Loading...
HomeMy WebLinkAbout2675 GATEWAY RD; ; FA080008; Permit8/17/22, 11:23 AM FA080008 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2675 GATEWAY RD Permit Type: FALARM Parcel No: Lot #: 0 Permit No: FA080008 Status: ISSUED Applied 1/7/2008 Approved: 1/8/2008 Reference No.: Issued: 1/8/2008 PC #: Inspector: Project Title: BRESSI RANCH VILL.CTR - BLDG F 2 FIRE ALARM INSPECTIONS @ $65/EA Applicant: Owner: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 PLANS ARE LOCATED IN: 2629 GATEWAY RD, BLDG C fA(DJbDoS MENIALS OF FIRE ALARM SYSTEMS 4 'P FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: Rressi Ranch Villane-Rido Shop F Address: 2675 Gateway Rd Representative of protected property (name/phone): Authority having jurisdiction: Carlsbad Fire Department Address/telephone number: 760-602-4660 Organization name/phone Representative name/phone Installer JJJ Enterprises Supplier DMP Service organization JJJ Enterprises Location of record (as-built) drawings: Owner Location of operation and maintenance manuals: Owner Location of test reports: Owner -- A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): By others Effective date: Expiration date: System Software Operating system (executive) software revision level(s): Ver. 3.0 Site-specific software revision date: N/A Revision completed by: DMP (name) (firm) 1. Type(s) of System or Service NFPA 72, Chapter 6— Local If alai-in is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8 - Remote Station Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: fl NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8 - Central Station Prime contractor: Central station location: (NFPA 72, 1 of 4) FIGURE 4.5.2.1 Record of Completion. 2002 Edition 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: El McCulloh El Multiplex El One-way radio El Digital alarm communicator El Two-way radio El Others Means of transmission of alarms to the public fire service communications center: System location: El NFPA 72, Chapter 9— AuxilIary Indicate type of connection: El Local energy El Shunt El Parallel telephone Location of telephone number for receipt of signals: Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by Vinnie Bruzzi on 11/18/2008 _,includes the devices shown in and 6, and has been in service since 11/18/2008 ZNFPA 72, Chapters 0 07 8 9 Ii (circle all that apply) Z NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions El Other Signed:" ,•'_:; ,,- ,_K _.- -' Date: 11/18/2008 Oreani " iii Ees ( Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached All operational features and functions of this system were tested by Vinnie Bruzzi and found to be operating properly in accordance with the requirements of: ZNFPA 72, Chapters 8 9 & II (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions El Other date 11/18/2008 Signed: Date: 11/18/2008 Organizatioi5 ' JJJ Signaling Lin.efrcuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: N/A Style: Class: (NFPA 72, 2 of 4) FIGURE 4.5.2.1 Continued 2002Edition ] FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 5. Alarm-Initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: I Style: 4 Class: MANUAL Manual stations Noneoded 1 Transmitters Coded N/A Addressable Combination manual fire alarm and guard's tour coded stations N/A AUTOMATIC Coverage: Complete Partial Selective X Nonrequired Smoke detectors I Ion Photo I Addressable Duct detectors N/A Ion Photo Addressable Heat detectors N/A FT RR FT/RR RC Addressable Sprinkler waterfiow indicators: Transmitters Noncoded I Coded Addressable The alarm verification feature is disabled N/A or enabled , changed from seconds to seconds. (1') Other (list): N/A 6. Supervisory Signal-Initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR El Coded stations Noncoded stations El Compulsory guard's tour system comprised of transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. SPRINKLER SYSTEM Check if provided Valve supervisory switches El Building temperature points El Site water temperature points El Site water supply level points Electric fire pump: __ Fire pump power .D_Fire pump running El Phase reversal Engine-driven fire pump: (Ii) El Selector in auto position El Engine or control panel trouble El Fire pump running ENGINE-DRIVEN GENERATOR: El Selector in auto position El Control panel trouble El Transfer switches = Engine running Other supervisory function(s) (specify): N/A (NFPA 72, 3 of 4) FIGURE 4.5.2.1 Continued 2002Edition 72-34 NATIONAL FIRE ALARM CODE Annunciator(s) Number: N/A Type: Location: Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: N/A Single:Multiple: Quantity of speakers installed: N/A Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: N/A Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: 1 Style: Y Class: B Types and quantities of notification appliances installed Bells N/A With Visible Speakers N/A With Visible Horns I With Visible 1 Chimes N/A With Visible Other: N/A With Visible (D Visible appliances without audible: N/A 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: I20VAC Current rating: 3.0 Amps Overcurrent protection: Type: Breaker Current rating: 20 amp.. Location: Electric Room Secondary (standby): Storage battery: 2 7ah in series Amp-hour rating: 14 Calculated capacity to drive system, in hours: 24 Engine-driven generator dedicated to fire alarm system: n/a Location of fuel storage: n/a Emergency system used as backup to primary power supply: n/a Emergency system described in NFPA 70, Article 700: n/a 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): N/A System deviations from the referenced NFPA standard(s) are: No deviations Upon Ompletion of the system(s)jttisfactory test(s) witnessed (if required by the authority having jurisdiction): oihoriy having jurisdiction / (title) (NFPA 72, 4 of 4) FIGURE 4.5.2.1 Continued 2002Edition