Loading...
HomeMy WebLinkAbout1808 ASTON AVE; 240; FPC2018-0364; PermitCity of jiI1l:il Carlsbad Print Date: 09/14/2022 Permit No: FPC2018-0364 Job Address: 1808 ASTON AVE. #240, CARLSBAD, CA 92008-7365 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2121200700 Track #: Applied: 11/06/2018 Valuation: $161,529.23 Lot #: Issued: 11/27/2018 Occupancy Group: Project #: Finaled Close Out: 11/22/2019 #f Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Fieri, Dominic Plan Check 4*: Salcedo, Felix Project Title: Description: SPEC SUITE -SPRINKLER TI (46 HEADS) Applicant: FPContractor: TOTAL FIRE PROTECTION INC TOTAL FIRE PROTECTION INC JOHN CAPUTO 1611 S MELROSE PL, 4* 244 1611A S MELROSE DR VISTA, CA 92081-5471 VISTA, CA 92081-5407 (760) 525-4329 (760) 525-4329 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov r Q c CD TFIR CD . N — I :; Co 0 0 C1 Lu C-) (0 MATERIAL DATA SUBMITTAL UL wa coO 5 Speculative Suite 240 1808 Aston Avenue C4 5 Carlsbad, CA 92008 Q co 0D _ u. age * 1-2 3-10 11-12 13-20 21 22 23 24 25-33 [I: Mechanical Tee Sprinkler Hanger Hanger Hanger Hanger Attachment Manufacturer Allied Dyna-Thread Pipe Tyco Ductile Iron Fittings Tyco Fig 40-5 Strap Tee Reliable F 1 FR56 Sprinkler Afcon Fig. 100 Beam Clamp Afcon Fig. 162 Retaining Strap Afcon Fig. 300 Ring Hanger Afcon Fig 655 All Thread Rod Powers Snake+ Internally Threaded Screw Anchor Total Fire Protection, Inc. 1611 A S. Melrose Dr. *244 Vista, CA 92081 (760)525-4329 fax (877) 724-4329 C16-955387 tfpjohnc©gmail.com DynawThreado Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of Sch40 with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch40 pipe with quality and superior hydraulic advantages. S S Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. (P <~> @ Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA- 13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). rTSpecifications NPS Nominal I.D. WI. WI. (H20 Filled) Pc Wt/Uft (21') WtI1.lft (24') Wtfl.Ift (251 In; mm In; mm Lbs/Fl; Kg/rn Lbs/F(; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 1056 11/4' 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 2519 40 41.6 3.4 4.79 44 959 1097 114 2 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103, tqco/Flowconttol 16100 S. Lathrop . Harvey, IL 60426 ()died 11350 Norcom Rd. . Philadelphia, PA 19154 TUBE & CONDUIT 2525 N. 27 th Ave. • Phoenix, AZ 85009 Customer Service: 1 (800) 882-5543 Fax 708-339-1806 S3-3 Submittal Data Sheet Dyna-Thread® Full Line Sch-40 Replacement Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industry. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Threads inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. Also, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna-Thread and Sch-40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00; Comparison to L.W.T. Pipe More wall thickness at the thread (CRR=1 .00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 11. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on than many zinc- coated lightwall threadable pipe products. