Loading...
HomeMy WebLinkAbout4390 ADAMS ST; ; FPR2017-0337; Permit:J r1r4j Iii 1I :Z'] FTI (City of Carlsbad Print Date: 08/30/2022 Job Address: 4390 ADAMS ST, CARLSBAD, CA 92008 Permit Type: FIRE-Construction Residential Work Class: Parcel #: 2061804000 Track #: Valuation: $587,550.29 Lot #: Occupancy Group: Project #: #of Dwelling Units: Plan #: Bedrooms: Construction Type: Bathrooms: Orig. Plan Check #: Plan Check #: Permit No: FPR2017-0337 Status: Closed - Finaled Single Family Fire Sprinki Applied: 10/03/2017 Issued: DEV2017-0061 Finaled Close Out: 03/09/2021 Final Inspection: INSPECTOR: Project Title: POLZIN RESIDENCE Description: POLZIN RESIDENCE - SFD SPRINKLER Applicant: FPContractor: SEXTON COMPANY INC SEXTON COMPANY INC BRENT SEXTON 12222 WOODSIDE AVE, # STE 132 12222 WOODSIDE AVE, # SUITE A - #132 LAKESIDE, CA 92040-3869 LAKESIDE, CA 92040-3868 (619) 454-6945 (619) 454-6945 FEE AMOUNT FIRE NFPA 13D Single Family System (Plan Review) $239.00 Total Fees: $239.00 Total Payments To Date: $239.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov P 'M TA~ .. V ..! 1hk Fire Protection by Computer Design Sexton Fire Protection 12222 Woodside Ave. # 132 Lakeside, Ca. 92040 619-454-6945 Job Name : Polzin Residence Building : Residence Location : 4390 Adam Street System I Contract : 4390 Data File : Design Area I .WXF FPR20I7-0337 4390 ADAMS ST Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 7 '-. Sexton lire Protection Page Poizin Residence Date 9-26-17 HYDRAULIC DESIGN INFORMATION SHEET Name - Poizin Residence Date - 9-26-17 Location - 4390 Adam Street Building - Residence System No. - 1 Contractor - Sexton Fire Protection Contract No. - 4390 Calculated By - Sexton Fire Protection Drawing No. - 4390 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )l (X)2 ( )4 S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Tyco Model LFII I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 160 N Calculation Gpm Required 27.93 Psi Required 49.525 TEST Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 80 R Residual (Psi) - 20 Flow (Gpm) - 500 S Elevation - P Location: P L Source of Information: Y Pump Data: Tank or Reservoir: Rated Cap. Cap. 8 Psi Elev. Elev. Other Well Proof Flow Gpm Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 F Water Supply Curve C Sexton Fire Protection Page 2 Polzin Residence Date 9-26-17 City Water Supply: Demand: Cl - Static Pressure : 72 Dl - Elevation : 13.686 C2 - Residual Pressure: 20 D2 - System Flow : 32.926 C2 - Residual Flow : 500 D2 - System Pressure : 65.495 Hose (Demand D3 - System Demand : 32.926 Safety Margin : 6.166 150 140 130 p120 R11° E100 s 9° 80 u 70 R 60 - - E 50 40 30 20 -D4-- 10 50 100 150 200 250 300 350 400 450 FLOW (N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C2 Fittings Used Summary Sexton Fire Protection Page 3 Polzin Residence Date 9-26-17 Fitting Legend Abbrev. Name '/ % 1 1/ 1/ 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 5* CPVC45Elbow 1 1 1 2 2 2 3 4 0 0 0 0 0 0 0 0 0 0 0 0 R* cPvccouplingTee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 13BO Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with . The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Sexton Fire Protection Page 4 Poizin Residence Date 9-26-17 Node No. Elevation K-Fact Pt Actual Pn Flow Density Actual Area Press Req. HI 31.6 4.9 9.28 na 14.93 0.05 256 7.0 H2 31.6 4.9 7.04 na 13.0 0.05 256 7.039 H3 21.6 23.44 na H4 21.6 16.92 na H5 21.6 16.92 na Dl 32.6 9.82 na 1 32.6 11.97 na 2 32.6 13.25 na 3 32.6 16.79 na 4 22.6 23.01 na 5 10.6 30.35 na 6 10.6 34.64 na D2 32.6 7.36 na 1.1 32.6 8.12 na 1.2 32.6 11.48 na 1.3 32.6 12.15 na 03 23.6 22.58 na 101 23.6 22.58 na 102 23.6 22.58 na 103 23.6 22.58 na 104 23.6 22.58 na D4 23.6 16.05 na D5 23.6 16.05 na 201 23.6 16.05 na 202 23.6 16.05 na TOR 10.6 40.03 na BOR 2.0 49.53 na 5.0 UGI 0.0 51.03 na METE 0.0 55.97 na TEST 0.0 65.5 na The maximum velocity is 13.59 and it occurs in the pipe between nodes METE and TEST Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Anl Calculations - Hazen-Williams Sexton Fire Protection Page 5 Polzin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn HI 14.93 0.874 N 7.0 1.000 9.278 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 DI 14.93 0.1219 0.0 8.000 0.975 Vel = 7.98 0.0 14.93 9.820 K Factor= 4.76 H2 13.00 0.874 N 7.0 1.000 7.039 K Factor = 4.90 to 150.0 0.0 7.000 -0.433 D2 13.0 0.0944 0.0 8.000 0.755 Vel = 6.95 0.0 13.00 7.361 KFactor= 4.79 H3 0.0 0.874 N 7.0 1.000 23.444 to 150.0 0.0 7.000 -0.866 D3 0.0 -0.0001 0.0 8.000 -0.001 Vel = 0 0.0 0.0 22.577 K Factor =0 H4 0.0 0.874 N 7.0 1.000 16.916 to 150.0 0.0 7.000 -0.866 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 16.050 K Factor = 0 H5 0.0 0.874 N 7.0 1.000 16.916 to 150.0 0.0 7.000 -0.866 D5 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 16.050 K Factor = 0 Dl 14.93 0.874 N 7.0 7.667 9.820 to 150.0 0 3.0 10.000 0.0 1 14.93 0.1219 0.0 17.667 2.154 Vel = 7.98 I 0.0 0.874 R 1.0 6.500 11.974 to 150.0 0 3.0 4.000 0.0 2 14.93 0.1219 0.0 10.500 1.280 Vel = 7.98 2 13.00 1.101 R 1.0 13.000 13.254 to 150.0 2N 14.0 15.000 0.0 3 27.93 0.1262 0.0 28.000 3.533 Vel = 9.41 3 0.0 1.101 0 5.0 10.000 16.787 to 150.0 0.0 5.000 4.331 4 27.93 0.1261 0.0 15.000 1.892 Vel = 9.41 4 0.0 1.101 N 7.0 10.000 23.010 to 150.0 0.0 7.000 5.197 5 27.93 0.1262 0.0 17.000 2.146 Vel = 9.41 5 0.0 1.101 2P 2.0 24.000 30.353 to 150.0 3R 3.0 10.000 0.0 6 27.93 0.1262 0 5.0 34.000 4.290 Vel = 9.41 6 0.0 1.101 2N 14.0 26.667 34.643 to 150.0 2R 2.0 16.000 0.0 TOR 27.93 0.1262 0.0 42.667 5.383 Vel = 9.41 0.0 27.93 40.026 K Factor= 4.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fi,l Calculations - Hazen-Williams Sexton Fire Protection Page 6 Poizin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 02 13.00 0.874 0 3.0 5.083 7.361 to 150.0 0.0 3.000 0.0 1.1 13.0 0.0944 0.0 8.083 0.763 Vel = 6.95 1.1 0.0 0.874 2R 2.0 23.583 8.124 to 150.0 N 7.0 12.000 0.0 1.2 13.0 0.0944 0 3.0 35.583 3.360 Vel = 6.95 1.2 0.0 0.874 0 3.0 4.083 11.484 to 150.0 0.0 3.000 0.0 1.3 13.0 0.0943 0.0 7.083 0.668 Vel = 6.95 1.3 -13.00 0.874 N 7.0 2.167 12.152 to 150.0 0.0 7.000 14.119 203 0.0 0.0001 0.0 9.167 0.001 Vel = 0 0.0 0.0 26.272 K Factor = 0 1.3 13.00 0.874 0 3.0 8.667 12.152 to 150.0 0.0 3.000 0.0 2 13.0 0.0945 0.0 11.667 1.102 Vel = 6.95 0.0 13.00 13.254 K Factor= 3.57 03 0.0 0.874 0 3.0 3.333 22.577 to 150.0 0.0 3.000 0.0 101 0.0 0.0 0.0 6.333 0.0 Vel = 0 101 0.0 0.874 2R 2.0 15.000 22.577 to 150.0 0 3.0 5.000 0.0 102 0.0 0.0 0.0 20.000 0.0 Vel = 0 102 0.0 1.101 4R 4.0 29.000 22.577 to 150.0 N 7.0 11.000 0.0 103 0.0 0.0 0.0 40.000 0.0 Vel = 0 103 0.0 1.101 3N 21.0 35.083 22.577 to 150.0 3R 3.0 24.000 0.0 104 0.0 0.0 0.0 59.083 0.0 Vel = 0 104 0.0 1.101 2N 14.0 5.583 22.577 to 150.0 0 5.0 19.000 0.433 4 0.0 0.0 0.0 24.583 0.0 Vel = 0 0.0 0.0 23.010 K Factor =0 D4 0.0 0.874 0 3.0 11.417 16.050 to 150.0 0.0 3.000 0.0 201 0.0 0.0 0.0 14.417 0.0 Vel = 0 0.0 0.0 16.050 K Factor = 0 D5 0.0 0.874 0 3.0 2.833 16.050 to 150.0 0.0 3.000 0.0 201 0.0 0.0 0.0 5.833 0.0 Vel = 0 