Loading...
HomeMy WebLinkAbout2017 CASSIA RD; BLDG 3; AS060234; PermitJob Address: 2017 CASSIA RD Permit Type: SPRINK Parcel No: 2150202700 Lot #: 0 Status: ISSUED Applied 9/27/2006 Approved: 9/29/2006 11/3/2020 AS060234 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS060234 Reference No.: Issued: 9/29/2006 PC #: Inspector: Project Title: CASSIA HEIGHTS APTS BLDG. 3 FIRE SPRINKLER INSPECTIONS Applicant: LIFEGUARD FIRE PROTECTION STE F 2605 TEMPLE HEIGHTS DR OCEANSIDE7 CA 760-806-9997 Owner: CITY OF CARLSBAD CALIFORNIA STATE ASSESSED Fees ($) Add'I Fees ($) Total ($) Balance ($) 180 0 180 0 1/1 LIFEGUARD FIRE PROTECTION, INC. .pp- d6 APPROVED APPROVED AS NOTED 1 D NOT APPROVED, RESUBMIT APPROVED ?SfflbMITTED CARLAAAD LIFEGUARD FIRE PROTECTION 2605 TEMPLE HEIGHTS DRIVE SUITE "F" OCEANSIDE, CA 92056 760-806-9997 A5o~ozs+ Job Name : CASSIA HIEGHTS APARTMENTS - BUILDING 3 Building : BUILDING 3 Location : 2017 CASSIA ROAD System Contract Data File : #3UNITCALC.WXF CHECKING IS ONLY FOR CO1FORMAN IITH HL OLSIGN CONCEPT jF THE PROJECT AN",, COMPLIANCE WITH THE INFORMATION GVEN IN THE CONTRACT 000UMENIS. CONTRACTOR IS RESPONSIBLE FON DIMENSIONS TO BE CONFIRMED Atm CORRELATED AT THE JOB IIIE AND FOR COORDINATION OF TH RK OF ALL TRADES. LIFEGUARD FIRE PROTECTION CASSIA HIEGHTS APARTMENTS - BUILDING 3 Page 1 Date 8-17-06 HYDRAULIC DESIGN INFORMATION SHEET Name - CASSIA HIEGHTS APARTMENTS Date - 8-16-06 Location - 2017 CASSIA ROAD Building - BUILDING 3 System No. - Contractor - LIFEGUARD FIRE PROTECTION Contract No. - Calculated By - JEREMIAH BALCH Drawing No. - Construction: ( ) Combustible ( ) Non-Combustible Ceiling Height 81 -0" OCCUPANCY - Ri S Type of Calculation: ( )NFPA Y Number of Sprinklers Flowing: S ( )Other T C )Specific Ruling E 13 Residential ( )l ( )2 Made by ( )NFPA 13R (X)NFPA 13D (X)4 Date N LiStLd Flow at Start Point - 13 Gpm System Type Listed Pres. at Start Point - 9.1 Psi (X) Wet ( ) Dry D MAXIMUM LISTED SPACING 16 x 16 C ) Deluge ( ) PreAction E Domestic Flow Added - 0 Gpm Sprinkler or Nozzle S Additional Flow Added - 0 Gpm Make RELIABLE Model RFC43 I Elevation at Highest Outlet - Feet Size 1/2" K-Factor 4.3 G Note: Temperature Rating 165 F N Calculation Gpm Required 53.10 Psi Required 56.82 @ BR3 Summary C-Factor Used: Overhead Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 8-3-06 Rated Cap. Cap. T Time of Test - 8.40 am 8 Psi Elev. E Static (Psi) - 90 Elev. R Residual (Psi) - 84 Other Well Flow (Gpm) - 1244 Proof Flow Gpm S Elevation - P Location: HYDRANTS LOCATED IN PARKING LOT OF CASSIA HIEGHTS JOB SITE P (SEE SITE PLAN L Source of Information: BILL MARSH AND DARIEN MORAN OF LIFEGUARD FIRE Y Water Supply Curve (C) LIFEGUARD FIRE PROTECTION Page 2 CASSIA HIEGHTS APARTMENTS - BUILDING 3 Date 8-17-06 City Water Supply: Cl - Static Pressure : 81 C2 - Residual Pressure: 75.6 C2 - Residual Flow : 1244 150 140 130 P 120 R 110 E 100 S 90 S80 U 70 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW ( N' 1.85 ) - Dl - Elevation : 8.519 02 - System Flow : 53.0962 D2 - System Pressure : 66.410 Hose (Adj City) Hose ( Demand) 03 - System Demand : 53.0962 Safety Margin : 14.574 - - - Cl Dl Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram LIFEGUARD FIRE PROTECTION Page 3 CASSIA HIEGHTS APARTMENTS - BUILDING 3 Date 8-17-06 13.2 I A t I 13.2 13 1 2 +-B 13.4 3 *-D 1 7.8 13. 