HomeMy WebLinkAbout2010 CASSIA RD; 110; FA080057; Permit11/3/2020 FA080057 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2010 CASSIA RD'0 Permit Type: FALARM Parcel No: 2150210100 Lot #: 0 Reference No.: Permit No: FA080057 Status: ISSUED Applied 9/19/2008 Approved: 9/30/2008 Issued: 9/30/2008 PC #: Inspector: Project Title: ANNA DURKIN DDS FA PLAN CHECK & INSPECTIONS Applicant: ADT SECURITY SERVICES, INC. 3830 CALLE FORTUNADA SAN DIEGO, CA (858) 654-3224 Owner: HARRIS-YUT L L C C/O LYNN A YUT 3655 GARFIELD ST CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance ($) 125 0 125 0 1/1 usia i II I! 2010 CASSIA ROAD 4110 CARLSBAD, CA. 92009 FIRE ALARM SUBMITTAL FILE COPY Submitted By: NA - 3830 Calle Fortunada San Diego, CA 92123 (858) 654-3173 C-tO # 707408 Contact: Stacey Tescier ANNA DURKIN D.D.S. FIRE ALARM SUBMITTAL EXISTllsG EQUIPMENT QTy DESCRIPTION MODEL # MANF. CSFM# 1 FIRE ALARM CONTROL PANEL FOCUS CADET ADT/ADEMCO 7165-1645:146 1 FIRE ALARM ANNUNCIATOR 741210 ADT/ADEMCO 7165-1645:146 18 SMOKE DETECTOR 429CAD ESL 7272-0447:128 12 HEAT DETECTORS 5602 SYS SENSOR 7270-1653:167 2 CONNECTION TO EXISTING DUCT DETECTORS FOR SFD CONTROL LOT 18/2 FIRE CABLE 740132 ADT/PAIGE/GENISIS 7161-1487:100 LOT 14/2 FIRE CABLE 740133 ADT/PAIGE/GENISIS 7161-1487:100 LOT 18/4 FIRE CABLE 740134 ADT/PAIGE/GENISIS 7161-1487:100 NEW EQUIPMENT 9 SMOKE DETECTOR 429CAD ESL 7272-0447:128 6 HEAT DETECTORS 5602 SYS SENSOR 7270-1653:167 FOCUS® CADET UL Listed Commercial Fire/Burglar and Access Control Security System WPROVW USL S789 (FOCUSCADE1) GENERAL The ADT FOCUS CADET is an economical, user-friendly, programmable, electronic security system that links a facilities detectors with a single microprocessor-based control unit. The FOCUS CADET allows you to control hundreds of critical fire and security functions from one menu-driven interface as simple to use as the automated teller machine (ATM) at your local bank. FEATURES Control of up to 64 input/output protection points in as many as four independent groups from one central location. 1 built-in supervised bell outputs for compliance with local FA requirements as well as for use with BA applications. Up to 32 2-wire smoke detectors. Built in 4-wire smoke detector power reset. - Up to 4 BA partitions. 8 built-in points including two 2- wire smoke detector loops. An RS485 bus employed for communicating and powering the gateways, operation panels, printer interface units, and sensors via gateways. - The RS485 bus can handle a 4000ft wire run (which can be extended to 8000ft max. with a repeater). Built-in SIM gateway that serves as interfaces for sensors, output devices and wired expansion modules. A built-in communicator and support for an optional backup dialer for monitoring purposes to a Customer Monitoring Center. Ability to download the programming froma remote location using the ADEMCO Compass Downlo.ader. Programmable scheduling of events to automatically occur at a specific time of day. Manual activation and deactivation of any function. Ability to bypass points for maintenance or service. Up to 99 individual operating panel users, each having unique security privileges. Up to 255 individual card/key reader users, each having unique levels of access. Up to 4 door access control readers. Continuous supervision and identification of faults associated with low battery voltage, AC power and internal or external communication. Capability of employing up to 8 operating panels, with a single operating panel controlling all BA groups, Ability to program automatic activation/deactivation of security groups. SPECIFICATIONS Input power; 120VAC, 50/60Hz Output power: 18V, 60Hz1 50VA (1.5A) or 72VA (iSA) - Standby Battery: 12VDC Sealed Lead-acid battery Float Charging Voltage to battery 13 .65 VDC Battery cbarqer ranqe: 7 AH - 24 Low battery Signal: 12VDC Low battery Cutoff: 0,8VDC Aux. Power #2: 12VDC, 1.0Amp max. (PfC protected) Notification Circuits (BELL 1): 12VDC, 1.7 AMP Max. (Style 'r')(FTC Protected) AUX Relay output: Dry contact rating: 28V, 2 AMP max. resistive load Wet;I2VDC, 1,7AMP max. Current