Loading...
HomeMy WebLinkAbout3130 MADISON ST; ; FPR2019-0166; PermitPERMIT REPORT (rccity of Carlsbad Print Date: 07/06/2022 Permit No: FPR2019-0166 Job Address: 3130 MADISON ST, CARLSBAD, CA 92008-3001 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Multifamily Fire Sprinkler Parcel #: 2040310400 Track #: Applied: 08/14/2019 Valuation: $0.00 Lot #: Issued: 11/06/2019 Occupancy Group: Project #: Finaled Close Out: 07/06/2022 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check U: Project Title: Description: MADISON APTS -NEW SPRINKLER SYSTEM (142 HEADS) FOR 4 UNIT APT PROJECT (NEW CONSTRUCTION, 3 STORIES) FPContractor: RIOS FIRE PROTECTION-INACTIVE P0 BOX 1546 EL CAJON, CA 92022-0000 (619) 212-0956 FEE AMOUNT FIRE NFPA 13 System > 100 heads (includes 1 riser) $858.00 Total Fees: $858.00 Total Payments To Date: $858.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov No. 180 0 r19ot47(6' CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A. TO BE COMPLETED BY CUSTOMER PROJECT NAME: Madison Apartments SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 3130 Madison St CITY: Carlsbad PHONE: ( 619 ) 212-0956 (Rios Fire Protection) FAX NUMBER: Largest Building (ft.2): 13,979 Sprinkled? YES Construction Type: V-B SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Madison St at Oak Ave TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 82 PSI Hydrant Number (if applicable): H61142 Elevation of test: 52 Feet Main Size: 12 INCH Pressure Zone: 241 Feet Date/Time of Test: Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 5,225 GPM Residual Pressure 39 PSI At peak demand, this water system is capable of providing a fire flow discharge at 20 psi of 6,650 gpm. However, this flow exceeds the District's maximum pipeline velocity of 10 fps. The maximum fire flow that meets both the velocity and pressure criteria is 5,225 gpm. There was no specific requestforfire flow from the Client or Fire Department. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: Name: Jennifer _R_Mael_P.E. Eng. Lic. No. (if applicable): C69606 Signature _____________________________________ Date: 03/21/2019 S W.'a(I 61 m. 711krel Tamp, =k b June 18, 2019 HYDRAULIC CALCULATIONS FOR MADISON APARTMANETS FILE NUMBER: MA-01-015.SDF -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@BOR): SPRINKLER ORIFICE SIZE: ORDINARY HAZARD, GI .15 gpm/ 1538 sq.ft. GARAGE LEVEL 130 sq.ft. 15 SPRINKLERS 347.5 gpm 597.5 gpm 347.5 gpm @ 32.7 psi 1/2" inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION DESIGN! LAYOUT: ROBERTO RIOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-1025305 WATER DEPARTMENT: CARLSBAD FIRE DEPARTMENT CONTACT: JENIFER MAEL WATER PRESSURE INFORMATION: 82.0 psi STATIC 39.0 psi RESD CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. P.O. Box 1546, El Cajon, CA 92022/619-212-0956 Lic. C16/1025305 www.riosfireprotection.com SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 6/18/2019AM FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-1ST FL.SDF JOB TITLE: MADISON AVENUE RA1 (.15 gpm/1500 sq.ft.) WATER SUPPLY DATA SOURCE STATIC RESID. PLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 73.8 35.1 5225.0 73.1 597.5 45.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 597.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 347.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (PT) (PSI) (GPM) 101 10.0 K= 5.60 12.1 19.5 102 10.0 K= 5.60 12.6 19.9 103 10.0 - - - - 14.0 - - - 103A 10.0 K= 5.60 12.9 20.1 104 10.0 K= 5.60 16.4 22.7 105 10.0 K= 5.60 19.9 25.0 106 10.0 K= 5.60 20.0 25.0 107 10.0 K= 5.60 15.3 21.9 108 10.0 K= 5.60 15.9 22.3 109 10.0 K= 5.60 18.1 23.8 110 10.0 K= 5.60 20.4 25.3 111 10.0 K= 5.60 15.8 22.3 112 10.0 K= 5.60 16.4 22.7 113 10.0 K= 5.60 18.7 24.2 114 10.0 K= 5.60 21.5 25.9 115 10.0 K= 5.60 22.9 26.8 Ml 10.0 - - - - 21.1 - - - M1A 10.0 - - - - 21.2 - - - M2 10.0 - - - - 21.3 - - - M3 10.0 - - - - 21.4 - - - M4 10.0 - - - 21.7 - - - M5 10.0 - - - - 22.1 - - - M6 10.0 - - - - 22.8 - - - M7 10.0 - - - - 23.5 - - - M8 10.0 - - - - 26.1 - - - TOR 9.0 - - - - 28.7 BOR 1.0 - - - - 32.7 DIP -3.0 - - - - 35.0 - - - DA 3.0 - - - - 32.7 DC 3.0 - - - - 40.7 - - - SRC -3.0 SOURCE 45.0 347.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/18/2019AM PILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-1ST P L . S D F JOB TITLE: MADISON AVENUE RA1 (.15 gpm/1500 sq.ft.) PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -19.5 1.442 PL 10.00 PF 0.5 101 10.0 5.6 12.1 19.5 3.8 120 FTG T PE 0.0 102 10.0 5.6 12.6 19.9 0.026 TL 18.00 PV Pipe: 2 -39.4 1.442 PL 6.50 PF 1.4 102 10.0 5.6 12.6 19.9 7.7 120 FTG T PE 0.0 103 10.0 0.0 14.0 0.0 0.097 TL 14.50 PV Pipe: 3 -20.1 1.049 PL 6.75 PP 1.1 103A 10.0 5.6 12.9 20.1 7.5 120 FTG E PH 0.0 103 10.0 0.0 14.0 0.0 0.131 TL 8.75 PV Pipe: 4 -59.5 1.442 PL 3.75 PP 2.4 103 10.0 0.0 14.0 0.0 11.7 120 FTG T PE 0.0 104 10.0 5.6 16.4 22.7 0.207 TL 11.75 PV Pipe: 5 -82.2 1.442 PL 4.50 PP 4.7 104 10.0 5.6 16.4 22.7 16.1 120 FTG T PH 0.0 MIA 10.0 0.0 21.2 0.0 0.377 TL 12.50 PV Pipe: 6 -25.0 1.049 PL 4.50 PP 1.3 105 10.0 5.6 19.9 25.0 9.3 120 FTG E PE 0.0 Ml 10.0 0.0 21.1 0.0 0.196 TL 6.50 PV Pipe: 7 -25.0 1.049 PL 4.50 PP 1.3 106 10.0 5.6 20.0 25.0 9.3 120 FTG E PE 0.0 M2 10.0 0.0 21.3 0.0 0.197 TL 6.50 PV Pipe: 8 -21.9 1.442 PL 10.00 PP 0.6 107 10.0 5.6 15.3 21.9 4.3 120 FTG T PE 0.0 108 10.0 5.6 15.9 22.3 0.033 TL 18.00 PV Pipe: 9 -44.3 1.442 PL 10.00 PP 2.2 108 10.0 5.6 15.9 22.3 8.7 120 FTG T PE 0.0 109 10.0 5.6 18.1 23.8 0.120 TL 18.00 PV Pipe: 10 -68.1 1.442 PL 4.50 PP 3.3 109 10.0 5.6 18.1 23.8 13.4 120 FTG T PH 0.0 M3 10.0 0.0 21.4 0.0 0.266 TL 12.50 PV Pipe: 11 -25.3 1.049 PL 4.50 PP 1.3 110 10.0 5.6 20.4 25.3 9.4 120 FTG H PE 0.0 M4 10.0 0.0 21.7 0.0 0.201 TL 6.50 PV Pipe: 12 -22.3 1.442 PL 10.00 PP 0.6 111 10.0 5.6 15.8 22.3 4.4 120 FTG T PE 0.0 112 10.0 5.6 16.4 22.7 0.034 TL 18.00 PV Pipe: 13 -45.0 1.442 PL 10.00 PP 2.2 112 10.0 5.6 16.4 22.7 8.8 120 FTG T PE 0.0 113 10.0 5.6 18.7 24.2 0.124 TL 18.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/18/2019A14 FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-1ST PL.SDF JOB TITLE: MADISON AVENUE RA1 (.15 gpm/1500 sq.ft.) