Loading...
HomeMy WebLinkAbout2020 CASSIA RD; ; FA070091; Permit11/3/2020 FA070091 Permit Data City of Carlsbad Fire Alarm Permit Job Address: 2020 CASSIA RD Permit Type: FALARM Parcel No: 2150210200 Lot #: 0 Reference No.: Permit No: FA070091 Status: ISSUED Applied 12/18/2007 Approved: 12/18/2007 I.ssued: 12/18/2007 PC #: Inspector: Project Title: O'DAY CONSULTANTS SPRINKLER MONITORING PLAN CHECK/INSPECTION Applicant: COSCO FIRE PROTECTION 10695 TREENA ST SAN DIEGO, CA 858-444-2000 Owner: FRANZ FAMILY REVOCABLE TRUST 06-26- 96 P0 BOX 2711 RANCHO SANTA FE CA Fees AdcVI Fees ($) Total ($) I Balance_($) 125 J 0 125 0 1/1 ::g:: (COSCO ::g: Fire Protection FIRE ALARM MONITORING SYSTEM Submittal for: O'Day Consultants Inc 2020 Cassia Road 01, Carlsbad, Ca. 92010 Prepared by: Cosco Fire Protection 10695 Treena St. #105 San Diego, CA 92131 (858) 444-2000 5104B Fire Control Communicator The speed, reliability and value of digital communications from the company you can trust As pioneers in digital fire technology, Silent Knight delivers superior systems at an outstanding value. Our 5104B Fire Control Communicator has become the industry standard by proving itself in years of field-tested operation. This six-zone fire control communicator provides fast, reliable digital communication of fire and trouble conditions.. It transmits via ordinary phone lines - eliminating the need for expensive leased line arrangements. Use it as a stand-alone, or incorporate it into your existing system. Why spec any other digital communicator? Go with the industry standard - the 5104B Fire Control Communicator from Silent Knight. For more information, please call 1-800-446-6444, or in Minnesota, call (763) 493-6435. S Model 5104B the central station. If one of the Fire Control Communicator telephone lines faults for more than The Silent Knight Model 5104B is a six-zone fire control communicator providing digital fire reporting over ordinary telephone lines, eliminating the need for costly leased lines. It's UL 864 and NFPA 72 approved for monitoring local evacuation controls. As a stand-alone unit, it can be used to monitor: Sprinkler systems for waterflow, supervisory, and gate valve tamper conditions. Automatic fire detection systems for structures that are not required to have a fire alarm system but want property protection (e.g. to call the fire department after hours). Monitors dry contact alarms, trouble and supervisory outputs, then transmits a separate code for each. The Model 5104B is fully supervised. Its microprocessor constantly runs programs to monitor AC, standby battery, zone inputs and telephone line connections. If a fault condition is detected, it sounds a local trouble audible and reports the condition to bU seconds, it will automatically switch to the other to report the failure. The communicator will signal activation, restoration and trouble conditions on any of six inputs. If an application requires a different input configuration, the individual input styles may be changed by using a Model 7181 Fire Zone Converter Module. The 7181 also allows use of two-wire type smoke detectors, instead of the normal four-wire contact type, for automatic fire detection applications. Features UL 864 Listed as an NFPA 72 Central Station or Remote Station protected premise unit. FM approved. Can be used as a stand-alone or as a Slave DACT. Six fully supervised inputs: one Class A (Style D) input, and five Class B (Style A) inputs. Downloadable for remote programming. Fuseless overload protection with automatic reset circuitry and fault indicators - eliminates the cause of most field calls. Dual phone line interface Automatic self tests every 24 hours with report sent to central station. Reports in SIA and most major communications formats. 