HomeMy WebLinkAbout1299 CARLSBAD VILLAGE DR; ; FA100064; Permit11/3/2020 FA1 00064 Permit Data City of Carlsbad Fire Alarm Permit 1299 CARLSBAD Job Address: VILLAGE DR Permit Type: FALARM Parcel No: 1561907001 Lot #: 0 Permit No: FAI 00064 Status: ISSUED Applied 10/13/2010 Approved: 10/13/2010 Reference No.: Issued: 10/13/2010 PC #: Inspector: Project Title: STEVEN A. BEULIGMANN, DDS TWO FIRE ALARM INSPECTIONS @ $65/EA Applicant: JJJ ENTERPRISES 533 S VINEWOOD ST ESCONDIDO CA 760-747-3050 Owner: CARLSBAD MEDICAL VILLAGE L P C/O RUSS RIES P0 BOX 1422 LA JOLLA CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 1/1 mr4flop EHUF.F'FF'mF.2 FIRE ALARM - SECURITY - LOW VOLTAGE SYSTEMS H am STEVEN A BEULIGMANN, DDS 1299 CARLSBAD VILLAGE DRIVE CARLSBAD, CA 92008 FIRE ALARM SYSTEM CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, conditions in correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit or approve the violation of any law. By &kDO2\.- Date_____ STEVEN A BEULIGMANN, DDS 1299 CARLSBAD VILLAGE DR. CARLSBAD, CA 92008 BILL OF MATERIALS DMP XR5FC FIRE ALARM CONTROL PANEL CSFM# 7165-1157:104 DMP 690F REMOTE FIRE COMMAND KEYPAD CSFM# 7165-1157:124 DMP 521 B/BXT SMOKE DETECTOR CSFM# 7272-1657:277 DMP 850S PULL STATION CSFM# 7150-1157:112 SYSTEM SENSOR P2R TWO WIRE H/S WALL MOUNTED RED CSFM# 7125-1653:188 PIBV2 SUPERVISORY SWITCH CSFM# 7770-1653:118 SIGNALING NYC MEA LISTED Econornice. ti - 3:mrner :-Ions TIT. :1 XRS commercial fire and slave communicators from DMP are perfect for small commercial installations that require reliable, cost-effective monitoring. Built-in 2-line dialer 500mA auxiliary power One Class A (Style D) zone for sprinkler supervision Four Class B (Style A) smoke-detector zones Four Class B (Style A) expansion zones Rely on DMP to increase the value of your next fire alarm installation. High-quality DMP panels and network monitoring technologies have led the industry for decades and significantly reduce the cost of monitoring communications. XR5 9 ZONE PANEL, ++++: SYSTEM FEATURES One Class A (Style D) waterfiow zone Four Class B (Style A) 2-wire smoke detector zones Four Class B (Style A) expansion zones using 714 or 715 lOOmA 12 VDC switched 4-wire smoke power (XR5FC) Two Form C relay outputs optional Four open collector outputs for annunciation Built-in dual phone line module with line monitoring Built-in bell circuit trouble monitor, connects to Model 865 or 866 Notification Circuit Modules 600mA alarm bell dutput (XR5FC) 500m4.auxiliary. output Opérate on 16 VAC power .44ire keypad and annunciator circuit 16 event history, can be viewed fdrd 630F keypad DMP Serial 1 or Contact ID communication formats Compatible with the iCOMsL for network/ Internet reporting Programmable reporting to one or two central stations Remote upload/download with Remote Link Built-in plain English programming from any keypad Individual zone programming for fire, fire verification, retard delay, cross-zoning, and fire supervisory Compatible with 630F and 692F keypads Fire Drill-feature for practice evacuations Swinger bypass option on all zones Inherent power Limited circuits Automatic recall test reporting One-man Walk Tst + + Au dmticstandbç battery test Each XR5 panel contains a built-in dual phone line module with line supervision that can communicate to one or two remote receivers using DMP Serial 1 digital dialer or Contact ID (CID) formats. You can also selectively enable alarm, supervisory/ trouble, backup, and recall test reporting to either of the two receivers. An iCOMsL Network Alarm Communicator connects to the XR5 to provide Internet/ LAN /WAN communications to the panel. When used in this manner or as a slave or stand-alone network communicator, the iCOMsL reduces or eliminates costly telephone Lines and communicates to the central station via high-speed network connections. Conduct one-man tests of the system and all connected devices using the Walk Test feature. Simply enter an access code into the keypad and XR5 panels automatically enter test mode. Each time a zone trips during the test, the bell rings for two seconds and a Sensor Reset is automatically performed to reset latched detectors. When the test is completed, the results display at the keypad and can be sent to the central station. The 714 provides four inputs and is suitable for use with normally open and normally closed fire devices. 714 inputs are supervised and can be programmed for any zone type. The 714 connects to the keypad bus. .. 1. The 715 expander provides four Class B powered inputs and is suitable for use with the 2-wire conventional smoke detectors. 715 inputs are supervised and can be programmed for any zone type. The 715 connects to the keypad bus. The built-in false alarm reduction features include cross zoning, fire verification, fire retard, and CleanMe reporting. Cross zoning allows multiple zones to be cross zoned and reports alarms only when two or more zones fault within a programmable time of 4 to 250 seconds. Should just one zone trip, only a zone fault report is sent to the central station. Fire verification provides a 120-second window during which a smoke detector can trip, be automatically reset, and then must trip a second time before an alarm is indicated. A single trip on the zone sends only a zone fault report to the central station. Fire retard allows a programmable time of up to 250 seconds for waterflow detection. This eliminates the need for additional mechanical delays at the flowswitch. Four open collector outputs can be used for a variety of remote control and annunciation applications. Each output is rated for 50mA maximum. Add the Model 860 Relay Output module to provide four form C relay contacts. Each Model 305 relay is rated at 42mA and the module easily mounts inside the XR5 enclosure. T For slave communicator applications, the XRSSL provides an enclosure door- mounted Model 377 Trouble Annunciator Module. The Model 377 offers Trouble and System OK LEDs with audible alert and a Silence button for acknowledging trouble conditions. An internal English text Programmer enables technicians to easily program and test the panel from any keypad . A lockout code restricts access to only authorized persons. Remotely program XR5 panels using Remote Linklm programming software from DMP. You can upload panel programming, make the necessary programming changes, and then download the revised programming into the panel. Expand Remote