HomeMy WebLinkAbout438 TAMARACK AVE; ; FPR2019-0113; Permitof I 1 iiP4l 1E1 iI4I C21iisAwgid Fifrie1Pe)jn)iit - __ ___0 -0 Print Date: 08/16/2022 Permit No: FPR2019-0113 Job Address: 438 TAMARACK AVE, CARLSBAD, CA 92008-4127 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Underground Fire Parcel #: 2042804503 Track 4*: Applied: 05/16/2019 Valuation: $0.00 Lot 4*: Issued: 08/13/2019 Occupancy Group: Project 4*: Finaled Close Out: 09/25/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Salcedo, Felix Plan Check 4*: Project Title: Description: TAMARACK BEACH HOMES - UNDERGROUND PLANS F PContra cto r: CODER CONSTRUCTION INC -INACTIVE 332132ND ST SAN DIEGO, CA 92104-4737 (619) 770-9408 FEE AMOUNT FIRE Underground Piping with up to 4 Hyds/Risers $756.00 Total Fees: $756.00 Total Payments To Date: $756.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov ZI?N UvR odsO 805Q)=VFQ)& WILKIMS Double Check Detector Assembly Application Designed for installation on water lines in fire protection sys- tems to protect against both backsiphonage and backpressure of polluted water into the potable water supply. A test cock plug is provided to protect against fouling caused by insects, dirt and debris. Assembly shall provide protection where a potential non-health hazard exists. Standards Compliance UL® Classified (horizontal & vertical) C-UL® Classified (horizontal & vertical) ASSE listed 1048 (horizontal & vertical) Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California (horizontal & vertical) By-Pass Backf low Assembly 3/4" Model 350D Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA approved) Buna Nitrile (FDA approved) Polymers NorylTM, NSF Listed Springs Stainless steel, 300 series Test cock cover Plastic Options (Suffixes can be combined) El - with OS & Y gate valves (standard) El LM - less water meter 0 - with gal meter (standard) 0 CFM - with cu ft meter Accessories O Repair kit (rubber only) El 05 & Y Gate valve tamper switch (OSY-40) 0 QT-SET Quick Test Fitting Set Features Sizes: 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections (Threaded) ANSI 131.20.1 I-' Dimensions & Weights (do not include pkg.) MODEL SIZE DIMENSIONS (approximate) WEIGHT D D A B C F OS&Y OPEN OS&Y CLOSED in. I mm in. mm in. mm in. mm in. I mm in. mm in. I mm lbs. I kg 2 50 231/4 591 9 j 229 9 229 13 330 11 330 13/4 44 65 29.5 Zurn Industries, LLC I Wilkins 1747 commerce way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. B Date: 6/17 Document No. BF-950XLTDA Product No. Model 950XLTDA Pagel of2 /7 Flow Characteristics Rated Flow (established by approval agencies) MODEL 950XLTDA 2" (STANDARD & METRIC) FLOW RATE (Ifs) 0.0 3.2 6.3 9.5 12.6 15.8 138 CL '55 103 0 50 100 150 200 n 25 FLOW RATE (GPM) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturer's instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. OUTDOOR INSTALLATION VERTICAL INSTALLATION Specifications The Double Check Detector Backflow Prevention Assembly shall be ASSE Listed 1048, and supplied with full port gate valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be SILICONE. The first and second check shall be located at a 450 angle and ac- cessible for maintenance from the top of the device, without removing the device from the line. Each check shall have sepa- rate access covers and test cocks shall be accessible from the top of the device. Test cocks shall be protected from debris by a plug. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 950XLTDA. Zurn Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1 L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2