Draw: Standby 300mA Alarm 440rnA Temperature Range: 32F (DC) to. 120F (49C) COMMUNICATION FORMAT Contact ID CABINET SPECIFICATIONS 18" I-tx 14-1/2"Wx4,3" D SYSTEM CAPACITY - Total programmable input/output points: 64 Operating Panels: 8 Notification Bell Circuits; 1 Number of users: 255 First 99 may be ID codes and/or card keys Remaining are card/key users only Partitions: 4 History Log: 512 events tqco A real-time clock for keeping track of time, day of week and date. Control and recording of employee access to workplace areas along with time and date. History file with 512-event capacity. Supports a hard-copy printer to be connected via printer interface units. 2 built-in output triggers. Provisions for customer to remotely test motion detection sensors vault sensors, BA groups and connected bells, eliminating the need for walk tests. Built-in low battery cut-off Capable of wireless expansion for quick keys, panic buttons and money clips. Self-test of control unit upon power up. Built-in auxiliary relay interface, which can be set for 4-wire smoke detector reset operation. Agency Listings The FOCUS CADET system complies with UL609, UL611, UL864, UL985, UL1023, UL1610, UL1635, NFPA71 and N F PA7 2. COMPATIBLE DEVICES, RS-485 BUS 471210: Operating Panel (Interactive Keypad) 472490: RF Gateway 471715: Printer Interface Unit 472270: Access Control Interface Unit 472430: RS-485 Repeater PRODUCT LINE INFORMATION 472511: Main Control Unit. Consists of: - A steel cabinet with key locked front cover - Plug in transformer (1 8VAC/50VA) 472514: Main Control Unit. Consists of: - A UL steel cabinet with key locked front cover - Plug in transformer (1 8VAC/50VA) 472450: Assault Sensor /Required if the control unit is mounted outside of a protected area. 472404: 18VAC/72VA wired in transformer /May be required for some commercial installations. 248222: Wire Lead Kit for Batteries. 472402A: Backup Dialer 477987: Battery, 12-Volt 7.OAH Sealed Lead-Acid SIM TRUNK DEVICES 472366: Sensor Interface Module (SIM) /Used for interfacing sensors not already equipped with a SIM. 472370: SIM FA Pull Station / Manual Fire-Alarçn Pull Box. 472374: SIM Holdup Alarm Switch / A finger-operated holdup device. 472488: Supervised Horn/Strobe SIM for interfacing various types of horn/strobes that are not already equipped with a SIM (use with P1215 Horn Strobe or any other AOl approved indicating device). 633S1M: SIM Long Range PIR (80'x80' 200ft long range) 450S1M: SIM PIR (35'x35' w/50ft curtain range) 669SlM: SIM PIR (60ft DIA. 18 curtain ceiling mount) 472452: Embedded SIM Door Contact. 472418: Steel Door adapter for embedded contact. 429C1AD: SIM Smoke Detector / An ESL Model Smoke Detector. 472367: SIM Door Contact / surface-mount white magnetic door contact. 472392: Door Contact Spacer I surface-mount white magnetic door contact spacer. 472417: SIM DoorContact I surface-mount brown magnetic door contact. - 472423: Door Contact Spacer / surface-mount brown magnetic door contact spacer. 472371S: SIM Overhead Door Contact / surface-mount waterproof overhead magnetic door contact. 248302: Fuse Holder Kit / For preventing "pulling down of power from a SIM gateway due to a short circuit. DV1201: FOCUS-WS Vault and Safe Vibration Sensor / Used in reverberant or non-reverberant vaults. 472372: Power Supply Module: The module comes with terminals for connecting an input transformer, for connecting a battery. for 12VDC power connections, and for connecting a SIM or PID to supervise the application of AC power. ADDITIONAL SIM BUS DEVICES 4208U: Universal 8-Point Expansion Module - Provides 8 EOLR supervised points. 4208SNF: Universal Class A Module ñ Provides 6 Class B supervised points and 2 Class A supervised points. 4209U: Universal Group Zoning Multiplex Module ii Provides 4 additional Two-Wire Smoke Detector Loops (Up to 16 Two-Wire smoke detectors for each loop). 