HomeMy WebLinkAbout5791 VAN ALLEN WAY; ; FPC2022-0101; PermitLcityof PEERMXT REPORT Carlsbad FeiI?eiirnt Print Date: 06/16/2022 Permit No: FPC2022-0101 Job Address: 5791 VAN ALLEN WAY, CARLSBAD, CA 92008-7321 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121304500 Track #: Applied: 05/26/2022 Valuation: $768,000.00 Lot #: Issued: 06/08/2022 Occupancy Group: Project #: Finaled Close Out: 06/16/2022 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix Plan Check #: Project Title: Description: THERMO FISHER -SPRINKLER TI FOR LAB EXPANSION (10 HEADS) Applicant: FPContractor: WESTERN FIRE PROTECTION INC WESTERN FIRE PROTECTION INC MARIO MACK 13630 DANIELSON ST 13630 DANIELSON ST P0 WAY, CA 92064-6830 POWAY, CA 92064-6830 (858) 513-4949 (858) 513-4949 FEE AMOUNT FIRE NFPA 13 or 13R System 7-100 heads $607.00 Total Fees: $607.00 Total Payments To Date: $607.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1760-602-4665 760-602-8561 f I www.carlsbadca.gov I I o Western Fire Protection Inc. I Thermo Fisher PD Lab Expansion 5791 Van Allen Way Carlsbad, CA 92008 Western Job# 22-2265-03 FIRE SPRINKLER SYSTEM MATERIAL DATA SUBMITTAL I L [1 I I I I DUE TO AVAILABILITY, MATERIAL MAY BE SUBSTITUTED FOR LIKE EQUIVALENT I I 13630 Danielson Street • Poway, CA 92064 • Phone: (858) 513-4949 • Fax: (858) 513-1322 I I [I I I I I I Victaulic® FireLockTM Series FL-QR Standard Coverage, Quick Response Upright, Pendent and Recessed Pendent Sprinklers ,htauiicr I K2.8 (4.0)9 K4.2 (6.1)9 K5.6 (8.1), K8.0 (11.5) 41.01 I Adlill 1.0 PRODUCT DESCRIPTION QUICK RESPONSE UPRIGHT SPRINKLERS SIN V2815 V4215 V2704 V3402 ORIENTATION UPRIGHT UPRIGHT UPRIGHT UPRIGHT KFACTOR' 281mp/4051 421mp/6151 561mp/8151 80lmp/11551 CONNECTION ½" NPT/115mm BSPT ½" NPT/i5mm BSPT ½" NPT/15mm BSPT/IGS 1/4" NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 psi/1 200 kPa 175 psi/i 200 kPa 175 psi/ 1200 kPa cULus25O psi /1725kPa 175 psi/1200 kPa GLOBE RE-DESIGNATION GL2815 GL4215 - - GLOBE EQUIVALENT - - GL5615 GL8118 QUICK RESPONSE PENDENT SPRINKLERS SIN V2801 V4201 V2708 V3406 ORIENTATION PENDENT PENDENT PENDENT PENDENT KFACTOR' 28ImpJ40St 42Impi61SI 56ImpI81SI 80lmp/115SI CONNECTION ½" NPT/15mm BSPT ½" NPT/15rnm BSPT ½" NPT/15mm BSPT/IGS 1/4" NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 p51/1200 kPa 175 psi /1200 kPa 175 psi /1200 kPa cULus 250 psi/1725 kPa - 175 psi/1200 kPa GLOBE RE-DESIGNATION GL2801 GL4201 - - GLOBE EQUIVALENT - GL5601 GL8101 QUICK RESPONSE RECESSED PENDENT SPRINKLERS SIN V2801 V4201 V2708 V3406 ORIENTATION PENDENT PENDENT PENDENT PENDENT K-FACTOR' 2.81mpi4.0S.I. 4.21mpi6.1 S.I. -- 5.61mpf8.1 5.1: - 8.0lmp./11.55.I. CONNECTION ½" NPT/15mm BSPT ½" NPT/15mm BSPT ½" NPT/lsmm BSPT/IGS 1/4" NPT/20mm BSPT/IGS MAX. WORKING PRESSURE 175 psi/1 200 kPa I 175 psi/1 200 kPa 175 psi/1 200 kPa cULus 250 psi/1 725 kPa 175 psi/i 200 kPa ESCUTCHEON Recessed Recessed Recessed Recessed GLOBE RE-DESIGNATION GL2801 - GL4201 - - GLOBE EQUIVALENT I GL5601 GL8101 AVAILABLE GUARDS/SHIELDS SPRINKLER V28 V42 V27 V34 Upright ] U U Pendent J - U AVAILABLE WRENCHES SPRINKLER V56-2 Recessed V56 Open End V27-2 Recessed V27 Open End V34-2 Recessed V34 Open End 3/,6 Hex-Bit V2815 and V4215 U V2707 and V2704 U U V3402 V2801, and V4201 V2706 and V2708 V3406 L U - A L I Factory Hydrostatic Test: 100% @ 500 psi/3447 kPa/34 bar Mm. Operating Pressure: UL/FM: 7 psi/48 kPa/.5 bar VdS: 5 psi/35 kPa/.35 bar (Upright only) I Temperature Rating: See tables in section 2.0 1 For K-Factor when pressure is measured in bar, multiply S.I. units by 100. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. I s victauliccom 41.01 16343 Rev C Updated 04/2021 © 2021 Victaulic Company. All rights reserved. 1 ictaulic I I I I I I I I I I I I 2.0 CERTIFICATION/LISTINGS UPRIGHT APPROVALS/LISTINGS SIN V2815 V4215 V2704 V3402 Nominal <Factor Imperial 2.8 4.2 5.6 8.0 Nominal KFactor SI.2 4.0 6.1 8.1 11.5 Orientation UPRIGHT UPRIGHT UPRIGHT UPRIGHT Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 175°F/79°C 175°F/79°C 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C 286'F/1 41'C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C FM - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C LPCB - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/1 41°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C CE - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/1 41°C 286°F/1 41°C 135°F/57°C 135°F/57°C i 55°F/68°C 155°F/68°C VdS - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/141°C - 286°F/141°C CCC 155°F/68°C 155°F/68°C K-ZSTZ - - 286°F/141°C 286°F41*C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. PENDENT APPROVALS/LISTINGS SIN V2801 V4201 V2708 [ V3406 Nominal K Factor Imperial 2.8 4.2 5.6 8.0 Nominal K Factor SI.2 4.0 6.1 8.1 11.5 Orientation -. PENDENT PENDENT PENDENT - PENDENT Escutcheon Flush/Extended Flush/Extended Flush/Extended Flush/Extended Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 135°F/57°C 135°F/57°C I 55°F/68°C 155°F/68°C 155°F/68°C 155°F/68°C cULus 175°F/79°C i 75°F/79°C 175°F/79°C 175°F179°C 200°F/93°C 200°F/93°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C 286F/141°C 286°F/141°C 135°F/57°C 135°F/57°C 155°F/68°C 155°F/68°C FM - - 175°F/79°C 175°F/79°C 200°F/93°C 200°F/93°C 286°F/141°C 286°F/141°C CCC 155°F/68°C 155°F 68°C K-ZSTX - - 200°F/93°C 286°F141°C 286°F/141°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTES Listings and approval as of printing. Where cULus Listed, Polyester and VC-250 Coatings Listed as Corrosion Resistant (V3402 with VC-250 Only) Where FM Approved, VC-250 Coating Approved as Corrosion Resistant New York City Acceptance - All UL Listed and/or FM Approved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the OTCR Rule. 41.01 16343 Rev C Updated 04/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 _1taulic 2.0 CERTIFICATION/LISTINGS (CONTINUED) RECESSED PENDENT APPROVALS/LISTINGS SIN V2801 V4201 V2708 V3406 Nominal K Factor Imperial 2.8 4.2 5.6 8.0 NominalKFactorSl 2 40 61 81 115 Orientation PENDENT PENDENT PENDENT PENDENT Escutcheon Recessed Recessed Recessed Recessed Approved Temperature Ratings F°/C° 135°F/57°C 135°F/57°C 1 °F 7° 135°F/57°C 155°F/68°C 155°F/68°C 1 55°F'68°C 155°F/68°C cULus 175°F/79°C 175°F/79°C 175Fa,.. • 175°F/79°C 200°F/93°C 200°F/93°C 200 93 200°F/93°C 286°F/141°C 286°F/141°C 286°F/141°C FM 135°F/57°C 135°F/57°C WITH ½" ADJUSTMENT - - ESCUTCHEON ONLY 200°F/93°C 200°F/93°C CCC 155°F/68°C K-ZSTX - - / 286°F/i 41°C 2 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10. NOTES Listings and approval as of printing. Where cULus Listed, Polyester and VC-250 Coatings Listed as Corrosion Resistant (V3402 with VC-250 Only) Where FM Approved, VC-250 Coating Approved as Corrosion Resistant New York City Acceptance - All UL Listed and/or FM Approved sprinklers acceptable to NYC per section 28-113 of the Administrative Code and the OTCR Rule. I I I I I I I I I I 41.01 16343 Rev C Updated 04/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 \LtauIic I I I I I I F~ I Frame Lodgement spring Pip cap and spring seal Bulb Load screw Deflector 33 mm 1Il6/ 37 mm Load screw Bulb Pip cap and spring seal Lodgement spring 19A6/ Deflector 40 mm Load screw Bulb Pip cap and spring seal Lodgement spring Frame - Vf/l3mm Nominal make-in 21/f/ 63 mm 2½! 63 mm ½"/13 mm Nominal make-in 57 mm 0%V11 mm Nominal make-in 17A6"! 37 mm Load screw Bulb Pip cap and spring seal 2½"! Lodgement spring 63 mm Frame victaulic.com 3.0 SPECIFICATIONS - MATERIAL Deflector: Bronze Bulb Nominal Diameter: 3.0mm Load Screw: Bronze Pip Cap: Bronze Spring Seal: PTFE coated Beryllium nickel alloy Frame: Brass Lodgement Spring: Stainless steel Installation Wrench: Ductile iron Sprinkler Frame Finishes: Plain brass Chrome plated White polyester painted34 Flat black polyester painted34 Custom polyester painted34 VC-2505 Not available on the Intermediate Level Style Pendent. UL Listed for corrosion resistance. UL Listed and FM Approved for corrosion resistance. NOTE For cabinets and other accessories refer to separate sheet. 