Loading...
HomeMy WebLinkAbout4422 ADAMS ST; ; FPR2018-0104; PermitPERUtT REPORT (C i t y of Carlsbad I AffG pDhm Print Date: 08/30/2022 Permit No: FPR2018-0104 Job Address: 4422 ADAMS ST, CARLSBAD, CA 92008 Status: Closed - Finaled Permit Type: FIRE-Construction Residential Work Class: Single Family Fire Sprinkl Parcel #: Track #: Applied: 04/23/2018 Valuation: $709,747.24 Lot #: Issued: 06/25/2018 Occupancy Group: Project #: DEV2016-0058 Finaled Close Out: 12/05/2019 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check#: INSPECTOR: Fieri, Dominic Plan Check #: Salcedo, Felix Project Title: KLOVANISH RESIDENCE Description: KLOVANISH RESIDENCE NEW SFD -SPRINKLER (49 HEADS) FPContractor: MCMAHON FIRE PROTECTION INC 16458 AVEN IDA VENUSTO SAN DIEGO, CA 92128-6240 (619) 992-3034 FEE AMOUNT FIRE NFPA 13D Single Family System (Insp/Bldg) $121.00 FIRE NFPA 13D Single Family System (Plan Review) $239.00 Total Fees: $360.00 Total Payments To Date: $360.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov request 1 message Land Development Engineering <LandDevcarlsbadca.gov> Tue, Mar 27, 2018 at 11:19 AM To: todd mcmahon <mcmahonfiregmail.com> The APN you gave me was for the Kiovanish Residence and their Address is 4422 Adams not the 4385 Adams listed below. I calculated the following range for the street level Static Pressure. 63.65 psi - 61.05 psi The grading plans indicate a 1" service lateral and a 1" meter. Hope this helps and have a wonderful day. Kindest Regards VaiRay (City of Carlsbad From: todd mcmahon [mailto:mcmahonfireo)gmaiI.com] Sent: Tuesday, March 27, 2018 10:35 AM To: Land Development Engineering <LandDevCarlsbadCA.gov> Subject: Re: request Hi, the APN for 4385 Adams St is 206-180-41, thank you, Todd On Mon, Mar 26, 2018,3:59 PM Land Development Engineering <LandDevcarlsbadca.gov> wrote: Please send the APN for this location the address does not exist. Kindest Regards ValRay From: todd mcmahon [mailto:mcmahonfiregmail.com] ' •1 Sent: Monday, March 26, 2018 3:58 PM To: Land Development Engineering <LandDevCarlsbadCA.gov> Subject: request Hi, do you have the static water pressure for 4385 Adams St.? Also do you require a new 1 service to the 1 meter for fire service? Thanks, Todd 1§ @8 OO Dashboard Hjdraullm Hydraulics Summary Sheet Project Information Calculation Date: 4/8/2018 3:11 PM KLOVANISH RES system ID drawing ref building 2 STORY 4385 ADAMS ST construction VB CARLSBAD CA. 92008 occupancy R3 contract # 2018 authority CITY OF CARLSBAD CnnIrttnr Tnfnrmdinn McMahon Fire Protection Inc. 16458 Avenida Venusto unit A San Diego Ca. 92128 calculated by Todd L. McMahon telephone 619-992-3034 fax email mcmahonfiregmaiI.com - Sprinklers in Remote No. Mfgr Mod SIN# Size K L 2 1 VIKING I FREEDOM I VK488 1 7/16 3.00 Hydraulics Criteria density .05 GPMGPM/ft'system type WET design std NFPA 13D remote area GUEST hazard LIGHT spr coverage YWUM tt' sprs flowing 2 figure curve CIna, Tact static pressure 54.90 psi residual pressure 20.00 psi quantity flowing 1,100.0 GPM date & time of flow test see attached location of flow test 100 95 90 85 80 75 70 65 60 -&55 - 50 :2 45 40 a 35 - 30 25 20 15 10 5 0 54.88 psi available at Sprinkler Demand of 46.06 psi with System Flow of 21.1 GPM —I Marain: +16.1% I- -----4------- it- -- -----H------_ LL1117____ 2l.1GPM 85 05 10 15 20 25 30 Water Flow (GPM) 0 Copyright 2016 Sigma Development Group, Inc. Page 1 of 4 4 8OO Dashboard Hydiauiks Supply Analysis KLO VANISH RES Sprinkler Flow: 16.IGPM Additional Flows: 5.0 GPM Hose Flow at Zero: None Total System Flow: 21.1GPM Maximum velocity in pipe 0-1 is 8.7 ft/sec Nodes Analysis Minimum Node Actual Node Elev Device KFactor Flow Pressure Discharge Notes ft GPM psi GPM 15 31.00 Sprinkler 3.00 8.00 7.32 8.12 16 31.00 Sprinkler 3.00 8.00 7.11 8.00 5 18.00 Hose Flow 19.16 5.0 © Copyright 2016 Sigma Development Group, Inc. Page 2 of 4 4!800 Dashboard Hydraulics Pipe Information KLOVANISH RES From EleVi Pipe ID Flows Length if ' I C Value I Total (Pt) psi I ft Added GPM inside Diameter Fittings I Notes Fitting ft I Elev (Pe) psi I To Eiev2 Type in Friction Loss Total Total ft1 psi/ft Frict (Pf) psi 0 0.00 1" Type K 0.9950 E,T,GV Len 24.01 Ftg 9.3 C=150 Pt 1) 41.952 Pe 0.000 Pf 4.107 1 0.00 UN 21.1 0.12318 Total 33.3 Total Pressure at Node 0) 46.058 psi 1 0.00 1" Type L 1.0300 RFM Len 1.01 Ftg 0.0 150 Pt 38.402 Pe 0.000 Pf 0.104 1 Hersey Residential Fire Meter Model RFM 30: Loss = 345 2 0.00 UN 21.1 0.10409 Total 1.0 Total Pressure at Node 1) 41.952 psi 2 0.00 1" Type L 1.0300 Len 2.0T Ftg 0.0 C = 150 Pt 3) 38.193 Pe 0.000 Pf 0.208 3 0.00 UN 21.1 Totalt04 Total Pressure at Node 2) 38.402 