HomeMy WebLinkAbout5345 ARMADA DR; ; FPC2019-0217; PermitPER(XT REPORT (City of Carlsbad Print Date: 08/30/2022 Permit No: FPC2019-0217 Job Address: 5345 ARMADA DR, CARLSBAD, CA 92008-4602 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2110231700 Track #: Applied: 09/16/2019 Valuation: $449,658.68 Lot #: Issued: 10/03/2019 Occupancy Group: Project 4*: Finaled Close Out: 03/09/2021 #of Dwelling Units: Plan 4*: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 4*: INSPECTOR: Salcedo, Felix Plan Check 4*: Project Title: Description: GIA -FIRE SPRINKLER TI (75 HEADS) Applicant: FPContractor: MARCUS ENGLISH JOHNSON CONTROLS FIRE PROTECTION LP 3568 RUFFIN RD P0 BOX 3042 - SAN DIEGO, CA 92123-2597 BOCA RATON, FL 33431-0942 (858) 633-9125 (561) 341-7780 FEE AMOUNT FIRE NFPA 13 or 13R System 7 - 100 heads $553.00 Total Fees: $553.00 Total Payments To Date: $553.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov I .. Prczoft.owl. tqC00 Worldwide I www.tyco-fire.com Contacts Series TY-FRB, 56 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description The TYCO Series TY-FRB, 5.6 K-factor, Upright (1Y313) and Pendent (1Y323) Sprinklers described in this data sheet are quick response, standard coverage, decorative 3 mm glass bulb-type spray sprinklers designed for use in light or ordinary hazard, commercial occupan- cies such as banks, hotels, and shop- ping malls. The recessed version of the Series TY-FRB Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. This recessed pendent sprinkler uses one of the following: A two-piece Style 15 Recessed Escutcheon with recessed adjust- ment up to 5/8 in. (15,9 mm) from the flush pendent position. A two-piece Style 20 Recessed Escutcheon with recessed adjust- ment up to 1/2 in. (12,7 mm) from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Intermediate level versions of Series TY-FRB Sprinklers are described in Technical Data Sheet TFP357. Sprin- kler guards and shields are described in Technical Data Sheet TFP780. IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Page 1 of 4 FITIMM The TYCO Series TY-FRB Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY313.... Upright 5.6K, 1/2 in. NPT TY323 .... Pendent 5.6K, 1/2 in. NPT Technical Data Approvals Refer to Table A Maximum Working Pressure 175 psi (12.1 bar) 250 psi (17.2 bar)* The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato- ries. Inc. (UL). Discharge Coefficient K=5.6 GPM/psi/2 (80,6 LPM/bar½) Temperature Rating Refer to Table A Finishes Sprinkler: Refer to Table B Recessed Escutcheon: White Coated, Black Coated, Chrome Plated, or Brass Plated Physical Characteristics Frame ............................Bronze Button ......................Brass/Copper Sealing Assembly . . . Stainless Steel w/TEFLON Bulb ............................... Glass Compression Screw .................Bronze Deflector ..........................Bronze AUGUST 2018 Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCOSeries TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (such as, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of FM's Loss Prevention Data Sheets). Only the Style 15 or Style 20 Recessed Escutcheon is to be used for recessed pendent installations. TFPI72 .- - .'t, L\• s',' TFPI72 • Page 2 of 4 Components: * Temperature rating is ** Pipe thread connections per ISO 7-1 1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. 2 - Button 5 - Compression STYLE 15 or 20 3 - Sealing Screw ESCUTCHEON PLATE 1/2 7/16 (11,1 mm) RECESSED Assembly 6 - Deflector* DEFLECTOR * SEATING SURFACE NPT** NOMINAL MAKE-IN ESCUTCHEON 6* 5 1 7/16 : I (11,1 mm) WP 4 _____ I NOM MAKE-IN NOMINAL (50, mm) 2" ______ (50,8 mm) _______ \,j Fl 1/2' NPT** DEFLECTOR* [- 2-7/8' (73,0 mm) DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT FIGURE 1 SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE Installation The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be installed in accor- dance with this section. General Instructions Do not install any bulb-type sprin- kler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diam- eter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) and 3/32 in. (2,4 mm) for the 286°F (141°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by applying a minimum to maximum torque of 7 to 14 lb-ft (9,5 to 19,0 Nm). Higher levels of torque can distort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the Escutch- eon Plate by under- or over-tightening the sprinkler. Re-adjust the position of the sprinkler fitting to suit. Upright and Pendent Sprinklers The Series TY-FRB Upright and Pendent Sprinklers must be installed in accordance with the following instructions. Step 1. Install Pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe-thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Figure 