201 0.0 1.101 N 7.0 4.083 16.050 to 150.0 0.0 7.000 0.0 202 0.0 0.0 0.0 11.083 0.0 Vel = 0 202 0.0 1.101 N 7.0 10.000 16.050 to 150.0 0.0 7.000 10.221 203 0.0 0.0001 0.0 17.000 0.001 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Sextori Fire Protection Page 7 Polzin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C" or Ftng's Pe Pv Notes Point at Pf/Ft Eqv. Ln. Total Pf Pn 0.0 0.0 26.272 K Factor = 0 TOR 27.93 1.101 Fsp 0.0 8.600 40.026 to 150.0 S 9.563 13.387 6.725 * * Fixed Loss = 3 BOR 27.93 0.1262 E 3.825 21.987 2.774 Vel = 9.41 BOR 5.00 1.505 T 8.704 4.000 49.525 Qa = 5.00 to 150.0 E 4.352 13.057 0.866 UG1 32.93 0.0373 0.0 17.057 0.637 Vel = 5.94 UGI 0.0 1.61 0.0 35.000 51.028 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 METE 32.93 0.0269 0.0 35.000 0.941 Vel = 5.19 METE 0.0 0.995 0.0 34.000 55.969 to 150.0 0.0 0.0 0.0 TEST 32.93 0.2802 0.0 34.000 9.526 Vel = 13.59 0.0 32.93 65.495 K Factor= 4.07 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fire Protection by Computer Design Sexton Fire Protection 12222 Woodside Ave. # 132 Lakeside, Ca. 92040 619-454-6945 Job Name Polzin Residence Building : Residence Location : 4390 Adam Street System : 1 Contract : 4390 Data File Design Area 2.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Sexton Fire Protection Poizin Residence HYDRAULIC DESIGN INFORMATION SHEET Name - Polzin Residence Date - 9-26-17 Location - 4390 Adam Street Building - Residence System No. - 1 Contractor - Sexton Fire Protection Contract No. - 4390 Calculated By - Sexton Fire Protection Drawing No. - 4390 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD Page 1 Date 9-26-17 S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: (x)1 ( )2 ( )4 S ( )Other T ( )Specific Ruling Made by Date E M Listed Flow at Start Point - 20 Gpm System Type Listed Pres. at Start Point - 16.7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 20 x 20 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Tyco Model LFII I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 160 N Calculation Gpm Required 20.02 Psi Required 51.716 TEST Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - Rated Cap. Cap. T Time of Test - @ Psi Elev. E Static (Psi) - 80 Elev. R Residual (Psi) - 20 Other Well Flow (Gpm) - 500 Proof Flow Gpm S Elevation - P Location: P L Source of Information: Y Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Sexton Fire Protection Page 2 Poizin Residence Date 9-26-17 City Water Supply: Demand: Cl - Static Pressure : 72 Dl - Elevation : 9.355 C2 - Residual Pressure: 20 02 - System Flow : 25.024 C2 - Residual Flow : 500 02 - System Pressure : 63.266 Hose ( Demand) D3 - System Demand : 25.024 Safety Margin : 8.530 150 140 130 p120 R° E10° s 90 80 U70 60 E 50 - _______ _________ __________ 40 30 - 20 10 - ,.... ., 50 100 150 200 250 300 350 400 450 FLOW (N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C2 Fittings Used Summary Sexton Fire Protection Page 3 Poizin Residence Date 9-26-17 Fitting Legend Abbrev. Name '/ % 1 1/ 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E NFPA 1390, Standard Elbow I 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N * CPVC 90EII Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 P CPVC45'Elbow 1 1 1 2 2 2 3 4 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplinglee - Run I I I 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Sexton Fire Protection Polzin Residence Node No. Elevation K-Fact Pt Actual Pn Hi 31.6 28.01 na H2 31.6 28.01 na H3 21.6 4.9 16.7 na H4 21.6 32.34 na H5 21.6 32.34 na Di 32.6 27.58 na 1 32.6 27.58 na 2 32.6 27.58 na 3 32.6 27.58 na 4 22.6 31.91 na 5 10.6 38.26 na 6 10.6 40.58 na D2 32.6 27.58 na 1.1 32.6 27.58 na 1.2 32.6 27.58 na 1.3 32.6 27.58 na D3 23.6 17.51 na 101 23.6 18.84 na 102 23.6 23.04 na 103 23.6 25.77 na 104 23.6 29.8 na D4 23.6 31.47 na D5 23.6 31.47 na 201 23.6 31.47 na 202 23.6 31.47 na TOR 10.6 43.49 na BOR 2.0 51.72 na UG1 0.0 52.97 na METE 0.0 57.53 na TEST 0.0 63.27 na The maximum velocity is 10.71 and it occurs in the pipe between nodes H3 and D3 Page 4 Date 9-26-17 Flow Density Area Press Actual Req. 20.02 0.05 400 16.7 5.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fin 'I Calculations - Hazen-Williams Sexton Fire Protection Page 5 Polzin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn Hi 0.0 0.874 N 7.0 1.000 28.010 to 150.0 0.0 7.000 -0.433 Di 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 27.577 K Factor = 0 H2 0.0 0.874 N 7.0 1.000 28.010 to 150.0 0.0 7.000 -0.433 D2 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 27.577 K Factor = 0 H3 20.02 0.874 N 7.0 1.000 16.700 K Factor =4.90 to 150.0 0.0 7.000 -0.866 D3 20.02 0.2099 0.0 8.000 1.679 Vel = 10.71 0.0 20.02 17.513 K Factor = 4.78 H4 0.0 0.874 N 7.0 1.000 32.341 to 150.0 0.0 7.000 -0.866 D4 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 31.475 K Factor = 0 H5 0.0 0.874 N 7.0 1.000 32.341 to 150.0 0.0 7.000 -0.866 D5 0.0 0.0 0.0 8.000 0.0 Vel = 0 0.0 0.0 31.475 K Factor = 0 Di 0.0 0.874 N 7.0 7.667 27.577 to 150.0 0 3.0 10.000 0.0 1 0.0 0.0 0.0 17.667 0.0 Vel = 0 1 0.0 0.874 R 1.0 6.500 27.577 to 150.0 0 3.0 4.000 0.0 2 0.0 0.0 0.0 10.500 0.0 Vel = 0 2 0.0 1.101 R 1.0 13.000 27.577 to 150.0 2N 14.0 15.000 0.0 3 0.0 0.0 0.0 28.000 0.0 Vel = 0 3 0.0 1.101 0 5.0 10.000 27.577 to 150.0 0.0 5.000 4.331 4 0.0 0.0 0.0 15.000 0.0 Vel = 0 4 20.02 1.101 N 7.0 10.000 31.908 to 150.0 0.0 7.000 5.197 5 20.02 0.0682 0.0 17.000 1.159 Vel = 6.75 5 0.0 1.101 2P 2.0 24.000 38.264 to 150.0 3R 3.0 10.000 0.0 6 20.02 0.0682 0 5.0 34.000 2.319 Vel = 6.75 6 0.0 1.101 2N 14.0 26.667 40.583 to 150.0 2R 2.0 16.000 0.0 TOR 20.02 0.0682 0.0 42.667 2.909 Vel = 6.75 0.0 20.02 43.492 K Factor = 3.04 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 LFinal Calculations - Hazen-Williams Sexton Fire Protection Page 6 Poizin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftngs Pe Pv Notes Point at Pf/Ft Eqv. Ln. Total Pf Pn D2 0.0 0.874 0 3.0 5.083 27.577 to 150.0 0.0 3.000 0.0 1.1 0.0 0.0 0.0 8.083 0.0 Vel = 0 1.1 0.0 0.874 2R 2.0 23.583 27.577 to 150.0 N 7.0 12.000 0.0 1.2 0.0 0.0 0 3.0 35.583 0.0 Vel = 0 1.2 0.0 0.874 0 3.0 4.083 27.577 to 150.0 0.0 3.000 0.0 1.3 0.0 0.0 0.0 7.083 0.0 Vel = 0 1.3 0.0 0.874 N 7.0 2.167 27.577 to 150.0 0.0 7.000 14.119 203 0.0 0.0 0.0 9.167 0.0 Vel = 0 0.0 0.0 41.696 K Factor = 0 1.3 0.0 0.874 0 3.0 8.667 27.577 to 150.0 0.0 3.000 0.0 2 0.0 0.0 0.0 11.667 0.0 Vel = 0 0.0 0.0 27.577 K Factor = 0 D3 20.02 0.874 0 3.0 3.333 17.513 to 150.0 0.0 3.000 0.0 101 20.02 0.2100 0.0 6.333 1.330 Vel = 10.71 101 0.0 0.874 2R 2.0 15.000 18.843 to 150.0 0 3.0 5.000 0.0 102 20.02 0.2100 0.0 20.000 4.199 Vel = 10.71 102 0.0 1.101 4R 4.0 29.000 23.042 to 150.0 N 7.0 11.000 0.0 103 20.02 0.0682 0.0 40.000 2.727 Vel = 6.75 103 0.0 1.101 3N 21.0 35.083 25.769 to 150.0 3R 3.0 24.000 0.0 104 20.02 0.0682 0.0 59.083 4.029 Vel = 6.75 104 0.0 1.101 2N 14.0 5.583 29.798 to 150.0 0 5.0 19.000 0.433 4 20.02 0.0682 0.0 24.583 1.677 Vel = 6.75 0.0 20.02 31.908 K Factor = 3.54 D4 0.0 0.874 0 3.0 11.417 31.475 to 150.0 0.0 3.000 