Loading...
HomeMy WebLinkAbout5411 COLUMBUS CR; BLDG 68; AS120061; Permit8/17/22,10:14 AM AS120061 Permit Data City of Carlsbad Sprinkler Permit Job Address: 5411 COLUMBUS CR Permit Type: SPRINK Parcel No: 2111310700 Lot #: 0 Permit No: AS120061 Status: APPROVED Applied 6/13/2012 Approved: 6/20/2012 Reference No.: Issued: 6/20/2012 PC #: Inspector: Project Title: MARBRISSA RESORT BLDD 68 UG FS NEW UIG FIRE SERVICE MAIN FOR MARBRISSA RESORT VILLAS AND CLUBHOUSE Applicant: SOUTHERN CALIFORNIA FIRE PROTECTION, INC. STE8 27665 FORBES RD LAGUNA NIGUEL, CA 949-348-9600 Owner: GRAND PACIFIC CARLSBAD L P 5900 PASTEUR CT #200 CARLSBAD CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 360 0 360 U 1/1 Carlsbad Fire Department Plan Review Requirements Category: SPRINK , UNDGD Date of Report: 06-13-2012 Reviewed by: Name: SOUTHERN CALIFORNIA FIRE PROTECTION, INC. Address: STE 8 27665 FORBES RD /_ LAGUNA NIGUEL, CA Pe it#:A5120061 Job Na e: gLJ Job Addres. 1 COLUMBUS CR CBAD INCOMPLETE The item you have submitted for review is incomplete. At this time, this office cannot adequately conduct a review to determine compliance with the applicable codes and/or standards. Please review carefully all comments attached. Please resubmit the necessary plans and/or specifications, with changes "clouded", to this office for review and approval. Conditions: Cond: C0N0005465 [NOT MET] Underground water service mains for fire protection may only be approved by the Carlsbad Fire Department. Submittals of any Underground systems shall be made directly to the Carlsbad Fire Department and shall not be included with Overhead sprinkler plans other than "For Reference Only". No third-party plan reviewer has the authority to 'approve' plans to be submitted to the Carlsbad Fire Department. Entry: 05/29/2012 By: OR Action: CO Cond: C0N0005460 [NOT MET] A underground flush of all service mains shall be witnessed by the fire department prior to connecting to the overhead system. Failure to comply with this item shall result in a back-flushing of the entire overhead system through to the fire department connection. Entry: 05/29/2012 By: OR Action: CO Cond: C0N0005461 [NOT MET] All metal placed underground shall be protected against corrosion by those methods outlined in the San Diego Area Regional Standards Drawings and Carlsbad Fire Department Guidelines (see attached), this shall include polysleeve and and greasing or waxing as required. This process requires a visual inspection prior to burial. Failure to obtain an inspection prior to covering or burial wilil result in excavating all unapproved and un-inspected work. Entry: 05/29/2012 By: GR Action: CO Cond: C0N0005462 [NOT MET] Provide the underground pipe size, length, location, weight, material, point of connection to city main; the type of valves, meters, and the depth that the top of the pipe is laid below grade. You shall provide all installation and construction details as approved in the San Diego Area Regional Standards Drawing and Carlsbad Fire Department Guidelines. These notes shall be included on all submittal drawings. Entry: 05/29/2012 By: GR Action: CO Cond: C0N0005463 [NOT MET] Provide the pipe type and schedule of wall thickness. All materials shall comply with San Diego Area Regional Standards Drawings and Carlsbad Fire Department Guidelines. Entry: 05/29/2012 By: GR Action: CO Cond: C0N0005464 [NOT MET] Provide the current cut sheets from manufacturer and all relevent data as to the proposed materials to be used in constructing this underground service main and compliance with the San Diego Area Regional Standards Drawing and Carlsbad Fire Department Guidelines. Entry: 05/29/2012 By: GR Action: CO Cond: C0N0005466 [NOT MET] Drawings shall show complete 'looped' water main as will be required. Show location of each backflow prevention device serving each building or group of buildings. Fire Department Connections (FDC) shal be located no less than forty- (40) lineal feet from any structureand shall be accessible to fire apparatus along an approved vehicle route and within ninety- (90) lineal feet of a fire hydrant. Prior to connection of underground service main to the overhead fire sprinkler system, the underground system after being flushed, shall be hydraulically flow tested to ensure that the service main is of sufficient design and capacity for the overhead system demands. Entry: 05/29/2012 By: GR Action: CO