Loading...
HomeMy WebLinkAbout2710 GATEWAY RD; ; FA130016; Permit8/17/22, 11:26 AM FA130016 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2710 GATEWAY RD Permit Type: FALARM Parcel No: 2132631200 Lot #: 0 Reference No.: PC #: Permit No: FA130016 Status: ISSUED Applied 3/19/2013 Approved: 3/19/2013 Issued: 3/19/2013 Inspector: Project Title: CONTINUITY PRODUCTS T.I. Applicant: RIVER FIRE & SECURITY INC. 8920 ACTIVITY RD STE J SAN DIEGO, CA 858-752-6250 Owner: U RLLC P0 BOX 743 RANCHO SANTA FE CA Fees Add'I Fees ($) Total ($) Balance 286 0 286 0 1/1 Continuity Products 2710 Gateway Road Carlsbad, CA. 92011 Fire Alarm Submittal 03/14/13 Submitted By: RIVER FIRE 8920 Activity Rd. San Diego, California 92126 License#96646 CB122J.7G w I 'I Continuity Products Fire Alarm Submittal Equipment List Description Model Manufacture CSFM# Fire Alarm Panel 5104 SILENT KNIGHT 7165-0559:114 Smoke Detector 4W-B SYSTEM SENSOR 7272-1653:152 Pull Station BG- 12 Fire Lite 7150-0075:184 Horn/Strobe HSW Wheelock 7125-0785:168 Connection to Existing Waterflow,Tampers, PIV switches Lot Wire 18/2 Cond. (Initiation) Lot Wire 14/2 Cond. (Notification) - FIRE ALARM ACCESSORY r SILENT 5104B Fire Control J KNIGHT \Communicator by Honeywell The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six-zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions. It transmits via ordinary phone lines - eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard - the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1-800-328-0103. Model 51046 the central station. If one of the Fire Control Communicator telephone lines faults for more than The Silent Knight Model 5104B is a' 60 seconds, it will automatically 'six-zone fire control communicator, switch to the other to report the providing digital fire reporting over failure. ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-alone unit, it can be used to monitor: Sprinkler systems for waterfiow, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to The communicator will signal activation, restoration and trouble conditions on any of six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications. Features UL 864 Listed as an NFPA72 Central Station or Remote Station protected premise unit. FM approved. Can be used as a stand-alone or as a add-on DACT. : Six fully supervised inputs one Class A (Style D) input, and five Class B (Style A) inputs. Downloadable for remote programming. Fuseless overload protection with automatic reset circuitry and fault indicators - eliminates the cause of most field calls. L;4 1I Model 5104B Dual phone line interface Automatic self tests every 24 hours with report sent to central station. Reports in SIA and most major communications formats. 60 hours of standby power. Operates on loop start phone lines ahead of the building PBX system. A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes). FIRE ALARM ACCESSORY 5104B Fire Control, Communicator Specifications Electrical Add-on Applications - UL Listed Input: 120 VAC 60 Hz 40 watts 'Current: Standby, '50 mA' Alarm, 135 mA` Stand Alone Applications Input: 120 VAC 60 Hz 40 watts Standby: 12 volt 7 amp hour rechargeable battery 5230 Remote Annunciator (three maximum per system) Load: 60 mA standby 120 mA alarm Indicator Lights (LEDs): Power On (Green) Trouble Silenced (Yellow) Until Trouble is Cleared/Flashing = Supervisory Dialer Failure (Yellow) Telephone Line Fault (2 Red) Inside Cabinet at LI and L2 Inputs Telephone Requirements: FCC Registration #: AC698R-1 7462-AL-E RINGER EQUIVALENCE 0.01B Type of Jack: RJ31X (2 required) Mechanical: Dimensions: 12.25' W x 14.5" H x 3.0" D (31.1cm Wx36.8 cm Hx7.6cm D) Weight: 15 lbs. (6.75 kg) Color: Red 'Optional Accessories p230 Remote Annunciator/Programmer 5561 Download Package 7181 Fire Zone Converter Module 7860 Telephone Connecting Cord for RJ3IX Jack (2 required) 6712 12 volt, ZAH rechargeable battery Communication Formats: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK 4/2, Radionics BFSK Approvals: UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service. FM Approved CSFM Approved MEA = DDDDD DDDGDG Model 5230 'Model 5230 Remote Alphanumeric Annunciator The 5104B can be programmed through the use of the optional Model 5230 Remote Alphanumeric Annunciator. Programming options inc,ude: telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, user