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(PPS) HW(C) (PT) SUM. NODES (PT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -69.2 1.442 FL 4.50 PP 3.4 113 10.0 5.6 18.7 24.2 13.6 120 FTG T PP 0.0 M5 10.0 0.0 22.1 0.0 0.275 TL 12.50 PV Pipe: 15 -25.9 1.049 PL 4.50 PP 1.4 114 10.0 5.6 21.5 25.9 9.6 120 FTG E PE 0.0 M6 10.0 0.0 22.8 0.0 0.211 TL 6.50 PV Pipe: 16 -26.8 1.442 FL 4.50 PP 0.6 115 10.0 5.6 22.9 26.8 5.3 120 FTG T FE 0.0 M7 10.0 0.0 23.5 0.0 0.048 TL 12.50 PV Pipe: 17 -25.0 4.260 PL 2.00 PP 0.0 Ml 10.0 0.0 21.1 0.0 0.6 120 FTG T FE 0.0 M1A 10.0 0.0 21.2 0.0 0.000 TL 28.00 PV Pipe: 18 -107.1 4.260 PL 7.50 PP 0.1 M1A 10.0 0.0 21.2 0.0 2.4 120 FTG T PP 0.0 N2 10.0 0.0 21.3 0.0 0.003 TL 33.50 PV Pipe: 19 -132.2 4.260 FL 4.00 PP 0.1 M2 10.0 0.0 21.3 0.0 3.0 120 FTG T FE 0.0 M3 10.0 0.0 21.4 0.0 0.005 TL 30.00 PV Pipe: 20 -200.2 4.260 FL 8.00 PP 0.3 M3 10.0 0.0 21.4 0.0 4.5 120 FTG T PP 0.0 M4 10.0 0.0 21.7 0.0 0.010 TL 34.00 PV Pipe: 21 -225.5 4.260 FL 3.50 PP 0.4 M4 10.0 0.0 21.7 0.0 5.1 120 FTG T FE 0.0 M5 10.0 0.0 22.1 0.0 0.012 TL 29.50 PV Pipe: 22 -294.7 4.260 FL 9.50 PP 0.7 M5 10.0 0.0 22.1 0.0 6.6 120 FTC T PP 0.0 M6 10.0 0.0 22.8 0.0 0.020 TL 35.50 PV Pipe: 23 -320.7 4.260 FL 2.50 PP 0.7 M6 10.0 0.0 22.8 0.0 7.2 120 FTG T PP 0.0 M7 10.0 0.0 23.5 0.0 0.024 TL 28.50 PV Pipe: 24 -347.5 4.260 PL 42.00 PP 2.6 M7 10.0 0.0 23.5 0.0 7.8 120 FTG 2ET PE 0.0 MB 10.0 0.0 26.1 0.0 0.028 TL 94.00 PV Pipe: 25 -347.5 4.260 PL 49.00 PP 2.1 MB 10.0 0.0 26.1 0.0 7.8 120 FTG T PE 0.4 TOR 9.0 0.0 28.7 0.0 0.028 TL 75.00 PV Pipe: 26 -347.5 4.260 PL 9.00 PP 0.6 TOR 9.0 0.0 28.7 0.0 7.8 120 FTG E FE 3.5 BOR 1.0 0.0 32.7 0.0 0.028 TL 22.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/18/2019AM FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-1ST FL.SDF JOB TITLE: MADISON AVENUE RA1 (.15 gpm/1500 sq.ft.) PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 27 -347.5 4.220 PL 6.00 PF 0.5 BOR 1.0 0.0 32.7 0.0 8.0 120 FTG S PE 1.7 DIP -3.0 0.0 35.0 0.0 0.029 TL 18.58 PV Pipe: 28 -347.5 4.230 PL 10.00 PF 0.3 DIP -3.0 0.0 35.0 0.0 7.9 120 FTG ---- PE -2.6 DA 3.0 0.0 32.7 0.0 0.029 TL 10.00 LW Pipe: 29 FIXED PRESSURE LOSS DEVICE DC 3.0 0.0 40.7 0.0 8.0 psi, 347.5 gpm DA 3.0 0.0 32.7 0.0 Pipe: 30 -347.5 4.230 PL 30.00 PF 1.7 DC 3.0 0.0 40.7 0.0 7.9 120 FTG TG PE 2.6 SRC -3.0 SRCE 45.0 (N/A) 0.029 TL 57.99 PV NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.102 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 16.1 ft/sec at pipe 5. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SRC under full flow conditions is 72.78 psi with a flow of 732.62 gpm. PIPE FITTINGS TABLE HASS Pipe Table Name: standard.pip SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/18/2019AM FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-1ST FL.SDF JOB TITLE: MADISON AVENUE RA1 (.15 gpm/1500 sq.ft.) PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEli ChkVlv BfyViv GatVlv AlmChk DPVlv NPTee 4.220 12.58 25.15 7.55 27.67 15.09 2.52 25.15 25.15 25.15 4.230 12.72 25.44 7.63 27.99 15.27 2.54 25.44 25.44 25.44 PAGE: A MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEl1 ChkVlv BfyViv GatVlv AlmChk DPViv Tee 1.049 2.00 5.00 2.00 5.00 6.00 1.00 10.00 2.00 5.00 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngE1l ChkVlv BfyVlv GatVlv AlmChk DPViv NPTee 1.442 4.00 8.00 3.00 9.00 8.00 1.00 12.00 12.00 8.00 4.260 13.00 26.00 8.00 29.00 16.00 3.00 26.00 26.00 26.00 :ss C 1A- 70.0 60.0 G A U 50.0 G B 2A 40.0 P R 30.0 E S S 20.0 U R 10.0 E SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/18/2019AM FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-1ST FL.SDF JOB TITLE: MADISON AVENUE RAl (.15 gpm/1500 sq.ft.) WATER SUPPLY ANALYSIS Static: 73.80 psi Resid: 35.10 psi Flow: 5225.0 gpm LEGEND Available pressure 73.10 psi 8 597.5 gpm Required pressure 44.96 psi @ 597.5 gpm Avail. OnSite Demand Press. 73.10 psi @ 347.5 gpm Req. OnSite Demand Press. 44.96 psi @ 347.5 gpm Source Supply Curve System Demand Curve Available at Source 12018002400 3000 3600 4200 4800 5400 6000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 6/18/2019AM FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-1ST FL.SDF JOB TITLE: MADISON AVENUE RA1 (.15 gpm/1500 sq.ft.) WATER SUPPLY CURVE 84+ 77+ *0 70+ \\ I \ I \ I \\ 63+ I \\ P56+ R I \\ E I \ S I \\ S 49+ \ U I \ R IX \\ E \ 42+ \ \\ P S I I 35+ * <-35.1 psi 8 5225 gpm I Flow Test Point 28+ 21+ 14+ LEGEND I, I X = Required Water Supply IT 44.96 psi 8 597.5 gpm IF 7+ IF 0 = Available Water Supply IF I 73.10 psi @ 597.5 gpm it 0++-+---+----+-----+------+--------+--------+---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) June 18, 2019 HYDRAULIC CALCULATIONS FOR MADISON APARTMENTS FILE NUMBER: MA-0] -015.SDF -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS: TOTAL SPRINKLER WATER FLOW REQUIRED: TOTAL WATER REQUIRED (including hose): FLOW AND PRESSURE (@BOR): SPRINKLER ORIFICE SIZE: LIGHT HAZARD .10 gpm/ 4 HEADS ADJACENT THIRD FLOOR 200 sq.ft. 4 SPRINKLERS 85.6 gpm 185.6 gpm 85.6 gpm @ 60.1 psi 7/16" inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION DESIGN! LAYOUT: ROBERTO RTOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-1025305 WATER DEPARTMENT: CARLSBAD FIRE DEPARTMENT CONTACT: JENIFER MAEL WATER PRESSURE INFORMATION: 82.0 psi STATIC 39.0 psi RESD CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. P.O. Box 1546, El Cajon, CA 92022/619-212-0956 Lic. C16/1025305 www.riosfireprotection.com SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 73.8 35.1 5225.0 73.7 185.6 68.0 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 185.6 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 85.6 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 301 30.5 K= 4.90 16.9 20.1 302 30.5 K= 4.90 16.7 20.0 303 30.5 K= 4.90 18.3 21.0 304 30.5 K= 4.90 24.9 24.5 305 30.5 - - - - 30.6 306 30.5 - - - - 30.6 - - - 307 30.5 - - - - 30.6 - - - Ri 31.0 - - - - 17.3 - - - R2 31.0 - - - - 19.0 - - - R3 31.0 - - - - 25.3 - - - R4 31.0 - - - - 30.4 - - - R5 31.0 - - - - 30.4 - - - R6 31.0 - - - - 35.3 - - - R7 31.0 - - - - 40.2 - - - R8 31.0 - - - - 39.2 - - - R9 10.0 - - - - 51.8 - - - RiO 10.0 - - - - 51.0 - - - M1A 10.0 - - - - 55.9 M8 10.0 - - - - 55.9 - - - TOR 10.0 - - - - 56.1 BOR 1.0 - - - - 60.1 - - - DIP -3.0 - - - - 61.9 - - - DA 3.0 - - - - 59.3 DC. 3.0 - - - - 65.3 SRC -3.0 SOURCE 68.0 85.6 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUH01-015-3rd FLOOR PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -20.1 1.101 PL 2.50 PF 0.7 301 30.5 4.9 16.9 20.1 6.8 150 FTG H PE -0.2 Ri 31.0 0.0 17.3 0.0 0.069 TL 9.50 PV Pipe: 2 -20.0 1.101 PL 5.50 PF 0.9 302 30.5 4.9 16.7 20.0 6.7 150 FTG E PE -0.2 Ri 31.0 0.0 17.3 0.0 0.068 TL 12.50 PV Pipe: 3 -21.0 1.101 PL 5.60 PF 0.9 303 30.5 4.9 18.3 21.0 7.1 150 FTG E PH -0.2 R2 31.0 0.0 19.0 0.0 0.074 TL 12.60 PV Pipe: 4 -24.5 1.101 PL 1.00 PF 0.6 304 30.5 4.9 24.9 24.5 8.2 150 FTG T PE -0.2 R3 31.0 0.0 25.3 0.0 0.099 TL 6.00 PV Pipe: 5 