516/11mm Nominal make-in Lodgement spring Pip cap and spring seal 2A6'7 Bulb 58 mm Load screw Frame Deflector 31 I/Mm 37mrn Load screw Bulb Pip cap and spring seal Lodgement spring 63 mm L 1/2713 mm Nominal make-in L 1/2713 mm Nominal make-in 41.01 16343 Rev c Updated 04/2021 © 2021 Victaulic company, All rights reserved. victaulic.com 4 T_14jtaUIiC victaulic.com 4.0 DIMENSIONS 2W160 mm 2"/51 mm - Hole in ceiling I I I I I I I I I I I I I I I I I I I ½722 mm Max. (34" Adj.) mm 14"/3 mm Min. S, All 11 1 9 11 Typical ceiling 1Y8"/29 mm Mm (3/4" Ad)) 13/8"/34 mm Mm. (½" Adj.) I I ~\A/) - Finished surface 1'/8'/47 mm Max. I 2516775 mm 235'/60 mm 2"/51 mm - Hole in ceiling W/16 mm Max. (½" Adj.) %722 mm Max. (~ Ad).) Ia"!3 mm Mm. Typical ceiling Finished surface 154"/47 mm Max k 2'3A6775 mm 1W729 mm Mm. (3/4" Ad).) 1W/34 mm Mm. (½" Ad).). 21/a"/60 mm - 2751 mm -H Hole in ceiling 1/25 mm Max. (Y4' Ad).) 1/4'/19 mm Max. 0/2" Adj.) 1/4"/5 mm Mm. Typical ceiling all 13A6/30 mm Mm. (½" Ad).) 3Aa"/24 mm Mm. ('/," Ad).) Finished surface 111/6 /43 mm Max. 2'A6"/75 mm 41.01 16343 Rev C Updated 04/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 5 \4taulic(1 victaulic.com 5.0 PERFORMANCE Sprinkler is to be installed and designed as per NFPA, FM Datasheets, or any local standards. I 6.0 NOTIFICATIONS Ak ~W_-V "a NV17!"~ US Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depressur- ized and drained immediately prior to installation, removal, adjust- ment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain important information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. It is the system designer's responsibility to verify suitability of materials for use with the intended fluid media within the piping system and external environment. The material specifier shall evaluate the effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on materials to confirm system life will be acceptable for the intended service. Failure to follow installation requirements and local and national codes and standards could compromise system integrity or cause system failure, resulting in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Ratings: All glass bulbs are rated for temperatures from -670F/-550C to those shown in the table below. -40: Victaulic FireLocklM Automatic Sprinklers Installation and Maintenance Instructions I49: Style V9 Victaulic FireLockTM IGSTM lnstallation Read ynM Sprinkler Coupling Installation Instructions User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products for a particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, as well as Victaulic performance, maintenance, Victaulic reserves the right to change product specifications, designs and standard safety, and warning instructions. Nothing in this or any other document, nor any verbal equipment without notice and without incurring obligations. recommendation, advice, or opinion from any Victaulic employee, shall be deemed to Installation alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions Reference should always be made to the Victaulic installation handbook or installation of sale, installation guide, or this disclaimer, instructions of the product you are installing. Handbooks are included with each shipment Intellectual Property Rights of Victaulic products, providing complete installation and assembly data, and are available No statement contained herein concerning a possible or suggested use of any material, in PDF format on our website at www.oictaulic.com. product, service, or design is intended, or should be constructed, to grant any license Warranty under any patent or other intellectual property right of Victaulic or any of its subsidiaries Refer to the Warranty section of the current Price List or contact Victaulic for details. or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual Trademarks property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic and all other Victaulic marks are the trademarks or registered trademarks of or patent applications for articles and/or methods of use in the United States and/or other Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. countries. 41.01 16343 Rev C Updated 04/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com \4taulic Li I Victaulic® VicFlexTM Sprinkler Fittings I (ries AH2and AH2-CC Braided Flexible Hoses \4tauiicr 10.85 Fle)(m 1 Series Al-12 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component I Series AH2 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. Note: length includes adapter nipple and 5.75/140 mm straight reducer. Series AH2-CC 1"/DN25 ID Braided Hose: 31, 36, 48, 60, 72/790, 915, 1220, 1525, 1830 mm. I Note: length includes captured coupling and 5.75/140 mm straight reducer. Connections From Branchiine I • 34"/20mm BSPT female thread (VdS only) 1 1/4"/32mm BSPT female thread (LPCB only) I . 1/25mm NPT or BSPT female Thread 1"/25mm Grooved IGS (refer to Submittal 10.54 for additional IGS connections) I . No. 116 CPVC Adapter (1/25mm Female CPVC Socket x 1"/25mm Grooved IGS) No. 142 Welded Outlet Style 922 Outlet-I I • Style 920N Mechanical-I Outlet . No. 65 Grooved End of Run Fitting 1 . Hose Inlet 1/25mm Grooved IGS 1/25mm NPI or BSPT male thread I • 3%"/20mm BSPT male thread (VdS only) 1 '/4"/32mm BSPT male thread (LPCB only) I ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. p System No. Location Spec Section Paragraph Submitted By Date Approved Date victaulic.com 10.855839 Rev AK Updated 03/2021 © 2021 victaulic Company. All rights reserved. 1 Ai—c--taul—icr Uir+,I Ilir mm 1.0 PRODUCT DESCRIPTION (CONTINUED) Sprinkler Reducer Sprinkler Connection: ½" and 3/4°/l5mm and 20mm NPT or BSPT female thread Straight Lengths: 5.75", 9", 13/140mm, 230mm, 330mm 900 Elbows Standard Short Low Profile Short Standard Long Low Profile Long (Short elbows typically used with concealed sprinklers. Long elbows typically used with recessed pendent sprinklers) Brackets Style A132 for suspended and hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place Style A133 for surface mount applications, wood, metal and block walls, or ceilings Style A134 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment Style ABS for hard-lid ceilings and sidewalls, allows for vertical sprinkler adjustment Style A137 for suspended and hard-lid ceilings Style A137 Adjustable for suspended and hard-lid ceilings Style AB10 for Armstrong® TechZoneT ceilings Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 900 low profile elbows) Style AB12 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and allows for low profile installation down to 47100mm. Style ABBA bracket for suspended, exposed, and hard-lid ceilings Style ABMM bracket for surface mount and stand off-mount applications, wood, metal and block walls, or ceilings and hard-lid ceilings • Strut channel and pipe clamp, not supplied by Victaulic Maximum Working Temperature 225°F/107°C 150°F/65°C (No. 116 CPVC Adapter) Maximum Working Pressure 200 psi/1375 kPa (FM Approval) 175 psi/1206 kPa (cULus Listed) 1600 kPa/232 psi (VdS/LPCB Approved) 1.4 MPa (CCCf Approved) 175 psi/1206 kPa (No. 116 CPVC Adapter) Minimum Bend Radius 7/178mm (FM/CCCf Approval) 2/51 mm (cULus Listed) 3/76.2 mm (VdS/LPCB Approved) 10.85 5839 Rev AK updated 03/2021 © 2021 victaulic company. All rights reserved. iirt,.uIir mm f'taUIic victaulic.com 1.0 PRODUCT DESCRIPTION (CONTINUED) Maximum Allowable Sprinkler K-Factors FM (1/2715mm reducer) K5.6/8,1 (SI.), (3/4720mm reducer) K14.0/20,2 (SI.) cULus (1/2715mm reducer) K8.0/11,5 (SI.), (34720mm reducer) K14.0/20,2 (SI.) VdS/LPCB (1/2°/15mm reducer) K5.6/8,1 (Si.), (314720mm reducer) K8.0/11,5 (SI.) 2.0 CERTIFICATION/LISTINGS C US FVdS] L OPC B 0 LISTED NOTE The VicFlexSeries AH2 Hose has been tested and evaluated by Spears® for acceptable use with Spears® CPVC Products and is therefore covered under the Spears® FlameGuard® Installer Protection Plan. 3.0 SPECIFICATIONS - MATERIAL Series AH2: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Nut and Nipple: Carbon Steel, Zinc-Plated Reducer (V2715 mm or 3/4720 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Brackets: Carbon Steel, Zinc-Plated Series AH2-CC: Flexible Hose: 300-series Stainless Steel Collar/Weld Fitting: 300-series Stainless Steel Gasket Seal: Victaulic EPDM Isolation Ring: Nylon Coupling Retainer Ring: Polyethelene Nut: Carbon Steel, Zinc-Plated Reducer (V2715 mm or 3/4720 mm): Carbon Steel, Zinc-Plated Low Profile Elbows: Ductile Iron, Zinc-Plated Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: Orange enamel (North America, Asia Pacific). Red enamel (Europe). Hot dipped galvanized. Gasket:' Grade "E" EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish No. 116 Adapter Fitting: CPVC and Brass Seal: Victaulic EPDM 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 ___________ I I I I I I Ll I I ~11 I I I I I I I I I victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose L —o II•UifI liiW I [I UJII - --i Hose Length Dimensions Hose Length A B inches inches inches mm mm mm 31 25.3 31 790 641 790 36 31.3 36 915 794 915 48 42.3 48 1219 1073 1220 - 60 54.3 60 1525 1378 1525 72 66.3 72 1830 1683 1830 Series AH2-CC Braided Hose -I: Hose Length A B inches inches inches mm mm mm 31 24.5 29.8 790 - 622 757 36 29.5 34.8 915 749 884 48 415 46.8 _1219 1054 1189 60 53.5 58.8 1525 11359 -- 1494 72 65.5 70.8 1830 1664 . 