and installer codes. System programming is stored in a non- volatile EEPROM chip which is reprogrammable hundreds of times. The 5104B accommodates up to three remote annunciators via a four-wire connection. A quick- connect plug allows temporary connection of the annunciator for programming. The Model 5560 SKSS Downloading Package Allows for remote programming and status checking of the 5104; Includes a 3 1/2-inch disk and Silent Knight proprietary modem. Allows the installing company to view the default programming, modify it, and if necessary, troubleshoot the system. Designed to be used on an IBM or compatible PC. The downloading software also contains programs for other Silent Knight downloadable products. 5 1/4-inch disks available upon request. 6 Channel Silent Knight Communicator Model 5230 (optional) Remote Annunciator (3 max per system) Tel. Line #1 Model 6712 To RJ3IX 12VDC7AH Tel. Line #2 101 'Wheelock MB-GI0-12-R Class A Input (supervised) C Max 5 waterflow devices as per NFPA 12 C Class B Inputs (supervised) Gate valve tamper or Ply supervisor -must connect normally open FIRE ALARM ACCESSO 5104B Fire Control Communicator - 120VAC 60 Hz UL-LISTED LOCAL FIRE SILENT KNIGHT CONTROL MODEL 5104B 6 Channel Communicator Alarm Contact Trouble Contact (N.C. Typical) Went Knigh Model 5230 (optional) Remote Annunciator (3 max per system) Tel. Line #1 To RJ3IX Tel. Line #2 MODEL 5104B BLOCK DIAGRAM Add-On DACT Application SILENT KNIGHT MODEL 51048 I20VAC 60 Hz MODEL 5104B BLOCK DIAGRAM Stand-alone Waterflow Application 5104B Fire Control Communicator SILENT KNIGHT MODEL 5104B I20VAC 60 Hz Class A Input (supervised) I 6 Channel Silent Knight Model 5230 Communicator I (optional) Class B Inputs (supervised) Heat detectors, manual pull stations and contact type smoke detectors B Remote Annunciator (3 max per system) Tel. Line #1 rel / Wheelock MB-GiO-12-R (optional) F Model 6712 I2VDC7AH To RJ3IX Tel. Line #2 MODEL 5104B BLOCK DIAGRAM Stand-alone Automatic Fire Detection Application (For Communication Only) ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries. The secondary approved digital communicator to telephone line (number) at alternating supply shall be capable of supplying transmit the fire alarm and supervisory 24-hour intervals in accordance with power, under maximum normal load, and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or The digital communicator shall be UL signal if the telephone service is proprietary applications or 60 hours for or FM listed for fire reporting to a interrupted for longer than 60 seconds remote supervising station system central station and shall conform to the and it shall transmit a signal indicating application in accordance with NFPA requirements of NFPA 72. the loss of phone line service to the 72. central station over the remaining Th chII Ka nkinh- The digital communicator shall provide power and necessary components for six supervised detection circuits. One shall be Class A (Style 0) and five shall be Class B (Style A). The detection circuits shall accommodate sprinkler flow switches, gate valve supervisory switches, thermal detectors and contact-type smoke detectors intermixed as desired and permitted by NFPA 72. The control/communicator shall have the capability to supervise two telephone lines, seize the phone line phone line. A signal shall also be transmit all signals in the Standard SIA transmitted to indicate the restoral of format (Security Industry Association). phone service. The control/communicator shall be able to report the loss of either phone line without regard to which phone line failed first. If both lines fail, a local signal shall sound. The control/communicator shall have the ability to send a test signal to the central station every 24 hours. The test signal shall be able to be transmitted at a specific time of day or night by setting a program within the panel. The alarm signals transmitted to the central station shall indicate which of the six zones is in alarm and which zones are in trouble. Restoral from alarm or trouble shall be capable of communicating to Silent Knight, and other industry standard receivers. SILENT This document is not intended to be used for installation purposes. We try to MADE IN AMERICA KNIGHT keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are PN 350349, Rev Cl subject to change without notice. For