HomeMy WebLinkAbout2011 CASSIA RD; BLDG 2; AS060233; Permit11/3/2020 AS060233 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2011 CASSIA RD Permit Type: SPRINK Parcel No: 2150202700 Lot #: 0 Reference No.: Permit No: AS060233 Status: ISSUED Applied 9/27/2006 Approved: 9/29/2006 Issued: 9/29/2006 PC #: Inspector: Project Title: CASSIA HEIGHTS APTS BLDG. 2 FIRE SPRINKLER INSPECTIONS Applicant: LIFEGUARD FIRE PROTECTION STEF 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 Owner: CITY OF CARLSBAD CALIFORNIA STATE ASSESSED Fees ($) Add'I Fees ($) Total ($) Balance ($) 180 0 180 0 1/1 A J 002 33 APPROVED ASJUITTED LIFEGUARD FIRE PROTECTON INC U APPROVED Tg. 0) APPROVED AS NOTED NOT APPROVED RESUBMIT CHEcio is ONLY FOR CFORM!N I WITh ThE DESIGN cOMCEPT F THE PROtECT AND COMPLIANCE WITH THE iFOPMA1iO GVEN IN THE CONTRACT DOCUM ENTS. CONTRACTOR IS RESPONSIBLE FOR DIMENSIONS TO BE CONFIRMED D CORRELATED AT THE JOB 1 1 AND FOR COORDiNAT OF THE 'QiK OF ALL TRADE& LIFEGUARD FIRE PROTECTION 2605 TEMPLE HEIGHTS DRIVE SUITE "F' OCEANSIDE, CA 92056 760-806-9997 Job Name : CASSIA HIEGHTS APARTMENTS - BUILDING #2 Building : BUILDING 2 Location 2011 CASSIA ROAD System Contract Data File #2UNITCALC.WXF LIFEGUARD FIRE PROTECTION Page 1 CASSIA HIEGHTS APARTMENTS - BUILDING #2 Date 8-16-06 HYDRAULIC DESIGN INFORMATION SHEET Name - CASSIA HIEGHTS APARTMENTS Date - 8-16-06 Location - 2011 CASSIA ROAD Building - BUILDING 2 System No. - Contractor - LIFEGUARD FIRE PROTECTION Contract No. - Calculated By - JEREMIAH BALCH Drawing No. - Construction: ( ) Combustible C ) Non-Combustible Ceiling Height 81 -0" OCCUPANCY - Ri Type of Calculation: )NFPA 13 Residential )NFPA 13R (X)NFPA 13D Number of Sprinklers Flowing: ( )1 ( )2 (X)4 )Other )Specific Ruling Made by Date Listed Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 9.1 Psi (X) Wet ( ) Dry MAXIMUM LISTED SPACING 16 x 16 C ) Deluge ( ) PreAction Domestic Flow Added - Gpm Sprinkler or Nozzle Additional Flow Added - 0 Gpm Make RELIABLE Model RFC43 Elevation at Highest Outlet - Feet Size 1/2" K-Factor 4.3 Note: Temperature Rating 165 F Calculation Gpm Required 52.78 Psi Required 43.06 8 3R2 Summary C-Factor Used: Overhead Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 8-3-06 Rated Cap. Cap. T Time of Test - 8.40 am 8 Psi Elev. E Static (Psi) - 90 Elev. R Residual (Psi) - 84 Other Well Flow (Gpm) - 1244 Proof Flow Gpm S Elevation - P Location: HYDRANTS LOCATED IN PARKING LOT OF CASSIA HIEGHTS JOB SITE P (SEE SITE PLAN L Source of Information: BILL MARSH AND DARIEN MORAN OF LIFEGUARD FIRE Y S Y S T E M D E S I G N Water Supply Curve (C) LIFEGUARD FIRE PROTECTION CASSIA HIEGHTS APARTMENTS - BUILDING #2 Page 2 Date 8-16-06 City Water Supply: Cl - Static Pressure : 81 C2 - Residual Pressure: 75.6 C2 - Residual Flow : 1244 150 140 130 P 120 R 110 E 100 S 90 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N' 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Dl - Elevation : 8.519 D2 - System Flow : 52.7798 D2 - System Pressure : 52.574 Hose (Adj City) Hose ( Demand) D3 - System Demand : 52.7798 Safety Margin : 28.411 - - - Cl C2 80 - U 70 D2 Dl - ....I.I.I.I.... .. I.... I.... Flow Diagram LIFEGUARD FIRE PROTECTION CASSIA HIEGHTS APARTMENTS - BUILDING #2 13.4 I 4.-A 16.9 13 .1 2 J4 13.1, 3 4-C t I 9.2 13. 4 4-D 16.9 9.2 A -+B -.0 *-D 4-E 4 22.4 30.3 20.4 A .*-E i-F *-G i-H 52.8 20.4 32.4 52.8 52.8 F i- H i- TR i- BR2i- UG3+- SRC-5 52.8 52.8 Page 3 Date 8-16-06 Fittings Used Summary LIFEGUARD FIRE PROTECTION Page 4 CASSIA HIEGHTS APARTMENTS - BUILDING #2 Date 8-16-06 Fitting Legend Abbrev. Name Yz % 1 1% 1% 2 2% 3 31/2 4 - 6 8 10 12 14 16 18 R 20 24 E 90StandardElbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 12 R CPVC Coupling Tee-Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 T 90' Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 12 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zwd Watts 709DCDA Fitting generates a Fixed Loss Based on Flow Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Preésure / Flow Summary - STANDARD LIFEGUARD FIRE PROTECTION CASSIA HIEGHTS APARTMENTS - BUILDING #2 Node Elevation K-Fact Pt Pn No. Actual Page 5 Date 8-16-06 Flow Density Area Press 1 16.67 4.3 9.72 na 2 16.67 4.3 9.1 na 3 16.67 4.3 9.33 na 4 16.67 4.3 9.53 na A 17.67 9.82 na B 17.67 9.58 na C 17.67 9.58 na D 17.67 9.84 na E 17.67 21.13 na F 8.67 30.49 na G 8.67 32.63 na H 8.67 34.58 na TR 8.67 37.7 na BR2 2.0 43.07 na 1JG3 -3.0 45.26 na SRCS -3.0 52.57 na The maximum velocity is 11.1 and it occurs in the pipe between nodes E and F 13.4 1.0 9.1 12.97 1.0 9.1 13.13 1.0 9.1 13.27 1.0 9.1 Finl Calculations - Standard LIFEGUARD FIRE PROTECTION Page 6 CASSIA HIEGHTS APARTMENTS - BUILDING #2 Date 8-16-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes **** Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 13.40 1.101 1E 3.825 3.000 9:717 K Factor 4.30 to 150 IT 9.563 13.387 -0.433 A 13.4 0.0325 0.0 16.387 0.532 Vet = 4.52 0.0 13.40 9.816 K Factor = 4.28 2 12.97 1.101 2E 7.65 11.750 9.100 K Factor 4.30 to 150 IT 9.563 18.212 -0.433 B 12.97 0.0305 1R 1.0 29.962 0.915 VeI = 4.37 0.0 12.97 9.582 K Factor = 4.19 3 13.13 1.101 1E 3.825 8.420 9.327 K Factor 4.30 to 150 IT 9.563 13.387 -0.433 C 13.13 0.0313 0.0 21.807 0.682 Vel = 4.42 0.0 13.13 9.576 K Factor = 4.24 4 13.27 1.101 1 3.825 10.000 9.526 K Factor =4.30 to 150 IT 9.563 13.387 -0.433 D 13.27 0.0319 0.0 23.387 0.746 Vet = 4.47 0.0 13.27 9.839 K Factor = 4.23 A -16.93 1.101 1 1.0 3.670 9.816 to 150 0.0 1.000 0.0 B -16.93 -0.0501 0.0 4.670 -0.234 Vet = 5.71 B 12.97 1.101 1 1.0 0.840 9.582 to 150 0.0 1.000 0.0 C -3.96 -0.0033 0.0 1.840 -0.006 Vet = 1.33 C 13.13 1.101 3R 3.0 13.340 9.576 to 150 0.0 3.000 0.0 D 9.17 0.0161 0.0 16.340 0.263 Vet = 3.09 D 13.27 1.101 IT 9.563 103.670 9.839 to 150 1 3.825 30.387 0.0 E 22.44 0.0842 17R 17.0 134.057 11.289 Vet = 7.56 0.0 22.44 21.128 K Factor = 4.88 A 30.34 1.101 0.0 76.920 9.816 to 150 0.0 0.0 0.0 E 30.34 0.1471 0.0 76.920 11.312 Vel= 10.22 E 22.44 1.394 2E 9.523 13.500 21.128 to 150 2T 19.046 28.570 3.898 F 52.78 0.1298 0.0 42.070 5.462 VeI 11.10 F -32.35 1.394 IT 9.523 71.420 30.488 to 150 1E 4.762 24.284 0.0 G 20.43 0.0224 1OR 10.0 95.704 2.145 Vet = 4.29 G 0.0 1.394 18R 18.0 68.830 32.633 to 150 0.0 18.000 0.0 H 20.43 0.0224 0.0 86.830 1.947 Vet = 4.29 0.0 20.43 34.580 K Factor = 3.47 Finél Calculations - Standard LIFEGUARD FIRE PROTECTION Page 7 CASSIA HIEGHTS APARTMENTS - BUILDING #2 Date 8-16-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv **** Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn F 32.35 1.394 IE 4.762 56.670 30.488 to 150 IT 9.523 21.284 0.0 H 32.35 0.0525 7R 7.0 77.954 4.092 Vel = 6.80 H 20.43 1.394 2E 6.302 8.580 34.580 to 120 IR 1.0 7.302 0.0 TR 52.78 0.1962 0.0 15.882 3.116 VeI 11.10 TR 0.0 1.408 1E 3.308 6.670 37.696 to 120 1Z 3.308 6.616 2.889 BR2 52.78 0.1868 0.0 13.286 2.482 Vet = 10.88 BR2 0.0 4.1 2E 29.067 11.750 43.067 to 140 0.0 29.067 2.166 UG3 52.78 0.0008 0.0 40.817 0.031 VeI= 1.28 UG3 0.0 4.23 IG 3.845 25.000 45.264 to 150 IT 38.446 42.290 7.270 * Fixed loss= 7.270 SRC5 52.78 0.0006 lZwd 0.0 67.290 0.040 Vet = 1.20 0.0 52.78 52.574 K Factor = 7.28 AS%0233 Bulletin 136 Rev.M Rellmabld Model Fl FR Model Fl FR Recessed Quick Response Sprinklers Al Model F1 FR Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall - HSW 1 Deflector Model Fl FR Recessed Sprinkler Types Recessed Pendent Recessed Horizontal Sidewall - HSW 1 Deflector Listings & Approvals Listed by Underwriters Laboratories, Inc. (UL) Listed by Underwriters' Laboratories of Canada (ULC) Certified by FM Approvals Loss Prevention Council (LPC, UK) 5, NYC BS&A No. 587-75-SA Meets MIL-S-901C and MIL-SID 167-1 Verband der Schadenversicherer (VdS, Germany) NYC MEA 258-93-E UL Listing Category Sprinklers, Automatic & Open Quick Response Sprinkler UL Guide Number VN IV Patents: US Patent No. 6,374,920 Applies to Model Fl FR Vertical Sidewall Sprinklers. Product Description Reliable Models Fl FR and Fl FR Recessed Sprinklers are quick response sprinklers which combine the durability of a standard sprinkler with the attractive low profile of a decorative sprinkler. The Models Fl FR and Fl FR Recessed automatic sprinklers utilize a 3.0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprinklers. This quick response enables the Model Fl FR and Fl FR Recessed sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. The balance of parts are made of brass, copper and beryllium nickel. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid ex- Upright Pendent Vertical Sidewall Conventional Horizontal Sidewall Recessed Pen ;t HSW 1 Deflector (Model FP Shown) pands, forcing the bubble smaller and smaller as the liquid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflector style and sprinkler type are in accordance with the latest published standards of the National Fire Protection Asso- ciation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers ar I stan- dard response sprinklers should not be intermixeu. de The Reliable Automatic Sprinkler Co., Inc. 525 North MacQuesten Parkway, Mount Vernon, New York 10552 - 2 5/8 DLI. [66.7mmJ - HOLE IN CEILING 2 5/76W 0/A. [587mm] CUP T1 __ IX l/2 REDUCER I I I / CEILING 00 V8 PACE OF Ff77/NC TO PACE OF CEILING DIMENSION(1) ADJUSTMENT' _____________ I36FCO5 (I) REFER TO FP ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS. 2 27/.32 014. 172.2mm1 136/001_C (I) REFER TO TI & /2 ESCUTCHEON DATA TABLE FOR APPROVALS AND DIMENSIONS 2 I/4 HOLE Oa 157.2mmj I I5/I6 Du IX 112" REDUCER TURN COLLAR U/JiLL 170/IT AGAINST SPRINKLER WRENCH BOSS TL777 FACE OF F ADJUSTMENT 03 V~l CELL/NC TO T1 I Model Fl FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Sprinkler Type Standard-Upright (SSU) and Pendent (SSP) Defectors Marked to Indicate Position K Factor Sprinkler Height Num r (SIN) Approval Organization Sprinkler Identification be US Metric SSU SSP /" (15mm) Standard Orifice with /" NPT (R/) Thread 5.6 80 2.2' (56mm) 1,23,4,5,6,7 R3625 R3615 15/1' (20mm) Large Orifice with %" NPT (R34)Thread 8.0 115 2.3" (58mm) 12,3,4,7,8 R3622 R3612 <" (17mm) Small Orifice with /" NPT (R)) Thread 4.2 60 2.2" (56mm) 1,2,8 1R3623 R3613 " (10mm) Small Orifice with X" NPT (R,) Thread 2.8 1 40 2.2" (56mm) 1,2,8 R3621 R3611 10mm Orifice XLH with PDX" Thread 4.2 60 56mm 4,6,7 R3624 R3614 Conventional-Install in Upright or Pendent Position 4.2 5.6 8.0 60 80 115 56mm 56mm 58mm - 4,6,7 4,7 R3674 R3675 R3672 10mm Orifice XLH with Thread 15mm Standard Orifice with Y2 11NPT (R/) Thread 20mm Large Orifice with 3/4I NPT (R3/4)Thread Upright Pendent Conventional Model Fl FR Quick Response Recessed Pendent Sprinkler I Installation Wrench: Model GFR1 Sprinkler Wrench Installation Data Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) US Metric )" (15mm) X" NPT (R½) 5.6 80 2.2" (56mm) 1,2,3,4,5,7,8 R3615 %"(20mm) %" NPT (R3.4) 8.0 115 2.3"(58mm) 1,2,3,8 R3612 /6 (11mm) ," NPT (R½) 4.2 60 2.2'56mm) 1,2,8 R3613 %" (10mm) )' NPr(RYs) 2.8 40 22' (56mm) 1,2,8 R3611 10mm R% 4.2 60 56mm 4,7 R3614 " Refer to escutcheon data table for approvals and dimensions. 2. Horizontal Sidewall Model Fl FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model 0 Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: Nominal Orifice Thread Size K Factor Sprinkler Height Approval Organizations Sprinkler Identification Number (SIN) US Metric ½" l/2 NPT(R½) 5.6 80 2.2" (56mm) 1,2,3,6,8 15mm ½" NPT(R½) 5.6 80 2.2" (56mm) 4(1) R3685 (1) LPC Approval is for Pendent position only. Orientation I Deflector to Ceiling Dimension (Min. - Max.) Upright 4" - 12" (102mm - 305mm) Pendent I 6" - 12" (152mm - 305mm) LL. Vertical Sidewall I US Patent No. 6,374,920 Model Fl FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW 1 Installation Wrench: Model D Sprinkler Wrench Installation Data: Approval Organizations I K Factor and Type of Approval Sprinkler Nominal Orifice Thread Size I Sprinkler Length Identification I Number (SIN) US I I Metric Light Ordinary I Hazard Hazard )11 (15mm) X"NPT(R½) 5.6 80 2.63" (67mm) 1,2,35,8 1,2,5,8 R3635 NOTE: UL, ULC and MEA Listing permits use with Fl or F2 recessed escutcheon. IJ6FG04 OF FITTING TO WALL DIMENSION MIN. 131.Smmj -.2 7/4' HOLE 0/A. 8" [57.2mm] [3.2mm] [12 1.6mm-152.4mmj CEILIN,' TO C X 7/2 DEFLECTOR -A- 1 I5/i501A.LJ 2 27/32" 0/A TURN COLLAR UNT'L -" TIGHT AGAINST SPPINK,IR WRENCH aoss. ADJUS!MLNI (1) RE-ER TO ESCUTHCECN DATA TABLE F-99 APPRO/ALS AND DIMENSIONS. Installation Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. The Model Fl FR Recessed Quick Response Sprinklers are to be installed as shown. The Model Fl or F2 Escutcheons illus- trated are the only recessed escutcheons to be used with the Model Fl FR Sprinklers. The use of any other recessed escutch- eon will void all approvals and negate all warranties. When installing Model Fl FR Sprinklers, use the Model D Sprin- kler Wrench. When installing Model Fl FR Recessed Pendent or Sidewall Sprinklers, use the Model GFR1 Sprinkler Wrench. Any other type of wrench may damage these sprinklers. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. RE- MOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PROTECTION. Re- moval of the protectors before this time may leave the bulb vul- nerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperature Ratings Classification Sprinkler TemDerature Max. Ambient Temp. Bulb Color Ordinary 57 1 135 lWF(38°C) Orange Ordinary 68 I 155 100°F(38°C) Red Intermediate 79 I 175 150°F(66°c) Yellow Intermediate 93 200 1500F(660C) Green High (1) 141j 286 225°F(107C) Blue 11 Not available for recessed sprinklers. Escutcheon Data Escutcheon I.X1 Face of Fithng Model Approvals A4ent Dhiension to Celluig or Wall Dimension 1x" Fl 1,2,4,8 Max Recess (38.1mm) X6 "-'y'6" Min Recess X " (5mm - 24n'v'n) (19.1mm) 1/2 " F2 1,2,3,4,5,7,8 Max Recess (38.1mm) yiell - Min Recess lv " (5mm-17rrnt) (24mm) FP 1,2 ___ Max Recessed _______ Y1611 (11 mm) 1)ç"(38.1mm) Thread-oft 1,2 Mm Recessed 1" (25.4rrrn) (24mm) _ No Dimensional Figure for FP Maintenance The Models F1FR and F1FR Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gen- tle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprin- klers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Sidewall (Vertical, Horizontal HSW1) Recessed Pendent Recessed Horizontal Sidewall HSW1 Finishes ""2' Standard Finishes eon Bronze Sprinkler nBras Chrome Plated (3) White Polyester Coated 3) Special Application Finishes Sprinkler Escutcheon Bright Brass Bright Brass Black Plated Black Plated Black Paint Black Paint Off White Off White Satin Chrome Satin Chrome Other finishes and colors are available on special order. Consult the factory for details. FM Approvals is limited to bronze and brass, chrome or black plated finishes only. FP Push-on/Thread-off escutcheon Ordering Information Specify: Sprinkler Model Sprinkler Type Orifice Size Deflector Type Temperature Rating Sprinkler Finish Escutcheon Type Escutcheon Finish (where applicable) Note: When Model F1FR Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property forover 80 years, and are installed and serviced by the most highly qualified and reputa-ble sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by Reliablee The Reliable Automatic Sprinkler Co., Inc. (800)431-1588 Sales Offices (800)848-6051 Sales Fax (914)668-3470 Corporate Offices www.retiablesprinkIer.com Internet Address ®Recycled Paper Revision lines indicate updated or new data EG. Printed in U.S.A. 7/05 P/N9999970027 elmiabii A Concealed Residential Sprinkler engineered for a minimum design density of 0.05 gpm/ft2 with low GPM requirements. Features 1. Very low water flow requirements. 