1798 Item Description Flexible Hose Isolation Ring Gasket 4 Nut Adapter Nipple 6 1 Braid - Collar/Weld Fitting Sleeve Reducer Item Description 1 - Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut Captured Coupling - 6 Braid Collar/Weld Fitting 8 Sleeve 9 Reducer 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 \js'tauIic I I I I I I I I I I I I I I I I 1 I I victaulic.com 4.0 DIMENSIONS (CONTINUED) Standard Reducer 575/140 mm straight reducer Optional Reducers 2.62"! 66.5 mm 2.62"! 66.5 mm III llll ll1J1llhIi E115.507 1 139.7 mm I 9.0/229 mm straight reducer 4.83"! 122.7 mm 11I'1llIIll1llllIllIll1ll E1II I I 13.0/330 mm straight reducer Short 90° elbow reducer Long 90° elbow reducer NOTE The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. FM/VdS Approved only. Low Profile 1.88'! 48 mm 3.50"! 3.637 2.84/ 89 mm 92 mm 72 mm I 525"! 4.59 133 mm 1.4"! 1.47 36mm 36mm Short 90° elbow reducer Long 90° elbow reducer NOTE Style AB11: When low profiles elbows are with the Style AB11 bracket, the Low Profile Short Elbow is typically used with concealed sprinklers while the Low Profile Long Elbow is typically used in the installation of recessed pendent sprinklers. No. 116 CPVC Adapter NOTES E to E is 3.0/76.0 mm The No. 116 CPVC Adapter has 2 ft. (0.6 m) EQL of 1 Schedule 40 pipe. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 5 j4tauiir 7.257 184.2mm 6.57"! 166.9 mm 5.007 127.0 mm 3.257 82.6 mm victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB2 Suspended Ceilings Hard-Lid Ceilings Item Description r 1 24"/610mm or48"/1219mm Square Bar L 2 Patented Vertically Adjustable Center Bracket 1 31 - End Bracket NOTE Both sizes FM/VdS/LPCB Approved, cULus listed Style AB3 Surface Mount Applications FM/LPCB Approved Style AB4 Hard-Lid Ceilings with Hat furring channel grid system { Item Description - 1 24'7610 mm or 48'71219 mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel NOTE Both sizes FM/VdS/LPCB Approved, cULus listed. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 6 ___________ Style AB7 Adjustable Suspended Ceilings Hard-Lid Ceilings Litem Description 1 700mm or 1400mm Square Bar L. 2 Patented 1 -Bee2l Center Bracket 3 End Bracket (adjustable) NOTE Both sizes FM/VdS/LPCB Approved. I I I I I I I I victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB5 Hard-Lid Ceilings Item Description - 24/610mm 0r48/1219mm Square Bar 2 Patented Vertically Adjustable Center Bracket 3 .. End Bracket NOTE Both sizes FM/VdS/LPCB Approved, cULus listed. Style AB7 Suspended Ceilings Hard-Lid Ceilings Item Description 1 24/610mm or 48/1219mm Square Bar 2 Patented 1-Beer Center Bracket 3 End Bracket NOTE Both sizes FM/VdS/LPCB Approved. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 7 A-s-tau-Iie I I I I I I I Style AB11 Suspended ceilings Hard-Lid ceilings Item Description '/610 mm 0r48"/1219mm Square Bar L Patented 1-Bee2 Center Bracket L 3 End Bracket NOTE FM/VdS Approved, cULus listed. 4.3 DIMENSIONS VicFlex Brackets Style AB1O Suspended ceilings Armstrong® TechZoneTM Item ] Description - - i 6"/152 mm Square Bar - Patented 1-Bee2 Center Bracket [_3 I End Bracket NOTE FM/Vd5/LPCB Approved, cULus listed. Style AB12 Suspended ceilings Hard-Lid ceilings Item Description 1 Style AB1 2 Bracket Body, 2 #2 Square Drive Set Screw NOTE FM/VdS Approved. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 8 11., Ai-c-t-sub-cr I Style ABMM I . Surface mount Stand-off mount Item Description Style ABMM Bracket Body 2 p Screw, Serated Flange, M6 x 1 x 15.24 T25 Torx Drive Recessed I victaulic.com 4.3 DIMENSIONS (CONTINUED) VicFlex Brackets Style ABBA Floor-above mount Cantilever mount Temporary mount in exposed ceilings Item Description 1 Style ABBA Mounting Plate 2 Style ABBA Square Bar Cap Screw, Serated Flange, M6 x 1 x 20, T25 Torx Drive Recessed 4 Style ABMM Bracket Body Cap Screw, Serated Flange, M6 x 1 x 15.24, 125 Torx Drive Recessed NOTE FM Approved. I I I I I I I NOTE FM Approved. I I I I I I I I 10.85 5839 Rev AK Updated 03/2021 © 2021 victaulic Company. All rights reserved. I victaulic.com g \,staulic 4.3., 111 mm 23,h'760.33 mm V2707 MAX. EXTENSION victaulic.com 4.4 DIMENSIONS Clearances Series AH2 Braided Hose and Style A132 Bracket ab L Bracket Assembly Style AB2 Willi 1/8715.9 mm I I — Typical iling I lp ii= .j - - .,.n',,/il/,,zue',ze7i,/, Finished See note [ T \_ _____________ 24'/610 mm 0r48"/1219 mm surface on Center V2707 "/4"Il9 MM MAX. RECESS Hose Clearance Chart Straight Reducer Long Elbow Short Elbow V2707 V3802 V2707 V3802 3/4' ½' 3/4" ½" V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess 3/4" Max Recess ½" Max Recess 3/4" Max Recess ½" Max Recess inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 20 3.0 7.0 Bend Radius 50 80 - 175 "A" Minimum Required 8.6 10.1 9.6 11.1 13.6 15.1 5.8 5.8 Installation 218 269 244 281 345 383 147 147 Space _____ NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 10 j(cittauiic. 2"x4 Stud Typical 167406 mm C/C - V381/2'713 mm MAX. RECESS Screw Bracket Assembly Style AB2 L.. — - U I I I I I I I I I I I I I I I I I I victaulic.com 4.5 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB2 Bracket See chart A See Chart 2'A6768 mm 1.874 max. hole - 21W/60 mm I I win, hole I I I I I I I I 3½"! 89 mm I I t Finished /8/16 mm J ceiling Typical drywall V38 MAX. EXTENSION Hose Clearance Chart Straight Reducer V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 3/4" 120mm ½" 113mm /4°I 20mm /4'I 20mm ½' 113mm WI 20mm WI 20mm ½" 113mm WI 20mm Max Recess" Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 "A" Minimum Required 6.2 7.6 6.1 7.2 8.6 7.1 11.2 12.6 11.1 Installation 158 193 155 183 218 180 285 320 282 Space ___________ Hose Clearance Chart Long Elbow Short Elbow V2707 V2709 V3802 3/4 I20mm 3/4 120mm ½"ll3mm Max Recess Sidewall Max Recess inches inches inches mm mm mm "R" Minimum - Bend Radius "A" Minimum Required 3.3 3.6 3.3 Installation 84 91 84 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 11 '%ItauIic 2W/60 mm max. hole V27 MAX. EXTENSION victaulic.com 4.6 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB4 Bracket A See Chart See chart Bracket assembly Style AB4 Typical 16/406 mm C/C V27 /4"/19 mm MAX. RECESS 4.1/ 104 mm 1/8723 mm inished /8'716 mm ceiling Typical drywall Hose Clearance Chart Straight Reducer ___________ Long Elbow Short Elbow V2707 V3802 V2707 V3802 ~" ½" ~" 1h.. V2707 V3802 V2707 V3802 Max Recess Max Recess Max Recess Max Recess ~" Max Recess ½" Max Recess 3/4!' Max Recess ½" Max Recess inches inches inches inches inches ' inches inches inches mm mm mm mm mm mm mm mm "R" Minimum 2.0 2.0 3.0 3.0 7.0 7.0 Bend Radius 50 50 80 80 175 175 - "A" Minimum Required 8.8 10.2 9.8 11.2 13.8 15.2 8.0 5.9 Installation 224 259 249 285 351 386 203 150 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 12 '4tau1ic 2W/60 mm max. hole Wi MAX. EXTENSION I I I I I I I I I I I I I I I I I I I victaulic.com 4.7 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB5 Bracket 4R I See chart A See chart Bracket assembly Style ABS 2.37 I 57 mm — __ mbly ___T H 3L 92mm H I oi,ed T " A' '716mm ceiling Typ. Drywall —Typical 