Loading...
HomeMy WebLinkAbout965 OAK AVE; ; FPR2020-0137; PermititIi.I1T Lay of Carlsbad NN I ~Eiieiaeiimft Print Date: 04/13/2022 Job Address: 965 OAK AVE, CARLSBAD, CA 92008-2419 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2041110200 Track #: Valuation: $3,443,008.17 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2020-0137 Status: Closed - Finaled Underground Fire Applied: 12/17/2020 Issued: 12/28/2020 DEV16005 Finaled Close Out: 04/13/2022 Inspector: Final Inspection: Project Title: CARLSBAD VETERANS HOUSING Description: WINDSOR POINTE OAK -REVISED UNDERGROUND PLANS FOR 24 UNIT APARTMENT COMPLEX Applicant: HA BUILDER GROUP LLC 131 CHAMBERS ST, # STE 101 EL CAJON, CA 92020-4317 (619) 334-3445 FEE AMOUNT FIRE Hourly Services (each additional hour) $149.00 FIRE Hourly Services (first hour) $175.00 FIRE Plan Review Per Hour - Office Hours $136.00 FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $1,216.00 Total Payments To Date: $1,216.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 760-602-8561 f I www.carlsbadca.gov January 8, 2021 Dennis Grubb and Associates D. Grubb 6560 Van Buren Blvd. Ste B Riverside, Ca. 92503 Subject: Construction Change #1 Windsor Point - Oak 965 Oak Avenue Carlsbad, Ca. 92008 The backflow has been changed from the 6" Wilkins 450DA to the 6" Ames Colt C300 DCDA. The fire department connection has been changed from a 2-way to a 4-way F.D.C, Potter Roemer-Model 5436-5. No. 210c 4) CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: Windsor Pointe - Oak SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 965 Oak Avenue CITY: Carlsbad PHONE: (858) 679-2464 (Marie Allen, prolect manager. Affirmed Housing) FAX NUMBER: (858) 679-9076 Largest Building (ft.2): 29,801 sf Sprinkled? yes Construction Type: VA SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CF D . Water Purveyor: City of Carlsbad Location of test (reference map required): Oak Avenue east of Harding St TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 73 PSI Hydrant Number (if applicable): H60775 Elevation of test: 72 Feet Main Size: 8 INCH Pressure Zone: 241 Feet Date/Time of Test: Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 3,000 GPM Residual Pressure 51 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi of 4,225 gpm. However, this exceeds the City's velocity criteria of 10 fps. The required fire flow based on construction type and square fo o t a g e i s 3,000 gpm, which meets the City's pressure and velocity criteria as noted above, and velocity of 9.9 fp s . Note: If the water availability Information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the Information above as applicable and check here: x Name: Jennifer R.Mael,P.E. Eng. Lic. No, (if applicable): C69606 Signature:______________________________________ Title/Org: jEt Manager Date: 12/15/2020 0 ii i Pipe !' iJL 6 "UNL.Legend \ c\ \ 241 330 Fire Flow Test LA N \j Location H60775 - V - V - 16 Project Site - #210 Windsor Point (965 Oak Avenue) - Fire Flow Analysis GENERAL ENGINEERING & PLUMBING CONTRACTOR License: A& C-36 #844070 10149 Channel Road, Suite "A" Lakeside, CA 92040 Phone: (619)561-3337 Fax: (619)561-3732 SUBMITTAL WINDSOR POINTE FIRE WATER DATE: 11-6-20 SUPPLIER: Core & Main, Todd Pipe & Supply PART I - MATERIAL 1.1 PIPE AND FITTINGS C900 DRI4 - Vinyltech Sigma Ductile Iron Push-on Fittings 1.2 BACKFLOWS (A) 6" Ames Cult C300 1.3 FDC CONNECTIONS Potter Roemer Siamese Model 5710 