2.1/21, (13mm) Total adjustment. Thread-On/Thread-Off cover attachment option. Smooth aesthetic ceiling profile. Available in brass, chrome and black plated or painted finishes. Listings & Approval Listed by Underwriters Laboratories, and certified by UL for Canada (cULus) NYC MEA 258-93-E Bulletin 006 Rev.B CD Model RFC43 Concealed Residential Sprinkler (SIN RA0612) UL Listing Categories Residential Automatic Sprinklers UL Guide Number VKKW Product Description Model RFC43 Concealed Residential Sprinklers are fast response residential fusible solder link automatic sprinklers. Residential sprinklers differ from standard sprinklers primarily in their response time and water distribution patterns. Model RFC43 sprinklers discharge water in a hemispherical pattern below the sprinkler deflector. Residential distribution patterns are higher and generally contain a finer droplet size than standard sprinkler patterns. The combination of speed of operation and high discharge pattern required for residential sprinklers has demonstrated, in fire testing, an ability for controlling residential fires, and thereby providing significant evacuation time for occupants. The RFC43 Sprinkler provides the best form of fire protection by combining an attractive appearance and ½" (13mm) of cover adjustment for ease of installation. The small diameter cover plate is easily and positively attached and blends into the ceiling, concealing the most dependable fire protection available, an automatic sprinkler system. The RFC43 is a UL Listed Residential Sprinkler to be installed in the residential portions of any occupancy in accordance with NFPA 13,13R, & 13D. The RFC43 can reduce the need for precise cutting of drop nipples. The threaded cover plate assembly can be adjusted without tools to fit accurately against the ceiling. The fire protection system need not be shut down to adjust or remove the cover plate assembly. Application and Installation The RFC43, for residential installations, uses a 165°F (74°C) fusible solder link in a tuning fork style sprinkler frame with a drop-down deflector. This assembly is recessed into the ceiling and concealed by a flat cover plate. The cover plate is attached to the skirt, using 135°F (57°C) ordinary temperature classification solder. When the ceiling temperature rises, the solder, holding the cover plate releases the cover allowing the deflector to drop into position and exposing the sprinkler The Reliable Automatic Sprinkler Co., Inc., 525 North MacQuesten Parkway, Mount Vernon, New York 10552 inside to ceiling temperature. The subsequent operation of the solder link opens the waterway and causes the deflector to drop into position to distribute the discharging water in a hemispherical pattern below the sprinkler deflector. Any adjustment of thread engagement between the cover plate and cup will assure that the drop-down deflector is properly located below the ceiling. The residential distribution pattern contains a finer droplet size than a standard sprinkler, and the pattern produces significantly higher wall wetting. After a 2 5/8 inch diameter hole is cut in the ceiling, the sprinkler is to be installed with the Model FC Wrench. When installing a sprinkler, the wrench is first positioned into the sprinkler/cup assembly and around the hexagonal body of the sprinkler frame. The Wrench must bottom out against the cup in order to ensure proper, safe installation. The sprinkler is then tightened into the pipe fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART OF THE SPRINKLER/CUP ASSEMBLY. MODEL RFC43 CONCEALED SPRINKLERS MUST BE INSTALLED ONLY WIll-i 135°F RATED COVERS. Cover assemblies provide up to " (13mm) of adjustment. Turn the cover clockwise until the flange is in contact with the ceiling. Cover removal requires turning in the counter-clockwise direction. In ceilings that have a plenum space above the sprinkler, the plenum space may have neutral or negative pressurization but must not be positively pressurized. Inspect all sprinklers after installation to ensure that the gap between the cover plate and ceiling and the 4 slots in the cup are all open and free from any air flow impediment. Temperature Rating Sprinkler Cover Plate Max. Ambient Temp. 165°F/74°c 135°F/57°c 100°F/38°C Installation Data Thread Size inch (mm) K Factor Sprinkler Spacing ft. (m) Maximum I Distance to Wall ft. (m) Minimum Distance between sprinkler ft. (m) Minimum Required Sprinkler Discharge Flow Press. gpm (Lpm) psi (bar) 1/2 (15mm) 4.3 12 x 12 (3.6x3.6) 6(1.83) 8(2.43) 12 (45) 7.8 (0.54) ½" (15mm) 4.3 14 x 14 (4.3x4.3) 7 (2.13) 8 (2.43) 13 (49) 9.1 (0.63) ½" (15mm) 4.3 16 x 16 (4.9x4.9) 8 (2.43) 8 (2.43) 13 (49) 9.1 (0.63) ½" (15mm) 4.3 18 x 18 (5.5x5.5) 9(2.74) 8(2.43) 18 68) 17.5(1.21) ½"(l5mm) 4.3 20x20(6.0x6.0) 10 (3.05) 8(2.43) 21 79) 23.8 (1.64) Note: 1 bar = 100 Kpa Maintenance Model RFC43 Concealed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler cover plate assembly which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. 135°F (570C). Cover plate assembly shall consist of a brass cover plate and copper alloy retainer flange allowing a ½" cover plate adjustment. Any secure engagement between the cover plate and the cup will assure that the drop-down deflector is properly located below the ceiling. A plastic protective cap shall be provided and factory installed inside the sprinkler cup to protect the drop-down sprinkler deflector from damage, which could occur during construction before the cover plate is installed. Standard cover finish: [Chrome] [White] [Specialty -specify]. Residential concealed sprinklers shall be Reliable Model RFC43, SIN RA0612 (Bulletin 006). Model RFC43 Residential Concealed Sprinkler Specification Sprinklers shall be cULus Listed low flow residential concealed sprinklers with drop-down deflector and adjustable flat cover plate engineered for a minimum design density of 0.05 gprrVft2. Sprinkler frame and deflector shall be of bronze frame construction having a ½" NPT thread. Thermal element shall consist of an approved black-painted beryllium-nickel fusible solder link with symmetric lever mechanism, maintaining a Teflon-coated Belleville spring washer and machined brass cap water seal assembly containing no plastic parts. Sprinkler K-factor shall be nominal 4.3(62.4), having a 7/16" orifice. Temperature rating shall be Ordinary 165°F (740C); cover plate temperature rating to be Ordering Information Specify: Sprinkler Model Cover Plate Finish Cover Plate Finishes (1) Standard Finishes Chrome White Special Application Finishes Bright Brass Black Plating Black Paint Off White Satin Chrome (1) Other colors and finishes available. Consult factory for details. Note: Paint or any other coatings applied over the factory finish will void all approvals and warranties. 1" x 1/2" REDUCING TEE OR ELBOW - + '1--- L- -J1. 2 [66.7mm] 0/A. 24" [58.7mm] 0/A - HOLE IN CEILING CUP I 2" [50.8mm] MAX. FACE OF FITTING 1 TO FACE OF CEILING DIMENSION / I CEILING COVER ADJUSTMENT 34" DIA 12.7mm] MAX. COVER PLATE!~J r] -f ASSEMBLY COVER PLATE: 1/2" [12.7mm] ADJUSTMENT C Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from lire around the clock. Automatic sprinklers flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Supertrol electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances, whenever applicable. Products manufactured and distributed by RELIABLE have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by: The Reliable Automatic Sprinkler Co., Inc. Recycled - •... • - .......