HomeMy WebLinkAbout2005 CASSIA RD; BLDG 1; AS060239; Permit11/3/2020 AS060239 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2005 CASSIA RD Permit Type: SPRINK Parcel No: 2150202700 Lot #: 0 Reference No.: Permit No: AS060239 Status: ISSUED Applied 10/3/2006 Approved: Issued: PC #: Inspector: Project Title: CASSIA HEIGHTS APTS, BLDG 1 FIRE SPRINKLER INSPECTIONS Applicant: Owner: CITY OF CARLSBAD CALIFORNIA STATE ASSESSED Fees ($) - Add'I Fees ($) Total ($) Balance ($) 180 0 180 0 1/1 LIFEGUARD APPROVED 04) .APPROVED AS NOTED E NOT APPROVED, RESUBMIT CHE(SC S ON'( FOR cOroAN T}f. DiFG CCCFi THE P3EC 1 ED CCE FFC DF ETE E M THE CDC'JCT (:TCDTO S CFONSit_E C CNHRMED AND' .!TLO PT THE 105 !E AU FOR c or NMION OE JH CF PILL TRAO. RE PROTECTION, INC. LIFEGUARD FIRE PROTECTION 2605 TEMPLE HEIGHTS DRIVE SUITE "F" OCEANSIDE, CA 92056 760-806-9997 A6o6'C>z31 Job Name : CASSIA HIEGHTS APARTMENTS Building COMMON Location : COMMON BUILDING UPRIGHTS 2.cx5 CASSIA- fQ0 System Contract Data File COMMON.UPS.WXF LIFEGUARD FIRE PROTECTION Page CASSIA HIEGHTS APARTMENTS Date 9-27-06 Hydraulic Design Information Sheet Name - CASSIA HIEGHTS APARTMENTS Date - 9-27-06 Location - COMMON BUILDING UPRIGHTS Building - COMMON System No. - Contractor - LIFEGUARD FIRE PROTECTION INC. Contract No. - Calculated By - JEREMIAH BALCH Drawing No. - Construction: (X) Combustible ( ) Non-Combustible Ceiling Height - Occupancy - B/A3 S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E H Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make RELIABLE D Area Per Sprinkler - 130 MAX ( ) Dry Model F1FR E Elevation at Highest Outlet - 17-6 ( ) Deluge Size 1/2" S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 100 N Note CALC.'D PER NFPA 13, 1999 EDITION, SECTION 7-2.3.2.4 & 7-2.3.2.5 Calculation Flow Required - 284.93 Press Required - 43.80 @ BR4 Summary C-Factor Used: Overhead Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 8-3-06 Cap. - T Time of Test - 8:40 am Rated Cap.- Elev.- E Static Press - 90 @ Press - R Residual Press - 84 Elev. - Well Flow - 1244 Proof Flow S Elevation - U P Location - HYDRANTS LOCATED ON CASSIA HIEGHTS JOB SITE P (SEE SITE PLAN) L Source of Information - BILL MARSH AND DARIEN MORAN @ LIFEGUARD FIRE Y C Commodity Class Location O Storage Mt. Area Aisle W. H Storage Method: Solid Piled % Palletized Rack M Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row C ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Water Supply Curve (C) LIFEGUARD FIRE PROTECTION CASSIA HIEGHTS APARTMENTS Page 2 Date 9-27-06 City Water Supply: Cl - Static Pressure : 81 C2 -Residual Pressure: 75.6 C2 - Residual Flow : 1244 150 140 P 120 R 110 E 100 S90 S80 U 70 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW (N "1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 - Dl - Elevation : 5.700 D2 - System Flow : 284.931 D2 - System Pressure : 58.815 Hose (Adj City) Hose ( Demand) : 100 D3 - System Demand : 384.931 Safe y Margin : 21.568 - - - - 130 - Cl - ___ - - -.---- 2 t 32 l.l1_.I I I I I I-low uiagram LIFEUARD FIRE PROTECTION Page 3 CASSIA HIEGHTS APARTMENTS Date 9-27-06 14.8 I i-A t I 14.8 15. 2 i-B 14.8 46 A i-B i-3 4-4 i-C 301 63.3 17.8 5 i-C i-D 80.9 22 8 i-B 18.3 7 i-F 18.6 8 i-F i-G t 36.9 36.f 56.5 19c 9 i-G i-H 56.5 16.3 lOi- I i-J T 163' I 16. 329 16,T I 11i-J i-K C 32.9 I 32.f 50.1 17.1 I 12 i-K i-4. 