Potter Roemer Swing Check Valve Model 4520 SUBMITFAL REVIEW AME DESIGN GROUP 2601 Main St., Suite 730 Irvine, CA 92614 949.553.0170 []NO EXCEPTION TAKEN E MAKE CORRECTIONS NOTED [1 REVISE AND RESUBMIT DO REVIEWED FOR INFO ONLY H REJECTED Review of this submittal is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Any action shown is subject to the requirements of the plans and specifications. The contractor shall he responsible for: Coordination with that of all other trades and professions in A safe and satisfactory manner, quantities and which shall be confirmed and correlated at the job site; fabrication processes and techniques of construction. By: Ghassan Shreim Date: 11.20.2020 Submittal No: to be reviewed by the Fire sprinkler designer/contractor. Effective 03/14 VINYINECH AWWA C900-07 TECHNICAL DATA SUBMITTAL VINYLTECH VII PVC • PIPE CONFORMANCE These specifications designate the requirements for manufacturing and installing Vinyltech AWWA C900- 07 water pipe. AWWA C900-07 - Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. Through 12 In. (1 00mm Through 300mm), for Water Transmission and Distribution AWWA C605 - Underground Installation of Polyvinyl Chloride (PVC) Pressure Pipe and Fittings for Water ASTM D1784 - Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds ASTM D3139 - Standard Specification for Joints for Plastic Pressure Pipes Using Flexible Elastomeric Seals ASTM F477 - Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe ASTM D2412 - Standard Test Method for Determination of External Loading Characteristics of Plastic Pipe by Parallel-Plate Loading PIPE COMPOUND The pipe shall be extruded from compounds meeting (PVC1120) the requirements of Cell Classification 12454, as defined in ASTM D1784, Standard Specification for Rigid Poly (Vinyl Chloride) (PVC) Compounds and Chlorinated Poly (Vinyl Chloride) (CPVC) Compounds. The PVC shall also be listed by the National Sanitation Foundation (NSF) for use in potable water. PIPE Vinyltech pipe shall be manufactured accordance with AWWA C900-07. GASKET JOINT The gasket shall be reinforced with a steel band and meet the requirements of ASTM F477. Vinyltech pipe shall have an integral bell end with a locked-in factory installed gasket and shall meet the joint requirements of ASTM D3139. MARKING The pipe shall be marked in accordance with AWWA C900 as in the following example. Manufacturer's name and production codes Nominal size, dimension ratio number, and O.D. base (for example, 8" DR 18 CIS) Materials cell classification (PVC1120) AWWA pressure class (235 psi or 305 psi) and hydrostatic test pressure (T600, or T800) AWWA designation number (AWWA C900-07) National Sanitaion Foundation (NSF-61) Underwriters Laboratories (UL) logo, third party certification. Production date and time code (VABB15B 48.34) I) FM Approvals (FM) logo, required FM pressure rating (150 or 200 psi), third party certification QUALITY CONTROL Each length of the pipe including the bell shall be hydrostatically tested. The pipe shall meet all ad- ditional test requirements as described in AWWA C900-07. Our full-time quality assurance staff continually administers a rigid program of tests to maintain the production of the best pipe products available. INSTALLATION Recommended installation procedures of Vinyltech Corporation are outlined in AWWA C605, Underground Installation of Polyvinyl Chloride (PVC) Pressure Pipe and Fittings for Water. The AWWA Manual