more information, contact Silent Knight ©2010 Honeywell International Inc. by Honeywell 12 Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203) 484-7118. www.silentknight.com REMOTE ANNUNCIATOR D SILENT 5230 Remote Annunciator KNIGHT 01 Program and operate the 5104, 5204, or by Honeywell 5207 FACP from a distance with the 5230 remote annunciator. The 5230 remote annunciator provides remote annunciation for the 5104 Fire Communicator, 5204 Fire Alarm Control Panel (FACP), and 5207 FACP. The 5230 performs all system operations. It also provides trouble and alarm information and can be used for programming. The 5230 is also used to program the 5128/29 Fire Slave Communicators. For more information about the 5230, or to locate your nearest source, please call 1-800-328-0103. Description The 5230 is a remote annunciator that provides both trouble and alarm annunciation, and a convenient means for programming the 5104, 5204, and the 5207. When the system is normal and receiving AC power, the power LED is on. Users identify themselves to the control panel by entering a code on the annunciator. When a user presses a button, the annunciator piezo beeps and the LCD prompts the user to enter a code or other relevant information. Features 2-line 16-character LCD display Indicates Trouble, Alarm, Supervisory, and System Status conditions with LEDs and LCD display Each 5230 individually supervised by the FACP 12 to I8AWG wire with up to 1000 ft wire runs from FACP Easily set ID using four dip switches on back of unit Installation Mounts to dual gang electrical box with the rear mounting plate. Compatible Products 5104 3 per Communicator 5204: 3 per FACP 5207: 7 per FACP 5128/29: Programming only Approvals NFPA72 UL Listed CSFM 7165-0559: 111 MEA 429-92-E C POWER - FIRE ALARM NOML S:20 ANNUNCIATOR LJEEflSL] L1 KT 11 El 0 D E [1 L1] - 5230 Specifications Electrical Operating Voltage: 12 VDC 'Currenf Standby: 25 mA' Alarm: 40 mA', Physical Dimensions: 6.9" W x 4.25" H x I'D 14.46 cm W x 10.79 cm H x 2.54 cm D Environmental Operating Temp: 320 to 120° F (00 to 49° C) Maximum Wiring Distance: 1000 ft. Ordering Information 5230 Remote Annunciator Note: a 5230 Remote Annunciator Engineering Specifications The contractor shall furnish and install where indicated on the plans, the Model 5230 Remote Annunciator. Module shall be of a LCD type with a 2X16 display. Module shall be capable of remote programming as well as providing alarm, trouble information along with resetting of alarms and silencing of trouble and alarm conditions. Module ID shall be programmed with a 4 position DIP. The control shall be capable of supporting a minimum of 3 supervised 5230. Module shall be designed to mount on a single or dual gang electrical box with 18 gauge to 14 gauge wire. Wiring the 5230 This document is not intended to be used for installation purposes. We try to rcj SILENT keep our product information up-to-date and accurate. We cannot cover all KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 by Honeywell Clintonville Road, Northford, CT 06472-1610. Phone: (800) 328-0103, Fax: (203)484-7118. www.silentknight.com MADE IN AMERICA FORM# 350382 Rev B © 2010 Honeywell International Inc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:0114 Page 1 of I CATEGORY: 7165-- FIRE ALARM CONTROL UNIT (COMMERCIAL) LISTEE: SILENT KNIGHT SECURITY7550Meridian Circle, Maple Grove, MN 55369-4927 Contact: Michael Mclsaac (763) 493-6400 Fax (763) 391-5464 Email: mike.mcisaac@honeywell.com DESIGN: 'Model *5104B.'! Provides automatic, manual and waterflow service when used as a central station protective premise unit. Intended to monitor various initiating devices and transmit to a central station receiving unit various preprogrammed alarm and trouble signals. Refer to listee's data sheet for detailed product description, electrical rating and operational considerations. 