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Stamp Here . Specifications & Approvals Super 40/ Dyna-Thread pipe is manufactured to meet: ASTM A 135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna-Thread are rated at 300 psi working pressure. Super 40/ Dyna- Thread is UL and ULC Listed for wet, dry and pre-action sprinkler systems and FM Approved for use in wet systems. Super 40fDyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40/Dyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll- grooved, and plain-end fittings. (See listing information). The internal surface of all black Fire Sprinkler pipe up to 4.5000" in diameter shall be coated with Allied Tube & Conduit Antibacterial Formula "ABF". Specifications NPS Nominal I.D. WI. WI. (1120 Riled) Pcsl WI/lift (21') WI/Lift (24') WI/Lift (25') In; mm In; mm Lbs/Fl; Kg/rn Lbs/Fl; Kg/rn Lift Lbs; Kg Lbs; Kg Lbs, Kg 1' 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105el 1h/4 1.408 1.870 2.54 51 2002 2288 2384 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 251 40 41.6 3.4 4.79 44 959 1097 114 2" 2.104 3.050 4.57 30 1921 2196 228 50 53.4 4.5 6.80 30 871 996 103 American Tube and Pipe was acquired by Allied Tube and Conduit on February 1, 1997. The engineered lightwall and standard wall family of products although they have different names are the same in all respects with regard to strength, weight, bundle count, listings and approvals. For example, Dyna-Flow and Super Flo are the same product as are Dyna Thread and Super 40. XL is manufactured UO L II with Exterior galvanized coating. BLT is @ 9 manufactured with Black lacquer coating. Listed Approved Listed Project: Sprinkler Contractor: Date: Engineer: Specification Reference: System Type: Locations: Comments: S3-4 tqC0 /Fire & Building / Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Pipe Fittings NPT Threaded, Ductile Iron General Description The Tycoe Series 600 Threaded Pipe Fittings and California Tees & Elbows are manufactured from ductile iron. They are stronger and more corrosion resistant than cast iron fittings. The additional strength is provided by the ductile properties and by adding mag- nesium while the iron is being poured into the final cast shape. Although lighter than standard cast iron, the fit- tings have an added advantage of be- ing less susceptible to cracking due to their added strength. The Series 800, California, and Figure 719 Threaded Pipe Fittings are a re- designation for the Central Series 800, California, and Figure 719 Threaded Pipe Fittings. WARNINGS The Threaded Pipe Fittings described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Approvals: UL Listed and FM Approved Maximum Working Pressure: Series 800 and California Fittings 250 psi (17,2 bar) Figure 719 Plug: 250 psi (17,2 bar) Page 1 of 10 Material: Series 800 and California Fittings: Ductile Iron Figure 719 Plug: Cast Iron Pipe Thread: NPT per ANSI B1.20.1 Installation Apply Teflont tape or high quality pipe joint compound on male pipe threads and tighten two to three turns beyond hand tight. NOTE Installers who have not used ductile iron threaded fittings should be in- structed that the fittings are stron- ger than the pipe and overtightening the fitting can create leaks and cause damage to pipe threads. In general, there is about one-half turn difference between cast iron and ductile iron fit- tings. Apply Teflon tape or high qual- ity pipe joint compound on the male pipe threads and tighten two to three turns beyond hand tight. If an auto- matic make-on machine is being used, please exercise caution in setting the machine to the proper parameters pri- or to tightening fittings onto the male pipe threads. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warran- ty is given for products or components manufactured by companies not af- filiated by ownership with TFBP or for products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applicable JANUARY, 2008 Standards of the National Fire Protec- tion Association, and/or the standards of any other Authorities Having Juris- diction. Materials found by TFBP to be defective shall be either repaired or re- placed, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other ob- ligation in connection with the sale of products or parts of products. TFBP shall not be responsible for sprinkler system design errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made In lieu of any and all other warranties, ox- cress or implied, including warranties of merchantability and fitness for a carticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure When placing an order, indicate the full product name. Please specify the quantity, figure number, wall thickness, and size. registered trademark of E. I. du Pont de Nemours and Company or Its affiliates. TFPI7IO Page 2of 10 TFPI7I0 FIGURE 811 FIGURE 813 90° ELBOW 45° ELBOW TABLE 1 NOMINAL DIMENSIONS FIGURES 811 & 813 Figure 811 Approx. A B inches Weight Part Inches Inches (mm) Lbs. Number (mm) (mm) (kg) 0.56 0.24 86206 0.88 0.38 (14,2) (0,11) (22,4) (9,7) 0.75 0.40 86205 1.00 0.44 (19,0) (0,18) (25,4) (11,2) 0.81 0.64 86200 1.13 0.81 (20,6) (0,29) (28,7) (20,6) 1.06 0.95 86201 1.31 0.63 (26,9) (0,43) (33,3) (16,0) 1.19 1.24 86202 1.44 0.69 (30,2) (0,56) (36,6) (17,5) 1.50 1.74 86203 1.68 0.94 (38,1) (0,79) (42,7) (23,9) 1.56 3.28 1,94 1.00 0N65 (68,3) (39,6) (1,49) 86204 (49,3) (25,4) (1,22) 86782 Nominal Pipe Size Figure 813 ANSI A Approx. Inches Inches Weight Part ON (mm) Lbs. Number (kg) 1/2 1.13 0.22 86780 0N15 (28,7) (0,09) 3/4 1.31 0.33 86781 DN20 (33,3) (0,15) 1 1.50 0.48 86280 DN25 (38,1) (0,21) 1-1/4 1.75 0.73 86281 DN32 (44,5) (0,33) 1-1/2 1.94 0.93 86282 DN40 (49,3) (0,42) 2 2.25 1.55 86283 DN50 (57,1) (0,70) 2-1/2 2.69 2.70 0 TFPI7IO Page 3 of 10 FIGURE 812 90 REDUCING ELBOW Nominal Pipe Figure 812 Size ANSI A B C D Approx. Weight Part Inches Inches Inches Inches Inches Lbs. Number DN (mm) (mm) (mm) (mm) (kg) 314x112 1.19 1.19 0.63 0.63 0.33 86342 DN20 x 15 (30,2) (30,2) (16,0) (16,0) (0,15) 1 x 1/2 1.25 1.38 0.56 0.81 0.44 86210 0N25 x 15 (31,8) (35,1) (14,2) (20,6) (0,20) 1 x314 1.38 1.44 0.69 0.88 0.53 86211 DN25x20 (35.1) (36,6) (17,5) (22,4) (0,24) 1-1/4x112 1.31 1.50 0.63 0.94 0,64 86212 DN32 x 15 (33,3) (38,1) (16,0) (23,9) (0,29) 1-114x3/4 1.44 1.63 0.75 1.06 0.75 86213 DN32 x 20 (36,6) (41,4) (19,0) (26,9) (0,34) 1-114x1 1.56 1.68 0.88 1.00 0.77 86214 DN32 x 25 (39,6) (42,7) (22,4 (25,4) (0,35) 1-1/2 x 3/4 1.50 1.75 0.75 1.19 0.95 86221 DN40x20 (38,1) (44,4) (19,0) (30,2) (0,43) 1-1/2 X 1 1.63 1.81 0.88 1.13 0.99 86215 DN40x25 (41,4) (46,0) (22,4) (28,7) (0,45) 1-112x1-1/4 1.81 1.88 1.13 1.19 1.14 86216 DN40x32 (46,0) (47,8) (28,7) (30,2) (0,52) 2x314 1.63 1.94 0.88 1.38 1.39 86217 DN50x 20 (41,4) (49,3) (22,4) (35,1) (0,63) 2x1 1.75 2.06 2.00 1.31 1.58 86218 DN50x25 (44,4) (52,3) (50,8) (33,3) (0,72) 2 x 1-1/2 2.00 2.19 1.25 1.44 1.67 86220 DN50x40 (50,8) (55,6) (31,8) (36,6) (0,76) 2-1/2 x 2 2.38 2.63 1.25 1.88 3.01 86262 DN65x50 (60,5) (66,8) (31,8) (47,8) (1,36) TABLE 2 NOMINAL DIMENSIONS FIGURE 812 01 0 TFPI7I0 Page 5of 10 0 Nominal Pipe Size ANSI Inches ON Part Number 1/2 72779 DN15 3/4 72778 DN20 ______ 1 72755 0N25 1-1/4 72754 0N32 1-1/2 72753 0N40 2 72752 Dt450 2-1/2 72758 DN65 1 -fl _ Ujit FIGURE 814 FIGURE 818 IRON TEE STRAIGHT COUPLING 1.63 TABLE 4 NOMINAL DIMENSIONS FIGURES 814 & 818 Figure 814 Figure 818 A B Approx. A B Approx. Inches Inches Weight Lbs. Part Number Inches Inches Weight Lbs. (mm) (mm) (kg) (mm) (mm) (kg) 1.13 0.56 0.33 86340 1.38 0.31 0.18 (28,7) (14,2) (0,15) (35,1) (7,9) (0,08) 1.31 0.75 0.50 86341 0.56 0.26 (33,3) (19,0) (0,23) (41,4) (14,0) (0,11) 1.50 0.81 0.85 86230 1.75 0.38 0.44 (38,1) (20,6) (0,38) (44,4) (9,7) (0,20) 1.75 1.06 1.30 86231 2.00 0.56 0.54 (44,4) (26,9) (0,59) (5018) (14,0) (0,24) 1.94 1.19 1.63 86232 2.19 0.75 0.71 (49,3) (30,2) (0,74) (55,6) (19,0) (0,32) 2.25 1.50 2.63 86233 2.63 1.13 1.15 (57,1) (38,1) (1,19) (66,8) (28,7) (0,52) 2.69 1.56 4.55 86234 3.00 0.75 2.29 (68,3) (39,6) (2,06) (76,2) (19,0) (1,04) TFPI7I0 Page 6of 10 0 Page 7 of 10 TFPI7IO FIGURE 815 REDUCING TEE Nominal Pipe Size Figure 815 Approx. ANSI Inches A B C D E F Weight Part DN Inches Inches Inches Inches Inches Inches Lbs. Number mm (mm) (mm) (mm) (mm) (mm) (kg) 1-1/2x1-114x112 1.44 1.31 1.69 0.69 0.63 1.13 1.03 86257 0N40 x 32 x 15 (36,61 (33,3) (42,9) (17,5) (16,0) (28,7) (0,47) 1-1/2x1-1/4x3/4 1.50 1.44 1.75 0.75 0.75 1.19 1.10 86258 DN40x32x20 (38,1) (36,6) (44,5) (19,0) (19,0) (30,1) (0,50) 1-112x1-1/4x1 1.63 1.56 1.81 0.88 0.88 1.13 1.31 86259 DN40x32x25 (41,4) (39,7) (46,0) (22,4) (22,4) (28,7) (0,59) _______ 1-1/2x1-1/4x2 2.19 2.13 2.00 1.44 1.44 1.25 1.94 86260 DN40 x 32 x 50 (55,6) (54,1) (50,8) (36,6) (36,6) (57,1) (0,88) 1-1/2x1-1/2x1/2 1.44 1.44 1.69 0.69 0.69 1.13 1.14 86261 DN40 x 40 x 15 (36,6) (36,6) (42,9) (17,5) (17,5) (28.7) (0,52) 1-112x 1-112x3/4 1.50 1.50 1.75 0.75 0.75 1.19 1.23 86262 DN40x40x20 (38,1) (38,1) (44,4) (19,0) (19,0) (30,1) (0.56) 1-112x1-1/2x1 1.63 1.63 1.81 0.88 0.88 1.13 1.38 86263 DN40 x 40 x 25 (41,2) (41,2) (46,0) (22,4) (22,4) (28,7) (0,62) 1-1/2x1-112x1-1/4 1.81 1.81 1.88 1.06 1.06 1.19 1.50 86264 0N40 x 40 x 32 (46,0) (46,0) (47,6) (27,0) (27,0) (30,1) 1-1/2x1-112x2 2.19 2.19 2.00 1.44 1.44 1.25 2.00 86265 DN4O x 40 x 50 (55,5) (55,5) (50,8) (36,6) (36,6) (31,7) (0,91) 2x 1 x2 2.25 2.00 2.25 1.50 1.31 1.50 2.18 86266 DN5O x 25 x 50 (57.2) (50,8) (57,2) (38,1) (33,3) (38,1) 2x1-1/4x2 2.25 2.13 2.25 1.50 1.44 1.50 2.31 86267 DN5O x 32 x 50 (57,2) (54,1) (57,2) (38,1) (36,6) (38,1) (1,05) 2x1-1/2x1/2 1.50 1.44 1.88 0.75 0.69 1.31 1.50 86268 DN5O x 40 x 15 (38,1) (36,6) (47,8) (19,0) (17.5) (33,3) (0,68) 2x1-1/2x3/4 1.63 1.50 1.94 0.88 0.75 1.38 1.61 86269 DN50 x 40 x 20 (41,4) (38,1) (49,3) (22,4) (19,0) (35,0) (0,73) 2 x 1-1/2 x 1.75 1,63 2.00 1.00 0.88 1.31 1.65 86270 DN5O x 40 x 25 (44,5) (41,4) (50,8) (25.4) (22,4) (33,3) (0,75) 2x1-112x1-1/2 2.06 1.94 2.19 1.31 1.19 1.44 2.03 86272 0N50 x 40 x 40 (52.4) (49,2) (55,5) (33,3) (30,2) (36,6) (0,92) 2x1-1/2x2 2.25 2.19 2.50 1.50 1.44 1.50 2.37 86273 DN50 x 40 x 50 (57,1) (55,5) (63,5) (38.1) (36,6) (38,1) (1,07) 2x2x112 1.50 1.50 1.88 0.75 0.75 1.31 1.50 86222 DN50 x 50 x 15 (38,1) (38,1) (47,8) (19,0) (19,0) (33,3) (0,68) 