Loading...
HomeMy WebLinkAbout1265 CARLSBAD VILLAGE DR; ; FA050112; Permit11/3/2020 FA050112 Permit Data City of Carlsbad Fire Alarm Permit 1265 CARLSBAD Job, Address: VILLAGE DR Permit Type: FALARM Parcel No: 1561802100 Lot #: 0 Permit No: FA050112 Status: ISSUED Applied 12/6/2005 Approved: 12/8/2005 Reference No.: Issued: 12/8/2005 PC #: Inspector: Project Title: CARLSBAD VILLAGE OFFICE BLDG FIRE ALARM MONITORING SYSTEM & INSPECTIONS Applicant: LOW VOLTAGE INTEGRATED SYSTEMS, INC. 2864 RANCHO GRANADERO CARLSBAD, CA 760-908-5883 iI'A'A 1111' CARLSBAD VILLAGE DRIVE INVESTORS L L C C/O FRANK VIOLI 1241 CARLSBAD VILLAGE DR #100 CARLSBAD CA L Fees ($) Add'l Fees ($) Total ($) Balance ($) 115 0 115 0 1/1 SPRINKLER MONITORIDIALER SYSTEM SUBMITTAL FIRE ALARM • SOUND • DATA • MEDIA 9 SECURITY* CCTV ACCESS CONTROL PROJECT CARLSBAD VILLAGE OFFICE BUILDING-REMAX 1265 CARLSBAD VILLAGE DRIVE CARLSBAD, CA 92008 CITY OF CARLSBAD FIRE DEPARTMENT APPROVED Subject to field inspection and required tests, notations hereon, Conditions in Correspondence and conformance with applicable regulations. The stamping of these plans shall not be held to permit or app%Z the violation of any law By Date" ate ________ LOW VOLTAGE INTEGRATED SYSTEMS, INC. 2864 RANCHO GANADERO CARLSBAD, CA 92009 (760) 908-5883 Phone (760) 929-8748 Fax Iowvoltage.sd(ãsbcglobaI.net License: B, CIO, C16 # 791832 1• FILE Y (R <~> S1869 APPROVED MEA 307 99 EVol II 7165-0694:219 (7100) 7300-0694:231 (LCD-7100) 7300-0694:241 (LDM-7 100) An ISO 9001 Compan Specifications are provided for information only. and are not intended to be used for installation purposes and are believed to be accurata Howeverno responsibility is assumed by Fire Control Instruments for their use. Specifications subject to change without notice. (D 2002 All Rights Reserved 9020-04661VER.2.3 Page I of S .[ZF'IRE CONTROL INSTRUMENTS Building Intelligent Networks 7100 SERIES www.firecontrolinstruments.com DESCRIPTION The FCI 7100 series fire alarm control panel is a multiprocessor-based,analog addressable system in a compact, yet expandable, plat- form. Intended for commercial, industrial and institutional installations, it is ideal for life safety and property protection applications. The basic 7100 series control panel pro- vides two analog addressable signaling line circuits (SLCs). Each SLC supports up to 99 analog addressable sensors, as well as up to 99 addressable monitor modules and/or con- trol points.With 198 addresses available on each SLC, total system capacity reaches 396 add resses.The 7100 uses an advanced pro- tocol that ensures an almost instant response to events while at the same time suppressing nuisance alarms. The system may be programmed with ei- ther theWindc,ws-based Field Configuration Program (FCP-7 100) or through a compre- hensive set of intuitive, securely password protected front-panel programming options. This important feature allows the system to quickly adapt to any future requirements brought on by changes in occupancies, build- ing remodels, or other contingencies. The sophisticated circuitry and powerful analog software enables the 7100 series fire alarm control panel to read the specific sen- sitivity level of each sensor and compensate for any changes due to age, dust accumula- tion or other environmental factors.The 7100 incorporates the FCI Listed Integrated SensitivityTesting (LIST) which meets NFB 72 sensitivity testing and maintenance re- quirementsThe LIST testing allows substan- tial savings in both maintenance and service while virtually eliminating nuisance alarms. The Model 7100-2D features an integral DigitalAlarm CommunicatorTransmitter (ICT) with all popular transmission formats and a 16-digit telephone number field. It is 8- digit Carrier Information Code (CIC) compli- ant and also prevents "d ialer- ru naw ay" in the event of intermittent system faultsThe 7100- 2D is UL Listed for Remote Station, Propri- etary, and Central Station fire alarm systems. The 7100 is housed in an attractive, con- temporary styled cabinet. It allows ample space for wiring and room for batteries up to 7A/H capacity. FEATURES Integral DigitalAlarm Communicator (with the 7100-2D) 120 or 240 VA C (optional) Input Line Voltage Intuitive Front Panel Programming 80-characterAlpha-numeric Display Two Style 4 (Class "B") Signaling Line Circuits. Style 6 (Class "A") with optional CAOM module Two Style (Class "B") Regulated Notification Appliance Circuits rated for l.5A mp. each. Style Z (Class"A") with optional CAOM module Suitable for Pre-Action Deluge applications with optional MCOM module Available with Plastic or Metal Door Periodic Trouble Reminder Individual Sensor Drift Compensation Listed Integral SensitivityTesting (LIST) Dual-stage Maintenance alerts ("Dirty" and" Very Dirty") Multilevel Sensor Sensitivity Adjustments (Front Panel programmable) Day/Night SensitivityAdjustments (Front Panel programmable) Alarm Verification per Individual Sensor PositiveAlarm Sequence for Sensors or Monitor Modules Four Levels of SystemAccess using Six Digit Passwords with up to Five User Passwords per Level Duplicate and ExtraA ddress indications *March Time (60 or 120 BPM)/Temporal Pattern! Coded Fours/California Code! User-Defined Zone Coding Cross Zoning 'System Configuration Programming and 500 Event Log stored in Non-Volatile Memory Fan Restart with Sequential Restart Delay Upload! Download of Panel Configuration between Panel and FCP-7 100 program (Password Protected feature) Up to 64 7100 panels in NetSOLO® network with optional WI-7 100 module COMF3RCTANALOG ADDRESSABLE FIRE CONTROL PANEL A Honeywell Company FIRE CONTROL .. INSTRUMENTSU31 1100 SERIES Building Intelligent Networks wwwfirecontrolinstruments.com OPTIONAL ACCESSORIES LCD-7 100 The LCD-7 100 remote serial display offers an 80-char- acter alphanumeric readout for remote display of all sys- tem events. It duplicates all the information on the 7100 series panel display and provides key switch protected func- tions such as System ResetAlarmAcknowledge,Trouble Acknowledge, Signal Silence, and DrillTest. LEDs on the LCD-7100 indicateAlarm, Supervisory, Sys- temTrouble, Fkwer Fault,Systems Silenced, NAC# I ,and N AC#2 Silenced conditions. The LCD-7 100 can be surface or semi-flush mounted on a standard four-gang electrical box and it can be in- stalled up to 4,000 feet (1,219 m) from the main control panel.The 7100 series fire alarm control panel can sup- port up to five (5) remote LCD-71 00 annunciators using one pair of twisted, non-shielded I 8AWG mi n.wire for serial communication and another pair of I 6AWG mm. for operating voltage. (Refer to 9020-0486) LDM-7 100 The LED Driver module (LDM-7 100) is designed to mount in a U.L. Listed remote annunciator and provides outputs for remote panel switches and 33 remote LEDs. Three LDM-7 100 modules may be installed in a single an- nunciator for a total of 99 LEDs per annunciator. This