5104B' -six-zone control/communicator control unif ,5230 Remote annunciator/keypad INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed control unit for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 9th Edition Standards. NOTE: Refer to listee's data sheet for required/optional accessories. When required, accessories shall be CSFM listed. *Rev. 08-01-12 gt This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013' Authorized By: JAMES PARSEGIAN, Program Coordinator Fire Engineering Division 5TEI C 4 Photoelectric Smoke Detectors System Sensor i series smoke detectors represent sign/f/cant advancement in con yen tional detection. The i family is founded on three principles: installation ease, intelligence, and instant inspection. FM TM Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang back boxes, 4-square back boxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement Wide-angle, dual-color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings @ <~> 0 MEA MSFM LISTED APPROVEO approved approved .0 . S911 3011446 7272-1653:152 290-01-E 2093 3180932 Installation ease.The P Jine'redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (included with heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, P heads plug into the base with a simple Stop-Drop 'N Lock' action. Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire l detectors can generate a remote LED- indicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof I3 detectors in terms of percent-per-foot obscuration. Instant inspection. The P series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. (j) Smoke Detector Smoke detector shall be a System Sensor i3 Series model number , listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems. The detector shall be a photoelectric type (Model 2W-13, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 35°F (57.2°C). The detector shall include a mounting base for mounting to 3/2-iflch and 4-inch octagonal, single-gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type. The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the UL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms. The detector shall provide dual- color LED indication that blinks to indicate power up, normal standby, out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel and shall provide a loop testing capability to verify the circuit without testing each detector individually. Operating Voltage Nominal: 12/24 V non-polarized Minimum: 8.5V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average: 4-wire: 50 pA maximum average' Maximum Alarm Current 2-wire: 130 mA limited by control panel;4-win/ 20 mA @12 V,23 mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-'wire: n/a' Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @30 V AC/DC Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz (178 g) Operating Temperature Range 2W-B and 4W-B: 32°F to 120°F 0°C to 49°C); 2WT-B and 4WT-B: 32°F to 100°F 0°C to 37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor -- 135°F (572°C) fixed Freeze Trouble 2WT-B and 4WT-B only: 41°F(5°C) Sensitivity 2.5%/ft nominal Input Terminals 14 to 22 AWG Mounting 3'/2-inch octagonal back box 4-inch octagonal back box Single-gang back box 4-inch square back box with a plaster ring Direct mount to ceiling LED Mode Green LED Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Orderinq Information 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel °4-wire' OrnA@12V,23 mA' @24V, 4WT-B Yes 4-wire 20 mA @ 12 V, 2 3 mA @ 24 V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / replacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 inch (16.76 cm) diameter S 0,200 Sten 3825 Ohio Avenue. St. Charles, IL 60174 V Phone: 800-SENSOR2. Fax: 630-377-6495 A05-0318-007 6/09 - #2169 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:0152 Page 1 of 1 CATEGORY: 7272 -- SMOKE DETECTOR SYSTEM TYPE-PHOTOELECTRIC LISTEE: 'System Sensor Unincorporated Div of Honeywell Intl Inc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: 'Models'2W-13, 2WT-B,4W4and 4W1-Bphotoelectnc type smoke detectors' Models 2W-B and 2WT-13 are 2-wire and model 4W-B and 4WT-B are 4-re detectors. Models 2WT-B and 4W1-B employ a thermistor type heat sensor (135°F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5 - 35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 if/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 'Listing Expires June 30, 2013 Authorized By: JASON DEWI1T, Deputy State Fire Marshal Fire Engineering Division DF-52004:A1 • F-050 \BGI 2 Series,, :Manual Fire Alarm Pull Stations: The Fire-Lite BG-1 2 Series i a cost-effective, feature-packed series of non-coded manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of mod- els including single- and dual-action versions. The BG-12 Series provides Fire-Lite Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a