Sprinkler Permit
Permit No: AS020150
Job Address: 1808 ASTON AV
Permit Type: SPRINK
Parcel No: 2121200700
Lot #: 0
Reference No.:
PC #:
Status: ISSUED
Applied 10/28/2002
Approved: 11/5/2002
Issued: 11/5/2002
Inspector:
Project Title: SPEC SUITE 240
Applicant: Owner:
ASTON VIEWS L L C
8799 BALBOA AVE #260
SAN DIEGO CA
Fees ($) Add'l Fees ($) Total ($) Balance ($)
100 0 '100 0
Aso2-o l sb
Vigo
Model BV-20 QR
8.0 K-factor
Quick Response
Extended Coverage Light Hazard
Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler
Tyco Fire Products --- www.centralsprinkler.com
451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA
Customer Service/Sales: Tel: (215) 362-0700/ Fax: (215) 362-5385
Technical Services: Tel: (800) 381-9312 /Fax: (800) 791-5500
CENTRAL
General
IL, Description
The Central Model BV-20 QR,
8.0 K-factor Quick Response, Extended
Coverage Light Hazard (ECLH)
Pendent and Recessed Pendent
Sprinklers are decorative glass bulb
sprinklers designed for use in light
hazard occupancies such as churches,
hospitals, offices, and restaurants.
They are intended for use in automatic
sprinkler systems designed in accor-
dance with standard installation rules
(e.g., NFPA 13) for the protection of
light hazards up to a maximum cover-
age area of 400 it' (37,2 m2), as
compared to the maximum coverage
area of 225 W (20,9 m2) for standard
coverage sprinklers.
The recessed version of the Central
Model BV-20 QR ECLH, intended for
use in areas with a finished ceiling, uses
a two-piece Model ELO Recessed
Escutcheon. The Model ELO Recessed
Escutcheon provides up to 3/4 inch
(19,1 mm) of total adjustment from the
flush pendent position. The adjustment
provided by these Recessed Escutch-
eons reduces the accuracy to which the
fixed pipe drops to the sprinklers must
be cut.
Operation: The glass bulb contains a
fluid which expands when exposed to
heat. When the rated temperature is
reached, the fluid expands sufficiently to
shatter the glass bulb, which then
allows the sprinkler to activate & flow
water.
WARNING
The Model BV-20 OR ECLH Pendent &
Rec. Pendent Sprinklers described
herein must be installed and maintained
in compliance with this document, as
well as with the applicable standards of
the National Fire Protection Association,
in addition to the standards of any other
authorities having jurisdiction. Failure to
do so may impair the integrity of these
devices.
The owner is responsible for maintain-
ing their fire protection system and
devices in proper operating condition.
The installing contractor or sprinkler
manufacturer should be contacted
relative to any questions.
Technical
Data
Sprinkler Identification Number
SIN C4232
Approvals
UL & ULC Listed.
(The approvals apply only to the service
conditions indicated in the Design Criteria
Section)
Maximum Working Pressure
175 psi (12,1 bar)
Pipe Thread Connection
3/4 inch NPT
Discharge Coefficient
K = 8.0 GPM/psi' (115,2 LPM/bar119
Temperature Ratings
1350F/570C or 1559F1680C
Finishes
Sprinkler White Polyester, Chrome
Plated, or Natural Brass
Rec. Escutcheon: White Coated, Chrome
Plated, or Brass Plated
Physical Characteristics
The Model BV-20 QR ECLH Pendent &
Rec. Pendent Sprinklers utilize a dezincifi-
cation resistant (DZR) bronze frame and a
3 mm bulb. The two-piece button
assembly is brass and copper. The
sprinkler frame orifice is sealed with a
gasketed spring plate (Belleville Seal)
consisting of a beryllium nickel disc spring
that is sealed on both its inside and
outside edges with a Teflon gasket The
compression screw is bronze, & the
deflector is brass.