60 hours of standby power. Operates on loop start phone lines ahead of the building PBX system. A single, programmable output is provided for alarm or dialer failed conditions (cannot be used for evacuation purposes). SILENT KNIGHT by Honeywe 5104B Fire Control Communicator Specifications Electrical Slave Applications - UL Listed Input: 120 VAC 60 Hz 40 watts Current: Standby 50 mA Alarm 135 mA Stand Alone Applications Input: 120 VAC 60 Hz 40 watts Standby: 12 volt 7 amp hour rechargeable battery Mechanical: Dimensions: 12.25° W x 14.5" H x 3.0' D (31.1cm W x 36.8 cm H x 7.6cm D) Weight: 15 lbs. (6.75 kg) Color: Red Optional Accessories: 5230 Remote Annunciator/Programmer 5561 Download Package 7181 Fire Zone Converter Module 5230 Remote Annunciator (three maximum per system) 7860 Telephone Connecting Cord for RJ31 X Jack (2 required) Load: 60 mA standby 120 mA alarm Indicator Lights (LEDs): Power On (Green) Trouble Silenced (Yellow) Until Trouble is Cleared/Flashing = Supervisory Dialer Failure (Yellow) Telephone Line Fault (2 Red) Inside Cabinet at Li and L2 Inputs Telephone Requirements: FCC Registration #: AC698R-17462-AL-E RINGER EQUIVALENCE 0.013 Type of Jack: RJ31X (2 required) 6712 12 volt, 7AH rechargeable battery Communication Formats: SIA, SK 3/1, Sescoa 3/1, Contact ID, SK 4/2, Radionics BFSK Approvals: UL Listed - UL864/NFPA 72 Central and Remote Supervising Station Fire Alarm System Service. FM Approved CSFM Approved MEA Model 5230 Remote Alphanumeric Annunciator The 5104B can be programmed through the use of the optional Model 5230 Remote Alphanumeric Annunciator. Programming options include: telephone numbers, reporting format, account number, loop response times (electronic retard), test time, output activation, user and installer codes. System programming is stored in a non- volatile EEPROM chip which is reprogrammable hundreds of times. The 5104B accommodates up to three remote annunciators via a four-wire connection. A quick- connect plug allows temporary connection of the annunciator for programming. The Model 5561 SKSS Downloading Package Allows for remote programming and status checking of the 5104. Includes a 3 1/2-inch disk and Silent Knight proprietary modem. Allows the installing company to view the default programming, modify it, and if necessary, troubleshoot the system. Designed to be used on an IBM or compatible PC. The downloading software also contains programs for other Silent Knight downloadable products. 5 1/4-inch disks available upon request. fl Model 5230 5104B Fire Control Communicator 120 VAC 60 Hi UL.-LISTEI) LOCAL FIRE. SILENT KNIGHT CONTROL MODEL i046 6 Charthel CoMmunlealo, Alarm Con4act Model 5230 (opIioiiI} Remote Antwclator 3 n Md. Line W1 To R41 TeL l.ine#2 I2OVAC 60 N Class Input (suparvqø; c>-(D--- Max 5welenllow deJces ae per NFPA 72 Class B Inputs r Gta valve ienper orPtV am—oll co,wad. nGmfty open MODEL 5104B BLOCK DIAGRAM Slave DACT Application SILENT KNIGHT MODEL $104B 6 Channel SiLent Knight Communicator Model $21 410 Remote Annunciato (3 max per system) - _________ Tel, Line 91 1' RJ3IX 1ei E1avvc7AHJ Tel. Line 2 0) Wheelock MS-0104 2-R MODEL 5104B BLOCK DIAGRAM Stand-alone Waterfiow Application 5104B Fire Control Communicator IZOVAC 60 Hi Class A Input ('rv4) SILENT KNIGHT MODEL 51048 & Channel Communicator Silent k,tlht Model 5230 (optional) Romota Annuato (3 max per system) Class B Inputs (supervised) Heat detectors, manual pLlll m41ons and ooiitacttype - smoke dtc*om IZVD TAIl Toll. Line, #1 TeL Line #2 To RJ3IX 'Wheelock MB.GIO12.R (optional) MODEL 51:048 BLOCK DIAGRAM Stand-alone Automatic Fire Detection Application (For Communication Only) ARCHITECT/ENGINEER and send the alarm signal on one or The digital communicator shall provide SPECIFICATIONS both lines without the addition of any a secondary power supply utilizing The contractor shall provide an more equipment. It shall test each rechargeable batteries. The secondary approved digital communicator to telephone line (number) at alternating supply shall be capable of supplying transmit the fire alarm and supervisory 24-hour intervals in accordance with power, under maximum normal load, and trouble signals to a central station. NFPA 72. It shall sound a local trouble for 24 hours for central station or The digital communicator shall be UL signal if the telephone service is proprietary applications or 60 hours for or FM listed for fire reporting to a interrupted for longer than 60 seconds remote supervising station system central station and shall conform to the and it shall transmit a signal indicating application in accordance with NFPA requirements of NFPA 72. the loss of phone line service to the 72. The digital communicator shall provide central station over the remaining phone line. A signal shall also be The communicator