167406mmC/C— V27 %"I19 mm MAX. RECESS Hose clearance Chart Straight Reducer "V2707 V3802 V2709 V2707 V3802 V2709 V2707 V3802 V2709 WI 20mm WI 13mm WI 20mm WI 20mm WI 13mm /4'I 20mm WI 20mm WI 13mm WI 20mm Max Recess' Max Recess Sidewall Max Recess Max Recess Sidewall Max Recess Max Recess Sidewall inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm "R" Minimum 2.0 3.0 7.0 Bend Radius 50 80 175 'A' Minimum Required 6.0 7.7 6.1 7.0 8.7 7.1 11.0 12.7 11.1 Installation 158 196 155 178 221 180 279 323 282 Space Hose Clearance Chart Low-Profile Long Elbow Long Elbow Short Elbow V2707 V3802 V2709 V3802 V3802 3/4!'120mm 1/2 113mm 3/4°I2Omm 1/2 113mm 1/2 113mm Max Recess Max Recess Sidewall Max Recess Max Recess inches inches inches inches inches mm mm mm mm mm "R" Minimum - Bend Radius "A" Minimum Required 3.5 4.9 3.6 2.9 3.3 Installation 89 124 91 74 84 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 0 2021 Victaulic Company. All rights reserved. victaulic.com 13 jtIGIUIiC 2' x 4" metal stud 4.8 DIMENSIONS Clearances Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) 21/8160 mm 211/16768 mm I '- Bracket Assembly 2'/Sl mm 2/r'/60 mm min. hole min. hole A cp StyleABil 76 mm See Chart max, hole max. hole 1.7'/4mm 1 Finished Tylp cal 1/87159 mm ceiling ceiling grid Typical See Note 24'7610mm0r fac ceiling tile V27 V38 4871219 mrn on center Pendent Hose Clearance Chart Low-Profile Low-Profile Long Elbow Short Elbow V2707 V3802 3/4 120mm 1/2'113mm Max Recess Max Recess inches inches mm mm "A" Minimum Required 4.0 3.9 Installation 102 99 Space NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 14 '!1jtauIiC I I I victaulic.com 4.9 DIMENSIONS Suspended Ceiling Grid with Recessed Sprinkler and Straight 5.751140mm Reducer Clearances Style AB12 and ABBA Bracket Suspended Ceiling Grid with Recessed Sprinkler with Low Profile Short Elbow 56 mm 28/ 100 mm mm * Adjustability will be limited Style ABMM Bracket Stand-off Dimensions 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. viCtaulic.com 15 '%#tauIic See Low Profile Low Profile I Standard Standard Standard Dimension Short Elbow Long Elbow Short Elbow Long Elbow Straight Reducer 3/4"I19mm 3/4719 MM 3/4'719 MM 3/4719 MM 31419 MM Recessed* Concealed Recessed Concealed Recessed Concealed Recessed Concealed Recessed Concealed inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm I mm mm Minimum Required 4.0 5.5 5.6 7.2 5.9 7.5 7.7 9.3 15.0 16.6 A Installation Space 101.6 139.7 1 142.2 182.9 - 149.9 190.5 195.6 236.2 381.0 421.6 Distance from Top of 05 20 15 15 15 15 30 30 30 30 B Typical Ceiling Tile to 12.7 50.8 38.1 38.1 38.1 38.1 76.2 76.2 76.2 76.2 Bottom of Gate I 1 I I I I I LI I U I I I I I I Typical CeSing V2707 ½/12.7 nrn MAX. RECESS ypical (elllng V2707 W119 n,,n MAX. RECESS t2vrnn I .!.' NoniraI S 14/355.S 4.10 DIMENSIONS Clearances Style AB3 and ABMM Bracket Surface Mount Application with Recessed Sprinkler 2/51 mm mm. hole Hose Clearances inches inches inches inches inches inches inches inches inches inches Dimension mm mm mm mm mm mm mm mm I mm mm Walllhickness 2 4 6 8 10 2 4 6 8 10 50 100 150 200 250 50 100 150 200 250 Outlet Length 5.75 9 13 5.75 9 ri3 9 13 13 13 5.75 5.75f 91 13 9 T 13 13 13 146.1 228.6 330.2 146.1 228.6 330.2 228.6 330.2 330.2 330.2 146.1 228.6 146.1 228.6 330.2 2j330.2 330.2 330.2 HoseClearance 11.6 14.8 18.8 9.6 12.8 16.8 10.8 14.8 12.8 10.8 12.6 [E 15.8 10.6113.8 17.8 11.8 15.8 13.8 11.8 294 376 478 243 325 427 275 376 325 275 319 402 268[351 452 300 402 351 300 Bend Radius 7 8 - 175 - 200 NOTE Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 16 \4'tauIic. art Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Mm. 9.4 10.4 11.4 12.4 13.4 238 263 289 314 339 Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Mm. 7.7 8.7 9.7 10.7 11.7 197 222 247 273 298 I LI I I I I I I I [H I I 4.11 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet I I I I I I I 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 17 '\JtauIic 4.12 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet Tl Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Mm. 9.4 10.4 11.4 12.4 13.41 239 264 290 315 341 Hose Clearance Chart Dimension inches inches inches inches inches mm mm mm mm mm R Minimum 3 4 5 6 7 Bend Radius 80 100 125 150 175 A Mm. 8.1 9.1 10.1 1.1 728117 12.1 205 231 256 307 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victauliC.Com 18 Ai C- -ta - I uirfiilir rnm 5.0 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.757140 mm Reducers USTED Style AB2, AB4, AB5 and AB10 Brackets Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1/33.7mm Sch. 40 pipe inches inches feet mm Type DN meters Max Bends 31 . Straight ½ 15.0 790 DN15 4.6 - - 31 Straight ½ 16.0 790 DN15 4.9 31 Straight 3/4 19.0 790 DN20 5.8 31 Straight 1/4 20.0 790 DN20 6.1 36 Straight ½ 18.0 915 . DN15 5.5 36 Straight 1/2 21.0 915 DN15 6.4 36 . Straight 3/4 21.0 915 -- DN20 6.4 _. 36 . Straight 3/4 23.0 --915 DN20 7.0 48 . Straight ½ 21.0 1220 DN15 ..6.4 48 Straight ½ 32.0 8 1220 DN15 9.8 48 Straight - 3/4 26.0 - -. 1220 DN20 7.9 48 . Straight 3/4 37.0 8 1220 DN20 11.3 60 Straight ½ 27.0 1525 DN15 8.2 60 Straight ½ 46.0 10 1525 DN15 14.0 60 Straight 3/4 27.0 1525 DN20 8.2 60 Straight 3/4 46.0 10 1525 DN20 14.0 72 Straight ½ 31.0 1830 DN15 9.4 72 Straight ½ 55.0 12 1830 DN15 16.8 72 Straight - 3/4 30.0 1830 DN20 9.1 - 72 Straight 3/4 60.0 12 1830 DN20 18.3 I I I I I s 10.855839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 19 Ai-c--t:aul-icr I I I I [Ti I I I I IT I I I victaulic .com 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hose with 90° Low Profile Elbows LISTED Style AB11 VicF!ex Bracket Hose Reducer UL Equivalent Length of Length Nominal Outlet Size 1/33.7mm Sch. 40 pipe inches inches feet mm Type DN meters Max Bends 31 LP Elbow ½ 18.0 3 790 - - -. DN15 5.5 31 LP Elbow ½ 24.0 790 DN15 7.3 31 LP Elbow 3/4 21.0 790 DN20 6.4 31 LP Elbow 3/4 24.0 790 DN20 7.3 36 LP Elbow ½ 19.0 915 DN15 5.8 36 LP Elbow ½ 26.0 915 DN15 79 36 LP Elbow 3/4 23.0 915 DN20 7.0 36 LP Elbow 3/4 28.0 915 DN20 8.5 48 LP Elbow ½ 23.0 1220_ DN15 7.0 48 LP Elbow ½ 43.0 8 1220 DN15 13.1 48 LP Elbow ~ 30.0 1220 - DN20 9.1 48 LP Elbow 3/4 42.0 8 1220 DN20 12.8 60 LP Elbow ½ - 28.0 - 1525 DN15 8.5 60 LP Elbow ½ 49.0 10 1525 DN1S 14.9 60 LP Elbow 3/4 31.0 1525 DN20 9.4 60 LP Elbow 3/4 50.0 10 1525 DN20 15.2 72 - LP Elbow ½ 31.0 1830 . DN15 9.4 72 LP Elbow ½ 65.0 12 1830 DN15 19.8 72 LP Elbow - 3/4 36.0 - 1830 DN20 11.0 - 72 LP Elbow 3/4 63.0 12 1830 DN20 19.2 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 20 J$ttGIUIiC victaulic.com 5.0 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2/51 mm center line bend radius Nominal Outlet 1 2 3 4 5 6 7 8 9 10 11 12 Length Size Bend Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends Bends inches inches feet feet feet feet feet feet feet feet feet feet feet feet mm DN meters meters meters meters meters meters meters meters meters meters meters meters 31 1/2 11.0 13.0 15.0 16.0 790 DN15 3.4 1 4.0 4.6 1 4.9 - - - - - - - - 31 3/4 12.0 14.0 19.0 20.0 790 1 DN20 3.7 4.3 5.8 6.1 - - - - - - 36 ½ 14.0 16.0 18.0 19.0 21.0 915 DN15 4.3 4.9 5.5 5.8 6.4 11 - - - - - - 36 3/4 17.0 19.0 21.0 22.0 23.0 915 DN20 5.2 5.8 6.4 6.7 7.0 - - - - - - 48 1/2 18.0 19.0 21.0 23.0 25.0 27.0 30.0 32.0 1220 DN15 5.5 5.8 6.4 1 7.0 -7.6 1 8.2 9.1 9.8 - - - 48 1/4 21.0 24.0 26.0 28.0 31.0 33.0 35.0 37.0 1220 DN20 6.4 7.3 7.9 8.5 9.4 10.1 10.7 11.3 - - - - 60 ½ 21.0 24.0 27.0 30.0 32.0 35.0 37.0 40.0 43.0 46.0 1525 1 DN15 6.4 7.3 8.2 9.1 9.8 10.7 11.3 12.2 13.1 14.0 - - 60 3/4 23.0 25.0 27.0 29.0 32.0 34.0 37.0 40.0 43.0 46.0 1525 DN20 7.0 1 7.6 8.2 8.8 9.8 10.4 11.3 12.2 13.1 14.0 - 72 1/2 27.0 29.0 31.0 34.0 37.0 40.0 43.0 46.0 48.0 50.0 52.0 55.0 1830 DN15 8.2 8.8 9.4 10.4 11.3 12.2 13.1 14.0 14.6 15.2 15.8 16.8 72 3/4 26.0 28.0 30.0 33.0 37.0 40.0 44.0 48.0 51.0 54.0 57.0 60.0 1830 DN20 7.9 8.5 9.1 10.1 11.3 12.2 13.4 1 14.6 15.5 16.5 17.4 1 18.3 NOTES: Values for use with 5.75?140mm straight reducers. The values in this table are provided by the manufacturer for reference only. For friction loss data in accordance with the UL Certification, please refer to pages 19 and 20 of this publication. How to use this Design Guide: For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. H H I I I I I 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. I victaulic.com 21 'jtauIic Li U I I I I I I I I I 5.1 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, A135, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1/33.7mm at 7/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 1/2 13.8 15 .2 31 5.6 Straight 790 8.1 2 ½ 15 235 90 Elbow 71 1/2 16.6 15 5.1 36 5.6 Straight 915 8.1 2 ½ 15 256 90 Elbow 78 ½ 24 15 7.1 48 5.6 Straight 1220 8.1 ½ 15 307 90 Elbow 9. 