Loading...
HomeMy WebLinkAbout5796 ARMADA DR; 200; AS110182; PermitCity of Carlsbad Sprinkler Permit Job Address: 5796 ARMADA DR 2.c0 Permit Type: SPRINK Parcel No: 2111000400 Lot #: 0 Reference No.: Status: APPROVED Applied 12/15/2011 Approved: 12/29/2011 Issued: 12/29/2011 PC #: Inspector: Project Title: MORGAN STANLEY CARLSBAD EXP T.I. Applicant: A & D FIRE SPRINKLERS, INC. 2ND FLOOR 11465 WOODSIDE AVE SANTEE, CA 92071 619-448-1962 Owner: OCEAN RIDGE OFFICE CORP C/O LASALLE INVESTMENT MGMT 200 E RANDOLPH ST #4400 CHICAGO IL Fees Total TF alance I LFees ±LE Add'I FlEE SERINKLERE: INC. MORGAN STANLEY CARLSBAD EXPANSION 5796 ARMADA DRIVE SUITE 200 CARLSBAD, CA 92008 FIRE SPRINKLER SUBMITTALS MANUFACTURER DATA SHEETS ** Materials of equal design, utility, and performance may be substituted for submitted materials so as to avoid delays in the construction schedule and shall be deemed accepted by the Purchaser. S tJJCU Fire Suppression & Building Products Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Email: techserv@tycofp.com Series RFII - 56 K-factor "Royal Flush II" Concealed Pendent Sprinklers Quick & Standard Response, Standard Coverage S [1 General Description The Tyco® Series RFll Quick Response (3-mm bulb) and Standard Response (5-mm bulb), 5.6 K-Factor, 'Royal Flush II" Concealed Pendent Sprin- klers are decorative sprinklers featur- ing a flat cover plate designed to con- ceal the sprinkler. These sprinklers are optimal for architecturally sensitive ar- eas such as hotel lobbies, office build- ings, churches, and restaurants. Each sprinkler includes a Cover Plate! Retainer Assembly and a Sprinkler! Support Cup Assembly. The separa- ble, two-piece assembly design pro- vides the following benefits: Allows installation of the sprinklers and pressure testing of the fire pro- tection system prior to installation of a suspended ceiling or applica- tion of the finish coating to a fixed ceiling. Permits the removal of suspended ceiling panels for access to building service equipment without having to first shut down the fire protection system and remove sprinklers. Provides for 1/2 inch (12,7 mm) of vertical adjustment to allow a mea- sure of flexibility in determining the length of fixed piping to cut for the sprinkler drops. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a tire situation or cause it to operate prematurely. The Series RFII Sprinklers are shipped with a Disposable Protective Cap. The Protective Cap is temporarily removed during installation and replaced to help protect the sprinkler during ceiling in- stallation or finish. The tip of the Pro- tective Cap can be used to mark the center of the ceiling hole into plaster board or ceiling tiles by gently push- ing the ceiling product against the Pro- tective Cap. When ceiling installation is complete, the Protective Cap is re- moved and the Cover Plate/Retainer Assembly is installed. As an option, the Series RFII Standard Response (5-mm bulb) "Royal Flush II" Concealed Pendent Sprinklers can be fitted with a silicone Air and Dust Seal. (Refer to Figure 5.) The Air and Dust Seal is intended for sensitive areas where it is desirable to prevent air and dust from the area above the ceiling to pass through the cover plate. (I)tDI The Series RFII Concealed Pendent Sprinklers described herein must be installed and maintained in compliance with this document and with the appli- cable standards of the National Fire Protection Association, in addition to the standards of any authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Sprinkler Identification Number (SIN) TY3531 - 3 mm bulb TY3551 - 5 mm bulb Page 1 of 6 OCTOBER 2009 TFPI8I TFPISI Page 2 of 6 1/2 NPT SEALING ASSEMBLY FRAME CAP SUPPORT CUP WITH BULB ROLL FORMED I THREADS COMPRESSION __- - SCREW GUIDE— PINS (2) DEFLECTOR (DROPPED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP I ASSEMBLY THREAD INTO H RETAINER SUPPORT CUP f WITH THREAD UNTIL MOUNTING r- DIMPLES SURFACE IS FLUSH WITH EJECTION CEILING SPRING SOLDER COVER TABS (3) COVER PLATE/RETAINER PLATE ASSEMBLY FIGURE 1 MODEL RFII CONCEALED SPRINKLER ASSEMBLY Technical Data Sprinkler Approvals Approvals apply only to the service conditions indicated in the Design Cri- teria section. 