HomeMy WebLinkAbout2010 CASSIA RD; ; FA070040; Permit11/3/2020 FA070040 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2010 CASSIA RD Permit Type: FALARM Parcel No: 2150210100 Lot #: 0 Reference No.: Permit No: FA070040 Status: ISSUED Applied 4/12/2007 Approved: 4/12/2007 Issued: 4/12/2007 PC #: Inspector: Project Title: ALL CATS HOSPITAL TWO FIRE ALARM INSPECTIONS AT $62/EA Applicant: Owner: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Fees ($) Add'I Fees ($) Total ($) Balance ($) 124 0 124 0 1/1 ALL CATS HOSPITAL 2010 CASSIA ROAD CARLSBAD, CA. 92009 FIRE ALARM SUBMITTAL VOTED rCI pp3'ED, RESUBMIT s c' FCR 1 Esc CCIC-1 jf TH WTh ThE VE Th1 On Is 10 BE ft0 M ThE OB 00 1,0 IRE U P3.L Submitted By: M,&- 3830 Calle Fortunada San Diego, CA 92123 (858) 654-3173 C-10 # 707408 Contact: Stacey Tescier FA OT0040 S . ALL CATS FIRE ALARM SUBMITTAL QTY DESCRIPTION MODEL # MANF. CSFM# 1 FIRE ALARM CONTROL PANEL FOCUS CADET ADT/ADEMCO 7165-1645:146 1 FIRE ALARM ANNUNCIATOR 741210 ADT/ADEMCO 7165-1645:146 18 SMOKE DETECTOR 429CAD ESL 7272-0447:128 12 HEAT DETECTORS 5602 SYS SENSOR 7270-1653:167 2 CONNECTION TO EXISTING DUCT DETECTORS FOR SFD CONTROL . LOT 18/2 FIRE CABLE 740132 ADT/PAIGE/GENISIS 7161-1487:100 LOT 14/2 FIRE CABLE 740133 ADT/PAIGE/GENISIS 7161-1487:100 LOT 18/4 FIRE CABLE 740134 ADT/PAIGE/GENISIS 7161-1487:100 0 FOCUS® CADET UL Listed Commercial Fire/Burglar and Access Control Security System WPROVED USL S789 (FOCUSCADET) GENERAL The ADT FOCUS CADET is an economical, user-friendly, programmable, electronic security system that links a facilities detectors with a single microprocessor-based control unit. The FOCUS CADET allows you to control hundreds of critical fire and security functions from one menu-driven interface as simple to use as the automated teller machine (ATM) at your local bank. FEATURES Control of up to 64 input/output protection points in as many as four independent groups from one central location. 1 built-in supervised bell outputs for compliance with local FA requirements as well as for use with BA applications. Up to 32 2-wire smoke detectors. Built in 4-wire smoke detector power reset. Up to 4 BA partitions. 8 built-in points including two 2- wire smoke detector loops. An RS485 bus employed for communicating and powering the gateways, operation panels, printer interface units, and sensors via gateways. The R5485 bus can handle a 4000ft wire run (which can be extended to 8000ft max. with a repeater). Built-in SIM gateway that serves as interfaces for sensors, output devices and wired expansion modules. A built-in communicator and support for an optional backup dialer for monitoring purposes to a Customer Monitoring Center. Ability to download the programming from a remote location using the ADEMCO Compass Downloader. Programmable scheduling of events to automatically occur at a specific time of day. Manual activation and deactivation of any function. Ability to bypass points for maintenance or service. Up to 99 individual operating panel users, each having unique security privileges. Up to 255 individual card/key reader users, each having unique levels of access. Up to 4 door access control readers. Continuous supervision and identification of faults associated with low battery voltage, AC power and internal or external communication. Capability of employing up to 8 operating panels, with a single operating panel controlling all BA groups. Ability to program automatic activation/deactivation of security groups. SPECIFICATION S - Input power I20VAC., 50/601-z - Output power: 18V, 60Hz. 50VA (1.5A) or 72VA (15A) - Standby B.ttery: 12VDC Sealed Lead acid battery Float Charging Voltage to battery: 13 65 VDC Battery charger range 7 AH - 24 All with 50VA tranfomer / 7 AH 34.4 AH with 72VA transforrrar Low battery Signal: 12VDC - Low battery Cutoff: 9.8VDC Aux. Power #2: 12VDC, iDAmp max. (PlC protected) Notificatior Cir:uit; (BELL 1). 12VDC, 1.7 AMP Max. (Style ')(PTC Protected) AUX Relay output: Dry contact• rating: 28V2 AMP max. tesisive load Wet:I2VDC, 1. 'AMP max. Current Draw: Standby 300rnA Alarm 44-0mA Temperature Range: 32F (DC) to 120F (49C) COMMUNICATION FORMAT Contact ID CABINET SPECIFICATIONS- 18" Hx14-1/2VIx4.3' D SYSTEM CAPACITY Total programmable nputloutput points: 34 Operating Panels: 8. Notification Bell Cl-cults 1 Number of users. 255 F rst 99 may Le ID codes and/or card keys Remaining are card/key users only Partitions: 4 History Log: 512 eients tqcc 0 A real-time clock for keeping track of time, day of week and date. Control and recording of employee access to workplace areas along with time and date. History file with 512-event capacity. Supports a hard-copy printer to be connected via printer interface units. 