HomeMy WebLinkAbout5796 ARMADA DR; 375; FA120057; PermitCity of Carlsbad Fire Alarm Permit Permit No: FA120057 Job Address: 5796 ARMADA DR Permit Type: FALARM Parcel No: 2111000400 Lot #: 0 Reference No.: PC #: Project Title: MACQUARIE T.I. Status: PENDING Applied 12/12/2012 Approved: Issued: Inspector: Applicant: GLENDALE FIRE SYSTEMS 6657 SAN FERNANDO RD GLENDALE, CA 818-244-3473 Owner: OCEAN RIDGE OFFICE CORP C/O LASALLE INVESTMENT MGMT 200 E RANDOLPH ST #4400 CHICAGO IL Fees ($) Add'I Fees ($) Total ($) Balance ($) 286 0 286 0 CALIFORNIA STATE FIRE MARSHALL LISTNGS GLENDALE FIRE SYSTEMS INC. 6657 SAN FERNANDO ROAD GLEDALE CA 91201 PONE: (818)244-3473 FAX: (818)246-9154 C-10 LICENCE# 757476 U.L.LISTING# S7307 MAC QUARIE 5796 ARMADA DR. CARLSBAD, CA 92008 FA O2 (DOS 7 MEA GSA-MCR 4 GILA iv T TM Fire & Life Safety Intelligent Input/Output Control.Relay Modules GSA-CR, GSA-MCR, GSA-CRR, GSA-MCRR Overview The Control Relay Module and the Polarity Reversal Relay Module are part of the Signature Series system. They are intelligent analog addressable devices available in either plug-in (UIO) versions, or standard 1-gang mount versions. The GSA-CRJMCR Control Relay Module provides a Form "C" dry relay contact to control external appliances such as door cbs ers, fans, dampers etc. This device does not provide supervision of the state of the relay contact. Instead, the on-board micro- processor ensures that the relay is in the proper ON/OFF state. Upon command from the loop controller, the GSA-CR/MCR relay activates the normally open or normally-closed contact. The GSA-CRR/MCRR Polarity Reversal Relay Module provides a Form "C" dry relay contact to power and activate a series of GSA-AB4G Audible Sounder Bases. Upon command from the Signature loop controller, the GSA-CAR reverses the polarity of its 24 Vdc output, thus activating all Sounder Bases on the data loop Standard-mount versions (GSA-CR and GSA-CRR) are installed to standard North American 1-gang electrical boxes, making them ideal for locations where only one module is re- quired. Separate I/O and data loop connections are made to each module. Plug-in UIO versions (GSA-MCR and GSA-MCRR) are part of the UIO family of plug-in Signature Series modules. They function identically to the standard mount versions, but take advantage of the modular flexibility and easy installation that characterizes all UIO modules. Two- and six-module UIO motherboards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Edwards enclosures. Standard Features Provides one no/nc contact (GSA-CR/MCR) Form "C" dry relay contact can be used to control external ap- pliances such as door closers, fans, dampers etc. Allows group operation of sounder bases The GSA-CRR/MCRR reverses the polarity of its 24 Vdc out- put, thus activating all Sounder Bases on the data loop. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote locations that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties; twisted or shielded wire is not required. Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 6 DATA SHEET M85001-0239 Not to be ud for iristallntion perposes. Issue 7.4 Installation GSA-CR and GSA-CRR: modules mount to North American 21/2 inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Compatible electrical box Wall plate, white a S. (1-gang) S.. is LEDs LED viewing ports a S. GSA-MCR and GSA-MCRR: mount the UIO motherboard inside a suitable Edwards enclosure with screws and washers provided. Plug the module into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UlO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. UlO Motherboard 6-32 Self-tapping screws Plug- Module screws #6 Flat washers -Cabinet or electrical enclosure Application The operation of Signature Series control relays is determined by their sub-type code or "Personality Code." Personality Code 8: CONTROL RELAY (GSA-CR/MCR) - Dry Contact Output. This setting configures the module to provide one Form C" DRY RELAY CONTACT to control Door Closers, Fans, Dampers, etc. Contact rating is 2.0 amp @ 24 Vdc; 0.5 amp @ 120 Vac (or 0.25A @ 220 Vac for non-UL applications). Personality Code 8 is assigned at the factory. No user configura- tion is required. Personality Code 8: POLARITY REVERSAL RELAY MODULE (GSA-CRR/MCRR). This setting configures the module to reverse the polarity of its 24 Vdc output. Contact rating is 2.0 amp @ 24 Vdc (pilot duty). Personality Code 8 is assigned at the factory. No user configuration is required. Compatibility The Signature Series modules are compatible only with Vigilant's Signature Loop Controller. Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Testing & Maintenance The module's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message. The user-friendly maintenance program shows the current state of each module and other per- tinent messages. Single modules may be turned off (deactivated) temporarily, from the control panel. Availability of maintenance features is dependent on the fire alarm system used. Scheduled maintenance (Regular or Selected) for proper system operation should be planned to meet the requirements of the Authority Hav- ing Jurisdiction (AHJ). Refer to current NFPA 72 and ULC CAN/ ULC 536 standards. Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on- bbard memory. The loop controller identifies each device on the loop and assigns a 'soft" address to each serial number. If desired, the modules can be addressed using the SIGA-PRO Signature Program/Service Tool. Edwards recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Page 2of6 DATA SHEET M850010239 - Not to be used floi 61stallation purposes. Issue 7.4 DATA IN (+) 1. DATA IN(-) From Signature or Previous Green LED (Normal) AOUT(+) AOUT(-) Ject Device GSA-CR Control Relay Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), #14 AWG (1.50mm2) and #12 AWG (2.5mm2) wire sizes. Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Normally- Normally- Open Common Closed Notes Refer to Signature Loop Controller Installation Sheet for wiring specifications. NFPA 72 requires that the GSA-CR/GSA-MCR be installed in the same room as the device it is controlling. This requirement may not apply in all markets. Check with your local AHJ for details. ,4 The GSA-U106R and the GSA-U102R do not come with TB1 4. A The GSA-U106 does not come with TBB through TB13. z Supervised and power-limited. If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical Code. 7) Maximum #12 AWG (2.5mm2) wire. Mm. #18 (0.75mm2). Normally Open Common Normally Closed __ 1k __ 1234 + 4 - 4N A 1 11+ TB7A TB14 T .. TB15 C. 1234 No connections required for MCR. Other modules may require connections. GSA-MCR Control Relay Green LED (Normal) Red LED (Active) No connections required for MCR. Other modules may require connections. Page 3of6 DATA SHEET M850010239 Not to he usnd for In lltiou purpose, Issue 7.4 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1 .0mm2), #14 AWG (1.50mm2) and #12 AWG (2.50mm2) wire sizes. Note: Sizes #16 AWG (1 .0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. A84G A134G AB4G Audible Base Audible Base Audible Base Listed 24VDC Nominal Powei Suppl Signature Controller sounderbase GSA-MCRR GSA-CAR Schematic GSA-MCRR Schematic Powerlin Ptnoes Out POkullY Recesses - oACtt20ted Power in Power Out == - 62044-003 .__I I I COL Relay Audible 2 = I I required for Bases ..s_ S supevision us us 0 0 0 I. Notes Refer to the Signature controller installation sheet for wiring. One Pair of Wires (24 Vdc power). One Pair of Wires (Signature Data). Single Wire (24 Vdc power). The GSA-U106R and the GSA-U102R do not come with TB14. The GSA-U106 does not come with TB8 through TB13. Supervised and power-limited. 8 If the source is nonpower-limited, maintain a space of 1/4 inch from power-limited wiring or use FPL, FPLP, FPLR, or an equivalent in accordance with the National Electrical code. 9 Maximum #12 AWG (2.5 m2 ( wire; Minimum #18 AWG (0.75mm2). 10 End-of-Line Relay must monitor and report power supply trouble to control panel. 11 Class B Data wiring may be "T-tapped." Signature — Data Data Out Circuit I.JL/ULC Listed L T 24 Vdc power — supply or —o 1234 Data Out + Signature 1 .. Data L 3 . Circuit Data In — •• /Jv-II Green LED Norrnall 1 2 3 ,1 2 3 Red LED (Active) \/Optional MCRR or MCR for disabling/disconnecting I No connections required for MCRR on audible base, I modules may require connections. . . For normal operation CT1 For General Fire Alarm Operation MCRR UIOCRI series inotherboard l 3 Na connections required for I McRR. Other modules may require Connections. Green LED Normal) I Red LED lActivel L—f co ectionsrequireor TOlD I IMc Other modules may - reautre Connections. Page 4 of 6 , DATA SHE ST M85001-0239 Not to be usod toil iisfallation uuroses. Issue 7.4 Specifications Catalog Number GSA-CR GSA-MCR GSA-CRR GSA-MCRR Description Control Relay Polarity Reversal Relay Type Code Personality Code 8 (Factory Set) Personality Code 8 (Factory Set) Address Requirements Uses 1 Module Address - Operating Current Standby= lOOpA Activated = 100liA Operating Voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Relay