built-in sync). When used with the Sync•Circuit Module MOL3, 24-volt rated notification appliance circuit outputs shall operate between 16.5 to 33 volts. If the notification appliances are not UL 9th edition listed with the corresponding panel or power supply being used, then refer to the compatibility listing of the panel to determine maximum devices on a circuit. The low frequency sounder has an option to switch between temporal three or temporal four pattern, non- temporal (continuous) pattern and coded supply within the frequency range of 520 Hz ± 10% square wave tone. The low frequency sounder shall operate on a coded or non-coded power supply with high and low volume settings. Low Frequency Sounder Strobe Combination - The low frequency sounder strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The low frequency sounder strobe shall be wired as a primary-signaling notification appliance and comply with the I Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The sounder shall have an option to switch between a temporal three or temporal four pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The low frequency sounder on low frequency sounder strobe models shall operate on a non-coded power supply with high and low volume settings. I The field selectable tones will sound within the frequency range of 520 Hz ±10% square wave tone. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and low frequency sounder at temporal three. Also, while operating the strobes, the module shall I silence the low frequency sounder on low frequency sounder strobe models over a single pair of wires. The module shall mount to a 4u1/6 x 4 1/16 x 21/8-inch back box. The module shall also control two Class B circuits or one Class A circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. I . Standard Operating Temperature 32°F to 120°F (0°C to 49°C) I Humidity Range io to 93% non-condensing Frequency Range 520 Hz ± 10% Strobe Flash Rate i flash per second Nominal Voltage Low Frequency Sounder Regulated 24 DC/FWR1 I Nominal Voltage Range Low Frequency Sounder Strobe Regulated 24 VDC/FWR Operating Voltage Range 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 16.5 to 33 V (24 V nominal) I Input Terminal Wire Gauge 12 to 18AWG Dimensions Wall Sounder Strobe (including lens) 5.6" Lx 4.7W x 1.9" D (142 mm Lx 119 mm W x 49 mm D) I Ceiling Sounder Strobe (including lens) 6.8" diameter x 2.47" high (173mm diameter x 62.7 mm D) Standard Wall Sounder 5.6 Lx 4.7"W x 1.5' D(142mm Lx 119mmW x 38 mm D) Compact Wall Sounder 5.25" Lx 3.46" W x 1.5" D (133mm Lx 88mm W x 38mm D) I Ceiling Sounder 6.8" diameter 1.4' high (173mm diameter x 36mm high) Standard Wall Sounder with SBBRUSBBWL Surface 5.70" L x 4.8" W x 3.3" D Mount Back Box (145 mm Lx 120 mm W x 87 mm D) Compact Wall Sounder with SBBGRLJSBBGWL Surface 5.4" Lx 3.6" W x 3.0" D (137 mmL x 91mm W x 76 mm D) I Mount Back Box Low Frequency Ceiling Sounder with SBBCRLJSBBCWL 6.9" diameter x 3.9 high (175mm diameter x 99mm high) Surface Mount Back Box I Notes: 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. I AVDS910.01 • 9/15/2020 • Page 2 I I I I I I I I I I I I I I 1 I I I I UL Current Draw and Sound Output Data Sound Current Draw (mA) Output Wall Sounder Strobe dBA Volume 1633VDC 1633 FWR 1633V Pnq Thnp Settinci 1St-d flr-3 7crl qcM 11flM 16rrI 19crI I ISed ficd 75ed 95cd llflcd 135cd 185cd DC FWR 1 Temporal High 115 158 173 182 212 266 136 153 188 206 228 258 304 80 80 2 l3 Low 102 141 162 173 202 255 150 150 176 194 216 242 280 76 76 3 al4 High r141 108 137 151 178 202 252 200 198 169 188 212 242 290 80 80 4 al 4 Low 104 122 136 163 187 237 176 174 154 173 197 227 275 76 76 5 ous High 158 198 216 234 264 305 190 207 249 268 289 321 368 80 80 6 Continuous Low 128 179 196 215 244 285 165 182 226 244 266 297 342 76 76 Sound Current Draw (mA) Output Ceiling Sounder Strobe (dBA) Volume 16-33 VDC 16-33 FWR 16-33 V Pos Tone Settina 1r1 10rei 7M Qc,'rl iind 1rt1 114GM I 1d Rnrd 7d 95cd llflcd 135cd ISSed DC FWR 1 Temporal High 98 115 158 173 197 236 259 136 153 188 206 238 287 291 80 80 2 Temporal 3 Low 98 102 141 162 181 224 244 150 150 176 194 226 269 269 76 76 3 Temporal High 98 108 145 161 186 224 249 200 198 169 189 222 269 277 80 80 4 Temporal 4 Low 102 104 122 136 170 208 227 176 174 154 173 206 252 263 76 76 5 Continuous High 1 141 158 198 216 245 293 295 190 207 249 268 302 357 