2 built-in output triggers. Provisions for customer to remotely test motion detection sensors vault sensors, BA groups and connected bells, eliminating the need for walk tests. Built-in low battery cut-off. Capable of wireless expansion for quick keys, panic buttons and money clips. Self-test of control unit upon power up. Built-in auxiliary relay interface, which can be set for 4-wire smoke detector reset operation. Agency Listings The FOCUS CADET system complies with UL609, UL611, UL864, UL985, UL1023, UL1610, UL1635, NFPA71 and NFPA72. COMPATIBLE DEVICES, RS-485 BUS 471210: Operating Panel (Interactive Keypad) 472490: RF Gateway 471715: Printer Interface Unit 472270: Access Control Interface Unit 472430: RS-485 Repeater PRODUCT LINE INFORMATION 472511: Main Control Unit. Consists of: - A steel cabinet with key locked front cover - Plug in transformer (1 8VAC/50VA) 472514: Main Control Unit. Consists of: - A UL steel cabinet with key locked front cover - Plug in transformer (1 8VAC/50VA) 472450: Assault Sensor /Required if the control unit is mounted outside of a protected area. 472404: 18VAC/72VA wired in transformer /May be required for some commercial installations. 248222: Wire Lead Kit for Batteries. 472402A: Backup Dialer 477967: Battery, 12-Volt 7.0AH Sealed Lead-Acid SIM TRUNK DEVICES 472366: Sensor Interface Module (SIM) /Used for interfacing sensors not already equipped with a SIM. 472370: SIM FA Pull Station I Manual Fire-Alarm Pull Box. 472374: SIM Holdup Alarm Switch / A finger-operated holdup device. 472488: Supervised Horn/Strobe SIM for interfacing various types of horn/strobes that are not already equipped with a SIM (use with P1215 Horn Strobe or any other ADT approved indicating device). 633S1M: SIM Long Range PIR (80'x80' 200ft long range) 450SlM: SIM PIR (35'x35' w/50ft curtain range) - 669S1M: SIM PIR (60ft DIA. 18 curtain ceiling mount) 472452: Embedded SIM Door Contact. 472418: Steel Door adapter for embedded contact. 429CTAD: SIM Smoke Detector / An ESL Model Smoke Detector. 472367: SIM Door Contact / surface-mount white magnetic door contact. 472392: Door Contact Spacer / surface-mount white magnetic door contact spacer. 472417: SIM Door Contact / surface-mount brown magnetic door contact. 472423: Door Contact Spacer / surface-mount brown magnetic door contact spacer. - 472371S: SIM Overhead Door Contact / surface-mount waterproof overhead magnetic door contact. 248302: Fuse Holder Kit / For preventing "pulling down" of power from a SIM gateway due to a short circuit. DV1201: FOCUS-WS Vault and Safe Vibration Sensor / Used in reverberant or non-reverberant vaults. 472372: Power Supply Module: The module comes with terminals for connecting an input transformer, for connecting a battery, for 12VDC power connections, and for connecting a SIM or PID to supervise the application of AC power. ADDITIONAL SIM BUS DEVICES 4208U: Universal 8-Point Expansion Module - Provides 8 EOLR supervised points. 42085NF: Universal Class A Module r Provides 6 Class B supervised points and 2 Class A supervised points. 4209U: Universal Group Zoning Multiplex Module n Provides 4 additional Two-Wire Smoke Detector Loops (Up to 16 Two-Wire smoke detectors for each loop). 4297: Polling Loop Extender Module ,' Used to extend the polling loop an additional 4000ft (total), Can also be used to extend the SIM Loop. t4C0 One Town Center Road . 1#1121 Boca Raton, FL 33486 0 2000 ADT Security Services, Inc. www.adt.com FOCUS CADET Installation and Setuv Guide Table 7: TOTAL STANDBY CURRENT LIMITS Standby Time/Alarm Time Total Standby Current Total Standby Current SOVA with 24AH Battery 72VA with 34.4AH Battery Residential BA: LOA LOA 4 hours standby + 4 minutes alarm Mercantile BA: 1.OA LOA 4 hours standby + 15 minutes alarm Residential FA: 605mA LOA 24 hours standby + 4 minutes alarm Local or Central Station Commercial FA: Not Applicable LOA 24 hours standby + 5 minutes alarm Remote Station FA: Not Applicable 2 18mA 60 hours standby + 5 minutes alarm Bank Safe and Vault BA: Not Applicable 132mA 72 hours standby + 15 minutes alarm After deciding which devices will be carried by the supplementary power supply, if used, revise Tables 3 through 6 to reflect the total control unit peripheral standby and alarm currents. Determining the Size of the Standby Battery The standby battery must be capable of powering the various sensors and sounding devices, as well as the control unit and its internal accessories, for predetermined periods of time. Use the following worksheets to calculate the required size of the standby battery. Battery Current Calculation Worksheet The values in Table 8 are fixed. Use these values in Table 9 to calculate the total battery currents. Table 8: FOCUS CADET PCB CURRENT CIRCUIT BOARD CURRENT Total Current Standby Alarm Includes 2-wire smoke detector loading on points 1 & 2 300mA 440mA *472402A Backup Dialer Module 5mA iSmA (inactive) (active) '472402A actually draws 55mA when active. However, because FOCUS CADET PCB current includes the built-in main dialer, and because the main dialer is inactive when 472402A is active, 472402A imposes only 15mA added current on the FOCUS CADET power supply. 