Type and Rating Form C, 2 Amps @ 24 Vdc (pilot duty), 0.5 Amps @ 120 Vac and 0.25 Amps @ 220 Vac (220 Vac is non-UL). Not rated for capacitive loads. Mounting North American 21/2 inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates Plugs into U102R, U106R or U106 Motherboards North American 21/2 inch (64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates Plugs into U102R, U106R or U106 Motherboards Construction & Finish High Impact Engineering Polymer Storage and Operating Environment Operating Temperature: 32°F to 120°F (0°C to 49°C) Storage Temperature: -4°F to 140F (-20°C to 60°C) Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled On-board Red LED - Flashes when in alarm/active Compatibility Use With: Signature Loop Controller Agency Listings UL, ULC, CSFM, MEA Ordering Information Catalog Number Description Weight - lbs Ship (kg) GSA-CR Control Relay Module (Standard Mount) 0.4 (0.15) GSA-MCR Control Relay Module (UIO Mount) 0.18(0.08) GSA-CAR Polarity Reversal Relay Module (Standard Mount) 0.4 (0.15) GSA-MCRR Polarity Reversal Relay Module (UIO Mount) 0.18(0.08) Related Equipment 27193-11 Surface Mount Box - Red, 1-gang 1(0.6) 27193-16 Surface Mount Box - White, 1-gang 1(0.6) GSA-U102R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) GSA-U106R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) GSA-UI06 Universal Input-Output Module Board - Six Module Positions 0.56 (0.25) GSA-AB4G Audible (Sounder) Detector Base 0.3 (0.15) Accessories MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0(3.1) GSA-M B4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4 (0.15) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) Page 5of6 DATA SHEET M85001 -0239 Not to be used for installation purposss. Issue 7.4 Signature Series Overview The Signature Series intelligent analog-addressable system from Edwards is an entire cbwAR DS family of multi-sensor detectors and mounting bases, multiple-function input and output AUTC Fire &S untyCo ' modules, network and non-network control panels, and user-friendly maintenance and Detection & alarm since 1872 service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature U.S./Canada device measures and analyzes the signal and decides whether or not to input an alarm. T 888 244 9979 The microprocessor in each Signature device provides four additional benefits - Self-di- F 866 503 3996 agnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Southeast Asia Stable Communication. T : +65 6391 9300 F : +65 6391 9306 Self-diagnostics and History Log - Each Signature Series device constantly runs self- checks to provide important maintenance information. The results of the self-check are India automatically updated and permanently stored in its non-volatile memory. This information T+91 804344 2000 F +91 80 4344 2050 is accessible for review any time at the control panel, PC, or using the SIGA-PRO Signa- ture Program/Service Tool. The information stored in device memory includes: Europe T+322 725 11 20 Device serial number, address, and type F +32 2721 8613 Time and date of last alarm Latin America Most recent trouble code logged by the detector - 32 possible trouble codes may be T 305 593 4301 used to diagnose faults. F 305 593 4300 Automatic Device Mapping —The Signature Data Controller (SDC) learns where each utcfireandsecurity.com device's serial number address is installed relative to other devices on the circuit. The © 2011 UTC Fire & Security. SDC keeps a map of all Signature Series devices connected to it. The Signature Series All rights reserved. Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits between each device can be examined. Layout or 'as-built" drawing information showing branch wiring (T-taps), device types and their address are stored on disk for printing hard copy. This takes the mystery out of the installation. The preparation of as-built drawings is fast and efficient. Device mapping allows the Signature Data Controller to discover: Unexpected additional device addresses Missing device addresses Changes to the wiring in the circuit. Most Signature modules use a personality code selected by the installer to determine their actual function. Personality codes are downloaded from the SDC during system configu- ration and are indicated during device mapping. Standalone Operation -A decentralized alarm decision by the device is guaranteed. Onboard intelligence permits the device to operate in standalone (degrade) mode. If Sig- nature loop controller CPU communications fail for more than four seconds, all devices