357 80 80 6 Continuous Low 120 128 179 196 225 271 273 165 182 1 226 244 278 330 330 1 76 76 i. Wall Pos and Ceiling Sounder Volume Tone Setting Current Draw (mA) Sound Output (dSA) Reverberant 16-33 Volts 16-33 Volts DC FWR DC FWR 1 Temporal 3 High 108 150 80 80 2 Temporal 3 Low 78 76 76 76 3 Temporal 4 High 111 151 1 80 80 4 Temporal 4 Low 80 76 76 76 5 Continuous High 111 151 80 80 6 Continuous Low 80 76 76 76 7 Coded High 111 151 80 80 8 Coded Low 80 76 76 76 NU I : I-or coaea tones, temporal cooing must oe provlaea oy tne NAC. If the NAC voltage is held constant, the sounder output will remain constantly on. Coded ratings provided are for continuous voltage. AVD5910-01 • 911512020 • Page 3 Wall LF Sounder Strobe Wall LF Sounder Ceiling/Wall LF Sounder Strobe Ceiling/Wall LF Sounder I I I I I I I I I I I I I I I L-Series Dimensions h 187.81 .91 —J 526 Compact Wall LF Sounder --'- - Red White Low Frequency Sornder Strobes - P2RL-LF _)IS1R_LF Sounder Strobe, Wall - PC2RL-LF PC2WL-LF LF Sounder Strobe, Ceiling/Wall Low Frequency Sounders HRL-LF HWL-LF LF Sounder, Wall HGRL-LF HGWL-LF Compact LF Sounder, Wall HCRL-LFHCWL-LFLFSounder, Ceiling/Wall I Accessories MDL3R MDL3W Sync•CircuitTM Module, UL-listed SBBRL SBBWLSurfaceMount Back Box, Wall SBBCRL SBBCWLSurfaceMountBackBox,Ceili SBBGRL SBBGWLSurfaceMountBackBox,Wall, System Sensor® is a registered trademark and Sync-Circuit" is trademark of Honeywell International, Inc. SYSTEM 3825 Ohio Avenue • St. Charles, IL 60174 -. ©2020 System Sensor. Product specifications subject to change without notice. Visit systemsensor.ceet forcurrent p oduct formation, including the latest version at this data sheet SENSOR" Phone: 800-SENSOR2 • Fax: 630-377-6495 r r AV05910-01 • 9/15/2020 I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7135-1653:0516 Page 1 of 1 CATEGORY: 7135 --AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 Email: megan.sisson@honeywell.com DESIGN: Models HRL-LF, HWL-LF, HCRL-LF, HCWL-LF, HGRL-LF and HGWL-LF are low frequency horns. Horn models HRL-LF, HWL-LF, HGRL-LF and HGWL-LF may be mounted on the wall and are intended for indoor use only unless otherwise indicated. Horn models HCRL-LF, HCWL-LF may be mounted on the ceiling and are intended for indoor use only unless otherwise indicated. The standard horn models are the HRL-LF, HCRL-LF (red enclosure) and HWL-LF, HCWL-LF (white enclosure). The horn has an 8 position selectable tone settings. Models HGRL-LF and HGWL-LF perform the same as HRL-LF/HWL-LF and use a "compact" housing which is intended to mount to a single gang electrical box. Refer to listee's printed data sheet for additional detailed product description and operational considerations RATING: The models HRL-LF, HW-LF, HCRL-LF, HRWL-LF, HGRL-LF and HGWL-LF are rated 16-33 Vdc/VFWR (REGULATED 24 DC/FWR). INSTALLATION: In accordance with the listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, audibility ratings and UL label APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. For indoor dry use. Operating Temperature Range: 0°C to 49°C (32°F to 120°F). Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. I I 1 11 07-01-19 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I I Date Issued: July 01, 2020 Authorized By: DAVID CASTILLO,, M.E., F.P.E. Fire Engineering Division Listing Expires June 30, 2021 ' The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, wall and ceiling mounting options, System Sensor L-Series can meet virtually any ap Dlication requirement. The entire L-Series product line of ceiling-mount strobes and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature a plug-in design with minimal intrusion into the back box, making installations fast and foolproof while virtually elminating costly and time- consuming ground faults. To further simplify installation, the L-Series utilizes a universal mounting plate so installers can mount them to a wide array of back boxes. With an onboard shorting spring, installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using fled-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections, AVDS868-02 • 12/01/2017 • Page 3 I I I Indoor Selectable, Output Strobes and Horn Strobes for Ceiling Applications System Sensor L -Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. 