psi 3 0.00 1 Type L 1.0300 RPZ,4E JLen 2.0[ Ftg 11.1 C=150 Pt 4) 27.140 Pe 0.000 Pf 1.358 Zuml Reduced Pressure Zone Assembly Model 975XL2: Loss = 9.69 4 0.00 UN 21.1 0.10409 Total 13.1 Total Pressure at Node 3)38.193 psi 4 0.00 2" CPVC 19.163 2.0030 E Pe 7.799 5 Ftg 6.5 18.00 UN 21.1 0.00408 Pf 0.177 Total 43.5 Total Pressure at Node 4) 27.140 psi 5 18.00 Ill Type L 1.0300 CV Len 9.01 Ftg 6.9 C = 150 Pt 6) 14.259 Pe 3.900 Pf 1.004 6 27.00 UN 16.1 0.06314 Total 15.9 Total Pressure at Node 5)19.163 psi 6 27.00 1" CPVC Len 4.0 C = 150Pt 7) 12.344 1.1010 Ftg 0.0 Pe 1.733 7 31.00 UN 16.1 0.04564 Pf 0.183 Total 4.0 Total Pressure at Node 6)14.259 psi 7 31.00 1" CPVC Len 20.0 T c = 150 Pt 8) 11.256 1.1010 E,3TR Ftg 3.8 Pe 0.000 8 31.00 UN 16.1 0.04564 Pf 1.087 Total 23.8 Total Pressure at Node 7)12.344 psi 11 41.00 Ill CPVC 1.1010 Len 10.0 915 e -4.333 Pt 14) 8.481 P Pf 0.631 14 31.00 UN 16.1 0.04564 Total 13.8 © Copyright 2016 Sigma Development Group, Inc. Page 3 of 4 fOO Dashboard ffi'drau!ks Pipe Information KLOVANISH RES From EleVi Pipe ID Flows Length ft -I C Value [Total (Pt) psi ft Added GPM Inside Diameter Fittings Notes Fitting ft I Elev (Pe) psi I To EIev2 Type in I Friction Loss Total Total ft psi/ft [Frict (Pf) psi Total Pressure at Node 11) 4.779 psi 14 31.00 1" CPVC 1.1010 3E,TR Len 14.01 Ftg 11.5 C=150 Pt 15) 7.319 Pe 0.000 Pf 1.162 15 31.00 UN 16.1 0.04564 Total 25.5 Total Pressure at Node 14) 8.481 psi 15 31.00 ill CPVC 1.1010 2E Len 9.01 Ftg 7.6 C=150 Pt 16) 7.111 Pe 0.000 Pf 0.208 16 31.00 UN 8.0 Total 16.6 Total Pressure at Node 15) 7.319 psi 8 31.00 1° CPVC 1.1010 T,5TR Len 64.01C Ftg 9.6 -150 Pt 9) 10.062 Pe 0.000 Pf 1.195 9 31.00 CM 9.2 0.01624 Totai7i1 Total Pressure at Node 8)11.256 psi 9 31.00 1" CPVC 1.1010 E Len io.oJ Ftg 3.8 C=150 Pt 10) 5.504 Pe 4.333 Pf 0.225 10 41.00 CM 9.2 0.01624 Total 13.8 Total Pressure at Node 9)10.062 psi 10 41.00 ill CPVC 1.1010 2E,3TR Len 37.0T Ftg 7.6 C=150 Pt 11) 4.779 Pe 0.000 Pf 0.725 11 41.00 CM 9.2 0.01624 Total 44.6 Total Pressure at Node 10) 5.504 psi 8 31.00 1" CPVC 1.1010 2E,8TR ken 72.0 Ftg 7,6 C = 150 Pt 13) 10.501 Pe 0.000 Pf 0.756 13 31.00 CM 6.9 0.00949 Total 79.6 Total Pressure at Node 8)11.256 psi 13 31.00 11, CPVC 1.1010 E ILen 10.01 I Ftg 3.8 C = 150 IPt 12) 6.036 Pe 4.333 Pf 0.131 12 41.00 CM 6.9 - 0.00949 Total 13.8 Total Pressure at Node 13) 10.501 psi 12 41.00 ill CPVC 1.1010 3E,10TRjFtg Ten 121.0[ 11.5-_--_------]pe C=150 Pt 11) 4.779 Pf 1.257 0.000 11 41.00 CM 6.9 0.00949 ri-i-"1 Total Pressure at Node 12) 6.036 psi © Copyright 2016 Sigma Development Group, Inc. Page 4 of 4 okok Page 1 o 6 SrjII(JF4f1GJ - FREEDOM® RESIDENTIAL II[1U.7'if CONCEALED PENDENT SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com DESCRIPTION 'liking Freedom* Residential Concealed Pendent Sprinkler VK488 is a small high- sensitivity solder link and lever residential sprinkler designed for installation on con- cealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-Factor of 3.0 (43.2 metric*), allows the sprinkler's efficient use of available water supplies for the hydraulically designed fire-protection system. The operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low- profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The "push-on", "thread-off' design of the concealed cover plate assembly al- lows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2 (12.7 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing tempo- rary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS • - .. " * -. - - - UL Listed (C-UL-US-EU): Category VKKW Eu Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2013. Minimum Operating Pressure: Refer to the Approval Chart. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 1/2' (15 mm) NPT Nominal K-Factor: 3.0 U.S. (43.2 metric*) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 or QM Brass Deflector: Phosphor Bronze UNS-051000 Viking Technical Data may be found on Deflector Pins: Stainless Steel UNS-530200 The Viking Corporation's Web site at Button: Brass UNS-C36000 http:llwww.vikinggroupinc.com. Seat Assembly: Brass UNSC31600 The Web site may include a more recent Compression Screw: Brass UNSC36000 edition of this Technical Data Page. Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint Levers: Stainless Steel UNS-531600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Cover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc Plating Shipping Cap: Polyethylene Cover Plate Materials: Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom5 Residential Concealed Pendent Sprinkler VK488 and Cover Plate Assembly must be ordered separately: Sprinkler: Base Part No. 18325A. Temperature suffix: 165 "F (74 °C) = C and 205 °F (96 °C) = E Form No. F_073012 16.05.19 Rev 16.1 Replaces Form No. F_073012 Rev 14.1 (Added 205 "F196 °C rated version) Page 2 of 6 II[I1iUIJIf - FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Cover Plate Assembly: Base Part No. 13504 (2-3/4" diameter), Base Part No. 13642 (3-5/16" diameter), No. 15394 (square cover plate, 3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/W, Painted Ivory = M-/l, Painted Black = M-/B Temperature Suffix: 135°F (57 °C) =A, 165°F (74 "C) = C For example, cover 13504 with a Polished Chrome finish and a 135 "F (57 °C) temperature rating = 13504FA. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches**: Heavy Duty Part No. 13623W/B (available since 2006), or Head Cabinet Wrench Part No. 13619* (available since 2006) Optional Concealed Cover Plate Installer Tool Part No. 14412 (available since 2007) Optional Large Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a W ratchet (not available from Viking). —Also optional for removal of the protective cap. Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches, releasing the deflector. Continued heating of the exposed sprinkler causes the fusible element to disengage releasing the sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY Viking Sprinkler Model VK488 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Sprinkler Nominal Maximum Temperature Rating Cover Plate Large Cover Square Cover Temperature Temperature Ambient Ceiling of the Cover Base Part Plate Base Plate Base Classification Rating' Temperature' Assembly (Required) Number' Part Number3 Part Number' Ordinary 165 "F (74 "C) 100 "F (38 °C) 135 "F (57 "C) 13504 13642 15394 Intermediate 205 "F (96 "C) 150 °F (65°C) 135 °F (57 "C) or 13504 13642 15394 1 1 1 Cover Plate Finishes: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black Footnotes The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13, NFPA 13R, and NFPA 130. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Part number shown is the base part number. For complete part number, refer to current 'liking price list schedule. Form No. F073012 16.05.19 Rev 16.1 Page 3 of 6 \J IIIIs1G ® - FREEDOM® RESIDENTIAL II[iUi1IfA CONCEALED PENDENT SPRINKLER VK488 (K3M) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart I Viking VK488, 30 K-Factor Concealed Pendent Sprinkler (Ordinary Temperature) For systems designed to NFPA 13D or NFPA 13R For systems designed to NFPA 13 refer to the design criteria. For Ceiling types refer to NFPA 13,1311 or 13D 2013 Editions Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Part Number" SIN Working Pressure Inches mm U.S. metric2 18325AC VK488 1/2 15 3.0 43.2 175 psi (12 bar) Max. Coverage Ordinary Temp Rating (165 *F/74 *C) Listings and Approvals3 Minimum Area6 Deflector to _________ _________ _________ Spacing Flow6 Pressure6 Ft X Ft. Ceiling Installation Type Ft. (m X m) GPM PSI Cn us NYC NSF (m) (Umin) (bar) EU 12X12 8 7.1 (3.7 X 3.7) (30.3) (0.49) Concealed with See ee See 8 14 X 14 11 13 4 (4.3 X 4.3) (41.6) (0.92) Refer to Figure 2 Cover Plate Footnote 8 Footnote 5 Footnote 8 (2.4) Assembly and 10 and 10 16X16 13 18.8 (4.9 X 4.9) (49.2) (1.30) Footnotes 1 Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. Meets New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the 'Flow' and "Pressure" for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure" used. UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MR48034). "Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 11. Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Cover Temperature Rating is 135 "F (57 "C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). Form No. F073012 16.05.19 Rev 16.1 Page 4 of 6 FREEDOM® RESIDENTIAL II[IflUI7f CONCEALED PENDENT 'ItttiJ IIIIs1G ® - SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com Approval Chart 2 Viking VK488, 30 K-Factor Concealed Pendent Sprinkler (Intermediate Temperature) For systems designed to NFPA 130 or NFPA 13R. For systems designed to NFPA 13, refer to the design criteria. For Ceiling types refer to NFPA 13, 13R or 130 2013 Editions Sprinkler Base NPT Thread Size Nominal K-Factor Maximum Water Part Number' SIN Working Pressure Inches mm U.S. metric2 18325AE VK488 1/2 15 3.0 43.2 175 psi (12 bar) Intermediate Temp Max. Coverage Rating (205 °F196 °C) Listings and Approvals3 Minimum Area6 Deflector to _________ _________ _________ Spacing Flow6 Pressure6 Ft X Ft Ceiling Installati on Type Ft. (m X m) GPM PSI 4 c®us NYC NSF7 (m) (Umin) (bar) EU 12X12 8 7.1 (3.7 X 3.7) (30.3) (0.49) Concealed with See See See 8 14X14 11 13.4 (4.3 X 4.3) (41.6) (0.92) Refer to Figure 2 Cover Plate Footnote 8 Footnote 5 Footnote 8 (2.4) Assembly and 10 and 10 16X16 13 18.8 (4.9 X 4.9) (49.2) (1.30) Footnotes I Part number shown is the base part number. For complete part number, refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. Listed by Underwriter's Laboratories, Inc. for use in the U.S., Canada, and European Union. New York City requirements, effective July 1, 2008. 