on that circuit go into standalone mode. The circuit acts like a conventional alarm receiving circuit. Each Signature device on the circuit continues to collect and analyze information from its slave devices. When connected to a panel utilizing standalone operation, modules with their "personality" set as alarm devices (lDC) will alarm should their slave alarm-initiat- ing device activate. Page 6of6 DATA SHE S I M850010239 Not to btt usoci icr S tai tat ton purEotes, Issue 7.4 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1483:0115 Page 1 of I CATEGORY: 7300 -- FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@fs.utc.com DESIGN: Models GSA-CC1, GSA-CC2, GSA-CT1, GSA-CT2, GSA-CR, GSA-CRR, GSA-UM, GSA-MMI, GSA-WTM, GSA-IM, GSA-MCC2, GSA-MCT2, GSA-MCR, GSA-MCRR, GSA-MAB, GSA-MCC1, GSA-MDM remote transponders; Models GSA-U106, GSA-U106R and GSA-UI02R motherboards. Models MFC-A and MFC-AD enclosures. Models GSA-MP1, GSA-MP2 and GSA-MP2L mounting plates. *Model GSA-CR2 Control Relay Module. Refer to listees data sheet for additional detailed product description and operational consideration. RATING: 15.2- 19.95 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as remote transponders for use with separately listed compatible fire alarm control units. XLF: 7300-1657:0121 *Rev. 6-9-11 ma e This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct AM operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division Input Modules GSA-Cit GSA-CT1 HT, GSA-CT2, GSA-MCT2 7 191LA Pi T TM Fire & Life Safety Intelligent Input-Output GSA-MCT2 I Apollcaon Nwes - Ava,Iab!o Overview The GSA-CT1 Single Input Module, GSA-Oil HT High Tempera- ture Single Input Module and GSA-CT2/GSA-MCT2 Dual Input Modules are intelligent analog addressable devices used to con- nect one or two Class B normally-open Alarm, Supervisory, or Monitor type dry contact Initiating Device Circuits (lDC). The actual function of these modules is determined by the "personal- ity code" selected by the installer. This code is downloaded to the module from the Signature loop controller during system configura- tion. The input modules gather analog information from the initiating devices connected to them and convert it into digital signals. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. - The GSA-CT1, GSA-CT1 HT and GSA-CT2 mount to standard North American 1-gang electrical boxes, making them ideal for lo- cations where only one module is required. Separate I/O and data loop connections are made to each module. The GSA-Oil HT module operates at an expanded temperature range of 32 IF to 158 OF (0 00 to 70 00) for those applications requiring more extreme environmental temperature variation. The GSA-MCT2 is part of the UIO family of plug-in Signature Series modules. It functions identically to the GSA-CT2, but takes advantage of the modular flexibility and easy installation that characterizes all UlO modules. Two- and six-module UlO mother- boards are available. All wiring connections are made to terminal blocks on the motherboard. UIO assemblies may be mounted in Edwards enclosures. Standard Features Multiple applications Including Alarm, Alarm with delayed latching (retard) for water- flow applications, Supervisory, and Monitor. The installer selects one of four "personality codes" to be downloaded to the mod- ule through the loop controller. GSA-CTI HT rated for high temperature environments Suitable for attic installation and monitoring high temperature heat detectors. Plug-in (UIO) or standard 1-gang mount UIO versions allow quick installation where multiple modules are required. The 1-gang mount version is ideal for remote loca- tions that require a single module. Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. Electronic addressing Programmable addresses are downloaded from the loop con- troller, a PC, or the Signature Program/Service Tool. There are no switches or dials to set. Stand-alone operation The module makes decisions and inputs an alarm from initiat- ing devices connected to it even if the loop controller's polling interrogation stops. (Function availability dependent upon control panel.) Ground fault detection by address Detects ground faults right down to the device level. Page 1 of 4 DATA SHEET M85001 -0241 Not to be usod bc jns1ailation purposes. Issue8 Signature Series Overview The Signature Series intelligent analog-addressable system from Edwards Security is an entire family of multi-sensor detectors and mounting bases, multiple-function input and output modules, network and non-network control