shall be able to power and necessary components for transmitted to indicate the restoral of transmit all signals in the Standard SIA format (Security Industry Association). six supervised detection circuits. One phone service. The shall be Class A (Style D) and five shall control/communicator shall be able to The alarm signals transmitted to the be Class B (Style A). The detection report the loss of either phone line central station shall indicate which of circuits shall accommodate sprinkler without regard to which phone line the six zones is in alarm and which flow switches, gate valve supervisory failed first. If both lines fail, a local zones are in trouble. Restoral from switches, thermal detectors and signal shall sound. alarm or trouble shall be capable of contact-type smoke detectors intermixed as desired and permitted by The control/communicator shall have communicating to Silent Knight, and other industry standard receivers. NFPA 72. the ability to send a test signal to the central station every 24 hours. The test The control/communicator shall have signal shall be able to be transmitted at the capability to supervise two a specific time of day or night by telephone lines, seize the phone line setting a program within the panel. SrLEM This document is not intended to be used for installation purposes. We try to MADE IN AMERICA keep our product information up-to-date and accurate. We cannot cover all Form# 350349, Rev B 8/07 KNIGHT specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight ©2007 Honeywell International Inc. le by HcmiQywl 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. www.silentknight.com S C CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0559:114 Page 1 of 1 CATEGORY: Control Unit (Non High-Rise) LISTEE: Silent Knight Security, 7550 Meridian Circle, Maple Grove MN 55369-4927 Contact: Michael Mc Isaac (763) 493-6400 *FAX (763) 391-5464 DESIGN: Model 5104. Provides automatic, manual and waterflow service when used as a central station protective premise unit. Intended to monitor various initiating devices and transmit to a central station receiving unit various preprogrammed alarm and trouble signals. Refer to listee's data sheet for detailed product description, electrical rating and operational considerations. OPTIONS: Refer to listee's data sheet for required/optional accessories. When required, accessories shall be CSFM listed. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. . APPROVAL: Listed control unit for use with separately listed compatible initiating and indicating devices. This control unit does not generate a temporal pattern signal. If the distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 2002 Edition is required, the control unit must be used with appliances that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. This control unit meets the requirements of UL-864, 80' Edition Standards. *Rev. 06-12-2006 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. is Date Issued: JULY 24, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marsha! Program Manager DF-52004 • F-050 FureLi re arms June 10, 2005 BG-12 Series by Honeywell Manual Fire Alarm Pull Stations Section: Conventional Initiating Devices GENERAL The Fire•Lite Alarms BG-12 Series is a cost-effective, fea- ture-packed, non-coded series of manual fire alarm pull stations. It was designed to meet multiple applications with the installer and end-user in mind. The BG-12 Series features a variety of models including single- and dual- action versions. The BG-1 2 Series provides Fire-Lite Fire Alarm Control Panels (FACPs), as well as other manufacturers' controls, with a manual alarm initiating input signal. Its innovative design, durable construction, and multiple mounting op- tions make the BG-12 Series simple to install, maintain, and operate. FEATURES Aesthetically pleasing, highly visible design/color. Attractive contoured shape with light textured finish. Meets ADA 5 lb. maximum pull-force. Meets UL 38, Standard for Manually Actuated Signaling Boxes. Easily operated (single- or dual-action), yet designed to prevent false alarms when bumped, shaken, or jarred. PUSH IN/PULL DOWN handle latches in the down po- sition to clearly indicate the station has been operated. The word "ACTIVATED" appears on the