Link/System Link functionality with Advanced Reporting, Alarm Monitoring, Command Center, or Link Server packages. For system annunciation, include the DMP 630F Fire Command keypad in your installation. This 20-key, 32-character LCD annunciator provides full-text displays of system events and menu prompts. It can be used for system operation, annunciation, and programming. The 630F is protected by either a keyswitch or code. The keyswitch enables the four function buttons: Silence, Reset, Test, and Fire Drill. Install the 630F using the included backbox and trim frame for Rush-mount applications and the 635-R backbox for surface mount applications. The 630F has the ability to annunciate all on-board and expansion zones on the XR5. The 692F Fire Command LED Keypad offers 5 sets of highly visible LED annunciation of alarm and trouble conditions. It provides individual zone alarm and trouble LEDs for zones one to five only. Also, system LEDs, an internal sounder, 2-button Fire alarm initiation, and only Silence, Reset, and Fire Drill functions are provided. The 692F is used in applications where only the panels five on-board zones are used. Model 377 Trouble Silence/Reset AnnunciatorPanel Module Silence/Reset F±1 EJ SilencReset 0 Telephone Bell g Monitor IC Direct connect Lu tnswitched 120 VAC 60 1-0 AC vvi—ln I 'I 21 31 1 5 6I 16.5 VAC 4OVA L (4) (4) (s ® Secondary Power Supply Z r2 VDC 2 AmpsMae uhatgilrgcurrerrl. ~G~U~ 1 C old WatstPip. Earth Ground Up to 500rrrA auxiliary current at 12 VDC from IerrrnineI 7 Keypad Model 63SF — 63mA at 8.5 to 14 VOC 1 1 ED CE - Relay Sockets for Optional Forts C Outputs on Ill UI I L ,L Output Header Jil I (, n'." 3.3k I I I I Output Header J12 S 33k O Four Open Coilnoter Outputs. or mm Resister 50 mA at 30 VDC resistive output r output 2 0 0 Mad 1309 tine Model 300 Harness V1 y m g Zone t P11 2 2 Two Furor C ISPDTl Outputs. Zone 2 Zone 3 Zone 4 33k Ohs 3.3k Ohm 3.3k Ohm Supervised Circuit Keypad = Model 692F ca ca 30mA ale to 16 VDC. CD=m c cj mm mC=) 5 Zone LED Keypads XR5FC System Configuration Diagram MDnow Digital Monitoring Products FARE COiY1AD f(EYPADS 630F Remote Fire Command 32-character LCD 635-R Keypad Conduit Backbox 692F Fire Command Keypad 377 Trouble Annunciator Module (included with XR5SL) 860 Relay Module 865 Style W/X Notification Circuit Module 866 Style W Notification Circuit Module iCOMSL Network Alarm Communicator EXPANSION MODULES 714 4-zone Class-B Expansion 715 4-zone 2-wire smoke Expansion POWER SUPPLIES 504-24 Provides 4 Amps ® 24 VDC 504-24LX Provides 4 Amps ® 24 VDC 505-12 Provides 5 Amps® 12 VDC 505-12L Provides 5 Amps ® 12 VDC 505-12LX Provides 5 Amps® 12 VDC COMPUTER SOFTWARE Remote Link Upload/Download Programming Software System Link End-User Management Software Advanced Reporting Module Alarm Monitoring Module Command Center Module Link Server Application OETfCTORS SLR-835B Photoelectric Smoke 521 B/BXT Addressable Smoke, CleanM& AC CESSDRJES 300 Plug-in Harness 305 Plug-in Relay Output 306 Harness Connection 318 Dual Battery Harness 320 40 VA Wire-in Transformer 367 12 VDC 7.7Ah battery 370RJ Lightning Suppressor with Two RJ Jacks SPECFCATONS . LISTINGS AND APPROVALS Primary Power 16.5 VAC 40VA transformer (Model 320) Refer to the XR5 Installation Guide (LT-0229), XRS Programming Guide Secondary Power 12 VDC 7.7Ah battery (Mode( 367) (LT-0312) and specific compliance listings for installation and Outputs programming requirements necessary to meet a particular Auxiliary 500mA® 12 VDC approval. Annunciator 50mA each (switched ground) California State Fire Marshal (CSFM) XRSFC Outputs . FCC Part 15 Alarm 600mA® 12 VDC FCC Part 68 . Smoke lOOmA @ 12 VDC New York City (MEA) Enclosure Red (Models 340FC or 340SL) Underwriters Laboratories (UL) Listed Dimensions 12.5" x 9.5" x 3.75" ANSI/UL 864 Control Units for Fire-Protective Signaling Systems Material 20-gauge cold-rolled steel For additional information, access www.dmp.com and select Compliance. ------------------------- - 2500 North Partnership Boulevard ...........................................................--- ........................-........-.-.-..- ....-..-----, ......................... Digital Monitoring Products . . . ' . ' - Springfield, Missouri 65803-8877 ...........-. -.. -........................................................................................-..-.... CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:104 Page 1 of 1 CATEGORY: Fire Alarm Control Unit (Commercial) LISTEE: Digital Monitoring Products, 2500 N. Partnership Blvd., Springfield, MO Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 tshelton@dmp.com DESIGN: Model XR5FC and XR5SL fire alarm control units. Automatic, manual, noncoded, local, remote station, central station, waterfiow and sprinkler supervisory service. Model XR5SL does not employ a bell output circuit or 4-wire detector power, it is used for slave applications deriving its power from the host (master) control unit. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR5FC, XR5SL Control Panels 630F*, 692F Keypad 865, 866 Bell Module 320 Power Transformer 377 Trouble Indicator Module *714, *715 Zone Expanders INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units for use with separately listed electrically and functionally compatible initiating and indicating devices. The control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instructions Manual for details. This control unit meets the requirements of UL Standard 864, *9th Edition. NOTE: For Alarm Verification Feature, the maximum Retard/Reset/Restart (including smoke detector reset time) shall not exceed 30 seconds. *Rev. 02-19-09 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division admmr ,Sam ""Am-la LISTED DMP Fire Command Keypads provide a variety of fire annunciation solutions for residential and commercial fire applications. Using the 692F Fire Command Keypad, alarm and trouble conditions on XR5FC and XR5SL Commercial Fire Panels display on the highly visible LED annunciator. Simple one-button operation to silence alarms, reset sensors, test the system, and perform afire drill make the 6301 easy to operate. The 6301, 690F, and 790F Fire Command keypads from DMP 32-character full text LCD readout displays system events and menu prompts that make the keypads efficient and easy-to-use. 692F, 630F.0 690F1 AND 790F KEYPADS FIRE COMMAND CENTER FEATURES 630F FEATURES Simple harness connection to4-wirekeypad