Loading...
HomeMy WebLinkAbout1281 CARLSBAD VILLAGE DR; ; AS150219; Permit11/3/2020 AS 150219 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS150219 1281 CARLSBAD Job Address: Status: APPROVED VILLAGE DR Permit Type: SPRINK Applied 7/27/2015 Parcel No: 1561907010 Approved: 7/27/2015 Lot #: 0 Reference No.: Issued: 7/27/2015 PC #: Inspector: Project Title: PACKARD DENTAL OFFICE Applicant: INNOVATIVE FIRE PROTECTION INC STE 101 8779 COTTONWOOD AV SANTEE CA (619) 593-8200 (619)593-9133 Owner: CARLSBAD MEDICAL VILLAGE L P C/O RUSS RIES P 0 BOX 1422 LA JOLLA CA Fees ($) Add'I Fees ($) 1Total ($)Balance 280 0 280 0 1/1 Bulletin 014 Rev. M liable Model Fl FR Series Quick Response Glass Bulb Sprinklers C CD CD SO Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model Fl FR56 Recessed Sprinkler Types Standard Spray Pendent Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types -. Standard Spray Upriht Standard Spray Pendent Model F1FR40 Sprinkler Types Standard Spray Pendent Model F1FR42, F1FR40, F1FRXLH & F1FR28 Recessed Sprinkler Types Standard Spray Pendent Model Fl FR56LL & Fl FR42LL NSF Certified Low Lead Sprinkler Types Standard Spray Pendent with less than 0.25% Lead Content Upright Pendent Conventional 1RiT1 L LJL!1_J Vt tiLcil Sidewall - Bor'zontal Sidbwall - . Recessed - PendentlFl/F2 Recessed Concealed Recessed Horizontal Sidewall Pendent PendentjFP XLH Upright XLH Pendent XLH Recessed Pendent F1/F2 1, Underwriters Laboratories Inc. and Certified for Canada (cULus). FM Approvals (FM) Loss Prevention Certification Board (LPCB) Vertrauen durch Sicherheit (VdS) NSF Certified to NSF/ANSi Standard 61 Annex G (NSF) EC Certificate: 0786-CPD-40239 (RA1414), 0786- CPD-4025 1 (RA1425), 0786-CPD-40252 (RA1 475) (EC) UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler kler. Product Description AS150219 Reliable Automatic Sprinkler Co., Inc., 103 Listing & Approvals The following organizations provide Listings or Approvals for various Model F1FR series sprinklers. See the Design and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- Reliable Model F1FR series sprinklers . are quick-response automatic sprin- klers with a glass bulb thermal element - Model F1FR series sprinklers are Stan- -, dard Spray sprinklers, with the excep- tion of the Model F1FR56 Conventional XLH Recessed sprinkler which is an Old-style/Conven- Pendent FR tional sprinkler. The Model F1FR Series automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrat- ed response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR Series sprinklers to apply water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Fairview. Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid Model F1FR Series sprinklers must be installed with the in both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands, forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinkler joint Uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-M). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model Fl FR Series sprinklers provide a wide range of op- sprinkler. tions where* quick-response, glass bulb sprinklers are used: Recessed Sprinklers Pendent, recessed pendent, upright, horizontal side- Model F1FR Series Recessed sprinklers are to be installed wall, and vertical sidewall deflectors as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed. The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons Flush, recessed, and concealed installations that are permitted to be used with each Model F1FR Series See the Design and Installation Information table in this Recessed sprinkler. The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model F1FR series sprinkler configurations. Concealed Sprinklers Model F1FR Recessed Pendent and Recessed Horizon- Model F1FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig. 