combination may be repeated up to five times for a total of fifteen (IS) LDM-7 100 at up to five different locations. Maximum distances of up to 4,000 feet (1,219 m) can be achieved using one pair of twisted, non-shielded wire for serial communication and another pair of straight-lay wire. for operating voltage. (Refer to 9020-0519) CAOM The Class"A" Optional module (CAOM) allows StyleY and Z (Class" B" and "A") operation for both Notification Appliance Circuits and Style 4 and 6 (Class" B" and"A") for both Signaling Line Circuit.. It also provides discon- nect switches for each signaling line circuit and a com- mon disconnect switch for both notification appliance cir- cuits. MCOM The Municipal Connection Option Module (MCOM) provides three choices of outputs. It can be configured as a Municipal Circuit (City Box) output at: 24VDC nominal voltage 0.0018 amp supervisory current 0.5 10 amp maximum alarm current 35 ohms maximum line resistance 14.5 ohms maximum trip coil resistance It may also be set to serve as a Reverse Eblarity output with a nominal voltage output of 24VDC at 0.012 amp maximum alarm and supervisory current. The third option the MCOM provides is as a releasing solenoid output rated at: 24VDC nominal voltage .0.005 amp supervisory current 0.710 amp maximum alarm current 2 ohms maximum line resistance It is suitable to be used with: *Skinner LV2LBX25 Asco T8210A107 Asco 8210G207 *Skinner 732l8BN4UNLVNOCl I 1C2 'Skinner 732 I2BN4TNLVNOC322C2 *Skinner 7l395SN2ENJlNOHl I lC2 PTRM The PrinterTransient module (PTRM) provides RS-232 Isolator/Transient protection for the 7100's RS-232 port (BSM connector J2). It is used in conjunction with a serial printer applied to the RS-232 port for permanent record keeping. INI-7 100 The Intelligent Network Interface module allows the 7100 series fire alarm control panel to become the platform of a peer-to-peer, token ring,self regenerative network comprised of up to sixty-four (64) 7100s. Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate However, no responsibility is assumed by Fire Contml Instruments for their use. Specifications subject to change without notice e2002All Rights Reserved FIRE CONTROL INSTRUMENTS 16 Southwest Park,Westwood,MA02090 USA Tel:781-471-3000 Fax:781-471-3099 www.firecontrolinstruments.com A Honeywell Company 9020 04661VER23 / Poge2of5I 0T Y'Y 6321 876543211 IZ rY 4321 4321 4321 181 182 TBO TB4 185 I]OOFIRE CONTROL INSTRUMENTS 7100 SERIES Building Intelligent Networks www.firecontrolinstruments.com [IL YrAM 0 TBR HEUTRALI GROUND LET} AUG. 60 HL 12345678 ITT TTT I U SPECIFICATIONS NOTIFICATION APPLIANCE CIRCUITS (TBI) Two SUPERVISED, REGULATED, POWER LIMITED OUTPUTS (NON-COOED) MAX, ALARM LOAD 1.5 AND PER CIRCUIT FOR USE WITH ANY LISTED APPLIANCE WV OPERATING VOLTAGE RANGE 7-26 VEC USE UI. LISTED END OF LINE RESISTOR EOL-N (476), P/N 4700-0512 TROUBLE SRT CONTACTS (182) FORM C RATED FOR 2 AMPS 0 30 USC ALARM CRY CONTACTS (TB2) FORM C RAYED FOR 2 AMPS 0 30 USC TRANSFER RELAY CONTROL )TB2) TRANSMITS LOSS OR BROWN OUT OF AC POWER TO ORBC-I BATTERY CHARGER POWER LIMITED UNSUPERVISED SIGNALING LINE CIRCUITS )TBS) 24 USC NOMINAL POWER LIMITED & SUPERVISED 60 ENDS MAX,LINE RESISTANCE 0.5 UT MAX. CAPACITANCE CAPACITY OF 99 ANALOG SENSORS AND SR ADDRESSABLE DEVICES PER CIRCUIT 24 VD EXTERNAL POWER (T94) RESETTABLE B NON-RESETTABLC UNREGULATED UNSUPERVISED .0 AMP MUD.FDWN EACH CIRCUIT/ 1.0 AMP MAX. COMBINED EARTH GROUND CONNECTION (TB4) AC INPUT (TOO) 120 VAC. 6090. 22MPG NON-POWER UNITED BATTERY CONNECTION (187) SUPERVISED 24 USC NOMINAL MAX. BUTTERY SIZE SI A/H NON-POWER LIMITED 0.6 AMP MAX. BATTERY CHARGING CURRENT TELEPHONE REQUIREMENTS )TBS) EC RINGER EQUIVALENCE NUMBER (RED) = 0.58 AC RINGER ESUISALENCE NUMBER = 1.3 COMPLIES WITH FCC FURY B Specifications Are provided for information on(y,and are not intended to be used for inscal(aCion purposes and are believed to be accurate I1qweYeri no responsibility is assumed by FIRM Control Instruments for their use. Specifications subject to change Without flOtiCa 02002A)I Rights ReseThed FIRE CONTROL INSTRUMENTS 16 Southwest P'ark,Westwood,MA02090 USA • Tel:781-471-3000 • Fax:781-471-3099 • www.firecontrolinstruments.com A Honeywell Company 9020-0466NER.2.3 / Page 1 oFIRE CONTROL INSTRUMENTS Building Intelligent Networks 1100 SERIES 0 www.firecontrolinstruments.com SPEFICAIONS Primary Input Power Output Power Non-resettable Power Resettable Power Two (2) Notification Appliance Circuits I 2OVAC, 50/60 Hz @ 2.0 amps or 240VAC, 50/60 Hz @ 1.0 amp 4 amps.@ 24VDC (total) 1.0 amp. max. 1.0 amp. max.)1.0 amp. max. from both circuits 1.0 amp. 1.5 amp. each @ 24VDC Current Supervisory 7100-2 (Two Loop) 0.065 amp. 7100-2D (Two Loop w/Dialer) 0.085 amp. LCD-71 00 0.050 amp. LDM-7 100 0.035 amp. INI-7100-UTF-FO 0.040 amp. Alarm 0.085 amp. 0.105 amp. 0.075 amp. 0.200 amp. (All LEDs lit) 0.040 amp. OperatingTemperatut Relative Humidity Battery Charger Capacity Alarm &Trouble Relay Contacts Dimensions 7100 LCD-7 100 LDM-7 100 Weight (7 100) AGENCYAPPRWALS U. L. File SI869 FM Approved CSFM 307-99-E 307-99-E Vol. II MEA 7165-0694:219 (7100) 7300-0694:231 (LCD-7100) 7300-0694:241 (LDM-7 100) 32- I20°F(0-49°C) 85 % (non-condensing) 31 A/H (Cabinet accommodates 7A/H size batteries) Form"C",2 amps.@24VDC (resistive) I6.9"Hx I4.5"Wx3"D(40x37x7.5cm) 4.25" H x 8.25"W x 1.88" D (11.5 x 20.5 x 4.6 cm) 6"W x4 I/2"W (15.24 x 11.5 cm) 241bs(II kg) Specifications are provided for information only, and are not intended to be used hr installation purposes and are belie,ed to be accurate However, no responsibility Is assumed by Fire Control Instruments for their use. Specifications subject to change without notice ©2002A11 Rights Reserved FIRE CONTROL INSTRUMENTS 16 Southwest Park,Westwood,MA02090 USA Tel:781-471-3000 Fax:781-471-3099 www.firecontrolinstruments.com A Honeywell Company 9020661VER 2.3 I Page 4 of S 0 FIRE CONTROL .Ii INSTRUMENTS 1100 SERIES Building Intelligent Networks www.firecontrolinstruments.com ORDERING INFORMATION BASIC KITS Part Number Model Description 1100-1311 BK-7100-2 Basic System Kit,2 SLC (BSM,Keypad DisplayTransformer) 1100-1312 BK-7 I 00-2D Basic System Kit w/ DACT 2 SLC 1100-1313 BK-7 I 00-2-240V Basic System Kit, 2 SLC, 24OVAC 1100-1314 BK-7 I 00-2D-240V Basic System Kit wl DACT 2 SLC,240VAC CABINETS 1100-1307 7100-ENC-PLASTIC Enclosure with Plastic Door, standard (16.9" H x 14.4" D 3" D) 1100-1308 7100-ENC-META L Enclosure with Metal Door, standard (16.9" H x 14.4" D 3" D) 1100-0480 NS-7IOOB Enclosure, NetSOLOO Broadband, black (19" H x 19"W x 4" D) 1100-0481 NS-71 OOR Enclosure, NetSOLO® Broadband, red (19" H x 19"W x 4" D) OPTIONAL MODULES 1100-0399 LCD-7 100 Remote Serial Annunciator (80-character) 1100-0428 1100-1233 LDM-7 100 C1AOM Remote LED Driver Module ClassA Option combination module with disconnect switches for both Signaling Line Circuits and NotificationAppliance Circuits 1100-1234 MCOM Municipal