panels, and user-friendly main- tenance and service tools. Analog information from equipment connected to Signature devices is gathered and converted into digital signals. An onboard microprocessor in each Signature de- -vice measures and analyzes the signal and decides whether or not to input an alarm. The microprocessor in each Signature device provides four additional benefits - Self-diagnostics and History Log, Automatic Device Mapping, Stand-alone Operation and Fast, Stable Communication. Self-diagnostics and History Log - Each Signature Series device constantly runs self-checks to provide important mainte- nance information. The results of the self-check are automatically updated and permanently stored in its non-volatile memory. This information is accessible for review any time at the control panel, PC, or using the Signature Program/Service Tool. Automatic Device Mapping —The Signature Data Control- ler (SDC) learns where each device's serial number address is installed relative to other devices on the circuit. The SDC keeps a map of all Signature Series devices connected to it. The Signature Series Data Entry Program also uses the mapping feature. With interactive menus and graphic support, the wired circuits be- tween each device can be examined. Layout or "as-built" drawing information showing branch wiring (1-taps), device types and their address are stored on disk for printing hard copy. Installation GSA-CT1, GSA-CT1 HT and GSA-CT2: modules mount to North American 21/2 inch(64 mm) deep 1-gang boxes and 11/2 inch (38 mm) deep 4 inch square boxes with 1-gang covers and GSA-MP mounting plates. The terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mrire size. Compatible electrical box Wall plate, white (1-gang) C. is LEDs LED viewing ports • ". GSA-MCT2: mount the UIO motherboard inside a suitable Edwards enclosure with screws and washers provided. Plug the GSA-MCT2 into any available position on the motherboard and secure the module to the motherboard with the captive screws. Wiring connections are made to the terminals on the motherboard (see wiring diagram). UIO motherboard terminals are suited for #12 to #18 AWG (2.5 mm2 to 0.75 mm2) wire size. Page 2 of 4 UlO Motherboard 6-32 Self-tapping screws J ocaPHve Module screws ye Flat washers Cabinet or electrical enclosure Electronic Addressing - The loop controller electronically ad- dresses each module, saving valuable time during system com- missioning. Setting complicated switches or dials is not required. Each module has its own unique serial number stored in its on-board memory. The loop controller identifies each device on the loop and assigns a "soft" address to each serial number. If desired, the modules can be addressed using the Signature Pro- gram/Service Tool. Edwards recommends that this module be installed according to latest recognized edition of national and local fire alarm codes. Application The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is de- termined by their sub-type code or "Personality Code". The code is selected by the installer depending upon the desired application and is downloaded from the loop controller. One personality code can be assigned to the GSA-CT1. Two per- sonality codes can be assigned to the GSA-C12/MCT2. Codes 1, 2, 3 and 4 can be mixed on GSA-CT2/MCT2 modules only. For example, personality code 1 can be assigned to the first address (circuit A) and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM - LATCHING (Personality Code 1) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors, etc. An ALARM signal is sent to the loop controller when the input contact is closed. The alarm condition is latched at the module. NORMALLY-OPEN ALARM - DELAYED LATCHING (Person- ality Code 2) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterfiow Alarm Switches. An ALARM signal is sent to the loop controller when the input contact is closed for approximately 16 seconds. The alarm condition is latched at the module. NORMALLY-OPEN ACTIVE - NON-LATCHING (Personality Code 3) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring input such as from Fans, Dampers, Doors, etc. An ACTIVE signal is sent to the loop controller when the input contact is closed. The active condition is not latched at the module. NORMALLY-OPEN ACTIVE - LATCHING (Personality Code 4) - Assign to one or both circuits. Configures either circuit A or B or both for Class B normally open dry contact monitoring input such as from Supervisory and Tamper Switches. An ACTIVE signal is sent to the loop controller when the input