0.0 201 0.0 0.0 0.0 14.417 0.0 Vel = 0 0.0 0.0 31.475 K Factor = 0 D5 0.0 0.874 0 3.0 2.833 31.475 to 150.0 0.0 3.000 0.0 201 0.0 0.0 0.0 5.833 0.0 Vel = 0 201 0.0 1.101 N 7.0 4.083 31.475 to 150.0 0.0 7.000 0.0 202 0.0 0.0 0.0 11.083 0.0 Vel = 0 202 0.0 1.101 N 7.0 10.000 31.475 to 150.0 0.0 7.000 10.221 203 0.0 0.0 0.0 17.000 0.0 Vel = 0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Sexton Fire Protection Page 7 Poizin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 0.0 41.696 K Factor =0 TOR 20.02 1.101 Fsp 0.0 8.600 43.492 to 150.0 S 9.563 13.387 6.725 * * Fixed Loss = 3 BOR 20.02 0.0682 E 3.825 21.987 1.499 Vel = 6.75 BOR 5.00 1.505 T 8.704 4.000 51.716 Qa= 5.00 to 150.0 E 4.352 13.057 0.866 UGI 25.02 0.0225 0.0 17.057 0.384 Vet = 4.51 UGI 0.0 1.61 0.0 35.000 52.966 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 METE 25.02 0.0162 0.0 35.000 0.566 Vel = 3.94 METE 0.0 0.995 0.0 34.000 57.532 to 150.0 0.0 0.0 0.0 TEST 25.02 0.1686 0.0 34.000 5.734 Vet = 10.32 0.0 25.02 63.266 K Factor = 3.15 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 F.TFAINLI.I.Re Fire Protection by Computer Design Sexton Fire Protection 12222 Woodside Ave. # 132 Lakeside, Ca. 92040 619-454-6945 Job Name Polzin Residence Building Residence Location : 4390 Adam Street System : I Contract : 4390 Data File : Design Area 3.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Sexton Fire Protection Page 1 Poizin Residence Date 9-26-17 HYDRAULIC DESIGN INFORMATION SHEET Name - Polzin Residence Date - 9-26-17 Location - 4390 Adam Street Building - Residence System No. - 1 Contractor - Sexton Fire Protection Contract No. - 4390 Calculated By - Sexton Fire Protection Drawing No. - 4390 Construction: (X) Combustible ( ) Non-Combustible Ceiling Height OCCUPANCY - LIGHT HAZARD S Type of Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Y Number of Sprinklers Flowing: ( )l (X)2 ( )4 S ( )Other T ( )Specific Ruling Made by Date E N Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 7 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 ( ) Deluge ( ) PreAction E Domestic Flow Added - +5 Gpm Sprinkler or Nozzle S Additional Flow Added - Gpm Make Tyco Model LFII I Elevation at Highest Outlet - Feet Size 7/16" K-Factor 4.9 G Note: Temperature Rating 160 N Calculation Gpm Required 26.62 Psi Required 49.624 TEST Summary C-Factor Used: Overhead 150 Underground 150 W Water Flow Test: A Date of Test - T Time of Test - E Static (Psi) - 80 R Residual (Psi) - 20 Flow (Gpm) - 500 S Elevation - P Location: P L Source of Information: Y Pump Data: Tank or Reservoir: Rated Cap. Cap. @ Psi Elev. Elev. Other Well Proof Flow Gpm Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Water Supply Curve C Sexton Fire Protection Page 2 Poizin Residence Date 9-26-17 City Water Supply: Demand: Cl - Static Pressure : 72 Dl - Elevation : 9.355 C2 - Residual Pressure: 20 D2 - System Flow : 31.625 C2 - Residual Flow : 500 D2 - System Pressure : 64.796 Hose ( Demand) D3 - System Demand : 31.625 Safety Margin : 6.889 150 - - 140 130 p120 R° E10° S90 s 8° U 70 Ut R 60 -. E 50 40 30 - - _ 20 10 50 100 150 200 250 300 350 400 450 FLOW (NA 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 C2 Fittings Used Summary Sexton Fire Protection Polzin Residence Page 3 Date 9-26-17 Fitting Legend Abbrev. Name % 1 1'/ 1% 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow N • cpvc 90Eli Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0 0. CPVCTee - Brsnch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0 P CPVC45Elbow 1 1 1 2 2 2 3 4 0 0 0 0 0 0 0 0 0 0 0 0 R* CPVCCouplingTee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 139O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with *• The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD Sexton Fire Protection Page 4 Poizin Residence Date 9-26-17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. Hi 31.6 15.48 na H2 31.6 11.33 na H3 21.6 24.78 na H4 21.6 4.9 7.04 na 13.0 0.05 256 7.039 H5 21.6 4.9 7.73 na 13.62 0.05 256 7.0 Di 32.6 15.04 na 32.6 15.04 na 2 32.6 15.04 na 3 32.6 18.28 na 4 22.6 24.34 na 5 10.6 31.5 na 6 10.6 35.43 na D2 32.6 10.9 na 1.1 32.6 10.9 na 1.2 32.6 10.9 na 1.3 32.6 10.9 na D3 23.6 23.91 na 101 23.6 23.91 na 102 23.6 23.91 na 103 23.6 23.91 na 104 23.6 23.91 na D4 23.6 6.93 na D5 23.6 7.69 na 201 23.6 8.29 na 202 23.6 9.57 na TOR 10.6 40.36 na BOR 2.0 49.62 na 5.0 UG1 0.0 51.08 na METE 0.0 55.95 na TEST 0.0 64.8 na The maximum velocity is 14.24 and it occurs in the pipe between nodes 1.3 and 203 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Sexton Fire Protection Page 5 Potzin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point at Pf/Ft Eqv. Ln. Total Pf Pn HI 0.0 0.874 N 7.0 1.000 15.477 to 150.0 0.0 7.000 -0.433 DI 0.0 0.0 0.0 8.000 0.0 Vet = 0 0.0 0.0 15.044 K Factor =0 H2 0.0 0.874 N 7.0 1.000 11.328 to 150.0 0.0 7.000 -0.433 D2 0.0 0.0 0.0 8.000 0.0 Vet = 0 0.0 0.0 10.895 K Factor =0 H3 0.0 0.874 N 7.0 1.000 24.776 to 150.0 0.0 7.000 -0.866 D3 0.0 -0.0001 0.0 8.000 -0.001 Vet = 0 0.0 0.0 23.909 K Factor = 0 H4 13.00 0.874 N 7.0 1.000 7.039 K Factor =4.90 to 150.0 0.0 7.000 -0.866 D4 13.0 0.0944 0.0 8.000 0.755 Vet = 6.95 0.0 13.00 6.928 K Factor = 4.94 H5 13.62 0.874 N 7.0 1.000 7.731 K Factor =4.90 to 150.0 0.0 7.000 -0.866 D5 13.62 0.1030 0.0 8.000 0.824 Vet = 7.28 0.0 13.62 7.689 K Factor = 4.91 Dl 0.0 0.874 N 7.0 7.667 15.044 to 150.0 0 3.0 10.000 0.0 1 0.0 0.0 0.0 17.667 0.0 Vet = 0 1 0.0 0.874 R 1.0 6.500 15.044 to 150.0 0 3.0 4.000 0.0 2 0.0 0.0 0.0 10.500 0.0 Vet = 0 2 26.62 1.101 R 1.0 13.000 15.044 to 150.0 2N 14.0 15.000 0.0 3 26.62 0.1155 0.0 28.000 3.235 Vet = 8.97 3 0.0 1.101 0 5.0 10.000 18.279 to 150.0 0.0 5.000 4.331 4 26.62 0.1155 0.0 15.000 1.732 Vet = 8.97 4 0.0 1.101 N 7.0 10.000 24.342 to 150.0 0.0 7.000 5.197 5 26.62 0.1155 0.0 17.000 1.964 Vet = 8.97 5 0.0 1.101 2P 2.0 24.000 31.503 to 150.0 3R 3.0 10.000 0.0 6 26.62 0.1155 0 5.0 34.000 3.928 Vet = 8.97 6 0.0 1.101 2N 14.0 26.667 35.431 to 150.0 2R 2.0 16.000 0.0 TOR 26.62 0.1155 0.0 42.667 4.929 Vet = 8.97 0.0 26.62 40.360 K Factor = 4.19 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Sexton Fire Protection Page 6 Poizin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 'C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D2 0.0 0.874 0 3.0 5.083 10.895 to 150.0 0.0 3.000 0.0 1.1 0.0 0.0 0.0 8.083 0.0 Vel = 0 1.1 0.0 0.874 2R 2.0 23.583 10.895 to 150.0 N 7.0 12.000 0.0 1.2 0.0 0.0 0 3.0 35.583 0.0 Vel = 0 1.2 0.0 0.874 0 3.0 4.083 10.895 to 150.0 0.0 3.000 0.0 1.3 0.0 0.0 0.0 7.083 0.0 Vel = 0 1.3 -26.62 0.874 N 7.0 2.167 10.895 to 150.0 0.0 7.000 14.119 203 -26.62 -0.3556 0.0 9.167 -3.260 Vel = 14.24 0.0 -26.62 21.754 K Factor= -5.71 1.3 26.62 0.874 0 3.0 8.667 10.895 to 150.0 0.0 3.000 0.0 2 26.62 0.3556 0.0 11.667 4.149 Vel = 14.24 0.0 26.62 15.044 K Factor = 6.86 03 0.0 0.874 0 3.0 3.333 23.909 to 150.0 0.0 3.000 0.0 101 0.0 0.0 0.0 6.333 0.0 Vel = 0 101 0.0 0.874 2R 2.0 15.000 23.909 to 150.0 0 3.0 5.000 0.0 102 0.0 0.0 0.0 20.000 0.0 Vel = 0 102 0.0 1.101 4R 4.0 29.000 23.909 to 