Extended
Coverage Light
Hazard Pendent
& Rec. Pendent
Sprinklers
Figure 1 - Cross Section
Model BV-20 OR ECLH,
Pendent Sprinkler
GASKETED SPRING
BUTTON PLATE
ASSEMBLY (BELLEVILLE
SEAL)
SPRINKLER
FRAME
GLASS BULB iUL.-. flJj7.
OPERATING
ELEMENT
/
DEFLECTOR COMPRESSION
SCREW
No. 2-10.0
w
3Design
Criteria
The Model BV-20 OR, Extended Coverage Light Hazard
(ECLH) Pendent and Recessed Pendent Sprinklers are UL
and ULC listed for use in light hazard occupancies, using the
design criteria in Table 1 as well as any additional
requirements specified in current NFPA 13 Standards for
Extended Coverage Pendent Sprinklers.
The minimum lateral spacing between the BV-20 OR ECLH
Pendent and Recessed Pendent Spnnkers to prevent cold
soldering, is 8 feet (2,4 m).
The Model BV-20 OR Sprinklers can be used with any metalic
flush or extended escutcheon, provided the maximum ceiling
to top of sprinkler deflector dimension specified in NFPA 13 is
maintained. For recessed applications, only the Model ELO
Recessed Escutcheon Assemblies may be used. rI
Installation
The Model BV-20 OR ELCH Sprinklers must be installed in
accordance with the following instructions:
NOTES
Do not install any bulb type sprinkler if the bulb is cracked
or there is a loss of liquid from the bulb. With the sprinkler
held horizontally, a small air bubble with an approximate
diameter of 1/16 inch should be present.
A leak tight 3/4 inch NPT sprinkler joint should be obtained
with a torque of 10 to 20 ft.lbs. (13,4 to 26,8 Nm). A maximum
of 30 ft.lbs. (40,7 Nm) of torque is to be used to install 3/4 inch
NPT sprinklers. Higher levels of torque may distort the
sprinkler inlet with consequent leakage or impairment of the
sprinkler.
Do not attempt to compensate for insufficient adjustment in an
Escutcheon Plate by under- or over-tightening the Sprinkler.
Readjust the position of the sprinkler fitting to suit.
Step 1. Pendent sprinklers must be installed only in the
pendent position. The deflector is to be parallel to the ceiling,
roof, or mounting surface, as applicable.
Step 2. After installing the ELO support cup (or other escutch-
eon, as applicable) over the sprinkler pipe threads & with pipe
thread sealant applied to the pipe threads, hand tighten the
sprinkler into the sprinkler fitting.
Step 3. Wrench tighten the sprinkler using only the following
wrenches:
BV-20 OR Pend - W-Type 3 (Ref. Fig. 3)
BV-20 OR Rec. Pend - ELO Offset (Ref. Fig. 4)
Wrenches are to be applied to the sprinkler wrench flats (Ref.
Fig. 2) only.
a
Care &
Maintenance
The Model BV-20 OR ECLH Sprinklers must be main-
tained and serviced in accordance with the following
instructions.
NOTES
Absence of an escutcheon which is used to cover a
clearance hole, may delay the time to operation in a fire
situation.
Before closing a fire protection system main control valve
for maintenance work on the fire protection system it
controls, permission to shut down the affected fire protec-
tion systems must be obtained from the proper authorities.
All personnel who maybe affected by this action must be
notified.
Sprinklers which are found to be leaking or exhibiting
visible signs of corrosion must be replaced.
Automatic sprinklers must never be shipped or stored
where their temperatures will exceed 100°F/380C and they
must never be painted, plated, coated or otherwise altered
after leaving the factory. Modified sprinklers must be
replaced. Sprinklers that have been exposed to corrosive
products of combustion, but have not operated, should be
replaced if they cannot be completely cleaned by wiping the
sprinkler with a cloth or by brushing it with a soft bristle
brush.
Care must be exercised to avoid damage - before, during,
and after installation. Sprinklers damaged by dropping,
striking, wrench twist/slippage, or the like, must be re-
placed. Also, replace any sprinkler that has a cracked bulb
or that has lost liquid from its bulb (Ref. Installation Sec-
tion).