4297: Polling Loop Extender Module ii Used to extend the polling loop an additional 40001t (total), Can also be used to extend the SIM Loop. MCC One One Town Center Road . #1121 Boca Raton, FL 33486 0 2000 ADT Security Services. Inc. www.adt.com S FOCUS CADET Installation and Setup Guide Table 7: TOTAL STANDBY CURRENT LIMITS Standby Time/Alarm Time Total Standby Current Total Standby Current SOVA with 24AH Battery 72VA with 34.4A11 Battery Residential BA: LOA LOA 4 hours standby + 4 minutes alarm Mercantile BA: LOA LOA 4 hours standby + 15 minutes alarm Residential FA: 605mA LOA 24 hours standby + 4 minutes alarm Local or Central Station Commercial FA: Not Applicable LOA 24 hours standby + 5 minutes alarm Remote Station FA: Not Applicable 218mA 60 hours standby + 5 minutes alarm Bank Safe and Vault BA: Not Applicable 132rnA 72 hours standby + 15 minutes alarm 6. After deciding which devices will be carried by the supplementary power supply, if used, revise Tables 3 through 6 to reflect the total control unit peripheral standby and alarm currents. Determining the Size of the Standby Battery The standby battery must be capable of powering the various sensors and sounding devices, as well as the control unit and its internal accessories, for predetermined periods of time. Use the following worksheets to calculate the required size of the standby battery. Battery Current Calculation Worksheet The values in Table 8 are fixed. Use these values in Table 9 to calculate the total battery currents. Table 8: FOCUS CADET PCB CURRENT CIRCUIT BOARD CURRENT Total Current Standby Alarm Includes 2-wire smoke detector loading on points 1 & 2 300mA 440mA *472402A Backup Dialer Module 5mA 15mA (inactive) (active) *472402A actually draws 55mA when active. However, because FOCUS CADET PCB current includes the built-in main dialer, and because the main dialer Is inactive when 472402A is active, 472402A imposes only 15mA added current on the FOCUS CADET power supply. 12-8 Section 12 -Power Requirements In Table 9, enter the calculated combined current, then add to calculate total battery current. Table 9: TOTAL BATTERY CURRENT Total Battery Current Total Current Standby Alarm Combined RS-485 bus, aux. relay and bell totals (see Table 6) Total PCB current (see Table 8) Total battery current (add RS-485 bus/aux.relay/bell totals and PCB totals) Battery Capacity Calculation Worksheet Using the total calculated in Table 9, calculate the battery capacity required for the installation. Capacity Formula Calculated Value Standby Capacity For 4-hour standby time: Total standby current X 4 hours X 1.4 contingency factor. For 24-, 60-, or 72-hour standby time: Total standby current X (24 hours) X 1.1 contingency factor. (60 hours) (72 hours) Alarm Capacity For 4-, 5-, or 15-minute alarm time Total alarm current X 0.067 (4 minutes) 0.083 hours (5 minutes) 0.250 hours (15 minutes) Total Capacity Add standby and alarm capacities Battery Selection Table From the following table, select one of the standard-size batteries that has a capacity greater than or equal to the capacity calculated in the previous worksheet. All the batteries in this table will fit inside the FOCUS CADET enclosure. 7A1-1 Yuasa NPI2-7 12AH Yuasa NP12-12 14AH Yuasa NP7- 12 (connect 2 in parallel) 17.2AH Yuasa NPG18-12 24AH Yuasa NP 12-12 (connect 2 in parallel) 28AH Yuasa NP7- 12 (connect 4 in parallel) 34.4A1-I Yuasa NPG18-12 (connect 2 in parallel) 12-9 C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE OISTING No 7165-1645:146 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: ADEMCO, DBA Honeywell International Inc., 2 Corporate Center Drive, Ste 100, Melville, New York 11747 Contact: David Kalmus (516) 921-6704 Ext 1910 Fax (516) 364-6953 DESIGN: Models 472462, 472462A, 472511 and 472514 Focus 200 Plus, Focus Cadet combination fire and burglary alarm control unit. Automatic, manual, local, remote station (PPU), central station (PPU), proprietary station (PPU), water-flow and sprinkler supervisory service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 472462, 472462A, 472511, 472514 Control unit SAFOC200, SAELITE, SAELITEA, Sub-assembly Circuit Board SAFOC200P, SAFOC200PA, SAFOC200-1, SAF200PA, SAF200PI COM-UL, 472516, RES-UL Enclosure 443216 or 472404 Transformer RATING: 120 VAC, 18 VAC, Transformer and 12 VDC battery back-up . INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical ratings and UL label. APPROVAL: Listed as a combination fire and burglary alarm control units for use with the separately listed compatible initiating and indicating devices. This control unit can generate the temporal code pattern fire alarm signal as required per NFPA 72, 2002 Edition. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 81h Edition Standard. NOTE: Formerly 7165-0078:197 01-14-2005 TR 11 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 121, 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief ESL PRODUCT INFORMATION BULLETIN 429 SERIES .. Self-Diagnostic, Two-Wi Photoelectric \J; Smoke Detectors Model numbers: 429AT, 429C, 429Cr, 429CRT and 429CST LISTED APVNOVwD California State Fire Marsriai Approved MEA (New York City) S Intelligent, self-diagnostics Field replaceable optical chamber Low-profile design Plug-in terminal block Advanced false alarm immunity The ESL 429 Series self-diagnostic, two-wire smoke detectors continually monitor their own sense tivity and operational status, and provide a visual trouble indication if they drift out of sensitivity range or fail internal diagnostics. This meets NFPA 72 field sensitivity testing requirements without the need for external meters. Additional diagnostic information is activated by applying a magnet near the detectors integral reed switch. This initiates a self-diagnostic routine and provides visual indication of sensitivity level, or if service is required. The 429 Series is easily cleaned by simply replacing ESL's proprietary field-replaceable optical chamber All models are designed to reduce false alarms from dust. insects, RFI and external light. An integral combination rate-of-rise and fixed 135F (570C), 50-foot rated, heat sensor is available with all "T" model detectors (see selection guide). An inte- grated silicon heat sensor and a dedicated micropro- cessor are used to detect heat and perform the rate of rise calculations, for earlier heat detection. continued ESL 429 Series Smoke Detectors Archttectural and Engineering Specifications The ESL 429 Series low-profile, self-diagnostic, two-wire smoke detectors work on the light scattering principle. A pulsed infrared light-emitting diode serves as the light source, and a high-speed photo-diode as the sensing element. When uie amount of light reflected onto the photodlode reaches the sensitivity setting, the smoke sampling rate increases. Three (3) successive smoke sensings above the sensitivity setting are required to sound an alarm. This design has superior protection against false alarms caused by dust, insects, RF and ambient-light. A confirmed alarm causes the normally flashing power indicator LED to light continuously and the optional alarm relay (available in R" models) to operate. A trouble indica- tion is automatically displayed by flashing the LED every second. This meets NFPA 72 field sensitivity testing require- ments. An internal 85 dB hom (available in S models) emits a steady tone when the detector alarms and a pulsed tone when power polarity is reversed. Product Data SdnSit:vty ...............................max 3.1 1.0%/ft. mm 3.1 + 0.50%/ft. Operating temperature range .........................32°F to 120°F 0°C to 50°C Operating humidity range .................................0 to 95% RH Minimum voltage - C, CT, CRT, CST ............................8.5V -AT ....................................................6.5V Maximum voltage - C. CT, CRT, CST ...........................33V -AT .....................................................20V Maximum ripple (peak to peak) ......................................10% Typical average standby current ..................................70pA Field Mnng size ................................................14 - 24 AWG 0 Aiarrn current .....draws max of 60 mA if not limited by panel Max. avg. polarity reverse current - CST ...... .. ............ 10mA Sounder specifications ....................................85a9 at 10 ft. Heat detector specifications fixed temp .... ........................ 