Loading...
HomeMy WebLinkAbout6166 INNOVATION WAY; ; AS140074; Permit9/14/22, 11:15 AM AS140074 Permit Data City of Carlsbad Sprinkler Permit 6166 INNOVATION Job Address: WY Permit Type: SPRINK Parcel No: 2132621426 Lot #: 0 Permit No: AS140074 Status: ISSUED Applied 3/6/2014 Approved: 3/6/2014 Reference No.: Issued: 3/6/2014 PC #: Inspector: Project Title: EGGHEAD VENTURES IN RACK SPRIN IN-RACK FIRE SPRINKLER ADDITION TO EXISTING OVERHEAD SPRINKLERS Applicant: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY SAN MARCOS, CA 760-310-6122 Owner: EGGHEADVENTURES L L C 1340 SPECIALTY DR #1 VISTA CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 268 0 268 0 about:blank 1/1 EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 (760) 310-6122 FAX (760) 798-0556 AS 1 40074 Hydraulic Design Information Sheet Name: EGGHEAD VENTURES IN-RACK CALC Location: 6166 INNOVATION DR. Building: EXISTING Contractor: EPIC FIRE PROTECTION, INC. Calculated By: RAB Construction: M Combustible El Non-Combustible Date: 2-27-14 System No. 1 OF 1 Contract No. Drawing No. 1 OF 1 Ceiling Height 27 Ft. Z NFPA 13: [1 NFPA 231 El Other (Specify) El Specific Ruling SYSTEM DESIGN D Light Hazard Ordinary Hazard Group El 1 [1 NFPA231C: Figure: ]2El3 Curve: Extra Hazard Made By Date Area of Sprinkler Operation 2000 SQ FT System Type Density .30 Z Wet El Dry El Deluge El Pre-Action Area Per Sprinkler 82 SQ FT Sprinkler or Nozzle Hose Allowance GPM: Inside 0 Make TYCO Model TY-FRB Hose Allowance GPM: Outside 500 Size Y2" K-Factor: 5.6 Rack Sprinkler Allowance SEE CALCS Temperature Rating 155 CALCULATION SUMMARY GPM Required ?S. ( PSI Required At Base of Riser "C" Factor Used: Overhead 120 Underground 150 WATER SUPPLY Water Flow Test Pump Data Tank or Reservoir Date & Time BASE OF RISER Rated Capacity Capacity Static PSI CALC At PSI Elevation Residual PSI 1600 GPM AT 41.2 Elevation GPM Flowing AVAILABLE Well Elevation 0 Proof Flow GPM Location SITE Source of Information COMMODITY: STORAGE Commodity PLASTIC Class GROUP A Location RACKS Storage Height 20' Area Aisle Width 10' Storage Method: Solid Piled % Palletized %Rack 100 Rack El Single Row Conventional Pallet Double Row Slave Pallet El Multiple Row El Open Flue Spacing In Inches Longitudinal 6 Transverse 3 Horizontal Barriers Provided NA El Automatic Storage El Encapsulated El Solid Shelving Non-Encapsulated Clearance From Top of Storage to Ceiling 5 Ft. 0 In. 03-03-2014 PAGE 1 SUBMITTAL SERIAL NO:2932HY7 SUMMARY OF SPRINKLER OUTFLOWS ACTUAL MINIMUM SPR FLOW FLOW K-FACTOR PRESSURE 100 52.34 37.05 14.00 13.98 101 51.96 37.05 14.00 13.77 102 51.89 37.05 14.00 13.74 103 47.83 37.05 14.00 11.67 104 47.48 37.05 14.00 11.50 105 47.41 37.05 14.00 11.47 106 46.41 37.05 14.00 10.99 107 46.07 37.05 14.00 10.83 108 46.00 37.05 14.00 10.80 109 45.28 37.05 14.00 10.46 110 44.95 37.05 14.00 10.31 111 44.89 37.05 14.00 10.28 112 44.62 37.05 14.00 10.16 113 44.29 37.05 14.00 10.01 114 44.22 37.05 14.00 9.98 115 44.30 37.05 14.00 10.01 116 43.97 37.05 14.00 9.86 117 43.91 37.05 14.00 9.84 118 44.21 37.05 14.00 9.97 119 