HomeMy WebLinkAbout4615 TELESCOPE AVE; ; FPR2021-0106; Permit4:1 tI:11 Is]41 (city of Carlsbad Print Date: 06/09/2022 Job Address: 4615 TELESCOPE AVE, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2073852000 Track #: Valuation: $419,942.45 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check#: Permit No: FPR2021-0106 Status: Closed - Finaled Single Family Fire Sprinkli Applied: 09/28/2021 Issued: 10/21/2021 Finaled Close Out: 06/09/2022 Final Inspection: INSPECTOR: Cheung, Nathaniel Salcedo, Felix Project Title: Description: TELESCOPE RESIDENCE - NEW 13D SYSTEM (20 HEADS) Applicant: SYMONS FIRE PROTECTION ANGELA ZUMAYA 12155 PAINE PL POWAY, CA 92064-7154 (619)588-6364 FPContractor: SYMONS FIRE PROTECTION INC 9475 CHESAPEAKE DR SAN DIEGO, CA 92123-1336-SAN DIEGO (619) 588-6364 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $137.00 FIRE NFPA 13D Single Family System (Plan Review) $271.00 FIRE Reinspection (per Inspection) $212.00 FIRE Reinspection (per Inspection) $212.00 Total Fees: $832.00 Total Payments To Date: $832.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov 4, w_ ff IaFg ISr.4&I'.'E • RESL)flEFLL • (ELI.QLE 12 155 PAiNE PLACE POWAY, CA 92064 HYDRAULIC CALCULATIONS FOR TELESCOPE AVENUE RESIDENCE FILE NUMBER: 21-0704.SDF DATE: SEPTEMBER 20, 2021 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm/ 512 sq.ft. AREA OF APLICATION: LIVING COVERAGE PER SPRINKLER: 256 sq.fi. NUMBER OF SPRINKLERS: 2 SPRINKLERS TOTAL SPRINKLER WATER FLOW REQUIRED: 27.0 gpm TOTAL WATER REQUIRED (including hose): 32.0 gpm FLOW AND PRESSURE (@BOR): 27.0 gpm @ 23.7 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD WATER DEPARTMENT CONTACT: GINA WATER PRESSURE INFORMATION: 66.0 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE: 9/2072021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE TWO HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 59.4 58.0 500.0 59.4 32.0 56.3 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 32.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 27.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 -2.0 SOURCE 56.3 32.0 2 0.0 - - - - 44.7 - - - 3 0.0 - - - - 31.7 - - - 4 10.0 - - - - 26.9 - - - 5 12.0 HOSE STREAM 23.7 5.0 6 20.5 - - - - 16.3 - - - 7 20.5 - - - - 13.4 - - - 8 24.5 - - - - 8.1 - - - 8A 24.0 K= 4.90 8.1 13.9 9 27.0 - - - - 7.0 - - - 9A 26.5 K= 4.90 7.0 13.0 10 20.5 - - - - 10.8 - - - bA 20.0 - - - - 11.0 - - - SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE' 9/20V2021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOE TITLE: TELESCOPE AVENUE RESIDENCE TWO HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 32.0 0.995 PL 30.00 PF 10.7 1 -2.0 SRCE 56.3 (N/A) 13.2 150 FTG TLG PE -0.9 2 0.0 0.0 44.7 0.0 0.265 TL 40.50 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 44.7 0.0 13.0 psi, 31.9 gpm 3 0.0 0.0 31.7 0.0 Pipe: 3 31.9 2.050 PL 55.00 PF 0.5 3 0.0 0.0 31.7 0.0 3.1 150 FTG 2L PE -4.3 4 10.0 0.0 26.9 0.0 0.008 TL 61.00 PV Pipe: 4 31.9 1.025 PL 5.00 PF 2.3 4 10.0 0.0 26.9 0.0 12.4 150 FTG EL PE -0.9 5 12.0 H.S. 23.7 5.0 0.229 TL 10.00 PV Pipe: 5 26.9 1.101 PL 8.00 PF 3.7 5 12.0 H.S. 23.7 5.0 9.1 150 FTG 2ET3RC PE -3.7 6 20.5 0.0 16.3 0.0 0.118 TL 31.00 PV Pipe: 6 26.9 1.101 PL 10.00 PF 3.0 6 20.5 0.0 16.3 0.0 9.1 150 FTG 2ER PE 0.0 7 20.5 0.0 13.4 0.0 0.118 TL 25.00 PV Pipe: 7 14.7 1.101 PL 55.00 PF 3.6 7 20.5 0.0 13.4 0.0 5.0 150 FTG 3E3TR PE -1.7 8 24.5 0.0 8.1 0.0 0.039 TL 92.00 PV Pipe: 8 13.9 1.101 PL 0.50 PF 0.2 8 24.5 0.0 8.1 0.0 4.7 150 FTG TR PE 0.2 8A 24.0 4.9 8.1 13.9 0.035 TL 6.50 PV Pipe: 9 0.8 1.101 PL 10.00 PF 0.0 8 24.5 0.0 8.1 0.0 0.3 150 FTG R PE -1.1 9 27.0 0.0 7.0 0.0 0.000 TL 11.00 PV Pipe: 10 13.0 1.101 PL 0.50 PF 0.2 9 27.0 0.0 7.0 0.0 4.4 150 FTG TR PE 0.2 9A 26.5 4.9 7.0 13.0 0.031 TL 6.50 PV Pipe: 11 -12.2 1.101 PL 19.50 PF 1.0 9 27.0 0.0 7.0 0.0 4.1 150 FTG 2E2R PE 2.8 10 20.5 0.0 10.8 0.0 0.027 TL 35.50 PV Pipe: 12 0.0 1.101 PL 14.00 PF 0.0 10 20.5 0.0 10.8 0.0 0.0 150 FTG ET2R PE 0.2 bA 20.0 0.0 11.0 0.0 0.000 TL 28.00 PV Pipe: 13 -12.2 1.101 PL 73.00 PF 2.6 10 20.5 0.0 10.8 0.0 4.1 150 FTG 2E8R PE 0.0 7 20.5 0.0 13.4 0.0 0.027 TL 95.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE-' 9/20/2021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE TWO HEAD CALC NOTES (HASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2019) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.006 gpm and a maximum imbalance at any node of 0.073 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 13.2 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 59.39 psi with a flow of 33.44 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Ell Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) H T L C B G A D Ell Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 2.050 8.00 15.00 3.00 17.00 9.00 2.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE 9/20Y2021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE TWO HEAD CALC PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE:' 9/202021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE TWO HEAD CALC WATER SUPPLY ANALYSIS Static: 59.40 psi Resid: 58.00 psi Flow: 500.0 gpm E:I,wI1 70.0 LEGEND 60.0 G 1 A 2 U G 50.0 E P 40.0 R H S 30.0 S U R 20.0 E Available pressure 59.39 psi @ 32.0 gpm Required pressure 56.27 psi 8 32.0 gpm Source Supply Curve System Demand Curve p 10.0 5 i 0.0 -14.7 100150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE 9/20/2021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE TWO HEAD CALC WATER SUPPLY CURVE 600\\\\\\\\ I \\\\\\\\\ I * <-58.0 psi 8 500 gpm X Flow Test Point 55+ 50+ 45+ P 40+ R I E I S I S 35+ U R I E I 30+ P S I 25+ 20+ 15+ 10+ LEGEND I 'I I X = Required Water Supply I 56.27 psi 8 32.0 gpm 5+ It I 0 = Available Water Supply It I 59.39 psi @ 32.0 gpm It 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) #7# Z ffL7/If.. 12155 PAINE PLACE POWAY, CA 92064 HYDRAULIC CALCULATIONS FOR TELESCOPE AVENUE RESIDENCE FILE NUMBER: 21-0704.SDF DATE: SEPTEMBER 20, 2021 -DESIGN DATA- OCCUPANCY CLASSIFICATION: RESIDENTIAL DENSITY: .05 gpm! 400 sq.ft. AREA OF APLICATION: CLOSET COVERAGE PER SPRINKLER: 400 sq.ft. NUMBER OF SPRINKLERS: 1 SPRINKLER TOTAL SPRINKLER WATER FLOW REQUIRED: 21.0 gpm TOTAL WATER REQUIRED (including hose): 26.0 gpm FLOW AND PRESSURE (@BOR): 21.0 gpm @ 30.4 psi SPRINKLER ORIFICE SIZE: 1/2" inch NAME OF CONTRACTOR: SYMONS FIRE PROTECTION, INC. DESIGN! LAYOUT: FRANCISCO IBARRA AUTHORITY HAVING JURISDICTION: CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C16-682025 WATER DEPARTMENT: CARLSBAD WATER DEPARTMENT CONTACT: GINA WATER PRESSURE INFORMATION: 66.0 psi STATIC CALCULATIONS BY HASS COMPUTER PROGRAM (LICENSE #38071930) HRS SYSTEMS, INC. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 1 DATE 9/20/2021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE ONE HEAD CALC WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. 8 PRESS. 8 DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) 1 59.4 58.0 500.0 59.4 26.0 58.7 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 26.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 0.0 GPM OTHER HOSE STREAM ALLOWANCES 5.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 21.