1 Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12- or 24-volt operation at 15 and 30 candela Field-selectable candela settings on ceiling units: 15, 30, 75, 95,115,150, and 177 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and two volume selections Universal mounting plate for ceiling units Mounting plate shorting spring feature checks wiring continuity before device installation Electrically Compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Listed for ceiling mounting only I Agency Listings I SIGNALING > X LISTED APPROVED I S5512 FM approved except 7125-1653d504 S4011 for ALERT models 7135-1653:0503 3057383 I I I I I I I LI I IL-Series Specifications —•----r--T--: I .-'--.-----.--.----.....-.-.----.------- .--- General I L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11/2-inch back box, 4-inch octagon back box, or double- gang back box. Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync.Circuit° Module accessory, shall be powered from a non-coded notification appliance circuit output I and shall operate on a nominal 12 or 24 volts. When used with the Sync.Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 115, 150, and 177. I Strobe The strobe shall be a System Sensor L-Series Model ______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and I associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz Over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync.Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Li Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage . Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Range2 8 to 17.5 V (12 V nominal) or 16to33 V (24 V nominal) Operating Voltage Range (MDL3) 8.5 to 17.5V (12 V nominal) or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions (including lens) 6.8 diameter x 2.5' high (173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9' diameter x 3.4' high (175 mm diameter x 86 mm high) (SBBCRL, SBBCWL) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs P. 5, PC, and SC products will operate at 12 V nominal only for 15 and 30 Cd. I I I I I AVDS868-02 • 12/01/2017 • Page 2 I I Li I I I I I Current Draw Data I UL &-1Z5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC DC FWR Sound Pattern d8 DC DC FWR I Candela 15 87 41 60 Temporal High 39 44 54 Range 30 153 63 86 Temporal Low 28 32 54 75 N/A 111 142 Non-Temporal High 43 47 54 I 95 N/A 134 164 Non-Temporal Low 29 32 54 115 N/A 158 191 3.1 KHz Temporal High 39 41 54 150 N/A 189 228 3.1 KHz Temporal Low 29 32 54 177 N/A 226 264 3.1 KHz Non-Temporal High 42 43 54 I 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3,1 KHz Coded High 42 43 54 I 11 Ti 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd I Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 I Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.lKTemporal High 111 164 69 94 147 163 184 229 257 3.lKTemporal Low 103 163 54 88 143 155 185 212 252 I 3.1K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd I Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 I Non-Temportal Low 78 101 151 172 199 229 262 3.1K Temporal High 108 135 179 200 225 255 289 3.lKTemporal Low 79 101 150 171 196 229 260 3.1K Non-Temporal High 108 135 179 200 225 255 289 3.1K Non-Temporal Low I 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data 8-17.5 16-33 Switch Volts Volts Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 I I AV0S868-02 • 12/01/2017 • Page 3 I I I] I (64 mm) -Q A0546.00 2.47 (62.7 mm) 1.37' (34.8 mm) 6.83 di (173n 6.92k r1im (175. A0545-OO L-Series Dimensions Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box I I I I O1 2-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box 4-Wire Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire, Horn Strobe, Red SCRL Strobe, Red PC2WL 2-Wire, Horn Strobe, White SCWL Strobe, White PC4RL 4-Wire, Horn Strobe, Red SCWL-CLR-ALERT Strobe, White, ALERT PC4WL 4-Wire, Horn Strobe, White Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box, Red SBBCWL Ceiling Surface Mount Back Box, White For a ceiling-listed horn-only device, see AVDS865 "Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications". ' ©2017 System Sensor. —' 3825 Ohio Avenue • St. Charles, IL 60174 SENSOR Phone: 800-SENSOR2 • Fax: 630-377-6495 Product specifications subject to change without notice. Vtsrt systemsensor.ccnr for current product iniorrnahsn, including latest version at this data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION :. OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7i35-16530503 Page 1 of 2 CATEGORY: 7135 - AUDIBLE DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 I Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire and *4 wire Models: HWL, HRL, HOWL and HGRL Horns; I CHWL and CHRL Chimes; P2RL, P2WL, P2GRL, P2GWL, P2RL-P, P2WL-P, P2RL-SP, P2WL-SP, *P4RL and *P4WL Wall H9obes; I PC2RL, PC4RL and *PC4WL Ceiling Horn Strobes; CHSRL and CHSWL Wall Chime Strobes; CHSCRL and CHSCWL Ceiling Chime Strobes; Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR-EV BZR-P, BZR-SP, BZR-PG, - BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZIN-SP, BZW-PO, I BZGR-F, BZGR.