43.88 37.05 14.00 9.83 120 43.82 37.05 14.00 9.80 121 52.23 37.05 14.00 13.92 122 51.86 37.05 14.00 13.72 123 51.79 37.05 14.00 13.68 210 22.28 21.69 5.60 15.83 211 21.98 21.69 5.60 15.40 212 21.80 21.69 5.60 15.15 213 21.71 21.69 5.60 15.04 214 21.69 21.69 5.60 15.00 215 24.17 21.69 5.60 18.62 216 23.69 21.69 5.60 17.89 217 23.37 21.69 5.60 17.41 218 23.18 21.69 5.60 17.13 219 23.09 21.69 5.60 17.00 220 23.06 21.69 5.60 16.96 SUBMITTAL SERIAL NO:2932HY7 03-03-2014 PAGE 2 TOTAL WATER REQUIRED FOR SYSTEM OUTSIDE HOSE STREAMS AT 0 TOTAL WATER REQUIREMENT PRESSURE REQUIRED AT 0 MAXIMUM PRESSURE UNBALANCE IN LOOPS MAXIMUM VELOCITY FROM 10 TO 20 1375.62 GPM 500.00 GPM 1875.62 GPM 36.37 PSI 0.00 PSI 21.09 FPS SUBMITTAL SERIAL NO:2932HY7 Location Flow Pipe Fittings in Size & From To GPM IN Devices 213 214 2.203 L Q 21.69 F=0 F BN2 T 212 213DQ 21.71 2.203 L Q 43.40 F=0 F BN2 T 211 212DQ 21.80 2.203 L Q 65.20 F=0 F BN2 T 210 211DQ 21.98 2.203 L Q 87.18 F=0 F BN2 T 201 210DQ 22.28 2.203 L Q 109.46 F=T F BN2 T 219 ------------------ 220 2.203 L Q 23.06 F=0 F BN2 218 219DQ 23.09 2.203 L Q 46.15 F=0 F BN2 T 217 218DQ 23.18 2.203 L O 69.33 F=0 F 3N2 T 216 217DQ 23.37 2.203 L Q 92.70 F=0 F BN2 T 215 216DQ 23.69 2.203 L Q 116.39 F=0 F BN2 T 202 215DQ 24.17 2.203 L Q 140.55 F=T F BN2 T 117 ------------------ 120 2.703 L Q 43.82 F=0 F EN T 03-03-2014 PAGE 3 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI 8.00 C=120 PT 15.00 (214) 0.00 PE 0.00 8.00 0.0041 PF 0.03 8.00 C=120 PT 15.03 (213) 0.00 PE 0.00 8.00 0.0147 PF 0.12 8.00 C=120 PT 15.15 (212) 0.00 PE 0.00 8.00 0.0312 PF 0.25 8.00 C=120 PT 15.40 (211) 0.00 PE 0.00 8.00 0.0535 PF 0.43 4.00 C120 PT 15.83 (210) 11.60 PE 0.00 15.60 0.0814 PF 1.27 PT 17.10 (201) 8.00 C=120 PT 16.96 (220) 0.00 PE 0.00 T 46 PF 0.04 8.00 C=120 PT 17.00 (219) 0.00 PE 0.00 8.00 0.0165 PF 0.13 8.00 C=120 PT 17.13 (218) 0.00 PE 0.00 8.00 0.0350 PF 0.28 8.00 C=120 PT 17.41 (217) 0.00 PE 0.00 8.00 0.0599 PF 0.48 8.00 C=120 PT 17.89 (216) 0.00 PE 0.00 8.00 0.0912 PF 0.73 0.50 C=120 PT 18.62 (215) 11.60 PE 0.00 12.10 0.1293 PF 1.56 PT 20.18 (202) 7.08 C=120 PT 9.80 (120) 0.00 PE 0.00 7.08 0.0055 PF 0.04 SUBMITTAL SERIAL NO:2932HY7 03-03-2014 PAGE 4 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 114 117DQ 43.91 2.703 L 7.08 C=120 PT 9.84 (117) Q 87.73 F=0 F 0.00 PE 0.00 EN T 7.08 0.0200 PF 0.14 111 114DQ 44.22 2.703 L 7.08 C=120 PT 9.98 (114) Q 131.96 F=0 F 0.00 PE 0.00 BN T 7.08 0.0425 PF 0.30 108 111DQ 44.89 2.703 L 7.08 C=120 PT 10.28 (111) Q 176.85 F=0 F 0.00 PE 0.00 BN T 7.08 0.0730 PF 0.52 105 108DQ 46.00 2.703 L 6.00 C=120 PT 10.80 (108) Q 222.85 F=0 F 0.00 PE 0.00 BN T 6.00 0.1120 PF 0.67 22 105DQ 47.41 2.703 L 1.42 C=120 PT 11.47 (105) Q 270.26 F=T F 16.70 PE 0.00 BN T 18.12 0.1601 PF 2.90 PT 14.37 ( 22) 116 ------------------ 119 2.703 L 7.08 C=120 PT 9.83 Q 43.88 F=0 F 0.00 PE 0.00 BN T 7.08 0.0055 PF 0.04 113 116DQ 43.97 2.703 L 7.08 C=120 PT 9.87 (116) Q 87.86 F=0 F 0.00 PE 0.00 BN T 7.08 0.0200 PF 0.14 110 113DQ 44.29 2.703 L 7.08 C=120 PT 10.01 (113) Q 132.14 F=0 F 0.00 PE 0.00 BN T 7.08 0.0426 PF 