0.0 1.101 PL 9.50 PP 0.0 305 30.5 0.0 30.6 0.0 0.0 150 FTG E PE -0.2 R4 31.0 0.0 30.4 0.0 0.000 TL 16.50 PV Pipe: 6 0.0 1.101 PL 0.50 PF 0.0 306 30.5 0.0 30.6 0.0 0.0 150 FTG ---- PH -0.2 R4 31.0 0.0 30.4 0.0 0.000 TL 0.50 PV Pipe: 7 0.0 1.101 PL 11.50 PP 0.0 307 30.5 0.0 30.6 0.0 0.0 150 FTG 2E PH -0.2 R5 31.0 0.0 30.4 0.0 0.000 TL 25.50 PV Pipe: 8 -40.1 1.101 PL 2.00 PP 1.7 Ri 31.0 0.0 17.3 0.0 13.5 150 FTG T PH 0.0 R2 31.0 0.0 19.0 0.0 0.247 TL 7.00 PV Pipe: 9 -61.1 1.101 PL 6.75 PP 6.3 R2 31.0 0.0 19.0 0.0 20.6 150 FTG T PE 0.0 R3 31.0 0.0 25.3 0.0 0.537 TL 11.75 PV Pipe: 10 -85.6 1.394 PL 10.00 PP 5.1 R3 31.0 0.0 25.3 0.0 18.0 150 FTG T PE 0.0 R5 31.0 0.0 30.4 0.0 0.317 TL 16.00 PV Pipe: 11 0.0 1.394 PL 2.00 PP 0.0 R4 31.0 0.0 30.4 0.0 0.0 150 FTG T PH 0.0 R5 31.0 0.0 30.4 0.0 0.000 TL 8.00 PV Pipe: 12 -85.6 1.394 PL 9.50 PF 4.9 R5 31.0 0.0 30.4 0.0 18.0 150 FTG T PH 0.0 R6 31.0 0.0 35.3 0.0 0.317 TL 15.50 PV Pipe: 13 -41.7 1.394 PL 46.00 PP 4.9 R6 31.0 0.0 35.3 0.0 8.8 150 FTG 2T PH 0.0 R7 31.0 0.0 40.2 0.0 0.084 TL 58.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015--3rd FLOOR PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -43.8 1.394 PL 28.00 PF 3.9 R6 31.0 0.0 35.3 0.0 9.2 150 FTG ET PE 0.0 R8 31.0 0.0 39.2 0.0 0.092 TL 42.00 PV Pipe: 15 -41.7 1.394 PL 22.00 PF 2.5 R7 31.0 0.0 40.2 0.0 8.8 150 FTG S PE 9.1 R9 10.0 0.0 51.8 0.0 0.084 TL 30.00 PV Pipe: 16 -43.8 1.394 PL 22.00 PF 2.8 R8 31.0 0.0 39.2 0.0 9.2 150 FTC S PE 9.1 RiO 10.0 0.0 51.0 0.0 0.092 TL 30.00 PV Pipe: 16A -41.7 1.442 PL 28.50 PF 4.0 R9 10.0 0.0 51.8 0.0 8.2 120 FTG ST PE 0.0 M1A 10.0 0.0 55.9 0.0 0.108 TL 37.50 PV Pipe: 16B -43.8 1.442 PL 35.50 PF 4.9 RiO 10.0 0.0 51.0 0.0 8.6 120 FTG 25 FE 0.0 MB 10.0 0.0 55.9 0.0 0.118 TL 41.50 PV Pipe: 16C -41.7 4.000 PL 76.00 FT 0.1 M1A 10.0 0.0 55.9 0.0 1.1 120 FTG 25T FE 0.0 MB 10.0 0.0 55.9 0.0 0.001 TL 116.00 PV Pipe: 17 -85.6 4.000 FL 49.00 PF 0.2 MB 10.0 0.0 55.9 0.0 2.2 120 FTC T PS 0.0 TOR 10.0 0.0 56.1 0.0 0.003 TL 69.00 PV Pipe: 18 -85.6 4.000 PL 9.00 PF 0.1 TOR 10.0 0.0 56.1 0.0 2.2 120 FTG S PS 3.9 BOR 1.0 0.0 60.1 0.0 0.003 TL 19.00 PV Pipe: 19 -85.6 4.220 FL 6.00 PF 0.0 BOR 1.0 0.0 60.1 0.0 2.0 140 FTG E PS 1.7 DIP -3.0 0.0 61.9 0.0 0.002 TL 22.73 PV Pipe: 20 -85.6 4.230 PL 10.00 PP 0.0 DIP -3.0 0.0 61.9 0.0 2.0 150 FTC ---- PE -2.6 DA 3.0 0.0 59.3 0.0 0.001 TL 10.00 PV Pipe: 21 FIXED PRESSURE LOSS DEVICE DC 3.0 0.0 65.3 0.0 6.0 psi, 85.6 gpm DA 3.0 0.0 59.3 0.0 Pipe: 22 -85.6 4.230 PL 30.00 PP 0.1 DC 3.0 0.0 65.3 0.0 2.0 150 FTG TG PE 2.6 SRC -3.0 SRCE 68.0 (N/A) 0.001 TL 72.29 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.004 gpm and a maximum imbalance at any node of 0.090 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 20.6 ft/sec at pipe 9. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SRC under full flow conditions is 73.72 psi with a flow of 190.82 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEli ChkVlv BfyViv GatViv AimChk DPVlv NPTee 4.220 12.58 25.15 7.55 27.67 15.09 2.52 25.15 25.15 25.15 4.230 12.72 25.44 7.63 27.99 15.27 2.54 25.44 25.44 25.44 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent' Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.442 3.00 6.00 2.00 7.00 6.00 1.00 0.00 0.00 4.000 10.00 20.00 6.00 22.00 12.00 2.00 0.00 0.00 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 1.394 8.00 6.00 1.00 0.00 1.00 2.00 0.00 2.00 P R 30.0 E S 20.0 U R 10.0 E N". <"S \" SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015--3rd FLOOR WATER SUPPLY ANALYSIS Static: 73.80 psi Resid: 35.10 psi Flow: 5225.0 gpm 1A' 70.0 2A 60.0 G A U 50.0 G S 40.0 LEGEND - Available pressure 73.72 psi @ 185.6 gpm Required pressure 67.97 psi @ 185.6 gpm Avail. OnSite Demand Press. 73.72 psi @ 85.6 gpm kj Req. OnSite Demand Press. 67.97 psi 8 85.6 gpm Source Supply Curve System Demand Curve Available at Source 0.0 p 5 i -14.7 12018002400 3000 3600 4200 4800 5400 6000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/18/2019F1LE5\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR WATER SUPPLY CURVE 84+ 77+ 70+ \\ x \ I \ I \\ 63+ \ \ I \\ \ P 56+ \ R I \\ S \ S I \\ 5 49+ \ U I \ R I E 42+ \ I \\ P1 S I I 35+ * <-35.1 psi 8 5225 gpm Flow Test Point 28+ 21+ 14+ LEGEND IT I I, I X = Required Water Supply IF I 67.97 psi @ 185.6 gpm 7+ 0 = Available Water Supply 73.72 psi 8 185.6 gpm I, 0++-+---+----+-----+------+--------+--------+---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) riit1o1UtI)Ic(sitl June 18, 2019 HYDRAULIC CALCULATIONS FOR MADISON APARTMENTS FILE NUMBER: MA-0 1 -0 15. SDF -DESIGN DATA- OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS: IPIIIV114] 10 gpm/ 4 HEADS COMP. THIRD FLOOR 200 sq.ft. 4 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 81.2 gpm TOTAL WATER REQUIRED (including hose): 181.2 gpm FLOW AND PRESSURE (@BOR): 81.2 gpm @ 46.4 psi SPRINKLER ORIFICE SIZE: 7/16" inch NAME OF CONTRACTOR: RIOS FIRE PROTECTION DESIGN! LAYOUT: ROBERTO RIOS AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-102530S WATER DEPARTMENT: CARLSBAD FIRE DEPARTMENT CONTACT: JENIFER MAEL WATER PRESSURE INFORMATION: 82.0 psi STATIC 39.0 psi RESD CALCULATIONS BY HASS COMPUTER PROGRAM HRS SYSTEMS, INC. P.O. Box 1546, El Cajon, CA 92022/619-212-0956 Lic. C16/1025305 www.riosfireprotection.com SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SRC 73.8 35.1 5225.0 73.7 181.2 54.2 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 181.2 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 81.2 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 301 30.5 - - - - 18.1 - - - 302 30.5 - - - - 18.1 - - - 303 30.5 - - - - 18.1 - - - 304 30.5 K= 4.90 17.6 20.6 305 30.5 K= 4.90 16.7 20.0 306 30.5 K= 4.90 17.7 20.6 307 30.5 K= 4.90 16.7 20.0 Ri 31.0 - - - - 17.8 - - - R2 31.0 - - - - 17.8 - - - R3 31.0 - - - - 17.8 - - - R4 31.0 - - - - 17.6 - - - R5 31.0 - - - - 18.2 - - - R6 31.0 - - - - 22.7 - - - R7 31.0 - - - - 27.1 - - - R8 31.0 - - - - 26.2 - - - R9 10.0 - - - - 38.5 - - - RiO 10.0 - - - - 37.8 - - - M1A 10.0 - - - - 42.2 - - - M8 10.0 - - - - 42.2 - - - TOR 10.0 - - - - 42.4 - - - BOR 1.0 - - - - 46.4 - - - DIP -3.0 - - - - 48.1 - - - DA 3.0 - - - - 45.5 DC 3.0 - - - - 51.5 - - - SRC -3.0 SOURCE 54.2 81.2 - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/18/2019FILES\HRS SYSTRMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (PT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 0.0 1.101 PL 2.50 PP 0.0 301 30.5 0.0 18.1 0.0 0.0 150 FTG R PR -0.2 Ri 31.0 0.0 17.8 0.0 0.000 TL 9.50 PV Pipe: 2 0.0 1.101 PL 5.50 PP 0.0 302 30.5 0.0 18.1 0.0 0.0 