top of the handle in bright yellow, further indicating operation of the sta- tion. Operation handle features white arrows showing basic operation direction, for non-English-speaking persons. Braille text included in finger-hold area of operation handle and across top of handle. Multiple hex- and key-lock models available. U.S. patent-pending hex-lock needs only a quarter-turn to lock/unlock. Station can be opened for inspection and maintenance without initiating an alarm. Product ID label viewable by simply opening the cover; label is made of a durable long-life material. The words "NORMAL" and "ACTIVATED" are molded into the plastic adjacent to the alarm switch (located inside). Four-position terminal strip molded into backplate. Terminal strip includes Phillips combination-head cap- tive 8/32 screws for easy connection to Initiating Device Circuit (IDC). Terminal screws backed-out at factory and shipped ready to accept field wiring (up to 12 AWG/3.1 mm2). Terminal numbers are molded into the backplate, elimi- nating the need for labels. c®us State Fire California Marshal p71500075184 LISTED S711 MEA <@> 67-02-E APPROVED Switch contacts are normally open. Can be surface (with SB-I/O or SB-b) or semi-flush mounted. Semi-flush mount to a standard single-gang, double-gang, or 4" (10.16 cm) square electrical box. Backplate is large enough to overlap a single-gang backbox cutout by up to 1/2" (1.27 cm). Optional trim ring (BG-TR). Spanish version (FUEGO) available (BG-12LSP). Designed to replace the Fire'Lite legacy BG-1 0 Series. Models packaged in attractive, clear plastic (PVC), clamshell-style, point-of-purchase packages. Packag- ing includes a cutaway dust/paint cover in shape of pull station. Fire-Lite® Alarms, System Sensor®, and SpectrAlert® are registered trademarks of Honeywell International Inc. LEXAN® is a registered trademark of GE Plastics, a subsidiary of General Electric Company. I This document is not intended to be used for installation purposes. We try to keep our product I ISO 9001 information up-to-date and accurate. We cannot cover all specific applications or anticipate all I requirements. All specifications are subject to change without notice. I For more information, contact Fire-Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. LNGINEEIIIS & Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. QUALITY SYSTEMS DF-52004 • 06/10/05 - Page 1 of 2 S CONSTRUCTION Cover, backplate and operation handle are all molded of durable polycarbonate material. Cover features white lettering and trim. Red color matches System Sensor's popular SpectrAlerl® horn/strobe series. OPERATION The BG-12 manual pull stations provide a textured finger- hold area that includes Braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking persons. Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag. Resetting the station is simple: insert the key or hex (model dependent), twist one quar- ter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch. SPECIFICATIONS Physical Specifications: pull station SB-I/O SB-b Height 5.5 inches 5.601 inches 5.5 inches (13.97 cm) (14.23 cm) (13.97 cm) Width 4.121 inches 4.222 inches 4.121 inches (10.47 cm) 1 (10.72 cm) (10.47 cm) Depth 1.39 inches 1.439 inches 1.375 inches (3.53 cm) (3.66 cm) (3.49 cm) 52004di,,,tbj Electrical Specifications: Switch contact ratings: gold-plated; rating 0.25 A @ 30 VAC orVDC. ENGINEERS' & ARCHITECTS' SPECIFICATIONS Manual Fire Alarm Stations shall be non-code, with a key- or hex-operated reset lock in order that they may be tested, and so designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key or hex. An operated station shall automatically condition it- self so as to be visually detected as activated. Manual sta- tions shall be constructed of red colored LEXAN® (or poly- carbonate equivalent) with clearly visible operating instruc- tions provided on the cover. The word FIRE shall appear on the front of the stations in white letters, 1.00 inches (25.4 mm) or larger.