0.30 107 110DQ 44.95 2.703 L 7.08 C=120 PT 10.31 (110) Q 177.09 F=0 F 0.00 PE 0.00 BN T 7.08 0.0732 PF 0.52 104 107DQ 46.07 2.703 L 6.00 C=120 PT 10.83 (107) Q 223.16 F=0 F 0.00 PE 0.00 EN T 6.00 0.1123 PF 0.67 21 104DQ 47.48 2.703 L 1.42 C=120 PTC=120 PT 11.50 (1 0.64 F=T F 16.70 PE 0.00 BN T 18.12 0.1605 PF 2.91 PT 14.41 ( 21) 115 ------------------ 118 2.703 L 7.08 C=120 PT 9.97 Q 44.21 F=0 F 0.00 PE 0.00 EN T 7.08 0.0056 PF 0.04 SUBMITTAL SERIAL NO:2932HY7 03-03-2014 PAGE 5 Location Flow Pipe Fittings Equiv Friction Pressure in Size & Length Loss Summary From To GPM IN Devices Ft PSI/Ft PSI 112 115DQ 44.30 2.703 L 7.08 C=120 PT 10.01 (115) Q 88.51 F=0 F 0.00 PE 0.00 BN T 7.08 0.0203 PF 0.14 109 112DQ 44.62 2.703 L 7.08 C=120 PT 10.15 (112) Q 133.13 F=0 F 0.00 PE 0.00 EN T 7.08 0.0432 PF 0.31 106 109DQ 45.28 2.703 L 7.08 C=120 PT 10.46 (109) Q 178.41 F=0 F 0.00 PE 0.00 BN T 7.08 0.0743 PF 0.53 103 106DQ 46.41 2.703 L 6.00 C=120 PT 10.99 (106) Q 224.82 F=0 F 0.00 PE 0.00 BN T 6.00 0.1139 PF 0.68 20 103DQ 47.83 2.703 L 1.42 C=120 PT 11.67 (103) Q 272.65 F=T F 16.70 PE 0.00 BN T 18.12 0.1627 PF 2.95 PT 14.62 ( 20) 102 ------------------ 123 2.703 L 7.08 C=120 PT 13.68 (123) Q 51.79 F=0 F 0.00 PE 0.00 BN T 7.08 0.0075 PF 0.05 22 102DQ 51.89 2.703 L 6.67 C=120 PT 13.73 (102) Q 103.67 F=T F 16.70 PE 0.00 BN T 23.37 0.0272 PF 0.64 12 22DQ 270.26 2.703 L 1.00 C=120 PT 14.37 ( 22) Q 373.93 F=T F 16.70 PE 0.43 NR T 17.70 0.2919 PF 5.17 PT 19.97 ( 12) 101 ------------------ 122 2.703 L 7.08 C=120 PT 13.72 (122) Q 51.86 F=0 F 0.00 PE 0.00 BN T 7.08 0.0075 PF 0.05 21 101DQ 51.96 2.703 L 6.67 C=120 PT 13.77 (101) Q 103.81 F=T F 16.70 PE 0.00 BN T 23.37 0.0273 PF 0.64 11 21DQ 270.64 2.703 L 1.00 C=120 PT 14.41 ( 21) Q 374.45 F=T F 16.70 PE 0.43 NR T 17.70 0.2926 PF 5.18 PT 20.02 ( 11) 100 ------------------ 121 2.703 L 7.08 C=120 PT 13.92 (121) Q 52.24 F=0 F 0.00 PE 0.00 EN T 7.08 0.0077 PF 0.05 SUBMITTAL SERIAL NO:2932HY7 Location Flow Pipe Fittings • in Size & From To GPM IN Devices 20 100DQ 52.34 2.703 L Q 104.57 F F=T EN T 10 20DQ 272.65 2.703 L Q 377.22 F=T F NR T 11 ------------------ 12 6.357 L Q 373.93 F=0 F FM T 200 11DQ 374.45 6.357 L Q 748.38 F=0 F FM T 201 ------------------ 202 2.703 L Q 140.55 F=0 F FM T 200 201DQ 109.46 2.703 L Q 250.01 F=T,E/BV F FM T 10 200DQ 748.38 6.357 L Q 998.40 F=0 F FM T 8 10DQ 377.22 6.357 L Q 1375.62 F=E F FM T 0 8 6.357 L Q 1375.62 F=E F FR T 03-03-2014 PAGE 6 Equiv Friction Pressure Length Loss Summary Ft PSI/Ft PSI 6.67 C=120 PT 13.97 (100) F 16.70 PE 0 23.37 0.0276 PF 0.65 1.00 C=120 PT 14.62 ( 20) 16.70 PE 0.43 17.70 0.2967 PF 5.25 PT 20.30 ( 10) 11.58 C=120 PT 19.97 ( 12) 0.00 PE 0.00 11.58 0.0045 PF 0.05 3.58 C=120 PT 20.02 ( 11) 0.00 PE 0.00 3.58 0.0164 PF 0.06 PT 20.08 (200) 8.00 C=120 PT 20.19 (202) 0.00 PE -3.47 8.00 0.0478 PF 0.38 15.00 C=120 PT 17.10 (201) 34.64 PE -3.90 49.64 0.1386 PF 6.88 8.00 C=120 PT 20.08 (200) 0.00 PE 0.00 8.00 0.0279 PF 0.22 44.00 C=120 PT 20.30 ( 10) 12.57 PE 0.00 56.57 0.0505 PF 2.86 26.00 C=120 PT 23.16 ( 8) 12.57 PE 11.27 38.57 0.0505 PF 1.95 PT 36.38 ( 0)