contact is closed: The active condition is latched at the module. DATA SHEET M85001-0241 Not to be 0205 for irtOtallOtiort purposes, Issue 8 Typical Wiring Modules will accept #18 AWG (0.75mm2), #16 (1.0mm2), and #14AWG (1 .50mm2), and #12 AWG (2.50mm2) wire sizes Note: Sizes #16 AWG (1.0mm2) and #18 AWG (0.75mm2) are preferred for ease of installation. See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating (Slave) Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms (25 ohms per wire) per Circuit Maximum Allowable Wire Capacitance 1 0.1pF per Circuit For Design Reference: Wire Size I I Maximum Distance to EOLR #18 AWG (0.75 mm2) #16 AWG (1.00 mm2) #14 AWG (1.50 mm2) #12 AWG (1.50 mm2) 4,000 ft (1,219 m) L\LsStyle B (Class B) TB2 Red LED (Alarm/Active) TB] f DATA IN(.)> 1 DATA IN(-) > From Signature Controller or Previous Device A Typical N.C. Initiating Device 87 . DATA OUT (+) DATA OUT (-) To Next Device Typical N.C. Initiating Device INPUT 1 UL/ULC ListedStyle B (Class B) 471(1<2 EOL Li\ L'i\ Red LED (Alarm/Active) DATA IN (+)> DATA IN(-)>_____ From Signature Controller or Previous Device UL/ULC Listed 471<0 EOL Green LED (Normal) INPUT 2 I UL/ULC Listed 471<1) EOL Green LED (Normal) .DATA OUT (+) DATA To Next Device GSA-CT1, GSA-CT1 HT NOTES Maximum 25 Ohm resistance per wire. L Maximum #12 AWG (2.5 mm2) wire; Minimum #18 AWG (0.75 mm2). Refer to Signature controller installation sheet for wiring specifications. Maximum 10 Vdc @350 pA The GsA-ul06R and the GSA-U102R do not come with TB14. 6 All wiring is supervised and power-limited. 7 These modules will not support 2-wire smoke detectors Warnings & Cautions This module will not operate without electrical power. As fires fre- quently cause power interruption, we suggest you discuss further safeguards with your local fire protection specialist. Compatibility The Signature Series modules are compatible only with Vigilant's Signature Loop Controller. GSA-CT2 lyrical NO Iniboting Oeain -L I ffl uuc47— EOLLcsaced I Sd 5—/ \_j AAA f !.C" rr±U±1F4 1234 s10—ic + Othr OacaoicJ nnsdicIarnayraian G,een LEO lNa,nadr RSLEDIACI,vel NIan ooctio 1xiiindlo, Inca GSA-MCT2 Page 3 of 4 DATA SHEET M850010241 Not to be used for 4iIlation purposes. issue Specifications Catalog Number GSA-CT1HT I GSA-Cu GSA-CT2 I GSA-MCT2 Description Single Input Module Dual Input Module Type Code 48 (factory set) Four sub-types (personality codes) are available 49 (factory set) Four sub-types (personality codes) are available Address Requirements Uses One Module Address Uses Two Module Addresses Operating Current Standby = 250pA; Activated = 4001JA Standby = 396pA; Activated = 680lJA Operating voltage 15.2 to 19.95 Vdc (19 Vdc nominal) Construction High Impact Engineering Polymer Mounting North American 21/2 inch (64 mm) deep one-gang box- es and 11/2 inch (38 mm) deep 4 inch square boxes with one-gang covers and GSA-MP mounting plates U102R/6R/6 Motherboard Operating Environment 32°F to 158°F (0°C to 70°C) 32°F to 120°F 0°C to 490 Storage Environment -4°F to 140°F (-20°C to 600C); Humidity: 0 to 93% RH LED Operation On-board Green LED - Flashes when polled; On-board Red LED - Flashes when in alarm/active. Both LEDs - Glow steady when in alarm (stand-alone) Compatibility Use with Signature Loop Controller Agency Listings UL ULC, MEA, CSFM Ordering Information Catalog Number Description Ship Wt. lbs (kg) GSA-CT1 Single Input Module - UL/ULC Listed 0.4 (0.15) GSA-CT1 HT Single Input Module High Teperature Operation UL/ULC Listed 0.4(0.15) GSA-CT2 Dual Input Module - ULJULC Listed 0.4(0.15) GSA-MCT2 Dual Input Plug-in (UIO) Module - UL, ULC Listed 0.1 (0.05) Related Equipment - 27193-11 Surface Mount Box - Red, 1gang 1.0(0.6) 27193-16 Surface Mount Box - White, 1-gang 1.0 (0.6) GSA-U102R Universal Input-Output Module Board w/Riser Inputs - Two Module Positions 0.32 (0.15) GSA-UIO6R Universal Input-Output Module Board w/Riser Inputs - Six Module Positions 0.62 (0.28) GSA-UlO6 Universal Input-Output Module Board - Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet - Red, supports Signature Module Mounting Plates 7.0 (3.1) GSA-MB4 Transponder Mounting Bracket (allows for mounting two 1-gang modules in a 2-gang box) 0.4(0.15) GSA-MP1 Signature Module Mounting Plate, 1 footprint 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate, 1/2 footprint 0.5 (0.23) GSA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02 (0.46) WARDS UTC Fire & Security Company Detection & alarm since 1872 U.S. T 888 244 9979 F 866 503 3996 Canada T 705 875 2659 F 705 944 8861 Southeast Asia T: +65 6391 9300 F : +65 6391 9306 India T: +91 80 4344 2000 F : +91 80 4344 2050 Europe T+322725 1120 F+322721 8613 Latin America T305 593 4301 F 305 593 4300 utcfireandsecurity.coni © 2010 UTC Fire & Security. All rights reserved. 