M23, PVC Pipe- Design and Installation, is also an invaluable resource guide for design and installation. TAPPING The consistent success of tapping PVC pressure pipe is contingent upon the use of proper proce- dures and equipment. Vinyltech recommends strict compliance with the requirements as speci- fied in AWWA C605. ASSEMBLING THE PIPE Assembly of Vinyltech PVC water pipe is easily accomplished. A depth of entry mark is on each spigot end to serve as a visual check for rapid, accurate joint inspection. Do not over insert. Remove any mud, sand, or other foreign matter from the belled and spigot ends of the pipe. Carefully clean the gasket area. With a clean applicator (a brush or hand) lu- bricate the entire surface of the pipe from the spigot end to the depth of entry mark and the contact surface of the gasket with Vinyltech Brand Lubricant. Brace the bell to avoid disturbing the already installed joints. Align the pipe, insert the spigot into the bell and push. Do not insert past the entry mark line. 6\\ `~ *4JU 1 SNYERNATIONAL <s>@APPROVED CERTIFIED TO NSF/ANSI 61 (j) Underwriters Laboratories Inc.® LISTED VTh4YLTECH MEN LIPIPE AN O1TERTAIL COMPANY 201 S. 61st Avenue• Phoenix, AZ 85043 602 233-0071 602 272-4847 Fax www.vtpipe.com VINYLTECH VII PVC • PIPE VINY16TECH AWWA C900-07 TECHNICAL DATA SUBMITTAL C900 NOMINAL SIZE (IN) ,rn DR 18 OUTER DIAMETER (IN) PRESSURE MINIMUM LIFTS PER FEET PER WALL (IN) TRUCK LIFT APPROXIMATE WEIGHT (LB/i 00) 4 (100) 4.800 0.267 16 1020 251.6 6 (150) 6.900 0.383 16 440 521.2 8 (200) 1 9.050 1 0.503 1 20 1 200 1 903.0 10 (250) 11.100 0.617 12 240 1364.4 12 (300) 13.200 0.733 28 60-80 1935.8 NOMINAL SIZE (IN) (rnn) is.- OUTER DIAMETER (IN) MINIMUM LIFTS PER WALL (IN) TRUCK FEET PER LIFT APPROXIMATE WEIGHT (LB/100) 4 (100) 4.800 0.343 16 1020 317.5 6 (150) 6.900 0.493 16 440 658.7 8 (200) 1 9.050 1 0.646 20 1 200 1 1139.7 10 (250) 11.100 0.793 12 240 1722.3 12 (300) 13.200 f-0.943 28 60-80 2445.5 CROSS SECTIONAL VIEW SEALING POINTS THE RIEBER SEALING SYSTEM The Rieber system provides a proven pipe joint with an excellent track record in the field. It is the fastest growing system in the world because of its many advantages. Factory installed, locked-in gasket The pipe bell forms over the gasket, making a perfect fit Avoids the possibility of installing the wrong gasket Reduces installation problems The locked-in gasket eliminates gasket roll-out during joining The gasket is molded vs. extruded and spliced Works equally well under pressure or vacuum Three sealing points achieved vs. two LEAK-PROOF JOINTS "THE WORLDS BEST JOINT" VU'YLTECH MR 201 S. 61st Avenue Phoenix, AZ 85043 AN O1TERTAIL cov PVC-PIPE 602 233-0071 602 272-4847 Fax - www.vtpipe.com >. SIGMA.. Quality - Service - Commitment - Delivered. :©iLIL© 1XJ©llh9 OWA PUM1 iijc • - C110 DUCTILE IRON PUSH-ON FITTINGS BASIC SPECIFICATIONS SIZES: • 411 -2411 MATERIAL: • Ductile Iron ASTM A536, Grade 65-45-12, 60-42-10 or 70-50-05. PRESSURE: • 350 PSI Water Working Pressure 4" - 24" TESTING: • In accordance with ANSI/AWWA C110/A21.10 In accordance with UL - FM requirements. All fittings are hydrostatically tested in accordance with SIGMA Quality Man- agement Standard. All fittings are heat coded to ensure traceability and verification of metallur- gical properties in accordance with SIGMA Quality Management Standards. LAYING LENGTH: • In accordance with ANSI/AWWA C110/A21.10. DEFLECTION: • Up to 5 degrees, in