Connection Option Module for Local Energy City Box, Reverse Polarity Signaling, or Releasing Solenoid 1100-1235 PTRM PrinterTransient Module 1100-0440 INI-7100-UTP Intelligent Network Interface module- Unshieldedwisted Fir 100-0439 INI-7 I 00-FO Intelligent Network Interface module- Fiber Optic REPLACEMENT PARTS 1420-0429 EN-7 100 Enclosure (replacement) 120-0779 CS-71 00 Plastic Door (replacement) 120-0867 CS-7 I OOM Metal Door (replacement) 120-0778 T-71 00 Transformer, I 2OVAC input (replacement) 120-0801 T-7100-240 Transformer, 24OVAC input (replacement) 1 120-0781 BSM-2 Basic System Module, 2 SLC (replacement) 1120-0780 BSM-2D Basic System Module,2 SLC w/DCT (replacement) 120-0767 KeypadAssembly (replacement) Specifications am provided for information only, and are not intended to be used for installation purposes and ate belie,ed to be accurate. However, no responsibility is assumed by Fire Control Instruments for their use. Specifications subject to change without notice 02002A11 Rights Reserved FIRE CONTROL INSTRUMENTS 16 Southwest Park,Westwood,MA 02090 USA • Tel:781-471-3000 Fax:781-471-3099 • www.firecontrolinstruments.com A Honeywell Company 9020.66NER. 2.3 I Page5ofS FcI 0 FIRE CONTROL INSTRUMENTS by Honeywell MS-IAE MS-7 and MS-IS Description The FCI MS-7 Style manual fire alarm stations are available in a wide variety of configurations. They meet the requirement of the Americans with Dis- abilities Act (ADA) of a 5-lb. maximum pull force to activate. Operating instructions are molded into the handle along with Braille text. All stations have a key lock/reset which is keyed alike with FCI fire alarm control panels and manual fire alarm sta- tions. MS-TAF Velociti Addressable Station The MS-7AF VelocitiTM Series addressable station is a double action station designed for installation in the signaling line circuit of FCI analog address- able control panel. Activation of the station causes its assigned address to register at the control panel. The door contains an LED which flashes green in normal condition and lights steadily red when the station has been activated.* The station features screw terminals. The VeloCitiTM Series stations use a communication protocol that substantially increases the speed of communication between the sensors and certain FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than ear- lier designs. Non-Coded, Manual Fire Alarm Stations MS-7 Features Addressable stations compatible with all FCI analog addressable fire alarm controls. Conventional stations suitable for use with any UL Listed control panel. Both single and double action stations available. Tumbler lock for test and reset keyed alike with FCI controls. Surface or semi-flush mounting. Shock and vibration resistant. Stations (MS-7LOB) Listed for outdoor applications. Meets ADA pull force requirements. An ISO 9001-2000 Company SIGNALING ®MEA LISTED APPROVEt Approvec 246 3023594 E O E Vol VII L 01150 0691 26 *only the red LED is operative in panels that do not operate in VelocitilM mode. Velociti" and E3 Series' are trademarks of Fire Control Instruments. FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Fire Control Instruments for their use. @200fl Fire Control Instruments. Allnghtsreserved. www.firecontrolinstruments.com 9020-0616 Rev. A page 1 of 2 MS-7 Double Action Station . The MS-7 double action station is used with con- ventional fire alarm control panels. It features a set of single pole contacts and screw terminals for con- nection to an initiating circuit. MS-7S Single Action Station The MS-7S single action station is used with con- ventional fire alarm control panels. It features a set of single pole contacts and wire leads for connec- tion to an initiating circuit. MS-iSP Double Action Station The MS-7SP is a double action station similar to the MS-7 station, with the additional feature of both English and Spanish instructions molded into the unit. Ordering Information Model Description MS-7 Double action station. MS7AF** VelocitiTM addressable double action station. MS-7S Single action station, wire leads. MS-7SP Double action station, English and Spanish instructions. MS-71-013 Double action station, outdoor use. (Must use WBB Backbox). WBB Backbox, MS-7LOB. SBA 0 Surface backbox. BG-TR Trim ring for semi-flush mount. **For use with certain FCI analog addressable control panels only. MS-7LOB Double Action Station (Listed for Outdoor Applications) The MS-7LOB station must be mounted on a Model WBB backbox. In retrofit applications, the station is UL Listed for use with the WP-10 back- box. It is intended for use with conventional control panels and has a set of single pole contacts and screw terminals. Mounting The MS-7 interior stations may be surface mounted (use backbox SB-b) or semi-flush mounted on a standard double-gang, or 4-inch (10.2 cm) square electrical box. An optional trim ring (BG-TR) may also be used for semi-flush mounting. Specifications Material: Lexane Contact Ratings: 0.25 amp @ 30 VACNDC (resistive) Dimensions: 5 5/8" H x 4 1/4" W x 1 1/4" D (14x 10.1 x3.2cm) Operating Temperature (MS-7AF): 32o to 120 F (00 to 49 C) Relative Humidity (MS-7AF): 10 to 93% (non-condensing) Supervisory Current (MS-7AF): .0030 amp. FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel: 781-471-3000—Fax: 781-471-3099 www.firecontroIinstruments.com 9020-0616 Rev. A page 2 of 2 ------- ---- 0 FIRE CONTROL INSTRUMENTS by Honeywell Velociti"m Series ASD-PL2F and ASD-PTL2F Description The FCI VelocitiTM Series, analog addressable plug-in smoke sensors with integral communication provide features that surpass conventional sen- sors. Sensitivity can be programmed in the control panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set, providing exact locations for selective maintenance when the chamber contamination reaches an unacceptable level. The ASD-PL2F photoelectric sensor's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135°F (57°C) fixed-temperature thermal sensing on the ASD-PTL2F model. The VelocitiTM Series use a communication proto- col that substantially increases the speed of com- munication between the sensors and certain FCl analog addressable fire alarm controls. These de- vices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is a response speed up to five times greater than ear- lier designs. Ordering Information Model Description ASD-PL2F Analog, Addressable Photoelectronic Smoke Sensor ASD-PTL2F Analog, Addressable Photoelectronic Smoke Sensor Analog, Addressable Photoelectronic Smoke Sensor ASD-PL2F ASD-PTL2F Features Sleek, low-profile design. Visual rotary switch addressing. Built-in functional test switch activated by an external magnet. Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm*. Optional relay, isolator, or sounder bases. Low standby current; Analog addressable communication. Stable communication technique with noise Immunity. Optional remote, single-gang LED Indicator (RA400Z). Suitable for installation in ducts. Note: *Only the red LED is operative in panels that do not oper- ate in Velociti° mode. O Velociti'° and E3 Series' are trademarks of Fire Control Instruments. An ISO 9001-2000 Company SIGNALiI - IVEA LISTED APTh Approved S1913 3023594 219-02.EVoIVI 07272-(M:2153 FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 761-471-3000—Fax: 781-471-3099 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responsibility is assumed by Fire Control Instruments for their use. ©2005 Fire Control Instruments. All fights reserved. www.firecontroIinstruments.com 9020-0617 Rev. A page 1 of 2 Installation ASD-PL2F plug-in sensors use a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug- in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: 4.0" (10.2 cm) square box. 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. Single-gang box (except relay or isolator bases). With B501 BH or B501 BHT base, use a 4.0" (10.2 cm) square box. With B224RB or B224B1 base, use a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision pro- vided by the SLC, end-of-line resistors are not re- quired. Wiring "1-taps" or branches are permitted for Style 4 (Class 'B") wiring. Sensor Spacing FCl recommends spacing sensors in compliance with NFPA 72. In low airflow applications with smooth ceilings, space sensors 30 feet (9.1 m). For specific information regarding sensor spacing, placement and special applications, refer to NFPA 72. Specifications Size: 2.1" (5.1 cm) high x4.1" (10.4 cm) diameter installed in B501 base, 6.1' (15.5cm) diameter installed in ADB-FL base. Shipping Weight: 5.2 oz. (147 g) Operating Temperature: ASD-PL2F: 32" Fto 120" F (0" C to 49" C) ASD-PTL2F: 32" F to 100" F (0" C to 38" C) Low-temperature signal for ASD-PTL2F: at 45" F (7.22" C) +1- 10" F (5.54 C) UL-Listed Velocity Range: 0-4000 ft./min. (1,219.2 rn/mm.), suitable for installation in ducts. Relative Humidity: 10-93% (non-condensing) Thermal Ratings: Fixed-temperature setpoint 135" F (57" C) Electrical Specifications Voltage Range: 15-32 volts DC peak Standby Current: (max. avg.): 300 A @ 24 VDC (one communication every 5 seconds with LED enabled) Maximum Alarm Current: 6.5 mA @ 24 VDC (LED) lit). Bases and Options ADB-FL: 6.1" (15.5 cm) diameter B501: 4.1" (10.4 cm) diameter B5OIBH or B501 BHT: Sounder base assembly (13501 BHT produces a temporal pattern). Includes B501 base. B224RB Relay Base: Screw terminals: Up to 14 AWG (2.0mm2) Relay type: Form-C Rating: 2.OA @ 30 VDC resistive; 0.3A@ 110 VDC inductive; 1.0 A@ 30 VDC inductive. Dimensions: 6.2": (115.7 cm) x 1.2" (3.0 cm) B524B1 Isolator Dimensions: Base: 6.2" (15.7 cm) x 1.2" (3.0 cm) Maximum: 25 devices between isolator bases. ra400Z Remote alarm indicator, LED. bck-200 Black detector covers (box of 10). FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwçod, MA 02090-Tel: 781-471-3000-Fax: 781-471-3099 www.firecontrolinstruments.com 9020-0617 Rev. A page 2 of 2 MUFCi 0* FIRE CONTROL INSTRUMENTS by Honeywell Velocili"m Series ATD-L2F. ATD-HL2F and ATD-HL2F Description The FCI VelocitiTM Series, addressable plug-in ther- mal sensors with integral communication provide features that surpass conventional sensors. Point ID capability allows each sensor's address to be set, providing exact locations for pinpointing alarm locations and for selective maintenance. ATD ther- mal sensors use an innovative thermistor sensing circuit to produce 1350F/570C fixed-temperature (ATD-L2F) and rate-of-rise thermal detection (ATD- RL2F) in a low-profile package. The ATD-HL2F provides fixed high-temperature detection at 1900 F188°C. These thermal sensors provide cost effec- tive, addressable property protection in a variety of applications. The VelocitiTM Series use a communication proto- col that substantially increases the speed of com- munication between the sensors and certain FCI • analog addressable fire alarm controls. These de- vices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than ear- lier designs. Ordering Information Model Description ATD-L2F Addressable Thermal Sensor, fixed, 135 F ATD-RL2F Addressable Thermal Sensor, rate-of-rise ATD-HL2F Addressable Thermal Sensor, fixed, 190 F Addressable Thermal Sensor ATD-L2F Features Sleek, low-profile design. Visual rotary switch addressing. Built-in functional test switch activated by an external magnet. Bicolor LEDs flash green whenever the sensor is addressed, and light steady red on alarm*. Optional relay, isolator, or sounder bases. Low standby current. Addressable communication. Stable communication technique with noise immunity. Optional remote, single-gang LED accessory (RA400Z). Suitable for installation in ducts. Note: *Only the red LED is operative in panels that do not oper- ate in VelocitiTM mode. Velociti"' and E3 Series are trademarks of Fire Control Instruments, An ISO 9001-2000 Company SIGNALING @<S> MEA ' LISTED APPROVEC Approvec 1i 233 3023594 219 0 E Vol VI 07270 0691 256 FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information on,, are not intended for installation purposes, and are subject to change without notice No responsibility is assumed by Fire Control Instruments for their use. 02005 Fire Control Instruments. Allnghts reserved. www.firecontrolinstruments.com 9020-0620 Rev. A page 1 of 2 Installation ATD plug-in sensors use a separate base to sim- plify installation, service, and maintenance. A spe- cial tool allows maintenance personnel to plug-in and remove sensors without using a ladder. Mount the base on a box which is at least 1.5" (3.8 cm) deep. Suitable mounting base boxes include: ' 4.0" (10.2 cm) square box. 3.5" (8.9 cm) or 4.0" (10.2 cm) octagonal box. Single-gang box (except relay or isolator base). With 8501 BH or B501 BHT base, use a 4.0" (10.2 cm) square box. With B224RB or B224B1 base, use a 3.5" (8.9 cm) octagonal box, or a 4.0" (10.2 cm) octagonal or square box. NOTE: Because of the inherent supervision pro- vided by the SLC, end-of-line resistors are not re- quired. Wiring "T-taps" or branches are permitted for Style 4 (Class "B") wiring. Specifications Size: 2.1" (5.1 cm) high x4.1" (10.4 cm) diameter installed in B501 base, 6.1(15.5cm) diameter installed in ADB-FL base Shipping Weight: 4.8 OZ. (1137 g) Operating ATD-L2F, ATD-RL2F: Temperature: -4° F to 1000 F (-20° C to 38°C); ATD-HL2: -4° F to 150°F (-20 C.to 66°C) Sensor Spacing: UL approved for 50 ft. (15.2 m) center to center FM approved for 25 x25 ft. (7.6 x 7.6 m) spacing Relative Humidity: 10- 93% (non-condensing) Thermal Ratings: ATD-L2F: Fixed-temperature setpoint 135°F (57°C) ATD-RL2F: Rate-of-rise detection 15°F (8.3°C) per minute ATD-HL2F: High temperature heat 190°F (88°C) Electrical Specifications Voltage Range: 15 32 volts DC peak Standby Current 200 pA @ 24 VDC (max. avg.): (without communication); 300 jiA @ 24 VDC (one communication every 5 sec- onds with LED enabled) LED Current 6.5 mA @ 24 VDC ('ON"). (max.): Voltage range: 15-32 volts DC peak Bases and Options ADB-FLF: 6.1" (15.5 cm) diameter standard base B501: 4.1° (10.4 cm) diameter flangeless base B50IBH or Sounder base assembly (13501 BHT pro- B50IBHT: duces a Temporal Pattern). Includes B501 base. B224RB Screw terminals: Relay Base: Up to 14 AWG (2.0 mm2) Relay type: Form-C Rating: 2.OA @ 30 VDC resistive; 0.3 A@ 110 VDC inductive; 1.0 A@ 30 VDC inductive. Dimensions: 6.2': (15.7 an) x 1.2" (3.0 cm) B224B1 Dimensions: Isolator 6.2' (157 cm)x 1.2" (3.0 cm) Base: Maximum: 25 devices between isolator bases ra400Z Remote alarm indicator, LED bck-200 Black detector covers (box of 10) O FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090-Tel: 781-471-3000-Fax: 781-471-3099 www.firecontrolinstruments.com 9020-0620 Rev. A page 2 of 2 Velociff""" Series AMM-2F 0 FIRE CONTROL INSTRUMENTS by Honeywell n Description The FCI VelOcitiTM Series, addressable monitor module AMM-2F is a single Style B, Class B initiating device circuit (IDC) with a 47KW end-of-line resistor. This mod- ule provides an address for any device or group of de- vices connected to this circuit on the signaling line circuit (SLC) of the FCI addressable series fire alarm control panel. Any initiating device with normally open (NO.) dry contacts may be made addressable when connected to the AMM-21F module. The VelocitiTM Series use a communication protocol that substantially increases the speed of communication be- tween the sensors and certain FCI analog addressable fire alarm controls. These devices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than earlier de- signs. The AMM-21F module can be programmed to provide a wide variety of input functions to the FCI addressable series fire alarm control panels. It can be identified as a manual station, heat detector, plenum detector, water- flow switch, tamper switch, N.O. contact, smoke detector, projected beam smoke detector, sub loop, remote zone, etc. It can also serve as a remote system silence, system reset, system acknowledge or drill switch. It is even pos- sible to customize its device type to meet specific job requirements. The initiating device circuit of the AMM-2F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. The compact size facilitates the installation of the module inside manual stations, or mounting boxes of various types of alarm initiating devices. Ordering Information Model Description AMM-21F Addressable monitor module, single circuit, Style B, Class B Velocitil and E3 SeriesTm are trademarks of Fire Control Instruments. Addressable Monitor Module AMM-2F Features Compact size allows easy installation. Class B, Style B, initiating circuit. 40 Ohm line resistance for each initiating device circuit. Connects to any normally open dry contact device. Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm.* *Note: Only the red LED is operative in panels that do not oper- ate in VelocitiTM mode. Specifications Supervisory current: 0.0004 amp Alarm current: 0.0006 amp. Operating temperature: 32" to 120" F (0" to 49" C) Relative humidity: 10 to 93% (non-condensing) End-of-line Resistance: 47K ohms Dimensions: 1.3" Lx2.5"Wx0.5" D (3.3x5.5x 1.3 cm) An ISO 9001-2000 Company SIGNALING L <S> M EA & LISTED APPROVE( Approvec 51945 3023594 227 01 E Vol IV 07300 0691 178 FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information only, are not intended for installation purposes, and are subject to change without notice. No responebility is assumed by Fire Control Instruments for their use. @2005 Fire Control Instruments All nghts reserved. www.firecontrolinstruments.com 9020-0626 Rev. A page 1 of 1 Specifications Supervisory current: Alarm current: Operating temperature: Relative humidity: Dimensions: End-of-Line Resistance: 0.0075 amp. 0.00475 amp. 32' to 120 F (0 to 49 C) 10 to 93% (non-condensing) 1.3" H x 2.5"W x 0.5" D (3.3x5.5x 1.3 cm) 47 K ohms An ISO 9001-2000 Company SIGNALING MEA (b-) LISTED APPROVE[ Approvec L-.-.....P 1940 3023594 22701 E Vol IV 01300 069L 232 IRE CONTROL INSTRUMENTS by Honeywell Velocill"m Series AMM-21F Description The FCI VelocitiTM Series, addressable dual moni- tor module, AMM-21F, features two (2), Style B, Class B initiating circuits, each with end-of-line re- sistor. This module provides addresses for any de- vice or group of devices connected to each circuit. Any alarm initiating devices with normally open (NO.) dry contacts, such as heat detectors, pro- jected beam smoke detectors, 4-wire smoke detec- tors, water flow switches, tamper switches, manual stations, etc. may be installed in these circuits. The VelocitiTM Series use a communication proto- col that substantially increases the speed of com- munication between the sensors and certain FCI analog addressable fire alarm controls. These de- vices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than ear- lier designs. The first circuit address is set via a rotary switch. The second circuit is automatically assigned the next higher address. The module has a single panel-controlled red LED. Addressable Dual Monitor Module Features Compact size allows easy installation. Class B, Style B, initiating circuits. 40 ohm line resistance for each initiating circuit. Accommodates any normally open contact device. Bicolor LEDs flash green whenever the module is addressed, and light steady red on alarm.* *Note: Only the red LED is operative in panels that do not oper- ate in VelocitiTM mode. The AMM-21F module is designed for installation in the signaling line circuit of any FCI addressable control panel. The AMM-21F is designed to mount in a 4" square junction box, 2 1/8" deep. The initiat- ing device circuit of the AMM-21F can support a maximum line resistance of up to 40 ohms allowing the use of linear heat detection devices. Ordering Information Model Description AMM-21F Monitor module, two circuit, Style B, Class B Velociti' and E3 Series' are trademarks of Fire Control Instruments. FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information only, are not intended for installation purposes, and era subject to change without notice. No responsibility is assumed by Fire Control Instruments for their use. @2005 Fire Control Instruments. All rights reserved. www.firecontrolinstruments.com 9020-0629 Rev. A page 1 of 1 1 FIRE CONTROL INSTRUMENTS by Honeywell Velocili"m Series AOM-2RF Description The FCI VelocitiTM Series, addressable output relay control module (AOM-2RF) allows an FCI analog addressable fire alarm control to switch discrete relay contacts by code command. The relay provides two (2), isolated sets of Form-C contacts which transfer simultaneously. Circuit connections to the relay contacts are not super- vised by the module. The VelocitiTM Series use a communication proto- col that substantially increases the speed of com- munication between the sensors and certain FCI analog addressable fire alarm controls. These de- vices operate