6 For areas of coverage smaller than shown, use the "Flow" and "Pressure" for the next larger area listed. Flows and pressures listed are per sprin- kler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum "Flow" and "Pressure" used. UL Classified to: NSF/ANSI Standard 61, Drinking Water System Components (MH48034). 8Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 9. Other paint colors are available on request with the same C-UL-US-EU listings as the standard finish colors. 10 Cover Temperature Ratings are 135 OF (57 "C) and 165 OF (74 "C). Cover Part No. 135041, 136421 (large diameter), or 153941 (square cover plate). Form No. F073012 16.05.19 Rev 16.1 Sprinkler and Adapter Assembly (Protective Cap is removed for installation--use Wrench 13619w0 Step 1: Carefully sl wrench sideways a the deflector anc 2-1/4" (57.2 mm) diameter opening is required in the ceiling. 127 Sprinkler Wrench (Part No. 1362 3W/B)Kw is shown) Page 5 of 6 FREEDOM® RESIDENTIAL I "1 Ki F41G ® CONCEALED PENDENT SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EUI: When using Viking Residential Concealed Pendent Sprinkler VK488 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover- age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, Calculated based on a minimum discharge of 0.1 gpmlsq. ft. over the design area" in accordance with sections 8.5.2.1 or 8.6.2.1.2 of NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). jq~Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RESI-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. *SA 1/2" ratchet is required (not available from Viking). Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with sprinkler wrench flats. Figure 1: Sprinkler Installation and Correct Use of Wrenches Form No. F073012 16.05.19 Rev 16.1 Page 6 of 6 CONCEALED PENDENT s,j II(II1G FREEDOM® RESIDENTIAL SPRINKLER VK488 (K3.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1/2' (15 mm) NPT (54 mm) T-- 2-9/16' (65 mm) Maximum 2-1/16' (52 mm) Minimum 2-3/4' (70 mm) or Note: Upon sprinkler activation, the deflector descends 3-5/16' (84.1 mm) to approximately 13/16' (20,6 mm) below the sprinkler body, Figure 2: Sprinkler Dimensions and Cover Installation DO NOT PAINT 3-5/16' (84.1 Figure 4: Square Cover Assembly 15394 Identification of Custom Paint Color" All custom color painted cover plates will have an identifying label affixed to the inside of the cover" that indicates custom color and will have a representative sample (a paint clot) of the paint on the label. Figure 3: Identification of Custom Paint Color for Concealed Covers Form No. F_073012 16.05.19 Rev 16.1 Replaces Form No. F_073012 Rev 14.1 (Added 205 °F/96 °C rated version) VIC Fire Protection Products Worldwide www.tyco-fire.com Contacts Series TY.FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 inch (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 inch (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 NOTICE _ The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313 .....Upright 5.61K, 1/2NPT TY323 .....Pendent 5.61K, 1/2 NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries, Inc. (UL). Discharge Coefficient K=5.6 GPM/psi½ (80,6 LPM/bar'1') Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb...............................Glass Compression Screw .................Bronze Deflector ..........................Bronze JULY 2017 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (1Y323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 TFPI72 Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2' 7/16' (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* 5 7/16' __ 1(11,1 mm) MAKE-IN _____ (50,6 mm) : I NOMINAL 2 t - I - 2" \fl / 11/ I 1-3/8' (50,8 mm) (34,9 mm) WRENCH ________ FLATS 1/2" NPT** DEFLECTOR * 2-7/8" (73,0 mm) DlA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS £6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-f actor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F (57°C) and 3/32 inch (2,4 mm) for the 286°F (141°C) tem- perature ratings. A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 It-lbs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. / WRENCH RECESS / (USE ONLY FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH INTO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH TFPI72 Page 3 of 4 Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 2-7/8 DIA. (73,0 mm) 2-1/4 DIA. FACE OF - (57,2 mm) SPRINKLER 5/8' (15,9 mm) FITTING FLUSH 3/8±5/16" (9,5±7,9 mm) / MOUNTING / 1/8" SURFACE - (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 3/4' (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8" DIA. - (73,0 mm) FACE OF SPRINKLER 2-1/4' DIA. FITTING - (57,2 mm) 5/16±1/4" 1/2(12,7mm) (7,9±6,4 mm) \ 6(3,2 FLUSH . MOUNL>/ SURFACE m) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TYFRB PLATE 7/8" (22,2 mm) FIGURES SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON P/N*77_X(X SIN 370 5.6K UPRIGHT (1/2 NPT) TY313 371 5.6K PENDENT (112 NPT) TY323 * Use suffix *1 for ISO 7-1 connection; for example, 77-370-4-175-I TFPI72 Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS P HROME FC PLATED LA POLYESTERC 135°F (57°C) Orange UPRIGHT 155°F (68°C) Red 175°F (79°C) Yellow and 1, 2, 3, 4, 5, 6 5.6 1/2" NPT PENDENT (1Y323) ________________ 200°F (93°C) Green 286°F (141°C) Blue 135°F (57°C) Orange RECESSED PENDENT (TY313) Figures 4a and 5b 1 2 3 4 155-F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E- VdS Approved (For details, contact TYCO Fire Protective Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a106) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15 (1/2" NPT) 5/8" Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2" NPT) 1/2" Total Adjustment Recessed Escutcheon, as applicable. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS -xxx —11 SPRINKLER TEMPERATURE FINISH I I RATINGS 1 I NATURAL BRASS 135 135-F (57-C) 155 155°F(68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) I PURE WHITE (RAL9010)°° POLYESTER SIGNAL WHITE (RAL9003) POLYESTER JET BLACK (RAL9005) POLYESTER 9 I CHROME PLATED Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 19446J Telephone +1-215-362-0700 Copyright © 2017 Tyco Fire Products, LP. All rights reserved. TEFLON is a registered trademark of DuPont tqco Fire Protection Products Residential Fire Meter Sizes 3/4, 1", 1-1/2" and 2" Features APPLICATIONS: The Hersey Residential Fire Meter (RFM) is specifically designed for use in residential fire protection systems or combination systems that supply domestic plumbing needs and residential sprinkler fire protection service when installed as specified in NFPA 13D orNFPA 1313; (Standards for the installation of sprinkler systems in one and two family dwellings, manufactured homes and residential occupancies up to and including four stories in height). The RFM utilizes Herseys unique vertical turbine measuring element to measure flow rates comparable to traditional positive displacement meters, yet provides a measuring element that allows suspended particulate matter to pass through the element unobstructed When emergency flow requirements for water are demanded. No other meter provides more flexibility and dependability for measuring water accurately in residential fire suppression and domestic use applications. CONFORMANCE TO STANDARDS: Each Hersey Residential Fire Service Meter is tested to assure compliance with ANSI/AWWA Standard C701, Class 1. Each male and female threaded RFM has UL Approval. EnviroBrass Il® options conform to the NSF 61 Standard. CONSTRUCTION: Hersey Residential Fire Water Meters consist of three basic parts: maincase, rotor assembly, and a permanently sealed register. Maincases and bottom plates are made of bronze for long service life. Rotor assemblies are thermoplastic, which is dimensionally stable and will not corrode. Retro Thrust® rotor design extends the life of the meter by dividing wear between two points: during low flow the tungsten carbide thrust bearing floats against a sapphire bearing surface; during high flow the stainless steel shaft gently contacts a second sapphire bearing and during medium flow, the rotorfloats between the thrust bearings without contact. The measuring chamber is protected by an internal strainer with four times the effective straining area of the inlet pipe diameter. No external strainer is required. Fire service connections are easily recognized by the bright red register collar and lid on all visual read meters. Electronic meters are distinguished by the red collar and lense terminal cover on top of the Translator® register. Optional test ports are available on all 1-1/2 and 2" meters. REGISTER: The permanently sealed register has a unique L seal and heat treated glass to eliminate dirt, moisture infiltration and lens fogging. The totalizing register has