1Y3531 (3-mm Bulb) is UL Listed, C-UL Listed, LPCB Approved (Ref. No. 094a/10), VdS Approved (Cer- tificate No. G 4090007), and NYC Approved (MEA 353-01-E) as Quick Response. 1Y3531 (3-mm Bulb) is FM Ap- proved as Standard Response. Factory Mutual does not approve any concealed sprinklers for quick response. 1Y3551 (5-mm Bulb) is UL Listed, C-UL Listed, FM Approved, LPCB Approved (Ref. No. 094a19), and NYC Approved (MEA 353-01-E) as Standard Response. Approvals for Air and Dust Seal UL and C-UL Listed for use with the RFII Standard Response Concealed Sprinkler (TY3551). Maximum Working Pressure Maximum 250 psi (17,3 bar) by UL, C-UL, and NYC Maximum 175 psi (12,1 bar) by FM, VdS, and LPCB Temperature Rating 155°F/68°C Sprinkler with 139°F/59°C Plate 200°F/93°C Sprinkler with 1 65°F/74°C Plate Discharge Coefficient K= 5.6 GPM/psi112 (80,6 LPM/bar112) Adjustment 1/2 inch (12,7 mm) Finishes See the Ordering Procedure section. Physical Characteristics Frame ...................Bronze Support Cup... Chrome Plated Steel Guide Pins .........Stainless Steel Deflector ....... . ......... Bronze Compression Screw.........Brass Bulb ......................Glass Cap.............Bronze or Copper Sealing Assembly.........Beryllium Nickel w/ Teflont Cover Plate................Brass Retainer ..................Brass Ejection Spring......Stainless Steel tDuPont Registered Trademark Design Criteria The Tyco® Series RFll Concealed Pen- dent Sprinklers are intended for fire protection systems designed in ac- cordance with the standard instal- lation rules recognized by the appli- cable Listing or Approval agency; for example, UL Listing is based on NFPA 13 and VdS Approval is based on the CEA 4001. For more information on LPCB and VdS Approvals, contact Tyco Fire Sup- pression & Building Products at the following office: Enschede, Netherlands Telephone: 31-53-428-4444 Fax: 31-53-428-3377 The Series RFll Concealed Pendent Sprinklers are only listed and approved with the Series RFII Concealed Cover Plates having a factory applied finish. L'1.1IDl Do not use the Series RF!1 in applica- tions where the air pressure above the ceiling is greater than that below. Down drafts through the Sprinkler/Support Cup Assembly can delay sprinkler op- eration in a fire situation. CLEARANCE HOLE TFPI8I Page 3 of 6 FACE OF CLEARANCE HOLE SPRINKLER DIAMETER FITTING SPRINKLER SUPPORT CUP ASSEMBLY - N 1/2 (12,7 mm) DIMENSION THREADED D ADJUSTMENT I FACE OF CEILING, I RETAINING RING I MOUNTING I SURFACE 777J T- ~- \ H -\- T ------ T 3/16 to 11/16 MANUFACTURER DEFLECTOR COVER PLATE (4,8 to 17,5 mm) PRESET GAP IN DROPPED RETAINER REFERENCE 3/32' (2,4 mm) POSITION ASSEMBLY COVER PLATE COVER PLATE - PROFILE DEPTH DIAMETER DIMENSION B DIMENSION A 3-1/4 inches (82,6 mm) C: 2-3/8 to 2-5/8 inches (60,3 to 66,7 mm) 3/16 inches (4,8 mm) D: 1-3/4 to 2-1/4 inches (44,5 to 57,2 mm) FIGURE 2 SERIES CONCEALED SPRINKLER INSTALLATION DIMENSIONS Operation When exposed to heat from a fire, the Cover Plate, normally soldered to the Retainer at three points, falls away to expose the Sprinkler/Support Cup Assembly. The Deflector—supported by the Guide Pins—then drops down to its operational position. The glass Bulb contains a fluid that ex- pands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass Bulb, activating the sprinkler and allowing water to flow. FIGURE 4 DISPOSABLE PROTECTIVE CAP 0 TFPI8I Page 4 of 6 Installation The Tyco® Series RFII must be in- stalled in