50.1 17.1 13 i-M i-N C 17t I 17.1 34.6 17.f 1 14i-N i-O C 34.6 344 52.5 174 I 16 +-0 i-P 52.6 I 262 23 I I8i-Q i-R 23 80.9 159.4 262 284.9 3849 0 i-B i-H i-L i-P i-P i-TRi-BR4i-UG6i-SRC2 103 209.5 284.9 284.9 Fittings Used Summary LIFEGUARD FIRE PROTECTION Page 4 CASSIA HIEGHTS APARTMENTS Date 9-27-06 Fitting Legend Abbrev. Name % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 I 1 1 2 2 3 4 5 6 7 8 10 II l T 90 Flow lhruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 12 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zwd Watts 709DCDA Fitting generates a Fixed Loss Based on Flow Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 rressure I I-low summary - ; ANUAKU LIFEGUARD FIRE PROTECTION Page 5 CASSIA HIEGHTS APARTMENTS Date 9-27-06 Node No, Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. 1 10.16 5.6 7.0 na 14.82 .10 80 7.0 2 10.16 5.6 7.46 na 15.29 .10 80 7.0 A 10.16 7.21 na B 10.16 7.47 na 3 10.16 5.6 8.08 na 15.92 .10 90 7.0 4 10.16 5.6 9.53 na 17.29 .10 90 7.0 5 10.16 5.6 9.89 na 17.61 .10 90 7.0 C 10.16 10.49 na 6 9.67 5.6 15.49 na 22.04 .10 90 7.0 7 10.08 5.6 10.72 na 18.34 .10 74 7.0 8 10.08 5.6 10.99 na 18.57 .10 74 7.0 F 10.08 11.8 na 9 10.08 5.6 12.19 na 19.55 .10 126 7.0 O 10.08 12.92 na 10 17.0 5.6 8.46 na 16.28 .10 114.750 7.0 I 17.5 8.57 na 11 17.0 5.6 8.85 na 16.66 .10 114.750 7.0 J 17.5 8.83 na 12 17.0 5.6 9.33 na 17.11 .10 114.750 7.0 K 17.5 9.77 na 13 17.0 5.6 9.31 na 17.09 .10 114.750 7.0 M 17.5 9.46 na 14 17.0 5.6 9.74 na 17.48 .10 114.750 7.0 N 17.5 9.74 na 15 17.0 5.6 10.27 na 17.94 .10 114.750 7.0 O 17.5 10.77 na 16 10.08 5.6 16.8 na 22.95 .10 126 7.0 Q 10.08 17.78 na D 8.67 16.49 na E 8.67 16.6 na H 8.67 17.33 na L 8.67 17.45 na P 8.67 18.8 na R 8.67 19.11 na TR 8.67 31.05 na BR4 2.0 43.81 na UG6 -3.0 46.92 na 100.0 SRC2 -3.0 58.82 na The maximum velocity is 23.98 and it occurs in the pipe between nodes R and TR i-inai uaicuiations - tanaara LIFEUARD FIRE PROTECTION Page 6 CASSIA HIEGHTS APARTMENTS Date 9-27-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv £**AAA Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 14.82 1.08 IE 2.305 1.000 7.000 K Factor 5.60 to 120 0.0 2.305 0.0 A 14.82 0.0648 0.0 3.305 0.214 Vel = 5.19 0.0 14.82 7.214 K Factor = 5.52 2 15.29 1.408 0.0 1.000 7.456 K Factor =5.60 to 120 0.0 0.0 0.0 B 15.29 0.0190 0.0 1.000 0.019 Vel = 3.15 0.0 15.29 7.475 K Factor = 5.59 A 14.82 1.408 1 6.617 8.000 7.214 to 120 0.0 6.617 0.0 B 14.82 0.0179 0.0 14.617 0.261 Vel = 3.05 B 15.29 1.408 1 3.308 5.830 7.475 to 120 0.0 3.308 0.0 3 30.11 0.0661 0.0 9.138 0.604 Vel = 6.20 3 15.91 1.408 0.0 10.000 8.079 K Factor 5.60 to 120 0.0 0.0 0.0 4 46.02 0.1451 0.0 10.000 1.451 Vel = 9.48 4 17.29 1.408 0.0 3.670 9.530 K Factor =5.60 to 120 0.0 0.0 0.0 C 63.31 0.2616 0.0 3.670 0.960 Vel = 13.05 0.0 63.31 10.490 K Factor = 19.55 5 17.61 1.08 IT 5.762 1.000 9.886 K Factor =5.60 to 120 0.0 5.762 0.0 C 17.61 0.0893 0.0 6.762 0.604 Vel = 6.17 C 63.31 1.408 1 3.308 3.080 10.490 to 120 IT 6.617 9.925 0.645 D 80.92 0.4120 0.0 13.005 5.358 Vel = 16.67 0.0 80.92 16.493 KFactor= 19.93 6 22.04 1.408 1 3.308 8.340 15.490 K Factor = 5.60 to 120 IT 6.617 9.925 0.433 E 22.04 0.0372 0.0 18.265 0.679 Vel = 4,54 0.0 22.04 16.602 K Factor = 5.41 7 18.34 1.08 IT 5.762 5.500 10.722 K Factor =5.60 to 120 0.0 5.762 0.0 F 18.34 0.0961 0.0 11.262 1.082 Vel= 6.42 0.0 18.34 11.804 K Factor = 5.34 8 18.57 1.08 IT 5.762 2.500 10.992 k Factor =5.60 to 120 0.0 5.762 0.0 F 18.57 0.0983 0.0 8.262 0.812 Vel = 6.50 F 18.33 1.408 IT 6.617 5.000 11.804 to 120 0.0 6.617 0.0 G 36.9 0.0964 0.0 11.617 1.120 Vel= 7.60 