150 FTG F PR -0.2 Ri 31.0 0.0 17.8 0.0 0.000 TL 12.50 PV Pipe: 3 0.0 1.101 PL 5.60 PP 0.0 303 30.5 0.0 18.1 0.0 0.0 150 FTG E PR -0.2 R2 31.0 0.0 17.8 0.0 0.000 TL 12.60 PV Pipe: 4 -20.6 1.101 PL 1.00 PP 0.4 304 30.5 4.9 17.6 20.6 6.9 150 FTG T FE -0.2 R3 31.0 0.0 17.8 0.0 0.072 TL 6.00 PV Pipe: 5 -20.0 1.101 FL 9.50 PP 1.1 305 30.5 4.9 16.7 20.0 6.7 150 FTG E PR -0.2 R4 31.0 0.0 17.6 0.0 0.068 TL 16.50 PV Pipe: 6 -20.6 1.101 FL 0.50 PP 0.0 306 30.5 4.9 17.7 20.6 7.0 150 FTG ---- PR -0.2 R4 31.0 0.0 17.6 0.0 0.072 TL 0.50 PV Pipe: 7 -20.0 1.101 PL 11.50 PP 1.7 307 30.5 4.9 16.7 20.0 6.7 150 FTG 2E PR -0.2 R5 31.0 0.0 18.2 0.0 0.068 TL 25.50 PV Pipe: 8 0.0 1.101 FL 2.00 PP 0.0 Ri 31.0 0.0 17.8 0.0 0.0 150 FTG T PR 0.0 R2 31.0 0.0 17.8 0.0 0.000 TL 7.00 PV Pipe: 9 0.0 1.101 PL 6.75 PP 0.0 R2 31.0 0.0 17.8 0.0 0.0 150 FTG T PR 0.0 R3 31.0 0.0 17.8 0.0 0.000 TL 11.75 PV Pipe: 10 -20.6 1.394 FL 10.00 PP 0.4 R3 31.0 0.0 17.8 0.0 4.3 150 FTG T PR 0.0 R5 31.0 0.0 18.2 0.0 0.023 TL 16.00 PV Pipe: ii -40.6 1.394 PL 2.00 PP 0.6 R4 31.0 0.0 17.6 0.0 8.5 150 FTG T PR 0.0 R5 31.0 0.0 18.2 0.0 0.080 TL 8.00 PV Pipe: 12 -81.2 1.394 PL 9.50 PP 4.5 R5 31.0 0.0 18.2 0.0 17.1 150 FTG T PR 0.0 R6 31.0 0.0 22.7 0.0 0.288 TL 15.50 PV Pipe: 13 -39.6 1.394 PL 46.00 PP 4.4 R6 31.0 0.0 22.7 0.0 8.3 150 FTG 2T PR 0.0 R7 31.0 0.0 27.1 0.0 0.076 TL 58.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/18/2019F1LES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 14 -41.6 1.394 FL 28.00 PR 3.5 R6 31.0 0.0 22.7 0.0 8.7 150 FTG ET PS 0.0 R8 31.0 0.0 26.2 0.0 0.084 TL 42.00 PV Pipe: 15 -39.6 1.394 PL 22.00 PF 2.3 R7 31.0 0.0 27.1 0.0 8.3 150 FTG E FE 9.1 R9 10.0 0.0 38.5 0.0 0.076 TL 30.00 PV Pipe: 16 -41.6 1.394 PL 22.00 PR 2.5 RB 31.0 0.0 26.2 0.0 8.7 150 FTG E FE 9.1 RiO 10.0 0.0 37.8 0.0 0.084 TL 30.00 PV Pipe: 16A -39.6 1.442 PL 28.50 PF 3.7 R9 10.0 0.0 38.5 0.0 7.8 120 FTG ET PE 0.0 M1A 10.0 0.0 42.2 0.0 0.098 TL 37.50 PV Pipe: 16B -41.6 1.442 FL 35.50 PF 4.4 RiO 10.0 0.0 37.8 0.0 8.2 120 FTG 2E FE 0.0 MB 10.0 0.0 42.2 0.0 0.107 TL 41.50 PV Pipe: 16C -39.6 4.000 FL 76.00 PF 0.1 M1A 10.0 0.0 42.2 0.0 1.0 120 FTG 2ET PR 0.0 MB 10.0 0.0 42.2 0.0 0.001 TL 116.00 PV Pipe: 17 -81.2 4.000 FL 49.00 PF 0.2 MB 10.0 0.0 42.2 0.0 2.1 120 FTG T FE 0.0 TOR 10.0 0.0 42.4 0.0 0.003 TL 69.00 PV Pipe: 18 -81.2 4.000 FL 9.00 PR 0.0 TOR 10.0 0.0 42.4 0.0 2.1 120 FTG E PR 3.9 BOR 1.0 0.0 46.4 0.0 0.003 TL 19.00 PV Pipe: 19 -81.2 4.220 FL 6.00 PF 0.0 BOR 1.0 0.0 46.4 0.0 1.9 140 FTG E PR 1.7 DIP -3.0 0.0 48.1 0.0 0.001 TL 22.73 PV Pipe: 20 -81.2 4.230 PL 10.00 PF 0.0 DIP -3.0 0.0 48.1 0.0 1.9 150 FTG ---- PR -2.6 DA 3.0 0.0 45.5 0.0 0.001 TL 10.00 PV Pipe: 21 FIXED PRESSURE LOSS DEVICE DC 3.0 0.0 51.5 0.0 6.0 psi, 81.2 gpm DA 3.0 0.0 45.5 0.0 Pipe: 22 -81.2 4.230 FL 30.00 PR 0.1 DC 3.0 0.0 51.5 0.0 1.9 150 FTG TG PS 2.6 SRC -3.0 SRCE 54.2 (N/A) 0.001 TL 72.29 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\NA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2016) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.069 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 17.1 ft/sec at pipe 12. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node SRC under full flow conditions is 73.70 psi with a flow of 202.90 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEil ChkVlv Bfyvlv GatVlv AlmChk DPVlv NPTee 4.220 12.58 25.15 7.55 27.67 15.09 2.52 25.15 25.15 25.15 4.230 12.72 25.44 7.63 27.99 15.27 2.54 25.44 25.44 25.44 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Ell Tee 1.442 3.00 6.00 2.00 7.00 6.00 1.00 0.00 0.00 4.000 10.00 20.00 6.00 22.00 12.00 2.00 0.00 0.00 PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) H T R K C L B L Ell Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 1.394 8.00 6.00 1.00 0.00 1.00 2.00 0.00 2.00 60 .0 G A 2A U 50.0 G U E 40.0 P R 30.0 E S S 20.0 U R 10.0 F N". N" 'S. N". N" SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/18/2019F1L55\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR WATER SUPPLY ANALYSIS Static: 73.80 psi Resid: 35.10 psi Flow: 5225.0 gpm E:I,Ws] 1A 70.0 LEGEND Available pressure 73.72 psi @ 181.2 gpm Required pressure 54.24 psi @ 181.2 gpm Avail. OnSite Demand Press. 73.72 psi @ 81.2 gpm Req. OnSite Demand Press. 54.24 psi 8 81.2 gpm Source Supply Curve System Demand Curve Available at Source 12018002400 3000 3600 4200 4800 5400 6000 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results (2) On Site pressures are based on hose stream deduction at the source SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/18/2019FILES\HRS SYSTEMS\HASS87\HASS DATA\MA-01-015-3RD FLOOR.SDF JOB TITLE: MADISON AVENUE01-015-3rd FLOOR WATER SUPPLY CURVE 84+ 77+ 70+ \\ I \ I \ I \\ 63+ \ \ P56+ \ R X \\ E I \ S \\ 5 49+ \ U R I \\ E I \ 42+ \ \\ P1 SI I 35+ * <-35.1 psi 8 5225 gpm Flow Test Point 28+ 21+ 14+ LEGEND IT I IF I X = Required Water Supply if I 54.24 psi @ 181.2 gpm if 7+ IT I 0 = Available Water Supply if I 73.72 psi @ 181.2 gpm IF IT 0++-+---+----+-----+------+--------+--------+---------+-----------+ 16002400 3200 4000 4800 5600 6400 7200 8000 FLOW (GPM) tq Fire Protection Products Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 49 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFll Residential Sprinklers (TY2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFll Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The adjustment provided by the Recessed IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (1Y2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. NOTICE The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. JANUARY 2016 Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed (for use with wet pipe and dry pipe systems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 (Refer to the Design Criteria section for details on these approvals.