man- ual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting options make the BG-12 Series simple to install, maintain, and operate. Features Aesthetically pleasing, highly visible design and color. Attractive contoured shape and light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated(single- or dual-action), yet designed to pre- vent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down position to clearly indicate the station has been operated. The word "ACTIVATED" appears on top of the handle in bright yellow, further indicating operation of the station. Operation handle features white arrows showing basic opera- tion direction for non-English-speaking persons. Braille text included on finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patented hex-lock needs only a quarter-turn to lock! unlock. Station can be opened for inspection and maintenance with- out initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head captive 8/32 screws for easy connection to Initiating Device Circuit (lDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG!3.1 mm2). Terminal numbers are molded into the backplate, eliminating the need for labels. Switch contacts are normally open. Can be surface-mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4(10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by 1/2 (1.27 cm). Optional trim ring (BG12TR). Spanish versions (FUEGO) available (BG-12LSP, BG-12LPSP). Designed to replace the Fire-Lite legacy BG-10 Series. Models packaged in attractive, clear plastic (PVC), clam- shell-style, Point-of-Purchase packages. Packaging includes a cutaway dust/paint cover in shape of pull station. S N Construction Cover, backplate and operation handle are all molded of durable polycarbonate material. Cover features white lettering and trim. Red color matches System Sensor's popular SpectrAlert® Advance horn/strobe series. Operation The BG-12 manual pull stations provide a textured finger-hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the sta- tion, provided for non-English-speaking people. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word 'ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key, twist one quarter- turn, then open the station's front cover, causing the spring- loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. DF-52004:A1 • 04/22/08 Page 1 of 2 Specifications PHYSICAL SPECIFICATIONS: pull station SB-I 10 SB-ID Height 5.5 inches 5.601 inches 5.5 inches (13.97 cm) (14.23 cm) (13.97 cm) Width 4.121 inches 4.222 inches 4.121 inches (10.47 cm) (10.72 cm) (10.47 cm) Depth 1.39 inches 1.439 inches 1.375 inches (3.53 cm) (3.66 cm) (3.49 cm) 52004dm.ibi ELECTRICAL SPECIFICATIONS: Switch contact ratings: gold-plated; rating 0.25 A © 30 VAC or VDC. ENGINEERING/ARCHITECTURAL SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of red colored LEXAN (or polycarbonate equivalent) with clearly visible operating instructions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (2.54 cm) or larger. Stations shall be suitable for surface mounting on matching backbox SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double-gang, or 4' (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Under- writers Laboratories listed. NOTE: *The words FlRE/FUEGO" on the BG-12LSP shall appear on the front of the station in white letters, approximately 3/4" (1.905 cm) high. If FUEGO/FIRE DOWN Agency Listings and Approvals The listings and approvals below apply to the BG-1 2 Series pull stations. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. C(UL)US:S711 FM Approved CSFM: 7150-0075:184 MEA:67-02-E Patented: U.S. Patent No. 0428,351; 6,380,846; 6,314,772; 6,632,108. Product Line Information BG-125: Single-action pull station with pigtail connections, hex lock. BG-12SL: Same as BG-12 with key lock. 13G-12: Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock BG-12L: Same as BG-12 with key lock. BG-12LSP: Same as BG-12L with English/Spanish (F/RE! FUEGO) labeling. BG-12LOB: Same as BG-12L with "outdoor use" listing. Includes outdoor listed backbox, and sealing gasket. BG-12L0: Same as BG-12L with "outdoor use" listing. Does not include backbox. BG-12LA: Same as BG-12L with auxiliary contacts. BG-12LPS: Dual-action pull station with pre-signal option. BG-12LPSP: Same as BG-12LPS with English/Spanish (F/RE! FUEGO) labeling. SB-10: Surface-mount backbox, metal. SB-I/O: Surface-mount backbox, plastic. (Included with BG- 12LOB.) BG12TR: Optional trim ring for semi-flush mounting. 