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 -2.0 SOURCE 58.7 26.0 2 0.0 - - - - 50.5 - - - 3 0.0 - - - - 37.5 - - - 4 10.0 - - - - 32.9 - - - 5 12.0 HOSE STREAM 30.4 5.0 6 20.5 - - - - 24.4 - - - 7 20.5 - - - - 22.6 8 24.5 - - - - 19.3 8A 24.0 - - - - 19.5 - - - 9 27.0 - - - - 18.0 - - - 9A 26.5 - - - - 18.2 - - - 10 20.5 - - - - 20.2 - - - bA 20.0 K= 4.90 18.4 21.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATES 9/2072021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOE TITLE: TELESCOPE AVENUE RESIDENCE ONE HEAD CALC PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 26.0 0.995 PL 30.00 PF 7.3 1 -2.0 SRCE 58.7 (N/A) 10.7 150 FTG TLG PE -0.9 2 0.0 0.0 50.5 0.0 0.181 TL 40.50 PV Pipe: 2 FIXED PRESSURE LOSS DEVICE 2 0.0 0.0 50.5 0.0 13.0 psi, 26.0 gpm 3 0.0 0.0 37.5 0.0 Pipe: 3 26.0 2.050 PL 55.00 PF 0.3 3 0.0 0.0 37.5 0.0 2.5 150 FTG 2L PE -4.3 4 10.0 0.0 32.9 0.0 0.005 TL 61.00 PV Pipe: 4 26.0 1.025 FL 5.00 PF 1.6 4 10.0 0.0 32.9 0.0 10.1 150 FTG EL PE -0.9 5 12.0 H.S. 30.4 5.0 0.157 TL 10.00 PV Pipe: 5 21.0 1.101 PL 8.00 PF 2.3 5 12.0 H.S. 30.4 5.0 7.1 150 FTG 2ET3RC PE -3.7 6 20.5 0.0 24.4 0.0 0.074 TL 31.00 PV Pipe: 6 21.0 1.101 PL 10.00 PF 1.9 6 20.5 0.0 24.4 0.0 7.1 150 FTG 2ER PE 0.0 7 20.5 0.0 22.6 0.0 0.074 TL 25.00 PV Pipe: 7 9.4 1.101 PL 55.00 FE' 1.6 7 20.5 0.0 22.6 0.0 3.2 150 FTG 3E3TR FE -1.7 8 24.5 0.0 19.3 0.0 0.017 TL 92.00 PV Pipe: 8 0.0 1.101 PL 0.50 PF 0.0 8 24.5 0.0 19.3 0.0 0.0 150 FTG TR PE 0.2 8A 24.0 0.0 19.5 0.0 0.000 TL 6.50 PV Pipe: 9 9.4 1.101 PL 10.00 PF 0.2 8 24.5 0.0 19.3 0.0 3.2 150 FTG R PE -1.1 9 27.0 0.0 18.0 0.0 0.017 TL 11.00 PV Pipe: 10 0.0 1.101 PL 0.50 FE' 0.0 9 27.0 0.0 18.0 0.0 0.0 150 FTG TR FE 0.2 9A 26.5 0.0 18.2 0.0 0.000 TL 6.50 PV Pipe: 11 9.4 1.101 PL 19.50 PF 0.6 9 27.0 0.0 18.0 0.0 3.2 150 FTG 2E2R PE 2.8 10 20.5 0.0 20.2 0.0 0.017 TL 35.50 PV Pipe: 12 21.0 1.101 PL 14.00 PF 2.1 10 20.5 0.0 20.2 0.0 7.1 150 FTG ET2R PE 0.2 bA 20.0 4.9 18.4 21.0 0.074 TL 28.00 PV Pipe: 13 -11.6 1.101 FL 73.00 PP 2.3 10 20.5 0.0 20.2 0.0 3.9 150 FTG 2E8R PE 0.0 7 20.5 0.0 22.6 0.0 0.025 TL 95.00 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 9/20/2021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE ONE HEAD CALC NOTES (BASS) Calculations were performed by the HASS 8.8 D computer program in accordance with NFPA13 (2019) under license no. 38071930 granted by HRS Systems, Inc. 208 Southside Square Petersburg, TN 37144 (931) 659-9760 The system has been calculated to provide an average imbalance at each node of 0.001 gpm and a maximum imbalance at any node of 0.010 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 10.7 ft/sec at pipe 1. Items listed in bold print on the cover sheet are automatically transferred from the calculation report. Available pressure at source node 1 under full flow conditions is 59.39 psi with a flow of 26.21 gpm. PIPE FITTINGS TABLE User Pipe Table Name: FSS.PIP PAGE: H MATERIAL: CPVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T R K C L B L Eli Tee TEERUN COUPLG EL45 1.101 7.00 5.00 1.00 0.00 1.00 1.00 0.00 1.00 PAGE: I MATERIAL: CPPR-L HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 1.025 3.00 8.00 2.00 8.00 2.00 2.00 0.00 0.00 PAGE: J MATERIAL: S40PVC HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee 2.050 8.00 15.00 3.00 17.00 9.00 2.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 9/20/2021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE ONE HEAD CALC PAGE: K MATERIAL: CPPR-K HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D Eli Tee L 0.995 2.00 6.00 1.50 0.00 0.00 3.00 0.00 0.00 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 9/202021 C:\PROGRAM FILES\HRS SYSTEMS\HASS87\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE ONE HEAD CALC WATER SUPPLY ANALYSIS Static: 59.40 psi Resicl: 58.00 psi Flow: 500.0 gpm 70.0 LEGEND Available pressure 60.0 G A U G 50.0 E P 40.0 R E 30.0 S U R 20.0 E 59.39 psi @ 26.0 gpm Required pressure 58.72 psi 8 26.0 gpm Source Supply Curve System Demand Curve p 10.0 S i 0.0 -14.7 100150 200 250 300 350 400 450 500 FLOW (GPM) Note: (1) Dashed Lines indicate extrapolated values from Test Results SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 9/20/2021 C:\PROGRAN FILES\HRS SYSTEMS\HA5587\HASS DATA\21-0704.SDF JOB TITLE: TELESCOPE AVENUE RESIDENCE ONE HEAD CALC WATER SUPPLY CURVE 600\\\\\\\\ x \\\\\\\\\ I * <-58.0 psi @ 500 gpm I Flow Test Point 55+ 50+ 45+ P 40+ R I F I S I S 35+ U I R I E I 30+ P I S I 25+ 20+ 15+ 10+ LEGEND I' X = Required Water Supply I 58.72 psi 8 26.0 gpm 5+ I 0 = Available Water Supply I 59.39 psi @ 26.0 gpm 0++-+---+----+-----+------+--------+--------+---------+-----------+ 200 300 400 500 600 700 800 900 1000 FLOW (GPM) 7r Model RFC30 & RFC30LL Model RFC43 & RFC43LL Model RFC49 & RFC49LL Model RFC58 Bulletin 006 January 2020 ReIiabI Model RFC Series Residential Sprinklers Flat Concealed Pendent cULus Listed Features cULus Listed as Residential Sprinklers Push-On cover plate installation Low water flow requirements Product Description Model RFC Series residential sprinklers are flat cover plate, concealed pendent sprinklers intended for installation in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sprinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sprinklers are cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL) and Australian WaterMark Certified (WMCS). Model RFC30 sprinklers have a 165°F (74°C) temperature rated fusible-link operating element. Model RFC43, RFC49, RFC58, and RFC76 sprinklers are offered with either a 165°F (74°C) or 212°F (100°C) temperature rated fusible-link oper- ating element. Sprinklers with a 165°F (74°C) temperature rating are ordinary temperature classification and are listed for use with a 135°F (57°C) temperature rated cover plate. Sprinklers with a 212°F (100°C) temperature rating are inter- mediate temperature classification and are listed for use with a 165°F (74°C) temperature rated cover plate. Model RFC Series sprinklers are installed with a Model RFC or Model G5 Cover Plate. Model G5 Cover Plates may be installed by either pushing or threading the cover plate into the sprinkler cup. Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49 and RFC49LL sprinklers allow 1/2" (13 mm) of cover plate adjustment. Model RFC58 and RFC76 sprinklers allow 3/4" (19 mm) of cover plate adjustment. Model RFC and G5 Cover Plates are available in a variety of finishes as listed in Table H. Model RFC76 Model RFC & G5 Cover Plate Table A Sprinkler Model Nominal K-Factor gpm/psi112(1/min/bar112) Max. Coverage Area ft x ft (m x m) Listings & Approvals Sprinkler Identification Number (SIN) RFC30 3.0(43) 14x 14(4.3x4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14(4.3 x 4.3) cULus, LL, WMCS RA3211 RFC43 4.3(62) 20x20(6.1 x6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3212 RFC49 4.9(71) 20x20(6.1 x6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus, LL, WMCS RA3216 RFC58 5.8(84) 20x20(6.1 x6.1) cULus RA0613 RFC76 7.6(109) 20 x 20(6.1 x 6.1) cULus RA0618 cULus: cULus Listed to UL1626, Residential Sprinklers for Fire Protection Service. LL: cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (Less than 0.25% Lead content). WMCS: Australian WaterMark Certified. www.reliablesprinkler.com Model G4/G5 Cover Plate Ceiling Model RFC30 & RFC30LL Sprinkler Components and Dimensions Threads Body - Cup - Tower - Fusible Link Deflector (retracted) Pin (extended) - Deflector (extended) - 2-5/16(58 