0 P Page 4of4 DATA SHEET M85001-0241 1p Not to be used for installation purposes. Issue 8 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 00-,"0 LISTING No. 7300-1483:0115 Page 1 of 1 CATEGORY: 7300— FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: MIRTONE*8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 Fax (941) 308-8123 Email: rhonda.micochero@fs.utc.com DESIGN: Models GSA-CC1, GSA-CC2, GSA-CTI GSA-CT2, GSA-CR, GSA-CRR, GSA-UM, GSA-MMI, GSA-WTM, GSA-IM, GSA-MCC2, GSA-MCT2, GSA-MCR, GSA-MCRR, GSA-MAB, GSA-MCCI, GSA-MDM remote transponders; Models GSA-U106, GSA-Ul06R and GSA-UI02R motherboards. Models MFC-A and MFC-AD enclosures. Models GSA-MPI, GSA-MP2 and GSA-MP2L mounting plates. *Model GSA-CR2 Control Relay Module. Refer to listees data sheet for additional detailed product description and operational consideration. RATING: 15.2 - 19.95 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as remote transponders for use with separately listed compatible fire alarm control units. XLF: 7300-1657:0121 *Rev. 6-9-11 ma * This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not ' ¶1 an endorsement or recommendation of the item listed. This listing should not be used to verify correct V operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division INSTALLATION AND MAINTENANCE INSTRUCTIONS "S cb a $ SENSOR CD RTS151 3825 Ohio Avenue, St. Charles, Illinois 60174 OUUOiN.JI'L, rtA ou-/(-oqD Remote Test Station www.systemsensor.com SPECIFICATIONS Dimensions: 4.8" H x 2.90" W x 1.4 D Weight: .16 lbs. Power Requirements Alarm LED: 2.8 - 32 VDC, 10 mA max. Coil Current: 95 mA max. Test Switch: 10 VA @ 32 VDC Reset Switch: 10 VA @ 32 VDC Alarm Response Time: 40 sec. max. Temperature: -10°C to 60°C (14°F to 140°F) Humidity: 95% RH Non-condensing Max Listing: UL, FM, CE NOTE: RTS151 replaces RTS451. FIGURE 1. RTS151 REMOTE TEST STATION: T% NOTICE: This manual shall be left with the owner/user of this equipment.. NOTE: A test coil is required only for use with D2/DNR/DH400/DH500 mod- els. For D2 models order part #DCoiI. For the DH400/500 models order part is #Coil. GENERAL INFORMATION System Sensor's RTS151 is an automatic fire detector accessory designed to test a remotely located detector. Consult detector installation instructions for additional information. The National Fire Protection Association has published codes, standards, and recommended practices for the installation and use of the above product. It is recommended that the installer be familiar with these requirements, with local codes, and any special requirements of the local authority having jurisdiction. RTSI5I. CONTENTS 1 RTS151 remote test station 1 screw pack (2 mounting screws) 1 M02-04 test magnet WIRING OF RTS151 Consult the appropriate detector installation instructions for the applicable wiring diagram. The RTS151 mounts to a single gang box (2 /2" minimum depth), or directly to the wall or ceiling. See Figure 8 for wiring diagram of RTS1S1 with Duct Smoke Detectors. In Canadian applications, the RTS151 is intended to be located in the same room as the smoke detector and within 60 feet of the unit. OPERATION Test Function Place and hold the painted side of the magnet to the test location RTS151. Alarm Indication With the magnet in place some time will elapse (40 sec. maximum) depend- ing on the detector type, before the alarm indicating LED will light. Reset Function Gently insert a 1/8 maximum diameter tool into the hole until it stops and LED turns off. The RTS151 is capable of resetting only certain System Sensor models of detectors. Refer to detector installation instructions for additional information. 'In I , M1 N, H0t96-01 FIGURE 2 WIRING DIAGRAM FOR RTS151 TO D4120 4-WIRE DUCT SMOKE DETECTOR: H0582-20 FIGURE 3. WIRING DIAGRAM FOR RTS151 TO DNR 2-WIRE DUCT SMOKE DETECTOR WITH REMOTE TEST CAPABLE HEAD: TEST COIL+ TEST COIL — 1/AT51KE1 ,, RTS151/RTS15IKEY COMM + : OUT (CONV ONLY) + COMM - RA/RTS— 3 :JUMPER RA + RTS + H0633-00 D440-01-00 1 . 