135°F ! 5F (57.2C 28C) rate of rise ..... 15°F/mm. & > 105°F (8.3°C/mm. & > 40 6°C) Relay specifications .................2A @ 28 V DC or 120 V AC Packaging ....................10 detectors are packed in a carton Color ................................ .............. ... white cover/white Dase with UV inhibitor to prevent yellowinc 2-cvire compatibility ..................see ESL Compatibility Index Listings ........UL 268, FM. CSFM and MEA (New York C:ty) for Canadian ULC listed products use 428 series The proprietary optical sensing chamber is field replaceable allowing quick and easy cleaning and maintenance. Models with auxiliary relays are approved for releasing service. The very low profile 429 Series detectors are equipped with a hinged cover, a concealed tamper-resistant latch, and insect screens. All wiring terminates in plug-in, clamp-type screw terminals The detectors mount to a standard single-gang electncal Pox. a four-inch octagonal, four-inch square electrical box, or WIREMOLD No. 5739 fixture box. Smoke Detector Spacing On smooth ceilings (as defined in NFPA 72), spacing of 30 feet (9.1 meters) may be used as a guide. Other spacing may be used depending on ceiling height, high air movement. and other conditions or response requirements. .85 (4.70 cm) (<---z rj) I 61 I tt5SCM) Selection Guide Designator Feature Description Isolated Fixed Temp. Isolated fixed 135°F (57°C) and rate of rise heat detector, independ e n t l y trips the LED and alarm H and Rate of Rise Heat relay output. Smoke detector activates internal sounder (local alarm) and aux i l i a r y r e i a y . Out Detector does not latch. Approved as both single station smoke alarm and syst e m h e a l d e t e c t o r ioeai for hotel, motel and dormitory rooms where smoking is allowed. R Auxiliary Relay Used to activate other devices such as elevator recall, door holders, st r o b e s . e t c . L i s t e d f or releasing service. S Built-in Sounder 85db built-in sounder alarms when smoke is detected or wnen power wiring polarity is reerseci Integrated Fixed Integrated fixed 135°F (57°C) temperature and rate of rise heat detector oilers ixoubie protection T Temp. and Rate of Either heat detector or smoke detector can trip and latch LED and alarm relay outputs. Rise Heat Detector S ENTROL Seritroi reserves tie ,-igrri 1234.5 SW Leveton Or.. Tualaun, OR 97062 to ciiangespecJficat.ons Tel.: 503.692.4052 Fax: 503.691.7566 E SL [, http'Jtw.sentroLconi '©2000 Sentrol U.S. & Canada: 800.547.2556 Technical Service: 800.648.7424 2 r 0 d u c o 1 s e nr o I FaxBack: 1.800.483.2495 or-srs.iocc. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE OLISTING No. 7272-0447:128 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: ESL/Sentrol Inc., 12345 SWLeveton Dr., Tualatin, OR 97062 Contact: Gene Hukkanen (503) 691-7369 FAX (503) 691-7575 DESIGN: Model 429-AT, -C, -CAD, -CT, -CTAD, -CRT, -CST or-CSST; and Model 449-AT, -C, - CT, -CRT, -CSRH, -CSRT, -CS(S)T, -CSSTE, -CSTE, -CTE, -CLI or -CSLT photoelectric type smoke detectors. Units may employ an integral heat sensor (1350 F fixed temperature and 15° F per minimum rate of rise) and sounding device. Refer to listee's data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/temperature rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed electrically . compatible fire alarm control units except *Models 429CAD and 429CTAD are intended for use only with ADT Model Focus 200 series (CSFM Listing No. 7165-1574:157) *and ADT Focus 200 Plus and ADT Focus Cadet (CSFM Listing No. 7165-1645:146). NOTE: Integral heat sensor and sounder are supplemental to smoke detector. Rev. 11-09-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE % 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Engineering Division SYSTEM .4 SENSOR® 5600 Series Mechanical Heat Detectors System Sensor's 5600 series mechanical heat detectors offer low-cost means for property protection against fire, and for non-life-safety installations where smoke detectors are inappropriate. Features Multiple configurations for installations: - Single- and dual-circuit models - Fixed temp and combination fixed- temp/rate-of-rise 135°F or 194°F ratings. Plain housing for residential installations (Model 5601 P) Easy-to-use terminal screws A broad range of back box mounting options: - Single gang - 3.5Thnd 4- Octagonal - 4" square with square to round plaster ring Reversible mounting bracket Agency Listings O @ MEA 0 USTED APPROVED approved 02101 0016008 199-03-E 72701209:227 Multiple configurations. The 5600 series cffès a full-line of configurations to accommodate a broad ranç o applications. Both single- and dual-circuit models are avaiab(e for Law- and high- temperature ratings with either fixed terneratu€ or combination fixed temperature/rate-of-rise (ROR) activaTio.. 1-e ROR element of the fixed/ROR models is restorable to acco'nmodate field-testing. Installation flexibility. To satisfy a variety of rotallation needs, the 5600 series easily r-ounts to single-gang arc octagonal back boxes. And these models accommodate foLr-sqare back boxes, when used with a squa-e to round plaster r!-..g. T-ie reversible mounting bracket permits both flush- and surface-mount back box installations. Visual identification. The 5600 series p°o,ides :lear markings on the exterior of the unit :0 ensure that the coper detector is being used. Alphanumeric characters identify the achvation method, as well as the temperature rating, in Fahrenh.e ad Celsius degrees. Fixed temperature models are identified F, w-dle combination fixed/rate-of-rise units are marked FX/ROR The 5600 series also provides a post-activation indicator in the form ca collector. When the detector is activated, the collector drops f.':m the unit, making it easy to identify the unit in alarm. Specifications .1 Mechanical heat detector shall be a System Sensor 5600 series model number ,listed to Underwriters Laboratories UL 521 for Heat Detectors for Fire Protective Signaling Systems. The detector shall be either a single-circuit or a dual-circuit type, normally open. The detector shall be rated for activation at either 135°F (57°C) or 194°F (90°C), and shall activate by means of a fixed temperature thermal sensor, or a combination fixed temperature/rate-of-rise thermal sensor, The rate-of-rise element shall be activated by a rapid rise in temperature, approximately 15°F (8.3°C) per minute. The detector shall include a reversible mounting bracket for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a square to round plaster ring. Wiring connections shall be made by means of SEMS screws that shall accommodate 14-22AWG wire. The detector shall contain alphanumeric markings on the exterior of the housing to identify its temperature rating and activation method, The rate-of-rise element of combination fixed temperature/rate-of-rise models shall be restorable, to allow for field-testing.The detectors shall include an external collector that shall drop upon activation to identify the unit in alarm. Maximum Installation Temperature 5601 P, 5603,5621, and 5623: 100°F (38°C) 5602,5604,5622, and 5624: 150°F (65.6°C) Operating Humidity Range S to 95% RH non-condensing Dimensions with mounting bracket Diameter: 4.57 inches (11.6cm) Height: 1.69 inches (4,3cm) Alarm Temperature 5601 P, 5603,5621, and 5623: 135°F (57°C) 5602, 5604,5622, and 5624:194°F (90°C) Weight 60z.(170grams) Rate-of-Rise Threshold 15°F (8.3°C) rise per minute (models 5601 P 5602,5621, and 5622 only) Mounting 31/2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-Inch square back box with a square to round plaster ring Electrical Specifications Operating Voltage/ Contact Ratings 6-125VAC / 3A 6-28VDC/1A 125VDC / 0.3A 25OVDC/0.1A InputTerminals - 14-22AWG S mm C S 5601P 5602,5622 5603, 5623 5604, 5624 5621 5601 P Single None 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 152m) 5602 Single Lettering 194°F(90°C) Fixed Temperature /Rate-of-Rise 50 feet xS0 feet (1S.24mx 15.2m) 5603 Single Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5604 Single Lettering 194°F (90°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5621 Dual Lettering 135°F (57°C) Fixed