2x2x3/4 1.63 1.63 1.94 0.88 0.88 1.38 1.67 86223 DN50x50x20 (41,4) (41,4) (49,3) (22,4) (22,4) (35,0) (0,76) 2x2x1 1.75 1.75 2.00 1.00 1.00 1.31 1.91 86224 DN50 x 50 x 25 (44,5) (44,5) (50,8) (25,4) (25.4) (33,3) (0,86) 2 x 2 x 1-1/4 1.88 1.88 2.13 1.13 1.13 1.44 2.05 86225 DN50 x 50 x 32 (47,8) (47,8) (54,1) (28,7) (28,7) (36,6) (0,93) 2x2x1-1/2 2.00 2.00 2.19 1.25 1.25 1.50 2.11 86226 DN50x50x40 (50,8) (50,8) (55,6) (31,8) (31.8) (38.1) (0,96) 2x2x2-112 2.63 2.63 2.38 1.75 1.88 1.44 3.67 86227 DN50 x 50 x 65 (66,8) (66,8) (60,5) (44,5) (47.8) (36.6) (1,66) 2-1/2x2x3/4 1.75 1.63 2.31 0.63 0.88 1.75 2.22 86274 DN65 x 50 x 20 (44,5) (41,4) (58,7) (15.9) (22.4) (44,5) (1,01) TABLE 5(2 0F2) NOMINAL DIMENSIONS FIGURE 815 Page 8 of 10 TFPI7IO =- FIGURE 820 FIGURE 830 FIGURE 719 CAP BRASS SEAT UNION PLUG Nominal Pipe Figure 820 Figure 830 Figure 719 Size ANSI A Approx. A B Approx. A Approx. Inches Inches Weight Lbs. Part Number Inches Inches Weight Lbs. Part Number Inches Weight Lbs. Part Number DN (mm) (kg) (mm) (mm) (kg) (mm) (kg) 1/2 DN15 0.88 (22,4) 0.15 (0106) 72776 166 (47,8) 0.81 (20,6) 0.47 (0,21) 86207 0.94 (23,9) 0.10 (0,04) 86292 3/4 DN20 1.00 (25,4) 0.22 (0,10) 72777 2.00 (50,8) 0.94 (23,9) 0.66 (0,30) 86275 1.13 (28,7) 0.18 (0,08) 86293 1 DN25 1.18 (30,0) 0.33 (0,15) 72824 2.19 (55,6) 0.81 (20,6) 1.08 (0,49) 86276 1.25 (31,7) 0.28 (0,13) 86294 1-1/4 0N32 1.31 (33,3) 0.54 (0,24) 72756 2.50 (63,5) 1.06 (26,9) 1.54 (0170) 86277 1.38 (35,1) 0.50 (0,23) 86295 1-1/2 DN40 1.38 (35,1) 0.68 (0,31) 72822 2.63 (66.8) 1.19 (30,2) 2.03 (0192) 86278 1.44 (36,6) 0.70 (0,32) 86296 2 0N50 1.50 (38,1) 0.96 (0,43) 72823 3.13 (79,5) 1.63 (41,4) 3.15 (1,43) 86279 1.50 (381) 0.90 (0,41) 86297 2-1/2 1.75 1.80 72825 - - - - - - - 0N65 (44,5) (0,82) TABLE 6 NOMINAL DIMENSIONS FIGURES 820,830 & 719 TFPI7IO Page 9 of 10 I!' FIGURE 825 FIGURE 827 FIGURE 816 EXTENSION PIECE HEX BUSHING REDUCING COUPLING Nominal Pipe Figure 825 Figure 827 Figure 816 Size Extension Piece Hex Bushing Reducing Coupling A Approx. A Approx. A B Approx ANSI Inches Inches Weight Part ,flC Weight Part Inches Inches Weight Part ON (mm) Lbs. Number (mm) Lbs. Number (mm) (mm) Lbs. Number (kg) (kg) (kg) 112x1/2 1.50 0.20 72751 - - - .- - - - DN15x15 (38,1) (0,09) 112x112 2.00 0.27 72980 - - - - - - - 0N15 x 15 (5018) (0.12) 314x3/4 1.50 0.22 72981 - - - - - - - DQ x 20 (38,1) (0110) 314 x 3/4 2.00 0.31 73982 DN20 x 20 (50,8) (0,14) - - - - 3/4x 1/2 1.75 0.69 0.38 86772 DN20x 15 - - - - (43,2) (17,5) (0,17) 1 x 112 1.06 0.22 72726 1.63 0.50 0.38 86228 DN25 x 15 - - (26,9) (0110) (42,9) (12,7) 1 x3/4 1.06 0.18 72762 1.75 0.50 0.53 86229 0N25 x 20 - - - (26,9) (0,08) (43,2) (12,7) (0,24) 1-14x 1 1.19 0.31 72763 - - - - DN32x25 - - - (30,2) (0,14) 1-112x1 1.25 0.53 72757 - - - - DN4O x 25 - - (31,7) (0,24) 1-1/2x1-114 1.25 0.35 72764 - - - - DN40 x 32 - (31,7) (0.10) 2x 1 1.38 0.75 72759 - - - - DN50x25 - - - (35,1) (0,34) 2 x 1-114 1.38 0.69 72761 - - - - DN5Dx32 - (35,1) (0,31) 2 x 1-112 1.38 0.62 72775 - - - - DN50x40 - - (35,1) (0,28) TABLE 7 NOMINAL DIMENSIONS FIGURE 825,827 & 816 8 tqCo Fire & Building liProducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 40-5 Strap S General Description ,7_ f_• VdS / See Fire Protection S ~) 0 Submittal Sheet for FM Pressure Rating and Listing/Approval Information