mm) Dia. 1-3/4(44 mm) +1- 1/4(6 mm) Nominal face of fitting to ceiling 3/16 (5 mm) Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Rating 165°F (74°C) sprinkler 135°F (57°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC30LL only) Watermark Certified (RFC30LL only) Bottom View Model RFC30 and RFC30LL Sprinkler Hydraulic Design Criteria M."al F1111: Minimum Flow and Residual Pressure (1) Max. Coverage Area () Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 12x12 9 9.0 (3.6 x 3.6) (34) (0.62) 14x14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table B above and (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 2 of 8 January 2020 flellabld www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.3 (62 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model RFC Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Bottom View Listings and Approvals Cover Plate Finishes cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC43LL only) Watermark Certified (RFC43LL only) Model RFC43 & RFC43LL Sprinkler Components and Dimensions 2-5/16(58 mm) Threads Dia. Body Cup Tower 1-3/4 (44 mm) +/- 1/4 Fusible Link I Nominal face of fitting to ceiling Deflector (retracted) 3/16 (5 mm) Pin (extended) I H Deflector (extended) Ceiling \.__ Model G4/G5 Cover Plate 3-5/16 (84 mm) Dia. Model RFC43 & RFC43LL Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) Ordinary Temperature ___________________ Intermediate Temperature Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 15x15 12 7.8 12 7.8 (4.6 x 4.6) (45) (0.54) (45) (0.54) 16x16 13 9.1 13 9.1 (4.9 x 4.9) (49) (0.63) (49) (0.63) 18x18 18 17.5 (5.5x5.5) (68) (1.21) -- -- 20x20 21 23.8 (6.1 x6.1) (79) (1.64) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table C above and (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 3 of 8 January 2020 www.reliablesprinkler.com Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Sensitivity Fast-response Temperature Rating Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (1 00°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) I .?- Bottom View Cover Plate Finishes Listings and Approvals cULus Listed to UL 1626 (See Table H) cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G (RFC49LL only) Watermark Certified (RFC49LL only) Model RFC49 & RFC49LL Sprinkler Components and Dimensions 2-5/16(58 mm) Threads Dia. Body Cup ____________ Tower 1-3/4 (44 mm) +1- 1/4(6 mm) ______ 3/16(5mm) Fusible Link Nominal face of fitting to ceiling Deflector (retracted) Pin (extended) Deflector (extended) Model G4/G5 Cover Plate 3-5/16 (84 mm) Dia. V, Ceiling Model RFC49 & RFC49LL Sprinkler Hydraulic Design Criteria rn;irii Minimum Flow and Residual Pressure (1) Max. Coverage Area (2) Ordinary Temperature Intermediate Temperature __________________ Flow Pressure Flow Pressure ft. x ft. (m x m) gpm psi gpm psi (I/mm) (bar) (I/mm) (bar) 16x16 13 7.0 13 7.0 (4.9 x 4.9) (49.0) (0.48) (49.0) (0.48) 18x18 17 12.0 17 12.0 (5.5 x 5.5) (64.3) (0.83) (64.3) (0.83) 20x20 20 16.7 21 18.4 (6.1 x6.1) (75.7) (1.15) (79.5) (1.27) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table D above and (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 4 of 8 January 2020 flellabi www.reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 1/2" NPT or ISO 7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Chrome Plated Bronze Alloy Cup: Steel Cover Plate Finishes (See Table H) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC58 Sprinkler Components and Dimensions Threads - Body Cup Tower - Fusible Link - Deflector (retracted) Pin (extended) Deflector (extended) 1-7/8 (48 mm) +1- 3/8(9 rr Nominal face of fitting to cei Model G4/G5 Cover Plate 3/16(5 mm) eiling Model RFC58 Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure 1 Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18x18 18 9.6 (5.5x5.5) (68.1) (0.66) 20x20 20 11.9 (6.1 x6.1) (75.7) (0.82) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table E above and (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 January 2020 www.reliablesprinkler.com 5 of 8 reliablesprinkler.com Bottom View Technical Specifications Style: Flat Concealed Pendent Threads: 3/4" NPT or ISO 7-1 R3/4 Nominal K-Factor: 7.6 (109 metric) Max. Working Pressure: 175 psi (12 bar) Mm. Spacing: 8 ft. (2.4 m) Material Specifications Thermal Sensor: Nickel Alloy Solder Link Sprinkler Body: Brass Alloy Levers: Bronze Alloy Yoke: Brass Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Towers: Copper Alloy Pins: Stainless Steel Deflector: Bronze Alloy Cup: Steel Cover Plate Finishes (See Table I-I) Sensitivity Fast-response Temperature Ratings Ordinary: 165°F (74°C) sprinkler 135°F (57°C) cover plate Intermediate: 212°F (100°C) sprinkler 165°F (74°C) cover plate Cover Plate Model G5 Cover Plate Sprinkler Wrench Model FC (without wrench-able cap) Model W3 (with wrench-able cap) Listings and Approvals cULus Listed Model RFC76 Sprinkler Components and Dimensions 2-5/16 (58 mm) Three Body Cup Towei Fusible Li Deflector (retrs Pin (exten Deflector (extend Dia. 1-7/8 (48 mm) 3/8 (9 mm) Nominal face of fitting to ceiling +1- '''''''4 3/16° (5 mm) ,,,,,,, r_ Model G4/G5 Cover Plate -' 3-5/16 (84 mm) Dia Ceiling Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressuret1 Max. Coverage Area (2) Flow Pressure ft. x ft. gpm psi (m x m) (I/mm) (bar) 16x16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18x18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20x20 34 20 (6.1x6.1) (128.7) (1.4) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in Table E above and (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 006 Page 6 of 8 January 2020 www.reliablesprinkler.com Cover Plate Finishes(') Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. Custom color paint is semi-gloss, unless specified otherwise. Stainless steel clad cover plates are Type 316 Stainless Steel on the finished side and C102 Copper Allow on the backside. Cover plates are not listed or approved as corrosion resistant. Installation Dimensions Recommended Mm. to Mm. to Max. Sprinkler Cover Cover Plate Hole Diameter Cover Plate Max. Face Dropped Deflector Cover Plate Model Plate Diameter in Ceiling Adjustment of Fitting to Distance below Temperature Model inch (mm) inch (mm) inch (mm) Ceilingt1t Ceiling Rating inch (mm) inch (mm) RFC30, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC30LL G5 (84) (67) (13) (38t051) (13t025) (57°C) RFC43, 135°F2 RFC43LL, RFC or 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 (57°C) RFC49, G5 (84) (67) (13) (38 to 51) (13t025) or 1650F3 RFC49LL (74°C) 135°F2 RFC58, RFC or 3-5/16 2-5/8 3/4 1-1/2t02-1/4 1/4to1 (57°C) RFC76 G5 (84) (67) (19) (38 to 57) (6 to 25) or 1650F13 Notes: Face of fitting to ceiling dimensions are based on a nominal thread make up. Verify dimensions based on fitting and thread sealing method prior to installation. A 1/2" x 1/2" brass nipple extension (Reliable P/N 6999991900) is available where necessary for replacement of existing sprinklers. For use with 165°F (74°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 100°F (380C). For use with 212°F (100°C) temperature rated sprinklers where the Maximum Ceiling Temperature does not exceed 150°F (660C). Installation Model RFC series sprinklers are intended to be installed in accordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the requirements of applicable authorities having jurisdiction. Model RFC series sprinklers must not be installed in ceilings with positive pressure in the space above. Ensure that the 4 slots in the cup are open and unobstructed following installation. Model RFC series sprinklers are shipped with a wrench-able protective cap that should remain on the sprinkler until the sprinkler system is placed in service following construction. Model RFC series sprinklers can be installed without removing the wrench-able protective cap using the Model W3 wrench. Alternatively, Model RFC series sprinklers can be installed using the Model FC wrench by temporarily removing the protective cap during installation of the sprinkler. The use of any other wrench to installed Model RFC series sprinklers is not permitted and may damage the sprinkler. Fully insert the Model W3 wrench over the cap until it reaches the bottom of the cup, or the Model FC wrench over the sprinkler until the wrench engages the body. Do not wrench any other part of the sprinkler/cup assembly. The Model W3 and FC wrenches are designed to be turned with a standard 1/2" square drive. Tighten the sprinkler into the fitting after applying a PTFE based thread sealant to the sprinkler's threads. Recommended installation torque is 8 to 18 ft-lbs (11 to 24 N-m) for 1/2" thread sprinklers and 14 to 20 ft-lbs (19 to 27 N-m) for 3/4" thread sprinklers. Bulletin 006 January 2020 Do not exceed the maximum recommended torque. Exceeding the maximum recommended torque may cause leakage or impairment of the sprinkler. Use care when inserting or removing the wrench from the sprinkler to avoid damage to the sprinkler. Install the cover plate by hand by pushing the cover plate into the cup and turning the cover in the clockwise direction until it is tight against the ceiling. Application Model RFC series sprinklers are intended for installation where residential sprinklers are permitted or required by NFPA 13, NFPA 13R, and NFPA 13D. The sprinklers are concealed pendent residential sprinklers. Model RFC 30 and RFC30LL sprinklers are available in ordinary temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (380C). Model RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are available in either ordinary or intermediate temperature classification for installation where the Maximum Ceiling Temperature does not exceed 100°F (38°C) or 150°F (66°C), respectively. Page 7 of 8 www.reliablesprinkler.com Model FC Model W3 For use with Model RFC Series sprinklers For use with Model RFC Series sprinklers without wrench-able cap installed with wrench-able cap installed Maintenance Model RFC series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Replace any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replace- ment of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-oper- ation. Listings and Approvals Listed by Underwriters Laboratories, Inc. and UL Certified for Canada to UL1626, Residential Sprinklers for Fire-protection Service (cULus). Certified by Underwriters Laboratories, Inc. and Underwrit- ers Laboratories of Canada for Health Effects to NSF/ANSI Standard 61 Annex G (LL) (RFC30LL, RFC43LL, and RFC49LL only). Australian WaterMark Certified (RFC30LL, RFC43LL, and RFC49LL only). Guarantee For the Reliable Automatic Sprinkler Co., Inc. guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents Model RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, and RFC76 sprinklers are covered by U.S. Patent No. 9,248,327 and U.S. Patent No. 7,275,603. Model RFC30, RFC30LL, RFC43 and RFC43LL sprinklers are additionally covered by U.S. Patent No. 8,776,903. Ordering Information Specify the following when ordering. Sprinkler Model (RFC30, RFC30LL, RFC43, RFC43LL, RFC49, RFC49LL, RFC58, RFC76) Temperature Rating Cover Plate Model RFC or G5 Temperature Rating Finish (See Table H) Sprinkler Wrench Model FC Model W3 Bulletin 006 1 Page 8 of 8 January 2020 Reliabld www.reliablesprinkIer.com '4 Bulletin 135 October 2019 ReIiabI Features cULus Listed Residential Sprinklers Available in pendent and horizontal sidewall orientations Decorative finishes available, including recessed escutch- eons and conical concealed cover plates Product Description Model F1 Res Series sprinklers are residential sprinklers with a 3 mm glass bulb operating element. A variety of K-Factors as well as recessed and conical concealed options are available as detailed in this Bulletin. The FiRes Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Application The Model FiRes Series sprinklers cULus Listed Residential sprinklers are intended for use in accordance with NFPA 13, NFPA 13R, or NFPA 13D. The Model FiRes residential sprin- klers are cULus Listed for use in residential occupancies and residential portions of any occupancy, where permitted by NFPA 13, NFPA 13R, or NFPA 13D. For NFPA 13R and NFPA 13D applications, the design flow and pressure shall not be less than the minimum flow and pressure specified in the Listed Model Fl Res Series Glass Bulb Residential Sprinklers cULus Listed Design Criteria tables in this Bulletin. For NFPA 13 applications, the design density shall be a minimum of 0.1 gpm/sf (4.1 mm/ mm), but in no case shall the flow and pressure be less than the minimum flow and pressure specified in the Listed Design Criteria tables in this bulletin. Model Fl Res Series sprinklers are listed for use in wet systems only. Residential Sprinkler Summary Sprinkler Sprinkler Identification Orientation K-Factor gpm/psi112 Thread Size Installation Options Max. Coverage Area Model Number (SIN) (lpm/bar1 ) NPTorlSO7-1 ftxft(mxm) F1Res30 R3511 Pendent 3.0(43) 1/2 Pendent or Recessed 16 x16 (4.9 x 4.9) FiRes49 R3516 Pendent 4.9(71) 1/2 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res58 R3513 Pendent 5.8(84) 1/2 Pendent or Recessed 20x20(6.1 x6.1) F1Res76 R7618 Pendent 7.6(109) 3/4 Pendent or Recessed 20 x 20(6.1 x 6.1) F1Res3OCCP R3511 Pendent 3.0(43) 1/2 Conical Concealed or Recessed 14 x 14(4.3 x 4.3) F1Res49CCP R3516 Pendent 4.9(71) 1/2 Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res58 CCP R3513 Pendent 5.8(84) 1/2 Conical Concealed or Recessed 20 x 20(6.1 x 6.1) F1Res76 CCP R7618 Pendent 7.6(109) Conical Concealed or 20x20(6.1 x6.1) Recessed F1Res44 HSW R3531 Horizontal Sidewall 4.4(63) 1/2 Recessed 16 x 20(4.9 x 6.1) F1Res44SWC R3531 Horizontal Sidewall 4.4(63) 1/2 Conical Concealed 16 x 20 (4.9 x 6.1) F1Res58 HSW R3533 Horizontal Sidewall 5.8(84) 1/2 Recessed 16 x 20(4.9 x 6.1) F1 Res 58 HSWX RA3533 Horizontal Sidewall 5.8 (84) 1/2 Recessed 14 x 26 (4.3 x 7.9) www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2' NPT or IS07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 175°F (79°C) Material Specifications Thermal Sensor: 3 mm glass bulb Recessed Escutcheons Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res30 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4" (57mm) DlA. -r Face of fitting (49mm) DIA. ceiling 1/2" (13mm) _______ +1- 1/4" (6mm) Wrench Flat 1-15/16" to finished Threads ____________ 03SV Sealing Assembly __________ _____________________ Load Screw 2-1/4" I I7Z1 Glass Bulb (57mm) 1-3/4" (44mm) 1/4" (6mm) Deflector +1- (32mm) 2-7/8" (72mm) DIA. Components Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res30 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(e Maximum Coverage Area2 Flow gpm (I/mm) ft. x ft.