in a grouped fashion. If one of the devices in the group has a status change, the panel's microprocessor stops the group poll and concentrates on the single device. The net effect is response speed up to five times greater than ear- lier designs. The AOM-2RF Module is designed for installation in the signaling line circuit of any FCI analog ad- dressable fire control panel. The module contains a panel controlled LED. The AOM-2RF is de- signed to mount in a 4" square junction box 2 1/8" deep. Note: Only the red LED is operative in pan- els that do not operate in VelocitiTM mode. Relay Contact Ratings Current Maximum Load Rating Voltage Description Application 3A 30 VDC Resistive Non-Coded 2A 30 VDC Resistive Coded 0.9A 110 VDC Resistive Non-Coded 0.5A 125 VAC Resistive Non-Coded 0.5A 30 VDC Inductive Coded (LJR5ms) 1A 30 VDC Inductive Coded (UR2ms) 0.5A 125 VAC Inductive Non-Coded (PF.35) 0.7A 75 VAC Inductive Non-Coded VelocitiTh and E3 SeriesTvl are trademarks of Fire Control Instruments Addressable Output Relay Control Module AOM-2RF Features Two (2) sets of Form "C" contacts. Compact size allows easy installation. Specifications Supervisory Current: .00030 amp Alarm Current: .00030 amp. Operating Temperature: 3T to 120 F (0" to 49 C) Relative Humidity: 10 to 93% relative humidity (non-condensing) Dimensions: 4 1/2" H x 4" W x 1 1/4" (3.3x5.5x 1.3 cm) Ordering Information Model Description AOM-2RF Addressable output relay control module An ISO 9001-2000 Company SIGNALING MEA LISTED APPROVEE Approvec 1941 3023594 227 Ot EVol Pd 075iu 069L 178 FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090—Tel 781-471-3000—Fax: 781-471-3099 Specifications are for information only, are not intended for installation purposes, and are subject to change wdhout notice. No responsibility is assumed by Fire Control Instruments for their use. @2005 Fire Control Instruments. All nights reserved. www.firecontroIinstruments.com 9020-0625 Rev. A page 1 of 1 Series AS Series AH (R II <a> APPROVED DESCRIPTION Wheelock AS/AH Series SINGLE & MULTI-CANDELA AS Series AUDIBLE STROBE & AH Series AUDIBLE APPLIANCES FIRE CONTROL INSTRUMENTS BugB.enbNeLwocs www.firecontrolinstruments.com O The 2-wire Wheelock AS Series audible/ visual and AH Series audible notification appliances offer many features with low current draws. Strobe options for wall mounted models include 15/75 cd or field-selectable Multi- Candela strobes that may be set to 15, 30, 75, or 110 cd. Ceiling mounted models incorporate field-selectable strobe settings of 15, 30, 75, or 95 cd. The audible notification appliances pro- vide a field-selectable choice of either a con- tinuous horn tone or temporal pattern (per ANSI S3.4 1)when constant voltage is sup- plied by the notification appliance circuit. Each tone has three dBA settings to choose from. Additionally, the audible tone may be silenced while maintaining strobe activation. All models may be synchronized when used in conjunction with the Wheelock SM and DSM Sync Modules. Synchronization of the continuous horn tone provides the temporal pattern man- dated by NFPA 72 for fire evacuation sig- naling. This ensures a clearly distinguish- able temporal pattern when two or more audible devices are within hearing distance. If not synchronized, the temporal patterns may overlap. At the same time, the strobes will also be synchronized. This provides compliance with ADA recommendations regarding photosensitive epilepsy and NFPA and UFC standards when installing two or more visual appliances within a com- mon field of view. Only two wires are required, to achieve these sequences of operation. Separate cir- cuits for audible and visual devices are not necessary. FEATURES Approvals include: - UL Standard 1971 - UL Standard464 - New York City (MEA) - California State Fire Marshal (CSFM) - Factory Mutual (FM) ADA/NFPA/UFC/ANSI Compliant Wall Mounted Models are available with Field Selectable Multi-Candela Settings of 15, 30, 75, or 110 cd Ceiling Mounted Models are available with Field Selectable Multi-Candela Settings of 15, 30, 75, or 95 cd Single Candela Models are available in 15/75 cd Weatherproof Models are available for Outdoor Use (ASWP) Selectable Continuous Horn or Temporal Pattern (ANSI 3.41) Three Field Selectable dBA Settings at 90, 95, or 99 dBA for both Tones Silenceable Horns and Non- Silenceable Strobes over the Same Two Wires Strobes flash once per second over the Regulated Voltage Range 12 & 24 VDC Models with Wide UL "Regulated Voltage Range" using Filtered DC or Unfiltered FWR Input Voltage Synchronize with SM or DSM Sychronization Modules Fast Installation with IN/OUT Screw Terminals using 12 to 18 AWG Wires Iva - Multi-Candela Indicator (bottom of lens) An ISO 9001 ComDan Specifications are provided for information only, and are not intendedto be used for installation purposes and are believed lobe accurate. However, no responsibility is assumed by Fire Control Instruments for their use. Specifications subjecttochangewthout notice. 02003 All Rights Reserved 9020.0572lVer. 1.0 Page 1 of 4 A Honeywell Company 0 1 8 Wheelock 771FIRE CONTROL INSTRUMENTS AS/AN Series Buiiig YentNetwocs General Notes Strobes are designed to flash at one flash per second minimum over the Regulated Voltage Range. Note that NFPA-72 (1999) specifies a flash rate of one to two flashes per second and ADA guidelines specify a flash rate of one to three flashes per second. All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. Series AS strobe products are listed under UL Standard 1971 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C) and maximum humidity of 93% (± 2%). Series AH Horns are Listed under UL Standard 464 for audible signal appliances (indoor use only). Series AH-24WP audible appliances are Listed under UL Standard 464 for indoor/outdoor use with a temperature range of -31°F to 150°F (-35°C to 66°C) and a maximum humidity of 95%. Regulated Voltage Range' is the newest terminology used by UL to identify the voltage range. Prior to this, UL used the term "Listed Voltage Range". fl Table 1RatthgaperUL 1971 N oo. 1.rur Vom3oz VDC Reanratea VOLTAGE Reaoa VDC,9W R Sraoor (3omea (or) PS244N 24 160-331) 5,130/15,130 515983585 -[FZ 24 160 -330 15 (15 or A) ;&1215-?:W -M 32 8D-17S 15 95.1w 23 160-330 ]5/30/35,27 28 360 -330 7535 -31°F 15b 2 Aveage PM S Cunt 9rAS-24 N (38 W odela each Cmdeh Setting Aveeage C'28315ntw 991 Hh dBA Setting (99 6158) Vo]torge 154 30o9 75rr8 110 0335 03(35 0329 0303 2401.133 0073 0.114 01157 0397 3301.133 0127 0169 03138 0184 AveGage Cuneatwti Methear 6358 Setting (95 dEA) 161DILC 0078 0316 03(13 035 240NDC 0645 OBBB 0333 0179 330\01 0(15 0(178 0107 0134 AveoSge Currentw99i ba 658 Setting (90 aBA) 1601.133 0030 0111 0281 0279 2401.133 0(012 01177 0115 0138 3301133 0006 0073 He 0121 Tab 5:dBA Ratilge 99r12VDC & 24VDC SeorIEOAS/AM 12 & 24V0C Horns Derrreorr Voroors Rsvepoeparrr PEA PEN UL 464 49 10 — Arrroror nBA 49 10 or. 09qj Hm Fb 91 27 M23IN 84 27 Oar 83 33 R— 87 84 MOOUO 84 34 ION 79 33 Table 6rAveeage EMS 021t° 9erAS-24 MCC CeibrgNode24@ each Cznde3aSetthg Average Qiaentw3h Hh 6158 Setting (99 6158) Voltage 15 ad 30 ad 75a9 95 C 160162 01376 01.45 0228 0314 2401133 0037 0121 0161 03(2 3301127 0301 0113 0139 0115 Avesage arnentwithNediim 62(8 Seog (95 658) 3601.62 0070 0134 062 0307 2001.127 0019 0844 01.45 0134 330162 0018 0073 0114 0145 Aveeage Cuntw9h he 6BA Setting (90 aBA) 1601127 01176 - 0121 062 0307 2401.127 013(9 0074 0338 0127 3301.03 0009 0018 0103 0332 Table 3 Aveorge Mean Cuoreut" Serbs AB-24R24( & 85-12-8248 & W P (Romon4') Voltage Hr Mediar Lear 3601.03 03(15 0020 014 2403133 Offio 0038 0157 3301(33 0069 0001 007. 