bus • 32-character LCD display At-a-glance system status • Flush or Surface mount Powered from panel or auxiliary power supply • Keyswitch enables single button operation Optional backboxes for conduit or wall mount applications • Full operation with authorized code Attractive non-obtrusive designs • Built-in diagnostics 2-button Panic keys • AC Power, Trouble, Alarm LED 92F FEATURES • compatible with XR2400F, XR200, or XR200-485 Three status LEDs: Silenced, Trouble, and Power • System events in plain English 10 zone LEDs: 5 Trouble LEDs and 5 Alarm LEDs No addressing required - use as many as you need Zone monitoring fe4t drq for all zones 6901F/790F FEATURES 32-character LCD display Compatible with all DMP panels RETROFIT EXISTING DMP SYSTEMS Designed to allow easy retrofitting, the Fire Command' keypads are compatible with all existing DMP panels. DW recommends using the 692F with the XR5 panel. Adding a keypad does not require new wiring, special modules, or panel upgrades. You can provide a new look and greater functionality to an existing system at just a fraction of the cost for all new equipment. 2-BUTTON PANIC KEYS The Fire Command Keypads allow the top row of keys to be used as 2-button Panic keys. This feature lets the user press and hold two of the keys simultaneously to send a Panic, non-medical Emergency (options not available on 692F), or Fire Alarm report to the central station. An adhesive Label is provided with the keypads to identify the Panic keys to the user. KEYBOARD BACKLIGHTING The Fire Command keypads also illuminate the keyboard in green whenever a key is pressed or the internal buzzer sounds. This allows users to enter their code or perform a command function in very low Light conditions. This option is not available on the 630F Keypad. RED ALARM BACKLIGHTING The keypads offer one of the most unique features found on any keypad. During an alarm condition on the system, the keyboard backlighting turns a bright red. This change in color from the normal green backlighting helps people on-site to instantly recognize an alarm condition. This option is not available on the 630F Keypad. BUILT-IN DIAGNOSTICS An internal diagnostics program Lets installers and service technicians test the operation of the keypad at any time without disabling the system. The diagnostics program tests the keypad's prewarn tone, LCD segments and backlighting, each of the keyboard's 16 keys, and the 790F keypad's four protection zones. This option is not available on the 692F Keypad. SUPERVISED AND UNSUPERVISED OPERATION You can program the keypads for supervised or unsupervised operation on the keypad data bus. When supervised, the keypad occupies its own address. Unsupervised operation allows you to install multiple keypads on the bus with the same address. This feature greatly increases the overall number of keypads you can install to provide maximum flexibility in operating the system. The 692F is always unsuper'iscd. 692F FIRE COMMAND KEYPAD The 692F Fire Command Keypad offers highly visible LED annunciation of alarm and trouble conditions on DMP XR5FC and XR5SL Commercial Fire Panels. The 692F provides individual zone alarm and trouble LEDs, status LEDs, an internal buzzer, 2-button functions. The 692F also includes an easy-to-read backlit keyboard with large alphanumeric characters. The 692F is cased in a stylishly designed, durable red plastic housing with removable base for easy installation. STATUS LEDS The green Power LED lights when primaryAC or DC power- to the panel is at an acceptable Level and flashes when its battery is low or missing. A yellow Trouble LED turns on when either the panel has failed to communicate with the central station receiver or when phone line 1 or 2 is in a bad condition. The 692F also uses a yellow Silenced LED to indicate when the panel's Belt Output has been silenced. ZONE LEDS Ten zone LEDs indicate the status of the zones. Each zone has a trouble and alarm LED to indicate at-a-glance zone status. KEYPAD FUNCTION KEYS There are four clearly labeled function keys on the 692F keypad. The SILENCE, RESET, TEST, and CODE function keys allow the user to press one key to initiate operations. As added security measure, the user must enter a valid security code after pressing one of the function keys. 630F REMOTE ANNUNCIATOR The 630F Fire Command Center from DMP offers high quality, cost effective fire system control with an easy-to-use keyboard interface. The 32-character full text LCD readout displays system events and menu prompts making the 630F keyboard efficient and easy-to-use. SINGLE-BUTTON OPERATION The 630F Fire Command Center Keyboard has a factory installed keyswitch that enables the four function buttons—Alarm Silence, System Reset, System Test, and Fire Drill. The user can also access these functions through the User Menu by entering a valid user code at the Keyboard. USER MENU Users can access all of the functions necessary to operate and maintain their system right from the keyboard User Menu. These function include Alarm Silence, Reset Sensors, and Display Events. MOUNTING The 630F comes with its own backbox and trim frame, providing an attractive installation. The keypad can either be flush- mounted or surface-mounted. 690F/790F FIRE COMMAND KEYPADS Both 690F and 790F Fire Command keypads provide a 32-character LCD display, a Large backlit alphanumeric keyboard, and an internal multi-tone speaker. Users can perform all system functions from the Wmmds including arming, disarming, bypassing zones, and silencing alarms as well as choosing any of the User Menu options. The 790F Security Command Keypad also provides four Class B protection zones for use in a variety of fire applications. FOUR PROTECTION ZONES To save the expense and potential service problems inherent in "home-running" your security devices to the panel, the 790F Fire Command Keypad provides four fully programmable Class B protection zones you can use for a variety of burglary and fire applications. Multiple Fire Command keypads can also be installed on the same wire run to increase the cost savings of each installation. USER SELECTABLE OPTIONS Each keypad provides a simple User Options menu through which users can change the display and speaker characteristics of the keypad. Simply holding the COMMAND and Back Arrow keys down for two seconds causes the keypad to display SET BRIGHTNESS. Once in the menu, the user can adjust the several