17003: Keys, set of two. (Included with key-lock pull stations.) 17007: Hex lock, 9/64". (Included with hex-lock pull stations.) NOTE: For addressable BG- 12LX models, see data sheet DF- 520 13. Fire-Lite® Alarms, SpectrAlerttt) Advance, and System Sensor® are registered trademarks of Honeywell International Inc. ©2008 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. Iso 9001 We try to keep our product information up-to-date and accurate. RJULaw We cannot cover all specific applications or anticipate all requirements. ENlNflNG 9 111111111111FAMRING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S. A. For more information, contact Fire-Lite Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. www.firelite.com Page 2 of 2— DF-52004:A1 • 04122/08 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 17150-0075:0184 Page 1 of I CATEGORY: 7150 -- FIRE ALARM PULL BOXES LISTEE: FIRE-LITE ALARMS INC.One Fire-Lite Place, Northford, CT 06410-1653 Contact: Brian Reynolds (203) 484-7161 Fax (203) 484-7309 Email: Brian.Reynolds2Honeywell.com DESIGN: Models BG-12,'BG-12S, BG-I2NC, BG-12W, BG-I2LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-I2PS, BG-I2LSP, BG-I2SP, BG-I2LR, BG-I2LRA, BG-12LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-I2LPS, BG-12LPSP, BG-12SL, UT-PSi and UT-PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-1 0 back box. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition and California amendments. XLF: 7150-0028:0199 *Updated 08-17-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed SJ the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires 'June 30, 2013' Authorized By: JASON DEW/iT, Deputy State Fire Marshal Fire Engineering Division - Save up to 48% in current draw* - Up to 9 models now in 1 appliance - Save up to 14% cost of installation** "0 Sleek Modern Aesthetics W. Finger Slide Switches ( g 8 Candela Settings Wall - 15/1575130175195/1101135/1 85 Ceiling - 15/30/60/75/95/115/150/177 Universal Mounting Base U Ceiling and Wall Mounts to 5 Backbox Types Environmentally Friendly Low Current Draw (_!_~ Voltage Test Points Multiple Voltages 3 Audible Settings 90, 95,99 dB E?JÔEDTM Strobe,Horn Strobe, and Horn Notification Appliances Description: The Wheelock® ExcederlM Series of notification appliances feature a sleek modern design that will please building owners with reduced total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting chaiges, voltage test points, 12/24 VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. The Wheelock® ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit. All strobe models feature an industry first of 8 candela setings on a single appliance. Models with an audible feature 3 sound settings (90, 95, 99 dB). All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of hons, strobes, and combination horn strobes. The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt, dust, paint and damage to the contacts. The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed The UMB allows for consistent installation and easy replacemert of appliances if required. Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Compatibility and Requirements -Synchronize using the Wheelock Sync Moc ules or panels with built-in Wheelock Patented Sync Protocol - Compatible with UL "Regulated Voltage" usng filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the "Regulated Voltage" range * Compared to competitive models Pater:ted Compared to previous models I NOTE: All CAUTIONS and WARNINGS are identified by the symbol A. All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING, SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS, CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION, WHICH COULD RESULT IN PROPERTY DAMAGE, AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: Strobes are designed to flash at I flash per second minimum over their Regulated Voltage Range'. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32SF to 120F (OC to 49C) and maximum humidity of 93% (± 2%) UL 464(85% UL 1971). Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Horn Strobe Ratings per UL 1971 & Anechoic at 24 VDC UL Max Current* at Anechoic 99 dBA 24 VDC 12 vDc Regulated Voltage Model 15 15/75 30 60 75 95 110 115 135 150 177 185 '15 15/75 Range VDC F-IS, 8.0-33.0 0.082 0.095 0.102 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 0.125 UL Max Current* at Anechoic 95 dBA 7ModelRegulated 24 VDC 12 VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 0.139 0.163 0.186 0.230 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 0.186 0.230 0.272 0.122 UL Max Current* at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0.084 0.136 0.157 0.184 0.226 0.267 HSC 8.0-33.0 0.065 0.084 0.120 0.136 0.157 0.184 0.226 0.267 0.120 0.120H0.148 HornRatings per UL Anechoic - - - Model Regulated Voltage Range VDC 99dB 95dB 90dB HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 HNC 8.0-17.5 0.047 0.026 0.017 * UL max current rating is the maximum R M S current within the listed voltage range (16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage (33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information *12 VDC models feature 15 & 15/75 settings **UMB = Universal Mountino Base Model Legend HN = Horn A =Agent Letterng ST = Strobe (Strobes only) HS = Horn Strobe AL = Alert Lettering C = Ceiling Mount (Strobes only) W = White N =No Lettering R = Red (Strobes only) Example 1: STRC = Strobe, Red, Ceiling Mount Example 2: HSR = Horn Strobe, Red, Wall Mount Example 3: HSW = Horn Strobe, White, Wall Mount Example 4: STW-AL = Strobe, White, Wall Mount, Alert Lettering ct ( •,. Example: HSWC I I . 1 ljtJlj 4 .4 *(J MB Contact Cover NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc., dba Cooper Notification standard terms and conditions. Notification Wheelock' IMEDCJ SAFEPATIt wAV-05 Architects and Engineers Specifications The notification appliances shall be Wheelock' Exceder' Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals. The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired) for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464 (Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP) with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan lens. The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g. ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3) audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel (FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58" W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58" W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock''s DSM Sync Modules, Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock® Patented Sync Protocol. The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1) flash per second over its Regulated Voltage Range. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock® synchronization protocol. Wall Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM Ceiling Appliances - UL Standard 1971, UL Standard 464, California State Fire Marshal (CSFM), ULC, FM WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder - Spec Sheet 6/11 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785016& Page 1 of I CATEGORY: 7125- FIRE ALARM DEVICES FOR THE HEARING IMPAIRED LISTEE: Cooper Wheelock lnc7246 16th St. E., Ste. 105, Sarasota, FL 34243 Contact: Tom Conover (941) 487-2336 Email: thomas.conovercooperindustries.com DESIGN: Exceder Series:' Models ST strobejHS horn strobe' and HN horn. Model ST is a synchronous and non-synchronous strobe light. Model HS a visual/audible appliance and Model HN is an audible signal appliance. All units followed by R (red) or W (white). Additionally, a 'C' may be added for ceiling models and/or a -NR' may be added for non-resettable models. For non -NR models and optional 'S for silver fascia may be added*. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 12 VDC/24VDC/FWR Candela (wall)*: 15, 15/75, 30, 75, 95, 110, 135 & 185 Candela (ceiling)*: 15, 30, 60, 75, 95, 115, 150, & 177 INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. All models are for indoor use and for wall mount only or ceiling mount only* MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as horn for fire alarm signaling and strobe, horn/strobe for the hearing impaired when used with separately listed electrically compatible fire alarm control units. Refer to listee's Installation Instructions Manual for details. *Rev. 9-24-09 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 "Listing Expires, 'June 30, 2013, Authorized By: JASON DEWI1T, Deputy State Fire Marshal Fire Engineering Division