accordance with the follow- ing instructions. i.iiiw Do not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bub- ble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 155°17/680C and 3/32 inch (2,4 mm) for the 200°F/93°C temperature ratings. Obtain a 1/2 inch NPT sprinkler joint by applying a minimum to maximum torque of 7 to 14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels of torque can dis- tort the sprinkler Inlet with consequent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in the Sprinkler by under- or over-tightening the Sprin- kler/Support Cup Assembly. Re-adjust the position of the sprinkler fitting to suit. Step 1. Install the sprinkler only in the pendent position with the center-line of the sprinkler perpendicular to the mounting surface. Step 2. Remove the Protective Cap. Step 3. With pipe thread sealant ap- plied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 4. Wrench-tighten the sprinkler using only the RFII Sprinkler Wrench. (Refer to Figure 3.) Apply the RFll Sprinkler Wrench to the Sprinkler as shown in Figure 3. Step 5. Replace the Protective Cap by pushing it upwards until it bottoms out against the Support Cup. (Refer to Figure 4.) The Protective Cap helps prevent damage to the Deflector and Arms during ceiling installation and/or finish. You can also use the Protective Cap to locate the center of the clear- ance hole by gently pushing the ceiling material up against the center point of the Protective Cap. A'LhIILh1 As long as the Protective Cap remains in place, the system is considered "Out of Service". Step 6. After the ceiling has been com- pleted with the 2-1/2 inch (63,5 mm) diameter clearance hole and in prepa- ration for installing the Cover Plate/Re- tainer Assembly, remove and discard the Protective Cap. Verify that the De- flector moves up and down freely. If the Sprinkler is damaged and the Deflector does not move up and down freely, replace the entire Sprinkler. Do not attempt to modify or repair a damaged sprinkler. Step 7. When installing an Air and Dust Seal, refer to Figure 5; otherwise, pro- ceed to Step 8. To attach the Air and Dust Seal, verify the angle of the out- side edge of the seal is oriented ac- cording to Figure 5. Start the edge of the Retainer in the grooved slot of the Air and Dust Seal and continue around the retainer until the entire Air and Dust Seal is engaged. Step 8. Screw on the Cover Plate/ Retainer Assembly until the Retainer (shown in Figure 2) or the Air and Dust Seal (shown in Figure 5) contacts the ceiling. Do not continue to screw on the Cover Plate/Retainer Assembly so that it lifts a ceiling panel out of its normal position. If you cannot engage the Cover Plate/Retainer Assembly with the Support Cup or you cannot engage the Cover Plate/Retainer As- sembly sufficiently to contact the ceil- ing, you must reposition the Sprinkler Fitting. Care and Maintenance The Tyco® Series RFII must be maintained and serviced in accordance with the following instructions. Before closing a fire protection sys- tem main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection sys- tem from the proper authorities and no- tify all personnel who may be affected by this action. Absence of the Cover Plate/Retainer Assembly can delay sprinkler opera- tion in a fire situation. When properly installed, there is a nominal 3/32 inch (2,4 mm) air gap be- tween the lip of the Cover Plate and the ceiling, as shown in Figure 2. This air gap is necessary for proper operation of the sprinkler. If the ceil- ing requires repainting after sprinkler installation, ensure that the new paint does not seal off any of the air gap. Do not pull the Cover Plate relative to the Enclosure. Separation may result. Replace sprinklers that: are leaking or exhibiting visible signs of corrosion. were modified or over-heated. Never