accordance with TYTON JOINT bell design. CEMENT LINING: • Double cement lined in accordance with ANSI/AWWA C104 / A21.4. COATING: • Interior of fitting is seal coated (asphaltic material) in accordance with ANSI AWWA C104/A21.4 and NSF61 approved. Exterior of fitting is seal coated (asphaltic material) in accordance with ANSI! AWWA C110/A21.10 and NSF approved. GASKETS: • Dual hardness SBR in accordance with ANSI/AWWA C111/A2L11. Also available in EPDM, NBR and CR. JOINT: • TYTON JOINT design APPROVALS: • 4"-16" Underwriters Laboratories listed and Factory Mutual Approved. STANDARDS: • Certified to N5F61 Standard including Annex G & 372. ANSI/AWWA C110/A21.10 for Full Body Ductile Iron Push-On Fittings for wa- ter and other liquids. INSTALLATION: • Per ANSI/AWWA C600 and Clii using DIP conforming to C150/C151 and PVC pipe conforming to C900/C905. "._I.i May 2017 SIGMA Corporation www.sigmaco.com I1.2.A I ES-A-C300/C300N Job Name Contractor Job LOCTAN BAR INTENDS TO INSTALL Approval EngineerjIN LIEU OF ZURN MODEL Contractor's P.O. No. - (SEE BELOW) Representative ColtTM Series C300 (Colt 300), C300N (Colt 300N) Double Check Detector Assemblies Sizes: 21/2" - 10" The Colt C300, C300N Double Check Detector Assemblies are designed to protect drinking water supplies from dangerous cross- connections in accordance with national plumbing codes and water authority requirements for non-potable service applications such as irrigation, fire line, or industrial processing. The Colt C300, C300N may be installed under continuous pressure service and may be subjected to backpressure for non-toxic applications. The Colt C300, C300N is used primarily on fire line sprinkler systems when it is necessary to monitor unauthorized use of water. For use in non-health hazard applications. Features Extremely Compact Design 70% Lighter than Traditional Designs 304 (Schedule 40) Stainless Steel Housing & Sleeve Groove Fittings Allow Integral Pipeline Adjustment Patented Tr-Link Check Provides Lowest Pressure Loss Unmatched Ease of Serviceability Available with Grooved Butterfly Valve Shutoffs May be Used for Horizontal, Vertical or N Pattern Installations Replaceable Check Disc Rubber Specifications The Colt C300, C300N Double Check Detector Assemblies shall consist of two independent Tr-Link Check modules within a single housing, sleeve access port, four test cocks and two drip tight shutoff valves. Tr-Link Check shall be removable and serviceable, without the use of special tools. The housing shall be constructed of 304 (Schedule 40) stainless steel pipe with groove end connections. Tr-Link Checks shall have reversible elastomer discs and in operation shall produce drip tight closure against the reverse flow of liquid caused by backpressure or backsiphonage. The bypass assembly shall consist of a meter, which registers in either gallon or cubic measurement, a double check valve assembly and required test cocks. Assembly shall be a Colt C300, C300N as manufactured by the Ames Fire & Waterworks. v.Juuu'-u (Colt 300BF) It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authodty, building and plumbing codes. NOTICE The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. FIRE & WATERWORKS A WATIS Brand Mies Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. I1.2.A I Configurations Horizontal Vertical up N" pattern horizontal Materials Housing & Sleeve: 304 (Schedule 40) Stainless Steel Elastomers: EPDM, Silicone and