Loading...
HomeMy WebLinkAbout2023 CASSIA RD; BLDG 4; AS060235; Permit11/3/2020 AS060235 Permit Data City of Carlsbad Sprinkler Permit Job Address: 2023 CASSIA RD Permit Type: SPRINK Parcel No: 2150202700 Lot #: 0 Reference No.: Permit No: AS060235 Status: ISSUED Applied 9/27/2006 Approved: 9/29/2006 Issued: 9/29/2006 PC #: Inspector: Project Title: CASSIA HEIGHTS APTS, BLDG 4 FIRE SPRINKLER INSPECTIONS 112- Luj:; Applicant: LIFEGUARD FIRE PROTECTION STEF 2605 TEMPLE HEIGHTS DR OCEANSIDE, CA 760-806-9997 Owner: CITY OF CARLSBAD CALIFORNIA STATE ASSESSED Fees ($) Add'I Fees ($) Total ($) Balance ($) 180 0 180 0 1/1 APPROVED 4$ BITTED CARLSBA~Fl E DEPARTMENT- Xocoz~~ LIFF=GUARD FIRE, PROTECTIONJN'G. ,IWa D APPROVED 140 APPROVED AS NOTED Lii NOT APPROVED, RESUBMIT CHECKING IS ONLY FOR COFORMA" WITH THE DESIGN CON'EP1 uF THE PRO.EOT AND COMPLIANCE WITH THE INFORMAIlON GIVEN IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR H:ENStONS ro BE CONFIRMED AD CORRELATED AT THE JO SITE AND FOR COORDINATION OE TO 1KQF ALL TRADES LIFEGUARD FIRE PROTECTION 2605 TEMPLE HEIGHTS DRIVE SUITE "F" OCEANSIDE, CA 92056 760-806-9997 Job Name CASSIA HIEGHTS APARTMENTS - BUILDING 4 Building BUILDING 4 Location : 2023 CASSIA ROAD System Contract Data File : #4UNITCALC.WXF LIFEGUARD FIRE PROTECTION Page CASSIA HIEGHTS APARTMENTS - BUILDING 4 Date 8-17-06 HYDRAULIC DESIGN INFORMATION SHEET Name - CASSIA HIEGHTS APARTMENTS Date - 8-16-06 Location - 2023 CASSIA ROAD Building - BUILDING 4 System No. - Contractor - LIFEGUARD FIRE PROTECTION Contract No. - Calculated By - JEREMIAH BALCH Drawing No. - Construction: ( ) Combustible ( ) Non-Combustible Ceiling Height 8'-0" OCCUPANCY - Ri Listed Flow at Start Point - 13 Listed Pres. at Start Point - 9.1 MAXIMUM LISTED SPACING 16 x 16 Domestic Flow Added - 0 Additional Flow Added - 0 Elevation at Highest Outlet - Note: Gpm System Type Psi (X) Wet ( ) Dry Deluge ( ) PreAction Gpm Sprinkler or Nozzle Gpm Make RELIABLE Model RFC43 Feet Size 1/2 K-Factor 4.3 Temperature Rating 165 F S Y S T E M D E S I G N Type f Calculation: ( )NFPA 13 Residential ( )NFPA 13R (X)NFPA 13D Number of Sprinklers Flowing: ( )l ( )2 (X)4 )Other )Specific Ruling Made by Date Calculation Gpm Required 53.10 Psi Required 56.82 @ BR3 Summary C-Factor Used: Overhead Underground W Water Flow Test: A Date of Test - 8-3-06 T Time of Test - 8.40 am E Static (Psi) - 90 R Residual (Psi) - 84 Flow (Gpm) - 1244 S Elevation - Pump Data: Rated Cap. @ Psi Elev. Other Tank or Reservoir: Cap. Elev. Well Proof Flow Gpm P Location: HYDRANTS LOCATED IN PARKING LOT OF CASSIA HIEGHTS JOB SITE P (SEE SITE PLAN L Source of Information: BILL MARSH AND DARIEN MORAN OF LIFEGUARD FIRE Y Water Supply Curve (C) LIFEGUARD FIRE PROTECTION Page 2 CASSIA HIEGHTS APARTMENTS - BUILDING 4 Date 8-17-06 City Water Supply: Cl - Static Pressure : 81 C2 - Residual Pressure: 75.6 C2 - Residual Flow : 1244 150 140 130 P 120 R 110 E 100 S 90 R 60 E 50 40 30 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW (NA 1.85) Dl - Elevation : 8.519 D2 - System Flow : 53.0962 D2 - System Pressure : 66.402 Hose City) Hose ( Demand) 03 - System Demand : 53.0962 Safety Margin : 14.582 - - - - - Cl C2 - S 80 U 70 U Dl • .I I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Diagram LIFEGUARD FIRE PROTECTION CASSIA HIEGHTS APARTMENTS - BUILDING 4 Page 3 Date 8-17-06 13.2 5.6 21.3 A 4-B +-C -.D 4-E i-F 26.2 7.8 31.8 21.7 C i-F i-G i-H i-J 53.1 21.7 31.4 53.1 53.1 G - J i- TR i- BR34- UG5- SRC3 53.1 53.1 Fittings Used Summary LIFEGUARD FIRE PROTECTION Page 4 CASSIA HIEGHTS APARTMENTS - BUILDING 4 Date 8-17-06 Filling Legend Abbrev. Name % 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 2 E 90 Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 G Generic Gate Valve 0 0 0 0 0 I 1 1 1 2 2 3 4 5 6 7 8 10 11 12 R CPVC Coupling Tee-Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0 T 9OFlowThruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 12 Z Generic Flow Switch 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Zwd Walls 709DCDA Filling generates a Fixed Loss Based on Flow If Computer Programs by..Hydratec Inc. Route 111 Windham N.H. USA 03087 1 16.67 4.3 9.4 na 2 16.67 4.3 9.14 na 3 16.67 4.3 9.7 na 4 16.67 4.3 9.88 na A 17.67 9.53 na B 17.67 9.67 na C 17.67 10.16 na D 17.67 10.08 na E 17.67 10.18 na F 17.67 22.7 na G 8.67 42.18 na H 8.67 44.13 na J 8.67 46.53 na TR 8.67 51.42 na BR3 2.0 56.82 na UG5 -3.0 59.03 na SRC3 -3.0 66.4 na 13.18 1.0 9.1 13.0 1.0 9.14 13.4 1.0 9.1 13.52 1.0 9.1 Pressure / Flow Summary - STANDARD LIFEGUARD FIRE PROTECTION CASSIA HIEGHTS APARTMENTS - BUILDING 4 Node Elevation K-Fact Pt Pn No. Actual Page 5 Date 8-17-06 Flow Density Area Press The maximum velocity is 17.89 and it occurs in the pipe between nodes F and G Final Calculations - Standard LIFEGUARD FIRE PROTECTION Page 6 CASSIA HIEGHTS APARTMENTS - BUILDING 4 Date 8-17-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv **** Notes **** Point Qt Pf/UL Eqv. Ln. Total Pf Pn 1 13.18 1.101 IE 3.825 4.500 9.398 K Factor =4.30 to 150 IT 9.563 13.387 -0.433 A 13.18 0.0315 0.0 17.887 0.563 Vel = 4.44 0.0 13.18 9.528 K Factor = 4.27 2 13.00 1.101 2E 7.65 13.340 9.140 K Factor 4.30 to 150 1 1.0 18.212 -0.433 B 13.0 0.0306 IT 9.563 31.552 0.967 Vel = 4.38 0.0 13.00 9.674 KFactor= 4.18 3 13.40 1.101 1 3.825 11.670 9.704 K Factor 4.30 to 150 IT 9.563 13.387 -0.433 D 13.4 0.0324 0.0 25.057 0.813 Vel = 4.52 0.0 13.40 10.084 K Factor = 4.22 4 13.52 1.101 1 3.825 8.750 9.884 K Factor = 4.30 to 150 IT 9.563 13.387 -0.433 E 13.52 0.0330 0.0 22.137 0.730 Vel = 4.56 0.0 13.52 10.181 K Factor = 4.24 A 13.18 1.101 1 1.0 3.670 9.528 to 150 0.0 1.000 0.0 B 13.18 0.0313 0.0 4.670 0.146 Vel = 4.44 B 13.00 1.101 1 1.0 3.340 9.674 to 150 0.0 1.000 0.0 C 26.18 0.1120 0.0 4.340 0.486 Vel = 8.82 C -31.81 1.101 2R 2.0 9.830 10.160 to 150 0.0 2.000 0.0 D -5.63 -0.0064 0.0 11.830 -0.076 Vel = 1.90 0 13.40 1.101 2R 2.0 6.250 10.084 to 150 0.0 2.000 0.0 E 7.77 0.0118 0.0 8.250 0.097 Vel = 2.62 E 13.52 1.101 2T 19.125 122.830 10.181 to 150 22R 22.0 41.126 0.0 F 21.29 0.0764 0.0 163.956 12.521 Vel = 7.17 0.0 21.29 22.702 K Factor = 4.47 C 31.81 1.101 2T 19.125 53.000 10.160 to 150 6R 6.0 25.126 0.0 F 31.81 0.1605 0.0 78.126 12.542 Vel = 10.72 F 21.29 1.101 2E 7.65 10.830 22.702 to 150 2T 19.125 26.776 3.898 G 53.1 0.4142 0.0 37.606 15.577 Vel = 17.89 G -31.41 1.394 2T 19.046 53.000 42.177 to 150 6R 6.0 25.047 0.0 H 21.69 0.0251 0.0 78.047 1.956 Vel = 4.56 H 0.0 1.394 IT 9.523 73.000 44.133 to 150 13R 13.0 22.523 0.0 1 21.69 0.0251 0.0 95.523 2.393 Vel = 4.56 Final Calculations - Standard LIFEGUARD FIRE PROTECTION Page 7 CASSIA HIEGHTS APARTMENTS. BUILDING 4 Date 8-17-06 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. or Ftngs Pe Pv ** Notes Point Qt PfIUL Eqv. Ln. Total Pf Pn 0.0 21.69 46.526 K Factor = 3.18 G 31.41 1.394 IT 9.523 66.000 42.177 to 150 12R 12.0 21.523 0.0 J 31.41 0.047 00 87.523 4.349 Vel = 6.60 J 21.69 1.394 IT 9.523 21.000 46.526 to 150 1 4.762 16.284 0.0 TR 53.1 0.1313 2R 2.0 37.284 4.895 Vel = 11.16 TR 0.0 1.408 1 3.308 6.670 51.421 to 120 IZ 3.308 6.616 2.889 BR3 53.1 0.1889 0.0 13.286 2.510 Vel = 10.94 BR3 0.0 4.1 3E 43.601 12.500 56.820 to 140 0.0 43.601 2.166 UG5 . 53.1 0.0008 0.0 56.101 0.043 Vel = 1.29 UG5 0.0 4.23 5E 96.116 37.000 59.029 to 150 IT 38.446 138.406 7.270 * Fixed loss = 7.270 SRC3 53.1 0.0006 1 3.845 175.406 0.103 Vel = 1.21 IZwd 0.0 0.0 53.10 66.402 K Factor = 6.52