Final Calculations - Standard LIFEGUARD FIRE PROTECTION Page 7 CASSIA HIEGHTS APARTMENTS Date 9-27-06 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt PfIUL Eqv. Ln. Total Pf Pn 0.0 36.90 12.924 KFactor= 10.26 9 19.55 1.08 IT 5.762 1.000 12.192 K Factor =5.60 to 120 0.0 5.762 0.0 G 19.55 0.1083 0.0 6.762 0.732 Vel = 6.85 G 36.91 1.408 1 3.308 8.000 12.924 to 120 IT 6.617 9.925 0.611 H 56.46 0.2117 0.0 17.925 3.794 Vel = 11.63 0.0 56.46 17.329 K Factor= 13.56 10 16.28 1.08 1 2.305 2.000 8.456 K Factor 5.60 to 120 0.0 2.305 -0.217 16.28 0.0774 0.0 4.305 0.333 Vel = 5.70 0.0 1.408 0.0 12.080 8.572 to 120 0.0 0.0 0.0 J 16.28 0.0212 0.0 12.080 0.256 Vel = 3.35 0.0 16.28 8.828 K Factor = 5.48 II 16.66 1.408 1 6.617 2.000 8.854 K Factor =5.60 to 120 0.0 6.617 .0.217 J 16.66 0.0222 0.0 8.617 0.191 Vel = 3.43 J 16.29 1.408 0.0 12.080 8.828 to 120 0.0 0.0 0.0 K 32.95 0.0781 0.0 12.080 0.944 Vel = 6.79 0.0 32.95 9.772 KFactor= 10.54 12 17.11 1.08 IT 5.762 2.000 9.332 K Factor = 5.60 to 120 0.0 5.762 -0.217 K 17.11 0.0846 0.0 7.762 0.657 Vel = 5.99 K 32.94 1.408 1E 3.308 12.830 9.772 to 120 IT 6.617 9.925 3.824 L 50.05 0.1694 0.0 22.755 3.855 Vel = 10.31 0.0 50.05 17.451 KFactor 11.98 13 17.09 1.08 1 2.305 2.000 9.309 K Factor =5.60 to 120 0.0 2.305 -0.217 M 17.09 0.0846 0.0 4.305 0.364 Vel = 5.99 M 0.0 1.408 0.0 12.080 9.456 to 120 0.0 0.0 0.0 N 17.09 0.0232 0.0 12.080 0.280 Vel = 3.52 0.0 17.09 9.736 K Factor = 5.48 14 17.48 1.408 IT 6.617 2.000 9.744 K Factor = 5.60 to 120 0.0 6.617 -0.217 N 17.48 0.0243 0.0 8.617 0.209 Vel = 3.60 N 17.09 1.408 0.0 12.080 9.736 to 120 0.0 0.0 0.0 0 34.57 0.0854 0.0 12.080 1.032 Vel = 7.12 rinat uaicuiations - ianuaru LIFEGUARD FIRE PROTECTION Page 8 CASSIA HIEGHTS APARTMENTS Date 9-27-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C't or Ftngs Pe Pv ******* Notes Point at Pf/UL Eqv. Ln. Total Pf Pn 0.0 34.57 10.768 K Factor= 10.53 15 17.94 1.08 IT 5.762 2.000 10.267 K Factor = 5.60 to 120 0.0 5.762 -0.217 O 17.94 0.0925 0.0 7.762 0.718 Vet = 6.28 o 34.57 1.408 1 3.308 12.830 10.768 to 120 IT 6.617 9.925 3.824 P 52.51 0.1851 0.0 22.755 4.212 Vet = 10.82 0.0 52.51 18.804 KFactor= 12.11 16 22.95 1.08 iT 5.762 1.000 16.797 KFactor = 5.60 to 120 0.0 5.762 0.0 Q 22.95 0.1457 0.0 6.762 0.985 Vet = 8.04 Q 0.0 1.408 1E 3.308 8.000 17.782 to 120 IT 6.617 9.925 0.611 R 22.95 0.0401 0.0 17.925 0.718 Vet = 4.73 0.0 22.95 19.111 K Factor = 5.25 D 80.92 2.203 0.0 2.340 16.493 to 120 0.0 0.0 0.0 E 80.92 0.0466 0.0 2.340 0.109 Vet = 6.81 E 22.04 2.203 0.0 10.000 16.602 to 120 0.0 0.0 0.0 H 102.96 0.0727 0.0 10.000 0.727 Vet = 8.67 H 56.46 2.203 0.0 0.750 17.329 to 120 0.0 0.0 0.0 L 159.42 0.1627 0.0 0.750 0.122 VeI = 13.42 L 50.05 2.203 0.0 5.000 17.451 to 120 0.0 0.0 0.0 P 209.47 0.2706 0.0 5.000 1.353 Vet = 17.63 P 52.51 2.203 0.0 0.750 18.804 to 120 0.0 0.0 0.0 R 261.98 0.4093 0.0 0.750 0.307 VeI= 22.05 R 22.95 2.203 1 6.819 18.160 19.111 to 120 0.0 6.819 0.0 TR 284.93 0.4780 0.0 24.979 11.940 Vet = 23.98 TR 0.0 2.203 1 6.819 7.000 31.051 to 120 IZ 6.819 13.638 2.889 BR4 284.93 0.4780 0.0 20.638 9.865 Vet = 23.98 BR4 0.0 4.1 3E 43.601 10.580 43.805 to 140 0.0 43.601 2.166 UG6 284.93 0.0174 0.0 54.181 0.945 Vet = 6.92 UG6 100.00 4.23 4E 76.893 81.500 46.916 Qa100 to 150 IT 38.446 119.183 7.280 * Fixed toss = 7.280 SRC2 384.93 0.0230 1 3.845 200.683 4.619 Vet = 8.79 lZwd 0.0 0.0 384.93 58.815 K Factor = 50.19 i-mat taicuiations - tanaara UFEUARD FIRE PROTECTION Page 9 CASSIA HIEGHTS APARTMENTS Date 9-27-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv £I.A-LLA Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn FROM :EMCOM ELECTRONIC -. FAX NO. :619 667 1222 Feb. 23 2007 09:57AM Fl TvAto W.4 ECTEON, IESTINC, AND MAINTENANCE 72-101 INSPECTION AND TESTING FORM f. U (.L L DATE:, 2/3/O. TIME: 7 ' C fll SERVICE ORGANIZATION PROPERTY NAME (USER) Name: efllco v1 Name'_fl•f Addree Addres _cOi/ b lcpntative; ni I?