® (Onn\ AQIlcoo c,,,,., Paper -JCIO 7.11 ces (800) 848-6051 Sales Fax (914) 668-3470 Corporate Offices Revision lines indicate updated or new data www.reliablesprinkler.com Internet Address E.G. Printed in USA. 4)05 PIN 9999970261 ES-7O9DCDA Job Name Job Location Engineer - Approval - Senes 709DCDA Double Check Detector Assemblies Sizes: 3"-10"(80-250mm) Series 709DCDA Double Check Detector Assemblies are designed exclusively for use in accordance with water authori- ty containment requirements. It is mandatory to prevent the reverse flow of fire protection system substances, i.e. glycerin wetting agents, stagnant water and water of non-potable qual- ity from being pumped or siphoned into the potable water line. Benefits: Detects leaks.. . with emphasis on the cost of unac- countable water; incorporates a meter which allows the water utility to: 'detect leaks underground that historically create great annual cost due to waste. provide a detection point for unauthorized use. It can help locate illegal taps. Modular check design concept facilitates maintenance and assembly access. All sizes are standardly equipped with resilient seated OSY shutoff valves, W x 3/4" (16 x 19mm) meter and ball type test cocks. Features Body construction fused epoxy coated cast iron Replaceable bronze seats Maximum flow at low pressure drop 'Compact for economy combined with performance 'Design simplicity for easy maintenance 'Furnished with %" x 3/4" (16 x 19mm) bronze meter 'No special tools required for servicing Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water sup- ply. Degree of hazard present is determined by the local authority having jurisdiction. The unit shall be a complete assembly including UL listed resilient seated OSY shutoff valves and test cocks. The unit shall be UL/FM approved with UL/FM approved OSY shutoff valves. The auxiliary line shall consist of an approved backflow preventer and water meter. The assembly shall meet the basic requirements of ASSE 1048; AWWA Std. C510 for Double Check Valves. Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Assembly shall be a Watts Regulator Company Series 709DCDA. Contractor Approval Contractor's P.O. No. Representative - 7O9DCDAOSY Check / Mo A Cock Cover Seat Disc Check Assembly Module Features a modular design concept which facilitates complete maintenance and assembly by retaining the spring load. First and second check valve spring modules are not inter- changeable. Now Available WattsBox Insulated Enclosures. For more information, send for literature ES-WB. IMPORTANT INQUIRE WITH GOVERMNGAUTHORI17ES FOR LOCAL WSTALLA77ONREQUIREMENrS WWATI'S® REGULATOR Watts product specifications In U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Watts Technical Service. Watts reserves the right to change or modify product design, construction, specifications, or materials with- out prior notice and without Incurring any obligation to make such changes and modifications on Watts products previously or subsequently sold. Materials Body: Epoxy coated cast iron Seat: Bronze Disc Holder: Bronze Trim: Stainless steel Check Valve Discs: Rubber Test Cocks: Bronze Models Suffix: OSY - UL/FM outside stem and yoke resilient seated gate valves CFM - cubic feet per minute meter GPM - gallons per minute meter LF - 4" - 10" (100-250mm) without shutoff valves Dimensions - Weights Pressure - Temperature Temperature Range: 33°F - 110°F (5° - 43°C) continuous, 140°F (60°C) intermittent Maximum Working Pressure: 175psi (12.06 bar) Standards AWWA Standard C510 Approvals ®R.. Iss,F, FM c®us ® B.64 1048 Approved by the foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California. Sizes 4" - 10" (100 - 250mm) approved for horizontal and vertical "flow up". Size 3" (76mm) approved for horizontal o ly. Factory Mutual approved 4" - 10" vertical "flow up". A SIZE (2 DIMENSIONS WEIGHT In. mm in. A mm C In. mm 0 in. mm In. E mm In. L mm In. R mm I in. mm In. U. mm WSYtgates lbs. kgs. 3 80 40 1016 181/a 479 31/2 89 12 305 24 610 14 356 3 76 14 356 190 86 4 100 52 1321 223/4 578 33/4 95 17 432 34 864 15 381 6 152 14 356 403 183 6 150 621h 1588 301A 765 41h 114 21 533 41½ 1054 16 406 7½ 191 16 406 727 330 8 200 75 1905 373/4 959 51h 140 26 660 52 1321 17 432 9 229 21 533 1327 602 10 250 90 2286 45~ 1162 6½ 165 32 813 64 1626 18 457 10¼ 260 25 635 2093 949 * Service clearance for check assembly from center. tULJFM approved backflow preventers must include UL/FM approved OSY. Capacfty *Typical maximum system flow rate (7.5 ft./Sec.) **UL rated flow T _________. ••= i•••• / --== ==... i....• u • _ :•._ -, ------ __u __------ ------- __ —= =------ __I------ ---- ---- ------ ---- ---------- -------- 80 (200mm) rL I- __I • - • I ------ __I - ------ __I 1 400 am 12DD 1600 2000 4000 gpm 1 1520 300 456 6M 7600 15200 Ipm = •• ----- ._ I___. - • ___ I_ • i u•• ----- ._ N 7 i___ ______. For Technical Assistance Call Your Authorized Watts Agent. Telephone # Fax # Ilasaournurs Watts Regulator Company 815 Chestnut St., North Andover, MA 01845-6098 U.S.A. 978 688-1811 978794-184 Edwards, Platt & Deely, Inc. 271 Royal Ave., Hawthorne, NJ 07506 973 427-2898 973 427-4246 Edwards, Platt & Deely, Inc. 368 Wyandanch Ave., North Babylon, NY 11703 631253-0600 631 263-0303 W. P. Haney Co., Inc. 51 Norfolk Ave., South Easton, MA 02375 508 238-2030 508 238-8353 J. B. O'Connor Company, Inc. P.O. Box 12927, Pittsburgh, PA 15241 724 745-5300 724 745-7420 RMI Glenfield Bus. CtL, 2535 Mechanicsville Tpk., Richmond, VA 23223 804 643-7355 804 643-7380 The Joyce Agency, Inc. 8442 Alban Rd., Springfield, VA 22150 703 866-3111 703 866-2332 Vernon Bitzer Associates, Inc. 980 Thomas Drive, Wanninster, PA 18974 215 443-7500 215 443-7573 WMS Sales, Inc. (Main office) 9580 County Rd., Clarence Center, NY 14032 716 741-9575 716 741-4810 Billingsley & Associates, Inc. 2728 Crestview Ave., Kenner, LA 70062-4829 504 602-8100 504 602-8106 Billingsley & Associates, Inc. 478 Cheyenne Lane, Madison, MS 39110 601856-7565 601856-8390 Francisco J. 0r11z & Co., Inc. Charlyn Industrial Pk., Road 190 KM1.9 - Lot #8, Carolina, Puerto Rico 00983 787 769-0085 787 750-5120 Mid-America Marketing, Inc. 203 Industrial Drive, Birmingham, AL 35211 205 879-3469 205 870-5027 Mid-America Marketing, Inc. 1364 Foster Avenue, Nashville, TN 37210 615 259-9944 615 259-5111 Mid-America Marketing, Inc. 5466 Old Hwy. 78, Memphis, TN 38118 901795-0045 901795-0394 Smith & Stevenson Co., Inc. 4935 Chastain Ave., Charlotte, NC 28217 704 525-3388 704 525-6749 Harry Warren, Inc. 1243 West Colonial Dr., Orlando, Fl. 32804 407 841-9237 407 841-9246 Watts Georgia 2861-B Bankers Industrial Drive, Manta, GA 30360 770 209-3310 770 447-4583 Aspinall Associates, Inc. 6840 Hillsdale Court, Indianapolis, IN 46250 317 849-5757 317 845-7967 Dave Watson Associates 1325 West Beecher, Adrian, Ml 49221 517 263-8988 517 263-2328 Disney McLane & Associates 428 McGregor Ave., Cincinnati, OH 45206 800 542-1682 877 476-1682 BWA Company 17610 S. Waterloo Rd., Cleveland, OH 44119 216 486-1010 216 486-2860 Mid-Continent Marketing Services Ltd. 1724 Armitage CL, Addison, 1160101 630 953-1211 630 953-1067 Soderhoim & Associates, Inc. 7150 143rd Ave. N.W., Anoka, MN 55303 763 427-9635 763 427-5665 Stickler & Associates 333 North 121 St, Milwaukee, WI 53226 414 771-0460 414 771-3607 Hugh M. Cunningham, Inc. 13755 Benchmark, Dallas, DC 75234 972 888-3808 972 888-3838 Mack McClain & Associates 11132 South Towne Square, Suite 202, St Louis, MO 63123 314 894-8188 314 894-8388 Mack McClain & Associates, Inc. 1450 NE 69th Place, Ste. 56 Ankeny, IA 50021 515 288-0184 515 288-5049 Mack McClain & Associates, Inc. 15090 West 116th St., Olathe, KS 66062 913 339-6677 913 339-9518 OKI Sales, Inc. 2200 Blue Creek Dr., Norman, OK 73026 405 360-6161 405 360-0092 Phoenix Marketing, Ltd. 2416 Candelaria N.E.,Aibuquerque, NM 87107 505 883-7100 505 883-7101 Delco Sales, Inc. 1930 Raynier Ave., Fullerton, CA 92833 714 888-2444 714 888-2448 Delco Sales, Inc. 111 Sand Island Access Rd., Unit 1-10, Honolulu, HI 96819 808 842-7900 808 842-9625 Fanning & Associates, Inc. 6765 Franklin St, Denver, CO 80229-7111 303 289-4191 303 286-9069 Hollabaugh Brothers & Associates 6915 South 194th St., Kent, WA 98032 253 867-5040 253867.5055 Hollabaugh Brothers & Associates 3028 S.E. 17th Ave., Portland, OR 97202 503 238-0313 503 235-2824 P1 R Sales, Inc. 3050 North San Marcos Place, Chandler, AZ 85225 480 892-6000 480 892-6096 Preferred Sales 31177 Wiegman Road, Hayward, CA 94544 510 487-9755 510 476-1595 R. E. Fitzpatrick