(m x m) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12 (3.7 x 3.7) 8 (30) 7.0 (0.48) 1 t 4 inches (25 to 100 mm) 14 X 14(4.3 X 4.3) 10(38) 11.0 (0.76) 15 x 15(4.6 x 4.6) 12(45) 16.0(1.1) 16x 16 (4.9x4.9) 13(49) 18.8(l.3) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 2 of 15 October 2019 www.reliablesprinkler.com Technical Specifications Finishes Style: Pendent and Recessed Pendent (See Table N) Threads: 1/2" NPTor 1S07-1R1/2 Temperature Ratings Nominal K-Factor: 4.9 (71 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed Escutcheons Thermal Sensor: 3 mm glass-bulb Fl Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model Fl Res49 Residential Pendent Sprinkler Components and Installation Dimensions [EITT' 2-1/4" (57mm) 2-1/4" (57mm) DIA. Face of fitting DIA. Face of fitting 1-15/16" to finished 1-15/16" to finished (49mm) DIA. ceiling (49mm) DIA. ceiling 5/8" (16mm) 1/2(13mm) +1-3/8(9mm) I +1- 1/4(6mm) I1-1/4 (32mm) Dimnsinns Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1Res49 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemstl) Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 13(49) 7.0(0.48) 1 t 4 inches (25 to 100 mm) 14 x 14 (4.3 x 4.3) 13 (49) 7.0(0.48) 16 x 16 (4.9 x 4.9) 13(49) 7.0(0.48) 18 x 18(5.5 x 5.5) 17(64) 12.0(0.83) 20 x 20 (6.1 x 6. 1) 20(76) 16.7(1.15) 12 x 12(3.7 x 3.7) 15 (57) 9.4 (0.65) 4 to 8 inches (100 to 200 mm) 14 x 14(4.3 x 4.3) 16(61) 10.7 (0.74) 16 x 16(4.9 x 4.9) 17(64) 12.0 (0.83) 18x 18(5.5x5.5) 19(72) 15.0 (1.03) 20 x 20(6.1 x 6.1) 22(83) 20.2(1.39) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 3 of 15 October 2019 www.reIiablesprinkler.com 7/8" (72mm) DIA 1-5/8(41mm) +/- 3/6(9mm) 1-3/4" 1/4" 2-7/8" (72mm) DIA. Technical Specifications Style: Pendent and Recessed Pendent Threads: 1/2" NPT or 1S07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons Fl Recessed F2 Recessed FV Recessed* Sprinkler Wrenches Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model 171Res58 Residential Pendent Sprinkler Components and Installation Dimensions 2-1/4 (57mm) 2-1/4" (57mm) -r-- DIA. 1-15/16' to finished ceiling 4(49 ceiling to finished 5/8 (16mm)1/2 (13mm) (49mm) Face of fitting Face of fitting ________ ________ 1-3/4" (41mm) 3/8(9mm)+/- 1/4(6mm) __ ___-5/8' (41mm) +1- "(6mm) 3/8(9mm) 2-7/8' (72mm) DIA. 2-7/8'(l2mm)D. 1/4 ______________________ 174"I I 32mm) Dimensions Fl Recessed Escutcheon Installation F2 & FV Recessed Escutcheon Installation Model F1Res58 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems111 Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6(0.52) 1 to 4 1 inches (25 to 00 ) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20 x 20(6.1 x 6.1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2)the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. October Bulletin 135 lg www.reliablesprinkler.com 4 of 15 liablesprinkler.com Finishes Technical Specifications (See Table N) Style: Pendent and Recessed Pendent Threads: 3/4' NPT or 1S07-1 83/4 Temperature Ratings Nominal K-Factor: 7.6(109 metric) 155°F (68°C) Max. Working Pressure: 175 psi (12 bar) 175°F (79°C) Material Specifications Recessed. Escutcheons Thermal Sensor: 3 mm glass bulb El Recessed Sprinkler Frame: Brass Alloy F2 Recessed Button: Copper Alloy FV Recessed* ( Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model W2 Model GFR2 (Recessed) * Model FV escutcheons are not for use in positively pressurized ceiling plenums. Model F1Res76 Residential Pendent Sprinkler Components and Installation Dimensions 4(49mm) DIA. Face of fithng DIA Face of fitting 1 15/16 to finished 115/16 to finished ceiling ceiling 5/8 (16mm) 1/2(13mm) 3/8 (9mm)+/- 1/4" (6mm) (mm) 2-1/4" (57mm) 2-1/4' (57mm) 2-1/4" 1/4(6mm) 7) L- "mm 2718 (72mm) DIA. 1 1-5/8(41mm) +1- (44mm) -2-7/8" (72mm) DIA 3/8 Dimensions Fl Recessed Escutcheon Installation F2 & P1 Recessed Escutcheon Installation Model F1Res76 Residential Pendent Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 18 x 18 (5.5 x 5.5) 21(80) 7.6 (0.52) 1 to 4 inches (25 to 100 mm) 20 x 20 (6.1 x 6.1) 23 (87) 9.2 (0.63) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 5 of 15 October 2019 Reliable www.reliablesprinkler.com Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2 NPT or 1S07-1R1/2 Nominal K-Factor: 3.0 (43 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)° FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and COP cover plates are not listed for use in positively pressurized ceiling plenums. Model F1Res30 CCP and FP Recessed Pendent Sprinkler Installation Dimensions 9ç/p' (7,,rn\ O/O iC7n ace of fitting to finished ceiling -1/4 (32mm) I- 1/4(6mm) 15/16 (24mm) ace of fitting to finished ceiling -1/4 (32mm) I- 1/4"(6mm) 1(25mm) /- 1/4(6mm) CCP Recessed Escutcheon Installation FP Recessed Escutcheon Installation Model Fl Res30 CCP Pendent & FP Recessed Pendent Sprinkler Hydraulic Desiqn Criteria Table F Minimum Flow and Residual Pressure in Wet Pipe Systems") Maximum Coverage Area(2) Flow I Pressure I Deflector to Ceiling Distance ft. x ft. (m x m) gpm (I/mm) psi (bar) 12 X 12(3.7 X 3.7) 8(30) 7.0 (0.48) 1/2 to 1 inch (13 to 25 mm) 14 x 14(4.3 x 4.3) 11(38) 13.4(0.92) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 6 of 15 October 2019 Hellabld reliablesprinkler.com Face of fitting to finished ceiling 1-1/4' (32mm) +1- 1/4" (6mm) 1" (25mm) +1- 1/4" (6mm) ace of fitting to finished ceiling 1/4" (32mm) 1/4" (6mm) 15/16' (24mm) -_3-3/16" (78mm) DIA. FP Recessed Escutcheon Installation ',c/n" (7n,rv\ CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2' NPT or lS07-1R1/2 Nominal K-Factor: 4.9 (71 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model F1Res49 CCP & FP Recessed Pendent Sprinkler Installation Dimensions jJTJE Model Fl Res49 CCP Pendent and FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 14 x 14(4.3 x 4.3) 13 (49) 7.0(0.48) 1/2 to 1 inch (13 to 25 mm) 16.7(1.15) 16 X 16(4.9 X 4.9) 14(53) 8.2 (0.57) 18 x 18 (5.5 x 5.5) 18 (68) 13.5 (0.93) 20 x 20 (6.1 x 6. 1) 20(76) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 7 of 15 October 2019 Rellabld www.reliablesprinkler.com CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 1/2" NPTorlSO7-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (570C)* FP Recessed* Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and CCP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res58 CCP and FP Recessed Pendent Sprinkler Installation Dimensions T11 2-5/8(67mmL 2-5/16" (59mm)DIA. ace of fitting I Face of fitting to finished ________________________________ _______________________________ to finished ceiling ceiling -1/4' (32mm) /- 1/4(6mm) ________ 1-1/4' (32mm) 1/4" (6mm) (24mm) +/-1/4"(6rnm) L3-3/1\6' (78m m) DIA. - FPRecessedEscutcheonInstallation Model F1Res58 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria 8111:1 1. Minimum Flow and Residual Pressure in Wet Pipe Systems(') Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 16 x 16(4.9 x 4.9) 16(61) 7.6 (0.52) 1/2 to 1 inch (13 to 25 mm) 18 x 18(5.5 x 5.5) 19(72) 10.8 (0.75) 20 x 20 (6.1 x 6. 