Buna 'N' Tr-Link Checks: Noryl®, Stainless Steel Check Discs: Reversible Silicone or EPDM Test Cocks: Bronze Body Nickel Plated Pins & Fasteners: 300 Series Stainless Steel Springs: Stainless Steel Available Models Suffix: OSY - UL/FM outside stem and yoke resilient seated gate valves BFG - UL/FM grooved gear operated butterfly valves with tamper switch 5y FxG - Flanged inlet gate connection and grooved outlet gate connection *jy GxF - Grooved inlet gate connection and flanged outlet gate connection Qy GxG - Grooved inlet gate connection and grooved outlet gate connection Available with grooved NRS gate valves - consult factory* Post indicator plate and operating nut available - consult factory* *Consult factory for dimensions Pressure - Temperature Dimensions - Weights Temperature Range: 33°F - 140°F (0.5°C - 60°C) Maximum Working Pressure: 175psi (12.1 bar) C300, 000N SIZE DIMENSIONS WEIGHT IL A in. mm C (OSV) in. mm D in. mm in. G mm H in. mm I in. mm J in. mm P in. mm C300 lbs. kgs C300N lbs. kgs. 21/2 3O/4 781 163/a 416 31/2 89 291/is 738 211/2 546 151/2 393 813A6 223 133A6 335 139 63 147 67 3 313/4 806 18/s 479 3A6 94 301/4 768 221/4 565 17½ 435 9Y16 233 141/2 368 159 72 172 78 4 333/4 857 223/4 578 4 102 33 838 231/2 597 181/2 470 915Aa 252 15Y16 386 175 79 198 90 () (ti/ (1105) (3014 (765) (51h (140) (4434 (1137) (331/i (84 5) 123 (589) 0 31, 032) (19) (483) 309) (140) (350) (1 59) 8 493/4 1264 373/4 959 611A6 170 541/a 1375 401/8 1019 277A6 697 15Wis 399 213/1a 538 494 224 569 258 10 573/4 1467 453/4 1162 8Yis 208 66 1676 491/2 1257 321/2 826 17/i 440 24 610 795 361 965 438 ----------------------- A -------------------------- -- ---------------------------- H --------------- --- ....... ---------- P C300113F113, C300NBFG SIZE DIMENSIONS - ______________________ WEIGHT in A in. mm C in. mm 0 in. mm G in. mm H in. mm I in. mm J in. mm P in. mm C300BFG lbs. kgs C300NBFG lbs. kgs. 21h 273/4 705 8 203 31/2 89 297/8 759 211/2 546 1415As 379 813A 223 13 330 70 32 78 35 3 281/4 718 8/ia 211 3A6 94 3011A6 779 221/4 565 15/is 392 9/is 233 131/2 343 68 31 81 37 4 29 737 815As 227 3A6 94 3V5A6 811 231/2 597 161/4 412 915/is 252 14 356 75 34 98 44 6 361/2 927 10 254 5 127 433A6 1097 331/4 845 1911/16 500 1 131A6 332 1 141/2 368 1 131 59 171 78 8 423/4 1086 121/4 311 61/2 165 511A6 1297 401/8 1019 1 235Aa 592 15A6 399 1 183As 462 1 275 125 1 351 159 Noryl® is a registered trademark of SABIC Innovative PlastiGSTM. Approvals Approved by the Foundation for Cross-Connection Control and Hydraulic Research at The Unversity of Southern California (FCCCHR-USC) AWAC510-97 For additional approval information please contact the factory or visit our website at www.amesfirewater.com S CUS ® c®us<s> Approved 1048 B64.5 (BFG & OSY Only) Capacity UL/FM Certified Flow Characteristics Flow characteristics collected using butterfly shutoff valves. Flow capacity chart identifies valve performance based upon rated water velocity up to 25fps Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. Rated Flow identifies maximum continuous duty performance determined by AVWJA. UL Flow Rate is 150% of Rated Flow and is not recommended for continuous duty. A\MNA Manual M22 [Appendix Cl recommends that the maximum water velocity in services be not more than lofps. 