The Fig ure4O-5 Strap lsan economical alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap may be used with full lengths of pipe and eliminates threading and welding, decreasing waste and installation time. The 40-5 Strap may be used in wet dry pipe and deluge systems. WARNING The Figure 40-5 Strap described herein must be installed and maintained in compliance with this document, as we/las wlththeapplicable standards of the National Fire Protection Association, in addition to the standards of any ofherautho rifles ha ving jurisdiction. Failure to do so mayimpair the performance of this device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. The installing contractor or sprinkler manufacturershould be contacted with any questions. Technical Data Figure: 40-5 Outlet: Threaded Approvals: UL, FM, ULC, and VdS; See Fire Protection Submittal Sheet for exact Listing /Approval information. Housing: Ductile iron conforming to ASTM A-536, Grade 65-45-12 Protective Coatings: Clear rust inhibitive coating Zinc electroplated conforming to ASTM B-633, Type Ill Service 2 (optional) U-Bolt: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Nuts: Carbon steel conforming to ASTM A-307, Grade A, Zinc electroplated Gasket: (specify when ordering) Grade "E" EPDM green color code. (See Data Sheet TFP1895 for aid in selecting proper gasket) Ordering Procedure When placing an order, indicate the full product name. Please specifythe quantity, figure number, type of gasket, Grade "E" EPOM, and size. Grinnell Grooved Piping Products, valves, accessories and other products are available throughoutthe U.S., Canada, and internationally, through a network of distribution centers. You may write directly or call 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in accordance with the applicable standards of theNational Fire Protection Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The Installing contractor or product manufacturer should be contacted relative to any questions. Any impairment must be immediately corrected. It is recommended that automatic sprinkler systems be Inspected, tested, and maintained by a qualified Inspection Service. Limited Warranty Products manufactured by Tyco Fire Products are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment bylyco Fire Products. No warranty is given for products or components manufactured by companies not affiliated by ownership with Tyco Fire Products orfor products and components which have been subject to misuse, im proper installation, corrosion, orwhich have not been installed, maintained, modified or repaired in accordance with applicable Standards of the National Fire Protection Association (NFPA), and/or the standards of any otherAuthorities Having Jurisdiction. Materials found bylyco Fire Products to be defective shall be either repaired or replaced, at Tyco Fire Products'sole option. Tyco Are Products neither assumes, nor authorizes any person to assumefor,anyotherobIigationinconnectionwh the sale of products or parts of products. Tyco Fire Productsshall notbe responsibleforsprinklersystern designerrorsorinaccurateorincompleteInformation supplied by Buyer or Buyers representatives. IN NO EVENT SHALL TYCO FIRE PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIALDAMAGES, INCLUDING BUTNOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER1YCOFIREPRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. Page 1 of 2 September 2004 TFPI72O Pipe Nominal Dimensions Hole Net A B C D Size Size Wt. Run x Inches Inches Inches Inches Inches Lbs. Branch mm mm mm mm mm Kg- 1 '/4" X /2" 2.00 1.50 3.50 1.20 1/ie 0.84 50.8 38.1 88.9 30.5 1 30.2 0.4 11/4" X3/4" 2.00 1.50 3.50 1.20 1/i& 0.88 50.8 38.1 88.9 30.5 30.2 0.4 11/4"X 1' 2.31 1.68 3.50 1.20 1/i 1.13 58.7 42.7 88.9 30.5 30,2 0.5 11/20 X /2" 2.12 1.62 3.50 1.32 1/16 0.84 53.8 41.1 88.9 33.5 1 30.2 0.4 11/20 x 3/40 2.12 1.62 3.50 1.32 1/16 0.88 53.8 41.1 88.9 33.5 30.2 0.4 11/20 x 1, 2.43 1.80 3.50 1.32 1/I6 1.13 61.7 45.7 88.9 33.5 30.2 0.5 20 x 1/20 2.36 1.86 3.74 1.55 1/i 0.88 59.9 47.2 95.0 39.4 30.2 0.4 2 x 3/40 2.36 1.86 3.74 1.55 13'1e 0.95 59.9 47.2 95.0 39.4 30.2 0.4 2"x 1' 2.67 2.04 3.74 1.55 13/16 1.16 67.8 51.8 95.0 39.4 30.2 0.5 21/2'x1/2' 2.61 2.11 4.25 1.80 1/1 0.90 66.3 53.6 108.0 1 45.7 30.2 1 0.4 21/2 X3/4" 2.61 2.11 4.25 1.80 1/t6 0.99 66.3 53.6 108.0 45.7 30.2 0.4 21/2 x 1' 2.92 2.29 4.25 1.80 13A6 1.21 74.2 58.2 108.0 45.7 30.2 0.5 Item Description 1 Housing 2 Gasket 3 Flanged Nut 4 U-Bolt Fitting Size Equivalent Length (1 inch pipe) 1h/4 X 1" 8 V/2"X 1 6 2'x 1° 6 211,."x 1" 4 The friction loss for these outlets is specified in equivalent length of 1 inch Schedule 40 (C=120) pipe. Page 2 of 2 TFP1 720 Figure 40-5 Strap The 1 inch outlets can be used with a nipple leading Note: Outlet threads conforming to ISO 7-1 are available, contact directly to a sprinkler. These fittings should be used Tyco Fire Products. for hydraulically calculated systems only. (:12) General Notes: Ills the Designer's responsibility to select products suitable for the intended service and to ensure ISO that pressure ratings and performance data is not exceeded. Always read and understand the installation 9001 instructions (I1-1-1000). Never remove any piping component or correct or modify any piping deficiencies without first depressurizing and draining the system. Material and gasket selection should be verified to be compatible for the specific application. . Certified Company TYCO FIRE PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19946 Printed U.S.A. Upright Vertical Sidewall le Reliabk Model Fl FR56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Pendent/F1/F2/FP Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Pendent Model F1FR42, F1FRXLH & Fl FR28 Sprinkler Types Standard Upright Standard Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types* Standard Pendent Less than 0.25% Lead Content Listing & Approvals Underwriters Laboratories Inc. and Certified for Canada (cULus). Factory Mutual Approvals (FM) Loss Prevention Council (LPCB, UK) VdS Schad enverhUtung GmbH *NSF Certified to NSF/ANSi Standard 61 Annex G EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA 1425), 0786-CPD-40252 (RA1 475) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & Fl FR28 Series Sprinklers are quick response sprinklers which combine the durability of a standard sprin- kler with the attractive low profile of a decorative sprinkler. The Models F1FR56, F1FR56LL, F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model F1 FR56, F1FR56LL, Bulletin 014 Rev. L Model Fl FR Series Quick Response Standard Spray LI Pendent Horizontal Sidewall ,in. r.. •• Recessed Concealed Horizontal Sidewall Pendent XLH Upright XLH Pendent F1FR42, F1FR42LL, F1FRXLH & F1FR28 Series sprinklers to apply wa- ter to a fire much faster than standard sprinklers of the same temperature rat- ing. The glass bulb consists of an accu- rately controlled amount of special fluid hermetically sealed inside a precisely manufactured glass capsule. This glass bulb is specially constructed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Conventional Recessed Pendent/Fl/F2 Recessed Pendent/FP XLH Recessed Pendent F1/F2 1. XLH Recessed Pendent FP Reliable Automatic Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Application Quick response sprinklers are used in fixed fire protection systems: Wet, Dry, Deluge or Preaction. Care must be • exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Association or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and standard re- sponse sprinklers should not be intermixed. *Pin tie Deflector (XLH Oniy e _ Load Screw Washer Bulb Frame Cup O14FGO6A Model F1FR42, F1FRXLH Upright Technical data: Thread Max. Mm. Temperature Models Discharge Coefficient Response Size Working Working Rating Finish Pressure Pressure F1FR56 **F1 FR56LL(1) K 5.6 Quick 1/2 NFl See See F1FR42 **F1 FR42LL1 K 4.2 Response (R1/2) 175 PSI 7 PSI "Temperature "Finish Table" Fl FRXLH Ratings" Table. F1FR28 K2.8 " Low Lead Sprinklers available only with Temperature Rating 200°F/93°C Material Data: Frame Deflector Load Screw *Pintle Cup Washer Bulb DZR Brass CDA Alloy 260, CDA Alloy 220 CDA Alloy 360 CDA Alloy 360 CDA Alloy 651 Nickel Alloy 440 or Alloy 360 QM Brass or or or coated with PTFE Adhesive Glass **Low Lead Brass or CDA Alloy5lo CDA Alloy 544 CDA Alloy 544 CDA Alloy 693 Tape 2. Model Fl FR56, Upright, Pendent & Conventional Sprinklers Model Fl FR42, Fl FRXLH & Fl FR28 Upright & Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread ____________ Nominal K Factor _______________ Sprinkler (SIN) __________ Approval __________ Sprinkler Identification Number Orifice Size US Metric Height Organization Upright Pendent Standard-Upright (SSU) and Pendent Deflectors Marked to Indicate Position 1/2"(15mm) (1) 1/2" NPT (RI/2) 5.6 I 80 2.25" (57mm) 1, 2, 3,4, 6 I 7/16(10mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) 1 RA1423 14 RA14134 3/8(10mm) 1/2" NPT(R1/2) 2.8 40 2.25" (57mm) 1 RA142114 RA14114 Conventional-Install in Upright or Pendent Position 15mm (I) 1/2" NPT (R1/2) 5.6 1 80 1 57mm 1 3, 4, 6 RA1475 3 cULus listed corrosion resistant (Polyester coated) sprinkler. Polyester coated FM approved sprinkler. Polyester coated LPCB & VdS approved sprinkler RA1425, RA1414 & RA1475. Electroless Nickel PTFE (Teflon®)* Plated - cULus listed Corrosion Resistant S Upright Pendent Conventional Model Fl FR56LL & Fl FR42LL Pendent Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Orifice Thread ____________ Nominal K Factor ________________ Sprinkler (SIN) __________ Approval __________ Sprinkler Identification Number Size US J Metric Height Organization Pendent Standard-Pendent Deflectors Marked to Indicate Position 1/2"(15mm)" 1/2" NPT(R1/2) 5.6 I 80 2.25" (57mm) 1,5 RA1415 7/16" (11 mm) 1/2" NPT(R1/2) 4.2 60 2.25" (57mm) 1,5 RA1410 cULus listed corrosion resistant (Polyester coated) sprinkler. S as *DuPont Registered Trademark 3.