2). With ref- erence to Figure 1, apply the W-Type 6 Sprinkler Wrench to the wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm). Recessed Pendent Sprinklers The Series TY-FRB Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions. Step A. After installing the Style 15 or Style 20 Mounting Plate over the sprinkler threads, and with pipe-thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Figure 3). With reference to Figure 1, apply the W-Type 7 Recessed Sprinkler Wrench to the sprinkler wrench flats. Torque sprinklers 7 to 14 lb-ft (9,5 to 19,0 N.m). Step C. After ceiling installation and finishing, slide on the Style 15 or Style 20 Closure over the Series TY-FRB Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. WRENCHSS S FIGURE 2 W-TYPE 6 SPRINKLER WRENCH WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 3 W-TYPE 7 RECESSED SPRINKLER WRENCH / TFPI72 Page 3 of 4 le Care and Maintenance The TYCO Series TY-FRB, 5.6 K-factor, Upright (TY313) and Pendent (TY323) Sprinklers must be maintained and ser- viced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection systems from the proper authorities and notify all personnel who may be affected by this action. Absence of the outer piece of an escutcheon, which is used to cover a clearance hole, can delay sprinkler operation in a fire situation. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installa- tion Section.) The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler systems are rec- ommended to be inspected, tested, and maintained by a qualified Inspec- tion Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-FRB Upright or Pendent (specify) Sprinkler, SIN (specify), K=5.6, Quick Response, (specify) temperature rating, (specify) finish, P/N (specify, refer to Table A). Recessed Escutcheon Specify: Style 15 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Specify: Style 20 Recessed Escutch- eon with (specify*) finish, P/N (specify*) Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 - 2-7/8 DIA. (73,0 mm) - 2-1/4 DIA. FACE OF (57,2 mm) SPRINKLER 5/8 (15,9 mm) FITTING FLUSH 3/8±5/16" (9,5±7,9 mm) 7 I /K 1/8" SURFACE J MOUNTING (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm) TYFRB PLATE 3/4" (19,1 mm) FIGURE 4 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15 RECESSED ESCUTCHEON 2-7/8 DIA. (73,0 mm) FACE OF SPRINKLER - 2-1/4 DIA. FITTING (57,2 mm) 5/16±1/4 / \ 1/2(12,7mm) (7,9±6,4 mm) I I—i FLUSH MOUNTING J I SURFACE /1 \ (3,2 mm) CLOSURE SERIES MOUNTING 1-3/8" (34,9 mm) TY-FRB PLATE 7/8" (22,2 mm) FIGURE 5 SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323) WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20 RECESSED ESCUTCHEON SIN 370 5.6K UPRIGHT (1/2 in.NPT) 1Y313 371 5.6K PENDENT (1/2 in.NPT) TY323 Notes: a. Use suffix '1" for ISO 7-1 connection; for example, 77-370-4-175-I TFPI72 (. Page 4 of 4 SPRINKLER FINISH (See Note 7) K FACTOR TYPE TEMPERATURE BULB LIQUID COLOR NATURAL BRASS I CHROME j PLATED 1POLYESTERr 135°F (57°C) Orange UPRIGHT (TY313) and 1, 2, 3, 4, 5, 6 155°F (68°C) Red 175°F (79°C) Yellow 5.6 1/2 in. NPT PENDENT (TY323) 200°F (93°C) Green 286°F (141°C) Blue ________________ 135°F (57°C) Orange RECESSED PENDENT (TY323) Figures 4a and 5b 1,2,3,4 155°F (68°C) Red 175°F (79°C) Yellow 200°F (93°C) Green Notes: Listed by Underwriters Laboratories, Inc., (UL) as Quick Response Sprinklers. Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL) as Quick Response Sprinklers. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. Approved by the City of New York under MEA 354-01-E. VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.) Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. Installed with Style 15(1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable. Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable. C. Frame and Deflector only. Listings and approvals apply to color (Special Order). TABLE A LABORATORY LISTINGS AND APPROVALS FOR 5.6 K-FACTOR SPRINKLERS SPRINKLER TEMPERATURE I FINISH RATINGS 1 NATURAL BRASS 135 135°F (57°C) PURE WHITE (RAL9010)a 155 155°F (68°C) POLYESTER SIGNAL WHITE (RAL9003) 175 175° F (79°C) POLYESTER JET BLACK (RAL9005) 200 200°F (93°C) POLYESTER 9 CHROME PLATED 286 286°F (141°C) Notes: a. Eastern Hemisphere sales only TABLE B SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION 1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215.362-0700 A)VII C2Ol8Johnoon Controls. All rights reserved. All specificatIons and other Information shown wore curentas ofdocument revision dote and are sublectto change wIthout Casio.. 'Johnson NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trodnv,a,kn at NatlCnel Fire Protection A000cietlon; Controls TEFLON is a ,sQlste,ed vsden,a,k of DuPont