2½" PSI Service flow Rated Flow *UL Rated Flow 14 = = = N I11 110 o 50 100 150 200 250 300 350 gpm 0 190 380 570 760 950 1140 1330 1pm 7.5 15 fps 6" SI Service Flaw Rated Flow *UL Rated Flow 12 ____ ____ ___ -- N 10 ______ ______ ____ - H ___- _ __ _------ 6 4 0 0 300 600 900 1200 1500 gpm 0 1140 2280 3420 4560 5700 1pm 7.5 12 fps 3,, PSI Service Flow Rated Flow *UL Rated Flow 12 __ __ __ H 02 0 100 200 300 400 500 gpm 0 380 760 1140 1520 1900 1pm 7.5 15 fps 8" SI Service Flow Rated Flow *UL Rated Flow 12 N :EI.. 10 0 500 1000 1500 2000 2500 gpm 0 1900 3800 5700 7600 9500 1pm 7.5 10 fps a-i q 4,' PSI Service Flaw Rated Flow *UL Rated Flow 24 -1 L o N 16 20 12 H 0 100 200 300 400 500 600 700 800 gpm 0 380 760 1140 1520 1900 2280 2660 3040 1pm 7.5 13 fps Jo,, Service Flow Rated Flow *UL Rated Flew 0 500 1000 1500 2000 2500 3000 3500 gpm 0 1900 3800 5700 7600 9500 11400 13300 1pm 7.5 10 fps —1t,1Ifgi Inquire with governing authorities for local installation requirements &0 12 cc Z 00 10 6 F1 _T. T I Approvals Capacity Approved by the Foundation for Cross-Connection Control UL/FM Certified Flow Characteristics and Hydraulic Research at The Unversity of Southern Flow characteristics collected using butterfly shutoff valves. California (FCCCHR-USC) AWVVA C510-97 Flow capacity chart identifies valve performance based For additional approval information please contact the factory or upon rated water velocity up to 25fps visit our website at www.amesfirewater.com • Service Flow is typically determined by a rated velocity of 7.5fps based upon schedule 40 pipe. Rated Flow identifies maximum continuous duty performance determined by AVWVA. C®US recommended for continuous duty. UL Flow Rate is 150% of Rated Flow and is not c us 1048 B64.5 (BFG & OSY Only) • A\MNA Manual M22 [Appendix C] recommends that the maximum water velocity in services be not more than lofps. Horizontal _______Vertical -------N - Pattern 21/211 PSI Service Flow Rated Flow lii Rated Flow PSI 16 14 16 N Z . 14 10 H 12 u's 10 10 6- 0 50 100 150 200 250 300 350 gpm 0 0 190 380 570 760 950 1140 1330 1pm 0 7.5 15 fps 6" Service Flow Rated Flow *UL Rated Flow N Z H 300 600 900 1200 1500 gpm 1140 2280 3420 4560 5700 1pm 7.5 12 fps 3" psi 16 Z 14 N 12 21 10 sa 6 8" Service Flow Rated Flow *UL Rated Flow N Z H 0 100 200 0 380 760 7.5 300 400 500 gpm 0 1140 1520 1900 1pm 0 15 fps 500 1000 1500 2000 2500 gpm 1900 3800 5700 7600 9500 1pm 7.5 10 fps lb - - - - N 7 14---------.--------------- Z H 0 100 200 300 400 500 600 700 800 gpm 0 500 1000 1500 2000 2500 3000 3500 gpm 0 380 760 1140 1520 1900 2280 2660 3040 1pm 0 1900 3800 5700 7600 9500 11400 13300 1pm 7.5 13 fps 7.5 10 fps ATtUtf1 Inquire with governing authorities for local installation requirements psi 4" psi 10" Service Flow Rated Flow *UL Rated flow Service Flow Rated Flow *UL Rated Flow 16 14 PERSHEETFP-1 I Double Check Detector Assem*~ Application Designed for installation on water lines in fire protection systems to protect against both backsiphonage and backpressure of pol- luted water into the potable water supply. Assembly shall provide protection where a potential health hazard does not exist. Standards Compliance (Unless otherwise noted, applies to sizes 4" thru 10') ASSE® Listed 1048 CSA® Certified (4' & 6) AWWA Compliant C 510, and C550 UL® Classified C-UL® Classified FM® Approved NYC MEA 26-00-M VOL 3 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California Meets the requirements of NSF/ANSI 61 * °(025% MAX. WEIGHTED AVERAGE LEAD CONTENT) Materials Main valve body Ductile Iron ASTM A 536 Grade 4 Access covers Ductile Iron ASTM A 536 Grade 