156-0469-014 FIGURE 4. WIRING DIAGRAM FOR RT5151. TO D2-2 WIRE DUCT SMOKE DETECTOR: MAGNET IN + TEST COIL I ) + TEST COIL TEST SWITCH -TEST COIL I 24VDC I AUX POWER I 24VDC AUXPOWERI SUPPLIED I 4 MAGNET TEST -TEST COIL ( SUPPLIED BY USER SWITCH BY USER _________ (lOOmA [,,_ + IN + IN (100mA SUPPLY) H ® + OUT SUPPLY) ___________ _______________ ___________ + OUT ALARM 24 VAC (+10%, -15%) 24 VAC (+10%, -15%) ( > LED (RED) [ O - FULL WAVE RECTIFIED, UNFILTERED POWER FULL WAVE RECTIFIED, [ MAYBE USED UNFILTERED POWER MAY BE USED ALARM LED (RED) - - -RA -RA RTS151 (OPTIONAL) REM + RA (OPTIONAL) REMOTE + RA TEST STATION + RTS TEST STATION + RTS D2 D2 METHOD #1 - AUX POWER LOCATED METHOD #2- AUX POWER LOCATED AT DUCT DETECTOR AT TEST STATION NOTE: THE USE OF THE RTS151 REQUIRES THE INSTALLATION OF AN ACCESSORY COIL, DCOIL, SOLD SEPARATELY. H0612-11 FIGURE S. WIRING DIAGRAM FOR RTS15I. TO DH100ACDC 4-WIRE FIGURE S. WIRING DIAGRAM FOR RTS1S1 TO DHLOO 2-WIRE DUCT DUCT SMOKE DETECTOR: SMOKE DETECTOR: DH100ACDC RTS151 DH100 RTS151 Alarm Signal + tj (Red LED) Alarm Test + Test Aux. Power - Test/Reset— Reset+ Reset ® Reset RA+ 1\> Reset LED Field -"-[ Installed Jumper RA—112r Z~~ Test Test V Out + No Connection H0197-01 H0198-04 FIGURE 7. WIRING DIAGRAM FOR RTS151. TO DH400ACDC DUCT FIGURE S. WIRING DIAGRAM FOR RTS1S1. TO BEAMI.224/ SMOKE DETECTOR- BEAM1224S SMOKE DETECTOR: UM400AUUU ALARM SIGNAL (~) AUX POWER (-) )- 3 RESET (-) 4 TEST(—) RTS1 51 413 RESET TEST H0149-02 BEAM1 224/BEAM1224S REMOTE ALARM OUT AUX (-) RESET INPUT REMOTE TROUBLE OUTPUT TEST INPUT OPTIONAL V ELLA W LEO RTS151 LED) ALARM RESET TEST H0586-03 Three-Year Limited Warranty System Sensor warrants its enclosed product to be free from defects in materials and S . 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing workmanship under normal use and service for a period of three years from date of the malfunction and suspected cause of failure. The Company shall not be obligated to manufacture. System Sensor makes no other express warranty for the enclosed product, replace units which are found to be defective because of damage, unreasonable use, No agent, representative, dealer, or employee of the Company has the authority to in- modifications, or alterations occurring after the date of manufacture. In no case shall the crease or alter the obligations or limitations of this Warranty. The Company's obligation Company be liable for any consequential or incidental damages for breach of this or any of this Warranty shall be limited to the replacement of any part of the product which other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by is found to be defective in materials or workmanship under normal use and service the Company's negligence or fault. Some states do not allow the exclusion or limitation of during the three year period commencing with the date of manufacture. After phoning incidental or consequential damages, so the shove limitation or exclusion may not apply System Sensor's toll free number 800-SENSOR2 (736-7672) for a Return Authorization to you. This Warranty gives you specific legal rights, and you may also have other rights number, send defective units postage prepaid to: System Sensor, Returns Department, RA which vary from stale to stale. D440-01-00 2 156-0469-014 02011 System Sensor CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1653:0129 Page.1 of 1 CATEGORY: 7300 - FIRE ALARM CONTROL UNIT ACCESSORIES/MISC. DEVICES LISTEE: System Sensor, Unincorporated Div of Honeywell Int'l lnc.3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 Fax (630) 377-7245 Email: trish.linhartsystemsensor.com DESIGN: Models RMK400 and SMB-600 smoke detector mounting kits. Model RMK400 recessed mounting kit is intended for use with System Sensor's listed Models 5451, 5551, 5551R, 1451, 2451, 2151, 2251; Notifier's Models SDX-551, CPX-551, FDX-551, FDX-551R and Honeywell's listed Models TC806A Series, TC806B Series, TC807A Series, TC804C Series, TC805C Series and TC804D Series smoke detectors. Model SMB-600 surface mounting kit is intended for use with System Sensor's listed Models 1451, 2451, 2551, 1551; Notifier's listed Models SDX-551, CPX-551, and Honeywell's listed Models TC806A-1003 smoke detectors. Refer to listee's data sheet and the smoke detector listings (CSFM) for additional detailed product description and operation consideration. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model designation and UL label. APPROVAL: Listed as smoke detector mounting kit for use with Models described under 'Design". NOTE: Formerly 7300-1209:177 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed ial., the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct WPV operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other Date Issued: July 01, 2012 Listing Expires June 30, 2013 Authorized By: JASON DEWITT, Deputy State Fire Marshal Fire Engineering Division