a straight-reading odometer type display, a 36O test circle with center sweep hand and a low flow (leak) detector. All Hersey Meter models have electronic meter reading systems available for increased reading efficiency (see Meter Reading Systems). OPERATION: Water flows through the integral strainer and into the vertical turbine assembly. There, the direction of the water flow is directed by the hub into the rotor at the precise angle necessary for accurate measurement over the full range of flow rates. No straight pipe requirements apply before or after the meter. The turbine turns freely and rotates in direct proportion to the volume of water passing through the meter. The Hersey turbine operates more quietly than conventional disc or piston meters. MAINTENANCE: All Hersey Residential Fire Meters are designed and manufactured to provide long service life. The register on all sizes can be replaced without removing the meter from the line. Modular design and economical internal parts allow for inexpensive, speedy rebuilds. CONNECTIONS: Available with external (N.P.S.M.) straight pipe threads (ANSI 131.20.1) on 3/4" and 1' sizes; internal (NPT) pipe threads (ANSI 131.20.1) on 1-1/2' and 2° sizes. AFMIU11811ef SYSTEMSIJ - K2,019.-60+ 211 RFM 160 L1sia MODEL Residential Fire Meter (RFM) SIZES 3/4", 1", 1-1/2' and 2" STANDARDS Manufactured and tested to meet or exceed all applicable parts of ANSI/AWWA C701, Class 1 Standard All Male and Female Threaded RFMS have UL Fire Service Approval SERVICE Cold water measurement with flow in only one direction OPERATING FLOW RANGE See Charts ACCURACY See Charts MAXIMUM WORKING PRESSURE 175 PSI Meets Hydrostatic Pressure Testing to 875 PSI. TEMPERATURE RANGE 33°F TO 130°F MEASURING ELEMENT Rotor STRAINER 4 times the inlet pipe diameter of straining surface area with .080 perforations. REGISTER TYPE Straight reading, permanently sealed, magnetic drive with low flow indicator. Remote reading units optional. METER CONNECTIONS 3/4" and 1" external (NPSM) straight pipe threads, 1-1/2" size and 2" size available with internal thread (NPT) ends same nominal size as size of meter MATERIALS Maincase - bronze UNSC84400; Rotor assembly - thermoplastic; Strainer - stainless steel; Casing bolts - stainless steel ANSI B18. OPTIONS Meter case - EnviroBrassll® UN5C89520, Translator registers and AMR Systems AuellefSYSTEMS [M,i 1 el IIR1F 11 Residential Fire Meter Sizes 3/4", ill 1-1/2" and 2" N-'0=Lmm II tc U Meter Size Initial Dial * Capacity 'Initial Dial * Capacity 3/4' 10 Gallons 10 Million I Cubic Foot 1 Million 1' 10 Gallons 10 Million 1 Cubic Feet 1 Million 1-1/2° 100 Gallons 100 Million 10 Cubic Feet 10 Million 2" 100 Gallons 100 Million 10 Cubic Feet 10 Million Meter Size - I Typical Low Flow (95% Minimum) I Typical Operating Range (100% ± 2%) I Maximum Continuous Operation Maximum Intermittent Flow 3/4' 1/2 GPM 1 t 30 GPM 25 GPM 35 GPM 1° 3/4 GPM 1-1/2 to 50 GPM 35 GPM 55 GPM 1-1/2 1-1/2 GPM 2 to 100 GPM 70 GPM 110 GPM L2L__j 2GPM 3toi60GPM 115 GPM 175 GPM 1...... J *Registration equal to one full revolution of the sweep hand. A___ 3/4" and 1" COMPACT RFM 1-1/2" and 2" COMPACT RFM with Internal NPT ends Meter Size 3/4" 1" 1-1/2 2" Ends Threaded (screwed) I Juii Lø Dimensions A 7-1/2° 9" 9" 10-1/2' B 5" 5-1/2" 5-3/4" 6-1/4" C 1-13/16" 2-3/8" 2-3/8" 3" Max.width 3-3/4" 4-1/4" 4-3/8" 5-3/8" Net weight 1 5* 7* 9* 14* * Weights are in pounds and are approximate. 2 0 5 10 20 30 40 50 RATE OF FLOW - U.S. GPM Head loss - 1-1/2" and 2" ii. :, : uiuuiuuiu iiuinnii• 0 5 10 20 30 40 50 RATE OF FLOW - U.S. GPM Accuracy— 1-1/2" and 2" II w W@0U Lk II Residential Fire Meter Sizes 3/4M, 1", 1-1/2" and 2" Aim Ii[MUellef SYSTEMS - I Head loss - 3/411 and 1" Accuracy - 3/4" and 1" I I 18 A IIIuuuuuI_______ 16 UIflllllil ' j w 14 llhIIHHI Ir ir UD 12 I10 cc lIIHhIIII lIIilhIII r 0 cc a- - 18 (I) a 16 14 12 (I) w 10 cc (- 8 U- 06 U) (I) 4 0 2 IIIIIIIIII_-______ ' 94 91. uuumui ir 0 20 40 60 80 100 120 140 160 0 20 40 60 80 100 120 140 160 RATE OF FLOW - U.S. GPM RATE OF FLOW - U.S. GPM *Performance curves are typical only and not a guarantee of performance. V- -- - -- - -- - =A-pro A, 1 2 6 3 5 8 9 10 rfirlmfi-, iiIInr cZVcZTrAAl X Mode's RFM-30, RFM 50, RFM 100 and RFM 160 0- 7 13 12a .1 14 14 11 15 ill LJxJU LLLJ Models RFM-30, REM 50, RFM 100 and REM 160 111 Mueller SYSTEMS Ref. No. Description Model RFM-30 Model RFM-50 Model RFM-100 Model RFM-160 1 Lid (Plastic) Red 50377FS 50377F5 50377FS 50377FS 2 Red Clamp Band for Visual Register Red Clamp Band for Translator Register 50379FS B8602FS 50379FS B8602FS 50379F5 B8602FS 50379FS B8602FS 3 Lid Seal Screw 