options to customize the keypad for personal preferences. DISTINCT SOUND PATTERNS The 690F and 790F Fire Command Keypads also provide distinct sound patterns or burglary alerts, fire alerts, door monitors, and prewam that can help users identify an event occurring on their system. USER MENU Users can access all of the functions necessary to operate and maintain their system right from the keyboard User Menu. These function include Alarm Silence, Reset Sensors, and Display Events. The User Menu is restricted so that a valid user code is required before access is granted to any of the functions. This protection allows you to install the keyboard in even high traffic public areas without danger of unauthorized access. fllglt.I Monitoring Products KEYPAD REFERENCE CHART Keypad zones Display Type Panic Keys Compatible Panels Keyboard Red in Alarm User Brightness Operating Voltage Operating Current 630F Fire Command None LCD Yes XR200, XR2400F, No and XR200-485 Yes 12 VDC lOOmA; lOOmA 6OF Fire Command None LCD Yes All Yes Yes 12 VDC lOOmA; lOOmA 692F Fire Command None LED Yes XR5FC/SL No Yes 12 VDC 30mA; 7OmA 7OF Fire Command Four LCD Yes All Yes Yes 12 VDC lOOmA + 1.6mA per acbve zone; 100mA + 2mA per zone in alarm 692F SPECIFICATIONS Operatingbltage 8.5to15VDC Current Draw 30mA standby, 70mA maximum Dimensions 6.8" W x 5.0" H x 1. 1 " D Panel Compatibility XR5FC and XR5SL 630F SPECIFICATIONS Operating Voltage 8.5to15VDC Current Draw 100m.4 Trim Frame Dimensions 10.4"Wx 7.0" H 1.7" D Backbox Dimensions 8.75" W x 6.375" Hx2.5" D Panel Compatibility XR200, XR2400F and XR200-485 690F1790F SPECIFICAlONS -. Operating bltage 8.Oto'i6 VDC. 690F Current Draw nt4standbyand alarm / 790F Current Draw loo zone (? ALarm: lOOmA + 2mA per active zone Dimensions 68"Wx5.0"Hx1.1"D Panel Compatibility ALL [WviP Command cessor" Panels Now KEYPAD ACCESSORIES 695 1.5" Keypad Conduit Backbox 696 1/2 Keypad Backbox 699 Keypad Deskstand WR-0004 4-wire Replacement Harness WR-0012 12-wire Replacement Harness WR-0512 5-foot 12-wire Replacement Harness LCD Keypad Housing LED Keypad Housing Note: Backboxes not compatible with 630E APPROVALS a UL 864 Control Units for Fire Protective Signaling UL 985 Household Fire UL294Access Control UL 985 Household Fire Warning UL 1076 Proprietary Burglar UL 1023 Household Burglar UL 1610 Central Station CSFM 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-1157:124 Page 1 of 2 CATEGORY: LISTEE DESIGN: Control Unit (Non High-Rise) Digital Monitoring Products, 2500 N. Partnership Blvd., Springfield MO 65803 Contact: Terry Shelton (417) 831-9362 Fax (417) 831-1325 tshelfon©dmp.com Model XR2500F *combination fire and burglary alarm control unit. Local, remote station, proprietary, and central station services. Refer to listee's data sheet for additional detailed product description and operational considerations. System components: XR500 322, *323, *327 725 716 717 630, *6) 690, 693-790 791, 79f793 7060, 7060A, 7160, 7063, 7063A, 7163, 7070, 7070A 7170, 7073, 7073A, 7173 866 893A 710F 481, 462N, 462P *461 714, 714-8, 714-16, 715, 711 715-8, 715-16, 725 860 865, 867, 869 893A 733,734 303 710 1100x 1101, 1102, 1103 Main Board Transformer Adaptor Zone Expander Output Expander Annunciator Module Supervised LCD Keypad Supervised LCD Keypad *LCD Keypads *LCD Keypads *LCD Keypads Indicating Module Dual Phone Line Module Bus Splitter *Interface Card Interface Adaptor *Zone Expanders *Zone Expanders *Relay Module *Indicating Module *Dual Phone Line Module *wegand Interface *ReseVSilence Switch *Bus Splitter *RF (Wireless) Receiver *Wreless Transmitters RATING 16 VAC 56VA INSTALLATION In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. Listing No. 7165-1157:124 Page 2 of 2 APPROVAL: Listed as a fire alarm control unit for use with separately listed electrically and functionally compatible initiating and indicating devices. Intended for use with separately listed Models 521LX and 521LXT (CSFM Listing No. 7272-1157:106) 2-wire photoelectric type smoke detectors or Model SLRLX (CSFM Listing No. 7300-1157:122) 2-wire smoke detector base. Refer to listee's Installation Instruction Manual for details. This control unit does not generate a temporal pattern signal. if the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required the control unit must be used with appliances that can generate the temporal pattern signal. This control unit meets the requirements of UL-864, 8th Edition Standard. NOTE: For Fire Alarm Verification Feature (delay of fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. Rev. 04-24-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division ¶iYES L PRODUCT INFORMATION BULLETIN CleanMe remote maintenance reporting reduces false alarms Smart dual fixed/rate of rise heat works with photo chamber to catch fires faster Built-in drift lI.1l.1:TsIui•4 Field replaceable optical chamber makes servicing a snap Small, low profile design blends in with any environment (((IeanMe® COMPATIBLE Low Profile, Self-Diagnostic, Two- Wire, Photoelectric Smoke Detector with CleanMe® UL Model numbers: 52113, 521 BXT, 52ICRXT ULC Model numbers: 52813, 528BXT ,~ 9. California State Fire Marshal Approved LISTED The ESL 521 Series self-diagnostic, two-wire smoke detectors are the industry's first conventional direct-wire smoke detectors with analog features such as remote maintenance/trouble reporting (CleanMe®), drift compensation, and multi-criteria detection. The 521 Series continually monitor their own sensi- tivity and operational status, and provide a visual and remote trouble condition if they drift out of the sensitiv- ity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. The 521 has a unique feature enabling it to send a signal (CleanMe) to the ESL 505 module (sold separately) when it has drifted outside of its UL Listed sensitivity range or has failed its internal diagnostics test. The 505 is an interface module that will signal a 24V panel via relays when the 521 is dirty. Several 12V and 24V control panels have the CleanMe software built in, eliminating the need for the 505 module. When CleanMe is not desired, simply leave the switch on the 521 off and it will work as a normal two wire detector. CleanMe allows the installer time to schedule a service call and avoid a false alarm. Time between cleaning detectors is dramatically increased because of the 521's built-in drift compensa- tion. This feature, usually only available in analog