Sales, Inc. 4109 West Nike Dr. (8250 South), West Jordan, UT 84088 801282-0700 801282-0600 Watts Industries (Canada) Inc. (Watts Regulator Co. Division) 5435 North Service Road, Burlington, Ontario LX 5H7 905 332-4090 905 332-7068 Con-Cur West Marketing, Inc. 71 B Clipper Street, Coquitlarn, British Columbia V3K 6X2 604 540-5088 604 540-5084 D.C. Sales Corporation Inc. #10-61304th St S.E., Calgary, Alberta T2H 2A6 403 253-6808 403 259-8331 D.C. Sales Corporation Inc. 11420 142 Street, Edmonton, Alberta T5M 1V1 780 496-9495 780 496-9621 GTA Sales Team. Greater Toronto Area 888 208-8927 888 479-2887 Hydro-Mechanical Sales, Ltd. 3700 Joseph Howe Drive, Suite 1, Halifax, Nova Scotia B3L 4H7 902 443-2274 902 443-2275 Hydro-Mechanical Sales; Ltd. P.O. Box 1445(Mailing), 297 Collishaw St., Suite 7 (shipping) Moncton, New Brunswick E1C 9R2 506 859-1107 506 859-2424 J.D.S. Sales Ltd. 4 Lancaster Street, St John's, Newfoundland Al 5P7 709 579-5771 709 579-1558 Le Groupe B.G.T., Inc. 23 du Buisson, Pont Rouge, Quebec G3H 1X9 418 873-2500 418 673-2505 Le Groups B.G.T., Inc. 86 des Enterprises #208, Bolsbnand, Quebec J7G 2173 450 434-9010 450 434-9848 Mar-Win Agencies, ltd. 1333 Clifton St., Winnipeg, Manitoba R3E 2V1 204 775-8194 204 786-8016 Northern Mechanical Sales P.O. Box 280 (mailing) 163 Pine St (shipping), Gerson, Ontario PSL 1S6 705 693-2715 7056934394 Palser Enterprises, Ltd. P.O. Box 28136 (mailing), 1885 Blue Heron Dr., #4, London, Ontario N6H 51.9 519 471-9382 519 471-1049 RAM Mechanical Marketing Inc. 1401 St John Street, Regina, Saskatchewan S4R 1S5 306 525-1986 306 525-0809 RAM Mechanical Marketing Inc. 510 Ave M South, Saskatoon, Saskatchewan S7M 21(9 306 244-6622 306 244-0807 Walmar Mechanical Sales 24 Gurdwara Rd., Nepean, Ontario K2E 855 613 225-9774 613 225-0673 EXPORT Hdqtrs.: Watts Regulator Co. 815 Chestnut St., North Andover, MA 01845-6098 U.S.A. 978 688-1811 978 794-li.48 WATTS® lM19OuiJ Watts USA website: www.wattsreg.com REGULATOR I CERTIFiED I Watts Canada website: www.wattscanada.ca ES-70DCDA 0522 0 Watts Regulator Company, 2005 I Dyna-Thread Full Line Sch-40 Replacement Dyna-Thread' offers the life expectancy of Sch4O with superior hydraulics and greater value. Dyna-Thread sprinkler pipe represents an engineering advancement for the sprinkler pipe industiy. It combines the safety and longevity of traditional Sch-40 pipe with quality and superior hydraulic advantages. Comparison to Schedule 40 Dyna-Thread's inside diameter is up to 3.6% larger than Sch-40 giving it superior hydraulics. And, when used in combination with Dyna-Flow pipe, down sizing often occurs. Dyna-Thread is fully listed and approved by UL, ULC, and FM for fire sprinkler applications. The life expectancy of Dyna-Thread and Sch-40 are equal based on the calculated wall thicknesses per UL. The consistent quality of steel used to make Dyna-Thread facilitates smooth threading and lower maintenance .costs. The exterior of Dyna-Thread is protected by a clean, durable mill coating for extended shelf life and easy paint application. @ <~> 9 Listed Approved Listed With its increased strength and lighter weight, Dyna-Thread reduces installation fatigue and is ideal for retro-fit applications. Corrosion Resistance Ratio (CRR) is a UL (Underwriters Laboratory) term for the estimated life expectancy of a pipe joint. This is based on the calculated wall thickness at the base of the first exposed thread, assumed to be the weakest point of the pipe length. Dyna- Thread and Sch40 have the same calculated wall thicknesses at this point and are both assigned the same CRR of 1.00. The internal surface of all black Allied Tube & Conduit Fire Sprinkler pipe products up to 4.5000" in diameter is coated with our new Antibacterial Formula, "ABF'. In scientific laboratory test, ABS proved to have superior resistance to microbial colonization of pipe walls, thereby delaying or possibly preventing the onset of Microbiologically Influenced corrosion (MIC) when the First Sprinkler System is first installed. More wall thickness at the thread (CRR=1.00) gives Dyna-Thread better life expectancy than lightwall threadable pipe joints. Unlike lightwall threadable pipe, Dyna-Thread has no thread gauge warning. Dyna-Thread is approved for standard hanger spacing (15 ft. O.C.), can be used as earthquake sway bracing, and is safe to use as drops. Dyna-Thread is safer to weld on. Dyna-Thread is more widely accepted than lightwall threadable where Sch-40 is specified. Super 40/Dyna-Thread pipe is manufactured to meet: ASTM A-135, Grade A and is in compliance with NFPA-13. All sizes of Super 40/Dyna- Thread are rated at 300 psi working pressure. Super 40/Dyna-Thread is UL and ULC Listed for wet, dry deluge and pm-action sprinkler systems and FM Approved for use in wet systems. Super 40/Dyna-Thread can be "hot-dip" galvanized to meet FM requirement for dry systems. Super 40fDyna-Thread is approved for all threaded couplings and welded outlets and is suitable for all roll-grooved, and plain-end fittings. (See listing information). Specifications NPS Nominal I.D. WI. WI. (P120 Filled) Pc*' WVUft (21') Wl/IJft (241) Wtflift (25' In; mm In; mm LbsM Kg/rn Lbsflt Kg/rn Lift Lbs; Kg Lbs; Kg Lbs; Kg 1.080 1.330 1.75 70 1955 2234 232 25 27.4 2.0 2.60 70 887 1013 105 1W 1.408 1.870 2.54 51 2002 2288 238 32 35.8 2.8 3.78 51 908 1038 108 1W 1.639 2.290 3.22 44 2115 2418 2511 40 41.6 3.4 4.79 44 959 1097 114 2.104 3.050 4.57 30 1921 2196 228: 50 53.4 4.5 6.80 30 871 996 103, 16100 S. Lathrop• Harvey, IL 60426 Customer Service: tqco/F/ow Control () allied 11350 Norcom Rd. . Philadelphia, PA 19154 (800) 882-5543 TUBE & CONDUIT 2525 N. 27th Ave. • Phoenix, AZ 85009 Fax 708-339-1806 S3-3 tqC0 /Fire & Building I Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 BlazeMaster CPVC Fire Sprinkler Pipe & Fittings Submittal Sheet ,a rapid response HOME FIRE SPRINKLER SYSTEM General Description Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are designed exclusively for use in wet pipe automatic fire sprinkler systems. They are made from a specially devel- oped thermoplastic compound com- posed of post chlorinated polyvinyl chloride (CPVC) resin and state of the art additives. TFBP BlazeMaster CPVC products are easier to install than traditional steel pipe systems, and at the same time, provide superior heat resistance and strength as com- pared to traditional CPVC and PVC piping materials used In the plumbing trade. Various adapters are available to connect CPVC pipe to metallic pip- ing. All female pipe thread adapters have brass inserts for durability. Grooved adapters connect directly to grooved end valves and metallic pipe, with flexible grooved end couplings. WARNING Tyco Fire & Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Technical Data Sizes 3/4" to 3" Maximum Working Pressure 175 psi Approvals UL, FM, CUL, NSF, Dade County, LPCB, MEA, and the City of Los Ange- les. (Refer to IH-1900, Rev. 0, Janu- ary 2005 installation Instruction & Technical Handbook" for exact list- ing/approval information.) Manufacture Source U.S.A. Material Pipe: ASTM F442, SDR 13.5 Fittings: ASTM F438 (Sch. 40) and ASTM F439 (Sch. 80), ASTM F1970 Color Orange BlazeMasfe,° is a registered trademark of Noveon IP Holding Corp. Page 1 of 6 JANUARY, 2006 TFPI9I5 Page 2 of 6 TFPI9I5 WATER NOMINAL AVERAGE AVERAGE WEIGHT FILLED WEIGHT FT. OF PIPE WEIGHT PER LIFT SIZE O.D. I.D. IbsJft. IbsJft. PER LIFT lbs. 3/4" 1.050" 0.874" 0.18 0.44 7875 1339 1.315" 1.101 0.26 0.67 5040 1320 1-1/4" 1660" 1.394" 0.42 1.08 2835 1191 1-1/2" 1.900" 1.598" 0.54 1.41 2205 1213 2.375" 2.003" 0.84 2.20 1260 1084 2-1/2" 2.875" 2.423" 1.26 3.26 1215 1531 3.500" 2.952" 1.87 4.83 720 1344 FIGURE 1— PIPE DIMENSIONS Installation Tyco Fire and Building Products (TFBP) BlazeMaster CPVC Pipe and Fittings are to be installed in accord- ance with IH-1900, Rev. 0, January 2005 "Installation Instruction & Techni- cal Handbook". Care