-O....FLoi Owner Conta 1.URi' L,icenee NoTfl l QO L 1.0 'e O Telephone, 2L±f) S- ZSc20 ............... TcIphon.((O') 17 1X MONITORING ENTITY . APPROVING AGENCY Conuct Contact: C, ?J9J') f,fE DEPr - Telephone: Thlophone,,,,.... .\lonitoi'lng Account Ref No: 6kVqf R-602-7-31M TYPE TRANSMISSION SERVICE j McCulloh 0 Weekly j 'Multiple.x 0 Monthly l.)igitol 0 Quarterly .J Reverse Priority 0 Semiannually j RP Annu1ly J Other (Specify) 0 Other (Specify) . Control Unit Manufacturer: it It Circuit Styles: Number of Circuite: Software Rev. Lost Date Sytexn Had Any Service Performed; Lost Dote that Any Software or Configuration Was oviscd: - Model No, .ffi...., .... ALARM-INITIATING DEVICES AND CIRCUIT INFORMATION Quantity Circuit Style . Manual Fire Mario Boxes Ion Detectors Photo Detectors a..... ___ .Aiarni verification feature is disabled enabled Duct Detectors Heat Detectors Waterfiow Switches Supervisory Switches Other (Specify); (NFPA Inspection and Testing, 1 of 4) 2002 Edition FROM :EMCOM ELECTRONIC FAX NO. 619 667 1222 Feb. 23 2007 09:57AM P2 12.-1O2 NATIONAL FIRE ALAB2& CODR NOTIFICATION APPLIANCES AND CI%RCUIT INFORMATION J.ALARM Qua4tIty Ofrouft Strle / O5J911#9 RP, ONLY 8eUs L/I1 1)6 fIt) • '•• _________________ .. I Rorn C7Lu7' Chimes I I-a. 1'a'1 I I Strobes //bfJV .0 $peaes .: .. ...................... Other (Speàil&):. No. of alarm notlncationappllance circuits: '1 . :, Are cucu1ta monitored for integrity? Ys 0 SUPERVISORY SIGNAL-INITIATING DEVICES AND CIRCUIT INFORMATiON Quantity Cfruuit Style ...... Water Temp Site Water Lava) a ' __a a " lT PUaIIIP POWer oirelpuz~" "69 Position Fire Pump Or Pump Controller Trouble; a a Generator In Auto Position 1 Generator or Controller Trouble Switch !rransfer I a 1 Generator Engine Runing L - - •, - - Other: ............................:" ....... ...C:'*. .....j.;"1;Y: ., , -- .: SIGNALING LINECIR ,i;. .., . 0,• a'.• S...,. Qutij ofrCUlt connected to 5y4tem eeNF.PA 72 ,.Table 6.8.1): ....... Quantity_a Style(s) SYSTEM POWER SUPPLIES Primary (fain): . Nominal Voltage . C_ Amps . C' Overcurrent Protection: Type .-- —•ps Location (of Primary SupplyPtuiolbord): ... flijconneotlng Means Location: Secondary (Standby); a . Calculated capacity to operate system, in hours: .— 24 Engine-drivon generator dedicated to Lire alarm ayE4tern: Location of fuel storage: - .... .._... - -- TYPE BATTERY S.. O Dry Cell o Nickel.Cv4iniufli Sealed Lead-Acid O Lead-Acid 0 Other (Specify): mergency or sdby system used as backup to primary power supply, instead of using a secondary puwor supply: rgency system described in NFPA 70, Article 700 Leg4,.,equired standby described in NFPA 70 Article 701 -- Optionadby system described in NFPA 70, Article 702, which also meets the perfcrniuice reauirement'atArticle 700 or 701, - (NFPA Inspection and Testing, 2 of 4) FIGURE 1O.6.2.3 Continued 2002 Edition 0 . WIN i FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 Feb. 23 2007 09:58AM P3 72- lO NOTIFICATIONS ARE MADE Monitoring Entity Building Occupants Building Management. Ohr (Specify) Ai-IJ Notified of Any Impairments PRIOR TO ANY TESTING Yes No 0 O 0 0 O 0 O 0 SYSTEM TESTS AND INSPECTIONS Who nme 1Tfli Comments T'y'PE Control Unit I utrface 1quipment lamps/tEDS Fuses Primary Pow.r Supply Trouble Signals Disconnect Switches (:37oid-Fau1t Monitoring SECONDARY POWER TYPE Battery Condition Load Voltage flisharge Tt Charger Test specific Gravity TRANSIENT SUPPRESSORS REMOTE ANNUNCIATORS NOTIFICATION APPLIANCES Audible Visible peaki'i Voice Clarity Visual Functional 0 0 0 0 Visual Functional Comments & SIN .. Comments: - INITIATING AND SUPERVISORY DEVICE TESTS AND INSPECTIONS Device Visual Functional Factory Measured Type Check Test Setting Setting ' . _______ _______ Pass Fail 11 (NFPA Inspection and TwiIng, 3 ci 4) I Fl(;tJRE 10.62,3 Continued 2002 Ethiun EMERGENCY COMMUNI PhorieSet phone-Jacks Off-Hook rnditoi• Aropi (tie r() Tone Generator(s) call-in Signal System Pf•nc, visual INTERFACE EQUIPMEN (Specify)., - LI (Specify).... .... ... U SPECIAL HAZARD SYST (Specify) (Specify) . ........ 0 (Specify) -- tr. vi U Spociel Procedures - Cmnwn1 __ FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 Feb. 23 2007 09:58AM P4 72--!04 NATIONAL H PJ ALARM (0D1S Funetjor)ill I-i U Li U U Li Device Sininkited Opttin Operation U LI j -J U SUPERVISING STATION MONITORING Yes Nn Time Alarm Sigriul Alarm Rtoration . X U Q Trouble Signal 0 Supervisory Signal U Supervisory Rostoretion U NOTIFICATIONS THAT TESTING IS COMPLETE Yea No who Building Management L Monitoring Agency 0 Building 000upDnte U U Other (Specify) U - The following did not, operate correctly: ... ...... ______ Syate.m motored to normal operation: Date: .c7547.Tune: THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA ST ND lIDS. Nainc of Inapector: - Dow: - 0 Ntime. of 0 er Representative: IiG LJRE 10.6.2.3 c;ontin.d 2002 Edition FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 Feb. 23200 58AM P5 EMCOM 02 3/2007 SUBSCRIBER ACTIVITY REPORT PAGE5 00:0 BY ALARM NO. ID: JET * 510 41 MONDE 9TH AVENUE 3970 9TH AVENUE EXCEPT ACTIVITY DATE DAY TIME CONDITION KEYHOLDER:/ COMMENT RPT S CD 2/22/07 THU 14: 15 ABNORMAL ABNORMAL TIME TEST 21:00, L-T-T ** 51006245 LAS FLORE LLAGE APARTMENTS 14±1 NORTH FLORES DRIVE EXCEPTION ACTIVITY DATE DAY TIME COW N KEYHOLDER / MENT RPT RES CD 2/22/07 THU 16:10:46 TESTING EN UNTIL 02 /2007 ( :00:00) SYC CODE: E150 :29 AREA: I CODE: E383 :29 AREA: I ** 51006251 SAGE CANYON APARTNE -BLDG 13 4 STEPHANIE COURT 535-0552 EXCEPTION ACTIVITY DATE DAY TINE C 11101 KEYHOLDER / CO IT RPT RES CD 2/22/07 THU 13:43:32 PHONE LI PHONE FAULT LINE 2 404 13:45: RESTORE TELCO 2 FAULT RESTORE x 51006283 ST MAIM TENANT IMPRVEMENT 237 EAST MAIN SIRE EXCE ON ACTIVITY DATE AY fluE CONDITION KEYHOLDER ;/ COMMENT RPT ES CD 2/2 07 THU 13:46:30 PHONE LA PHONE FAULT LINE 1 40 13:48:20 RESTORE .TELCO 1 FAULT RESTORE 510@6291 CASSTA HEIGHTS 200 5 CASSIA ROAD ) 679-2828 EXCEPTION ACTIVITY yA DATE DAY TIME CONDITION KEYHOLDER / COMMENT RPT RES CD 2/22/07 THU 4:54:58 ABNORMAL ABNORMAL TINE TEST 7:21:20 TESTING MARIO. UNTIL 02/22/2007 (16:00:00) sery ALL SIGNALS x 7:3@:30 SUBSCRIBER 51006291 PUT ON LINE 9:32:01 A/C FAIL A/C POER LOSS: T Feb. 23 27 09:58AM FE FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 E1ICOI 02/23/2007 SUBSCRIBER ACTIVITY REPORT PAGE 6 0:01 BY ALARM NO. ID: JET DATE DAY TIME CONDITION KEYHOLDER / COMMENT RPT RES CD 2/22/07 THU 9:32:04 RESTORE FIRE SUPERVISORY RESTORE 9:32:07 MOTIF? Os & ? TAMPER 9:32:09 RESTORE FIRE SUPERVISORY