paint, plate, coat, or otherwise alter automatic sprinklers after they leave the factory. Never repaint facto- ry-painted Cover Plates. If necessary, replace them with factory-painted units. Non-factory applied paint can adversely delay or prevent sprinkler operation in the event of a fire. Exercise care to avoid damage to sprinklers before, during, and after in- stallation. Replace sprinklers damaged by dropping, striking, wrench twisting, wrench slipping, or the like. Also, re- place any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Refer to the Installation section.) If you must remove a sprinkler, do not reinstall it or a replacement without re- installing the Cover Plate/Retainer As- sembly. If a Cover Plate/Retainer As- sembly becomes dislodged during service, replace it immediately. Responsibility lies with sprinkler own- ers for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the ap- plicable standards of the National Fire Protection Association (for example, NFPA 25), in addition to the standards of any other authorities having jurisdic- tion. Contact the installing contractor or sprinkler manufacturer regarding any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accor- dance with local requirements and/or national code. SUPPORT SPRINKLER FACE OF ORIENT CEILING SEAL BEVEL AS SHOWN COVER ASSEMBLY SUPPORT PLATE RETAINER CLEAN ROOM LIP OF COVER SEAL RETAINER PLATE FIGURE 5 OPTIONAL AIR AND DUST SEAL FOR SERIES RFII (TV3551) TFPI8I Page 5 of 6 Limited Warranty Products manufactured by Tyco Fire Suppression & Building Products (TFSBP) are warranted solely to the original Buyer for ten (10) years against defects in material and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFSBP. No warranty is given for prod- ucts or components manufactured by companies not affiliated by ownership with TFSBP or for products and com- ponents which have been subject to misuse, improper installation, corro- sion, or which have not been installed, maintained, modified or repaired in ac- cordance with applicable Standards of the National Fire Protection Associa- tion, and/or the standards of any other Authorities Having Jurisdiction. Mate- rials found by TFSBP to be defective shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of prod- ucts or parts of products. TFSBP shall not be responsible for sprinkler system design errors or inaccurate or incom- plete information supplied by Buyer or Buyer's representatives. In no event shall TFSBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFSBP was informed about the possibility of such damages, and in no event shall TFSBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties, ex- press or implied, including warranties of merchantability and fitness for a particular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name. Sprinkler/Support Cup Assembly Specify: (SIN), (temperature rating from below) Series RFll Concealed Pendent Sprinkler, P/N (specify). 155°F/68°C 200°F/93C TY3531 51-792-1-155 51-792-1-200 TY3551 51-790-1-155 51-790-1-200 Separately Ordered Cover Plate/ Retainer Assembly: Specify: (temperature rating from be- low) Series RFII Concealed Cover Plate with (finish), P/N (specify). 139°F/59°C(a) 165°F/74°C(b) Brass..........56-792-1-135 56-792-1-165 Chrome........56-792-9-135 56-792-9-165 Signal White (RAL 9003).... 56-792-4-135 56-792-4-165 Grey White (RAL 9002).... 56-792-0-135 56-792-0-165 Pure White (c) (RAL 9010). ... 56-792-3-135 56-792-3-165 Custom ........56-792-X-135 56-792-X-165 For use with 155F/68C sprinklers. For use with 200F/93°C sprinklers. Eastern Hemisphere sales only. Sprinkler Wrench Specify: RFll Sprinkler Wrench, P/N 56-000-1-075. Air and Dust Seal Specify: Air and Dust Seal, P/N 56-908-1-001. 11 TFPI8I Page 6 of 6 © 2008 - 2009 TYCO FIRE SUPPRESSION & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446