* Stations shall be suitable for surface mounting on matching backboxes SB-10 or SB-I/O; or semi-flush mounting on a standard single-gang, double- gang, or 4 (10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. *NOTE: The words "FIRE/FUEGO"on the BG-I2LSP shall appear on the front of the station in white letters, approximately 3/4"high. Page 2 of 2 - DF-52004 • 06/10/05 PRODUCT LINE INFORMATION BG-12S Single-action pull station with pigtail connec- tions, hex lock. BG-12SL Same as BG-125 with key lock. BG-12 Dual-action pull station with SPST N/O switch, screw terminal connections, hex lock. BG-12L Same as BG-12 with key lock. BG-12LSP Same as BG-12L with English/Spanish (FIRE/FUEGO) labeling. BG-12LOB Same as BG-12L with "outdoor use" listing. Includes outdoor listed backbox, and seal- ing gasket. BG-12L0 Same as BG-12L with "outdoor use" listing. Does not include backbox. BG-12LA Same as BG-12L with auxiliary contacts. BG-12LPS Same as BG-12L with presignal feature. BG-12LPSP Same as BG-12LPS with English/Spanish (FIRE/FUEGO) labeling. SB-I/O Indoor/outdoor backbox. SB-10 Indoor use backbox. 17003 Key lock. 17007 Hex lock. 1.390' (3.531) Wire Length Strip Gauge 1.000" (2.540) 0.750" (1.905) 5.500" (13.970) (cm) CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0075:184 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE: Fire-Lite Alarm Inc., One Fire-Lite Place, Northford CT 06472-1653 Contact: Brian Reynolds *(203) 484-7161 FAX (203) 484-7309 DESIGN: Models BG-12, BG-12S, BG-12NC, BG-12W, BG-12LW, BG-12WP, BG-12LWP, BG-12L, BG-12LX, BG-12LA, BG-12PS, BG-I2LSP, BG-12SP, BG-I2LR, BG-I2LRA, BG-I2LAO, BG-12LAOB, BG-12-LO, BG-12LOB, BG-12LPS, BG-12LPSP, BG-I2SL, *uTP51 and UT- PS2 fire alarm pull boxes. The BG-12 series is a dual action pull station that has normally open switch contacts. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number and UL label. APPROVAL: Listed as fire alarm pull boxes for use with separately listed compatible fire alarm control units. Models BG-12WP, BG-12W, BG-I2LW and BG-I2LWP are intended for outdoor use when installed with Model WP-10 back box. Models BG-LAOB and BG-12LOB are intended for outdoor use when installed with Model WBB or WP-10 back box. XLF: 7150-0028:199 *Rev. 05-06-05 JEW This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 3, 2007 Listing Expires June 30, 2008 . Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager SYSTEM SENSOR Photoelectric Smoke Detectors System Sensor's i series smoke detectors represent significant advancement in conventional detection. The j3 family is founded on three principles: installation ease, intelligence, and instant inspection. Features Plug-in detector line, mounting base included Large wire entry port In-line terminals with SEMS screws Mounts to octagonal and single-gang backboxes, 4-square backboxes, or direct to ceiling Stop-Drop 'N Lock attachment to base Removable detector cover and chamber Built-in remote maintenance signaling Drift compensation and smoothing algorithms Simplified sensitivity measurement -Wide angle, dual color LED indication Loop testing via EZ Walk feature Built-in test switch Agency Listings LISTED 5911 APPROWD 3011446 72/2-1209:210 approved 290-01 -E approved 2093 Installation ease.The il line redefines installation ease with its plug-in design. This allows an installer to pre-wire the bases included with the heads. The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods, as well as direct mounting with drywall anchors. To complete the installation, il heads plug in to the base with a simple Stop-Drop 'N Lock action. Intelligence. il detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. Two-wire 11 detectors needing cleaning can generate a remote maintenance signal, when connected to the 2W-MOD2 loop test/maintenance module, or to a panel equipped with the il protocol. This signal is indicated by LEDs located at the module and the panel. The SENS-RDR, a wireless device, displays the sensitivityof il detectors in terms of percent per-foot-obscuration. Instant inspection. The il series provides wide-angle red and green LED indicators for instant inspection of the detector's condition: normal standby, out-of-sensitivity, alarm, or freeze trouble. When connected to the 2W-MOD2 loop test/maintenance module or a panel with the P protocol, the EZ Walk loop test feature is available on two-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector. I.