801.07 0073 03(37 0015 320162 0169 0049 0035 1753(33 0138 0- 0012 Ebb 4rAvareg0 ENS Qrt 1579.241575 Volege a48r Media tar 060'.12 0230 023.4 0015 240'12 0207 000 0007 3303(07 0215 0007 000 Ebb 7rA'07s6rNeGn (1rt EO32S-240573 VOIE4* H45 Media tree 7 80112 031 02 5 038 020012 024 0207 01,6 1751107 G335 0236 033) *Average RMS Current is per UL average method and Average Mean Current is per UL average mean method. For rated inrush and peak current across the UL Listed voltage range for both filtered DC and unfiltered VRMS (FWR), see installation instructions 0 FIRE CONTROL .Ii HIINSTRUMENTS Buigrn11entNeboz*s Wheelock AVAN Series S~mc Model OtherQ,de I bPUtVoge f1DC) I Meau Qmt e 24V5C 074 24 0024 Wiring Diagrams 59ME-S AS APM-11ANCES 14 # SM Sync Module is rated for 3.0 amps @ 24 VOC DSM Sync Module is rated for 3.0 amps per circuit. The maximum number of interconnected DSM Modulesis 20. SERIES S APPR&NES SYCHROP may I)SJ fuF CLA ' PJAC CRCUtT ' SEtE FU}4 *iL) Iti,A F IA 8EiJE5 AS APPLIANCES SVCHROrIZW W/ MULTIPLE OSM tocuL:s 7 _ r.,rit ----i SERU1S AS & RS$ APPUANCES SvNCHRN?rrWi' P$4244 fl Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments for their use. Specifications subject to change without notice 02003 All Rights Reserved FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090 USA • Tel: 781-471-3000 • Fax: 781-471-3099 • www.firecontrolinstruments.com A Honeywell Company 9020-0572Ner.10/Paae3of4 FIRE CONTROL INSTRUMENTS EH3BuMjhg In bel%rentK etwo±s Wheelock AS/AH Series Architects and Engineers Specifications The notification appliances shall be Wheelock Series AS audible/strobe appliances and Series AN audible appliances or approved equals. The Series AS appliance shall be listed under UL Standard 1971 (Emergency Devices for the Hearing Impaired) for indoor Fire Protection Service. The Series AH Audible shall be UL Listed under Standard 464 (Fire Protective Signaling). Both shall meet the requirements of FCC Part 15 Class B. All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a fire alarm control panel (FACP). The audible portion of the appliance shall have a minimum of three (3) field selectable settings for dBA levels and shall have a choice of continuous or temporal pattern audible output. The strobe portion of the appliance shall produce a flash rate of one (1) flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexanre lens. The series AS shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have a minimum of four (4) field selectable settings and shall be rated per UL Standard 1971 at: 15, 30, 75, and 110 candela forwall mount, or 15, 30, 75, and 95 candela forceiling mount. The selector switch for selecting the candela shall be tamper resistant and not accessible from the front of the appliance. The 15/75 candela strobe shall be specified when 15 cd UL Standard 1971 Listing with 75 cd on-axis is required (e.g. ADA compliance). When synchronization is required, the appliance shall be compatible with Wheelock's SM and DSM Sync Modules. The strobes shall not drift out of synchronization at any time during operation. If the sync module fails to operate, i.e. contacts remain closed), the strobe shall revert to a non-synchronized flash-rate. The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation, The Series AS audible/strobe and Series AH audible shall incorporate a patented universal mounting plate that shall allow mounting on a single-gang, double-gang, 4-inch square, 100 mm European type backbox, or the SHBB surface backbox. If required, an NATP (Notification Appliance Trimplate) shall be provided. All notification appliances shall be backward compatible. Specifications and Ordering Information Model Oer Code Sthbe Candela Non-Sync Sync w,4 orD4 24 VDC 12 VDC W an Mount Ceithg Mount UL MEP CSFM FM BW AS-24NCW -FR 9024 15,00/15410 X X X - X - X X X X X AS-24MCW 4W 9025 15,00/15410 X X X - X - X X X X X AS-241575W -FR 7405 15 (75 on Ax) X X X - X - X X X X X AS-121575W -FR 7410 15 (75 on Ax) X X - X X - X X X X X AS-2404CC-FW 3162 15,00/15,05 X X X - - X X * * * * AS'J P-2475W -FR 9012 75th -311F X X X - X - X X X X * AH-24-R 7892 - X X X - X X X X X X X AH-12-R 7891 - X X - X X X X X X X X AH-24W PR 7416 - X X X - X X X X AH-12W P-R 7415 - X X - X X X X X Specifications are provided forinformation only, and are not intended to be used forinstallation purposes and are believed to be accurate. * PENDING However, no responsibility is assumed by Fire Control Instruments for their use. Specifications subject to change without notice. ©2003 AJI Rights Reserved FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090 USA • Tel: 781-471-3000 • Fax: 781-471-3099 • www.firecontrolinstruments.com A Honeywell Company 9020-0572Ner. 1.0/ Page 4ot4.) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM • LISTING SERVICE LISTING No. 7165-0694:219 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Fire Control Instruments, *16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Models 7100-1, 7100-2, 7100-11D and 7100-2D fire alarm control units. Power-limited; non-coded, manual, automatic, local, auxiliary, central station, remote station, proprietary service, releasing device service, waterfiow and sprinkler supervisory service. Refer to listees data sheet for additional detailed product description and operational considerations. System components: BSM-1 1120-0783 Basic System Module BSM-2 1120-0781 Basic System Module BSM-1D 1120-0782 Basic System Module with DACT BSD-2D 1120-0780 Basic System Module with DACT CAOM 1120-0763 Class A Option Module MCOM 1120-0761 Municipal Module PTRM 1120-0762 Printer Module 7100-EN-M-Door 1120-0779 Metal Door 7100-EN-Back Box 1120-0787 Back Box 7100-EN 1120-0787 Enclosure 7100-TXA 1120-0778 Transformer Assembly 7100-EN-P-Door 1120-0779 Plastic Door . 