4 Coatings FDA Approved fusion epoxy finish Fasteners Stainless Steel, 300 Series Elastomers EPDM (FDA approved) Buna Nitrile (FDA approved) Polymers NORYLTM Springs Stainless Steel, 300 series Features Sizes: 4', 6' , 8', 10" Maximum working water pressure 175 PSI Maximum working water temperature 140°F Hydrostatic test pressure 350 PSI End connections (Grooved for steel) AWWA C606 (Flanged) ANSI B16.1 Class 125 Dimensions & Weights (do not include pkg.) WEIGHT ______ MODEL LESS OS&Y OS&Y WITH WITH SHUTOFF GATE GATE BFLY BFLY SIZE VALVES (GXF) (GXG) (GXF) (GXG) in. I mm lbs. I kg lbs. I kg lbs. kg lbs. I kg lbs. I kg 4 100 105 45 295 134 271 123 175 79 153 69 6 150 174 79 474 215 452 205 278 126 248 112 8 200 402 182 878 398 824 374 592 269 546 248 10 250 420 191 1076 4881 1018 462 694 315 636 288 Options (Suffixes can be combined) LI - with OS & Y gate valves (standard) [I L - less shut-off valves (grooved body connections) LI LM - less water meter - with gpm meter (standard) LI - with cu ft/min meter LI G - with groove end gate valves LI FG - with flanged inlet gate connection and grooved outlet gate connection LI FSC - with epoxy coated wye type strainer (flanged only) LI BG - withgrooved end butterfly valves with integral supervisory switches LI BF - with flanged end butterfly valves with integral supervisory switches LI P1 - with Post Indicator Gate Valve LI —509 - with AWWA C509 gate valves Accessories LI Repair kit (rubber only) LI Thermal expansion tank (Model XT) LI Valve setter (Model FLS or MJS or MJFS) LI Gate valve tamper switch (OSY-40) LI Flange by groove adapter (FLA) LI QT-SET Quick Test Fitting Set 0 LEAD FREE 6&. NSF/ANSI 61 DIMENSIONS (apnrximate) _____________ MODEL B B B C C C 4A SE A WITH GATE WITH BFLY LESS GATE OS&Y OS&Y WITH BFLY D VALVES VALVES VALVES OPEN CLOSED VALVES in. I mm in. mm in. mm in. mm in. mm in. I mm in. I mm in. I mm in. I mm 4 100 185/16 465 30 762 273/4 705 21 533 223/4 578 181/4 460 9 229 8 203 6 150 1811/16 475 351/2 902 32 1/8 816 25 635 301/8 765 233/4 603 101/4 260 10 254 8 200 29 737 46 1165 429/16 1081 34 7/16 845 373/4 959 291/4 743 12 305 13 330 10 250 29 737 471/2 1207 471/2 1207 347/16 845 453/4 1162 353/8 899 13 330 13 330 Zurn Industries, LLC I Wilkins Rev. F 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 3/20 In Canada I zurn Industries Limited Document No. BF-450DA Product No. Model 450DA 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 1 of 2 Co a. U0 10 MODEL 450DA 4" & 6" (STANDARD & METRIC) FLOW RATES (Its) 25.2 50.5 75.7 0.0 0 15 Co 0. Co Co 10 100.9 103 a. Co 69 ui 34 Co uJ a DIRECTION OF FLOW Al OUTDOOR INSTALLATION DIMENSIONS approximate) Al SETTER Al SETTER MODEL SIZE END TO END TO END END FLS MJS in. mm in. mm in. MITI 4 i 100 31 5/16 795 29.313 745 6 I 150 343/4 884 32.75 832 8 I 200 47 1194 44.625 1133 10 I 250 1 51 12951 47 1194 Flow Characteristics ORated flow (established by approval agencies) Co U) 69 w 34 Co w 0 4000 0 400 800 1200 1600 FLOW RATES (GPM) MODEL 450DA 8" & 10" (STANDARD & METRIC) FLOW RATES (Its) 0.0 63.1 126.2 189.3 252.4 &15 103 a 200mm 10" (250mm) CL 0 1000 2000 3000 FLOW RATES (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's in- structions and the latest edition of the Uniform Plumb- ing Code. Unless otherwise specified, the assembly shall be mounted above adequate drains with sufficient side clearance for testing and maintenance. The instal- lation shall be made so that no part