-. Arch.tcttivat/Fnnincrinr. c-Peifirafinnc Smoke detector shall be a System Sensor I Series model number ,listed to Underwriters Laboratories UL 268 for Fire Protection Signaling Systems.The detector shall be a photoelectric type (Model 2W-8, 4W-B) or a combination photoelectric/thermal (Model 2WT-B, 4WT-B) with thermal sensor rated at 1 35F (57.2C).The detector shall include a mounting base for mounting to 31/2-inch and 4-inch octagonal, single gang, and 4-inch square back boxes with a plaster ring, or direct mount to the ceiling using drywall anchors. Wiring Connections shall be made by means of SEMS screws. The detector shall allow pre-wiring of the base and the head shall be a plug-in type.The detector shall have a nominal sensitivity of 2.5 percent-per-foot nominal as measured in the DL smoke box. The detector shall be capable of automatically adjusting its sensitivity by means of drift compensation and smoothing algorithms.The detector shall provide dual color LED indication which blinks to indicate power up, normal standby, Out of sensitivity, alarm, and freeze trouble (Model 2WT-B, 4WT-B) conditions. When used in conjunction with the 2W-MOD2 module, 2-wire models shall include a maintenance signal to indicate the need for maintenance at the alarm control panel, and shall provide a loop testing capability to verify the Circuit without testing each detector individually. Operating Voltage Nominal: 1 2/24V non-polarized Minimum: 85V Maximum: 35V Maximum Ripple Voltage 30% peak to peak of applied voltage Standby Current 2-wire: 50 pA maximum average; 4-wire: 50 pA maximum average Maximum Alarm Current 2-wire: 130 mA limited by control panel; 4-wire: 20 mA @12V, 23mA @ 24V Peak Standby Current 2-wire: 100 pA; 4-wire: n/a Alarm Contact Ratings 2-wire: n/a; 4-wire: 0.5 A @ 30V AC/DC Physical Specifications Dimensions (including base) 5.3 inches (127 mm) diameter; 2.0 inches (51 mm) height Weight 6.3 oz. (178 grams) Operating Temperature Range 2W-B and 4W-B: 32°F-120F (0C-49C); 2WT-B and 4WT-6: 32F-100F (0C-37.8°C) Operating Humidity Range 0 to 95% RH non-condensing Thermal Sensor 1357 (57.2CC) fixed Freeze Trouble 2WT-B and 4WT-B only: 41'F (5CC) Sensitivity 2.5%/ft. nominal Input Terminals 14-22 AWG Mounting • ILEDModes LED Mode Green LED 31/'2-inch octagonal back box 4-inch octagonal back box Single gang back box 4-inch square back box with a plaster ring Direct mount to ceiling Power Up Sequence for LED Indication Red LED Condition Duration Power up Blink every 10 seconds Blink every 10 seconds Initial LED status indication 80 seconds Normal (standby) Blink every 5 seconds off Out of sensitivity off Blink every 5 seconds Freeze trouble off Blink every 10 seconds Alarm off Solid Ordering Information 2W-B No 2-wire 130 mA max. limited by control panel 2WT-B Yes 2-wire 130 mA max. limited by control panel 4W-B No 4-wire 20 mA @ 12V, 23mA @ 24V 4WT-B Yes 4-wire 20 mA @ 12V, 23mA @ 24V Accessories 2W-MOD2 2-wire loop test / maintenance module RT Removal / reolacement tool SENS-RDR Sensitivity reader A77-AB2 Retrofit adapter bracket, 6.6 in. (16.76cm) diameter 3825 Ohio Avenue. St. Charles, IL 60174 Phone: 800-SENSOR2• Fax: 630-377-6495 cor,entp,oau ote data sheet CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7272-1653:152 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: System Sensor, Unincorporated Div. of Honeywell Int'l Inc., 3825 Ohio Avenue, St. Charles IL 60174 Contact: Trish Linhart (630) 377-6580 ext. 1185 FAX (630) 377-7245 DESIGN: Models 2W-B, 2WT-B, 4W-B and 4WT-B photoelectric type smoke detectors. Models 2W-B and 2WT-B are 2-wire and model 4W-B and 4WT-B are 4-wire detectors. Models 2WT-B and 4WT-B employ a thermistor type heat sensor (1350 F). The heat sensor is are supplemental to the detector and is not intended for use as a required heat detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 8.5-35 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. For vertical wall or ceiling mount. MARKING: Listee's name, model number, electrical rating and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with separately listed compatible fire alarm control units. Suitable for installation in open areas with air velocity range from 0-1000 ft/mm. NOTE: Formerly 7272-1209:210 06-20-05 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 8, 2007 Listing Expires June 30, 2008 Authorized By: MIKE TANAKA, Senior Deputy State Fire Marshal Program Manager