Loading...
HomeMy WebLinkAbout2675 GATEWAY RD; ; AS080187; Permit8/17/22, 11:24 AM AS080187 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS080187 Job Address: 2675 GATEWAY RD Status: ISSUED Permit Type: SPRINK Applied 12/29/2008 Parcel No: 2131910800 Approved: 12/29/2008 Lot #: 0 Reference No.: Issued: 12/29/2008 PC #: Inspector: Project Title: BOARD & BREW RESTAURANT T.I. FIRES PRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: 1 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 1/1 tqC0 /Fire & Building I Products Technical Services: Tel: (800) 381-9312 I Fax: (800) 791-5500 Series TY-FRB 2.8, 4.2,. 56, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The Tyco® Series TY-FRB, 2.8, 4.2, 5.6, and 8.0 K-factor, Upright and Pen- dent Sprinklers described in this data sheet are quick response - standard coverage, decorative 3 mm glass bulb type spray sprinklers designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, shopping malls, etc. The recessed version of the Series TY-FRB Pendent Sprinkler, where ap- plicable, is intended for use in areas with a finished ceiling. It uses either a two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Es- cutcheon with 1/2 inch (12,7 mm) of recessed adjustment or up to 3/4 inch (19,1 mm) of total adjustment from the flush pendent position, or a two-piece Style 20(1/2 inch NPT) or Style 30(3/4 inch NPT) Recessed Escutcheon with 1/4 inch (6,4 mm) of recessed adjust- ment or up to 1/2 inch (12,7 mm) of total adjustment from the flush pen- dent position. The adjustment pro- vided by the Recessed Escutcheon re- duces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- IMPORTANT Always refer to Technical Data Sheet TFP 700 for the INSTALLER WARNING" that provides cautions with respect to handling and instal- lation ofsprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. tamed when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these coatings for any given corro- sive environment. The effects of ambi- ent temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level versions of the Series TY-FRB Pendent Sprinklers are detailed in Technical Data Sheet TFP356, and Sprinkler Guards are de- tailed in Technical Data Sheet TFP780 WARNINGS The Series TY-FRB Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers TVII3I - Upright 2.8K, 1I2"NPT TY1231 - Pendent 2.8K, 1I2"NPT TY2131 - Upright 4.21K, 1I2"NPT TY2231 - Pendent 4.2K, 1/2"NPT 1Y3131 - Upright 5.6K, 1/2"NPT TY3231 - Pendent 5.6K, 1/2"NPT TY4131 - Upright 8.0K, 3I4"NPT TY4231 - Pendent 8.0K, 314"NPT 1Y4831- Upright 8.0K, 112"NPT 1Y4931- Pendent 8.0K, 1/2"NPT Page 1 of 10 AUGUST, 2007 TFPI7I ESCUTCHEON PLATE SEATING SURFACE 7/16"(11,1 mm) NOMINAL 1/2" MAKE-IN IdOT 2-1/4" (57,2 mm) ESCUTCHEON PLATE SEATING SURFACE 7/16"(11,11 mm) NOMINAL MAKE-IN 1(2" NPT Page 2 of 10 TFPI7I STYLE 10 or 20 RECESSED SSu* ESCUTCHEON DEFLECTOR (11,1 mm) NOMINAL 7/16" MAKE-IN 2-3/16" WRENCH (55,6 mm) 7 FLATS 1/2" NPT t SSP DEFLECTOR* 1— 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 8 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression 7 - Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TYII3I) AND PENDENT (TY1231) SPRINKLERS 2.8 K-FACTOR, 1/2 INCH NPT T__ 2-3/16" (55,6 mm) STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7/16" L /VT11J\ (11,1 mm) I III II III NOMINAL MAKE-IN 2-3/16" AL I V WRENCH FLATS (55,6mm) 1/2"NPT P SSP DEFLECTOR * }—'-- 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION 1 - Frame 3-Sealing 4-Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2 - Button Assembly 5 - Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TV2131) AND PENDENT (TY2231) SPRINKLERS 4.2 K-FACTOR, 1/2 INCH NPT ESCUTCHEON PLATE SEATING SURFACE 7116"(11,1 mm) NOMINAL MAKE-IN 112" NPT 6* 111 TFPI7I Page 3 of 10 -r- 2-3116" (55,6 mm) T STYLE 10 or 20 RECESSED SSU* ESCUTCHEON DEFLECTOR 7/16" (11,1 mm) E-IN WRENCH MAK NOMINAL FLATS _____ mm) 1!2"NPT SSP DEFLECTOR * - 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT UPRIGHT CROSS SECTION - Frame 3 - Sealing 4 - Bulb 8 - Deflector * Temperature rating is Indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY3131) AND PENDENT (TY3231) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT STYLE 30 or 40 RECESSED ESCUTCHEON SSU* DEFLECTOR ESCUTCHEON 1/2"(12,7 mm) PLATE SEATING NOMINAL SURFACE MAKE-IN NPT 2-5/16" (58,7 mm) W 1 1-9/16" (39,7 mm) 6* WRENCH FLATS SSP DEFLECTOR * I 2-718"(73,Omm)DIA. PENDENT RECESSED PENDENT 314"NPT UPRIGHT CROSS SECTION 2-1/4" (57,2 mm) 1 - Frame 3- Sealing 4- Bulb 6- Deflector 2 - Button Assembly 5 - Compression Screw * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT (TY4131) AND PENDENT (TY4231) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Page 4 of 10 TFPI7I 7/16"(11,1 mm) NOMINAL SSU * 1/2" MAKE-IN DEFLECTOR NPT *6 2-1/4" _ 2-3/1w __ 1-9/16" (57,2 mm) t f (II) WRENCHI U 1111 2 nvt (39,7 mm) I FLATS 3 sSP * DEFLECTOR CROSS PENDENT UPRIGHT SECTION 1 - Frame 3 - Sealing 4 - Bulb 6 - Deflector * Temperature rating is indicated on deflector or adjacent to 2- Button Assembly 5- Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT (1Y4831) AND PENDENT (TY4931) SPRINKLERS 8.0 K-FACTOR, 1/2 INCH NPT Technical Data Approvals UL and C-UL Listed. FM, LPCB, and NYC Approved. (Refer to Table A and B for complete approval information including corro- sion resistant status.) Maximum Working Pressure Refer to Table C. Discharge Coefficient K = 2.8 GPM/psi112 (40,3 LPM/b2r1/2) K = 4.2 GPM/psi112 (60,5 LPM/bar1l2) K = 5.6 GPM/psi112 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barll2) Temperature Ratings Refer to Table A and B Finishes Sprinkler: Refer to Table A and B. Recessed Escutcheon: White Coated, Chrome Plated, or Brass Plated. Physical Characteristics Frame .............Bronze Button .........Brass/Copper Sealing Assembly .......... Beryllium Nickel w/Teflont Bulb ...............Glass Compression Screw .....Bronze Deflector .......Copper/Bronze Bushing (K=2.8) .......Bronze Operation The glass Bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Series TY-FRB Pendent and Up- right Sprinklers are intended for fire protection systems designed in ac- cordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Pre- vention Data Sheets ). Only the Style 10, 20, 30, or 40 Recessed Escutch- eon, as applicable, is to be used for recessed pendent installations. TFPI7I SPRINKLER FINISH (See Note 7) K TYPE TEMP. BULB LIQUID NATURAL BRASS J CHROME PLATED I WHITE* 1POLYESTER 2.8 1/2" PENDENT (TY1231) and UPRIGHT (TYII3I) 135°F157°C Orange 1,2,3,5 155°F/68°C Red 175"F/79°C Yellow 200"F/93°C Green 286°F/141"C Blue NPT 135°F/57"C Orange 1, 2, 5 RECESSED PENDENT (TY1231)* Figure 6 155°F/68°C Red 175°F/79"C Yellow 200°F/93°C Green 135"F/57°C Orange RECESSED PENDENT (Ty1231)- Figure 7 155°F168°C Red 175°F/79°C Yellow 200"F193°C Green 1/2" NPT PENDENT (TY2231) and UPRIGHT (TY4.2 2131) 135°FI57C I Orange 1,2 155°F/68°C Red 175°F179°C Yellow 200°F193°C Green 286°F1141"C Blue 135"F/57°C Orange RECESSED PENDENT (Y2231)* Figure 155"F168°C Red 175"F/79°C Yellow 200°F/93"C Green 135"F/57°C Orange RECESSED PENDENT (TY2231) Figure 9 155°F168°C Red 175°F179°C Yellow 200°FF93°C Green NOTES: - Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Re- sponse Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- klers. 5. Approved by the City of New York under MEA 354-01-E. 7. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 2.8 AND 4.2 K-FACTOR SPRINKLERS Page 5 of 10 Page 6 of 10 TFPI7I SPRINKLER FINISH (See Note 8) K I TYPE TEMP. BULB LIQUID NATURAL BRASS i CHROME i PLATED I WHITE* POLYESTER LEAD COATED - 5.6 PENDENT (TY3231) and UPRIGHT (TY3131) 135°F/57°C Orange 1,2,3,4,5,6,7 Blue 1,2,3,5 155°F/68°C Red 175"F/79°C Yellow 200"F193°C Green 286°F/141"C 1/2" NPT 135°F/57°C Orange 1,2,4,5 Green N/A RECESSED PENDENT (TY3231)* Figure 10 155°F/68°C Red 175°F/79°C Yellow 200°FI93°C 135°F/57°C Orange 1,2,3,4,5 Green N/A RECESSED PENDENT (TY3231) Figure 11 155°F168°C Red 175°F!79"C Yellow 200°F/93°C - 8.0 PENDENT (Ff4231) and UPRIGHT (Ff4131) 135"F/57°C Orange 1,2, 3,4, 5, 6, 7 1, 2, 5 155°F/68°C Red 175°F/79°C Yellow 2006F/93°C Green 286"F/141°C Blue 3/4" NPT 135°F/57°C Green 1,2,4,5 Yellow N/A RECESSED PENDENT (TY4231)" Figure 12 155°F168°C Orange 175"F179"C Red 200°F193°C 135°F/57"C Orange 1,2, 3,4,5 Green N/A RECESSED PENDENT (TY4231) Figure 13 155°F168°C Red 175°F/79°C Yellow 200"F193"C - 8.0 1/2" NPT PENDENT (Ff4931) and UPRIGHT (Ff4831) 135°F/57°C Orange 1,2,4,5,6 Blue 1, 2, 5 155°F/68"C Red 175°F179°C Yellow 2000FI93eC Green 286°F/141°C NOTES: Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k104) as Quick Response Sprinklers: however, the LPCB does not rate the thermal sensitivity of recessed sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a Corrosion Resistant Sprinklers. * Installed with Style 10 (1/2" NPT) or Style 40 (3/4" NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. ** Installed with Style 20 (1/2" NPT) or Style 30 (314" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). N/A: Not Available TABLE B LABORATORY LISTINGS AND APPROVALS 5.6 AND 8.0 K-FACTOR SPRINKLERS TFPI7I Page lot 10 SPRINKLER FINISH K TYPE NATURAL CHROME I WHITE LEAD BRASS PLATED POLYESTER COATED PENDENT (TY3231) and 2.8 UPRIGHT (TY3131) 175 PSI (12,1 BAR) N/A 112" RECESSED PENDENT NPT (TY323) PENDENT (TY4231) and 4.2 UPRIGHT (1Y4131) 175 PSI (12,1 BAR) N/A 3/4" RECESSED PENDENT NPT (TY4231) PENDENT (TY3231) and 250 PSI (17,2 BAR) 175 PSI (12,1 BAR) 5.6 UPRIGHT (1Y3131) OR 112" 175 PSI (12,1 BAR) RECESSED PENDENT NPT (TY3231) (SEE NOTE N/A PENDENT (TY4231) and 175 PSI (12,1 BAR) 175 PSI (12,1 BAR) 8.0 UPRIGHT (TY4131) RECESSED PENDENT NPT (TY4231) N/A 8.0 PENDENT (TY4931) 1/2" and 175 PSI (12,1 BAR) 175 PSI (121 BAR) NPT UPRIGHT (TY4831) NOTES: 1. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories Inc. (UL): the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL); and , the Approval by the City of New York. TABLE C, MAXIMUM WORKING PRESSURE Installation The Series TY-FRB Sprinklers must be installed in accordance with the fol- lowing instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 286°F/141°C temperature ratings. A leak tight 1/2 inch NPT sprinklerjoint should be obtained with a torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A maxi- mum of 21 ft. lbs. (28,5 Nm) of torque may be used to install sprinklers with 1/2 NPT connections. A leak tight 3/4 inch NPT sprinkler joint should be ob- tained with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum of 30 ft.lbs. (40,7 Nm) of torque is to be used to install sprinklers with 3/4 NPT con- nections. Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TY-FRB Pendent and Up- right Sprinklers must be installed in accordance with the following instruc- tions. Step 1. Pendant sprinklers are to be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 14). With reference to Figures 1, 2, 3, 4, and 5, the W-Type 6 Sprinkler Wrench is to be applied to the sprinkler wrench flats. The Series TY-FRB Recessed Pen- dent Sprinklers must be installed in accordance with the following instruc- tions. Step A. After installing the Style 10. 