systems, allows the detector to automatically adjust its sensitivity over time as it becomes dirty, increasing the life of the detector. And when the 521 has told you that cleaning is necessary, it's literally a snap with ESL's patented field replaceable optical chamber. continued 521 Series ESL Photoelectric Smoke Detectors The multi-criteria model 5218XT/CRXT photoelectric smoke detector/fixed rate of rise heat detector includes fast response algorithms for a quick response to both flaming and smoldering fires. Fast response algorithms allow the heat detectors to work intelligently together with the photo- electric smoke detector. As soon as the heat sensor detects a rapid rise in temperature, the sensitivity of the photoelec- tric sensor increases allowing it to detect smaller particles of combustion faster. Architectural and Engineering Specifications The ESL 521 Series photoelectric smoke detector is a low- profile, self-diagnostic two-wire detector that monitors its own sensitivity and operational status. This detector meets NFPA 72 field sensitivity requirements without the need for external meters. Built-in drift compensation automatically adjusts the sensitivity as the detector gets dirty. Normal sensing occurs every 9 seconds. This rate doubles when a signal exceeding the alarm threshold value is sensed. Two additional successive signals above the threshold level will initiate an alarm. See installation instructions for information about correct installation and maintenance. The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Dimensions: 2 (5cm) (12L Specifications: Product Data Voltage: Dip switch 1 "on" ...................6.5-33VDC, polarity sensitive Dip switch 1 "off' ..................8.5- 33VDC, polarity sensitive Maximum ripple (pk to pk) .....................................10% (V ) Typical average standby current (24V) ..........................70°iA Typical alarm current (24V) ..........................up to 60mA max (if not limited by control panel) Alarm Contacts ............................500mA@36VDC (resistive) Aux. Relay contacts ...........................................1A@ 30VDC Sensitivity (photoelectric) ........................3.1% + 0.50-1.00% Operating temperature ................32°F to 100°F (01 to 37°C) Operating humidity range .............0 to 95% Non-condensing RFI Immunity ...........................20V/m minimum; 0-1000MHz Field wiring size ...................................................12-24 AWG Heat detector specifications: Rate of rise .... 15*F/min and >105°F (8.3°C/mm, >40.6°C) Fixed ...............................................................135°F (57°C) UL two-wire compatibility identifier: Dip switch 1 "on" ..........................................................SO9A Dip switch 1 "off' ..............................................S10A, S11A Drift compensation adjustment...........................1.0%/ft. max Reset time ................................................. 1 second minimum Detector head dimensions: Diameter ...............................................................5" (12cm) Height......................................................................2" (5cm) Mounting dimensions: Diameter ......................................................4.75" (12.5cm) Height..............................................................0.3" (0.8cm) Color ...................................................White head and base Detector packaging............................10 detectors per carton Listings ..........................................................UL, ULC, CSFM Model No. Description 521 B 2-wire, photoelectric, 6-24VDC with CleanMe®, UL listed 521 B-1OPK 10 pack of 521B (not individually boxed) 521 BXT 2-wire, photoelectric, 6-24VDC with CleanMe, multi-criteria algorithms, fixed/rate of rise smart dual heat, UL listed 521BXT-10PK 10 pack of 521BXT (not individually boxed) 521 CRXT 2-wire, photoelectric, 1 2-24VDC with CleanMe, auxiliary relay, multi-criteria algorithms, fixed/rate of rise smart dual heat, UL listed 528B 2-wire, photoelectric, 6-24VDC, ULC listed 528BXT 2-wire, photoelectric, 6-24VDC with CleanMe, multi-criteria algorithms, fixed/rate of rise smart dual heat, ULC listed Accessories 505 Module that interprets the 521's CleanMe signal for the panel and can convert 2-wire 521 Series to 4-wire inputs on panel 401 Test magnet in plastic shell for pole mounting SM-200 Smokel in a Can® (canned smoke) for functional testing of smoke detectors 211 Replacement optical chambers (set of 10) j interIogi ,. PH 503.692.4052 USA & Canada: 80047.2556 IT44UII& Technical Service: 800.648.7424 Faxhack: 800.483.2495 www.sentroI.com wvinterIogixsecur4y.com E-4224 Rev 8-1101 2001 I,,te,lngi, e In(e,Iogi,. Cadd, ESL. ITI and senvnl are trademarks of Inta,ogikv CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL - FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1657:277 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: GE Security Inc. 8985 Town Center Parkway, Bradenton, FL 34202 Contact: Jewell Micochero (941) 739-4358 FAX (941) 308-8123 Rhonda.micocheroqe.com DESIGN: Models 521B, 511C*, 511 AFT*, 521BXT, 521CRXT (2-wire) and 541C, 541CXT, 541AXT (4-wire) photoelectric type smoke detectors. Model 521BXT, 521CRXT, 541CXT, 51 1AFT*, and 541AXT smoke detectors employ a supplemental heat sensor to assist the smoke detector in fire situation. This heat sensor is not a heat detector and is not intended for use in lieu of the required heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 6.5 - 33 VDC INSTALLATION: In accordance with listees printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric type smoke detectors for use with separately listed electrically compatible fire alarm control units. FORMERLY: 7300-0447:140 *Rev. 06-05-2000 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listees data sheet installation instructions and/or other suitable information sources. Date Issued: OCTOBER 19, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division LISTED The 850 Series Fire Alarm Pull stations offer quick and simple operation that's economical and reliable. Available in single or dual-action manual pulls SPST contacts and terminal strip connections Gold-plated contacts to avoid the risk of corrosion Approvals: UL and CSFM • Mounts on standard single-gang box Americans with Disabilities Act (ADA) compliant • Optional surface and weatherproof backboxes available Die-cast metal construction • High-gloss red enamel finish Reset key • Scored acrylic breakrod The DMP 850 Series Fire Alarm Pull Station is a high quality, die-cast metal manual pull station available in either single-action or dual-action configurations with SPST contacts and terminal strip connections. The normally open contact, which closes when the pull station is activated, is rated for 1 Amp @ 30 VDC. The contacts are gold-plated to avoid corrosion risks. Scored acrylic breakrods are used with the 850 series. COMPLIANCE The 850 series has been tested by UL for compliance to the latest requirements of the ADA. :\ TI OPT A variety of mounting options are available for the 850 series. It can be flush mounted to a standard single gang switch box or surface mounted in two optional configurations. The Model 850-SB Interior Surface Backbox or the Model 850-WP Weatherproof Backbox both allow conduit connection to the 850 Series Pull Stations. 