4 or Fig. 5, as applicable to the Model Fl, F2 or FP recessed escutcheons. See the Re- selected cover plate. Model F1FR56 Concealed Pendant cessed Escutcheon Data table in this Bulletin for listing and and Model Fl FR56LL Concealed Pendent sprinklers have aooro9l1nformbenithreachspecbc.Modei FTFR series .T a .ffor tltqdMd'djcPoA;..d.rpteptLve C is, in: Model Fl and F2'iCce5Cd dcutci ieons, shown it i stalled at the factory that SFdd remain on the 'sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on I (19mm) and 1/2-inch (12.7mm) of adjustment, respectively, the sprinkler until the cover plate is installed. The concealed Model FP recessed escutcheons, shown in Fig. 2, provide a sprinkler assemblies are completed by the installation of a 1/2-inch (12. 7mm) threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1FR56 Concealed Pendent and Model F1FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates. A standard profile Model CCP coy- ment. A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch (12.7mm) of provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover cover plate adjustment. In addition, a low profile Model CCP adjustment. Do not install Model F1FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.0mm) of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model AOl wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model Fl FR Series sprinklers are intended for use in protective cap to install the sprinkler, then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hay- ing the wrench from the sprinkler/cup assembly, care should be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating, deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is com- in accordance with the requirements of the applicable plated by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the cup. Final adjustment is made Fl FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirl flange makes full their listings and approvals, as well as the information contact with the ceiling. Cover plate removal requires turning the provided in this Bulletin, cover plate in the counter clockwise direction. After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping, han- free from any air flow impediment to the space above. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers. The use of any concealed cover place. Remove the bulb protector at the time when the sprin- plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1FR56 Concealed Pendent and Model F1FR56LL of the bulb protector before this time may leave the bulb vul- Concealed Pendant sprinklers or the use of the Model CCP nerable to damage. Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with which clasp by hand. Do not use tools to remove bulb protectors. it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-RI/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) Design and Installation Information Nominal Nominal Listings Mod Orifice Deflector! Sprinkler Installation SIN and Approval Diameter Orientation Height Wrench Notes I Approvals inches mm inches mm I Pendent 225 57 0 RA1411 cULus 2 F1FR2 3/8 10 Recessed Pendent 225 57 GFR2 RA1411 cULus 2 A26 Upright 225 57 0 RA1421 cULus 1,2 I Pendent 225 57 0 RA1418 VdS F1FR4 3/8 I 10 Recessed Pendent 225 57 GFR2 RA1418 VdS Pendent 225 57 D RA1413 cULus 2 F1FR4 7/16 10 Recessed Pendent 225 1 57 GFR2 RA1413 cULus 2 Upright 225 1 57 D RA1423 cULus 1,2 I Pendent 225 57 0 RA1410 cULus, NSF F1FR42LL 42 10 60 7/16 I .Heessed_Pendeot 225-+--_5,.-7-.