The owner is responsible for the inspection, testing, and
maintenance of their fire protection system and devices in
compliance with this document, as well as with the appli-
cable standards of the National Fire Protection Association
(e.g., NFPA 25), in addition to the standards of any other
authorities having jurisdiction. The installing contractor or
sprinkler manufacturer should be contacted relative to any
questions.
It is recommended that automatic sprinkler systems be
inspected, tested, and maintained by a qualified Inspection
Service.
:ATE 01 S
J~ 7*A, ~ 11
A :Y4Ike1]
4021 506 & 8.0 K-factor
Quick Response
Standard Coverage
Upright, Pendent & Rec. Pendent Glass Bulb Automatic Sprinkler
Tyco Fire Products --- www.centralsprinkler.com
451 North Cannon Avenue, Lansdale, Pennsylvania 19446 --- USA
Customer Service/Sales: Tel: (215) 362-0700 I Fax: (215) 362-5385
Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500
ASc2o je
CENTRAL
A"General
L Description
The Central Model By-OR, 4.2 & 5.6
K-factor (7/16" & 1/2" orifice) & Model
BVLO-QR, 8.0 K-factor (17/32" orifice),
Upright, Pendent, and Rec. Pendent
Sprinklers are quick response - standard
coverage, decorative glass bulb type
spray sprinklers designed for use in light &
ordinary hazard, commercial occupancies
such as banks, hotels, shopping malls etc.
The recessed version of the Central Model
By-OR, intended for use in areas with a
finished ceiling, uses a two-piece Model
BV Res/QR Recessed Escutcheon
(Vented or Unvented). The Model BV
Res/QR Recessed Escutcheon provides
up to 3/8 inch (9,5 mm) of total adjustment
from the flush pendent position. The
recessed version of the Central Model
BVLO-QR, also intended for use in areas
with a finished ceiling, uses a two-piece
Model ELO Recessed Escutcheon. The
Model ELO Recessed Escutcheon
provides up to 3/4 inch (19,1 mm) of total
adjustment from the flush pendent
position. The adjustment provided by
these Recessed Escutcheons reduces the
accuracy to which the fixed pipe drops to
the sprinklers must be cut
These sprinklers are available with a
polyester coating that may be utilized to
extend the life of copper alloy sprinklers
beyond that which would otherwise be
obtained when exposed to corrosive
atmospheres.
Although polyester coated sprinklers have
passed the standard corrosion tests of the
applicable approval agencies, the testing
is not representative of all possible
corrosive atmospheres. Consequently, it is
recommended that the end user be
consulted with respect to the suitability of
this corrosion resistant coating for any
given corrosive environment. The effects
of ambient temperature, concentration of
chemicals, and gas/chemical velocity,
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will-be
exposed.
Operation: The glass bulb contains a fluid
which expands when exposed to heat
When the rated temperature is reached,
the fluid expands sufficiently to shatter the
glass bulb, which then allows the sprinkler
to activate & flow water.
WARNING
The Model By-OR & BVLO-QR Uptight
Pen dent & Rec. Pendent Sprinklers
descnbed herein must be installed and
maintained in compliance with this
document, as well as with the applicable
standards of the National Fire Protection
Association, in addition to the standards of
any other autho,ities ha ving jurisdiction.
Failure to do so may impair the integrity of
these devices.
The owner is responsible for maintaining
their fire protection system and devices in
proper operating condition. The installing
contractor or sprinkler manufacturer
should be contacted relative to any
questions.
Figure 1 - Cross Section
Model BVLO-QR,
Upright Sprinkler
COMPRESSION DEFLECTOR
SCREW /
GLASS BULB
OPERATING G
ELEMENT SPRINKLER
FRAME
BUTTON GASKETED SPRING
ASSEMBLY PLATE
(BELLEVILLE
SEAL)
Standard Spray
Upright, Pendent
& Rec. Pendent
Sprinklers
No. 1-7.0
Design 13Criteria
The Model BV-QR & BVLO-QR Upright,
Pendent & Rec. Pendent Sprinklers are
Standard Response, Standard Coverage,
Spray Sprinklers intended for fire
protection systems designed in
accordance with the standard installation
rules recognized by the applicable Listing
or Approval agency.