850S OPERATION The Model 850S Single Action Pull Station is operated by pulling the handle on the front of the station as far down as it goes. When the handle locks into place it is easily visible from up to 50 feet. Reset the handle by opening the station with the supplied key, placing the handle in the normal upright position and re-locking the station. .00 On the Model 850D Dual Action Putt Station, the push bar rotates inward allowing the PULL handle to be grasped in a one handed motion. ADDRESSABLE ZONE To create an addressable reporting zone for the 850 Series, install a Model 711 Zone Expansion module. PULL Screw Terminals 7 To next To Fire Alarm - device or Control Panel - EOL resistor Model 850 Wiring Diagram SP;- -NS Switch Rating 1 Amp ® 30 VDC Dimensions 4.75" H x 3.25" W x 2.25" D Color Red w/raised white letters, white PULL handle w/raised red Letters COM PAT IEU LIT Y The 850 Series Fire Pull Station is compatible with all DMP Command Processors. - M- L ' Digit'] Monitoring Product, J&L. C - .. ft-. , 850S Single-action pull station 850D Dual-action pull station 850-SB Interior surface sheetmetal backbox 850-WP Weatherproof surface die-cast backbox 850-AR Scored acrylic breakrods (1 dozen) 850S/711 Single-action pull station w/addressable module 850D/711 Dual-action pull station w/addressable module Note; All models are supplied with one scored acrylic breakrod and one key. 2500 North Partnership Boulevard Springfield, Missouri 65803-8877 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-1157:112 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Digital Monitoring Products, 2500 N. Partnership Blvd., Springfield, MO 65803 Contact: Terry Shelton (417) 831-9362 FAX (417) 831-1325 DESIGN: Models 850D (key lock, push bar) and 850S (key lock, no push bar) noncoded manual pull stations. Suitable for outdoor use when installed with Model 850-WP back box. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30VDC INSTALLATION: In accordance with listee's printed installation, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as manual pull stations for use with separately listed and compatible fire alarm control units. * These manual pull boxes meet the requirements of UL Standard 38, 1999 Edition with California amendments. XL: 7150-1408:107 *Updated 06-22-2009 fm This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation - criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 - Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division Selectable-Output Horns, Strobes, and Horn Strobes SpectrAlert* Advance selectable-output horns, strobes, and horn strobes are rich with features guaranteed to cut installation times and maximize profits. Features Plug-in design with minimal intrusion into the back box Tamper-resistant construction Automatic selection of 12-or 24-volt operation at 15 and 15/75 candela Field-selectable candela settings on wall and ceiling units: 15, 15/75, 30, 75, 95, 110, 115, 135, 150, 177, and 185 Horn rated at 88+ dBA at 16 volts Rotary switch for horn tone and three volume selections Universal mounting plate for wall and ceiling units Mounting plate shorting spring checks wiring continuity before device installation Electrically compatible with existing SpectrAlert products Compatible with MDL sync module The SpectrAlert Advance series c.tfers the most versatile and easv-0-L•se line of hcm, strobes, ard horn strobes in the industry. Wt-) white aid red p:os-ic hourings 'naIl and ceiling mounting options, and piah arJ FIRE-printed devices, SpectrAlert Advance can meet virtuallt. an/ 3PD ication requirement. Like the entLe Spectu,l€rt Advance product line, horns, strobes, arc horn s:robes include a variety of features that increase their appli':atior versati ity while simplifying installation. All devices feature plug-ir dhsigs with m nimtl intrusion into the back bo., which make insaIlEtions fast and foolproof while virtually el:minatho costl, and time-cosumi-g ground faults. Furthermore, a universal murtng plate with an o:-board shorting spring tests wring con:inuit befjre the device is nstalled, protecting devices from damage. In addition. he d-sele::ajle candela settings, automatic selection of 12-or 24--jolt -c7e-ation, and a rotery switch for horn tones with three volume r.ele:ti:nsenables insa lers to easily adapt devices to sLit a wide reiga of a:'picatior requcements. Agency Listings SIGNALING LISTED APPROVED AOI I I'V ,1 301.3312 53532 iV,000,3 MEA approved MEA4II-03-E ,h,,,eo,obe,i 11.3-3553 I RI ihn,', rh,n,,l SpectrAlert Advance Specifications aLl - - 'TI.LI iiTTT TTIL General SpectrAlert Advance horns, strobes, and horn strobes shall mount to a standard '1 x 4 x 1½-inch back box, 4-inch octagon back box, or double-gang back box, iwo-wire products shall also mourn to a single-gang 2 x 4 x 1'/B-irrch back box. A universal mounting plate shall be used for mounting ceiling and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, SpectrAlert Advance products, when used with the Sync-Circuit" Module accessory, shall be powered from a non-Coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the SyricCircuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 19, 15/75, 30, 75, 95,110,11S, 135, 150,177, and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective serVice.