20, 30, or 40 Mounting Plate, as appli- cable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprin- kler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 15). With reference to Figure 1, 2, 3, and 4, the W-Type 7 Recessed Page 8 of 10 - 2-7/8" DIA. t 5/8±114" (73,0 mm) j 314"(19,1 mm) (15,916.4 mm) 2-1/4"D IA.. 1/4' (6,4 mm) FACE OF MOUNTING SPRINKLER PLATE FITTING 1/8" ,2mm ' I (3,2 mm) MOUNTING SURFACE SERIES 1-5/16" (33,3 mm) CLOSURE TY-FRB 13/16"(20,6 mm) FIGURE 6 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT - 2-7/8" DIA. - 5/8±1/4" (73,0 mm) I 314"(19,1 mm) (15,9±6,4 mm) 2-1/4" 01k 1/4" (6,4 mm) I FACE OF MOUNTING SPRINKLER PLATE I FITTING 1/8" I (3,2 mm) / MOUNTING/ SURFACE SERIES 1-1/4"(318 mm) I CLOSURE TYFRB 314"(19,1 mm) FIGURE 8 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT TFPI 71 2-7/8" DIA. - I (73,0 mm) 1/2±1/8" I 1/2"(12,7mm) 1 (12,7±3,2 mm) 2-1/4" 01k 1/4"(6,4 mm) I FACE OF mm) MOUNTING I SPRINKLER PLATE I FITTING / (32mm) CLOSURE SERIES (33,3 mm) 1/8" T-7— MOUNTING SURFACE TY-FRB 1-1116"(27,0 mm) FIGURE 7 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. - (73,0 mm) 1/2±1/8" 1/2"(12,7 mm) 1 (12,70,2 mm) 2-1/4' DIA. 114"(6,4 mm) I FACE OF (572mm) MOUNTING I SPRINKLER PLATE I /(3,2 I FITTING " 118 mm) t f MOUNTING SURFACE SERIES 1-1/4" (31,8 mm) I CLOSURE TY-FRB 1"(25,4 mm) FIGURE 9 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 1/2 INCH NPT Sprinkler Wrench is to be applied to the sprinkler wrench flats. Step C. After the ceiling has been in- stalled or the finish coat has been ap- plied, slide on the Style 10, 20, 30, or 40 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. Care and Maintenance The Series TY-FRB Sprinklers must be maintained and serviced in accord- ance with the following instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been corn- TFPI7I - 2-7/8' DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (15,9±6,4 mm) - 2-1/4' DIA 1/4' (6,4 mm) I MOUNTING I FACE OF PLATE SPRINKLER FITTING 1/8" (3,2 mm) MOUNTING/ SURFACE SERIES 1-1/4" (31,8 mm) CLOSURE TY-FRB 3/4"(19,1 mm) FIGURE 10 SERIES TY-FRB RECESSED PENDENT WiTH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT - 2-7/8' DIA. 518±1/4" (73,0 mm) 314"(19,1 mm) - (15,9±6,4 mm) 2-1/4' DIP,. I 1/4" (6,4 mm) FACE OF (57,2 MOUNTING SPRINKLER PLATE I FITTING 1/8" I __________ (3,2 mm) I I MOUNTING SURFACE CLOSURE SERIES 1-5/16' (33,3 mm1 TY.FRD 13/16" (20,6 mm) FIGURE 12 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT Page 9 of 10 - 2-7/8" DIA. (73,0 mm) 1/2±1/8' 1/2' (12,7 mm) F (12,7±3,2 mm) 2-1/4" DIA. 1/4' (6,4 mm) I II SPRINKLEqR PLATE I FACE OF 572 mm) -' MOUNTING I I FITTING I 1/8" MOUNTIN SURFACSERIES 1-1/4"(31,8 mm) CLOSURE TYFRB 1"(25,4 mm) FIGURE 11 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON 5.6K-FACTOR, 1/2 INCH NPT 2-718'DIA. 1/2±1/8' (73,0 mm) 1/2"(12,7 mm) (12,7±3,2 mm) 2-1/4" DIP,. 1/4' (6,4 mm) I I / (57,2mm) 1/8" FACE OF MOUNTING PLATE I SPRINKLER FITTING rill (3.2 mm)I I \ - MOUNTING SURFACE CLOSURE SERIES 1-5/16" (33,3 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 13 SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT plated, to verify the integrity of the cor- rosion resistant Coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- WRENCH RECESS (END "A" USED FOR 1/2' NPT MODELS) WRENCH RECESS (END 'B' USED FOR 3/4' NPT MODELS) FIGURE 14 W-TYPE 6 SPRINKLER WRENCH facturer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 15 W-TYPE 7 RECESSED SPRINKLER WRENCH Inspection Service in accordance with local requirements and/or national codes. P/N 57-XXX--X-XXX I MODEL/SIN 330 2.8K UPRIGHT (1/2"NPT) TY1I3I 331 2.8K PENDENT (112"NPT) TY1231 340 4.2K UPRIGHT (1/2"NPT) TY2131 341 4.2K PENDENT (112"NPT) 1Y2231 370 5.61< UPRIGHT (1/NPT) TY3131 371 5.6K PENDENT (112"NPT) TY3231 390 8.0K UPRIGHT (3I4NPT) TY4131 391 8.0K PENDENT (314"NPT) TY4231 360 8.0K UPRIGHT (1INPT) TY4831* 361 1 8.0K PENDENT (112"NPT) * 71 I I 1 SPRINKLER 135 155 175 200 286 RATING I NATURAL BRASS 155°F/68°C 4 WHITE POLYESTER 175°F/79°C 3 WHITE (RAL901O) 200F/93C 9 CHROME PLATED 286*F/141C 7 LEAD COATED * Eastern Hemisphere sales only. Page 10 of 10 TFPI7I TABLED PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. RWiTIiilIIIIl1 Ilre I1fc1i1I[tT.1 This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), Quick Response, (specify K-factor), (specify temperature rating), Series TY-FRB (specify Pendent or Upright) Sprinkler with (specify type of finish or coating), P/N (specify from Table 0). Recessed Escutcheon: Specify: Style (10, 20, 30, or 40) Re- cessed Escutcheon with (specify) fin- ish, P/N (specify*). * Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 0- - I a b"I FAIRIM d :I;14L1'i 1 Full Line Sch-40 Replacement Dyna-Thread5 offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison. to Schedule 4O- Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyn a-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40fDyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40fDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). NPS Nominal I.D. Wt. Wt. (H20 Filled) Pcs/ WIi1Jft (21') Wt/Lift (24') Wt/Lift (25') In; mm In; mm Lbs/Ft Kg/rn Lbs/Ft Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1 1.080 1.330 1.75 70 1955 2234 2327 25 27.4 2.0 2.60 70 887 1013 1056 11,44 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 1081 11,1 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 1143 2 2.104 3.050 4.57 30 1921 2196 2287 50 53.4 4.5 6.80 30 871 996 1037 llied 16100 S. Lathip Harvey, IL 60426 Customer Service: t',CO 11350 Norcom Rd. • Philadelphia, PA 19154 (800) 882-5543 a vital part of your world TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 FaX 708-339-1806 S3-3 FCn P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 310 RING RESTRAINER t Ping ing Hang estrainer SIZE One size fits 3/4 thru 2 inch AFCON#300 Ring Hanger. One size fits 2 1/2 and 3 inch AFCON#300 Ring Hanger. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTINGS - c us EX 2551 Listed only for use with AFCON#300 Ring Hanger. FUNCTION - To restrain movement of sprinkler pipe toward the knurl nut of the ring hanger. To prevent upward movement of pipe that supplies a pendent sprinkler below the ceiling. INSTALLATION - Per NFPA-13 on steel, CPVC, or copper pipe. Snap into locking position on swivel nut ofAFCON #300 Ring Hanger. FEATURES - * Listed only for use with AFCON #300 Ring Hanger. ORDERING - Part # and size. 10/06 112 and 314 inch pipe 5 thru8 inch pipe IMPERIAL MAX REC. LOAD LBS. METRIC PIPE ROD PIPE ROD 1/2 318 400 10 3/4 3/8 °° 20 10 400 25 to 11/4 3/8 400 32 to 11/2 3/8 400 40 10 400 50 10 21/2 600 10 3 r3/88 600 80 to 31/2 600 to 4 1000 ioo 5 1250 125 12 6 1250 150 12 8 1250 200 12 Order Part #300m Note: 1/2 Ring Hanger not (FM> approved P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 300 RING HANGER I thru 4 inch pipe LISTED FOR STEEUCPVC SIZE - 1/2 thru 8 inch pipe. MATERIAL - Carbon Steel, Mu. Galvanized to G-90 spec. LISTING/APPROVAL - ® 203-EX 2551 <S> Approval guide- Pijië Hungers OSHPD OPA-0601 See Website. CONFORMS WITH: Federal Specification WW-H- 171 (Type 10, Manufacturers Standardization Society ANSI/MSS-SP-58 (Type 10). MAXIMUM TEMPERATURE - 650°F. FUNCTION - Pipe hanger component for use on steel, CPVC or copper piping. INSTALLATION . Per NFPA-13, 13R and 13D. FEATURES - * Sized and listed exclusively for use with #310 Surge Restrainer. * Band edge is offset for EASY pipe insertion. * Custom fit swivel nut for better retention in ring body. * Full length knurl on swivel nut for better grip. ORDERING - Part #, pipe size. 2/07 [&IJ :1 LJiI :1h1i OW R025=12MMIN Weight Size A B block gals. lIPS/ON Idiom In/mm lbs/kg lbs/kg 1/4 1/7 13/16 0.22 0.23 8 is 22 0.! 0.1 3/ /s 1 0.35 0.36 10 16 25 0/6 0.16 ½ n/16 1½ 0.56 0.58 15 Ii 29 0.25 026 '/4 13/16 i/ts 0.84 0.85 20 22 33 0.38 0.39 I5 1112 1.3 1.3 25 24 38 0.57 0.59 1144 11/4 13/4 2 2.1 32 29 44 0.9 0.9 11/2 1-1116 15/ 2.7 2.7 40 33 49 1.2 1.2 2 ]9/ 21/1 4.2 4.3 50 40 57 1.9 2 2½ 1"/1e 21Yt6 6.7 6.8 65 47 68 3 3.1 3 2'/16 31/4 10 10 80 56 79 4.5 4.6 31/2 2/l6 37M 13 .14 90 62 87 6 6.3 4 21 '/14 3-1/4 16 17 00 68 95 7.4 7.7 5 35/j 41/2 27 28 125 84 114 12 /3 6 37/4 51A 41 41 /50 98 130 /9 /9 8 53/16 ON 79 81 200 /32 167 36 37 APPROVED For Listing / Approval details contact your AnvilStarTM Representative. Straight Tee AiiLBtar Fire Products Division of Anvil' international Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME-131 6.4 (except plugs 1/4 NPS - 1 2NPS (8 - 300 DN), are included in the "List of and bushings, ASME B 16.14). Dimensions also conform to I Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW-P-501 (except plugs and bushings the Underwriters' Laboratories, Inc. WW-P-471). NOTE: Seethe Technical Data section For pressure-temperature ratings. See AnvilStar Web site For the most current Listings and approvals. .. Project: Date: Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06.005 go to www.anvilstar.com or contact your local AnvilStar representative Concentric Reducers ()ANvIL Cast Iron Threaded Fittings Class 125 (Standard) iiti..Btar Fire Products Division of Arvilo International Submittal Sheet UL APPROVED For Listing / Approval details contact your AnvilStar°' Representative. - FIGURE 367 CONCE Size A B I black NPS/DN lIPS/UN In/mm lnjmnz 111S.14 ½ ½ 110 0.4 20 /5 16 40 0/8 'is 111A6 0.54 1 /5 17 43 0.24 25 &/t TA 6 17/2 0.63 20 II 39 0.29 1/7 IA6 1½ 0.84 15 /4 41 0.38 /1/4 3/4 1 21/8 1.1 32 20 25 54 0.49 1 1/16 21/8 1.1 25 24 54 0.49 1/2 1/3 15/8 1 /5 13 41 0,45 ~ 1½ 1.2 11/2 48 20 /3 41 0.54 1 1/2 1'A 1.5 25 /3 44 0.68 1½ 1 21/4 1.5 32 25 57 0.66 ½ ½ 2 2 15 /6 51 0.91 2 T/4 '/4 2 1.9 50 20 /9 1 51 0.86 1 3/4 2 1.8 25 19 51 0.93 I Size A I Weight black lIPS/ON I lIPS/ON In 1mm In/mm lbs/kg 11/4 13/n 21/8 1.8 2 32 22 54 0.81 so ½ 2 (Cod.) 1½ 2/o 40 22 56 0.9 11/2 3/4 2 3.1 2½ 40 19 51 1.4 65 2 1 21/to 3 50 25 65 1.4 3/4 17o 2½ 4.3 20 24 64 2 3 2 11/16 2/4 4 80 50 27 70 1.8 21/2 1½o 2151 6 4.4 65 24 73 2 2 1~o 2116 6.5 50 30 75 2.9 4 2/i 13,16 31/4 7.8 /00 65 30 19 3.5 3 11,16 31/8 1 80 27 79 3.2 5 4 F/to 3/io 10 25 /00 27 84 4.8 4 11/8 37/ 14 6 /00 29 87 6.3 ISO 5 i'll 3'/lo 16 125 29 90 1 8 6 1/i 3//8 29 200 ISO 32 98 /3 hex end JJ.I [.1 Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME-Bi 6.4 (except plugs 114 NPS - 12NPS (8 - 300 DN), are included in the "List of and bushings, ASME B16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW-P-501 (except plugs and bushings the Underwriters' Laboratories, Inc. WW-P-471). NOTE: Seethe Technical Data section for pressure-temperature ratings. See AnvilStar Web site for the most current lListings and approvals. Project: Date: -77 Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, 4' '9r REV. 03.03.06-0011 go to www.anvilstar.com or contact your local AnvilStar representative ...,.,,_..Lao. 900 Elbow - Straight AN1LBtarm Fire Products Division o1AflviIinternational ANYRIL Cast Iron Threaded Fittings Class 125 (Standard) Submittal Sheet APPROVED For Listing / Approval details contact your AnviiStar°" Representative. $j T Weight Size A block gain. in U./mm hIPS/ON in/mm lbs/kg lbs/kg 1/4 ½ 13/16 016 0.11 8 13 22 0.97 2.08 1Ao 0.25 0.26 10 14 24 011 812 1/2 11/16 11/8 0.4 0.41 IS 17 29 9.18 0.19 3/4 0.6 0.61 20 22 33 0.27 0.28 15/16. 11/2 0.92 0.95 25 24 38 0.42 0.43 11/4 1118 13/4 1.4 1.5 32 29 44 0.65 0.66 ½ 1/I6 11/16 2 2 40 33 49 0.88 0.91 2 1'16 21/4 3.1 3.2 50 40 57 1.4 15 21/2 113/16 211/16 4.9 5.1 65 41 68 2.2 7.3 3 23/11c 31/8 7.2 1.4 80 56 79 3.3 3.4 4 2/I6 3l3/4 12 13 00 68 98 5.5 5.7 5 35/ 4½ 21 - 125 84 114 10 6 31/8 51/4 31 33 158 90 130 14 15 O 53/16 69/116 65 61 200 ' 132 167 29 30 [' Anvil standard and extra heavy cast iron threaded fittings are Anvil standard and extra heavy fittings in this section, sizes manufactured in accordance with ASME-1316.4 (except plugs 1/4 NPS - 1 2NPS (8 - 300 DN), are included in the "List of and bushings, ASME B 16.14). Dimensions also conform to Inspected Fire Protection Equipment and Materials" issued by Federal Specifications, WW-P-501 (except plugs and bushings the Underwriters' Laboratories, Inc. WW-P-471). NOTE: Seethe Technical Data section for pressure-temperature ratings. See AnvilStor Web site for the most current Ustings and approvals. 