RESTORE 9:32:53 MOTIF? OS & Y TAMPER 9:32:55 RESTORE FIRE SUPERVISORY RESTORE 9:32:58 MOTIF? OS & Y TAMPER 9:33:01 RESTORE FIRE SUPERVISORY RESTORE 9:33:46 FIRE FIRE/SMOKE DETECTOR 0 PANEL 9:33:48 RESTORE FIRE ALARM RESTORE 9:33:51 FIRE FIRE/PULL STATION 0 PANEL 9:38:54 RESTORE AC LOSS RESTORE 9:41:08 MOTIF? OS & Y TAMPER 9:41:11 RESTORE FIRE SUPERVISORY RESTORE 9:41:14 RESTORE FIRE ALARM RESTORE 9:42:26 A/C FAIL A/C POER LOSS 9:42:28 FIRE FIRE/ATERFLDU-IN UNITES 9:43:58 RESTORE FIRE ALARM RESTORE 9:44:00 FIRE FIRE/UATERFLOU-IN UNITES 9:45:16 RESTORE FIRE ALARM RESTORE 9:52:27 RESTORE AC LOSS RESTORE 9:54:17 FIRE FIRE/UATERFLOU-.IN UNITES 9:58:20 A/C FAIL A/C POUER LOSS 9:58:22 RESTORE AC LOSS RESTORE 10:02:30 RESTORE FIRE ALARM RESTORE 10:03:13 FIRE FIRE/ATERFLU-BASENENT PARKING 10:04:59 A/C FAIL A/C POUER LOSS 10:05:03 RESTORE AC LOSS RESTORE 10:06:55 RESTORE FIRE ALARM RESTORE 10:08:28 A/C FAIL A/C POUER LOSS 10:08:31 RESTORE AC LOSS RESTORE 10:11:50 A/C FAIL A/C POUER LOSS 10:17:12 RESTORE AC LOSS RESTORE 10:31:30 FIRE FIPE/UATERFLO-IN UNITES 10:32:12 RESTORE FIRE ALARM RESTORE 10:35:04 FIRE FIRE/UATERFLIJ-BASEMENT PARKING 10:35:47 RESTORE FIRE ALARM RESTORE 10:35:50 A/C FAIL A/C POUER LOSS 10:37:03 TROUBLE SYSTEM TROUBLE 10:39:53 RESTORE SYSTEM TROUBLE RESTORE 10:42:57 RESTORE AC LOSS RESTORE 10:53:04 A/C FAIL A/C POUER LOSS, 1152:06 RESTORE AC LOSS RESTORE 1152:08 A/C FAIL A/C POUER LOSS 1153:25 RESTORE AC LOSS RESTORE 12:23:45 NOTIFY OS & '(TAMPER 12:23:48 RESTORE FIRE SUPERVISORY RESTORE 12:23:51 NOTIFY OS &? TAMPER 12:23:55 RESTORE FIRE SUPERVISORY RESTORE 12:23:58 NOTIFY OS & Y TAMPER 12:24:00 RESTORE FIRE SUPERVISORY RESTORE 12:24:03 NOTIFY OS & V TAMPER Feb. 23 207 09:59AM F? FROM :EMCOM ELECTRONIC FAX NO. :519 567 1222 E1COfl @2/23/2007 SUBSCRIBER ACTIVITY REPORT PAGE 7 00:01 BY ALARM NO. ID: JET DATE DAY TIME CONDITION KEYHOLDER 7 COMMENT RPT RES CD 2/22/07 THU 12:24:06 RESTORE FIRE SUPERVISORY RESTORE 12:24:09 NOTIFY OS & Y TAMPER 12:24:11. RESTORE FIRE SUPERVISORY RESTORE 12:24:14 NOTIFY Os & Y TAMPER 12:24:17 RESTORE FIRE SUPERVISORY RESTORE 12:24:20 NOTIFY OS & Y TAMPER 12:24:23 RESTORE FIRE SUPERVISORY RESTORE 13:03:0@ FIRE FIRE/UATERFLU-BASEMENT PARKING 13:12:48 A/C FAIL A/C POUER LOSS 13:14:50 TROUBLE SYSTEM TROUBLE 13:19:36 RESTORE SYSTEM TROUBLEPESTORE 13:19:39 FIRE FIRE/UATERFLOUIN UNITES 13:19:42 TROUBLE SYSTEM TROUBLE 13:20:24 RESTORE SYSTEM TROUBLE 'RESTORE 13:21:07 RESTORE FIRE ALARM RESTORE 13:21:10 RESTORE FIRE ALARM RESTORE 13:21:13 FIRE FIRE/UATERFLOU-IN UNITES 13:21:16 RESTORE AC LOSS RESTORE 13:21:19 NOTIFY OS & Y TAMPER 13:21:21 RESTORE FIRE SUPERVISORY RESTORE 13:21:25 NOTIFY OS & V TAMPER 13:21:28 RESTORE FIRE SUPERVISORY RESTORE 13:21:31 NOTIFY OS & V TAMPER 13:21:34 RESTORE FIRE SUPERVISORY RESTORE 13:23:25 RESTORE FIRE ALARM RESTORE 13:23:29 FIRE FIRE/UATERFLO-iN UNITES 13:26:50 TROUBLE SYSTEM TROUBLE 13:26:54 RESTORE SYSTEM TROUBLE RESTORE 13:27:37 RESTORE FIRE ALARM RESTORE 13:27:39 FIRE FIRE/UATERFLOU-.IN UNITES 13:29:40 RESTORE FIRE ALARM RESTORE 13:29:43 FIRE FIRE/UATERFLOU-IN UNITES 13:29:46 RESTORE FIRE ALARM RESTORE 13:32:38 FIRE FIPE/UATERFLOU-.IN UNITES 13:32:42 RESTORE FIRE ALARM RESTORE 13:32:44 FIRE FIRE/UATERFLOU-IN UNITES 13:32:47 RESTORE FIRE ALARM RESTORE 51006292 CASSIA HEIGHTS 2011 CASSIA ROAD EXCEPTION ACTIVITY DATE DAY TIME CONDITION KEYHOLDER I COMMENT 2/22/07 THU 4:01:20 ABNORMAL ABNORMAL TIME TEST 7:21:28 TESTING MARIO UNTIL 02/22/2007 (16:00:00) sry 