150.0 N 7.0 11.000 0.0 103 0.0 0.0 0.0 40.000 0.0 Vel = 0 103 0.0 1.101 3N 21.0 35.083 23.909 to 150.0 3R 3.0 24.000 0.0 104 0.0 0.0 0.0 59.083 0.0 Vel = 0 104 0.0 1.101 2N 14.0 5.583 23.909 to 150.0 0 5.0 19.000 0.433 4 0.0 0.0 0.0 24.583 0.0 Vel = 0 0.0 0.0 24.342 K Factor = 0 04 13.00 0.874 0 3.0 11.417 6.928 to 150.0 0.0 3.000 0.0 201 13.0 0.0944 0.0 14.417 1.361 Vel = 6.95 0.0 13.00 8.289 K Factor = 4.52 05 13.62 0.874 0 3.0 2.833 7.689 to 150.0 0.0 3.000 0.0 201 13.62 0.1029 0.0 5.833 0.600 Vel = 7.28 201 13.00 1.101 N 7.0 4.083 8.289 to 150.0 0.0 7.000 0.0 202 26.62 0.1155 0.0 11.083 1.280 Vel = 8.97 202 0.0 1.101 N 7.0 10.000 9.569 to 150.0 0.0 7.000 10.221 203 26.62 0.1155 0.0 17.000 1.964 Vel = 8.97 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Sexton Fire Protection Page 7 Poizin Residence Date 9-26-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C' or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 26.62 21.754 K Factor = 5.71 TOR 26.62 1.101 Fsp 0.0 8.600 40.360 to 150.0 S 9.563 13.387 6.725 * * Fixed Loss = 3 BOR 26.62 0.1155 E 3.825 21.987 2.539 Vel = 8.97 BOR 5.00 1.505 T 8.704 4.000 49.624 Qa = 5.00 to 150.0 E 4.352 13.057 0.866 UGI 31.62 0.0346 0.0 17.057 0.591 Vel = 5.70 UG1 0.0 1.61 0.0 35.000 51.081 to 150.0 0.0 0.0 4.000 * * Fixed Loss = 4 METE 31.62 0.0250 0.0 35.000 0.874 Vel = 4.98 METE 0.0 0.995 0.0 34.000 55.955 to 150.0 0.0 0.0 0.0 TEST 31.62 0.2600 0.0 34.000 8.841 Vel = 13.05 0.0 31.62 64.796 K Factor = 3.93 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 tqcly /fire &BUiidllng I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster ® CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet An rapid response HOME FIRE SPRINKLER SYSTEM General Description Tyco® CPVC Pipe and Fittings pro- duced by Tyco Fire & Building Prod- ucts (TFBP) are designed exclusively for use in wet pipe automatic fire sprin- kler systems. The Tyco CPVC Pipe and Fittings are produced from Blaze- Master® CPVC compound that is a specially developed thermoplastic compound composed of post chlorin- ated polyvinyl chloride (CPVC) resin and state of the art additives. Tyco CPVC Pipe and Fittings are easier to install than traditional steel pipe sys- tems, and at the same time, provide superior heat resistance and strength as compared to traditional CPVC and PVC piping materials used in the plumbing trade. Various adapters are available to connect CPVC pipe to me- tallic piping. All female pipe thread adapters have brass inserts for dura- bility. Grooved adapters connect di- rectly to grooved end valves and me- tallic pipe, with flexible grooved end couplings. Tyco® CPVC Pipe and Fittings pro- duced with BlazeMastet CPVC com- pound described herein must be in- stalled and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may im- pair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, C-UL, NSF, LPCB, MEA, and the City of Los Angeles. (Refer to In- stallation Handbook IH-1900 dated June 2008 for exact listing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMaster'5 is a registered trademark of The Lubrizol Corporation Page 1 of 2 JUNE, 2008 TFPI9I5 I , Page 2 of 2 TFPI9I5 Installation Tyco® CPVC Pipe and Fittings pro- duced by Tyco Fire & Building Prod- ucts (TFBP) are to be installed in accordance with Installation Hand- book IH-1900 dated June 2008. Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accord- ance with local requirements and/or national codes. NOTlCE Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system in service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. [it!1EII1uiuIe]f! This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. © 2008 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 eqx~o) Fire Protection Products Worldwide I www.tyco-fire.com Contacts RAPID RESPONSE Series LFII Residential 49 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Concealed Pendent Sprinklers (TY3596) are decorative, fast response, fusible solder sprinklers designed for use in residential occu- pancies such as homes, apartments, dormitories, and hotels. The cover plate assembly conceals the sprinkler operating components above the ceiling. The flat profile of the cover plate provides the optimum aes- thetically appealing sprinkler design. In addition, the concealed design of the Series LFll Residential Concealed Pendent Sprinklers (TY3596) provides 1/2 inch (12,7 mm) vertical adjustment. This adjustment provides a measure of flexibility when cutting fixed sprinkler drops. The Series LFII Residential Concealed Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 The Series LFII Residential Concealed Pendent Sprinklers (TY3596) has been designed with heat sensitivity and water distribution characteristics proven to help in the control of residen- tial fires and to improve the chance for occupants to escape or be evacuated. The Series LFII Residential Con- cealed Pendent Sprinklers (TY3596) are shipped with a Disposable Pro- tective Cap. The Protective Cap is temporarily removed for installation, and then it can be replaced to help protect the sprinkler while the ceiling is being installed or finished. The tip of the Protective Cap can also be used to mark the center of the ceiling hole into plaster board, ceiling tiles, etc. by gently pushing the ceiling product against the Protective Cap. When the ceiling installation is complete the Pro- tective Cap is removed and the Cover Plate Assembly installed. Dry Pipe System Application The Series LFII Residential Concealed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprinkler systems, whereas, most residential sprinklers are labora- tory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Concealed Pendent Sprinklers (TY3596) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. FEBRUARY 2015 NOTICE The Series LFII Residential Concealed Pendent Sprinklers (TY3596) described herein must be installed and main- tained in compliance with this docu- ment and with the applicable standards of the National Fire Protection Associa- tion (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3596 TFP442 TFP442 Page 2 of 6 BODY (1/2 NPT) - CAP SADDLE - SUPPORT CUP WITH - ROLL FORMED THREADS GUIDE PIN GUIDE PIN HOUSING DEFLECTOR - THREAD INTO SUPPORT CUP UNTIL MOUNTING SURFACE IS FLUSH WITH CEILING SEALING ASSEMBLY SPRINKLER WRENCHING AREA COMPRESSION SCREW LEVER SOLDER LINK I ELEMENT I I I I I II I I I I I I DEFLECTOR I (OPERATED POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY RETAINER WITH THREAD - DIMPLES JECTION SPRING / F/ WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 2 W-TYPE 18 SPRINKLER WRENCH SOLDER - COVER PLATE/RETAINER TAB ASSEMBLY FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) COVER- SPRINKLER- RETAINER SUPPORT CUP ASSEMBLY ASSEMBLY - COVER PLATE SPRINKLER- SUPPORT CUP =-/ ASSEMBI OPERATE SPRINKLE COVER PLATE RETAINE 7/8 (22,2 n 1-1/8 (28,6 1/2 (12,7 mm) FACE OF THREADED SPRINKLER ADJUSTMENT FITTING 1-7/8±1/4 (47,6 mm ±6,4 mm) El MOUNTING SURFACE 2-1/2 DIA. 63,5 mm) 1/2 NPT.. _____ 3-3/16 