and Maintenance The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any authority having jurisdiction. The in- stalling contractor or product manufac- turer should be contacted relative to any questions. It is recommended that automatic sprinkler systems be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. NOTES Before closing a fire protection system control valve for inspection or mainte- nance work on the fire protection sys- tem that it controls, permission to shut down the affected fire protection sys- tem must first be obtained from the proper authorities and all personnel who may be affected by this action must be notified. After placing a fire protection system In service, notify the proper authorities and advise those responsible for moni- toring proprietary and/or central sta- tion alarms. TFPI9I5 Page 3o16 Page 4of6 TFPI9I5 TFPI9I5 Page 5of6 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHD. WEIGHT TYPE NUMBER (110) SPRINKLER HEAD ADAPTER 80175E 314'x 1/2" NPT 7/16" 80 0.20 80176E 1" x 1/2" NPT 7/16" 80 0.22 80175WL q; 3/4"x 1/2" NPT 7/16" 40 0.16 80179 1"x3/4"NPT 13116" 40 0.43 SPRINKLER HEAD ADAPTER 80175W 3/4"x 1/2" NPT 1/2" 40 0.19 14~T/O 80176W 1"x1/2"NPT 1/2" 40 0.18 SPRINKLER HEAD ADAPTER (SPIGOT) 80177L 3/4"xl/2"NPT 1/2" 40 0.16 0.20 80178 1" x 1/2" NPT 9116" 40 ~;T/O 80180 1" x 3/4" NPT 7/8" 40 0.40 FEMALE ADAPTER 80142 3/4'x 3/4" NPT 13/16" 40 0.41 80145 Vx1"NPT 7/8" 40 0.63 Em 80146 1-1/4"x1-1/4"NPT 1-1/8" 40 1.03 80147 1-1/2"xl-1/2"NPT 1-3/8" 80 1.42 80148 2"x2"NPT 1-11/16" 80 2.66 MALE ADAPTER El 80157 3/4" x 3/4" NPT 1-5/16" 40 0.33 0.56 80158 r xr NPT 1-3/8" 40 XxYxZ X Y Z SPRINKLER HEAD ADAPTER TEE 80250 3/4" x 3/4" x 1/2" NPT 9/16" 9/16" 1" 40 0.22 z 80251 1" xl" x 1/2" NPT 11/16" 11/16" 1-3/16 40 0.29 T/O 80249 1"x 1"xl" NPT 15/16" 15/16" 1-9/16" 40 0.73 80256 1-1/4"x l" x 1/2" NPT 7/16" 9/16" 1-5/16" 40 0.30 80252 1-1/4" x 1-1/4"x 1/2" NPT 7/16" 7/16" 1-5/16" 40 0.31 80257 1-1/2" x 1-1/4" x 1/2" NPT 1/2" 11/16" 1-7/16" 80 0.43 80254 1-1/2"x 1-1/2"x 1/2" NPT 1/2" 1/2" 1-7/16" 80 0.46 _______ T/0 I I Tb 80258 2"x1-1/2"x1/2"NPT 1/2" 5/8" 1-11/16" 80 0.56 80253 2"x2"xl/2"NPT 1/2" 1/2" 1-11/16" 80 0.62 FIGURE 2— FITTING DIMENSIONS (Part 3 of 4) Page 6of6 TFPI9I5 FITTING PART NOMINAL SIZE NOMINAL TAKE-OUT SCHO WEIGHT TYPE NUMBER (TIO) (lb.) BACK-TO-BACK TEE XxYxZ X Y.Z X I/O y~Z 80459 80460 1" x 112' NPTx 1/2' NPT 1" x 1/2" NPTx 1/2" NPT 5/8' 5/6" 1-5/16" 1/16 40 40 0.48 0.46 z I/O I/O BACK-TO-BACK CROSS XXV X Z x W X, V Z, W x T/O 80462 1" x x 112" NPTx 1/2" NPT 5/8" 1-3/16" 40 0.46 Wt 80463 1'xl"xl/2" NPT x1/2"NPT 5/8' 1-5/16" 40 0.47 I/O It l 1/0 - T/O SPRINKLER HEAD X xY X Y ADAPTER 00" ELBOW V I/O 80199 3/4' x 1/2" NPT 9/16" 1" 40 0.20 80198 1"x 112" NPT 3/4" 1-1/4' 40 0.26 91TIOX 80196 1"x3/4"NPT 1-1/16" 1-7/16" 40 0.26 FIGURE 2— FITTING DIMENSIONS (Part 4 of 4) Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoing warranty is made in lieu of any and all other warranties. ex- press or implied, including warranties of merchantability and fitness for a par- ticular purpose. This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ax- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 Fig. 22 - Hanger for CPVC Plastic Pipe Single Fastener Strap Type CUS LISTED Size Range - 3/4" thru 2' CPVC pipe Material - Carbon Steel, Pre-Galvanized Ct' Function - Intended to perform as a hanger to support only CPVC piping used in automatic fire sprinkler systems The product acts as a hanger when tab is upward and the fastener screw is in the horizontal position. Figure 22 . can be installed on the top of a beam but in this situation acts as a guide to the piping which is supported by the beam itself. It is not intended to sup- port CPVC pipe from under a flat horizontal surface such as a ceiling For this type of installation, use the TOLCOTM Fig. 23, Double Fastener Strap for I '. '.., CPVC Piping Fig 22 when inverted with the hanger tab downward can function as a restrainer to prevent the upward movement of the sprinkler head during activation b Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using . ... fasteners supplied with product, or into minimum 20 gauge steel using (1) 114" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features - Fig. 22 incorporates features which protect the pipe and ease installation. The flared edge design pro- tects CPVC pipe from any rough surface. It is easily attached to the building structure using the special UL Listed hex head self threading screw furnished with the product, this is the minimum size fastener acceptable. It is recommended that rechargeable electric drills fitted with a hex socket attachment to be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been know to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and CPVC pipe size. Dimensions • Weights cpvc Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 2Vi 11/16 We 5½ 5/16 9 211/16 17A6 We 6 5/16 9 1¼ 31/16 1¼ 1Y16 6½ 5/16 11 116 39'e 1Y4 We 7 5/16 12 2 3Y4 2¼ 131e 8 5/16 15 OFFiCE1MANUFACTURiNG FACILITY • 1315 SAMPSON AVE.. CORONA, CA 92879 • P11: 951.737.5599 • FAX: 951.737,0330 CUSTOMER SERVICE • 800.786.5266 www.tolco.com Fig. 23 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type C®US USTED Size Range - 3/4" thru 2" CPVC pipe Material - Carbon Steel, Pre-Galvanized Function - Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 23 can also be installed on the side of a beam. The Fig. 23 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1" tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Features - Fig. 23 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. It also incorporates snap restrainers allowing easier and faster installation. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installa- tion tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pre-drilling of a pilot hole in wood is required. Finish - Pre-Galvanized Order By - Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • We CPVC Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 3¼ 1910 1316 516 5/16 - 9 1 3% 11Y16 iVie 6 5/16 9 1¼ 431e 2352 1316 6½ 5116 11 1½ 431e 2352 1316 7 5/16 12 2 4% 231e 1316 8 5/16 15 OFFICE/MANUFACTURING FACIUTY • 1375 SAMPSON AVE. . CORONA, CA 92879. PH: 951.737.5599. FAX: 951.737.0330 CUSTOMER SERVICE • 800,786.5266 www.tolco.com Fig. 24 - Hanger for CPVC Plastic Pipe Double Fastener Strap Type - Side Mount cus LISTED Size Range - 3/4" thru 2' CPVC pipe Material - Carbon Steel, Pie-Galvanized Function - Intended to perform as a hanger/restrainer to support only CPVC piping used in automatic fire sprinkler systems. Can be installed on the top or on the bottom of a beam. The Fig. 24 can also function as a restrainer to prevent the upward movement of the sprinkler head during activation. Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL) to support fire sprinkler piping. May be installed in wood using fasteners supplied with product, or into minimum 20 gauge steel using (2) 1/4" x 1' tek type screw. Meets and exceeds the requirements of NFPA 13, 13R and 130. Features - Fig. 24 incorporates features which protect the pipe and ease installation. The flared edge design protects the CPVC pipe from any rough surface. Easily attaches to the building structure using the two UL Listed hex head self threading screws* furnished with the product. It is recommended that rechargeable electric drills fitted with a hex socket attachment be used as installation tools. No impact tools (such as a hammer) or impact fasteners (such as drive screws or nails) are allowed. Damage has been known to result from installations using impact type tools. No pie-drilling of a pilot hole in wood is required. Finish - Pie-Galvanized Order By - Figure number and pipe size * Hardened hex head self threading screw is furnished with the product and is the minimum fastener size acceptable. Dimensions • Weights cpvc Max. Hanger Fastener Hex Approx. Pipe Size A B C Spacing (Ft.) Head Size Wt./100 3/4 2V6 15A2 l/16 51h 5/16 9 2% 16 13/16 6 5/16 9 1¼ 3 1½ 1/l6 61h 5/16 11 1½ 3¼ 1% 1/l8 7 5/16 12 2 31¼8 127A2 13/16 8 5/16 15 OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE.' CORONA, CA 92879 • PH: 951.737.5599. FAX 951.737,0330 CUSTOMER SERVICE ' 800.786.5266 www.tolco.com - Manifold Body. Male Thread x Male Thread - - In-Line Chack Valve, String Loaded 2 Water Gaige, SOOPSE Ball Valve Flow Switch with Retard 6 1 90 Street Elbow I* Griñnell® The RESI-RISER fire sprinkler riser is preassem- bled, compact, attractive unit for residential sprinkler risers in NFPA 13,13D and/or 13R systems. Brass construction makes RESI-RISER the ideal choice for use with potable water systems. The manifold portion of the RESI-RISER is manufac- tured from a one piece brass casting, air tested at the factory for leaks. Raised lettering on both sides allows for the unit to be installed to the right or left, and also easily identities the flow direction, and Test and Drain outlets. Two mounting legs are molded onto the manifold, allowing secure fastening to joists. The dedicated flow switch used with RESI-RISER has been tested and approved by its manufacturer, System Sensor. This quality flow switch is UL listed and FM Approved, and contains dual SPOT switches with an adjustable retard time of 0-70 seconds. A slim flow switch and the RESI-RISER's unique design of installing all the components to one side, while molding the mounting legs on the opposite side, gives it the ability to be installed within 2x4 wood frame construction. An optional pressure relief valve is available for use with CPVC systems, or in accordance with NFPA 13 Section 3-1.2, which requires a pressure relief valve on gridded systems. Technical Data Sizes: 1", 1-1/4", 1-1/2" and 2" Style: Thread x Thread Listings: Flow Switch and Pressure Gauge are UL Listed Finish (Riser Body): Cast Brass Water Pressure Gauge: 300 Psi Optional Accessories: 175 PSI Rated Pressure Relief Valve Flow Switch without Retard For more information, call your Grinnell Representative today, or visit us on the Internet at: http:I/grinnell.com A tqca INTERNATIONAL LTD. COMPANY Corporate Marketing Services Grinneff 1100 West Thomdale Avenueltasca, IL 60143 Phone: (630) 787-6100, Fax: (630) 787-6111 Grinnell Supply. Sales & Manufacturing, Executive Offices 3 Tyco Park, Exeter, NH 03833 Internet Address: http://www.grinneli.com .SINGAPORE NETHERLANDS (65)861-1655, Fax (65) 815143`12 Enschede: MALAYSIA (31)53-428-3434, Fax (31) 53428-3420 -Petaling Jays: UNITED KINGDOM (60) (3) 573-2773, Fax (60) (3) 5722755 8tockpórt -(44) 161-429-9730, Fax (44)161-429-9748 'BELGIUM NEW SOUTH WALES Brussels HoxtonParlc : (32)2 7717410, Fix (32)2 770 7312 (02)607-6133. Fax (02) 6084224 GERMANY D43110.Rodgau: (49) 6106.84455, Fax (49)6106.18177 ALBERTA SPAIN Calgary: -(403) 246-0033, Fax (403) 246-0051 Coslada (Madrid): Ediiionton: (03)34 1 669-3906, Fax (03)34 1 669 2018 (463) 452-9841, Fax (403) 452-9873 BRITISH COLUMBIA Delta; (604) 940-1449, Fax (604)940-9878 CORAL GABLES, FLORIDA, USA: Nanalmo: (250) 7%1551, Fax (250).758-1160 (305)448-0059; Fax (305)448-1632 Prince George: BUENOS AIRES, ARGENTINA: (250) 561-1219:Fax (250) 561-7358 54.4-308-6444, Fax 54-1-308-6445 Vancouver City: LUJAN-MENDOZA, ARGENTINA: (604)8756990, Fax (604) 8754&%2 54-61.680642, Fax 54-61-981765 MANITOBA RIO DEJA NEIRO, BRAZIL: Winnipeg: (204) 774-3461, Fax (204) 786.5044 55-25-240.6695,55-21-532.2589 ONTARIO Fax 55-21-2406770 StoneyCreelc SOROCABA-SAO PAULO, BRAZIL: (905)664-9230, Fax (905) 664-9556 -5545-228-3555, Fax 55-15-228-3288, Toronto: @16)251-4171, Fax (416)251-7087 55-15-228-3391 ANTOFAGASTA, CHILE: Samla: (519) 336-7690, Fax (519) 336-1621 8-fl.8, Fax 58-55-27-5624 Sudbury: (705) 671-9600. Fax (705)671-8082 MAIPI] SANTIAGO,- CHILE: QUEBEC 58-2-538-1800, Fax 56-2-538-0050 Montreal: (514)342-2100. Fax (514),342-2177 GUADALAJARA, MEXICO: Ste-Foy: (418) 650-5766, Fax (48) 653-2205 (523)688.0505, Fax (523) 688-1017 SASKATCHEWAN MEXICO tITY, MEXitO: Regina: (306)543-5536, Fax (306) 545.0390 (525) 207-5766, Fax (525)207-7586 Saskatoon: CARACAS, VENEZUELA: (306) 242.6788, Fax (306) 242-5089 - (58-2) 991-77551991-7355, Fax (58-2) 991-6409 - MARA cAIRO,: VENEZUELA: (5261)910526, Fax (5861) 931894 AUCKLAND (09) 827-2290, Fax (09) 827-2288 DISTRIBUTED BY U.S. REGIONAL SERVICE CENTERS CALIFORNIA Fullerton 92831-1600 E. Orangethorpe Ave. (714) 773-1166, Fax (714) 879-2319 SERVICING: Alaska; Arizona; California; Colorado; Hawaii; Idaho; Nevada; Oregon; Utah; Washington; Wyoming ILLINOIS Harvey 60426- 15100 S. Halsted St. (706) 210-9090, Fax (708) 210-9920 SERVICING: Illinois; Indiana; Iowa; Kansas; Kentucky; Michigan; Minnesota; Missouri; Montana; Nebraska; N. Dakota; Ohio-West (Cincinnati); S. Dakota; Wisconsin GEORGIA Norcross 30071 - 6344 Cash Court (770) 662-8177, Fax (770) 662-0284 SERVICING: Alabama; Florida; Georgia; Mississippi; N. Carolina; S. Carolina; Tennessee PENNSYLVANIA Hatboro 19040-4219 -2700 Turnpike Drive (215) 672-3444, Fax (215) 672-4406 SERVICING: Connecticut; Delaware; Maine; Maryland; Massaschusetts; New Hampshire; New Jersey; New York; Ohio-East (Cleveland); Pennsylvania; Rhode Island; Vermont; Virginia; W. Virginia TEXAS Irving 75061 - 2425 E. Pioneer Drive (972) 438-4414, Fax (972) 438-7059 SERVICING: Arkansas; Louisiana; New Mexico; Oklahoma; Texas #127/Printed In USA/RPI I 12.98 /5M /01998 - A tqca INTERNATIONAL LTD. COMPANY MODEL 1 . 011 p !1E I] The AGF Manufacturing Inc. Model 1011 Matches All The Features And Benefits Of Our Model 1000 by Providing Both The Test Function And The Express Drain Function In A Multistory Installation, With The Added Feature Of An Integral Model 7.000 Pressure Relief Valve With Drainage Piping. Available In A Full Range Of Sizes From 3/4" To 2", NPT & BSPT, With All Specifiable Orifice Sizes s/B" /16", 1/2", 11/", 5/8" (ELO), & 3/4" (ESFR). The Model 1011 Complies With The Requirements Of NFPA 13,13P, & 13D, Which Stipulate A Pressure Relief Valve Be Installed On All Gridded Systems And Downstream Of All Pressure Reducing Valves. The Model 1011 Is A Single Handle Ball Valve That Is Lightweight And Compact, Which Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glass, And Is 300 PSI Rated. The Included UL/FM Model 7000 Pressure Relief Valve Features A Flushing Handle And Is Factory Set At 175 PSI, Other Pressure Settings Are Also Available. Designed To Relieve Excess System Pressure Caused By Surges Or Temperature Changes A Well As Solve The Difficult Problem Of Providing The Relief Valve With A Drainage-Piping Outlet. 8/01 The Unit Comes Shipped In A Semi-Assembled State With The Relief Valve And The Bypass Drain Ports Plugged. This Is Done To Ease Pressure Testing The System. 