-,FR2 RA141O -cUbos;NSF'. :-FFLkLh . ' Fndeit 25 57 -HGJL& (Fl FR42 4 2 60 7/16 10 Recessed Pendent 2 25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 225 57 D RA1423 cULus 1,2 Pendent 225 57 D 1 LPC8,VdS,EC RA1414 cULus, FM. i__J Recessed Pendent 225 57 GFR2 RA1414 LPCB,VdS,EC 1,2,34 F1FR56 5.6 80 1/2 15 concealed Pendent 225 57 1 RC1 i RA1414 cULus, VdS. EC 5,6 Upright 225 57 D RA1425 cULus FM LPCB,VdS,EC 1,2,3,4 Conventional ,, (Pendent or Upnght) 225 57 D HA 1475 LPCB, VdS, EC I 4 Pendent 225 57 D RA1415 cULus, NSF 1 F1FR56LL 5,6 80 1/2 15 Recessed Pendent 225 1 57 GFR2 RA1415 cULus, NSF Concealed Pendent 225 1 57 RC1 RA1414 cULus, NSF 6 Horizontal Sidewall 263 1 67 D RA1435 cULus, FM 123,7 F1FR56 56 80 1/2 15 Recessed Horizontal Sidewall 263 67 GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 /2 15 Vertical Sidewall 225 57 D RA1485 cULus FM 1,23,9 (Pendent orUpright) LPCB cULus Listed corrosion Resistant sprinkler when ordered with available Polyester coating. CULLIS Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white, 'fl Available with LPCB and VdS approved Polyester coating. VdS and EC approvals 01 the F1FRS6 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12. 7mm) adjustment Model CCP cover plate only. Model F1FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. cULus Listing of the F1FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the FlFR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the F1FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The F1FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the F1FR56 Vertical Sidewall sprinkler is for installation in the Pendant position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification 100°F (38°C) Max. Ambient 150°F (65°C) Max. Ambient 225°F (107°C) Max. Deflector! Model Temp. Temp. I Ambient Orientation 135°F (57°C) 155°F (68°C) 175°F (79°C) I 200°F(93°C) 286°F (141°C) Temp. I Temp. Rating Temp. Rating Temp. Rating Temp. Rating Rating Orange Bulb Red Bulb Yellow Bulb Green Bulb Blue Bulb Pendent cULus F1 FR28 Recessed Pendent cULus Upright cULus Pendent VdS F1 FR40 Recessed Pendent VdS Pendant cULus F1FR42 Recessed Pendent cULus L I Upright cULus IF1FR42LL/ Pendent -- cULus, NSF -- Recessed Pendent cULus, NSF - Pendent cULus F1FRXLH Recessed Pendent cULus -- - ,HAndent Recessed Pendent - - - JLs FM, L'C8 cULus, FM, LPCB, VdS, EC F1FR56 Concealed Pendent cULus cULus,VdS,EC cULus Upright CULUS, FM, LPCB, VdS, EC Conventional (Pendant or Upright)" LPCB VhS EC Pendant -- cULus, NSF -- F1FR56LL Recessed Pendent -- cULus, NSF -- Concealed Pendent" -- cULus, NSF -- Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal Sidewall I cULus, FM T -- F1FR56 Vertical Sidewall (Pen- dent or Upright) cULus, FM, LPCB * Model F1FR56 Concealed Pendent and F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Model Deflector! (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendant cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendant cULus, NSF cULus, NSF cULus, NSF RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 F1FR56 Recessed Pendant cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC R,A1414 EC VdS, EC F1FR56LL Recessed Pendant cULus, NSF cULus, NSF cULus, NSF RA1415 F1FR56 Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 c I -,A 2 5/8" 0/A. [66.7mm] HOLE IN CEILING 2 5/16" 0/A. [58.7mm] -- -- - CUP CEILING FACE OF FITTING TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS = 1-1/2738mm] AT MINIMUM RECESS = 1 '[25.4mm] 2 1/4 HOLE 0/A. f57.2] LLEUHEON_ ADJUSTMENT F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT 2 27/32 0/A. [72.2r] I" X 1/2" REOUCER FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS I 725.4mm] AT MINIMUM RECESS = 3/8 79.5mm] / F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4719mm] AT MINIMUM RECESS = 3/8(9.5mm] Fl ESCUTCHEON AT MAXIMUM RECESS = 7/8722.2mm] fJ.2j I / AT MINIMUM RECESS = 1-5/8741.3mm] r F2 ESCUTCHEON - AT MAXIMUM RECESS = 1- 1/8 728.6mm] ./IT.MINIMUM.RSCCSS.,,i-5/8741.3mm] TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS Fig. 1 Mode! F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR42LL, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Mode! Fl or F2 escutcheon IX 1/2" REDUCER J AT MAX/MUM RECESS = 9/167i3mm] AT WINIMUM RECESS 1'[25.4m-] 3 1/4" 0/A. [82.6mm] Fig. 2 Mode! F1FR56, F1FR56LL, F1FR42, F1FR40, F1FR421-L, F1FRXLH & F1FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. 