DIA. / DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Data Approvals UL and C-UL Listed NYC Approved under MEA 44-03-E-2NSF Certified to NSF/ANSI 61 The TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprinklers are only Listed with the Series LFII Con-cealed Cover Plates having a factory-ap-plied finish. Cover Plates can be ordered by following the instructions in the Ordering Procedure section. Maximum Working Pressure 175 psi (12,1 bar) Discharge Cfficient K=4.9 gpm/psi (70,6 pm/bar1 /2) Temperature Rating 160°F (71°C) Sprinkler with 139°F (59°C) Cover Plate Vertical Adjustment 1/2 inch (12,7 mm) Finishes Refer to Ordering Procedure section Physical Characteristics Body.........................Brass Cap.........................Bronze Saddle .......................Brass Sealing Assembly.......Beryllium Nickel w/TEFLON Soldered Link Halves............Nickel Lever........................Bronze Compression Screw.............Brass Deflector...................Copper or Brass Guide Pin Housing .............Bronze Guide Pins .............Stainless Steel or Bronze Support Cup ...................Steel Cover Plate ..................Copper Retainer ......................Brass Cover Plate Ejection Spring..........Stainless Steel Operation When exposed to heat from a fire, the Cover Plate, which is normally soldered to the Support Cup at three points, falls away to expose the sprinkler assembly. At this point the Deflector supported by the Arms drops down to its operated position. The fusible link of the sprin- kler assembly is comprised of two link halves that are soldered together with a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate allowing the sprinkler to activate and flow water. Design Criteria TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) are UL and C-UL Listed for installation in accordance with this section. Note: When conditions exist that are outside the scope of the provided cri- teria, refer to the Residential Sprinkler Design Guide TFP490 for the manu- facturer's recommendations that may be acceptable to the authority having jurisdiction. System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 about the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13 as applicable. Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 13D or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: the flow rates given in Tables A and B as a function of temperature rat- ing and the maximum allowable cov- erage area a minimum discharge of 0.1 gpm/ft.2 over the design area comprised of the four (4) most hydraulically demanding sprinklers for actual coverage areas protected by the four (4) sprinklers The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residen- tial Concealed Pendent Sprinklers (TY3596) in dry pipe sprinkler systems, the time for water delivery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity The sprinklers are to be installed rela- tive to the ceiling mounting surface as shown in Figure 3. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Ref. Table A or B) being hydraulically calculated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). The Series LFII must not be used in applications where the air pres- sure above the ceiling is greater than that below. Down drafts through the Support Cup could delay sprinkler operation in a fire situation. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure2'3 Maximum Coverage Maximum Spacing Ordinary Temp. Rating Area 160°F (71°C) Minimum Ft. x Ft. Ft. (m) Deflector to Installation Spacing Flow Pressure (mxm) Ceiling Type Ft. gpm psi (m) (1pm) (bar) 12x12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 13 7.0 inches (4,3x4,3) (4,3) (49,2) (0,48) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 13 7.0 (4,9x4,9) (4,9) (49,2) (0,48) 13R, or 13. Installed in (2,4) 18x18 18 17 12.0 beam (5,5x5,5) (5,5) (64,3) (0,83) 7/8to1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x6,1) (6,1) (75,7) (1,15) beam Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (lpm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpmJft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure 2,3 Maximum Maximum Coverage Area Spacing Ordinary Temp. Rating 160°F (71°C) Minimum Ft. x Ft. Ft. Deflector to Installation Spacing Flow Pressure (m x m) (m) Ceiling Type Ft. gpm 3SI (m) (1pm) (bar) 12x12 12 13 7.0 Smooth (3,7 X 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14x14 14 14 8.2 inches (4,3x4,3) (4,3) (53,0) (0,57) Beamed Ceilings per NFPA 13D or Concealed 8 16 x 16 16 15 94 (4,9x4,9) (4,9) (56,8) (0,65) 13R, or 13. Installed in (2,4) 18x18 18 18 13.5 beam (5,5x5,5) (5,5) (68,1) (0,93) 7/8to1-1/8 inches below bottom of 20 x 20 20 21 18.4 (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpn, (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.' over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 I It Installation TYCO RAPID RESPONSE Series LFII Residential Concealed Pendent Sprin- klers (TY3596) must be installed in accordance with this section. General Instructions Damage to the fusible Link Assembly during installation can be avoided by handling the sprinkler by the support cup only (i.e., do not apply pressure to the fusible Link Assembly). A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maximum torque of 7 to 14 lbs-ft. (9,5 to 19,0 Nm). Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Cover Plate / Retainer Assembly by under- or over-tightening the Sprinkler. Read- just the position of the sprinkler fitting to suit. Step 1. The sprinkler must only be installed in the pendent position and with the centerline of the sprinkler per- pendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant applied to the pipe threads, and using the W-Type 18 Wrench shown in Figure 2, install and tighten the Sprinkler / Support Cup Assembly into the fitting. The W-Type 18 Wrench will accept a 1/2 inch ratchet drive. Step 4. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. The Protec- tive Cap helps prevent damage to the Deflector and Guide Pins during ceiling installation and/or during application of the finish coating of the ceiling. It may also be used to locate the center of the clearance hole by gently pushing the ceiling material against the center point of the Cap. Note: As long as the protective Cap remains in place, the system is consid- ered to be "Out Of Service." Step 5. After the ceiling has been completed with the 2-1/2 inch (63 mm) diameter clearance hole and in prep- aration for installing the Cover Plate Assembly, remove and discard the Pro- tective Cap, and verify that the Deflec- tor moves up and down freely. If the sprinkler has been damaged and the Deflector does not move up and down freely, replace the entire sprinkler assembly. Do not attempt to modify or repair a damaged sprinkler. Step 6. Screw on the Cover Plate Assembly until its flange comes in contact with the ceiling. Do not continue to screw on the Cover Plate Assembly such that it lifts a ceiling panel out of its normal position. If the Cover Plate Assembly cannot be engaged