0-A our New q,,0 -V10m G onlbssms 'llThMP MATERIAL LIST PART: MATERIAL HANDLE STEEL STEM ROD BRASS BALI, C.RBRONZE BODY BRONZE VALVE SEAT IMPREGNATED TEFLON INDICATOR PLATE STEEL RELIEF VALVE BRONZE BYPASS FITTINGS BRASS BYPASS 1UBING NYLOBRAID , .6 MODEL 1011 m DRAIN. ®. MODEL 1011 (UL LISTED/FM APPROVED) BRONZE BALL VALVE MODEL 7000 (UL LISTED/FM APPROVED) PRESSURE RELIEF VALVE FACTORY SET AT 175 PSI WITH OTHER SETTINGS AVAILABLE. FRONT VIEW - MODEL 1011 PLAN VIEW. From the February 1, 1999 Edition of NFPA 13: Chapter 4-1.2 Requires ALL GRIDDED SYSTEMS be provided with a relief valves Chapter 5-14.1.2.3 Pequires a relief valve be installed downstream of all pressure-reducing valves ORIFICE SIZES AVAILABLE -Ia, I2, '32, ELO(5/), ESFR(3/4)' DIMENSIONS - INCHES SIZE .OYERAU. LThGIH 1011 1011 A 8 CD EF G H 3/47 7 911C 191.30mm 1 1/2" 37.58mm 2 VIC 55.65mm 3 s/a" 9323mm 3 3/67 85.68mm 1 13/16" 45.30mm 4 /16" 117.12mm 6 3le 162.42mm 1" 7 %&" 191.30m,i 1 1/2" 31.58mm 2 Vie" 55.65mm 35/o7 93.23mm 3 /e" 85.88mm 1 13ia 45.30mm 4 Me 117.12mm 6 3i" 162.42mm 1 1/4" 7 Islie 201mm 1 11/16" 42.70mm 2 'i " 65.36mm 4 1/4" 106.36mm 3 'io" I 82.84mm 1 15/i&" I 50.89nvn 5 she I 141.39mm 5 i 192.28mm 1 i,2" I 8 15/fl" 226.68mm 1 13/16" 45.50mm I 3 1/4" 81.50mm 5 1/16" 127mm 3 7/8" 99.18mm 2 '8" 06.97mm I 14" 206.63mm 1273.60mm 10 'ie" 211 8 15/16" 226.68mm 1 1316" 45.50mm 3 1/4w 81.50mm 5 %67 121mm I 3 a" 99.18mm 2 %"8 66.91mm I 1/4fl 206.63mm 1273.60mm 10 'a" 'Available on 1 /4' to 2' size units only. UL USIING EX4019(N) & EX45$3(N) AGF MANUFACTURING COMPANY I 100 Quaker Lane Malvern, PA 19365 USA I Telephone: (610) 240-4900 Fax: (610) 240-4906 www.testandraln.com I MASS IN U.S.A. JOB NAME: ARCHITECT: ENGINEER: CONTRACTOR: 66/30/2065 14:57 7146321614 STARFIRE PAGE 67 C P01T 81Z VS VANE TYPE WATERFLOW The Symbo/IofProte,tion ' ALARM SWITCH WITH RETARD ... UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA _____ Accepted, CE Marked Service Pressure: Up to 450 PSI (31 BAR) __ __ . . _________ _____________ Minimum Flow Rate for Alarm: 10 GPM (30 1pm) Maximum Surge: 18 FPS (10 m/s) Contact Ratings: Two sets of SPOT (Form C) 15.0 Amps at 1251250VAC ________________________ 2.0 Amps at 3OVDC Resistive Conduit Entrances: Two knockouts provided for 112" conduit Environmental Specifications: Suitable for Indoor or outdoor use with factory installed gasket and die-cast housing. '• ç •.••• . NEMA 4/IP54 Rated Enclosure - use with appropriate - . conduit fitting. Temperature Range: 40"F/120F, 4,5"C149°C Non-corrosive sleeve factory installed In saddle. Caution: This device Is not Intended for applications in explosive . environments. •, SizesAvaijaWe: Steel Pipe schedules lO thru 4O, sizes 2" thru 8" ' t• BS 1387 pipe 50mm thru 200mm . -. '"' . Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 U.S. Pat. No. 2921989 One or two family dwelling NFPA-13D Canadian Pat. No. 1009680 Residential occupancy up to four stories NFPA-13R Other Patents Pending National Fire Alarm Code NFPA-72 Potter Electric, Rd., 1990 Optional: Cover Tamper Switch Kit, Stock No. 0090018 GENERAL INFORMATION . INSTALLATION: See Fig-2 The Model VSR-F Is a vane type wterfIow switch for use on wet These devices may be mounted on horizontal or vertical pipe. sprinkler systems. It Is UL Listed g nd FM Approved for use on On horizontal pipe they should be installed on the top side of the steel pipe; schedules 10 through 41, sizes 2" thru 8" (50mm thru pipe where they will be accessible. The units shoul not be in- . . 200mm). stalled within 6" (15cm) of a fitting which changes the direction of LPC approved sizes are 2" thru 8" (50mm thru 200mm). the waterfiow or within 24" (60 cm) of a valve or drain. The unit may also be used as a se :tjoflal waterflow detector on Drain the system and drill a hole in the pipe using a circular saw large systems. In a slow speed drill. The 2" (60mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1/4" + '118" - 1116" (33mm The unit contains two single pole] double throw, snap action ±2mm). All other sizes require a hole with a diameter of 2" ±1/8k switches and an adjustéble, instantly recycling pneumatic (50mm ±2mm). tard. The switches are actuated when a flow of 10 gallons per minute (38 1pm) or more occurs dc wnstream of the device. The Clean the Inside pipe of all growth or other material for a dis- flow condition must exist for a perkd of time necessary to over- tance equal to the pipe diameter on either side' of the hole. • ', come the selected retard period. . Roll the vane so that It may be lnserted'into the hole:, do not bend ENCLOSURE: The unit Is ionclos6d In a general purpose, die- or crease it. insert the vane so that the arrow on the saddle cast housing. The cover is held in place with-two tamper reals- points, in the direction of the waterflow. Install the saddle strap tant screws which require a speck I key for removal. A field i. and tighten nuts alternately to. an eventual 50 ft-IDs. (68 n-rn) of stalIble cover tamper switch Is a 'atiable. as an option which torque (see Fig. 2). The vane must not rub the inside of the.pipo may be used to indicate unauth9r17 d removal of the cover. See or bind in any way. - bulletin no. 6400775 for Installatiorli instruátlàns of this switch. Specifications subject to change without notice. Potter Eiectric Signal Company 2081 Jm19 Rod, St. Louis, MO, 62146-4161Phone; 800-225-3936/Canada 888-88-1833 • www.pottejsional.com PRINTED IN USA - MKT. #8800001 -REV LI - PAGE 1 OF 2 - MPG. #5400761 -12/01 Starfire. Inc., . 191 N. Kraemer Blvd. . - : naheirnCA 92808 00 NOT I.AVC COVER OFF FOR EXTENDED PERIOD OF TIME FIG. I KNOS (Ern4tR 0lRCTIoN) .AY. USE THE MINIMUM tCESSARr to PREVENT srnwo is USUALLY FACTORY IS SET To TA 1IPIPE! 1ZE HOLE SIZE I2 t4 2 1/2" 1/4 .i.I/8" -I/IS" [(5OnTI 4 to 65-0)(3rnm 2mm) I ." t a" 2 10 200mm) aomm A.2nrn) -. TIN" NUTS ALTERNATUY.TO AN EVENTUAl. 50F1.-LOS (Ba n—m) OF TORQUE (BLACK) N.C. MOUNT ON FIRE 50 ARROW ON SADDLE POINTS IN DIRECTION OF WAIERFLOW ROLL PADDLE IN opposrrE oicnoi OF WATCRFLOW APPROX. RETARD SETTINGS (I1 srcs.) S 1 A 8 C 0 Ic 0 tO-20 20-40 .33-0* 30-70 JN0_00 DIRECTION OF WATERFLOw 86/36/2005 14:57 7146321614 V SI P PQT.T-E e Symbol of. rated STARFIRE PAGE 08 VSRONF VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD FIG. I. SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL CAUTION: An uninsulated section of a single conductor shOuld not be looped around the termi- nal and serve is two sepa- rate connections. The wire must be severed, thereby providing supervision áf the connection In the event that the wire becomes dislodged from under the terminal. FIG. 3 TYPICAL CONNECTIONS NOTES: The Model VSR-F has two switches, one can be used to operate a central station; pro- prietary or remote signaling unit, white the other contact is used to operste a local audible or visual annunciator. A condition of LPC Approval of this product is that the electri- cal entry must be sealed to exclude moisture. For supervised circuits see "Switch Terminal Connec- tions" drawing and caution note (Fig. 1). FIG.4 To remove knockouts: Place screwdriver at edge of knock- outs, not in the center. 2 SXTO INU.Y CN (bN QW= ON SLOAN .IdI iiç ON 1) ONTI 200 FaA 201 OLOOW 0of04. C 00N?C19 ORc.qm II b. MOL .OTON4. 1 APPLICATION WARNING! Due to the possibility of unintended d that are monitoring wet pipe sprinkler chemical suppression systems. TESTING The frequency of Inspection and testli accordance with applicable NFPA Co quarterly or more frequently). If provided, the inspectors test valve, test purposes. If there are no provisic VSR-F, is not recommended or advise A minimum flow of 10 gpm (38 Lpm) I IMPORTANT NOTICE: Please adviC tested in accordance with the testing I caused by pressure surges, trapped air, or short retrdtirpes, waterfiow switches should not be used as the sole initiating device to discharge AFFFI deluge, or for the model VSR-F and its associated protective monitoring system should be in a. and Standards and/or the authority having jurisdiction (manufacturer recommends Is usually located at the end of the most remote branch line, should always be used for for testing the operation of the flow detection device on the system, application, of the -equired to activate this device, the person responsible for testing of the fire protection system that this system must be PRINTED IN USA . I MKT #8800001 -REV U PAG 2 OF 2 MFG. #6400781 - 12/01 $tarfire inc. 1391 N. Kraemer blvd. Anaheim. CA 92808 Li . ., BRECCO Brecco Corporation - > GAUGES < GAUGES FOR USE WITH WET OR DRY SYSTEMS. GAUGES HAVE A BRONZE BURBON TUBE MOVEMENT IN A STAINLESS STEEL PLATED CASE (UNLESS OTHERWISE NOTED). 3-1/2' DIAMETER. U.L. AND F.M. APPROVED (UNLESS OTHERWISE NOTED). PWt No. Description Box I Case GAAWSS350 AIR I WATER 0- 300 PSI 80 W/ STAINLESS STEEL CASE GM58250 AIR W/ RETARD. 250 PSI 3-1/2" DIA, WI STAINLESS STEEL 80 CASE GAWP200 2" RESIDENTIAL GALRE 300 PSI (NOT U.L. OR F.M. APPROVED) 100 GMWP350 AIR I WATER WI PLASTIC CASE 60 1.800-5434194 . . . Paz: 1.877-474-9248 AR = AS REQUIRED . breccocorp©cacthliflk.net 082000