0 ALL SIGNALS * 7:33:@7 A/C FAIL RPT iFS CD FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 Feb. 23 27 09:59PM PB ENCO1 02/23/2007 SUBSCRIBER ACTIVITY REPORT PAGE 8 .00:01 BY ALARM NO, ID: JET DATE DAY TIME CONDITION KEYHOLDER 1 COMMENT RPT RES CD 2/22/07 THU 7:33:10 RESTORE AC LOSS RESTORE 7:34:46 A/C FAIL 7:34:49 RESTORE AC LOSS RESTORE 7:39:41 SUBSCRIBER 51006292 PUT ON LINE 7:40:59 A/C FAIL A/C POUER LOSS: 7:41:02 RESTORE AC LOSS RESTORE 7:53:05 A/C FAIL A/C POUER LOSS 7:56:52 RESTORE AC LOSS RESTORE 8:37:34 A/C FAIL A/C FOUER LOSS 8:38:25 RESTORE FIRE SUPERVISORY RESTORE 8:38:27 NOTIFY OS & V TAMPER 8:38:31 RESTORE FIRE SUPERVISORY RESTORE 8:38:33 NOTIFY OS & V TAMPER 8:38:37 RESTORE FIRE SUPERVISORY RESTORE 8:41:53 FIRE FIRE/UATERFLOU 8:42:20 RESTORE AC LOSS RESTORE 8:42:23 RESTORE FIRE ALARM RESTORE 8:45:08 FIRE FIRE/PULL STATION 0 PANEL 8:45:36 RESTORE FIRE ALARM RESTORE 8:46:04 FIRE FIRE/SMOKE DETECTOR @ PANEL 8:46:07 RESTORE FIRE ALARM RESTORE 8:46:38 FIRE FIRE/PULL STATON 0 PANEL 8:46:41 RESTORE FIRE ALARM RESTORE 8:46:43 FIRE FIRE/SMOKE DETECTOR 0 PANEL 8:46:47 RESTORE FIRE ALARM RESTORE 8:49:00 TROUBLE SYSTEM TROUBLE 8:49:03 RESTORE SYSTEM TROUBLE RESTORE I I I 51006293 CASSIA HEIGHTS 2017 CASSIA ROAD 679-2828 EXCEPTION ACTIVITY DATE DAY TIME CONDITION KEYHOLDER 1 COMMENT 2/22/07 THU 7:21:36 TESTING MARIO UNTIL 02/22/2007 (16:00:00) sery * ALL SIGNALS ** 7:25:38 RESTORE SYSTEM TROUBLE RESTORE 7:25:40 FIRE 7:25:44 RESTORE FIRE ALARM REStORE 7:25:46 SUPERVIS FIRE SUPERVISORY 7:25:49 RESTORE FIRE SUPERVISORY RESTORE 7:25:52 FIRE 7:25:55 RESTORE FIRE ALARM RESTORE 7:25:58 FIRE 7:26:01 RESTORE FIRE ALARM RESTORE 7:26:03 PHONE LN TELCO 1 FAULT 7:26:07 SUPER VIS FIRE SUPERVISORY 7:26:09 RESTORE FIRE SUPERVISORY RESTORE RPT RES CD I T I I I T I I I I I I FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 EIICOII 02/23/2007 SUBSCRIBER ACTIVITY REPORT PAGE 9 00:01 BY ALARM NO. ID: JET Feb. 23 2007 09:59AM P9 - DATE DAY TIME CONDITION KEYHOLDER ./ COMMENT RPT RES CD 2/22/07 THU 7:26:12 SUPERVIS FIRE SUPERVISORY I 7:26:16 RESTORE FIRE SUPERVISORY RESTORE I 7:26:18 SUPERVIS FIRE SUPERVISORY I 7:26:21 RESTORE FIRE SUPERVISORY RESTORE I 7:26:24 SUPERVIS FIRE SUPERVISORY T 7:26:27 RESTORE FIRE SUPERVISORY RESTORE : 7:26:30 PHONE LX TELCO 2 FAULT 1 7:26:32 FIRE T 7:26:36 RESTORE TELCO 1. FAULT RESTORE I 7:26:38 RESTORE FIRE ALARM RESTORE I 7:26:42 FIRE T 7:26:44 RESTORE FIRE ALARM RESTORE I 7:27:11 SUPERVIS FIRE SUPERVISORY T 7:27:15 RESTORE FIRE SUPERVISORY RESTORE I 7:27:17 FIRE I 7:27:21 RESTORE FIRE ALARM RESTORE I 7:29:31 RESTORE TELCO 2 FAULT RESTORE T 7:38:45 SUBSCRIBER 51006293 PUT ON LINE 8:07:43 A/C FAIL A/C POUER LOSS I 8:07:45 RESTORE AC LOSS RESTORE I 8:07:48 A/C FAIL A/C POUER LOSS I 8:07:51 RESTORE AC LOSS RESTORE I 8:08:19 A/C FAIL A/C POUER LOSS I 8:10:24 RESTORE AC LOSS RESTORE I 8:16:14 A/C FAIL A/C POUER LOSS I 8:22:39 RESTORE AC LOSS RESTORE I 8:26:51 A/C FAIL A/C POUER LOSS: I 8:26:54 FIRE FIRE/UATERFLOU T 8:28:26 RESTORE FIRE ALARM RESTORE I 8:28:54 FIRE FIRE/SMOKE DETECTOR @ PANEL ' T 8:28:56 RESTORE FIRE ALARM RESTORE I 8:29:34 FIRE FIRE/PULL STATION @ PANEL I 8:29:37 RESTORE FIRE ALARM RESTORE T 8:29:40 RESTORE AC LOSS 'RESTORE I 12:42:36 LOU BAIT LOU BATTERY ' I 12:42:39 RESTORE LOU SYSTEM BATTERY RESTORE I 12:44:40 FIRE FIRE/PULL STATION @ PANEL I 12:44:42 RESTORE FIRE ALARM RESTORE T ** 51006294 CASSIA HEIGHTS 2023 CASSIA 679-2828 EXCEPTION ACTIVITY DATE DAY TIME CONDITION KEY