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 gpm/psi112 (70,6 pm/ban/2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White, Signal White, or Chrome Plated Physical Characteristics Frame .............................Brass Button ...........................Copper Sealing Assembly.. Beryllium Nickel w/TEFLON Bulb (3 mm)........................Glass Compression Screw .................Bronze Deflector ..........................Bronze TFP400 TFP400 Page 2 of 6 7/16 (11,1 mm) 1/211 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 2-7/8' DIA._________ 1 - Frame MAKE-IN SURFACE (73,0 mm) 2 - Button 4-Bulb I 5 - Compression 2 2-1/4Screw 3 - Sealing Assembly 1 EON 1-5/8 6- Deflector* (57,2 mm) i ESCUTC' _______ STYLE 20 (41,3 mm) I w RECESSED * Temperature rating is 6* FLATS indicated on Deflector. CROSS SECTION PENDENT RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFll Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFll Residential Sprinklers (1Y2234) in dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically cal- culated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). TFP400 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coveraae Ordinary Temperature Rating Intermediate Temperature Rating Minimum Area ( 155°F (68°C) 175°F (79°C) Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (mx m) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 14 X 14 (4,3 x 4,3) 13 (49,2) 7.0 (0,48) 13 (49,2) 7.0 (0,48) 4 inches Recessed Beamed using Style 20 16x16 13 7.0 13 7.0 Ceilings per Escutcheon or 8 (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18 x 18 17 12.0 17 12.0 (5,5 x 5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x 6,1) (75,7) (1,15) (75,7) (1,15) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coveraae Ordinary Temperature Rating Intermediate Temperature Rating Area ( 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. Deflector to Installation Spacing (mxm) Flow Pressure Flow Pressure Ceiling Type Ft. gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12 x 12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4 inches Beamed Ceilings Recessed using Style 20 Escutcheon or 8 14x14 (4,3 x 4,3) 14 (53,0) 8.2 (0,57) 14 (53,0) 8.2 (0,57) 16x16 15 9.4 15 9.4 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 13D or13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18x18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 4 of 6 / CH RECESS (END A USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH - 2-7/8" DIA. p-I 7/16±1/8 (73,0 mm) I 1/2 (12,7 mm) (11,1±3,2 mm) 2-1/4 DIA. 1 /4 (6,4 mm) I FACE OF (57,2 mm) —11 S SPRINKLER MOUNTING FITTING PLATE I t t MOUNTING SURFACE 1/8 I (3,2 mm) 1-3/8" (34,9 mm) CLOSURE 1Y2234 1-1/8" (28,6 mm) FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH Installation TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step A. Install recessed pendent sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFll Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 5 of 6 Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII 4.9K Residential Pendent Sprinkler (1Y2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass .................51-201-1-155 Pure White (RAL 9010)° .........51-201-3-155 Signal White (RAL 9003) ........51 -201-4-155 Chrome Plated ................51-201-9-155 175°F (79°C) Natural Brass .................51-201-1-175 Pure White (RAL 9010)*51 -201-3-175 Signal White (RAL 9003) ........51-201-4-175 Chrome Plated ................51 -201-9-175 * Eastern Hemisphere sales only Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2016 Tyco Fire Products, LP. All rights reserved. TEFLON is trademark of the DuPont Corporation. tqco Fire Protection Products tqco? Fire Protection Products Worldwide Contacts www.tyco-fire.com RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description The TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are dec- orative, fast response, fusible solder sprinklers designed for use in residen- tial occupancies such as homes, apart- ments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFII Residential Con- cealed Pendent Sprinklers provides 1/2 in. (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprin- kler drops. The Series LFII Residential Concealed Pendent Sprinklers are intended for use in the following scenarios: Wet and dry pipe residential sprin- kler systems for one and two fam- ily dwellings and mobile homes per NFPA 13D Wet and dry pipe residential sprin- kler systems for residential occupan- cies up to and including four stories in height per NFPA 13R Wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The Series LFII Residential Concealed Pendent Sprinklers have been designed with heat sensitivity and water distri- bution characteristics proven to help IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 in the control of residential fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (1Y3596) are shipped with a Disposable Protec- tive Cap. The Protective Cap is tem- porarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Pro- tective Cap can also be used to mark the center of the ceiling hole into the plaster board, ceiling tiles, and so on, by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly is installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offer a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. DECEMBER 2017 L!L.1ILI The Series LFII Residential Concealed Pendent Sprinklers (Y3596) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the National Fire Protection Associa- tion (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 TFP442 TFP442 Page 2 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to all requirements of NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are Listed only when installed with LFII/RFlll Concealed Cover Plates having factory- applied finishes. Sprinklers and Cover Plates are separately ordered. Refer to the Ordering Procedure section for more information. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 GPM/psi½ (70,6 LPM/bar½) Temperature Rating 160°F (71°C) Sprinkler 139°F (59°C) Cover Plate Vertical Adjustment 1/2 in. (12,7 mm) Finishes Refer to Ordering Procedure section Physical Characteristics Body ..............................Brass Cap ..............................Bronze Saddle ............................. Brass Sealing Assembly.. Beryllium Nickel w/TEFLON Soldered Link Halves ................Nickel Lever .............................Bronze Compression Screw ..................Brass Deflector ..................Copper or Brass Guide Pin Housing ..................Bronze Guide Pins .........Stainless Steel or Bronze Support Cup .......................Steel Cover Plate .......................Copper Retainer ...........................Brass Cover Plate Ejection Spring . . . . Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Retainer at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link-halves separate allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (1Y3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, beamed, or sloped in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprin- kler flow rates are given in Tables A and B as a function of temperature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of 'design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. BODY SEALING (1/2 NPT) ___- ASSEMBLY CAP TV SADDLE if4Jr WRENCHING r SPRINKLER SUPPORT SCREW CUPWITH -1l N COMPRESSION ROLL FORMED I 1 THREADS LEVER GUIDE 13 1 PIN SOLDER LINK ELEMENT GUIDE PIN 7 HOUSING 'V H H I I I I i DEFLECTOR I I I DEFLECTOR / I:I11:I (OPERATED J I POSITION) SPRINKLER ASSEMBLY THREAD INTO I ___________________________I RETAINER SUPPORT WITH THREAD CUP UNTIL DIMPLES MOUNTING SURFACE IS FLUSH WITH CEILING EJECTION \ SPRING SOLDER -, COVER PLATE '-. COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) TFP442 Page 3 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure 2,3 Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area 160°F (71°C) Minimum Ft. x Ft. Ft. (m) Deflector to Installation Spacing Flow Pressure (mx m) Ceiling Type Ft. GPM psi (m) (LPM) (bar) 12x12 12 13 7.0 (3,7 x 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 14 x 14 14 13 7.0 7/8 to 1-1/8 in. (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 13 7.0 (4,9 X 4,9) (4,9) (49,2) (0,48) 13R, or 13. Installed in (2,4) 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8t0 1-1/8 in. below bottom 20 x 20 20 20 16.7 of beam (6,1 x 6,1) (6,1) (75,7) (1,15) Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum tow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 GPM/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TV3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure 2,3 Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area 160°F (71°C) Minimum Ft. x Ft. Ft. Deflector to Installation Spacing Flow Pressure (m x m) (m) Ceiling Type Ft. GPM psi (m) (LPM) (bar) 12x12 12 13 7.0 (3,7 x 3,7) (3,7) (49,2) (0,48) Smooth Ceilings 14 x 14 14 14 8.2 7/8 to 1-1/8 in. (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 15 9.4 (4,9x4,9) (4,9) (56,8) (0,65) 13R, or 13. Installed in (2,4) 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8t0 1-1/8 in. below bottom 20 x 20 20 21 18.4 of beam (6,1 x 6,1) (6,1) (79,5) (1,27) Notes: For coverage area dimensions less than or between those indicated, use the minimum required tow for the nest highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated us- ing the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 GPM/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 4 of 6 2-1/2 DIA. SPRINKLER- (635 mm) 1/2 (12,7 mm) FACE OF SUPPORT CUP 1/2 THREADED SPRINKLER ASSEMBLY ADJUSTMENT FITTING OPERATED SPRINKLER - COVER J NPT 1-7/8±1/4 PLATE (47,6 mm RETAINER 1/8 GAP ±6,4 mm) 7/8 COVER- SPRINKLER- f (22,2 mm) MOUNTING RETAINER SUPPORT CUP 3/16 SURFACE 1-1/8 (28,6 mm) ASSEMBLY ASSEMBLY I (4,8 mm) ______ - 3-3/16 DISPOSABLE DIA. I DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 2 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS, PROTECTIVE CAP, AND ACTIVATED DEFLECTOR Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Tables A and B as a function of temperature rating and the maximum allowable cover- age area A minimum discharge of 0.1 GPM/ft.2 over the design area comprised of the four most hydrauli- cally demanding sprinklers for actual coverage areas protected by the four sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operat- ing sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 2. Sprinkler Spacing The minimum spacing between sprin- klers is 8 ft. (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 ft. for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. Installation The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only. Therefore, do not apply pres- sure to the fusible Link Assembly. A 1/2 in. NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 ft-lb (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate Assembly by under-or over-tightening the Sprinkler. Re- adjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. WRENCH RECESS et PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 18 SPRINKLER WRENCH Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 3, install and tighten the Sprinkler! Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 in. ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." TFP442 Page 5 of 6 Step 5. After the ceiling has been com- pleted with the 2-1/2 in. (63 mm) diam- eter clearance hole and in preparation for installing the Cover Plate Assembly, remove and discard the Protective Cap, and verify that the Deflector moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Push on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to push on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 in. (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper oper- ation of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Res- idential Concealed Pendent Sprinkler, P/N 51-112-1-160 Note: Sprinkler and Cover Plates are separately sold. See below for Cover Plate ordering information. Cover Plate Assemblies Specify: LFIl/RFIII Concealed Sprinkler Cover Plate Assembly, (specify finish), P/N (specify): Ivory (RAL1015) ...............56-204-0-135 Beige (RAL1001) ..............56-204-2-135 Pure White (RAL9010)*56-204-3-135 Signal White (RAL9003). ........ 56-204-4-135 Grey White (RAL9002)..........56-204-5-135 Brown (RAL8028)..............56-204-6-135 Black (RAL9005) ..............56-204-7-135 Brushed Brass ................ 56-204-8 -135 Brushed Chrome ..............56-204-9-135 Brass .......................56-204-1-135 Custom Paint .................56-204-X-135 *Eastern Hemisphere sales only *Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 TFP442 Page 6 of 6 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 Copyright © 2018 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is a registered trademark of DuPont Fire Protection Products 1•' Worldwide www.tyco-fire.com Contacts Fire Protection Products Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 IAL.)tLg The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313 .....Upright 5.61K, 1/2" NPT Pendent 5.61K, 1/2" NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* 'The maximum working pressure of 250 psi (17.2 bar) Only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psV (80,6 LPM/bar½) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . .Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze JULY 2017 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON * 6 5 t 7/16 (11,1mm) WP _______ I NOMINAL (50_1\ ____ mm) MAKE-IN _____ :iiiiii (50,8 mm) 2 2 [V 1-3/8 ________ (34,9 mm) FI 1/2 NPT** DEFLECTOR * 2-7/8 (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 311. With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) "Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 - 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER FITTING 5/8 (15,9 mm) FLUSH \ _l 3/8±5/16" (9,5±7,9 mm) t / MOUNTING 1/8" J SURFACE 4(3,2 (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON - 2-7/8" DIA. - (73,0 mm) FACE OF SPRINKLER 2-1/4" DIA. FITTING - (57,2 mm) 5/16±1/4" \ 1/2"(12,7mm) (7,9±6,4 mm) FLUSH 17, MOUNTING \ 1/8" SURFACE /1 \_ (3,2mm) CLOSURE SERIES MOUNTING 1-3/8"(34,9mm) TYFRB PLATE 7/8 (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 1 I NATURAL BRASS PURE WHITE(RAL9O1O)** POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) POLYESTER 9 I CHROME PLATED P/N*77_XXX_ -xxx SPRINKLER TEMPERATURE FINISH I I RATINGS 135 135-F (57-q 155 155°F (68°C) 175 175°F(79°C) 200 200°F (93°C) 286 286-F (141-q ** Eastern Hemisphere sales only SIN 370 5.6K UPRIGHT (1/2" NPT) 1Y313 371 5.6K PENDENT (1/2" NPT) TY323 * Use suffix "I" for ISO 7-1 connection; for example, 77-370-4-175-I TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME PLATED POLYESTERC 135°F (57°C) Orange UPRIGHT (TY313) and 1, 2, 3, 4, 5, 6 155°F (68°C) Red 175°F (79°C) Yellow 5.6 1/2" NPT PENDENT (TY323) 200°F (93°C) Green 286°F (141°C) Blue ________________ 135°F (57°C) Orange RECESSED PENDENT (TY313) Figures 48 and 5b 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM( as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact TYCO Fire Protective Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06( as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2" NPT) 5/8" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20(1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446 1 Telephone +1-215-362-0700 Copyright © 2017 Tyco Fire Products, LP. All rights reserved. tqco TEFLON is a registered trademark of DuPont Fire Protection Products 7a§ 0 Fire Protection Products Worldwide www.tyco-fire.com Contacts Series TYIFRB - 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description The Series TY-FRB, 5.6 K-factor, Hor- izontal and Vertical Sidewall Sprin- klers described in this data sheet are quick response -standard cover- age, decorative 3 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commer- cial occupancies such as banks, ho- tels, shopping malls, etc. They are de- signed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The recessed version of the Series TY-FRB Horizontal Sidewall Sprin- kler is intended for use in areas with a finished wall. It uses a two-piece Style 10 Recessed Escutcheon with 1/2 inch (12,7 mm) of recessed adjust- ment or up to 3/4 inch (19,1 mm) of to- tal adjustment from the flush sidewall position, or a two-piece Style 20 Re- cessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cau- tions with respect to handling and installation of sprinkler sys- tems and components. Improp- er handling and installation can permanently damage a sprin- kler system or its components and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitabil- ity of these coatings for any given cor- rosive environment. The effects of am- bient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or sprinkler manufacturer with any questions. Sprinkler Identification Numbers TY3331 ...............Horizontal TY3431 ..................Vertical FEBRUARY 2014 Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A for complete approv- al information including corrosion re- sistant status.) Maximum Working Pressure Refer to Table B. Discharge Coefficient K=5.6 GPM/psi112 (80,6 LPM/bar1/2) Temperature Ratings Refer to Table A. Finishes Sprinkler: Refer to Table C. Recessed Escutcheon: Signal or Pure White, Jet Black, Chrome Plated, or Brass Plated. TFPI76 1 - Frame DEFLECT( HAT 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * q 9/16° WRENCH 1/2 ** (14,3 mm) FLATS NPT 1-13/16 7/16 46,0 mm) (11,1 mm) CENTERLINE NOMINAL I OF SPRINKLER MAKE-IN WATERWAY 1-1/2 38,1 mmi * Temperature rating 2-3/16 is indicated on Deflector. STYLE (55,6 mm) I ESCUTCHEON ** Pipe thread 10 or PLATE SEATING connections per I RECESSED SURFACE ISO 7-1 can be I ESCUTCHEON provided on I special request. 2-7/8' DIA. (73,0 mm) FIGURE 1 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TV3331) SPRINKLERS TFPI76 Page 2 of 6 Physical Characteristics Frame............................Bronze Button......................Brass/Copper Sealing Assembly ........Beryllium Nickel WI TEFLON Bulb ..............................Glass Compression Screw ................Bronze HSW Deflector .....................Bronze VSW Deflector .....................Copper Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers are intended for fire protection sys- tems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 10 or 20 Recessed Es- cutcheon, as applicable, is to be used for recessed horizontal installations. Installation The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) to 3/32 inch (2,4 mm) for the 286°F (141°C) temperature ratings. A leak tight 1/2 inch NPlsprinkler joint should be obtained with a torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprin- kler and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuf- ficient adjustment in the escutcheon plate by under-or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-FRB Horizontal and Vertical Sidewall Sprinkler Installation The Series TY-FRB Horizontal and Vertical Sidewall Sprinklers must be installed in accordance with the fol- lowing instructions. Step 1. Horizontal sidewall sprinklers are to be installed in the horizontal po- sition with their centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright po- sition with the arrow on the Deflector pointing away from the wall. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 5), With reference to Figure 1 or 2, the W- Type 6 Sprinkler Wrench is to be ap- plied to the wrench flats. SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION FIGURE 2 5.6 K-FACTOR QUICK RESPONSE SERIES TY-FRB VERTICAL SIDEWALL (TY3431) SPRINKLERS TFPI76 Page 3 of 6 Series TY-FRB Recessed Horizontal Sidewall Sprinkler Installation The Series TY-FRB Recessed Hori- zontal Sidewall Sprinklers must be installed in accordance with this section. Step A. Recessed horizontal sidewall sprinklers are to be installed in the horizontal position with their center- line of waterway perpendicular to the back wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Step B. After installing the Style 10 or 20 Mounting Plate over the sprinkler threads, hand tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 6). With reference to Figure 1, the W-Type 7 Recessed Sprinkler Wrench is to be applied to the sprin- kler wrench flats. Step D. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 or 20 Clo- sure over the Series TY-FRB Sprinkler and push the Closure over the Mount- ing Plate until its flange comes in con- tact with the ceiling. Care and Maintenance The Series TY-FRB, 5.6 K-factor, Hori- zontal and Vertical Sidewall Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection sys- tem main control valve for mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must be obtained from the prop- er authorities and all personnel who may be affected by this action must be notified. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced * Temperature ** Pipe thread rating is connections indicated on per ISO 7-1 can Deflector. be provided on special request. 7/16 ESCUTCHEON (11,1 mm) PLATE SEATING NOMINAL SURFACE 1/2 ** MAKE-IN NPT if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section). The owner must assure that the sprin- klers are not used for hanging any ob- jects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprin- klers, after the installation has been completed, to verify the integrity of the corrosion resistant coating. Thereaf- ter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive condi- tions present. 1 - Frame 4 - Bulb 7 - Ejection 2 - Button 5 - Compression Spring 3 - Sealing Screw Assembly 6 - Deflector* ARROW MUST POINT AWAY FROM AND BE The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association (e.g., NFPA 25), in addition to the standards of any oth- er authorities having jurisdiction. The installing contractor or sprinkler man- ufacturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, test- ed, and maintained by a qualified In- spection Service in accordance with local requirements and/or national codes. PERPENDICULA R TO THE BACK WALL SURFACE TFPI76 Page 4 of 6 5/8±1/4 - (15,9±6,4 mm) MOUNTING FACE OF SURFACE ___ SPRINKLER FITTING CLOSURE - 2-7/8 DIA. SERIES (73,0 mm) TY-FRB /4"" j ° DIA. mm) I MOUNTING PLATE 1/8° (3,2 mm) 1-1/4(31,8mm) 3/4(19,1 mm) 3/4 (19,1 mm) 1/4° (6,4 mm) FIGURE 3 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 1/2±1/8" (12,7±3,2 mm) MOUNTING FACE OF SURFACE SPRINKLER FITTING CLOSURE 2-7/8° DIA. SERIES TY-FRB __jj 21 (73,0 mm) DIA. / (5 12 MOUNTING PLATE 1/8" (3,2 mm) 1-1/4(31,8mm) 1/2(12,7mm) 1"(25,4 mm) 1/4"(6,4 mm) FIGURE 4 SERIES TY-FRB RECESSED HORIZONTAL SIDEWALL SPRINKLER WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON WRENCH RECESS (END "A° USED FOR 60 1/2° NPT MODELS) FIGURE 5 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS )R;3 PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 6 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI76 Page 5 of 6 SPRINKLER FINISH (See Note 11) K TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED POLYESTER*** LEAD COATED 135°F (57°C) Orange 155°F (68°C) Red HORIZ. 175°F (79°C) Yellow SIDEWALL 1, 2, 3,4, 9, 10 1, 2,3, 9 1, 2, 3,9 (1Y3331) 200°F (93°C) Green 286°F (141°C) Blue 5.6 1/2" NPT RECESSED HORIZ. SIDEWALL (TY3331)* 135°F (57°C) Orange 1, 2, 4, 9, 10 1, 2, 9 N/A 155°F (68°C) Red 175°F (79°C) Yellow Figure 3 Green 200°F (93°C) RECESSED 135°F (57°C) Orange 155°F (68°C) Red HORIZ. SIDEWALL (TY3331)** 1,2, 3,4,9 N/A 175°F (79°C) Yellow Figure 4 Green 200°F (93°C) VERTICAL 135°F (57°C) Orange 155°F (68°C) Red 5.6 1/2" SIDEWALL Installed 5, 6, 7, 8, 9 5, 6, 7, 9 175°F (79°C) Yellow NPT - Pendent or Upright Blue 200°F (93°C) Green 286°F (141°C) NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Listed by Underwriters Laboratories Inc. for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies at a 4 to 12 inch(100 to 300 mm) top of deflector to ceiling distance. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies at a 4 to 12 inch (100 to 300 mm) top of deflector to ceiling distance. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007a/04) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. Listed by Underwriters Laboratories, Inc. as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. Listed by Underwriters Laboratories for use in Canada (C-UL) as Quick Response Sprinklers for use in Light and Ordinary Hazard Occupancies. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers for use in Light Hazard Occupancies. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106 & 007a104) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) at a 4 to 6 inch (100 to 150 mm) top of deflector to ceiling distance. The LPC does not rate the thermal sensitivity of horizontal sidewall sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resis-tant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2° NPT) 3/4° Total Adjustment Recessed Escutcheon. ** Installed with Style 20 (1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon. Frame and deflector only. TABLE A LABORATORY LISTINGS AND APPROVALS TFPI76 Page 6 of 6 SPRINKLER FINISH K TYPE NATURAL BRASS I CHROME PLATED I POLYESTER LEAD COATED HORIZONTAL SIDEWALL 250 PSI (17,2 BAR) (TY3331) or 175PS1 (12,1 BAR) RECESSED HORIZ. SIDEWALL (TY3331) 5.6 (SEE NOTE 1) NPT VERTICAL SIDEWALL 17 1 5 PSI (2,1 BAR) (TY3431) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL); the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and, the Approval by the City of New York. TABLE B MAXIMUM WORKING PRESSURE P/N 57 - XXX - X - XXX I I I SIN I SPRINKLER i I TEMPERATURE I FINISH I I I RATINGS I 378 I HORIZONTAL SIDEWALL I TY3331 1 NATURAL BRASS 135 135°F (57°C) 375 VERTICAL SIDEWALL 3431 PURE WHITE (RAL9O1O)° 155 155°F (68°C) POLYESTER SIGNAL WHITE (RA19003) 175 175°F (79°C) POLYESTER - JET BLACK (RAL9005)** 200 200°F (93°C) POLYESTER 7 LEAD COATED 286 286°F (141°C) 9 I CHROME PLATED * Eastern Hemisphere sales only. Available in 155°F (68°C) or 200°F (93°C) temperature rating only. TABLE C PART NUMBER SELECTION SERIES TY-FRB HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indi- cate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections: Specify: Series TY-FRB (specify SIN), (specify K-factor), (specify) Horizontal Sidewall or Vertical Sidewall Sprinkler, Standard Response, Standard Cov- erage, (specify) temperature rating, (specify) finish or coating, P/N (spec- ify from Table C) Recessed Escutcheon Specify: Style (10 or 20) Recessed Es- cutcheon with (specify*) finish, P/N (specify*). Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2013 Tyco Fire Products, LP. All rights reserved. talc TEFLON is trademark of The DuPont Corporation. Fire Protection Products