1/2 30.2 15 9.2 60 5.6 Straight 1525 8.1 ½ 15 359 90 Elbow 10:9 1/2 15 37.0 72 5.6 Straight 11.3 1830 8.1 ½ 15 41.1 90 Elbow 12.5 16.8 20 5.1 31 8.0 Straight 790 11.5 2 3/4 20 68 90 Elbow 5.1 3/4 20 20 6.0 36 8.0 Straight 915 11.5 2 3/4 20 19.7 90 Elbow 6.0 3/4 20 27.8 48 8.0 Straight 8.4 1220 11.5 ~ 20 26.6 90 Elbow 8.1 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 22 tauIic I I \,Lt -au lic 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 23 victaulic.com p 5.1 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, A135, AB7, AB7 Adj., A138, AB10, AB12, ABBA and ABMM VicF!ex Brackets Maximum Equivalent Number Length of Length of of 90 Bends Stainless Steel Outlet 1'/33.7mm at 7/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 35.7 20 10.9 60 8.0 Straight 1525 11.5 3/4 336 20 10.2 90 Elbow 1/4 43.5 20 13.2 72 8.0 Straight 1830 11.5 3/4 20 406 90 Elbow 12:2 3/4 16.5 20 5.0 31 11.2 Straight 790 16.1 2 3/4 20 178 90 Elbow 5.4 1/4 19.5 20 36 11.2 Straight 915 16.1 2 ~ 20 207 90 Elbow 6.3 3/4 26.7 20 8. 1 48 11.2 Straight 1220 16.1 3/4 20 279 90 Elbow 8.5 33.9 20 10.3 60 11.2 Straight ~ 1525 16.1 20 35 90 Elbow 10.7 20 125 72 11.2 Straight . 1830 16.1 3/4 20 422 90 Elbow 12:8 3/4 14.9 20 .5 31 14.0 Straight 790 20.2 2 3/4 20 155 90 Elbow 4.72 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30 bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. I I I I I I I I I U I I I I I I I victaulic.com 5.1 PERFORMANCE - FRICTION LOSS DATA (CONTINUED) FM Series AH2 and AH2-CC Braided Hoses Style AB2, AB3, AB4, A135, AB7, AB7 Adj., AB8, AB10, AB12, ABBA and ABMM VicFlex Brackets Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1733.7mm at 77178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches inches Imperial mm feet mm S.I. type meters 3/4 19.4 20 5.9 36 14.0 Straight 915 20.2 2 3/4 20 19.6 90* Elbow 5.9 3/4 30.3 20 48 14.0 Straight 9.2 1220 20.2 3 3/4 20 29.5 90, Elbow 8.9 3/4 33.9 20 60 14.0 Straight 10.3 1525 20.2 4 3/4 20 34.1 90' Elbow 10.4 3/4 37.5 20 72 14.0 Straight 11.4 1830 20.2 4 3/4 20 38.6 90' Elbow 11.7 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characteristics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 2400, which is less than the allowable 270°. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 24 'jtauIicr victaulic.com 5.2 PERFORMANCE -FRICTION LOSS DATA Series AH2 Braided Hose with 900 Low Profile Elbows Style AB5, AB11, AB12, ABBA and ABMM VicFlex Bracket Maximum Equivalent Number Length of Length of of 900 Bends Stainless Steel Outlet 1"I33.7mm at 7/178mm Flexible Hose K-Factor Size Sch. 40 Pipe Bend Radius inches Imperial inches feet mm S.I. mm meters 31 5.6 ½ 13.7 790 8.1 15 4.2 2 36 5.6 ½ 17.0 915 8.1 15 5.2 2 48 5.6 ½ 25.0 1220 8.1 15 7,6 60 5.6 ½ 33.0 1525 8.1 15 10.1 72 5.6 ½ 41.1 1830 - 8.1 15 12.5 31 8.0 3/4 13.6 790 11.5 20 4.14 2 36 8.0 3/4 16.9 - 915 - 11.5 20 5.2 2 48 8.0 3/4 27.8 1220 11.5 20 8.5 60 8.0 3/4 32.6 1525 11.5 20 9.9 72 8.0 3/4 40.6 1830 11.5 20 12.4 31 11.2 3/4 13.7 790 16.1 20 4.2 ..- 2 36 11.2 3/4 17.0 915 16.1 20 5.2 2 48 11.2 3/4 24.9 _1220 16.1 20 7.6 60 11.2 ~ 32.9 1525 - 16.1 20 10.0 4 72 11.2 ~ .40.9 1830 - 16.1 20 12.5 4 31 14.0 3/4 13.5 2 790 20.2 20 4.1 36 14.0 3/4 16.8 2 915 20.2 20 5.1 48 14.0 ~ 24.7 3 1220 20.2 20 7.5 60 14.0 ~ 32.7 4 1525 20.2 20 9.9 72 14.0 ~ 40.7 1830 20.2 20 12.4 FM NOTES: The Series AH2 hose has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 130 and FM data sheets 2-0, 2-5, and 2-8. FM 1637 standard for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. EXAMPLE: A 48-inch hose installed with two 300 bends and two 900 bends is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. U I I 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company, All rights reserved. victaulic.com 25 \j#t -au Iic U I U I U LI I U I LI I I U victaulic.com 5.3 PERFORMANCE - FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hose Style AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB10, AB11 and AB12 Brackets Equivalent Length of Length of steel pipe according to Stainless Steel Outlet EN 10255 DN 25 Maximum Number Flexible Hose Size (33,7 x 3,25) of 90" Bends at mm DN meters 3°/76.2mm Bend inches inches feet Radius DN1S 790 ½ 5.5 3 DN20 31 18.0 3/4 DN15 915 ½ 6.4 3 DN20 36 21.0 3/4 DN1 5 1220 ½ 8.5 48 27.9 3 DN20 3/4 DN1 5 1525 1/2 10.7 60 35.1 4 DN20 3/4 DN1 5 1830 ½ 1 12.8 72 42.0 4 DN20 3/4 VdS Ceiling Manufacturers List AB2, AB7, AB10 ,AB11 AB4 AB5, AB8 1. AMF No specific approval 1. Hilti 2. Armstrong Knauf Chicago Metallic 3. Lafarge 4. Dipling 4. Lindner 5. Durlum 5. Rigips 6.Geipel Gema-Armstrong Hilti Knauf Lafarge Linder Odenwald Richter Rigips Rockfon Pagos Suckow & Fischer USG Donn 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 26 %Ai 1tauIic 5.3 PERFORMANCE - FRICTION LOSS DATA OLPCB Series AH2 and AH2-CC Braided Hose Style AB2, AB3, AB4, AB5, AB7, AB8, and AB10 Brackets Length of Equivalent Length Maximum Stainless of steel pipe Number of Steel according to 90" Bends at Flexible Outlet EN 10255 DN 25 3776.2mm Hose Size (33,7 x 3,25) Bend Radius mm mm inches meters inches type feet 15 mm ½ 790 Straight 1.8 31 6.0 2 20mm 3/4 Straight 15 mm ½ 915 Straight 3.6 36 11.9 20mm 3/4 Straight 15 mm ½ 1220 Straight 4.3 48 14.0 3 20mm 3/4 Straight 15 mm ½ 1525 Straight 4.1 60 13.6 20mm 3/4 Straight 15 mm ½ 1830 Straight 5.5 72 18.1 3 20mm 3/4 Straight Series AH2 Braided Hose 4 Style AB2, AB3, AB4, AB5, AB7, AB8, AB10 and AB12 Brackets Equivalent Length of Length of 1/33.7mm Sch. 40 Pipe Flexible Hose Straight Configuration Bend Configuration mm meters meters inches feet feet 790 0.87 2.70 31 2.9 8.9 915 1.00 2.80 36 3.3 9.2 1220 2.23 4.66 48 7.3 15.3 1525 2.90 6.5 60 95 21.3 1830 3.31 7.16 72 10.9 23.5 CCCF NOTE Friction loss data is in accordance with GB5135.16 tested at a flow rate of 114 liters per minute (30 gallons per minute). I I I I I I I I I I I LI I I I I I I 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. I victaulic.com 27 \j1tauIic victaulic.com 6.0 NOTIFICATIONS WARNING m Read and understand all instructions before attempting to install any Victaulic products. Always verify that the piping system has been completely depres- surized and drained immediately prior to installation, removal, adjustment, or maintenance of any Victaulic products. Wear safety glasses, hardhat, and foot protection. These products shall be used only in fire protection systems that are designed and installed in accordance with current, applicable National Fire Protection Association (NFPA 13, 13D, 13R, etc.) standards, or equivalent standards, and in accordance with applicable building and fire codes. These standards and codes contain im- portant information regarding protection of systems from freezing temperatures, corrosion, mechanical damage, etc. The installer shall understand the use of this product and why it was specified for the particular application. The installer shall understand common industry safety standards and potential consequences of improper product installation. WARNING It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. It is the responsibility of the owner of a building or their authorized agent to provide the sprinkler system installer with any knowledge that the water supply might be contaminated with or conducive to the development of micro- biologically influenced corrosion (MIC), including as required by NFPA 13. Failure to identify adverse water quality issues may affect the VicFlex product and void the manufacturer's warranty. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. Victaulic VicFlex Series AH2 and AH2-CC Flexible Sprinkler Fittings may be painted provided the paint is compatible with stainless steel and zinc-plated carbon steel or ductile iron. Care should be taken to ensure the sprinkler and associated escutcheon or coverplate are not painted. Victaulic VicFlex Series AH2 and AH2-CC penetrating through non-fire rated gypsum wall (drywall) will function as designed, provided the components are installed in accordance with the respective installation instructions referenced in this document. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 28 XAC-ta-ul-icr victaulic.com 7.0 REFERENCE MATERIALS - CHARACTERISTICS VicFlex Maximum Load Values Series AH2 Hose with 24" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linearft N/linearm 31/790 2.6 5.2 23 2.6 38 0.8 36/915 5.5 25 2.8 40 0.9 48/1220 6.3 28 3.1 46 12 60/1525 7.0 31 3.5 51 1.5 72/1830 168 57 Series AH2 Hose with 48" Bracket Actual Length Total Load Max. Uniform Load ft Model Size m lb N lb/linearft N/linearm 31/790 2.6 6.1 27 1.5 22 0.8 36/915 6.4 29 1.6 23 0.9 48/1220 7.2 32 1.8 26 1.2 60/1525 7.9 35 2.0 29 1.5 72/1830 168 8.7 39 2.2 32 Total Load is defined as the sum of the weights of the folloving: water-filled flexible sprinkler hose with threaded end fittings, including a typical fire sprinkler bracket assembly (any applicable Victaulic bracket model of the relevant associated size) ASTM C 635: Suspension System Load-Carrying Capabilities (excerpted) Suspension System Actual Length Wm Mm. Allowable Uniform Load lb/linear ft N/linear m Direct Hung Light Intermediate 5.0 12.0 75.7 181.0 Heavy 16.0 j 241.7 SUMMARY: All direct-hung suspension system duty classifications per ASTM C 635 are able to withstand the maximum water-filled weight of the VicFlex sprinkler hose and bracket. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 29 \Ltaulic virt;klllir rnm 7.0 REFERENCE MATERIALS - CHARACTERISTICS (CONTINUED) Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends 2'X Minimum Minim.. Nad, Mi fib.nd Mini mum raudmu, Mm,mum M" bend,adi.s bend radius bend bend radius OR nimum OR bend radius 0. Minimum bend radius Mum - ' ben dMinimum bend radius bend radius NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. l-vicFlex-AB1-AB2 l-VicFlex-AB3 l-vicFlex-AB4 l-VicFlex-AB5 l-VicFlex-AB7 l-VicFlex-ABI2 1-Vic Flex-A B BA l-VicFlex-ABMM t-RES User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions at sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use at any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms "Patented" or "Patent Pending" refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries, Note This product shall be manufactured by Victaulic arts Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to l-VICFLEX-AB1-AB2-AB10, l-VICFLEX-AB4, l-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in POE format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Vicfaufic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 10.85 5839 Rev AK Updated 03/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 30 Ait aui ic I I I FM Approved and Fully Listed Sprinkler Pipe Wheatland Tube's Schedule 10 and Schedule 40 steel fire sprinkler pipe is FM Approved and UL® and C-UL Listed. I Approvals and Specifications Schedule 10 and Schedule 40 meet or exceed I the following standards: ASTM A135, Type E, Grade A (Schedule 10, 1-8 NPS) I . ASTM A795, Type E, Grade A (Schedule 40,1-2 NPS) ASTM A53, Type E, Grade B I (Schedule 40, 2-8 NPS) ASTM A53, Type F, Grade A (Schedule 40,1-4 NPS) I NFPA® 13 and NFPA 14 Manufacturing Protocols I Schedule 10 and Schedule 40 are subjected to the toughest possible testing protocols to ensure the highest quality and long-lasting performance. I I I Finishes and Coatings All Wheatland black steel fire sprinkler pipe receives a proprietary mill coating to ensure a clean, corrosion-resistant surface that outperforms and outlasts standard lacquer coatings. This coating allows the pipe to be easily painted, without special preparation. Schedule 10 and Schedule 40 can be ordered in black or hot-dip galvanized, to meet FM/UL requirements for dry systems that meet the zinc coating specifications of ASTM A795 or A53. Product Marking Each length of Wheatland fire sprinkler pipe is continuously stenciled to show the manufacturer, type of pipe, grade, size and length. Bar coding is acceptable as a supplementary identification method. PROJECT: CONTRACTOR: DATE: I ENGINEER: SPECIFICATION REFERENCE: SYSTEM TYPE: I LOCATIONS: COMMENTS: D BLACK 1 Council Avenue, P.O. Box 608 info@wheatland.com Wheatland . PA 16161 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 @Wheatlandrube HOT-DIP GALVANIZED t V eatard Tube A DIVISION OF ZEKELMAN INDUSTRIES I LI 1 Council Avenue, P.O. Box 608 info@wheatland.com - Wheatland, PA 16161 wheatland.com P 800.257.8182 Follow us on Twitter: F 724.346.7260 @Wheatlandlube tWheatIard Tube A DIVISION OFZEKLMAN INDUSTRIES SCHEDULE 10 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINALWALL WT./FT. H5OFILLED PCS./LIFT 21 24 25 UL 1 II mm IL lnJ[m_J[ In. mm lbs. lbs. ir 1L_.]L]I lbs. CRR 1 1.315 33.4 1.097 27.9 0.109 2.77 1.405 1.814 70 2065 2360 2459 11.4 - __•i -. 1'/4 1 660 422 1442 366 JL 0109 277 1 807 2 514 61 2315 2645 I 2756 73 - L 11/2 1.900 48.3 1.682 42.7 0.109 2.77 2.087 3.049 61 2673 3055 3183 5.8 • 2 .• 2.375 60.3 2.157 ,. 54.8 ---1 . 0.109 .. H 2.77 H 2.640 4.222 .. 37 2051 2344 2442 4.7 • . - .. .......... - . . . ..... 2% 2.875 73.0 2.635 66.9 0.120 3.05 3.354 5.895 30 2226 2544 2651 3.5 3 3.500 889 3.260 82.8 0.120 L 305 4.336 7.949 19 1 1730 1977 11 2060 26 - 4 4.500 114.3 4.260 108.2 0.120 3.05 5.619 11.789 19 2242 2562 2669 1.6 5 i 5.563 141.3 5.295 - - 'F 134 5 0134 340 7.780 17.309 - 13 2124 - 2427 2529 I .5 .1 -- 6 6.625 168.3 6.357 161.5 0.134 3.40 9.298 23.038 10 1953 2232 2325 1.0 ..------ 8 8.625 2191 8.249 1 2095 0.188 478 1 16.960 40.086 7 2493 2849 2968 21 L SCHEDULE 40 WEIGHTS AND DIMENSIONS WT./FT. WT./LIFT WT./LIFT WT./LIFT NPS NOMINAL OD NOMINAL ID NOMINAL WALL WT./FT. H20 FILLED PCS./LIFT 21 24 25 UL in. mm IL in. mm in. I[ mm lbs. lb,. lbs. lbs. j lbs. CRR 1 1.315 33.4 1.049 26.6 0.133 3.38 1.68 2.055 70 2470 2822 2940 1.000 1¼ 1.660 422 1.380 351 1 0.140 356 227 2.922 51 2431 2778 1 2894 1.000 11/2 1.900 48.3 1.610 40.9 0.145 3.68 2.72 3.602 44 2513 2872 2992 1.000 2 2.375 60.3 2.067 52.5 0.154 3.91 366 5109 24 1845 2108 r 2196 1.000 L - 21/2 2.875 73.0 2.469 62.7 0.203 5.16 5.80 7.871 20 2436 2784 2900 1.000 - 3 I .. 3.500 88.9 3.068 ,. . . 77.9 '. ----------------------------------------., -'fl H 0.216 - - 4. 5.49 - - JL 7.58 - 10.783 -- ... 13 .. 2069 . ... 2365 1 - .L 2464 - .. 1.000 ------ 31/2 4.000 101.6 3.548 90.1 0.226 5.74 9.12 13.400 10 1915 2189 2280 1.000 n-- .- 4 4.500 114.3 4.026 102.3 I 0.237602 1080 16.311 10 2268 2592 2700 1.000 5 5.563 141.3 5.047 158.2 0.258 6.55 14.63 23.262 7 2151 2458 2560 1.000 6 6.625 1683 6.065 1541 0.280 711 1899 31.498 5 1994 2279 2374 1.000 8" 8.625 219.1 7.981 202.7 0.322 8.18 28.58 50.240 5 3001 3430 3573 1.000 Calculated using Standard UL CRR formula, UL Fire Protection Directory. Category VIZY The CRR is a ratio value used to measure the ability of a pipe to withstand corrosion. Threaded Schedule 40 steel pipe is used as the benchmark (value of 1.0). 