with the Mounting Cup or the Cover Plate Assembly cannot be engaged sufficiently to contact the ceiling, the Sprinkler Fitting must be repositioned. Care and Maintenance TYCO RAPID RESPONSE Series LFll Residential Concealed Pendent Sprin- klers (TY3596) must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system which it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. Absence of a Cover Plate may delay the sprinkler operation in a fire situation. When properly installed, there is a nominal 1/8 inch (3,2 mm) air gap between the lip of the Cover Plate and the ceiling, as shown in Figure 3. This air gap is necessary for proper opera- tion of the sprinkler by allowing heat flow from a fire to pass below and above the Cover Plate to help assure appropriate release of the Cover Plate in a fire situation. If the ceiling is to be repainted after the installation of the Sprinkler, care must be exercised to ensure that the new paint does not seal off any of the air gap. Factory painted Cover Plates must not be repainted. They should be replaced, if necessary, by factory painted units. Non-factory applied paint may adversely delay or prevent sprinkler operation in the event of a fire. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied or over heated sprinklers must be replaced. Care must be exercised to avoid damage before, during, and after instal- lation. Sprinklers damaged by drop- ping, striking, wrench twist/slippage, or the like, must be replaced. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national codes. TFP442 Page 6 of 6 I I Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assemblies Specify: Cover Plate Assembly with (specify) finish for the Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprinkler, P/N (specify): Ivory (RAL1 015) ...........P/N 56-202-0-135 Beige (RAL1 001)...........P/N 56-202-2-135 Pure White * (RAL9010) .....P/N 56-202-3-135 Signal White ** (RAL9003) ... P/N 56-202-4-135 Grey White (RAL9002) ......P/N 56-202-5-135 Brown (RAL8028)..........P/N 56-202-6-135 Black (RAL9005) ..........P/N 56-202-7-135 Brushed Brass ............P/N 56-202-8-135 Brushed Chrome ..........P/N 56-202-9-135 Custom Paint .............P/N 56-202-X-135 Eastern Hemisphere sales only Previously known as Bright White Note: All Custom Cover Plates are painted using Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Specify: W-Type 18 Sprinkler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. tqqxv TEFLON is trademark of The DuPont Corporation. Fire Protection Products -a7g§ 0 Fire Protection Products Worldwide Contacts I www.tyco-fire.com RAPID RESPONSE Series LFII Residential 4,9 K-factor Pendent Sprinkler Wet Pipe and Dry Pipe Systems General Description TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers (TY2234) are decorative, fast response, frangi- ble bulb sprinklers designed for use in residential occupancies such as homes, apartments, dormitories, and hotels. When aesthetics and optimized flow characteristics are the major con- sideration, the Series LFII Residential Sprinklers (1Y2234) should be the first choice. The Series LFII Residential Sprinklers are intended for use in the following scenarios: wet and dry pipe residential sprin- kler systems for one- and two-fam- ily dwellings and mobile homes per NFPA 13D wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 The recessed version of the Series LFII Residential Sprinklers is intended for use in areas with finished ceilings. It employs a two-piece Style 20 Recessed Escutcheon. The Recessed Escutcheon provides 1/4 inch (6,4 mm) of recessed adjustment or up to 1/2 inch (12,7 mm) of total adjustment from the flush ceiling position. The IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 adjustment provided by the Recessed Escutcheon reduces the accuracy to which the pipe drops to the sprinklers must be cut. The Series LFII Residential Sprinklers have been designed with heat sensi- tivity and water distribution charac- teristics proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application The Series LFII Residential Pendent and Recessed Pendent Sprinklers offers a laboratory approved option for designing dry pipe residential sprin- kler systems, whereas, most residential sprinklers are laboratory approved for wet systems only. Through extensive testing, it has been determined that the number of design sprinklers (hydraulic design area) for the Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) need not be increased over the number of design sprinklers (hydraulic design area) as specified for wet pipe sprinkler systems, as is accustomed for density/ area sprinkler systems designed per NFPA 13. Consequently, the Series LFII Resi- dential Sprinklers offer the features of non-water filled pipe in addition to not having to increase the number of design sprinklers (hydraulic design area) for systems designed to NFPA 13,13D, or 13R. NOTICE The Series LFII Residential Pendent and Recessed Pendent Sprinklers (TY2234) described herein must be installed and maintained in compliance with this document and the applicable standards of the National Fire Protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. MARCH 2015 Sprinkler Identification Number (SIN) TY2234 Technical Data Approvals UL Listed (for use with wet pipe and dry pipe sys- tems) C-UL Listed (for use only with wet pipe systems) Certified to all requirements of NSF/ANSI 61 (Refer to the Design Criteria section for de- tails on these approvals.) Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K=4.9 gpm/psi1/2 (70,6 pm/ban/2) Temperature Rating 155°F (68°C) or 175°F (79°C) Finishes Natural Brass, Pure White, Signal White, or Chrome Plated Physical Characteristics Frame ........................Brass Button ......................Copper Sealing Assembly ......Beryllium Nickel w/TEFLON Bulb (3 mm) ...................Glass Compression Screw ............Bronze Deflector .....................Bronze TFP400 TFP400 Page 2 of 6 7/16 (11,1 mm) 1/2 ESCUTCHEON Components: NOMINAL NPT PLATE SEATING 1 - Frame MAKE-IN SURFACE 2 - Button 3 - Sealing Assembly 1 4-Bulb 5 - Compression 2 Screw V~~ , 2-1/4 6 - Deflector* 3 (57,2 mm) 4 1-5/8' (41,3 mm) *Temperature H rating is 6* indicated on Deflector. CROSS SECTION PENDENT 2-7/8' DIA. (73,0 mm) WRENCH STYLE 20 FLATS ~W) RECESSED ESCUTCHEON RECESSED PENDENT FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) 2-7/8" DIA. (73,0 mm) 1/2" (12,7 mm) 2-1/4" DIA. 1/4" (6,4 mm) I (57,2 mm) MOUNTING , PLATE 1/8 (3,2 mm) 1-3/8' (34,9 mm)J 34 1-1/8" (28,6 mm) 7/16±1/8" (11,1±3,2 mm) FACE OF SPRINKLER FITTING T__\_ MOUNTING SURFACE CLOSURE Operation The glass bulb contains a fluid that expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and flow water. Design Criteria The TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers are UL and C-UL Listed for installation in accordance with this section. Residential Sprinkler Design Guide When conditions exist that are outside the scope of the provided criteria, refer to the Residential Sprinkler Design Guide