2 5/16" 0/A - CUP CEILING 1 ESCUTCHEON MAX/MUM RECESS = 1-3/8"[34.9mm] AT MINIMUM RECESS = 2-1116'T52 .4mml F2 ESCUTCHEON AT MAX/MUM RECESS = 1-5/8"[41.3mm] AT MINIMUM RECESS = 2-1/16 '[52.4mm] FACE OF FITTING ro FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAX/MUM RECESS = 1 '[25.4mm] AT MINIMUM RECESS = 3/8 "[9.5mm] F2 ESCUTCHEON AT MAX/MUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8 '[9.5mm] 2 1/4" HOLE 0/A. [5 7.2mm] 1" X 1/2" REDUCER 2 27/32" 0/A. [72.2mm] TURN COLLAR UNTIL - TIGHT AGAINST SPRINKLER WRENCH 80-5.5 .ELESCUTCUN .. .... F2 ESCUTCHEON 1/2"[12.7mm] ADJUSTMENT RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [101.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR El BOW 1I11:: HOLE IN CEILING 1 1/2" MAX. FACE OF FITTING TO FACE OF CEILING DIMENSION 1/2" MAX. COVER ADJUSTMENT COVER PLATE ASSEMBLY / 3 5/16' 0/A SPRINKLER CONCEALED, 1/2" ADJUSTMENT Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model COP cover plate 1 ---r--- 11 15/16" DIA.4 [49.2mm] - (1) 4"-12" [101. 6mm-304.8mm] CEILING TO DEFLECTOR I" x 1/2 REDUCING TEE OR ELBOW 'J T J" 0/A 2 5/16 0/A - _______ - r' HOLE IN CEILING CUP 00 vu 1 112 MAX. FACE OF FITT-ING TO FACE 0 CEILING 5/16 MAX. // 3/4 COVER ADJUSTMENT COVER PLATE / I I ASSEMBLY 3 5/16 0/A. SPRINKLER CONCEALED, 5/16" ADJUSTMENT 07EG02A ..p}g: v.rc3cJe .36 /.3tL : 5/16-inch (8.0mm) adjust Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) I Iinichc Sprinkler Escutcheon over plate'11 Bronze - Chrome Chrome Plated _Brass Chrome White Polyester Plated Coated "" White Painted on Finishes l Electroless Nickel Electroless Nickel PTFE'71 PTFE Bright Brass Lqsin lit _Brass'3> Bright Brass Black Plating Black Plated Black Plated Black Paint BlackkPntI2w Black Paint Oft White Whiteihilvi 011 White Satin Chrome _chrome Dull Chrome Dull Other finishes and colors are available on special order, Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. ' cULus listed corrosion resistance' applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA 1475. cULus listed Corrosion Resistant 7 eiceaiec' r-erioeHt SpnkeF w,tn iow prattle ment - Model CCP cover plate Material Data Frame: DZR Brass, GM Brass, or Low Lead Brass Deflector: CDA Alloy 220, 260, or 510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651 or 693 Washer: Nickel Alloy 440 or 360, coated with PTFE Adhesive Tape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28J[F1 FR4O][F1 FR42] [Fl FR42LL][F1 FRXLH][F1FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent][Recessed Fendent][Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal 5idewa11][Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (57°C)][155°F (68°C)][1 75°F (79°C)][200°F (93°C)][286°F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile COP 1/2-inch (12.7mm) adjustment][low profile COP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers • Deluge valves Flush automatic sprinklers • Detector check valves Recessed automatic sprinklers • Check valves Concealed automatic sprinklers • Electrical system Adjustable automatic sprinkl ers • Sprinkler emergency cabinets 'i .1 - Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliable Automatic Sprinkler Co., Inc. Recycled (800) 431-1588 Sales Offices Paper Reliable (800) 848-6051 Sales Fax Revision lines indicate updated or new data, (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address CC, Prided in U.S.A. 06/15 P/N 9999970300