12-8 S Section 12 - Power Requirements In Table 9, enter the calculated combined current, then add to calculate total battery current. Table 9: TOTAL BATTERY CURRENT Total Battery Current Total Current Standby Alarm Combined RS-485 bus, aux. relay and bell totals (see Table 6) Total PCB current (see Table 8) Total battery current (add RS-485 buslaax.relay/bell totals and PCB totals) Battery Capacity Calculation Worksheet Using the total calculated in Table 9, calculate the battery capacity required for the installation. Capacity Formula Calculated Value Standby Capacity For 4-hour standby time: Total standby current X 4 hours X 1.4 contingency factor. For 24-, 60-, or 72-hour standby time: Total standby current X (24 hours) X 1.1 contingency factor. (60 hours) (72 hours) Alarm Capacity For 4-, 5-, or 15-minute alarm time Total alarm current X 0.067 (4 minutes) 0.083 hours (5 minutes) 0.250 hours (15 minutes) Total Capacity Add standby and alarm capacities Battery Selection Table From the following table, select one of the standard-size batteries that has a capacity greater than or equal to the capacity calculated in the previous worksheet. All the batteries in this table will fit inside the FOCUS CADET enclosure. 7AH Yuasa NPI2-7 12AH YuasaNP12-12 14AH Yuasa NP7-12 (connect 2 in parallel) 17.2AH Yuasa NPG18-12 24AH Yuasa NP12-12 (connect 2 in parallel) 28AH Yuasa NP7- 12 (connect 4 in parallel) 34.4AH Yuasa NPG18-12 (connect 2 in parallel) 12-9 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 01LISTING No. 7165-1645:146 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: ADEMCO, DBA Honeywell International Inc. 165 Eileen Way, Syosset, NY 11791 Contact: David Kalmus (516) 921-6704 Ext 1910 Fax (516) 364-6953 DESIGN: Models 472462, 472462A, 472511 and 472514 Focus 200 Plus, Focus Cadet combination fire and burglary alarm control unit. Automatic, manual, local, remote station (PPU), central station (PPU) proprietary station (PPU), waterflow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 472462, 472462A, 472511, 472514 Control unit SAFOC200, SAELITE, SAELITEA, Sub-assembly Circuit Board SAFOC200P, SAFOC200PA, SAFOC200-1, SAF200PA, SAF200P 1 COM-UL, 472516, RES-UL Enclosure 443216 or 472404 Transformer RATING: 120 VAC, 18 VAC, Transformer and 12 VDC battery back-up INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances 0 and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings and UL label. APPROVAL: Listed as a combination fire and burglary alarm control units for use with the separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 1999 Edition. Refer to manufacturers Installation Manual for details NOTE: Formerly 7165-0078:197 01-14-2005 TR This listing is based upon technical data submitted by the applicant CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet installation instructions and/or other suitable information sources. Date Issued: JUNE 24, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager rI2 ESL PRODUCT INFORMATION BULLETIN 429 SERIES Self-Diagnostic, Two-Wire, Photoelectric Smoke Detectors Model numbers: 429AT, 429C, 429Cr, 429CRT and 429C5T @ 0 <~> LISTED APPROVID California State Fire Marshal Approved MEA (New York City) Intelligent, self-diagnostics Field replaceable optical chamber Low-profile design Plug-in terminal block Advanced false alarm immunity The ESL 429 Series self-diagnostic, two-wire smoke detectors continually monitor their own sensi- tivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detectors integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. The 429 Series is easily cleaned by simply replacing ESL's proprietary field-replaceable optical chamber. All models are designed to reduce false alarms from dust. insects, RFI and external light. An integral combination rate-of-rise and fixed 135F (571C), 50-foot rated, heat sensor is available with all "T" model detectors (see selection guide). An inte- grated silicon heat sensor and a dedicated micropro- cessor are used to detect heat and perform the rate of rise calculations, for earlier heat detection. continued 0 ESL 429 Series