TFP490 for the manufactur- er's recommendations that may be acceptable to the local authority having jurisdiction. / WRENCH RECESS / (END "A" USED FOR TY2234) FIGURE 3 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 4 W-TYPE 7 RECESSED SPRINKLER WRENCH System Types Per the UL Listing, wet pipe and dry pipe systems may be utilized. Per the C-UL Listing, only wet pipe systems may be utilized. Refer to Technical Data Sheet TFP485 for the use of residential sprinklers in residential dry pipe systems. Ceiling Types Smooth flat horizontal, or beamed, or sloped, in accordance with the 2013 Edition of NFPA 13D, 13R, or 13, as applicable. FIGURE 2 STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER TFP400 Page 3 of 6 Hydraulic Design (NFPA 13D and 13R) For systems designed to NFPA 13D or NFPA 13R, the minimum required sprinkler flow rates are given in Tables A and B as a function of tem- perature rating and the maximum allowable coverage areas. The sprinkler flow rate is the minimum required discharge from each of the total number of "design sprinklers" as specified in NFPA 130 or NFPA 13R. The number of "design sprinklers" specified in NFPA 13D and 13R for wet pipe systems is to be applied when designing dry pipe systems. Hydraulic Design (NFPA 13) For systems designed to NFPA 13, the number of design sprinklers is to be the four most hydraulically demanding sprinklers. The minimum required dis- charge from each of the four sprinklers is to be the greater of the following: The flow rates given in Table A or B as a function of temperature rating and the maximum allowable coverage area. A minimum discharge of 0.1 gpm/ft2 over the "design area" comprised of the four most hydraulically demanding sprinklers for actual coverage areas protected by the four sprinklers. The number of design sprinklers speci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry pipe systems. Dry Pipe System Water Delivery When using the Series LFII Residential Sprinklers (1Y2234) in dry pipe sprin- kler systems, the time for water deliv- ery must not exceed 15 seconds for the most remote operating sprinkler. Obstruction to Water Distribution Sprinklers are to be located in accor- dance with the obstruction rules of NFPA 13D, 13R, and 13 as applicable for residential sprinklers as well as with the obstruction criteria described within the Technical Data Sheet TFP490. Operational Sensitivity Sprinklers are to be installed with a deflector-to-ceiling distance of 1-1/4 to 4 inches. Sprinkler Spacing The minimum spacing between sprin- klers is 8 feet (2,4 m). The maximum spacing between sprinklers cannot exceed the length of the coverage area (Table A or B) being hydraulically cal- culated (e.g., maximum 12 feet for a 12 ft. x 12 ft. coverage area, or 20 feet for a 20 ft. x 20 ft. coverage area). Installation TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm). A leak-tight 1/2 inch NPT sprinkler joint should be obtained by applying a min- imum-to-maximum torque of 7 to 14 ft.-Ibs. (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in an Escutch- eon Plate by under- or over- tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Series LFII Residential Pendent Sprinklers The Series LFII Residential Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position with the deflector par- allel to the ceiling. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 3). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Series LFII Residential Recessed Pendent Sprinklers The Series LFII Residential Recessed Pendent Sprinklers must be installed in accordance with the following instructions: Step A. Install recessed pendent sprin- klers in the pendent position with the deflector parallel to the ceiling. Step B. After installing the Style 20 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 4). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Step D. After the ceiling has been installed or the finish coat has been applied, slide on the Style 20 Closure over the Series LFII Residential Sprin- kler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. TFP400 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure (2)(3) Maximum Coverage Ordinary Temperature Rating Intermediate Temperature Rating Area (1) 155°F (68°C) 175°F (79°C) Minimum Deflector to Installation Spacing Flow Pressure Flow Pressure Ft. x Ft. Ceiling Type Ft. (m x m) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4inches 14x14 13 7.0 13 7.0 (4,3 x 4,3) (49,2) (0,48) (49,2) (0,48) Beamed Recessed using Style 20 16 x 16 13 7.0 13 7.0 per Escutcheon or 8Ceilings (4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D or 13R non-recessed per NFPA 13D, 13R, or 13 (2,4) 18 x 18 17 12.0 17 12.0 (5,5 x 5,5) (64,3) (0,83) (64,3) (0,83) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 20 16.7 20 16.7 (6,1 x6,1) (75,7) (1,15) (75,7) (1,15) beam. Notes: I. For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpmlft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WET PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Maximum Minimum Flow and Residual Pressure (2)(3) Coverage Ordinary Temperature Rating Intermediate Temperature Rating Area (11 155°F (68°C) 175°F (79°C) Minimum Ft. x Ft. Deflector to Installation Spacing (mxm) Flow Pressure Flow Pressure Ceiling Type Ft. gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar) 12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings 1-1/4 to 4 14 X 14 (4,3 x 4,3) 14 (53,0) 8.2 (0,57) 14 (53,0) 8.2 (0,57) inches Beamed Recessed using Style 20 16x16 15 9.4 15 9.4 Ceilings Escutcheon or 8 (4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 13D or13R non-recessed perNFPA13D, 13R, or 13 (2,4) 18x18 18 13.5 18 13.5 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-1/4 to 1-3/4 inches below bottom of 20 x 20 21 18.4 21 18.4 (6,1 x 6,1) (79,5) (1,27) (79,5) (1,27) beam. Notes: For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design under the Design Criteria section. For NFPA 13 residential applications, the greater of 0.1 gpm/ft.2 over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234) NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA TFP400 Page 5 of 6 Care and Maintenance TYCO RAPID RESPONSE Series LFII Residential 4.9K Pendent and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section: Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (PIN). Sprinkler Assemblies Specify: Series LFll 4.9K Residential Pendent Sprinkler (1Y2234), (specify temperature rating), with (specify) finish, P/N (specify): 155°F (68°C) Natural Brass ..............P/N 51-201-1-155 Pure White (RAL 9010)*P/N 51-201-3-155 Signal White (RAL 9003) .....P/N 51-201-4-155 Chrome Plated .............P/N 51-201-9-155 175°F (79°C) Natural Brass ..............P/N 51-201-1-175 Pure White (RAL 9010)° ......P/N 51-201-3-175 Signal White (RAL 9003) .....P/N 51-201-4-175 Chrome Plated .............P/N 51-201-9-175 ° Eastern Hemisphere sales only Recessed Escutcheon Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770. Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 TFP400 Page 6 of 6 GLOBAL HEADQUARTERS 11400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700 Copyright © 2015 Tyco Fire Products, LP. All rights reserved. tqct TEFLON is trademark of the DuPont Corporation. Fire Protection Products LFCSD P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 510 CPVC — STEEL — COPPER HANGER 510 Fastener SIZE 3/4 2.125 1 2.312 1114 3.170 1112 3.400 2 4.010 21/2 4.320 3 1 5.320 SIZE - 3/4" thru 3" pipe. MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - 203 - EX 4231, EX 2551 FUNCTION - To support horizontal piping - CPVC, Copper or Steel. Hanger in listed mounting positions - Top, Bottom or Side. Also, provides stability on vertical piping. INSTALLATION - Per NFPA 13, 13R, 13D and CPVC manufacturers instructions, mount on top, bottom or side of building element. Space by pipe type. FASTENERS - UL Listed per NFPA 13 in WOOD: 3/4" - 3" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. 3/4" - 2" Steel pipe - 1/4"xl 1/2' lag screw - no pre-drill. in STEEL - mm. 18 GA. 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. *CAN ALSO BE USED TO REPLACE — #500 Pipe Strap #520 Tin Strap Specific AFCON product are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, elate used. 9/11 5— ] P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 511 CPVC — COPPER SIDE MOUNT HANGER Side View - For Drawings Below SIZE - SYSTEM PIPE: 3/4" thru 2" MATERIAL - Carbon Steel. FINISH - Mil. Galvanized. LISTING/APPROVAL - 12"' 203 - EX 4231, EX 2551 FUNCTION - Support horizontal piping - CPVC or Copper. Stabilize vertical piping. INSTALLATION - Per these instructions including NFPA 13, 13R, 13D and CPVC manufacturers instructions. Install on vertical mounting surface. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. in STEEL - mm. 18 GA. 3/4" - 2" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Copper pipe - 1/4" or #14 Tek Screw. FEATURES * Offset edge eliminates abrasion. * Retainer dimples secure hanger to pipe during installation. * Required AFCON #905 screw included - 5/16" hex head. ORDERING - Part # and pipe size. Hanger - Wood Stud Hanger- Metal Stud Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER- AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by .4FCON. AFCON shall NOT be liable under any circumstances whatsoever for any director indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCON products have been, or accused. . 9/08 P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 513 CPVC - STEEL - COPPER HANGER I SIZE 3/4' thru 2" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - cas 203 - EX 4231, EX 2551 FUNCTION - To support horizontal piping - CPVC, Copper or Steel. Tab up = Hanger. INSTALLATION - Per NFPA 13,13R and 13D on side or top of beam. Space by pipe type. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13. in WOOD: 3/4" - 2" CPVC pipe - #905 screw - no pre-drill. 3/4" - 2" Copper pipe - #905 screw - no pre-drill. 3/4" - 2" Steel pipe - 1/4"xi 1/2" lag screw - no pre-drill. FEATURES * Offset edge eliminates abrasion. * Required AFCON #905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCONproducts including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non-AFCONproducts have been, or are used. 2/08 JA P.O. Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 514 st00 0:906 1.5000— OFFSET CPVC HANGER SIZE - 3/4" thrill 3"pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized.. LISTING/APPROVAL - clXrs 203 - EX 4231, EX 2551 PATENT - No. 6,648,278. FUNCTION - 3/4"-2" Hanger/restrainer for horizontal CPVC, Copper or Steel pipe. Listed hanger/restrainer in all 3 mounting positions, i.e. vertical surface and both top and bottom of horizontal surface. Provides listed vertical/lateral restraint and prevents upward movement of pipe that supplies a pendent sprinkler below a ceiling. Size 2 1/2I Hanger for horizontal CPVC pipe. Listed hanger in all 3 mounting positions. i.e. vertical surface and both top and bottom of horizontal surface. Size 3" Hanger for horizontal CPVC pipe in two mounting positions, side and bottom. i.e. vertical surface and bottom of horizontal surface. Stabilizes vertical piping by providing horizontal restraint. INSTALLATION - Per NFPA 13,13R and 13D. Space by pipe type. Install on wood, concrete or steel - See Drawings. Snap over pipe then squeeze strap back allowing pipe to slide freely. Listed When #905 threads are exposed in wood, install #906 backing nut. 3/4' SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13 WOOD - 3/4" - 3" CPVC pipe - #905 screw- no pre-drill. 3/4" - 2" Copper pipe - #905 screw- no pre-drill. 3/4" - 2" Steel pipe - 1/4"xl 1/2" lag screw - no pre-drill. Thrill 5/8" gypsum board - 1/4" x 2" lag screw. STEEL - mm. 18 GA. - 3/4" - 3" CPVC pipe - 1/4" or #14 Tek Screw. 3/4" -2" Copper pipe - 1/4" or #14 Tek Screw. 3/4" - 2" Steel pipe - 1/4" or #14 Tek Screw. CONCRETE: Required minimum load each fastener = 5(wt)+2501bs. 2 FEATURES * 1 1/2" Offset - loose fit allows pipe to slide. * 3/4" and 1" pipe size made with common center-line. * Patented design for superior strength. * Offset edge eliminates abrasion. * AFCON#905 screw has 5/16" hex head - included. ORDERING - Part # and pipe size. AFCON #906 backing nut sold separately. 4 I 0 Listed Restraint 3/4 thru 2" Specific AFCON products are exclusively designed to be compatible ONLY with other .4FCON products including parts and fasteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER. .4FCONwitl NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, when non.AFCON products have been, or are used, 6/08 1.00 T[ IAcsn P.O. Box 3365 South 8 Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 515 DOUBLE OFFSET CPVC HANGER • SIZE - 3/4" and 1" pipe. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTING/APPROVAL - 203 - EX 4231 PATENT - No. 6,702,236 FUNCTION - Hanger/restrainer for horizontal CPVC pipe. INSTALLATION - Per NPFA 13,13R and 13D. SPECIAL NOTE: When installing on CPVC sprinkler system pipe: Verify that all assembly components are cleaned of any surface oil. FASTENERS - UL Listed per NFPA 13. WOOD: 3/4" and 1" #904 screw - no pre-drill. FEATURES * Double 1 1/2" offset - loose fit allows pipe to slide. * Center line matches AFCON #514. * 3/4" and 1" pipe size have common center-line. * Offset edge eliminates abrasion. * Required AFCON #904 screw has 3/8" hex head - included. ORDERING - Part # and pipe size. Specific AFCON products are exclusively designed to be compatible ONLY with other AFCON products including parts and ibsteners, resulting in a listed sway brace, restrainer or hanger assembly. Be advised the following warranty restriction will apply. DISCLAIMER - AFCON will NOT warrant against the failure of its products when used in combination with other products, parts or systems not manufactured or sold by AFCON. AFCON shall NOT be liable under any circumstances whatsoever for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or neofit. when non.AFCONnrnducls have been, or are used. Installation Pictures 2/08