The 4.2 K-Factor, Model BV-QR
Sprinklers (Ref. Table 1) are UL & ULC
listed and NYC Approved for use in
accordance with current NFPA standards.
The 5.6 K-Factor, Model BV-OR
Sprinklers (Ref. Table 1) are UL & ULC
listed and NYC Approved for use in
accordance with current NFPA standards,
and FM Approved for use in accordance
with the FM Loss Prevention Data Sheets,
The 8.0 K-Factor, Model BVLO-QR
Sprinklers (Ref. Table 2) are UL & C-UL
listed for use in accordance with current
NFPA standards, and FM Approved for
use in accordance with the FM Loss
Prevention Data Sheets.
The Model BV-QR & BVLO-QR
Sprinklers can be used with any metalic
flush or extended escutcheon, provided
the maximum ceiling to top of sprinkler
deflector dimension specified in NFPA 13
is maintained. For recessed applications,
only the Model BV Res/OR Vented or
Unvented, (for 4.2 & 5.6 K-factor
sprinkers) and ELO (for 8.0 K-factor
Sprinklers) Recessed Escutcheon
Assemblies may be used.
NOTE
Inquiries concerning the appropriateness
of polyester coated sprinklers fora given
convsWe environment should be
submitted to the attention of the Technical
Services Department Polyester coated
Sprinklers are not suitable for use in open
sprinkler applications.
Installation
The Model By-OR & BVLO-QR Sprinklers
must be installed in accordance with the
following instructions:
NOTES
Do not install any bulb We spnnkier if the
bulb is cracked or there is foss of liquid
from the bulb. With the sprinkler held
horizontally, a small air bubble should be
present The diameter of the air bubble is
approximately 1/16 inch (1,6 mm) for the
135 °F/5 7°C to 3/32 inch (2,4 mm) for the
250°F/121 °C rating.
A leak tight 1/2 inch NPT spnnklerjoint
should be obtained with a torque of 7 to 14
ftlbs. (9,5 to 19,0 Nm). A maximum of
(Continued on Page 4)
Figure 3- Model BVLO-QR, Upright, Pendent &
Rec. Pendent Sprinkler
1-3/8
3/4" NPT 1(35,0 mm)
,vupno
2-1/8"
(54,0 mm)
2-1/8"
WRENCH (54,0 mm)
FLAT
ENTRAL
1-3fl6J -
(30,2 mm)
ELEVATION VIEW It I FACE OF
" REDUCING
COUPLING
(9,5 mm) Ej3/
,
/r
"i'
,74HIN30
OUTER
ESCUTCHEON)/
111k FINISHED
A' 1 \C
E'LING LINE
RING I WRENCH (
/ FLAT MODEL ELO
RECESSED I I RECESSED
SUPPORT CUP I 2-1/4" (57,2 mm) Mm. ESCUTCHEON
2-3/4" (69,9 mm) Max.
3-1/4"(82,6mm)-----------.'l
Table 2- Laboratory Listings and Approvals, Model BVLO-QR
SPRINKLER FINISH & STYLE
Temperature
Rating
Bulb
Color Code
Natural
Brass
Chrome
Plated
Polyester
Coated
Recessed
135°F/57C Orange 1,2,3 1,2,3 1,2,3 1,2,3
155°F/689C Red 1,2,3 1,2,3 1,2,3 1,2,3
175017/790C Yellow 1,2,3 1,2,3 1,2,3 1,2,3
200°F1930C Green 1,2,3 1,2,3 1,2,3 1,2,3
250°F/121°C Blue 1,2,3 1,2,3 1,2,3
Listed by Underwriters Laboratories, Inc.
Listed by Underwriters Laboratories for use in Canada (C-UL).
Approved by Factory Mutual Research Corporation.