1) 22(83) 14.4(1.0) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 Page 8 of 15 October 2019 Reliabld www.reliablesprinkler.com :ace of fitting to finished ceiling 1/4" (32mm) /- 1/4(6mm) 1(25mm) /- 1/4"(6mm) ace of fitting to finished ceiling -1/4 (32mm) /- 1/4(6mm) 15/16 (24mm) 9c/n" FP Recessed Escutcheon Installation )/o CCP Recessed Escutcheon Installation Technical Specifications Style: Conical Concealed Pendent and Recessed Pendent Threads: 3/4" NPT or IS07-1R3/4 Nominal K-Factor: 7.6(109 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) Recessed Escutcheons/Cover Plates CCP Conical Concealed Plate 135°F (57°C)" FP Recessed" Sprinkler Wrenches Model GFR2 (Recessed) *Note: Model FP escutcheons and COP cover plates are not for use in positively pressurized ceiling plenums. Model Fl Res76 CCP and FP Recessed Pendent Sprinkler Installation Dimensions Model F1Res76 CCP Pendent & FP Recessed Pendent Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems1 Maximum Coverage Aream Flow Pressure Deflector to Ceiling Distance ft. x ft. (m x m) gpm (I/mm) psi (bar) 16 x 16 (4.9 x 4.9) 21(80) 7.6 (0.52) 1/2 to 1 inch (13 to 25 mm) 10.8 (0.75) 18 x 18 (5.5 x 5.5) 22 (83) 8.4 (0.58) 20 x 20(6.1 x 6.1) 25(95) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. The sprinkler must be installed into a ceiling with the listed cover plate installed. Bulletin 135 jiiI Page 9 of 15 October 2019 www.reliablesprinkler.com Finishes (See Table N) Temperature Ratings 155°F(68°C) / / 175°F(79°C) F Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or 1S07-1R1/2 Nominal K-Factor: 4.4 (63 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Model Fl Res44 Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 5/8(41mm) 3/8(10mm) +1- 1/4" (6mm) 2-7/16" (62mm) V1 7"1,). (8mm) 2-1/4" 1-15/16" (57mm) (49mm) DIA. DIA. Top of Deflector Down from - - ceiling to be Either 4" to 6" (100 to 150 mm) or 6" to 12 (150 to 300 mm) Based on Hydraulic Calculations F2 & FV Recessed Escutcheon Installation Model F1Res44 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst1t - Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 12(45) 7.5 (0.52) (1 inches 50 mm) 14 x 14(4.3 x 4.3) 14(53) 10.2 (0.70) 15 x 15(4.6 x 4.6) 15(57) 11.6(0.80) 16 x 16(4.9 x 4.9) 16 (61) 13.3 (0.92) 16 x 18 (4.9 x 5.5) 18(68) 16.8(1.16) 16 x 20(4.9 x6.1) 23(87) 27.4(l.89) 18 x 18(5.5 x 5.5) 19(72) 18.7(l.29) 12 x 12(3.7 x 3.7) 14(53) 10.2 (0.7) 6 to 12 inches (150 to 300 mm) 27.4(l 89) 14x 14(4.3x4.3) 16(61) 13.2(0.91) 15 x 15(4.6 x 4.6) 16(61) 13.2(0.91) 16 x 16(4.9 x 4.9) 17(64) 15.0(1.03) 16 x 18(4.9 x 5.5) 20(76) 20.7(l.43) 16 x 20 (4.9 x 6.1) 23 (87) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 10 of 15 October 2019 RellabIld www.reliablesprinkler.com Technical Specifications Finishes Style: Conical Concealed Sidewall (See Table N) Threads: 1/2" NPT or ISO 7-1 R1/2 Nominal K-Factor: 4.4 (63 metric) Temperature Ratings Max. Working Pressure: 175 psi (12 bar) 155°F (68°C) 1751F(79°C)>1> Material Specifications Thermal Sensor: 3 mm glass-bulb Cover Plates SWC Sprinkler Frame: Brass Alloy SWC Conical Concealed Plate(2) Button: Copper Alloy SWC-2 (Slotted) Conical Concealed Plate (3) k. SWC-2 "P Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Sprinkler Wrenches Deflector: Bronze Alloy Model GFR2 Note: >"Not for installation where the maximum ceiling temperature exceeds 100°F due to cover plate temperature rating. >2>135°F SWC Conical Concealed Plate for 155°F (68°C) sprinklers >3>135°F SWC-2 (Slotted) Conical Concealed Plate for 175°F (79°C) sprinklers Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler and Installation Dimensions r (25mm) 1' (25mm) +/-1/4 (6mm) 1/4 (6mm) Face of fitting to finished wall 2-7/16' (62mm)-1 5/16" j (6mm) Dimensions 16DI T1 E(41 m m)]- SWC & SWC-2 Concealed Cover Plate Installation Top of Deflector Down I from ceiling to be Either 35/16' 4 to 6 (100mm to (84mm) 150mm) or 6' to 12 DIA. (150mm to 300mm) Based on Hydraulic Calculations I Model Fl Res44 SWC Conical Concealed Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst Maximum Coverage Area ft. x ft. (m x m) Ordinary Temperature Rating 155°F (68°C) Intermediate Temperature Rating 175°F (79°C) Deflector to Ceiling Distance psi (bar) Flow gpm (I/mm) Pressure psi (bar) Flow gpm (I/mm) Pressure 12 x 12 (3.7 x 3.7) 13 (49) 8.7 (0.60) 14 (53) 10.2 (0.7) 14 x 14(4.3 x 4.3) 14(53) 10.2 (0.7) 14(53) 10.2 (0.7) 4 to 6 inches 15 x 15(4.6 x4.6) 16(61) 13.2 (0.91) -- -- 16 x 16(4.9 x 4.9) 17(64) 15.0(1.03) -- -- (100 to 150 mm) 16 x 18(5.5 x 5.5) 19(72) 18.7(l.31) -- -- 16 x 20(4.9 x 6.1) 23(87) 27.4(1.89) -- -- 12 x 12(3.7 x 3.7) 14(53) 10.2 (0.7) -- -- 14 x 14(4.3 x 4.3) 15(57) 11.7 (0.81) -- -- 15x 15 (4.6x4.6) 17(64) 15.0(1.03) -- -- 6 to 12 inches (150 to 300 mm) 16 x 16 (4.9 x 4.9) 18(68) 16.8(1.16) -- -- 16x 18(4.9 x 5.5) 20(76) 20.7(1.43) -- -- Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1) the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 11 of 15 October 2019 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2" NPT or lS07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res58 Residential Horizontal Sidewall Sprinkler Installation Dimensions IuItI Face of fitting to finished wall 1-5/8" (41 mm) 3/8" (10mm) +1- 1/4(6mm) +1- 1/4" (6mm) 2-1/4' 1-15/16" (57mm) (49mm) DLA DIA. Top of Deflector Down from Ceiling to be Either 4" to 6" (100 to 150 mm) or 6 to 12" (150 to 300 mm) Based on Hydraulic Calculations (8mm) Dimensions F2 & P1 Recessed Escutcheon Installation Model F1Res58 Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systems(1) Maximum Coverage Area'' ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 12 x 12(3.7 x 3.7) 16(61) 7.6 (0.52) 4 to 6 inches (100 to 150 mm) 25.0(1.72) 14 x 14 (4.3 x 4.3) 18 (68) 9.7 (0.66) 15 X 15(4.6 X 4.6) 19(72) 10.7 (0.74) 16 x 16(4.9 x 4.9) 21(80) 13.2(0.91) 16 x 18(5.5 x 5.5) 25(95) 18.6(l.28) 16 x 20 (4.9 x 6. 1) 29(110) 12 x 12(3.7 x 3.7) 22(83) 14.4(1.0) 6 to 12 inches (150t0300mm) 28.6(l.97) 14 x 14(4.3 x 4.3) 22(83) 14.4(1.0) 15 x 15 (4.6 x 4.6) 24(91) 17.1 (1.18) 16 x 16(4.9 x 4.9) 26(98) 20.1 (1.39) 16 x 18 (4.9 x 5.5) 31 (117) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 12 of 15 October 2019 www.reliablesprinkler.com Technical Specifications Style: Sidewall and Recessed Sidewall Threads: 1/2' NPT or 1S07-1R1/2 Nominal K-Factor: 5.8 (84 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm glass bulb Sprinkler Frame: Brass Alloy Button: Copper Alloy Sealing Assembly: Nickel Alloy with PTFE Load Screw: Bronze Alloy Deflector: Bronze Alloy Finishes (See Table N) Temperature Ratings 155°F (68°C) 175°F (79°C) Recessed Escutcheons F2 Recessed FV Recessed Sprinkler Wrenches Model W2 Model GFR2 (Recessed) Model F1Res58 HSWX Residential Horizontal Sidewall Sprinkler Installation Dimensions Face of fitting to finished wall 1-7/8" (48mm) 3/8(10mm) - +1- 1/4" (6mm) +1- 1/4"(6mm) - 2-7/8 (73mm) - (8mm) 2-1/4" lJ'— (57mm) (49mm) - - DIA. DIA. I Top of Deflector Down From Ceiling to be Either 4" to 6" (100 to 150 mm) or 6 to 12" (150 to 300 mm) Based on Hydraulic Calculations Dimensions F2 & FV Recessed Escutcheon Installation Model F1Res58 HSWX Horizontal Sidewall Sprinkler Hydraulic Design Criteria Minimum Flow and Residual Pressure in Wet Pipe Systemst Maximum Coverage Area(2) ft. x ft. (m x m) Flow gpm (I/mm) Pressure psi (bar) Deflector to Ceiling Distance 18 x 20 (5.5 x 6.1) 30 (114) 26.8(l.85) 4 to 6 inches (100 to 150 mm) 52.4 (3.63) 