Smoke Detectors Architectural and Engineering Specifications The ESL 429 Series low-profile, self-diagnostic, two-wire smoke detectors woric on the light scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photo-diode as the sensing element. When the amount of light reflected onto the photodiode reaches the sensitivity setting, the smoke sampling rate increases. Three (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects, RF and ambient-light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the optional alarm relay (available in 'R models) to operate. A trouble indica- tion is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing require- ments. An internal 85 dB horn (available in S models) emits a steady tone when the detector alarms and a pulsed tone when power polarity is reversed. Product Data Sensitivity ........................................max 3.1 . 1.0%/ft. mm 3.1 + 0.50%/ft. Operating temperature range .........................32°F to 120°F 0°C to 50°C Operating humidity range .................................0 to 95% RH Minimum voltage - C, CT, CRT, CST ............................8.5V -AT ....................................................6.5V Maximum voltage . C, CT, CRT, CST ...........................33V -AT .....................................................20V Maximum ripple (peak to peak) ......................................10% Typical average standby current ..................................70iA Field wiring size ................................................ 14 - 24 AWG Alarm current.....draws max of 60 mA if not limited by panel The proprietary optical sensing chamber is field replaceable, allowing quick and easy cleaning and maintenance. Models with auxiliary relays are approved for releasing service. The very low profile 429 Series detectors are equipped with a hinged cover, a concealed tamper-resistant latch, and insect screens. All wiring terminates in plug-in, clamp-type screw terminals. The detectors mount to a standard single-gang electncal box, a four-inch octagonal, four-inch square electrical box, or WIREMOLD No. 5739 fixture box. Smoke Detector Spacing On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement, and other conditions or response requirements. Max. avg. polarity reverse current - CST . ................... lOn-LA Sounder specifications ....................................85dB at 10 ft. Heat detector specifications fixed temp . ........................... 135°F ± 5°F (57,2°C I 2.8°C) rate of rise ..... 15°F/mm. & > 105°F (8.3°C/mm. & > 40.6°C) Relay specifications .................2A @ 28 V DC or 120 V AC Packaging ....................10 detectors are packed in a carton Color ............... .................................. white cover/white base with UV inhibitor to prevent yellowing 2-wire compatibility .................. see ESL Compatibility Index Listings UL 268, FM, CSFM and MEA (New York City) for Canadian ULC listed products use 428 series 1.85 (4.70 cm)l 6.1 (15.5 c'iil Selection Guide Designator Feature Description Isolated Fixed Temp. Isolated fixed 135°F (57°C) and rate of rise heat detector, independently trips the LED and alarm H and Rate of Rise Heat relay output. Smoke detector activates internal sounder (local alarm) and auxiliary reiay, but Detector does not latch. Approved as both single station smoke alarm and system heat detector Ideal for hotel, motel and dormitory rooms where smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, strobes, etc. Listed for releasing service. 5 Built-in Sounder 85db built-in sounder alarms when smoke is detected or when power wiring polarity is reversed Integrated Fixed Integrated fixed 135°F (57°C) temperature and rate of rise heat detector offers double protection. T Temp. and Rate of Either heat detector or smoke detector can trip and latch LED and alarm relay outputs. Rise Heat Detector SENTROL Seritrol reserves we right 12345 SW Leveton Dr.. fualaun, OR 97062 to change specifications Tel,: 503.692.4052 Fax: 503.691.7566 ESLH http:I/www.sentroi.com U.S. & Canada: 800.547.2556 ©2000 Sentrol Technical Service: 800.648.7424 p r a d u c c ci I se a L r 0 1 FaxBack: 1.800.483.2495 E-4079-ST7k1000 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE OISTING No. 7272-0447:128 Page 1 of I CATEGORY: Photoelectric Smoke Detector LISTEE: ESL/Sentrol Inc., 12345 SW Leveton Dr., Tualatin, OR 97062 Contact: Gene Hukkanen (503) 691-7369 FAX (503) 691-7575 DESIGN: Model 429-AT, -C, -CAD, -CT, -CTAD, -CRT, -CST or -CSST; and Model 449-AT, -C, - CT, -CRT, -CSRH, -CSRT, -CS(S)T, -CSSTE, -CSTE, -CTE, -CLT or -CSLT photoelectric type smoke detectors. Units may employ an integral heat sensor (1350 F fixed temperature and 150 F per minimum rate of rise) and sounding device. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/temperature rating and UL label. o PPROVAL: Listed as photoelectric smoke detectors for use with separately listed electrically compatible fire alarm control units except *Models 429CAD and 429CTAD are intended for use only with ADT Model Focus 200 (CSFM Listing No. 7165-0085:171). NOTE: Integral heat sensor and sounder are supplemental to smoke detector. *Rev. 07-17-96 I This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 12, 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. A REND, Senior Deputy Program Manager 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer a /0w-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: S - Single- and dual-circuit models - Fixed temp and combination fixed- temp/rate-of-rise 1 35°F or 194°F ratings Plain housing for residential installations (Model 5601 P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang - 3,5Thnd 4" Octagonal - 4" square with square to round plaster ring Reversible mounting bracket Agency Listings ® <~> MEAØ LISTED APPROVED approved $2101 3016008 19903'E 7270-120227 Multiple configuraticns.The 5500 series offers a full-line of configurations to accorr modate a oroad :ange of applications. Both single- and dual-circuit mod&s are available for low- and high- temperature ratings with ether txed tem:Derature or combination fixed temperature/rate-of-rise (ROR) activation, The ROR element of the fixed/ROR models is estorabe o accommodate field-testing. Installation flexibility.To sat sty a variety of installation needs, the 5600 series easily mounts o sin;le-gaig and octagonal back boxes. And these models acccmmcdate four-square back boxes, when used with a square to round plaster ring.The reversible mounting bracket permits both flush- anc surface-mount back box installations. Visual identification. —he 5600 series provides clear markings on the exterior of the unit tc ensure that the proper detector is being used, Alphanumeric characters identify the activation method, as well as the temperature rating, in Fairenheit and Celsius degrees. Fixed temperature modes are dent fied EX, while combination fixed/rate-of-rise units are marked FX/ROR The 5600 series also provides a post-activation indicator in the form of a collector. When the detector is activated, the collector drops from the unit, making it easy to identify the unit in alarm. specmcauons . Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open.The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor. The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 1 '4-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method, The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm, Maximum Installation Temperature 5601 P, 5603,5621, and 5623: 100°F (38°C) 5602,5604,5622, and 5624: 1S0°F (65.6°C) Operating Humidity Range 5 to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4.3cm) Alarm Temperature 5601 P, 5603, 5621, and 5623:135'F (57°C) 5602,5604,5622, and 5624:194F (90°C) Weight 601 (170 grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601 P 5602,5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a square to round plaster_ring ________________________________ Operating Voltage I Contact Ratings 6-12SVAC / 3A 6-28VDC/ 1A 125 VDC / 0.3A 25OVDC/0.1A Input Terminals 14-22 AWG S xi xi C C C 5601P 5602, 5622 5603, 5623 5604,5624 5621 Ordering Information 5601 P Single None 135°F (57°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5602 Single Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) "NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 02 06 System Senso~ 1Y1S'TEiI1 3825 Ohio Avenue. St. Charles, IL 60174 -. oductspabcaoons subject tothangewihoutnouce Mitsystemser,,x.corn (or Phone: 800-SENSOR2 . Fax: 630-377-6495 cu,reuc!nformndud the iat€1Verxonofthl, data shL A05.0351-002.11/06 .41676 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE GISTING No. 7270-1653:167 Page 1 of 1 CATEGORY: Heat Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 5601, 5601 P, 5602, 5621, and 5622 combination fixed-temperature and rate-of- rise type and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models Fixed Temperature Electrical 5601, 5601P 135°F 6-125V AC, 3A 5602 194°F 11 5603 135°F 6-28V DC, IA 5604 194°F 11 5621 135°F 125V DC, 0.3A 5622 194°F 11 5623 135°F 25OV DC, 0.1A 5624 194°F 11 *STALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation V criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. SDate Issued: JUNE 269 2006 Listing Expires June 30, 2007 Authorized By: DIANE K. AREND, Senior Deputy Program Manager