HomeMy WebLinkAbout2020 CASSIA RD; ; AS060230; Permit11/3/2020 AS060230 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2020 CASSIA RD Permit Type: • SPRINK Parcel No: 2150202600 Lot #: 0 Reference No.: Permit No: AS060230 Status: ISSUED Applied 9/22/2006 Approved: 9/27/2006 Issued: 9/27/2006 PC #: Inspector: Project Title: O'DAY MEDICAL OFFICE BLDG. UNDGR FIRE SPRINKLER PLAN CHECK & INSPECTIONS Applicant: Owner: FRANZ-YUT ELCAMINO REAL L L C 2710 LOKER AVE W #100 CARLSBAD CA Fees ($) Add'l Fees ($) Total ($) Balance($) 1 400 0 400 0 TRENCH WIDTH AT TOP OF TRENCH NOT LIMITED TOP OF BACKFILL TO BE SAME \ AS ORIGINAL GROUND AND MATCH ADJACENT UNDISTURBED GROUND - * ..• -. . s..•• • • 4 0. WIDTH S .•••.• ••/. . S I.• ' •.-...i•.: •. •..••. . ..• . .: • •.. . • .. ..• -. . I .e. . .. .. ••.- • ........... a I. -: .:• .. .•. ..• •• TOP OF PIPE - PIPE SPRINGLINE ZONE BEDDING Li Lii -Jo. co 0 Lii 0 01ii o X <U) L) o O() -I- I.- —Lii — I.- 0 U z (.4 Li • I- — (1) BACKFILL TRENCH ZONE WITH NATIVE EARTH BACKFILL OR IMPORTED MATERIAL MARKING TAPE BACKFILL PIPE BASE AND PIPE ZONE WITH IMPORTED SAND HAUNCHING A PIPE OD_ A U -* .- - TRENCH WIDTH IN PIPE ZONE LIMITED A PIPE DIAMETER MIN. MAX. 1" THROUGH 8" 6" 9" io THROUGH 16" 8" - 12- 18" THROUGH 24" 10" 18" 27" THROUGH 36" 12" 24" NO SCALE I 1 BEDDING MATERIAL SECT02223 REVflAPPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT — - - - -- 6-04 ___TYPICAL TRENCH SECTION CITY ENGINEER DATE STANDARD DWG. NO. W 2 I REINFORCING Jr FITTING OR COUPLING. CAP. STEEL DETAIL. 39to MAX. I (0 (RIGID PIPE) ,J J-4f AIliNG O.D. -- çrfl - J NO.4BAR ______ I fli (2EA.TYP.) END CAP BLOCK. Til )A=111/4221/2'. TEE (TOP VIEW). VERTICAL BEND. MIJN _____ o 14 TII II I HORIZONTAL & TEE (SIDE VIEW VERTICAL BEND. 3. CONCRETE SHALL BE 6 SACK, (3250 P.S.I.). A MIN. 3 DAY CURING TIME BEFORE KIflT[C. NOTES: U. HYDROSTATIC TEST. 1. FITTINGS SHALL BE DUCTILE IRON FOR 4. SEE DWG'S. NO. 17 & 18 FOR REDUCER, D.I.P. & P.V.C.; CAST IRON FOR A.C.P. PLUG, & BUTTERFLY VALVE THRUST (CEMENT LINED SHORT BODY). BLOCKS. 2. FOR A.C. PIPE A MIN. 3'-3 TO A 6'-6" MAX. 5. ENGINEER TO PROVIDE CALCULATIONS FOR LENGTH INTO AND OUT OF ALL FITTINGS. THRUST/ANCHOR BLOCK SIZE. ITEM DESCRIPTION SPEC/DWG 1 CONCRETE. _THRUST _BLOCK. _(560-C--3250) 2 POLYETHYLENE.. WRAP.. 3 NO. 4 REINFORCING STEEL. 4 VALVE BOX ASSEMBLY. 5 1 FL X RI OR FL X MJ GATE VALVE. REV. APPROVED DATE CARLSBAD MUNICIPAL WATER DISTRICT CI 6-04 CONCRETE THRUST BLOCKS ciTy ENGINEER DATE STANDARD DWG NO W15 FOR NON-RESTRAINED JOINTS GATE VALVE 1 CHECK'VALVE 1 3 CHECK' VALVE 2 _ - - GATE VALVE 2 IBY SECTION PASS METER w/ DOUBLE CHECK VALVE PUBLIC PRIVATE BY PASS t/11/VAtX PIPING 2 PER PLAN. i', MIN. 4 L..8 MIN.(TYP.) 3 MAX. LL. 1-'-FIN. CR. IL :.. :.':. .• •. •• moo, 6 .'.. PLAN 4 5 CONSUMERS RESPONSIBILITY rTHIS DRAWING SHOWS MINIMUM REQUIREMENTS BY CMWD FOR THE DDCV ASSEMBLY. MODIFICATIONS MAY BE REQUIRED FOR FIRE MARSHAL'S APPROVAL ITEM DESCRIPTION SPEC/DWG 1 APPROVED DOUBLE CHECK VALVE AND DETECTOR ASSEMBLY. 2 FL. BEND TEE _90_ _OR_ _WITH _HOSE_FITTiNGS 2A DEPENDING ON THE PIPELINE MATERIAL SHOWN ON PLANS, 90 BEND CAN .BE FLXPO OR FLXMI 3 4 INCH _THICK _CONCRETE _PAD _(2000_PSI),.__- 4 FL. 10 CA CML&C C-150 STEEL SPOOL WTH S.O.W.O. FLANGE. 5 THRUST _BLOCKING _(3250_PSI)._560-C-3250 6 POLYETHYLENE WRAP 7 6" MINIMUM DIAMETER - REDUCE DIAMETER IN RISER, ABOVE FINISH GRADE WHEN NECESSARY. REV. APPROVED DATE 'CARLSBAD MUNICIPAL WATER DISTRICT - - -- 6-04 ABOVE GROUND DOUBLE CITY ENGINEER DATE STANDARD DWG. NO. W22 CHECK VALVE DETECTOR ASSEMBLY