20 x 20(6.1 x 6.1) 30(114) 26.8(1.85) 16 x 22 (4.9 x 6.7) 33 (125) 32.4 (2.23) 16 x 24(4.9 x 7.3) 38 (144) 42.9 (2.96) 14 x 26 (4.3 x 7.9) 42 (160) 18 x 20(5.5 x 6.1) 35(133) 36.4(2.51) 6 to 12 inches (150 to 300 mm) 62.9 (4.34) 16 x 22 (4.9 x 6.7) 38 (144) 42.9 (2.96) 16 x 24(4.9 x 7.3) 42(160) 52.4 (3.61) 14 x 26 (4.3 x 7.9) 46 (174) Notes: For NFPA 13 installations the flow per sprinkler must be the greater of: (1)the flow listed in the table above or (2) the flow required to achieve a minimum design density of 0.1 gpm/sq ft over the design area of the sprinkler. For coverage area dimensions less than those listed above, use the minimum required flow for the next larger max. coverage area listed. Bulletin 135 Page 13 of 15 October 2019 www.reliablesprinkler.com Model GFR2 Finishes Standard Finishes Special Application Finishes Sprinkler(l) Fl, F2. F/, FP3, CCP, SWC (Conical) Sprinkler (" Sp Fl, F2. FV FP-, CCP, SWC (Conical) Escutcheons Cover Plates (1) Escutcheons Cover Plates (> Bronze Brass -- Bright Brass Bright Brass Bright Brass Chrome Plated Chrome Plated Chrome Plated Dull Chrome Dull Chrome Dull Chrome White White White Paint Black Black Black Paint Polyester 2) Polyester Polyester(') Polyester -- -- -- Custom Color Custom Color Custom Color Paint Polyester Polyester Electroless Nickel -- -- -- PTFE 2) -- -- Notes: Paint or any other coating applied over the factory finish will void all approvals and warranties. cULus Listed Corrosion Resistant. The Model FP escutcheon assembly consists of an unfinished galvanized cup with a finished escutcheon ring. Installation Models Fl Res sprinklers are to be installed as shown in this bulletin. Model Fl, F2, FV, and FP recessed escutcheons are the only recessed escutcheons to be used with Model F1 Res sprinklers. Not all F1 Res sprinklers may be used with all recessed escutcheons offered. Confirm listing of escutch- eon type for use with individual sprinklers. Use of any other recessed escutcheon will void all approvals and warranties. For installing Model Fl Res sprinklers, use only the Model W2 sprinkler Wrench; for installing Models F1 Res Recessed Pendent, Sidewall, Conical Concealed Pendent (CCP), and Sidewall Concealed (SWC and SWC-2) sprinklers use only the Model GFR2 sprinkler wrench. Use of wrenches other than those specified may damage these sprinklers. Model W2 Installation of Fl Res sprinklers in a wall or ceiling will require a hole diameter of 2-1/4" (57 mm) for Fl or F2 recessed escutcheons; or 2-5/8" (67 mm) for FP recessed escutcheons, CCP, SWC, and SWC-2 cover plates. Install Fl Res HSW sprinklers with a ceiling to deflector dis- tance that complies with the hydraulic design criteria tables in this bulletin. The flow arrow on deflector must point away from near wall and 'Top" marking must face the ceiling. A 'leak tight" sprinkler joint can be obtained with the following torque: 1/2" NPT and 1S07-1 R1/2: 8-18 ft-lbs (11 —24 N-m) 3/4" NPT and 1S07-1R3/4: 14-20 ft-lbs (19 — 27 N-m) Do not tighten sprinklers over maximum recommended torque. This may cause leakage or impairment of the sprinklers. Do not install any glass bulb sprinklers where the bulb is cracked or there is a loss of liquid from the bulb. Glass bulb sprinklers have orange bulb protectors to mini- mize bulb damage during shipping, handling and installation. Remove this protection at the time the sprinkler system is placed in service. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when protectors are in place. Remove protectors by undoing the clasp by hand. Do not use tools to remove the protectors. Maintenance Reliable Model F1 Res Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, 13, 13D, and 13R, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuum- ing without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). Properly installed CCP, SWC, and SWC-2 cover plates will have an air gap that is required for proper operation, do not seal the gap or paint the cover plates. Bulletin 135 Page 14 of 15 October 2019 www.reliablesprinkler.com Replace any sprinkler which has been damaged, where cracks are observed in the glass bulb, or when liquid has been lost from the glass bulb. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadver- tent operation or non-operation during a fire event. Listings & Approvals Listed by Underwriters Laboratories Inc. and UL Certified for Canada (cULus) Guarantee For Reliable Automatic Sprinkler Company guarantee, terms, and conditions, visit www.reliablesprinkler.com. Patents For patents applicable to products contained in this technical bulletin, please visit www.r-s.co Ordering Information Specify the following when ordering: Sprinkler Model (See Table A) Temperature Rating Threads (NPT or IS07-1) Finish (See Table N) Escutcheon or Cover Plate Model Finish (See Table N) Sprinkler Wrench Model W2 (Pendent and HSW) GFR2 (Recessed and Concealed) Bulletin 135135 HiIiiI Page 15 of 15 October 2019 www.reliablesprinkIer.com L) C') c,J Q N-0) 0) 0) 0) 0) Bulletin 014 March 2019 Reliable Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR Series Quick Response Glass Bulb Sprinklers Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model Fl FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Standard Spray Upright Standard Spray Pendent Model Fl FR40 Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FR40, Fl FRXLH & Fl FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- kler. Underwriters Laboratories Inc. and Certified for Canada (cULus) in accordance with ANSl/UL199. FM Approvals (FM) Loss Prevention Certification Board (LPCB) VdS Schadenverhutung GmbH (VdS) Underwriters Laboratories Inc. and Underwriters Laboratories of Canada Certified for Health Effects to NSF/ANSI Standard 61 Annex G (ULH) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-40251 (RA1 425), 0786-CPD-40252 (RA1 475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNlV) Quick Response Sprinkler Upright Pendent Conventional Vertical Sidewall Horizontal Sidewall Recessed Pendent/F1/F2 s:/ TJY Recessed Concealed Recessed Horizontal Sidewall Pendent Pendent/FP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 Product Description Reliable Model F1FR series sprinklers , are quick-response automatic sprin- klers with a glass bulb thermal element. '- Model F1FR series sprinklers are Stan- dard Spray sprinklers, with the excep- tion of the Model Fl FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FP tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model F1FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model F1FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model COP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. 2. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model F1FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model F1FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model Fl FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers have a factory-installed Model COP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model COP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model COP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model F1FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model F1FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model GFR2 wrench is used to engage the sprinkler wrench- ing surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup, Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model COP with Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model COP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height Installation Wrench SIN Approvals Listings and Approval Notes US Metric inches mm inches mm Pendent 2.25 57 W2 RA1411 cULus 2 F1FR28 2.8 40 3/8 10 1 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 W2 RA14211 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 W2 RA1413 cULus 2 F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 W2 RA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH Pendent 2.25 57 W2 RA1413 cULus 2 (F1FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 W2 RA1423 cULus 1,2 Pendent 2.25 57 W2 RA1414 cULus FM , , LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPcB, VdS, EC 1,2,3,4 F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 GFR2 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 W2 RA1425 cULus, FM, LPCB, VdS, EC 1,2,3,4 Conventional (Pendent or Upright) 2.25 57 W2 RA1475 LPCB, VdS, EC 4 Pendent 2.25 57 W2 RA1415 cULus, ULH 1 F1FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 GFR2 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 W2 RA1435 cULus, FM 1,2,3,7 F1FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 W2 RA1485 cULus, FM, LPCB 1,2,3,9 I cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. ) Model F1 FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. 7) cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4 inches to 12 inches (102mm to 305mm). FM Approval of the F1FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (8) cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. 9) The Fl FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. LPCB approval of the Fl FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Model Ordinary Temp. Classification Deflector/ 100°F (38°C) Max. Ambient Temp. Orientation 135°F (57°C) 155°F (68°C) Temp. Rating Temp. Rating Orange Bulb Red Bulb Intermediate Temp. Classification 150°F (65°C) Max. Ambient Temp. High Temp. Classification 225°F (1 07°C) Max. Ambient Temp. 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I Upright cULus F1FR4O Pendent VdS Recessed Pendent VdS I Pendent cULus F1FR42 Recessed Pendent cULus I Upright cULus F1FR42LL Pendent cULus ULH Recessed Pendent cULus, ULH Pendent cULus F1FRXLH Recessed Pendent cULus I Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC FIFR56 Concealed Pendent* cULus I cULus,VdS,EC I cULus Upright cULus, FM, LPCB, VdS, EC 'Conventional 1 LPCB VdS EC [(—Pendent or Upright)" Pendent cULus, ULH FIFR56LL Recessed Pendent cULus, ULH Concealed Pendent* cULus, ULH Horizontal Sidewall cULus, FM FIFR56 Recessed Horizontal cULus FM Sidewall F1FR56 Vertical Sidewall (Pen- cULus, FM, LPCB dent _or_Upright) * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model COP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Deflector! Model (Fig. 1 & 3) (Fig. I & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 FIFR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42)(LH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS, EC F1FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 FIFR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS -\ Fl ESCUTCHEONj_ 3/4 '[19mm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12.7mm] ADJUSTMENT 2 1/4" HOLE 0/4. [57.2mm] 1 75/16" 0/A (49.2mm] L—_+---- r 1 \ I I (1 I 1" X 1/2" REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4 119mm] AT MINIMUM RECESS = 3/8'19.5mm] Fl ESCUTCHEON J AT MAXIMUM RECESS = 7/8'122.2mm] 1 [3.2mm] I / AT MINIMUM RECESS = 1-5/8 141.3mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'128.6mm] AT MINIMUM RECESS = 1-5/8'14 1.3mm] 2 27/32" 0/A. [72.2mm] Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon 1 X 1/2 REDUCER 2 5/8" 0/A. [66.7mm] " " HOLE IN CEILING \ / 2 5/16" 0/A. [58.7mm] -m CUP CEILING FACE OF FITTING AT & ii MAXIMUM RECESS = 1-1/2'T38mm] I TO FACE OF CEILING I DIMENSION AT MINIMUM RECESS = 1 '125.4mm] AT MINIMUM RECESS = 1 125.4mm] Y2 '112.7mm] J AT MAXIMUM RECESS 9/16"[14.3mm] = ADJUSTMENT 31/4"DIA. [82.6mm] I Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. F! ESCUTCHEON LL r I IA tfljfl III nccrc'e - 4 7 / "r n..... -, jmm] /1! IVIflAIIVIL1IW CIAC),) I ,.'/ 0 1 .J't. 1IIftIJ AT MINIMUM RECESS = 2-1/16 "[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8 "[41.3mm] AT MINIMUM RECESS = 2- 1/16"[52.4mm] FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1 "[25.4mm] AT MINIMUM RECESS 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE DIA. [5 7.2mm] 1" X 1/2" REDUCER A 1 15/16" DIA.,Li [49.2mm] 2 27/32" DIA. [72.2mm] I (1) 4"-12" [10 1.6mm-304.8mm] CEILING TO DEFLECTOR TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON 3/4"[1gmm] ADJUSTMENT F2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT 0010036 RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW + - 2 5/8" 0/A. 2 5/16" 0/A - ________________ HOLE IN CEILING CUP -. t1 1-i CEILING -' 1/2" MAX. I COVER ADJUSTMENT COVER PLATE ASSEMBLY 5/76" 0/A SPRINKLER 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 7 15/16" CONCEALED, 1/2" ADJUSTMENT 01 7FG01A Fig.4 Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model CCP cover plate N. I" x 1/2" REDUCING TEE OR ELBOW T I - 25/8 0/A. 2 5/16" 0/A - ______ - HOLE IN CEILING CUP ovu -J 1 1/2k" MAX. FACE OF FITTING TO FA DIMENSION CE OF CEILING CEILING 3/4 COVER ADJUSTMENT COVER PLATE / ASSEMBLY - 3 5/16 0/A. - SPRINKLER CONCEALED, 5/1 6" ADJUSTMENT 07FCO2A Fig. 5- Model Fl FR56/171 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model COP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) Standard Finishes Sprinkler Escutcheon Cover platet't Bronze Brass Chrome Chrome Plated Chrome Plated White Polyester Coated OPP White Painted Special Application Finishes Sprinkler Escutcheon Cover plate1t Electroless Nickel PTFE(7) Electroless Nickel PTFE Bright Brass Bright Brass(3) Bright Brass Black Plating Black Plated Black Plated Black Paint Black Paint(2116) Black Paint Off White Off White (2)(15) Off White I Satin Chrome Chrome Dull Chrome Dull I Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. (2) cULus Listed only. ) 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSw), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant Material Data Frame: DZR Brass, QM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [F1FR28][F1FR40][F1FR42] [Fl FR42LL][F1 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent] [Upright] [Conventional] [Horizontal Sidewall] [Recessed Horizontal Sid ewall][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1121 Sprinkler Temperature Rating: [135°F (570O)][155°F (68°C)][175°F (79°C)][200°F (93°C)][286°F (14100)] Sprinkler Finish 6, Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile COP 1/2-inch (12.7mm) adjustment][low profile COP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][ 1 650F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model El FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled 0 (800) 431-1588 Sales Offices E-Paper Rell (800) 848-6051 Sales Fax Revision lines indicate updated or new data. (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address EG. Printed in U.S.A. 03/19 P/N 9999970300