HOLDER / COMMENT 2/22/07 THU 7:21:49 TESTING MARIO UNTIL 02/22/2007 (16:00:00) sery ** ALL SIGNALS ft 7:40:48 SUBSCRIBER 51006294 POT ON LINE RPT RESCO FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 Feb. 23 2007 10:00AM PlO ENCO1 02/23/2007 SUBSCRIBER ACTIVITY REPORT PAGE 18 00:01 BY ALARM NO, I ID: JET DATE DAY TIME CONDITION KEYHOLDER 'I COMMENT RPT RES CD 2/22/07 THU 7:44:17 LOU BAIT LOU BATTERY 7:44:20 RESTORE SYSTEM TROUBLE RESTORE 7:44:22 RESTORE LOU SYSTEM BATTERY RESTORE 7:44:26 PHONE LW PHONE FAULT LIME 1 7:44:28 PHONE LW PHONE FAULT LINE 2 7:44:31 FIRE FIRE/UATERFLOU 7:44:34 RESTORE TELCO 1 FAULT RESTORE 7:44:37 RESTORE FIRE ALARM RESTORE 7:45:07 NOTIFY OS & V TAMPER 7:45:10 RESTORE FIRE SUPERVISORY RESTORE 7:45:13 MOTIF? OS & ? TAMPER 7:45:41 RESTORE FIRE SUPERVISORY RESTORE 7:45:43 NOTIFY OS & V TAMPER 7:46:24 RESTORE FIRE SUPERVISORY RESTORE 7:46:27 MOTIF? OS & V TAMPER 7:46:55 RESTORE FIRE SUPERVISORY RESTORE 7:46:58 FIRE FIRE/SMOKE DETECTOR 0 PANEL 7:47:01 RESTORE FIRE ALARM RESTORE 7:47:28 FIRE FIRE/PULL STATION 0 PANEL 7:47:31 RESTORE FIRE ALARM RESTORE 7:49:01 RESTORE TELCO 2 FAULT RESTORE 8:48:35 A/C FAIL A/C POUER LOSS 8:48:38 FIRE FIRE/PULL STATION 0 PANEL 8:48:41 RESTORE FIRE ALARM RESTORE 8:49:21 FIRE FIRE/SMOKE DETECTOR 0 PANEL 8:49:24 RESTORE FIRE ALARM RESTORE 8:55:25 FIRE FIRE/IIATERFLOU 8:57:04 RESTORE FIRE ALARM RESTORE 9:11:04 RESTORE AC LOSS RESTORE 13:12:53 RESTORE SYSTEM TROUBLE RESTORE 13:13:31 FIRE FIRE/PULL STATION 0 PANEL 13:13:33 RESTORE FIRE ALARM RESTORE ------------ LL_51@06295 CASSIA HEIGHTS 2029 CASSIA ROAD EXCEPTION ACTIVITY DATE DAY TIME CONDITION KEYHOLDER / COMMENT PPT RES CD 2/22/07 THU 7:21:56 TESTING MARIO UNTIL 02/22/2007 (16:00:00) seru ** ALL SIGNALS 7:41:37 SUBSCRIBER 51006295 PUT ON LINE 8:14:30 PHONE LI PRONE FAULT LINE 2 8:14:33 PRONE LN PRONE FAULT LINE I 8:14:36 RESTORE TELCO 1 FAULT RESTORE 8:15:30 RESTORE TELCO 2 FAULT RESTORE 8:15:33 FIRE FIRE/PULL STATION-MAIN ENTRY 8:16:09 RESTORE FIRE ALARM RESTORE FROM :EMCOM ELECTRONIC FAX NO. :619 667 1222 Feb. 23 2007 10:00AM P11 ENCON 02)23/2007 SUBSCRIBER ACTIVITY REPORT PAGE 11. 00:01 BY ALARM NO. ID : JET DATE DAY TIME CONDITION KEYHOLDER I COMMENT OPT RES CD 2/22/07 THU 8:16:37 FIRE FIRE/SMOKE DETFCTOR 0 PANEL 8:16:39 RESTORE FIRE ALARM RESTORE 8:16:42 NOTIFY OS &'? TAMPER 8:16:45 RESTORE FIRE SUPERVISORY RESTORE 8:16:48 FIRE FIRE/UATERFLOU 8:16:51 RESTORE FIRE ALARM RESTORE 8:32:46 A/C FAIL A/C POUER LOSS 8:32:49 RESTORE AC LOSS RESTORE 8:32:52 A/C FAIL A/C PURER LOSS 8:32:55 RESTORE AC LOSS RESTORE 8:32:58 A/C FAIL A/C PORER LOSS 8:35:02 RESTORE AC LOSS RESTORE 9:12:20 FIRE FIRE/UATERFLO.0 9:14:22 RESTORE FIRE ALARM RESTORE 9:14:50 FIRE FIRE/PULL STATION-MAIM ENTRY 9:14:52 RESTORE FIRE ALARM RESTORE 9:15:44 FIRE FIRE/SMOKE DETECTOR 0 PANEL 9:15:47 RESTORE FIRE ALARM RESTORE 9:17:26 FIRE FIRE/UATERFLOU. 9:18:22 RESTORE FIRE ALARM RESTORE 14:03:51 NOTIFY OS & Y TAMPER 14:03:54 RESTORE FIRE SUPERVISORY RESTORE A ** 5103 M ISSION (951) 695-5287 VILLAGE APARTMENTS 28499 (95 PUJOL ST CTI EXCEPTION CTIVITY DATE DAY ME CONDITION KEYHOLDER CONN RPT RES CD 2/22/07 TROUBLE GROUND FAULT . RESTORE RESET GROUND FAUL ** 52001208 TRANSB0RDERAZ (619) 442-9 EXCEPTION ACTIVITY DATE DAY TIME CONDII 2/22/07 THU 10:00:02 L-T-T OTAY MESA ROAD / COMMENT RPT RES CD ** 52001246 GRAND/91TION VILLAGE AIL 577 SOUTH RANCHO SANTA FE ROAD EXCEPTION ACTI DATE DAY TIM KEYHOLDER COMMENT RPT RES CD 2/22/07 THU 8:00: &43: ABNORMAL TIME TEST