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing all Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have three audibility options and an option to switch between a temporal three-pattern and a non-temporal (continuous) pattero.These options are set by a multiple position switch. On four-wire products, the strobe shall be powered independently of the sounder. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync-Circuit model MDL listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 41/6 x 41r/16 x 21/8-inch back box.The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Standard Operating Temperature __- 327 to 120F (0'C to 49CC) Humidity Range 10t093%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DCJFWRr Operating Voltage Ran9e2 8 to 17.5 V (12 V nominal) or 161033 V (24 V nominal) Input Terminal Wire Gauge 1210 18AWG Ceiling-Mount Dimensions (including lens) 6.8diameter x 2.5' high (173 mm diameter x 64 mm high) Wall-Mount Dimensions (including lens) 56 Lx 4.7W x 2.5"D (142 mm Lx 119 mm W x 64 mm D) Horn Dimensions 5.6'L x4.iWx 1.3D(142 mm Lxi 19 mmWx 33 mm Dl Wall-Mount Back Box Skirt Dimensions (885-2, BBSW-2) 5.9'L x 5.0W x 2.2"D (151 mm x 128 mm W x 56 mm Dl Ceiling-Mount Back Box Skirt Dimensions (BBSC-2, BBSCW-2) 7.1" diameter x 22' high (180 mm diameter x 57 mm high) Wall-Mount Trim Ring Dimensions (sold as a pack) (TR-HS, TRW-HS( 5.7'L x 4.8W x 035' D (145 mm Lx 122 mm W x 9 m D) Ceiling -MountTrim Ring Dimensions (sold as a S pack) (TRC-HS, TRCW-HS) 6.9-diameter x 0.35' high (175 mm diameter x 9 mm high) Notes: Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. p 5, PC, and SC products will operate at 12 V nominal only for 15 and 15/75 cd, ,rxs.0305-007 UL Current Draw Data _JI 8-17.5 Volts 16-33 Volts 3-17,5 Volts 16-33 Volts Candela DC FWR DC !!g Sound IPattern l: DC '!p:[ 'a'i: Standard 15 123 128 66 71 Candela Range 15/75 142 148 77. 81 30 NA NA 94 96 75 NA NA 158 153 95 NA NA 181 176 110 NA NA 202 195 115 NA NA 210 205 Temporal High 57 55 69 75 Temporal Medium 44 49 58 69 Temporal Low 38 44 44 48 Non-ternpoial High 57 56 69 75 Non-temporal Medium 47 50 60 69 Non-temporal Low 41 44 50 50 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela Range 150. NA NA 246 220 Coded Low 40 46 . 52 50 177 NA NA 281 251 185 NA NA 286 258 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 137 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 - FWR Input -, Temporal High 136 155 88 97 112 168 190 210 218 - Temporal Medium 129 152 78 88 . 103 160 184 202 206 - temporal Low 129 151 /6 86 101 160 184 194 . 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 . 110 166 189 208 216 Non-Temporal Low DC Input 132 16-33 Volts 135 154 150 80 177 185 90 105 161 FWR Input 184 . 16-33 Volts 135 150 202 177 211 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 735 253 288 297 Temporal Medium 209 274 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 25'l 291 295 Non-Temporal Low 214 229 256 262 Horn Tones and Sound Output Data Switch Position Sound Pattern dB 8-17.5 Its DC FWR 16-33 Volts DC FWR 24-Volt Nominal Reverberant Anechoic DC FWR DC FWR 1 Temporal High 78 78 84 84 88 88 99 98 2 Temporal Medium 74 74 80 80 86 86 96 96 Temporal Low 71 73 76 76 83 80 94 89 4 Non-Temporal High 82 87 88 88 93 92 100 100 5 Non-Temporal Medium 78 78 85 85 90 90 98 98 6 Non-Temporal Low 75 75 81 81 88 84 96 92 It Coded High 82 82 88 88 93 92 101 101 Coded Medium 78 711 8S 85 90 90 97 98 Coded Low 75 75 81 81 88 85 96 92 tSertings 7, 8, and 9 are not available on 2-wire horn strobe SpectrAlert Advance Dimensions Ceiling-mount horn strobes r223 F1 C__ Wall back box skirt Ceiling back box skirt SpectrAlert Advance Ordering Information L Wall Horn Strobes P2Rt 2-Wire Horn Strobe, Standard cd*, Red P7RH 2-Wire Horn Strobe, High cd, Red P2W 2-Wire Horn Strobe, Standard cd, White P2Wl1 2-Wire Horn Strobe, High cd, White P4R 4-Wire Horn Strobe, Standard cd, Red P4RH 4-Wire Horn Strobe, High cd, Red P4W 4-Wire Horn Strobe, Standard cd, White Wall Strobes SR Strobe, Standard cd, Red SRHr Strobe, High cd, Red SW Strobe, Standard cd, White SWH Strobe, High cd, White Ceiling Horn Strobes PC2R 2-Wire Horn Strobe, Standard cd, Red PC2RH 2-Wire Horn Strobe, High cd, Red PC7W' 7-Wire Horn Strobe, Standard cd, White PC2WH 2-Wire Horn Strobe, High cd, White PC4R 4-Wire Horn Strobe, Standard cd, Red PC4RH 4-Wire Horn Strobe, High cd, Red PC4W 4-Wire Horn Strobe, Standard cd, White Ceiling Strobes SCR Strobe, Standard cd, Red SCRH Strobe, High cd, Red SCW Strobe, Standard cd, White SCWH Strobe, High cd, White Horns HR Horn, Red HW Horn, White Accessories BBS-? Back Box Skirt, Wall, Red BBSW-2 Back Box Skirt, Wall, White BBSC-2 Back Box Skirt, Ceiling, Red BBSCW-2 Back Box Skirt, Ceiling, White TR-HS Trim Ring, Wall, Red TRW-HS Trim Ring, Wall White FRC-HSFrisrr Ring, Ceiling, Red TRCW-HS Trim Rinn, Ceilinn. White Notes: Add "-P"ro model number for plain housing (noFIkE marking on coven, e.g P2R-P. Add "-SP" to model number for"FUEGO"marking on cover, e.g. P25-SP. 3: "Sr,-nndurrl rd"nvfcrs ro ctrhes that include. 15, 15/75. 30, 75, 05, 1111, und 15 randob settings "I ugh cd" refers to strobes that incluclv 135, ISO, 177, 'md 105 rurideb ccrnnnqs SYSTEM 3825 Ohio Avenue Sr. Charles, IL 60174 SENSOR Phone: 800-SENSOR?. Fax: 630-377-6495 ''' CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-1653:188 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 Fax (630) 377-7245 Trish.Linhart@systemsensor.com DESIGN: Models CHSR and CHSW Chime/Strobes. Models P2R, P2W, P2RH and P2WH Horn/Strobes two-wire type, rectangular enclosure. Models PC2R, PC2W, PC2RH and PC2WH Horn/Strobes two-wire type, round enclosure Models P4R, P4W, P4RH and P4WH Horn/Strobes four-wire type, rectangular enclosure. Models PC4R, PC4W, PC4RH and PC4WH four-wire type, round enclosure. All models are intended for indoor use only unless other wise indicated. Models may be followed by the suffix "K" indicating indoor or outdoor use, or may be followed by suffix "P' for plain housing with no lettering. "K" suffice models are suitable for outdoor applications at temperatures from -40 Degrees F to +151 Degrees F (40 Degrees C to +66 Degrees C) and are rated NEMA 4X* when used with the System Sensor weather proof back boxes models SA-WBB (Wall), *SA..WBBW (Wall), SA-.WBBC (Ceiling) and *SAWBBCW (Ceiling). Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Standard Horn/Strobes and Chime/Strobes 8— 17.5 or 16-33 VDC/FWR Hi CD Horn/Strobes 16-33 VDC/FWR INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as strobe lights suitable for hearing impaired applications when used with separately listed compatible fire alarm control units. Suitable for indoor or outdoor use, ceiling or wall mount. The audible units can generate the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition. Refer to listee's Installation Instruction Manual for details. "Rev. 12-01-08 bh This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the testresults and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MA TEO, Program Coordinator Fire Engineering Division PIBV2 Supervisory Switch System Sensor's P/B V2 supervisory switch monitors the open position of post indicator and butterfly control valves. Features NEMA 3R rated enclosure Bi-directional actuator Easy single side conduit entry Adjustable length actuator with breakaway feature Built to accommodate up to 12 AWG wire Two sets of SPDT contacts enclosed in a durable terminal block 100 percent synchronization activates alarm panel and local bell simultaneously Operating temperature range -40°F to 120°F (-40°C to 49°C) Tamper resistant cover screws Agency Listings & @ MEA LISTED 5730 (5160 v' approved 7300. 16531 IS I)W5086V 67.036 Robust Construction: The PlBV2's rugged housing is intended for indoor and outdoor use. When installed with the actuator in the vertical position, the PIBV2 is NEMA 3R rated per UL. Application Flexibility: The PIBV2 features a flexible design, which accommodates post indicator, butterfly, and many other types of wall post, recessed wall post and pressure reducing valves. The P1BV2's unique bi-directional actuator allows the unit to be installed in either rising or falling flag installations. Simplified Installation.; Installation is made easier with the PlBV2's single side condut entrance. By providing a direct conduit pathway to the electrical source, right angle fittings are not required. Installation is further simplified by the PIBV2's adjustable length actuator with a convenient breakaway feature for installation on shorter valves.This eliminates the need for cutting the shaft. Reliable Performance: The P1BV2 has 100 percent synchronization which activates the alarm panel and local bell simultaneously. In addition, the switch is de gned to operate in temperatures ranging from -40°F to 120°F (-40°C to 49'Q, The PIBV2 is equipped with tamper resistant cover screws to prevent unauthorized entry. Inside, two sets o1SPDT (Form C: synchronized switches are enclosed in a durable terminal block to assure reliable performance. PIBV2 Specifications Model shall be model number PIBV2 Post Indicator Butterfly Valve supervisory switch as manufactured by System Sensor. PIBV2 shall be installed on each valve as designated on the drawings and/or as specified herein. Switches shell be mounted so as not to interfere with the normal operation of the valve and shall be adjusted to operate within two revolutions of the valve control or when the valve flag has moved no more than one-fifth of the distance from its normal• position. The mechanism shall be contained in a weatherproof die cast metal housing, which shall provide a side entrance for 1/2 conduit and incorporate a /i NPT nipple for attachment to the valve body. A grounding provision is provided. The switch assembly shall include two switches each with a rated capacity of 10 Amp @ 125/250V AC and 2.5 Amp @ 24V DC. The cover shall contain tamper-resistant screws for which a security wrench will be provided with each switch. PI13V2 shall be Underwriters Laboratories listed for indoor or outdoor use.The PIBV2 shall be Factory Mutual, CSFM, and MEA approved. .,.. Overall Switch 41/4 -H X 3½Vs/ x 3¼D Contact Ratings Two sets of SPDT (Form C) Dimensions (10.8cm x 8.9cm x 8.2cm) 10.0 A @ 125/250V AC; 2.5 @'6/12/24V DC Shipping Weight 2 lbs. (0.9 kg) Enclosure Rating UL indoor/outdoor NEMA 313 when mounted with the actuator vertical Operating Temperature -407 to 1207 (-40CC to 49CC) Cover Tamper Switch Standard with ULC model Range . Optional for UL model, part no, 546-7000 Maximum Stem Extension 3/32" (8.0 cm) Service Use Automatic Sprinkler: NFPA 13 One or Two Family Dwelling: NFPA 13D Residential Occupancies up to 4.stories: NFPA 13R National Fire Alarm code: NFPA 72 Mounting ½NPTnipple Warranty 3years Conduit Entrances One single side open for ½" conduit U.S. Patent No, 5,213,205 Electrical Connections for PIBV2 PIBV2 Mounting Top View. . . The following are examples of Switch 1 acceptable mounting positions: CONTACT Strip Gauge SwItch 2 12s5:DVCAC R ATINGS I 2.5AMPS U___J tF Sup. Switch . Sup. Switch Actuator Vertical (Down) Actuator Horizontal to nonsilenceabie irlltlat 't. ___i--R ['1 end-of-line resistor The following mounting position is not acceptable: zone of listed FACP ie1r'i F—i P-IF Ii IF-IF-itt-fl F-i F-IF-Il [J Typical FACP Connection t Actuator Vertical 11-- j;j/ to power source loc (Pointing Up) ccrn Break wire as shown for supervision com of connection. 00 NOT allow stripped ___ wire leads to extend beyond switch Actuating Arm Breakaway Feature: Typical Local Bell Connection Ordering Information TTT: TTTTT PIBV2 Port Indicator/Butterfly valve supervisory switch PIBV2A Post Indicator/Butterfly valve supervisory switch (ULC model) . Accessories A3010-00 Replacement hardware kit (wrenches, screw pack) WFDW Replacement tamper proof wrench for cover 546-7000 Cover tamper switch kit HEXW . Replacement hex wrench S07-66-XX Tamper screws for cover SYSTEM 3825 Ohio Avenue - St. Charles, IL 60174 ".s_f 5Ej%jscF? Phone: 800-SENSOR2 - Fax: 630-377-6495 P'Ut CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE Fllt.E MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. CATEGORY: LISTEE: DESIGN: INSTALLATION: MARKING: APPROVAL: NOTE: 7770-1653:118 Page 1 of 1 Valves/Switches System Sensor, Unincorporated Div of Honeywell Int'l Inc., 3825 Ohio Ave, St. Charles, IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 Models PlBV2 and OSY2 valve supervisory switches. Suitable for outdoor use. Refer to listee's data sheet for detailed product description and operational considerations. In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Listee's name, model designation, electrical rating and UL label. Listed as valve supervisory switches for use in fire sprinkler systems. Suitable for outdoor use. Formerly 7770-1209:149 06-17-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. - Date Issued: JUNE 301 2009 Listing Expires June 30, 2010 Authorized By: FRANCIS MATEO, Program Coordinator Fire Engineering Division