7o.Engineer: Phone: rcec Contractor: Address: Notes 1: Notes 2: Anvil Cast & Malleable Iron Fittings For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REv. 03.03.06.001 go to www.anvilstar.com or contact your local AnvilStar representative Branch Outlet ANik.Star Fire Products Division of AnAlo International (ANYH Submittal Sheet The Gruvlok Fig. 7044 Branch Outlet is for direct connection of sprinkler heads and drop nipples. Just cut a hole, saddle up and fasten it with the U-bolt. The branch outlet provides an economical, quick, and easy outlet at any location along a pipe. Specially engineered to conform to the pipe O.D., the Fig. 7044 provides a leak tight reliable seal in both positive pressure and vacuum conditions. Ductile iron housings with Grade E gasket and carbon steel U-bolt (3/8e dia.) with Flanged nuts. Ductile iron housings is available black. The maximum working pressure for all sizes is 175 PSI (12.1 bar). APPROVED For Listing I Approval details contact your AnvilStarTM Representative. I MATERIAL SPECIFICATIONS:. HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12. U-BOLT & NUTS: Plated U-bolt conforming to ASTM A-307 with plated hex nuts conforming to ASTM A-563. COATINGS: Li Plain IJ Other (Specify): For other Coaling requirements contact an AnvilStar Representative. LUBRICATION: J Standard Gruvlok Gruvlok XtremeTM (Recommended for dry pipe systems and Freezer applications.) Ii Other (Specify): GASKETS: Materials Properties as designated in accordance with ASTM D-2000 11 Grade "E° EPDM (Green color code) 40°F to 150°F (Service Temperature Range) (-40°C to 66°C) Recommended for water service, diluted acids, alkalies solutions, salts, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. Other I,PROJECT lIlINFORMATION: II Project: Date: Phone: Architect I Engineer: Contractor: Address: Notes 1: Notes 2: PAGE 1 01 Gruvlok Couplings, Fittings, Flanges, Clamps For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV. 03.03.06-0016 go to www.anvilstar.com or contact your local AnvitStar representative Branch Outlet ANV1i..Star Firc Products Division of Anuflo lotcrosfisusl (A!. Submittal Sheet Mm. Din. Max. Die. A C Take-out Wt.Ea. Hole Diameter Dimensions 7R.-Lbs.IN-M Nanilnel Size Pipe O.D. Max. Pressure Working InJDW(mm) In ./mm psi/bar In ./mm In ./mm In ./mm, In ./mm In1mm In ./min Lbs/Kg F/tx ½ 1.660x0.840 175 1%o 1 '/4 2'/16 3½ 21A2 1% 27 33 0.8 32x15 42.4x21.3 12.1 30 32 53 89 56 35 - 0.4 11/4 x1/4 1.660x9.050 115 1/i 1½ 2'A6 31/2 2/52 1% 27 33 0.8 32x 20 42.4x 26.7 12.1 30 37 53 89 56 35 0.4 11/i X I.660x 1.315 175 1%6 11/4 2%o 31A 27h2 1½ 27 33 0.9 32 25 42.4x 33.7 12.1 30 32 56 89 56 38 0.4 11/2 x½ 1.900x0.840 175 13/16 1/4 25/3 31b 27A2 i3i5 27 33 0.8 40x 15 48.3x21.3 12.1 30 32 55 89 56 35 - . 0.4 1½x3/t 1.900x1.050 175 13/16 11/4 21/32 31/7 2½2 1% 27 33 0.8 40020 48.3026.7 121 30 32 55 89 56 35 8.4 1½x1 1.900x1.315 175 13/16 11/4 23/32 31/t 23't2 11/7 27 33 0.9 40x25 48.3033.7 12.1 30 32 511 89 56 38 . 04 2x½ 2.375x0.840 175 13/6 1/4 21h 37A 21A2 1% 27 33 0.8 SOs 15 60.3x 21.3 12.1 30 32 64 98 56 42 8.4 2x % 2.375x1.050 175 1%o 11/4 2/1 3½ 27A2 1A 27 33 0.8 50x20 60.3x26.7 12.1 30 32 64 98 50 42 . . 0.4 2 x 1 2.315x1.315 175 13/t6 11/4 35,5 31/6 37/33 ]3/4 27 33 0.9 50u25 60.3x33.7 12.1 30 32 67 98 56 45 - . 0.4 21/2 x½ 2.875x0.840 175 1A6 11/ 211A6 43A 21A2 2 21 33 0.8 65x15 730c21.3 12.1 30 32 69 III 56 51 . . 0.4 21/2 x /i 2.875x1.050 1/5 1 3A 6 i/t 2A6 43,5 27/t2 2 27 33 0.9 65x20 73,0x26.7 12.1 30 32 69 III 56 51, . 0.4 21b x 2.8/5x1.315 175 13/it 1~ 2/16 4% 2½n 2½ 27 33 1.0 65x 25 73.0x 33.7 12.1 30 32 72 III 56 54 . . 0.5 Not for use in copper systems. § - For additional Bolt Torque information, see Technical Data suction. I A WARNINGj For dry pipe systems and freezer applications lubrication of the gasket is required, Gruviok® XtremeTM Lubricant is recommended. PAGE 2 OF 2 Gruvlok Couplings, Fittings, Flanges, Clamps For the latest UL/ULC Listed and FM Approved pressure ratings, versus pipe schedule, REV- 03.03.06-17 go to www.anvilstar.com or contact your local AnvilStar representative F~Ood E-9, tee i 1/4" 8001957 GST.750 1/4 8002957 GST 100 1/4 8003957 GST 200 1/4 8004957 GST 300 1/4" 8005925 GST 600 1/4x314 25 5.93 125 1I4x1 25 6.25 125 1/4x2 25 8.13 125 114x3 25 9,38 125 114x6 25 11.25 125 Approvis 3/8 8006957 GST .75 1/4 x 3/4 25 5.63 125 • 3/8"::8007957 GSTIO .. 1/4x1 .25 5:93 125 3/8 8008957 GST 20 114x2 25 7.50 125 3/8' 8009925 GST 25-380' 318x2-112 25 1156 125 3/8" 8010957 GST 30 1/4x3 25 8.75 125 .3/8 . :8011925 : .GST 40 114x4 25 10.00 . 125 3/8 8012925 GST 60 1/4x6 25 11.25 125 1/2" 8013925 GST2 114X2 25 8.75 125 1/2" 8014925 . ST2.5-380 .3!8X.2-112 25. 12.50 . 125 1/2" 8015925 GST3 114X3 25 13.13 125 1/2" 8016925 GST4 1I4X4 25 13.25 125 112 8017925 GST6 1/4X6 25 13.69 125 !pprovas Sire Decr1ptknS Qty (pL QE 1 4" 8024957 DSTR lOu 1/4-20X 1 . 25 7.81 125 1/4 . 8025957 DST 100 1/4-14X 1 25 . 6.56 125 1/4" . 8026957 DST 150 1/4-14X 1-1/2 25 6.88 125 1/40 . 8021957 DST 200 1/4-14 X 2 25 7.50 125 1/4" 8028957 DST 250 1/4-12 X 2-1/2 25 8.44 125 1/4 . 8029957 . DST 300 114-14X 3 25 906 125 114' 8030957 7EK 500 12-24 X 1-1/2 25 6.88 125 3/8" 8037957 DSTR 1-1/2" 12-24 X 1-1/2 25 7.75 125 8038957 DSTR 1" i/4-20X 1 25 7.1.9 125 3/8 8039957 DSTR 516 5/16-18X 1-1/4 25 7.06 125 3/8' 8040957 DST 10 .1/4-14X 1 25 5.94 125 3/8" 8041957 DST 15 1/4-14X 1-1/2 25 6.56 125 318" '8042957 DST 20 1/4-14X2 25 6.88 125 3/8" 8043957 DST 25 1/4-14X 2-1/2 25 7.81 125 3/8 804457 . DST 30 114-14.X3 .. :.5 .8.44:.125 3/8" 8045957 DST 516 5/16-18X1-1/4 25 7.50 125 3/8' 8046957 TEK 50 . 12-24 X 1-1/2 25 6.88 125 1/2" 8031925 DST 2.0 1/4-14X2 25 8.44 125 1/2' 8032925 JST.2.5 1/4-14 X 2-1/2 . 25 9.06 125. 1/2" 8033925 DSTR 1.0 1/4-20X 1 25 6.25 125 112" 8034925 DSTR 5.16 5116-18X1-114 25 10.00 125 1/2" 8035925 DST 5.16 5/16-18X 1-1/4 25 8.44 125 1/2" 8036925 •• TEK 5.0 • 12-24 X 1-1/2 • 25 7.50 125 onerete rApprovals .XWt Part ModeI Size De (per y , .1/4" 8058957 CST 200 5/16x1-3/4 25 8.44 • 125 .3/8' 8059957 CST 20 • '5/16X1-3/4 • 25 7.81 125 .. . 112' 806095 'CST2 5116X 1-3/4 25 125 Nut Driver Use #14 Nut Driver for Sammys and Swivel Head Part If 8113910 Item #100 1S,-j- EWINDHE RS Nut Driver Use #I4SW Nut Diiver for Sidewnders and 1/21 Rod Sarnmys Part # 8114910 Item # 101 i!fL 1/4" 8018957 L !L SWG 100 1/4X1 25 9.38 125 1/4" 801957 .