7100-TXA-240 1120-0801 240V Transformer Assembly INI-7100 INI-7100-UTP/-FO Intelligent Network Interface INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Inc. Label APPROVAL: Listed as fire alarm control units for use with separately listed electrically compatible initiating and indicating devices. These control units can generate the temporal code pattern fire alarm signal as required per NFPA 72, 1999 Edition. Refer to listee's Installation Instructions Manual for details. NOTE: For Fire Alarm Verification Feature (delay of fire alarm), the maximum Retard/Rest/Restart period shall not exceed 30 seconds. *Rev. 02-05-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date issued: MAY 23, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM • LISTING SERVICE LISTING No. 7150-0694:236 Page 1 of 1 CATEGORY: Boxes/Pull Stations LISTEE: Fire Control Instruments, *16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Models MS-75, MS-71-0B, MS-7, MS-7A and MS-75P fire alarm pull boxes. The MS-7 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. XLF: 7150-0028:199 *Rev. 02-05-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 23, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-0694:254 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Fire Control Instruments, *16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Models ASD-PL2 and ASD-PTL2 photoelectric smoke detector. Model MCS-ACCLIMATE2 employs a 1350F supplemental integral heat sensor which only assists in a fire situation. This thermal circuitry is NOT approved for use in lieu of a required heat detector. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors when used in conjunction with listee's separately listed compatible fire alarm control units and bases. Suitable for open areas with air velocity between 0-4000 fpm. Models ASD-PL2, ASD-PTL2, AND MCS-ACCLIMATE2 are also suitable for installation inside ducts with a maximum air velocity of 4000 fpm. NOTE: The photoelectric type detectors are generally more effective at detecting slow, smoldering fires which smolder for hours before bursting into flame. Sources of these fires may include cigarettes burning in couches or bedding. The ionization type detectors are generally more effective at detecting fast, flaming fires that consume combustible materials rapidly and spread quickly. Sources of these fires may include paper burning in a waste container or a grease fire in the kitchen. XLF: 7272-1209:160 *Rev. 02-05-2004KK This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 23, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7270-0694:256 Page 1 of I CATEGORY: Heat Detector LISTEE: Fire Control Instruments, 16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Models ATD-1-2, *ATD1-2F, ATD-HL2 AND *ATD..HL2F (fixed temperature) and ATD- RL2, *ATD.RL2F (fixed temperature with Rate-of-Rise) electronic heat detectors. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: ATD-1-2, *..L2F ATD-RL2, *RL2F = 1350 F fixed temperature ATD-HL2, *..HL2F = 1900 F fixed temperature INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings, and UL Label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. XLF: 7270-1653:137 *Rev. 08-25-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: AUGUST 25, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM • LISTING SERVICE LISTING No. 7300-0694:178 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Fire Control Instruments, 16 Southwest Park, Westwood MA 02090 Contact: Anthony J. Shalna (781) 471-3000 FAX (781) 471-3099 DESIGN: Models AMM-4, *AMM4F AMM-2 and *AMM2F monitor modules and Models AOM, AOM- 2, AOM-2R, *AOM..2RF AOM-2S and *AOM..2SF control modules. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model designation, electrical rating and UL label. APPROVAL: Listed as accessories for use with separately listed compatible control units. System Sensor Model SMB500 surface mount box (CSFM Listing No. 7300-1653:103) may be used as an enclosure for these modules XLF: 7300-1653:103 Rev 09-07-2005 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: SEPTEMBER 7, 2005 Listing Expires June 30, 2006 is Authorized By: DIANE K. AREND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0785:131 Page 1 of 2 CATEGORY: Fire Alarm Devices for the Hearing-Impaired LISTEE: Wheelock Inc., 273 Branchport Avenue, Long Branch, NJ 07740 Contact: Luy Nguyen (732) 222-6880 Fax (732) 222-5607 DESIGN: Models AS-1215, -2415, -1230, -2430, -121575, -241575, -2475 and -24110 audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. Models AS-1215W, -2415W, -1230W, -2430W, -121575W, -241575W, -2475W and -24110W audible/strobes for the hearing impaired followed by any three alpha/numeric characters indicating lens orientation, lettering and color. These units with suffix -W are for wall mount only. Models AS-2415C, -2430C, -2475C and -24100C audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering, orientation and color. These units are intended for ceiling mount only. Model AH-12, -24, AH-12WP, -24WP audible appliances (no strobe), followed by an alpha or numeric character indicating product color. Model.AS-24MCW and AS-24MCC audible/strobe, followed by any two alpha or numeric character indicating lettering and product color. Model ASWP-2475W audible/strobe with integral private mode fire/emergency visual signaling for non-hearing impaired applications. Model ASWP*2475W is also suitable for outdoor use when mounted to Model WPBB back box. Models AS-24MCWH and AS-24MCCH audible/strobes for the hearing impaired followed by two alpha/numeric characters indicating lens lettering and product color. Units with suffix C are for ceiling mount only. Units with suffix W are for wall mount only. Refer to the listee's data sheet for detailed product description and operational considerations. RATING: Electrical: 8-17.5/16-33 VDCNFR Candela: 15:15cd, 1575:15/75cd, 30:30cd, 75:75cd, 95:95cd, 100:100cd, 110:11Ocd :MCW: Selectable 15cd, 30cd, 75cd, 110cd MCC: Selectable 15cd, 30cd, 75cd, 95cd MCWH: Selectable 135cd, 185cd MCCH: Selectable llscd, 177cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. Models ASWP-2475W and AS- 24MCW are for wall mount only. Models with suffix -W are for wall mount only. Models with suffix -C are for ceiling mount only. • *Corrected 08-20-04 Listing No. 7125-0785:131 Page 2 of 2 MARKING: Listee's name, model number, electrical/candela rating, and UL label. APPROVAL: Listed as audible and audible/visual signaling devices suitable for the hearing impaired when used in conjunction with separately listed electrically compatible fire alarm control units. For indoor use only except Models AH-12WP and AH-24WP audible appliances are suitable for indoor/outdoor. For synchronization, Models AS Series must be used with Model SM-12/24, SMX-12/24, DSM- 12/24 or DSMX-12/24 sync control module (CSFM Listing No. 7300-0785:132). Refer to listee's Installation Instruction Manual for details. These appliances can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: Models ASWP-2475W, AH-12, AH-24, -12WP and -24WP audible devices are not suitable for the hearing impaired applications. *Corrected 08-20-04 o This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 21, 2005 Listing Expires June 30, 2006 Authorized By: DIANE K. AREND, Senior Deputy 0 Program Manager