of the unit can be submerged. r------------- PROTECVE I ENCLOSURE WILKINS VALVE SETTER MJFS Capacity thru Schedule 40 Pipe (GPM) Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 2 1/2" 75 112 149 224 115 173 230 346 198 298 397 595 6" 450 675 900 1351 8" 780 1169 1559 2339 10" 1229 1843 2458 3687 Specifications The Double Check Detector Backflow Preventer shall be certified to NSF/ANSI 61, ASSE® Listed 1048 and sup- plied with full port OS & Y gate valves. The main body and access cover shall be epoxy coated ductile iron (ASTM A 536 Grade 4), the seat ring and check valve shall be NORYLTM, the stem shall be stainless steel (ASTM A 276) and the seat disc elastomers shall be EPDM. The checks shall be accessible for maintenance without remov- ing the device from the line. The Double Check Detector Backflow Preventer shall be a ZURN WILKINS Model 450DA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, 877-892-5216 www.zurn.com Page 2 of 2 / POTTER \U ROEMER FIRE PRO Member of Morris Group International- CONNECTIONS (FDC) EXPOSED FIRE DEPT. INLET CONNECTIONS-CLAPPER TYPE Model/Series No. 5710-5734 SERIES SPECIFICATIONS TWO-WAY WITH SINGLE CLAPPER Cast brass two-way inlet body, swing clapper and pin lug swivel. Back or angle outlet as selected by model number. Lettering as selected. Size 4' x 2-1/2" x 2-1/2". TWO-WAY WITH DOUBLE CLAPPER Cast brass two-way inlet body, drop clappers and pin lug swivels. Size and outlet as selected by model number. Lettering as selected. MODEL SELECTION TWO-WAY WITH SINGLE CLAPPER J 5710 Back Outlet (U/L & FM Listed) (A 5715 Angle Outlet (U/L & FM Listed) TWO-WAY WITH DOUBLE CLAPPER IJ 5721 Back Outlet IJ 5722 Back Outlet U 5723 Back Outlet U 5724 Back Outlet U 5731 Angle Outlet U 5732 Angle Outlet U 5733 Angle Outlet U 5734 Angle Outlet Note: Refer to Model Dimensional Chart for U/L & FM Listing PRODUCT OPTIONS FINISHES: -B Polished Brass U -C Rough Chrome Plated Body U -D Polished Chrome Plated THREADS: N.S.T. EOther_ LETTERING AVAILABLE: U AUTO. SPKR. U STANDPIPE Call Potter Roamer - Fire Pro for current listings and POTTER ROEMERIFIRE PRO approvals. Dimensions am subject to manufacturer's tolerance and may change without notice. Potter Roamer. FIRE EQUIPMENT - MANUFACTURERS' IJIVFSA Headquarters: Also in: Fire Pro assumes no responsibility for use of void or ASSOCIATION P.O. Box 3527 New York (800) 526-4592 superceded data. © Copyright Potter Roamer- Fire Pro, city of Industry, CA Chicago (800) 547-3473 Member of Mon-is Group International " Please visit polterroemer.com for most current specifications. [] ' 'AS E 91744 U.S.A. Atlanta (800) 762-0542 Los Angeles Area Miami (866) 961-3473 ri 800-366-3 473 Dallas (866) 644-3473 51105134 SERIES Date: 03/27/14 NFPA ,' 626-855-4890 www.potterroemer.com ,' ,) (Giacomini A140 Fig. No. 4510 4" GROOVED TYPICAL INSTALLATION Fig. No. 4515 4" Male x Grooved I POTIERROEMER J1.4.A JeER Cerritos California :PR07ECTM EOUIPMEJIfl/ Fire Protection Products V SWING CHECK VALVE SWING CHECK VALVE REGULARLY FURNISHED: 4" Forged body with spring loaded brass check, body tap- ped 1/2" N.P.T. at inlet for ball drip. FUNCTION: Used to permit Bow only in designated direction and prevent backflow. Type of installation as selected by figure number. Type of Installation Fig. No. Size Inlet Outlet 4510 4" Grooved Grooved 4515 4 M-N.P.T. Grooved jJ 4520 4' M-N.P.T. F-N.P.T. I Fig. No. 4520 4" Male x Female I VAlt I I FIGURE NUMBER 9-93 1