•SWG200 114X2 . 25 10.00 . 125 318' 8020957 SWG 10 1/4 X 1 25 7.50 125 3/8" 802197 •. SWG .......1/4X2 25 . . 875 . 125 318' 8022925 SWG 25-380 3/8 X 2-1/2 25 12.81 125 318" 8023925 SWG 30 . 1/4 X 3 25 10.63 125 - IF Módei 3/8" 8050957 SWD 10 114-14X 1 25 7.50 125 3/8" ..851957 SWD 15 114-14X 1-1/2 25 938 125 3/8" 8052957 SWD 20 1/4-14X2 25 8.13 125 3/8' 8053957 SWD 518 5116-18X 1-1/4 .. ....8.75 . 125 3/8" 8054957 SWDR 1-1/2" 114-20X 1-1/2 25 9.06 125 3/8" 8055957 SWDR1" . 1I4-20X 1 25 8.75 125 3/8" 8056957 SWDR 516 5/16-18X 1-1/4 25 10.31 125 r'-"-------..'—i"--t---- 3/8" : 1§057967 SWT 15 12-24X 1-1/2 25 .7.81 125 Wood Stee l - two screw ox Weight . GaS .. . Approvals Se Paft# Model Descriptions Qty (per 125) Qty C oncrete 1/4' 8062957 SWC 200 .5/16 X 13/4 25 938 125 8061957 . SWC2O . 5fl6Xi3/4.......... 25 .. .938,125 Screw Box Weight Case. Sammy Swivel Head Approvals Part #.. Model Descriptions Qty. (per 125) Qty Li 2!L \ • For 3/8" Rod PN-8139957 SH-GST2O 114x2 25 9.38 125 . U.S, Patent No. • 17° deflection from vertical 8140957 SH-GST22SS 114x2 25 9.38 125 \, 6,443,680 814195.7 SH-GST3O ••/4X3 25 10.94 125 .. Accommodates up to 8142957 SH-GST3OSS 1/4x 3 25 10.94 125 3-1/2 x 12 pitch roof I • Also available in stainless steel '?' :8137957. SH-DSTR 1 1/4-20 x 25 9.38 125 • Use #14 Nut Driver (black) 8138957 SH-DSTR 1-SS 1/4-20x1 25 9.38 125 -ThreadedR ore ctlY 4aflc1 .flGaugeM0 Steel Rod Screw Box. Weight Case from Approvals Part # Model Ga. Size Descriptions Q'. (per 126) Qy. r --'"---"r---"- 1OJL Q'.............. 22-20 8150922 3/8" XP 20 SammyX-Press20 25 10.3 125 . \ . . . 1/4-20x1-1/8 . 4 \ 1816 8153922 3/8 XP 35. SammyXPress35 25 103 125 1/4-20 x 1-1/8 Uninstalled 22-18 8181922 1/4" XP 200 Sammy X-Press 200 25 10.3 125 r \ 8151910 XPIT Sammy x Press It 1 1 02 1 Installation Tool CAMM Installed . . . (Kit Includes: Sleeve, Bit Receiver, Hex Wrench, and 25/64" Drill Bit) nRESSe 8152910 - XPDB 25/64" Drill Bit 1 0.14 1 Patent Pending FXTEX5098 - Hangers, Pipe Page 1 of UL Online Certifications Directory VFXT EX5098 Hangers, Pipe agbott9m Hangers,. Pipe -ee- eneral Information for-hangers—Pipe 1W BIJILDEX 349 W BRYN MAWR AVE rASCA, XL 60143 USA :andard pipe hangers: Self-drilling anchors for horizontal installation into steel. EX5098 Model Min Steel Thkns In. Rod Size In. Max Pipe Size In. SWDR 0.037 3/8 4 SWDR 516 0.037 3/8 4 :andard pipe hangers: Self-drilling anchors for vertical installation into steel. Model Min Steel Thkns In Rod Size In. Max Pipe Size In. DSTR 1 0.035 3/8 4 DSTR 1-1/2 0.035 3/8 4 DST516 0,188 3/8 4 DSTR516 0.037 3/8 4 SH-DSTR-1 0.035 3/8 4 SH-DSTR-1-SS 0.035 3/8 4 TEK-50 0.250 3/8 4 jecial pipe hangers: Threaded anchors for vertical installation into steel. Model Min Steel Thkns In. Rod Size In. Max Pipe Size In. X-Press 20 0.027 3/8 2 X-Press 35 0.043 3/8 3-1/2 tip ://database .ul.com/cgi-bin/XY V/template/L1SEXT/ I FRAME/showpage.html?name=VFXT.EX5098&ccns... 7/14/0 TXT.EX5098 - Hangers, Pipe Page 2 of :andard pipe hangers: Self-threading anchor for horizontal installation into the side of a wood timber or joist. Model Min Wood Thkns In. Rod Size In. Max Pipe Size In. SWG25 380 1-1/2 3/8 4 ecia1 pipe hangers: Self-threading anchor for horizontal installation into the side of a wood timber or joist. Model Min Wood Thkns In. Rod Size In. Max Pipe Size In. SWG20 1-1/2 3/8 3 SWG20-SS 1-1/2 3/8 3-1/2 ecial pipe hangers: Self-threading anchor for horizontal installation into the top chord or flange of a structural composite wood joist of minimum 1-1/2 / 1-1/2 in. size. Model Min Wood Thkns In. Rod Size In. Max Pipe Size In. SWG20 1-1/2 3/8 2-1/2 SWG20-SS 1-1/2 3/8 2-1/2 SWG25-380 1-1/2 3/8 3-1/2 :andard pipe hangers: Self-threading anchor for vertical installation into the bottom of a wood timber or joist. Model Min Wood Thkns In. Rod Size In. Max Pipe Size In. GST 25-380 1-1/2 3/8 4 GST 30 1-1/2 3/8 4 GST 30-SS 1-1/2 3/8 4 SH-GST30 1-1/2 3/8 4 SH-GST30-SS 1-1/2 3/8 4 Decial pipe hangers: Self-threading anchor for vertical installation into the bottom of a wood timber or joist. Model Min Wood Thkns In. Rod Size In. Max Pipe Size In. GST 20 1-1/2 3/8 2-1/2 GST 20-SS 1-1/2 3/8 2-1/2 SH-GST20 1-1/2 3/8 3 SH-GST20-SS 1-1/2 3/8 3 ftp ://database.ul.com/cgi-bin/XY V/template/LISEXT/ I FRAME/showpage.html?nameVFXT.EX5098&ccns... 7/14/0 FXTEX5 098 - Hangers, Pipe Page 3 of :andard pipe hangers: Self-threading anchor for vertical installation into the bottom chord or flange of a structural composite wood joist of minimum 1- 12 by 1-1/2 in. size. Model Min Wood Thkns In. Rod Size In. Max Pipe Size In. GST 25-380 1-1/2 3/8 4 Decial pipe hangers: Self-threading anchor for vertical installation into the bottom chord or flange of a structural composite wood joist of minimum 1-1/2 t 1-1/2 in. size. Model Min Wood Thkns In. Rod Size In. Max Pipe Size In. GST 20 1-1/2 3/8 2-1/2 GST 20-SS 1-1/2 3/8 2-1/2 aU.!patesi on 2004-08-27 esti Notice of Copyright jOc 2006 Underwriters Laboratories Inc.( ie appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's )llow-Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow-Up Service. Always look for ie Mark on the product. L permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, esigns and/or Listings (files) must be presented in their entirety and in a non-misleading manner, without any manipulation of the data (or drawings). 