Temperature / Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5622 Dual Lettering 194°F (90°C) Fixed Temperature/ Rate-of-Rise 50 feet x 50 feet (15.24m x 15.2m) 5623 Dual Lettering 135°F (57°C) Fixed Temperature 25 feet x 25 feet (7.62m x 7.62m) 5624 Dual Lettering 194°F (90°C) Fixed Temperature *NOTE: Refer to NFPA72 guidelines for spacing reductions when ceiling heights exceed 10 feet. 25 feet x 25 feet (7.62m x 7.62m) -1 S}'S77EIL'7 5I'JScR° 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2 'Fax: 630-377-6495 PeafiojW5 ".bjec 02006 Sy, em Sem.. c°n U!in ithscithis data si.t CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE GSTING No 7270-1653:167 Page 1 of 1 CATEGORY: Heat Detector LIS TEE System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 5601, 5601 P, 5602, 5621, and 5622 combination fixed-temperature and rate-of- rise type and Models 5603, 5604, 5623, and 5624 fixed-temperature mechanical heat detectors. Refer to listee's data sheet for detailed product description and operational considerations. RATING: Models Fixed Temperature Electrical 5601,5601P 135°F 6-125V AC, 3A 5602 194°F 11 5603 135°F 6-28V DC, 1A 5604 194°F 11 5621 135°F 125V DC, 0.3A 5622 194°F 11 5623 135°F' 25OV DC, 0.IA 5624 194°F 11 WSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, temperature/electrical rating, and UL label. APPROVAL: Listed as heat detectors for use with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. NOTE: Formerly 7270-1209:227 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. is Date Issued JUNE 57 2008 Listing Expires June 30, 2009 Authorized By: BEN HO, Chief Fire Enaineennc, Division fi FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-3 FIRE ALARM SYSTEM RECORD OF COMPLETION Name of protected property: 1Mi. It74V1 Address: 2-010 4-t- T2o( 4t Representative of protected property (name/phone): Authority having jurisdiction: Address/telephone number: Organization name /phone Representative name /phone Installer :;ry4tA tiA' Supplier Service organization i)T Location of record (as-built) drawings: --flrIxx.tt pAtA)- Location of operation and maintenance manuals: AX)L Location of test reports: 0A twUA' A contract for test and inspection in accordance with NFPA standard(s) Contract No(s): Effective date: Expiration date: System Software Operating system (executive) software revision level(s): Site-specific software revision date: Revision completed by: (name) (firm) 1. Type(s) of System or Service NFPA 72, Chapter 6 - Local If alarm is transmitted to location(s) off premises, list where received: NFPA 72, Chapter 8 - Remote Station Telephone numbers of the organization receiving alarm: Alarm: 1D(2,S 62 Supervisory: (e& 2C IS Trouble: I-2& 2-C- jr2 If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8 - Proprietary Telephone numbers of the organization receiving alarm: Alarm: Supervisory: Trouble: If alarms are retransmitted to public fire service communications centers or others, indicate location and telephone numbers of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8— Station Prime contractor: Central station location: (NFPA 72, 1 of 4) FIGURE 4.5.2.1 Record of Completion. 2002 Edition ', 72-32 NATIONAL FIRE ALARM CODE Means of transmission of signals from the protected premises to the central station: McCulloh Multiplex One-way radio - Digital alarm communicator Two-way radio _______ Others Means of transmission of alarms to the public fire service communications center: System location: NFPA 72, Chapter 9—Auxiliary Indicate type of connection: _______ Local energy Shunt _______ Parallel telephone Location of telephone number for receipt of signals: 2. Record of System Installation (Fill out after installation is complete and wiring is checked for opens, shorts, ground faults, and improper branching, but prior to conducting operational acceptance tests.) This system has been installed in accordance with the NFPA standards as shown below, was inspected by includes the devices shown in 5 and 6, and has been in service since NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other (specify): Signed: Date: Organization: 3. Record of System Operation Documentation in accordance with Inspection Testing Form, Figure 10.6.2.3, is attached - All operational features and functions of this system were tested by date and found to be operating properly in accordance with the requirements of: NFPA 72, Chapters 1 2 3 4 5 6 7 8 9 10 11 (circle all that apply) NFPA 70, National Electrical Code, Article 760 Manufacturer's instructions Other (specify): Signed: Date: Organization: Signaling Line Circuits Quantity and class of signaling line circuits connected to system (see NFPA 72, Table 6.6.1): Quantity: Style: Class: I (NFPA 72, 2 of 4) FIGURE 4.5.2.1 Continued 2002 Edition FUNDAMENTALS OF FIRE ALARM SYSTEMS 72-33 fri 5. Alarm-initiating Devices and Circuits Quantity and class of initiating device circuits (see NFPA 72, Table 6.5): Quantity: Style: Class: MAN-UAL (a) Manual stations Noncoded ________ Transmitters__ (b) Combination manual fire alarm and guard's tour coded stations Coded_________ Addressable AUTOMATIC Coverage: Complete Selective Smoke detectors Ion Photo Duct detectors Ion Photo Heat detectors & FT - RR_ Sprinkler waterfiow indicators: Transmitters The alarm verification feature is disabled (U Other (list): Partial Nonrequired Addressable__________ Addressable__________ FIYRR_______ RC, Noncoded________ Coded or enabled _______ , changed from - Addressable - Addressable seconds to seconds. 6. Supervisory Signal-initiating Devices and Circuits (use blanks to indicate quantity of devices) GUARD'S TOUR (a) _........... Coded stations (b)_._...... Noncoded stations (c) Compulsory guard's tour system comprised of ___________ transmitter stations and intermediate stations Note: Combination devices are recorded under 5(b), Manual, and 6(a), Guard's Tour. SPRINKLER SYSTEM Check if provided (a)___...Valve supervisory switches (b)_Building temperature points Site water temperature points Site water supply level points Electric fire pump: (e)—Fire pump power (f) Fire pump running (g)—Phase reversal Engine -driven fire pump: (h)Selector in auto position (1) Engine or control panel trouble (j) Fire pump running ENGINE-DRIVEN GENERATOR: (a)._...._. Selector in auto position (b)_........ Control panel trouble (c) __Transfer switches (d)__..... Engine running Other supervisory function(s) (specify): (NFPA 72, 3 of 4) FIGURE 4.5.2.1 Continued 2002 Edition 72-34 NATIONAL FIRE ALARM CODE 7. Annunciator(s) NumberflI)J() Type: Location: 411 &+ t9k 8. Alarm Notification Appliances and Circuits NFPA 72, Chapter 6 - Emergency Voice/Alarm Service Quantity of voice/alarm channels: Single: Multiple: Quantity of speakers installed: Quantity of speaker zones: Quantity of telephones or telephone jacks included in system: Quantity and the class of notification appliance circuits connected to system (see NFPA 72, Table 6.7): Quantity: Style: Class: Types and quantities of notification appliances installed: Bells With Visible Speakers With Visible Horns With Visible Chimes With Visible Other: With Visible (I) Visible appliances without audible: 9. System Power Supplies Fire Alarm Control Panel: Nominal voltage: Current rating: Overcurrent protection: Type: Current rating: Location: Secondary (standby): Storage battery: Uc'1 Amp-hour rating: Calculated capacity to drive system, in hours: '1 A-h, Engine-driven generator dedicated to fire alarm system: Location of fuel storage: Emergency system used as backup to primary power supply:______________________________________________________ Emergency system described in NFPA 70, Article 700: 10. Comments Frequency of routine tests and inspections, if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s) are: (signed) for installation contractor/supplier (title) (date) (signed) for alarm service company (title) (date) (signed) for central station (title) (date) Upon completion of the system(s) satisfactory test(s) witnessed (if required by the authority having jurisdiction): (signed) representative of the authority having jurisdiction (title) (date) (NFPA 72,4 of 4) FIGURE 4.5.2.1 Continued Ij 2002 Edition