-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, I Ceiling Bezel Parts: BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. I Color Lens: LENS-A2, LENS-132, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. WallTrim Rings: *1R2 and *TR2W • CeiiingTrim Rings: *TRC2 and *TRC2W I Wall Surface Mounted Back Boxes: SBBRL, SBBGRL, SBBWL and SBBGWL, I Ceiling Surface Mounted Back Boxes: Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed I V1 the test results and/or other data but does not make an independent verification an endorsement or recommendation of the item listed. This listing should of any claims. This listing is not not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. I Fire Engineering Division Listing No. 7135-1653:0503 Page 2 of 2 SBBCRL and SBBCWL MP120KL 120 VAC Adapter Mounting Plate Refer to listee's data sheet for detailed product description and operational considerations. RATING: 12 VDC regulated and 24 VDCIFWR INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as audible devices when used with separately listed compatible fire alarm control units. Suitable for indoor use, wall or ceiling mounted. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. Revision 08-21-2017 dcc This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. Fire Engineering Division I I I I I I I I I I I I I I I I I I I I CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM I LISTING SERVICE LISTING No. 7125-1653:0504 Page 1 of 2 CATEGORY: 7125 -- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: System Sensor, Unincorporated Div of Honeywell Intl lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Megan Sisson (203) 484-6544 Fax (203) 484-7309 I Email: megan.sissonhoneywell.com DESIGN: System Sensor Indoor 2-wire Models: SRL, SWL, SGRL, SGWL, SRL-P SWL-P, SRL-SP, SWL-CLR-ALERT and SWL-ALERT I Wall Strobes; SCRL, SCWL and SCWL-CLR-ALERT Ceiling Strobes. I Wall Bezel Parts: BZR-F, BZR-AL, BZR-AG, BZR.-EV, BZR-P, BZR-SP, BZR-PG, BZW-F, BZW-AL, BZW-AG, BZW-EV, BZW-P, BZW-SP, BZW-PG, BZGR-F, BZGR-AL, BZGR-AG, BZGR-EV, BZGR-P, BZGR-SP, BZGR-PG, I BZGW-F, BZGW-AL, BZGW-AG, BZGW-EV, BZGW-P, BZGW-SP and BZGW-PG, Ceiling Bezel Parts: I BZRC-F, BZRC-AL, BZRC-AG, BZRC-EV, BZRC-P, BZRC-SP, BZRC-PG, BZWC-F, BZWC-AL, BZWC-AG, BZWC-EV, BZWC-P, BZWC-SP and BZWC-PG. Color Lens: I LENS-A2, LENS-62, LENS-G2, LENS-R2, LENS-AC2, LENS-BC2, LENS-GC2 and LENS-RC2. I WallTrim Rings: TR2 and TR2W I CeilingTrim Rings: TRC2 and TRC2W. Wall Surface Mounted Back Boxes: I SBBRL, SBBGRL, SBBWL and SBBGWL, Ceiling Surface Mounted Back Boxes: I SBBCRL and SBBCWL Refer to listee's data sheet for detailed product description and operational considerations. I *Rev 04-04-19 gt I '- This the test listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other I Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, ME., F.P.E. I Fire Engineering Division Listing No. 7125-1653:0504 Page 2 of 2 I RATING: Regulated 12 VDC setting: 8-17.5 VDC Regulated 24 VDC/fwr setting: 16-33 VDC INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. I APPROVAL: Listed as two wire strobe units used for synchronous application when used with separately listed compatible fire alarm control units. Suitable for indoor use, vertical wall or horizontal ceiling mounted. *Listed with software code, S05-0048-001 for low temperature I compensation. Authority having jurisdiction should be consulted prior to installation. Refer to listee's Installation Instruction Manual for details. I I I I I I I I *Rev 04-04-19 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not I an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2020 Listing Expires June 30, 2021 Authorized By: DAVID CASTILLO,, M.E., F.P.E. I Fire Engineering Division