19945 19945 19945 19945 4 Lid Nut 19999 19999 19999 19999 5 Sealed Registers (Specify unit of measurement) See pages 7.7-7.8 6 RFM 30 Top Case (7-1/2 length): 3/4" M.I.P. Ends 50466(A) - - - 6 RFM 50 Top Case (9" length): M.I.P. Ends - 50566F5 (B) - - 6 RFM 100 Top Case (9 length): 1-1/2 F.I.P. Ends - - 50776F5 (C) - 6 RFM 160 top Case (10-1/2 length): F.I.P. Ends - - - 50866FS (0) 7 Rotor 50471 50571 50771 50871 8 Inlet Hub 50461 50561 50761 50867 9 Lower Bushing 50374 (2) 50574 (2) 50574 (2) - 10 Interior Screw 98394 (4) 98394 (4) 98394 (4) 98394 (4) 11 Strainer (Metal Ring) 50480 50580 50180 50880 12a Rubber Gasket - B7647 50786 C5488 12b Liner 50365 B7646 50166 C5491 13 Inlet Plug Assembly 50493 50493 50493 53105 14 Bottom (Bronze) only C6592 C6593 C6594 03594 15 Case Washer A51792 (4) A57792 (4) 98378 (4) 98318 (4) 16 Case Bolt 90010 (4) 90010 (4) 90073 (4) 90073 (4) Bushing Spacer - - - 53114 Bushing - - - 54915 (2) Sapphire Thrust Bearing (Case) 98371 98371 98311 98371 Complete Interior 50477FS 50577FS 50771F5 50872F5 Bearing Adhesive* - - - - Adapters**: 3/40 Adapter 3/4" Adapter Washer 1° Adapter 1° Adapter Washer 1-1/2 Female Adapter 2° Female Adapter 95046 95014 - - - - - - 95063 95064 - - - - - - 95095 - - - - - - 95195 Order 3/40 Adapter 95046 and Adapter Washer 95038 to replace standard 3/4° disc meter, 9° long. Order 1" Adapter 95063 and Adapter Washer 95064 with Top Case 50566 to replace standard 1" disc meter, 10-3/4" long. Order 1-1/2" Adapter 95095 with Top Case 50776 to replace 1-1/2" female end meter installed with union connections. Assemble to length of 12-5/8". Order 2" Adapter 95195 with Top Case 50866 to replace standard 2° Female End disc meter, 15-1/4" long. *Purchase locally. Use a cyanoac,ylic adhesive, such as Loctite Super Bonder #30-13, Eastman #916, Permabond or Aron Alpha. **Must be ordered separately. Not an integral meter component. NOTE: If more than one part is required, quantity is noted after part number (in parenthesis). [=Mula,I1SYSMS LRJ@cM Visual Register Options Cubic Feet U.S. Gallons RFM Register Part Internal Relation to other Register Part Internal Relation to other Model Numbers Ratio Registers Numbers Ratio Registers RFM-30 B79821FS 551.99 -4% (in relation to B79825) B79813F5 738.92 -4% (in relation to B19817) RFM-30 B79822FS 546.34 -3% (in relation to 879825) B79814F5 731.88 -3% (in relation to B79817) RFM-30 879823FS 540.85 -2% (in relation to B79825) B79815FS 723.79 -2% (in relation to B79817) RFM-30 B79824F5 536.22 -1% (in relation to B79825) B79816F5 115.86 -1% (in relation to B79817) RFM-30 879825FS 530.07 - B79811FS 70901 1 - RFM-30 879826FS 523.96 +1% (in relation to B79825) B19818F5 702.61 +1% (in relation to B79817) RFM-30 B19827FS 519.6 +2% (in relation to B79825) B79819F5 694.85 +2% (in relation to 879817) RFM-30 879828FS 514.2 +3% (in relation to 879825) 879820FS 688.55 +3% (in relation to B79817) RFM-50 879861FS 269.44 -4% (in relation to B79865) 879851F5 360.58 -3% (in relation to B79 854) RFM-50 819862FS 266.44 -3% (in relation to B79865) B79852FS 356.41 -2% (in relation to B79854) RFTv1-50 879863FS 264.51 -2% (in relation to B79865) B79853FS 353.17 -1% (in relation to B19854) RFM-50 B79864FS 262.01 -1% (in relation to B79865) B79854F5 349.42 - RFM-50 B79865FS 258.83 - B79855FS 345.93 +1% (in relation to B79854) RFM-50 B79866FS 256.52 +1% (in relation to B79865) 819856FS 342.53 +2% (in relation to 879854) RFM-50 879867F5 254 +2% (in relation to 879865) 879857FS 339.04 +3% (in relation to B79854) RFM-100 B79901FS 1913.95 -3% (in relation to 879904) 879891F5 2664.16 -3% (in relation to 879894) RFM-100 B79902F5 1951.68 -2% (in relation to 879904) 879892FS 2646.98 -2% (in relation to B79894) RFM-100 B79903FS 1935.27 -1% (in relation to 819904) B79893F5 2605.61 -1% (in relation to B79894) RFM-100 B79904F5 1912.65 - B79894F5 2586.61 - RFM-100 B79905FS 1901.98 +1% (in relation to 879904) B79895FS 2554.55 +1% (in relation to 879894) RFM-100 B79906F5 1882.17 +2% (in relation to B79904) B79896FS 2526.66 +2% (in relation to 879894) RFM-100 B79907FS 1862.97 +3% (in relation to 879904) 879897FS 2505.78 +3% (in relation to B79894) RFM-160 879941F5 604.34 -3% (in relation to B79944) B79931FS 808.31 -3% (in relation to 879934) RFM-160 B79942FS 598.37 -2% (in relation to B19944) B79932FS 800.5 -2% (in relation to B79934) RFM-160 879943FS 592.81 -1% (in relation to 879944) B79933FS 792.41 -1% (in relation to 879934) RFM-160 B79944FS 587.03 - B19934FS 184.64 - RFM-160 B79945F5 580.58 1 +1% (in relation to 879944) 879935F5 775.87 +1% (in relation to B79934) JL_UM-160 L..79946FS 575.56 1 -i-2% (in relation to