8 NPS Schedule 40 is FM Approved but not UL Listed. (9 C(E) APPROVED W15-060520 I I I r SCI Prol%&Eff System Ductile Iron Threaded Fittings Specifications <j> branded fittings are UL Listed and FM Approved at 500 psi Rated to 300 psi WSP U c®Lus Ductile iron castings conform to ASTM A536 USTED Fitting dimensions conform to ASME B16.3 Bushings and plugs conform to ASME B16.14 All fittings are 100% air tested APPROVED NPT threads on all fittings conform to ASME B1.20.1 Independent lab verification that fittings meet applicable chemical & mechanical properties Manufacturing facilities are ISO 9001:2008 and ISO 14001 ProPakTM Packaging Temperature Degrees F Working Pressure, Non-Shock psig Class 300 Threaded Fillings -20 to 100 500 150 500 200 480 250 460 - 300 440 350 420 400 400 450 380 500 360 550 340 600 320 650 300 1 Fig. 35E 3_900 Elbow C@US APPROVED LISTED in I Size I Part Number A in Packing Weight lb Inner Master I 1/2 35E 3004 1.13 100 200 0.2 I 35E 3006 1.31 70 140 0.3 I 1 35E 3010 1.50 40 80 0.5 1 1-1/4 35E3012 1.75 25 50 0.8 F 1-1/2 35E3014 1.94 18 36 1.1 2 35E3020 2,25 10 1 20 1.8 1 2-1/2 35E3024 2.70 4 1 8 3.2 Fig. 35RE3 - 900 Reducing Elbow Size in Part Number A in B in Packing Weight lb Inner Master 3/4x 1/2 35RE3006004 1.20 1.22 80 160 0.3 1 x 1/2 35RE3010004 1.26 1.36 70 140 0.4 1 x3/4 35RE3010006 1.38 1.45 50 100 0.4 1-1/4x 1/2 35RE3012004 1.34 1.53 35 70 0.5 1-1/4x3/4 35RE3012006 1.45 1.63 35 70 0.6 1-1/4x 1 35RE3012010 1.58 1.67 30 60 0.7 1-1/2x 1/2 35RE3014004 1.52 1.75 30 60 0.6 1-1/2x 3/4 35RE3014006 1.52 1.75 25 50 0.7 1-1/2 x 1 35RE3014010 1.65 1.80 20 40 0.8 1-1/2 x 1-1/4 35RE3014012 1.82 1.88 18 36 1.0 2 x 1/2 35RE3020004 1.60 1.97 18 36 1.0 2 x 3/4 - 35RE3020006 . .60 1.97 18 36 10 2 x 1 35RE3020010 1.73 2.02 16 32 1.2 2x1-1/4 35RE3020012 , 1.90 2.10 1.2 24 1.3 2 x 1-1/2 35RE3020014 2.02 2.16 10 20 1.5 2-1J2x 1-1/2 35RE3024014 2.16 2.51 6 12 . 2.2 2-1/2 x 2 35RE3024020 2.39 2.60 6 12 2.5 Size in Part Number A in Packing Weight lb Inner Master I_1/2 35F 3004 0.88 150 300 0.2 L314 35F 3006 0.98 80 160 0.3 I_1 35F3010 1.13 40 80 0.5 1-1/4 35F3012 1.29 25 50 0.7 F_1-1/2 35F 3014 1.44 20 40 1.0 2 35F 3020 , 1.69 , 10 20 1.6 - 1_2-1/2 35F3024 1.95 4 8 2.7 Fig.35T 3- Tee Size in Part Number A in Packing Weight lb Inner Master 1/2 3513004 1.13 80 160 0.3 3/4 35T3006 1.31 30 60 0.5 1 35T3010 1.50 25 50 0.7 1-1/4 3513012 1.75 10 20 1.1 1-1/2 35T 3014 1.94 10 20 1.5 2 35T 3020 , 2.25 6 12 2.4 2-1/2 35T3024 2.70 4 8 4.3 I 237 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com I I I I I I I I Size in Part Number A in B in C in Packing Weight lb Inner Master 3/4x1 35B13006010 1.45 1.45 1.37 30 60 0.6 1x1-1/4 35B13010012 1.67 1.67 1.58 20 40 0.9 '1x1-1/2 35BT3010014 1.80 1.80 1.65 15 30 1.0 1-1/4x1x1-112 35813012010014 1.88 1.80 1.82 15 30 1.2 1-1/4x1-1/2 35BT3012014 1.88 1.88 1.82 15 30 1.3 1-1/4x2 35BT3012020 :2J.0. 2.10 1.90 . 10 20 . 1.6 1-1/2x1-1/4x2 35813014012020 2.16 2.10 2.02 10 20 1.8 1-1/2x2 .35BT3014020 2.16 2.16 2.02 8 16 1.8 ii C®uS LISTED APPROVED Fig. 35RT3 - Reducing Tee Size in Pad Number A in B in C in Packg_ Weight lb Inner Master 3/4x 1/2 35RT3006004 1.20 1.20 1.22 60 120 0.4 1x1/2 35RT3010004 1.26 1.26 1.36 30 60 0.6 1x1/2x1 35R13010004010 1.50 1.36 1.50 30 60 0.6 1x3/4 35RT3010006 1.38 1.38 1.45 25 50 0.6 1x3/4x3/4 35RT3010006006 1.38 1.31 1.45 35 70 0.6 1x3/4x1 35RT3010006010 1.50 1.45 1.50 25 50 0.7 1-1/4x1/2 35RT3012004 1.34 1.34 1.53 20 40 0.8 1-1/4x1/2x1-1/4 35RT3012004012 1.75 1.53 1.75 25 50 0.9 1-1/4x3/4 35R13012006 1.45 1.45 1.62 15 30 0.9 1-1/4x3/4x 1-1/4 35RT3012006012 1.75 1.62 1.75 20 40 1.0 1-1/4x1 35RT3012010 1.58 1.58 1.67 15 30 1.0 1-1/4x1x1/2 35RT3012010004 1.34 1.26 1.53 25 50 0.7 1-1/4x 1 x3/4 35RT3012010006 1.45 1.38 1.63 20 40 0.8 1-1/4 x1x1 35RT3012010010 1.58 1.50 1.69 20 40 0.9 1-1/4x1x1-1/4 35R13012010012 1.75 1.69 1.75 15 30 1.0 1-1/2x1/2 35RT3014004 1.41 1.41 1.66 16 32 1.0 1-1/2x1/2x1-1/4 35RT3014004012 1.81 1.56 1.88 24 48 1.1 1-1/2x1/2x1-1/2 35R13014004014 1.94 -1.66 1.94 12 24 1.2 1-1/2x3/4 358T3014006 1.52 1.52 1.75 16 32 1.1 1-1/2x3/4x1-1/4 35RT3014006012 1.94 1.66 1.88 20 40 1.1 1-1/2x3/4x1-1/2 35R13014006014 1.94 1.75 1.94 18 36 1.2 1-1/2x1 358T3014010 1.65 1.65 1.80 12 24 1.2 1-1/2x1x1/2 35RT3014010004 1.44 1.25 1.69 20 40 0.8 1-1/2x1x 3/4 35RT3014010006 1.50 1.44 1.75 16 32 . 0.9 1-1/2x1xl 35RT3014010010 1.65 1.50 1.80 16 32 1.0 1-1/2x1x1-1/4 35RT3014010012 1.82 1.67 , 1.88 12 24 1.2 1-1/2x1x1-1/2 35RT3014010014 1.94 1.80 1.94 12 24 1.3 1-1/2x1-1/4 35R13014012 1.82 1.82 1.88 12 24 1.4 1-1/2x1-1/4x1/2 35RT3014012004 1.41 1.34 1.66 16' 32 0.9 1-1/2x1-1/4x3/4 35RT3014012006 1.52 1.45 1.75 16 32 1.0 1-1/2x1-1/4x1 35RT3014012010 1.65 1.58 1.80 16 32 1.1 1-1/2x1-1/4x1-1/4 35RT3014012012 1.82 1.75 1.88 14 28 1.3 1-1/2x1-1/4x1-1/2 35RT3014012014 1.94 1.88 1.94 14 28 1.4 2x112 35RT3020004 1.49 1.49 1.88 10 20 1.5 2x3/4 35RT3020006 1.60 1.60 1.97 10 20 1.6 2x1 35RT3020010 1.73 1.73 2.02 8 16 1.7 2 x 1 x 2 35RT3020010020 2.25 2.02 2.25 8 16 1.9 2x1-1/4 35RT3020012 1.90 1.90 2.10 =8= 16 1.9 2x1-1/4x2 35RT3020012020 2.25 2.10 2.25 8 16 2.0 2x1-1/2 35RT3020014 . 2.02 2.02 2.16 8 16 2.1 2x1-1/2x1/2 35RT3020014004 1.49 1.41 1.88 10 20 1.3 2x1-1/2x3/4 35R13020014006 1.60 1.52 1.97 10 20 1.4 2x1-1/2x1 35RT3020014010 1.73 1.65 2.02 8 16 1.5 2x1-1/2x1-1/4 35RT3020014012 1.90 1.82 2.10 8 16 1.7 2x1-1/2x1-1/2 358T3020014014 2.02 1.94 2.16 8 16 1.8 Fig. 35BT3 - Bull Head Tee SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com 238 I Size in Part Number A in Packing Weight lb Inner Master 1/2 35CP3004 1.38 200 400 0.1 3/4 35CP3006 1.63 100 200 0.2 1 35CP3010 1.75 60 120 0.4 1-1/4 35CP3012 2.00 35 70 0.5 1-1/2 35CP3014 2.19 25 50 0.7 2 35CP3020 2.62 15 30 1.2 2-1/2 350P3024 3.00 9 18 2.2 Fig. 35RC3 - Hex Reducing Coupling in I Size I Part Number A in Packing Weight lb Inner Master 1 x 1/2 35R03010004 1.69 80 160 0.3 1 x3/4 35RC3010006 1.69 60 120 -. 0.4 I 1-1/4 x 3/4 35R03012006 2.06 40 80 0.6 i2 x 1 (not hex) I 35RC3020010 2.81 20 40 1.0 Fig. 35HB3 -Hex Bushing Size in Part Number A in B in Packing Weight lb Inner Master 1x1/2 35H83010004 1.06 1.40 180 360 0.2 1x3/4 35HB3010006 1,06 _1Q_ 180 360 0.1 1-1/4 x1 35HB3012010 1.19 1.80 90 180 0.2 1-1/2x1 35HB3014010 1.25 1.95 75 150 0.4 1-1/2x1-1/4 35HB3014012 1.25 1.95 75 150 0.3 2 x 1 35HB3020010 1,38 2.55 40 80 0.6 2x1-1/4 35HB3020012 1.38 2.55 40 80 0.6 2x1-1/2 35HB3020014 1.38 2.55 40 80 0.6 I F9f I I I 1 Fig. 355P3 - Square Head Plug Size in Part Number A in Packing Weight lb Inner I Master 1/2 35SP3004 0.94 600 1200 0.07 3/4 35SP3006 1.12 . 350 700 . 0.1 1 35SP3010 1.25 200 400 0.1 1-1/4 35SP3012 1.37 100 200 0.3 1-1/2 35SP3014 1.44 80 160 0.4 2 35SP3020 1.50 45 90 0.6 Elks I I I Fig. 35U 3- Union with Brass Seat Size in Part Number _______________ A in Packing Weight lb Inner Master 1 35U3010 2.19 20 40 1.0 1-1/4 35U3012 2.50 15 30 1.2 1-1/2 35U3014 2.62 10 20 1.7 2 35U3020 3.12 6 12 2.4 I I I I 1 I Fig. 35CP3 - Straight Coupling with Ribs c®uS <E> APPROVED LISTED 239 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 • www.smithcooper.com I c@ us APPROVED Fig. 35X 3- Cross LISTED Size in Part Number A in Packing Weight lb Inner Master 1 35X3010 1.50 20 40 0.9 1-1/4 35X3012 1.75 12 24 1.4 1-1/2 35X3014 1.94 8 16 1.8 2 35X 3020 1 2.25 1 6 12 2.8 A A A A Fig. 35R13 - Reducing Cross I Size I in I Part Number I A in I B Iin I Packing I Weight I lb Inner I Master 1-1/4x1 I 35RX3012010 I 1.67 1.58 I 15 30 I 1.2 1-1/2x1 I 35RX3014010 I 1.80 I 1.65 I 12 1 24 1 1.4 2x1j 35RX3020010 2.02 1.73 8 r 16 2.0 Fig. 35C 3- Cap Size in Part Number A in Packing Weight I lb I Inner Master 1/2 35C 3004 0.87 300 600 0.1 I 3/4 35C 3006 0.97 200 400 0.1 1 1 3503010 1.16 110 220 0.2 1-1/4 35C 3012 1.28 70 140 0.4 1 1-1/2 35C 3014 1.33 50 100 0.5 1 2 35C 3020 1.45 25 50 0.8 I 2-1/2 35C 3024 1.70 18 36 1.6 -1 Fig. 35RC3 - Ream Clamp Size in Part Number A in Packing I Weight I lb Inner I Master 3/8 35B03003 0.75 100 200 0.3 1/2 35B03004 0.75 80 160 .0.5 SMITH-COOPER INTERNATIONAL® • TOLL FREE 1-800-766-0076 • FAX (323) 890-4456 0 www.smithcooper.com 240 Victaulic® FireLockTM Outlet-I A-i-r--taull-cr Style 922 10.52 1.0 PRODUCT DESCRIPTION Available Sizes 11/4 _2½"/DN32_DN65 Threaded Outlet Sizes: 1/2'/DN15, 3/4 /DN20, and 1/DN25 NOTE IGS Grooved 11DN25 Outlets available for this product. See publication 10.54. Maximum Working Pressure 300p5i/2068kPa/21 Bar Application Provides a convenient method of incorporating outlets for directly connecting sprinklers, drop nipples, sprigs, gauges, drains and other outlet products Pipe Material Carbon steel Contact Victaulic for use on additional pipe types and wall thicknesses 2.0 CERTIFICATION/LISTINGS czsE1 @ LIVID LPS1186 Issue 3.I CO,*/LPCB Ref. 49leI27 NOTES See Section 7.2 REFERENCE MATERIALS for additional certification information. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic company. All rights reserved. taullill 1 a I I I I I I I I I I I I I I I I I I victaulic.com 3.0 SPECIFICATIONS - MATERIAL El Housing: Ductile iron conforming to ASTM A536, Grade 65-45-12. Ductile iron conforming to ASTM A395, Grade LI 65-45-15, is available upon special request. Housing Coating: (specify choice) Orange coating. Red coating (standard for EMEA-I and Asia Pacific). Optional: Contact Victaulic with your requirements for other coatings. Gasket': Grade "E" EPDM (Type A) EPDM (Violet color code) Applicable for wet and dry (oil-free air) sprinkler services only. Listed/Approved for continuous use in wet and dry systems. Listed/Approved for dry systems at -40°F/-40C and above. NOT COMPATIBLE FOR USE WITH HOT WATER SERVICES OR STEAM SERVICES. E l Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Seal Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. Bolts/Nuts: Standard: Carbon steel oval neck track bolts meeting the mechanical property requirements of ASTM A449 (imperial) and ISO 898-1 Class 9.8 (metric). Carbon steel hex flange nuts meeting the mechanical property requirements of ASTM A563 Grade B (imperial - hex nuts) and ASTM A563M Class 9 (metric - hex nuts). Track bolts and hex flange nuts are zinc electroplated per ASTM B633 Fe/Zn 5, finish Type III (imperial) or Type II (metric). 10.52 03355 Rev J updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 2 'Jt _au Iic victaulic.com 4.0 DIMENSIONS Style 922 Style 922 Size Bolt/Nut - Dimensions Weight Nominal Actual Approximate Run x Branch FPT2 Outside Diameter Qty. Size T3 V W V Z (Each) inches inches inches inches inches inches inches inches lb DN mm mm mm mm mm mm mm kg 1¼ 1/2 1.660 0.840 1.30 1.83 1.10 3.87 2.56 1 DN32 X DN15 42.4 X 21.3 2 3/ex13/a 33 47 28 98 65 0.5 1.28 1.83 1.10 3.87 2.56 1 '/4 1.050 DN20 26.9 2 3/ x 11/8 33 47 28 98 65 0.5 1.52 2.18 1.10 3.87 2.56 1 1 1.315 0N25 2 /8 X 1 /e 39 55 28 98 1 65 0.5 11/2 1/2 1.900 0.840 1.42 1.95 1.22 4.08 2.56 1 40 DN15 48.3 21.3 2 3/eX13/e 36 50 31 104 65 0.5 2 1.40 1.95 1.22 4.08 2.56 1 '/4 1.050 DN20 26.9 3/8 X13/8 36 50 31 104 65 0.5 1.64 2.30 1.22 4.08 2.56 1 1 1.315 DN25 2 3/sx 1 /s 42 58 31 104 65 0.6 2 1/2 2.375 0.840 1.66 2.19 1.46 4.60 2.56 1 50 DN15 60.3 21.3 2 3/8 X11/8 42 56 37 117 65 0.6 2 1.64 2.19 1.46 4.60 2.56 1 3/4 1.050 DN20 26.9 /e xl /8 42 56 37 117 65 0.6 1.88 2.54 1.46 4.60 2.56 2 1 1.315 DN25 2 3/ xl 3/ 48 1 65 37 117 65 _0.7 - 21/2 ½ 2.875 0.840 1.91 2.44 1.71 5.40 2.56 2 X DN15 73.0 X 21.3 2 3/exl3/8 49 62 43 137 65 0.7 1.89 2.44 1.71 5.40 2.56 2 3/4 1.050 DN20 26.9 2 3/8X 1/8 48 62 43 137 65 0.7 2.13 2.79 1.71 5.40 2.56 2 1 1.315 DN25 2 %x 1 /8 54 71 43 137 65 0.7 DN65 1/2 3.000 0.840 1.91 2.44 1.71 5.50 2.56 2 DN15 76.1 21.3 2 3/ex13/e 49 62 43 140 65 0.7 1.89 2.44 1.71 5.50 2.56 2 3/4 1.050 DN20 26.9 2 3/x13/a 48 62 43 140 65 0.7 2.13 2.79 j 1.71 5.50 2.56 2 1 1.315 DN25 2 3/sx13/e 54 71 43 140 65 0.8 2 Victaulic female threaded products are designed to accommodate standard NPT or BSPT (optional) male pipe threads only. Refer to the specific literature for these types of special male-threaded products for guidance and possible limitations for use. Failure to verify suitability in advance may result in assembly problems or leakage. Center of run to engaged pipe end for NPT threads (dimensions are approximate). 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 3 Ai-c-taul-icr victaulic.com 5.0 PERFORMANCE Style 922 Equivalent Length of 1 inch Schedule 40 Steel Pipe (per UL 213, Section 16) (C=120)4 Run Size x Outlet Size Threaded Grooved5 inches feet feet DN meters meters 1'/4 1 8.5 12.5 DN32 DN25 2.6 3.8 11/2 1 8.5 12.5 DN40 DN25 2.6 3.8 2 1 8.5 12.5 DN50 DN25 2.6 3.8 21/2 1 8.5 12.5 DN25 2.6 3.8 1 8.5 12.5 DN65 DN25 - 2.6 3.8 Hazen-Williams coefficient of friction is 120. F FireLockrM Innovative Groove System (IGS) outlet 6.0 NOTIFICATIONS WARNING Read and understand all instructions before attempting to install, remove, adjust, or maintain any Victaulic piping products. Depressurize and drain the piping system before attempting to install, remove, adjust, or maintain any Victaulic piping products. Wear safety glasses, hardhat, and foot protection. Failure to follow these instructions could result in death or serious personal injury and property damage. 7.0 REFERENCE MATERIALS Dimensions Minimum Hole Diameter! Maximum Hole Diameter! Hole Saw Size Hole Saw Size inches inches mm mm I All Outlet Sizes 1 3A6 11/4 30 - 32 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. victaulic.com 4 \4tauIic virfiiilir mm 7.1 REFERENCE MATERIALS Size Services Pressures per Regulatory Approvals and Listings6 Nominal UL ULC FM VdS LPCB CNBOP inches psi psi psi psi psi psi DN kPa kPa kPa kPa kPa kPa 1 Y4x½ 300 300 300 232 232 232 DN32XDN15 2068 2068 2068 1600 - 1600 1600 1 1/4XN4 300 300 300 232 232 232 DN32XDN20 2068 2068 2068 1600 1600 1600 1¼x1 300 300 300 232 232 232 DN32XDN25 - 2068 2068 2068 1600 1600 1600 1½x'/2 300 300 300 232 232 232 DN40XDN15 2068 2068 2068 1600 1600 1600 1½x3/4 300 300 300 232 232 232 DN40XDN20 2068 2068 2068 1600 1600 1600 1 '/2x1 300 300 300 232 232 232 DN40XDN25 2068 2068 2068 1600 1600 1600 2x½ - 300 - 300 300 - 232 232 232 DN50XDN15 2068 2068 2068 - 1600 -- 1600 - - 1600 2x1/4 300 300 300 232 232 232 DN50X20 2068 2068 2068 1600 1600 1600 2x1 300 300 300 232 232 232 DN50XDN25 2068 2068 - 2068 1600 1600 1600 2½x½ 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 2½x3,4 300 300 300 232 232 232 2068 2068 2068 1600 1600 - 1600 2½x1 300 300 300 232 232 232 2068 2068 2068 1600 1600 1600 300 232 232 232 DN65XDN15 - 2068 1600 1600 1600 300 232 232 232 DN65XDN20 - - 2068 1600 1600 1600 300 232 232 232 DN65XDN25 - 2068 1600 1600 1600 6 Pressures listed in this chart are based upon standard wall pipe. Approved and Listed pressures may vary by pipe schedule. NOTE Consult regulatory agency websites for details and the most recent regulatory information 7.2 REFERENCE MATERIALS 05.01: Victaulic Seal Selection Guide I 29,01: Victaulic Terms and Conditions of Sale 1-100: Installation Instructions -922: Installation Instructions FireLock°M Outlet-T I S User Responsibility for Product Selection and Suitability Note Each user bears final responsibility for making a determination as to the suitability of This product shall be manufactured by Victaulic or to Victaulic specifications. All products Victaulic products tore particular end-use application, in accordance with industry to be installed in accordance with current Victaulic installation/assembly instructions. standards and project specifications, and the applicable building codes and related Victaulic reserves the right to change product specifications, designs and standard regulations as well as Victaulic performance, maintenance, safety, and warning equipment without notice and without incurring obligations. instructions. Nothing in this or any other document, nor any verbal recommendation, Installation advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, Reference should always be mode to the Victaulic installation handbook or installation or waive any provision of Victaulic Company's standard conditions of sale, installation instructions of the product you are installing. Handbooks are included with each shipment guide, or this disclaimer, of Victaulic products, providing complete installation and assembly data, and are available Intellectual Property Rights in PDF format on WeChat. No statement contained herein concerning a possible or suggested use of any material, warranty product, service, or design is intended, or should be constructed, to grant any license Refer to the Warranty section of the current Price List or contact Victaulic for details. under any patent or other intellectual property right of Victaulic or any of its subsidiaries or affiliates covering such use or design, or as a recommendation for the use of such Trademarks material, product, service, or design in the infringement of any patent or other intellectual Victau/ic and all other Victaulic marks are the trademarks or registered trademarks of property right. The terms "Patented" or "Patent Pending" refer to design or utility patents Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. on patent applications for articles and/or methods of use is the United States and/or other countries. S p 10.52 03355 Rev J Updated 10/2021 © 2021 Victaulic Company. All rights reserved. I victaulic.com 5 \/(tauIicr I I I