4 -E 13.2 5.6 21.3 A +-B 4-C -,D *-E F 26.2 7.8 31.8 21.7 C F O H *-J 53.1 21.7 31.4 TR 53.1 53.1 G J - - 8R34- UG44- SRC4 53.1 53.1 Fittings Used Summary LIFEGUARD FIRE PROTECTION Page 4 CASSIA HIEGHTS APARTMENTS - BUILDING 3 Date 8-17-06 Fitting Legend Abbrev. Name 'A % 1 1% 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 E 90' Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 1 R CPVC Coupling Tee-Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 T 90' Flow Thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 1 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zwd Watts 709DCDA Fitting generates a Fixed Loss Based on Flow Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 1 16.67 4.3 9.4 na 2 16.67 4.3 9.14 na 3 16.67 4.3 9.7 na 4 16.67 4.3 9.88 na A 17.67 9.53 na B 17.67 9.67 na C 17.67 10.16 na D 17.67 10.08 na E 17.67 10.18 na F 17.67 22.7 na C 8.67 42.18 na H 8.67 44.13 na J 8.67 46.53 na TR 8.67 51.42 na BR3 2.0 56.82 na UG4 -3.0 59.03 na SRC4 -3.0 66.41 na 13.18 1.0 9.1 13.0 1.0 9.14 13.4 1.0 9.1 13.52 1.0 9.1 Pressure / Flow Summary - STANDARD LIFEGUARD FIRE PROTECTION Page 5 CASSIA HIEGHTS APARTMENTS - BUILDING 3 Date 8-17-06 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. The maximum velocity is 17.89 and it occurs in the pipe between nodes F and G Final Calculations - Standard LIFEGUARD FIRE PROTECTION Page 6 CASSIA HIEGHTS APARTMENTS - BUILDING 3 Date 8-17-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ** Notes **** Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 13.18 1.101 IE 3.825 4.500 9.398 K Factor 4.30 to 150 1 9.563 13.387 -0.433 A 13.18 0.0315 0.0 17.887 0.563 Vel = 4.44 0.0 13.18 9.528 K Factor= 4.27 2 13.00 1.101 2E 7.65 13.340 9.140 K Factor =4.30 to 150 1 1.0 18.212 -0.433 B 13.0 0.0306 IT 9.563 31.552 0.967 Vel = 4.38 0.0 13.00 9.674 KFactor = 4.18 3 13.40 1.101 1 3.825 11.670 9.704 K Factor =4.30 to 150 IT 9.563 13.387 -0.433 D 13.4 0.0324 0.0 25.057 0.813 Vel = 4.52 0.0 13.40 10.084 K Factor 4.22 4 13.52 1.101 1 3.825 8.750 9.884 K Factor 4.30 to 150 IT 9.563 13.387 -0.433 E 13.52 0.0330 0.0 22.137 0.730 Vel = 4.56 0.0 13.52 10.181 K Factor = 4.24 A 13.18 1.101 1 1.0 3.670 9.528 to 150 0.0 1.000 0.0 B 13.18 0.0313 0.0 4.670 0.146 Vel = 4.44 B 13.00 1.101 1 1.0 3.340 9.674 to 150 0.0 1.000 0.0 C 26.18 0.1120 0.0 4.340 0.486 Vel = 8.82 C -31.81 1.101 2R 2.0 9.830 10.160 to 150 0.0 2.000 0.0 D -5.63 -0.0064 0.0 11.830 -0.076 Vel 1.90 D 13.40 1.101 2R 2.0 6.250 10.084 to 150 0.0 2.000 0.0 E 7.77 0.0118 0.0 8.250 0.097 Vel = 2.62 E 13.52 1.101 2T 19.125 122.830 10.181 to 150 22R 22.0 41.126 0.0 F 21.29 0.0764 0.0 163.956 12.521 Vel = 7.17 0.0 21.29 22.702 K Factor = 4.47 C 31.81 1.101 2T 19.125 53.000 10.160 to 150 6R 6.0 25.126 0.0 F 31.81 0.1605 0.0 78.126 12.542 VeI= 10.72 F 21.29 1.101 2E 7.65 10.830 22.702 to 150 2T 19.125 26.776 3.898 G 53.1 0.4142 0.0 37.606 15.577 Vel = 17.89 G -31.41 1.394 2T 19.046 53.000 42.177 to 150 6R 6.0 25.047 0.0 H 21.69 0.0251 0.0 78.047 1.956 Vel = 4.56 H 0.0 1.394 IT 9.523 73.000 44.133 to 150 13R 13.0 22.523 0.0 1 21.69 0.0251 0.0 95.523 2.393 Vel = 4.56 Finàl Calculations - Standard LIFEGUARD FIRE PROTECTION Page 7 CASSIA HIEGHTS APARTMENTS - BUILDING 3 Date 8-17-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv Notes Point Qt Pf/UL Eqv. Ln. Total Pf Pn 0.0 21.69 46.526 KFactor= 3.18 G 31.41 1.394 IT 9.523 66.000 42.177 to 150 12R 12.0 21.523 0.0 J 31.41 0.0497 0.0 87.523 4.349 Vel= 6.60 J 21.69 1.394 IT 9.523 21.000 46.526 to 150 1 4.762 16.284 0.0 TR 53.1 0.1313 2R 2.0 37.284 4.895 Vel = 11.16 TR 0.0 1.408 1 3.308 6.670 51.421 to 120 IZ 3.308 6.616 2.889 BR3 53.1 0.1889 0.0 13.286 2.510 Vel = 10.94 BR3 0.0 4.1 3E 43.601 8.500 56.820 to 140 0.0 43.601 2.166 UG4 53.1 0.0008 0.0 52.101 0.040 Vel = 1.29 UG4 0.0 4.23 5E 96.116 55.670 59.026 to 150 IT 38.446 138.406 7.270 * Fixed loss = 7.270 SRC4 53.1 0.0006 1 3.845 194.076 0.114 Vel = 1.21 lZwd 0.0 0.0 53.10 66.410 K Factor= 6.52