B79944) B79936FS1 768.47 1 +2% (in relation to 879934) WW4 nFN I Translator Register Options for RFM 30 to 160 ueller SYSTEMSI] 111 Ref Description RFM-30 RFM-50 RFM-100 RFM-160 1 Translator Register* Gallons Cubic Feet Specify Electronic Reading Value 4, 5, or Wheel D35231mm D35232mm D35241mm D35242om D35251xx D35252xxx 035261mm D35262xxx 2 Red Clamp Band (Plastic) Translator Only B8602FS B8602FS B8602FS B8602FS 3 Clamp Band Seal Nut 19999 19999 19999 19999 4 Clamp Band Seal Screw 19945 19945 19945 19945 5 Lens Terminal Cover Red B8441FS 88441F5 B8441FS B8447FS 6 Terminal Lug Screw 98197 (3) 98197 (3) 98197 (3) 98197 (3) 1 Wall Pad T1234 11234 T1234 T1234 8 Pit Pad T1240 11240 T1240 T1240 9 TrueRead (not shown) C6551G C6551G C6551G C6551G 10 1,000' Spool of Wire (not shown) AS755 A5755 AS755 AS155 *Call Mueller Systems Customer Service for appropriate Translator Register and AMR device part number. 0 Mueller Systems 03/25/2011 [MuIIr SYSTEMSI] This page intentionally left blank. 2URL WIUUNS Reduced Pressure Principle Assembly fM2Zt8---CA04-, Application Designed for installation on water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Standards Compliance ASSE® Listed 1013 IAPMO® Listed UL® Classified (less shut-off valves or with OS&Y valves C-UL® Classified CSA® Certified B64.4 AWWA compliant C511 Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California NYC MEA 425-89-M VOL 3 Materials Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA Approved) Buna Nitrile (FDA Approved) Polymers NorylTM, NSF Listed Springs Stainless Steel, 300 series Features Sizes: 3/4", 1°, 1-1/4, 1-1/2', 2° Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 Options (Suffixes can be combined) El - with full port QT ball valves (standard) El L - less ball valves, male pipe thread F-1 U - with union ball valves O MS - with integral relief valve monitor switch El S - with bronze "V type strainer El BMS - with battery operated monitor switch El FDC - with fire hydrant connection; 2" only El FT - with integral male 45° flare SAE test fitting El TCU - with test cocks up El V - with union swivel elbows (3/4" & 1°) El SE - with street elbows (3/4" & 1 ") Accessories El Air gap (Model AG) El Repair kits El Thermal expansion tank (Mdl. XI) El Soft seated check valve (Model 40XL) El Shock arrester (Model 1250XL) o OT-SET Quick Test Fitting Set El Ball valve handle locks Relief Valve discharge port: 3/4°-i" - 0.63 sq. in. 1 1/4"-2" - 1.19 sq. in. Dimensions & Weights (do not include pkg.) A G ___________ _____________ DIMENSIONS _(approximate) MODEL 975XL WITH BALL SIZE A C D E F G VALVES in. I mm in. mm in. mm in. mm in. mm in. mm in. I mm in. I mm lbs. I kg 3/4 20 12 305 73/4 197 21/8 54 3 76 31/2 89 5 127 161/8 410 12 5.5 1 25 13 330 73/4 197 21/8 54 3 76 31/2 89 5 127 173/8 441 14 6.4 11/4 32 17 432 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 229/16 573 28 12.7 11/2 40 173/8 441 1015/16 278 23/4 70 31/2 89 5 127 63/4 171 241/16 611 28 12.7 2 50 181/2 470 1015/16 278 23/4 70 31/2 89 5 127t6 3/4 171 261/2 673 34 15.4 Zurn Industries, LLC I Wilkins Rev. C 1747 commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 Date: 6/14 In Canada I Zum Industries Limited Document No. BF-975XL 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 Product No. Model 975XL www.zurn.com I Page 1 of 2 Ail Fkpi Characteristics ORated Flow (established by approval agencies) MODEL 975XL 3/4", 1", 11/4", 11/2" & 2" (STANDARD & METRIC) FLOW RATES (Ifs) 1.26 2.52 3.8 5.0 3.2 6.3 9.5 12.6 15.8 a. 4'I 1.1 -. '- JtJ11D • • [II I' FLOW RATES (GPM) (25mm) Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12" (305mm) and a maximum of 30" (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. CENTRAL STATION ALARM PANEL BATTERY MONITOR Capacity thru Schedule 40 Pipe Pipe size 5 ftlsec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8" 1 1 2 3 1/4" 2 2 3 5 3/8" 3 4 6 9 1/2" 5 7 9 14 3/4" 8 12 17 25 V. 13 20 27 40 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 52 78 105 167 PROTECTIVE ENCLOSURE 1Z MIN \l// 12'MtN LJL AIR GAP LJj AIR GAP / FITTING DRAIN FLOOR DRAIN I DIRECTION OF FLOW DIRECTION OF FLOW =D INLET SHUT-OFF INDOOR INSTALLATION OUTDOOR INSTALLATION (Shown w/optional BMS) Specifications The Reduced Pressure Principle Backflow Preventer shall be shall be ASSE® Listed 1013, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed NorylTM and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the installation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Back- flow Preventer shall be a ZURN WILKINS Model 975XL. Zum Industries, LLC I Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2