2 e statement "Reprinted from the Online Certifications Directory with permission from Underwriters Laboratories Inc." must appear adjacent to the (tracted material. In addition, the reprinted material must include a copyright notice in the following format: "Copyright © 2006 Underwriters boratories Inc®" An ndpenOnn organization woK'ng for a sale, notid witfl integr n n n n ity. preciio ad irorn g iedo. (1-2zi,w ttp ://database.ul.com/cgi-bin/XY V/template/LISEXT/ 1 FRAME/showpage.html?nameVFXT.EX5098&ccns... 7/14/0 40.60 1 V3369 usreD Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent V3605 STANDARD RESPONSE ~4 N V3606 QUICK RESPONSE k 4_2 f 4 FLUSH SLEEVE--ARP— PLAIN BARREL INTERMEDIATE EXTENDED RECESSED -'SKIRT 1. The Model V36 Series Dry Type Pendent and Recessed Pendent Sprinklers have been redesigned utilizing stainless steel internal components. The V36 Dry Sprinkler is used in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Model V3606 and V3605 Intermediate Level Pendent sprinklers incorporate a water shield plate to prevent water from higher level sprinklers from interfering with normal operation. These intermedi- ate level sprinklers are designed for use in intermediate levels of rack storage or other open grate storage arrangements where [hey may be exposed to upper level or ceiling level sprinklers. Available in either standard or quick response versions, the Model V36 Dry Type Pendent Sprinkler utilizes a frangible glass bulb. At the bulb's rated temperature, the sprinkler opens releasing the bulb seat assembly, causing the inner tube assembly to move, allowing the spring assembly to pivot along- side the inner tube. Al this time, water flows through [lie sprinkler and is distributed by the deflector, in an approved discharge pattern. The heart of the Model V36 sprinkler's proven actuating assembly Is a hermetically sealed frangible glass bulb that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. Al the prescribed temperature the internal pressure within the bulb exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. COVERAGE For coverage area and sprinkler placement, refer to NFPA 13 standards. NOTE: These sprinklers meet the new test requirements in UL 199, effective March 26, 2004. JOB OWNER CONTRACTOR ENGINEER System No Submitted By Spec Sect- Para Location Date Approved Date www.victaulic.com vICTAuLIc IS REGISTERED TRADEMARK OF VICTAULIC COMPANY. it) 2006 vicTAuLic COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV .G TECHNICAL SPECIFICATIONS: Exaggerated for clarity FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 4060 fl6 (5 P LISTED - Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent 4pt (F V3605 STANDARD RESPONSE I I i Ai '13606 QUICK RESPONSE V I IL11I IL I FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED SKIRT Models: V3606 and V3605 Style: Pendent. Recessed Pendent or Intermediate Level Pendent Nominal Orifice Size: W/13 mm Orifice Insert: Stainless steel per UNS S30300 K-Factor: 5.6 Imp./8.1 S.l.A Nominal Thread Size: 1 NPT/33.7 mm Max. Working Pressure: 175 psi/i 200 kPa Factory Hydrostatic Test: 100% © 500 psi/3450 kPa Mm. Operating Pressure: 7psi/48kPa Temperature Rating: See chart on page 2 MATERIAL SPECIFICATIONS Deflector: Brass per UNS C22000 or Stainless Steel per UNS S30400 Bulb: Glass with glycerin solution. Bulb Nominal Diameter: Standard: 5.0mm Quick Response: 3.0mm Split Spacer: Stainless steel per UNS S30300 Load Screw: Brass per UNS C36000 Pip Cap: Stainless steel per UNS S30300 Spring Seal Assembly: Teflon* coated Beryllium nickel alloy and stainless steel per UNS S30300 Frame: Die cast brass Outer Tube: Galvanized steel pipe Inner Tube: Stainless steel per UNS S30400 Escutcheon/Plate: 1010 - 1018 mild sleet and stainless steel Torsion Spring: SST Wire ACCESSORIES Installation Wrench: Model V36 Open End and Recessed Wrenches lit all V36 Series Frames. Sprinkler Finishes: Plain brass Chrome plated While painted t A Flat black painted J- Custom painted t A Wax Wax/Lead Lead Proprietary Nickel Tefton Coated For cabinets and other accessories refer to separate sheet. " For K-Factor when pressure is measured in Bar, multiply S.I. units by 10.0. * Teflon is a registered trademark of Dupont Co. t Not available on the Intermediate Level Style Pendent. Models V3606/V3605 are UL Listed For cor- rosion resistance in all configurations NOTE: Weather resistant escutcheon available upon request. www.victaulic.com VICTAUUC IS A REGISTERED TRADEMARK OF vicTAuLic COMPANY. C 2006 vICTAULIC COMPANY. ALL P101-ITS RESERVED. PRINTED IN THE USA. 40.60 2 'JcLico REV.-.G FIRE PROTECTION PRODUCTS --AUTOMATIC SPRINKLERS 40.60 I360 - V5 LISTED Dry Type Standard Spray Pendent, Inten-nediate Level Pendent & Recessed Pendent V3605 STANDARD RESPONSE V3606 QUICK RESPONSE IT1 A FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED SKIRT APPROVALS/LISTINGS vsoc Ow k Pendent , I5 200 I. 1155,200,286 1-15, 1-55,200, R( 13 8.1 5765,33141 57&3,u3,141 5705,93,1.1 55 2(X) YC 1 S 1A 00 C 93606 Quick Recessed Pendent V3605 5.6 ,. .,tai,dard 35, 55, 200,206:1S5,I55,200, 2i36 135, 155, 200,266 1$ 8.1 Pendent 7 9C( III 57,68 93, 1.11 '7 05 93,141 13Sj55,200,256. IS5H5S,2002601 135,155,200 V3605 Standard Recessed Pendent * Listings arid approval as of printing. /5 For K-Factor when pressure is measured in Bar, multiply S.I. units by 10 "Listed (or all hazards. -I Approved for V3605 and V3600 dry sprinklers up 10 48" length. RATINGS All glass bulbs are rated for temperatures from -67FI-55°C 10 those shown in (able below. Ordinary W 57 011 '48 Orerspe Ordinary 155 68 1011 38 Red Intermediate 200 93 150 65 Green lnterhediate 286 I'll 225 107 Blue www,victaul(c.com '-,"At— auhliff VICTAUUC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 02006 VICTAULIC COMPANY. ALL SIGHTS RESERVED. PRINTED IN THE USA. REV 6 40.60 ,3 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS i36, 56 Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent V3605 STANDARD RESPONSE V3606 QUICK RESPONSE FLUSH 40.60 LISTED I L SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED SKIRT ORDERING INFORMATION AVAILABLE WRENCHES Please specify the following when ordering Model V36 Open End and Recessed Wrenches Fit all V36 Series Frames. www.victaulic.com VICTAULIC IS REGISTERED TRADEMARK or VICTAULIC COMPANY. Y 2006 VIcTAULIC COMPANY. ALL P101116 RESERVED. PRINTED IN THE USA. A taulicr 40.60 4 --• REYG FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS 40.60 V36 56 fSTED Dry Type Standard Spray Pendent, Intermediate Level Pendent •II & Recessed Pendent I I P r7I V3605 STANDARD RESPONSE V3606 QUICK RESPONSE A. FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED SKIRT WARNING Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. Painting, plating, or any re-coating of sprinklers (other than that sup- plied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. O The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have addi- tional maintenance, testing, and inspection requirements that must be followed. LJ If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters: P.O. Box 31, Easton, Pennsylvania 18044-0031 USA, Telephone: 001-610-559-3300. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 62006 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE LISA. REV .G 40.605 40.60 LISTED Al (LII PLAIN BARREL INTERMEDIATE EXTENDED RECESSED FIRE PROTECTION PRODUCTS - AUTOMATIC SPRINKLERS V36, K56 Dry Type Standard Spray Pendent, Intermediate Level Pendent NFA & Recessed Pendent V3605 STANDARD RESPONSE V3606 QUICK RESPONSE L . FLUSH SLEEVE AND SKIRT DIMENSIONS NOTE: The 'A" dimension of a dry sprinkler which extends into freezers From wet pipe systems should he sized to provide at least 14 between the Freezer's outside wall or ceiling and the wet pipe. ------fl Tee with same outlet size r as sprinkler thread size. Seeimportant installation Information, No.2 - -- Th 1'NPT (Ml m. 1W) Flush - - Tee with same outlet size as sprinkler thread size. H7\ I I See lmpcmrtarst Installation Information. Nri 2 PT (Min. 1½")) 3Da-1 ___ Intermediate Level Pendent Tee with same outlet Cite sprinkler thread size. Seeirnportastlnslallation -- lnformation No.2 - 1 NPT (MEn. 1W) i 1WMln.Dla. ' Hole in ceiling / / 3½J L J 3W Mm. Two Piece Mae. Escutcheon 1 Extended fl-------fl Tee with same outlet size 1— as sprinkler thread size. -- See important Instoiritlor Information', Ncr. 2 I 1' NPT • (Min. 114') -•( 1W Mm. Dia. l-kmle in ceiling r Two Piece T Escutcheon - 2W Mm. 4' Man. (-3t' DEs. —.1 Sleeve and Skirt Tee with same outlet size as sprinkler thread size. / See important installation -- Information", No. 2 PT wr (Mm. 1W) Plain Barrel -- -fl Tee with same outlet size lb as sprinkler thread size. See important Installation - - Infrjamstion Na 2 ,1, '- PT (Min. 1t4i Collar 2 Mm. iDma. I Hole in Ceiling Ceiling Cup _/j , Recessed www.victaulic.com VlcTAUUC is A REGISTERED TRADEMARK or VICTAULIC COMPANY. 05 2006 ViCTAUL1C COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. Xktauliliff 40,60.6 REV...G FIRE PROTECTION! PRODUCTS - AUTOMATIC SPRINKLERS 36 K56 LISTED Dry Type Standard Spray Pendent, Intermediate Level Pendent 1 011 41 ' I & Recessed Pendent V3605 STANDARD V3606 QUICK RESPONSE ... '"M RESPONSE Aflli; ii ILTk I FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED SKIRT DISTRIBUTION PATTERNS MODELS V3606 V3605 PENDENT, RECESSED PENDENT & INTERMEDIATE LEVEL PENDENT DISTRIBUTION PATTERNS -TRAJECTORY 2 4' 6' 8' 10' 12 14' 0.6m 1.2m 1.8m 2.4m 3.0m 3.7m 4.3m 7psi -..-' 15 psi 30ps1 48 kPa 103 kPa 207 kPa NOTES: 1 Data shown is approximate and can vary due to differences in installation. 2 These graphs illustrate approximate trajectories, Floor-wetting, and watt-wetting patterns For these specific Victaulic FireLock automatic sprinklers. They are provided as information For guidance in avoiding obstructions to sprinklers and should not be used as minimum sprin- kler spacing rules For installation. Refer to the appropriate NFPA National Fire Code and the Authority Having Jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to Follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings, Approvals and Warranties. 3 All patterns are symmetrical to the centerline of the waterway. www.victaulic.com xzc_tz~u I ii C~ VICTAULIC IS REGISTERED TRADEMARK or vICTAuLIC COMPANY. SI 2005' VIcTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. REV G 40.60.7 8' 2.4 m 6' 1.8 m 4, 1.2 m 2' 0.6 m 0 LX1 V36, K56 LISTED Dry Type Standard Spray Pendent, Intermediate Level Pendent & Recessed Pendent j I V3605 STANDARD RESPONSE • . I V3GOG QUICK RESPONSE ' 1 FLUSH SLEEVE AND PLAIN BARREL INTERMEDIATE EXTENDED RECESSED SKIRT IMPORTANT INSTALLATION INFORMATION For detailed installation instructions, see publication 1-40. No. 1 Victaulic Model V36 Series Dry sprinklers should be installed in accordance with NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible, the proper sprinkler wrench may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. No. 2 Dry sprinklers MUST be Installed only into the outlet of a cast or malleable iron tee. No. 3 DO NOT install dry sprinklers into any couplings or threaded elbows. In addition, DO NOT install dry sprinklers into any lilting that interferes with thread penetration. NOTE: The end seal of the dry sprinkler MUST NOT bottom out in the tilling. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Viclaulic or to Viclaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. US & INORLD HEADQUARTERS CANADA CENTRAL AND SOUTH AMERICA P.O. Box 31 905-884-7444 1-610-559-3300 Easton, PA 18044-0031 USA 905-884-9774 (fax) 1-610-559-3608 (fax) viccanada@victaulic.com vicaIvictauliccom 4901 Kesslersville Road Easton, PA 18040 USA LIJIIOPE ASIA PACIFIC 1-800-PIC<-VlC (1-800-142-5842) 32-9-381-15-00 86-21-54253300 1-610-559-3300 32-9-380-44-38 (fax) 96-21-54253671 (fax) 1-610-250-8817 (fax) viceuro©victaulic.be vicap@victaulic.com pickvicvictauIic.com UNITED KINGDOM MIDDLE EAST www.victauhc.com 44 (0) 1438741100 971-4-883-88-70 II liii Ifflll IIIII II III ilhilU 44 (0) 1438313883 (fax) 971-4-883-88-60 (fax) WCAS-6N6TCS viceuro@victaulic.be UPDATED 4/2006 40.60 3123 REV C ulid VICTAULIC IS REGISTERED TRADEMARK or VICTAULIC COMPANY. 2006 VICTAULIC COMPANY. ALL P101-ITS RESERVED. PRINTED IN THE USA. 40.60