Loading...
HomeMy WebLinkAbout2282 FARADAY AVE; ; AS090029; Permit9/14/22, 5:11 PM AS090029 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS090029 Job Address: 2282 FARADAY AV Permit Type: SPRINK Parcel No: 2120614600 Lot #: 0 Reference No.: Issued: 4/2/2009 PC #: Inspector: Project Title ISIS TWO FIRE INSPECTIONS @ $65/EA Applicant: Owner: BMR-2282 FARADAY AVENUE LLC CIO PARADIGM TAX GROUP 3645 RUFFIN RD #310 SAN DIEGO CA Fees ($) Add'I Fees ($) Total ($) Balance ($) 130 0 130 0 about:blank 1/1 Status: ISSUED Applied 4/2/2009 Approved: 4/2/2009 FILE COPY City of Carlsbad 04-02-2009 Fire Department Permit Permit No: AS090029 Job Address: 2282 FARADAY AV CBAD Permit Type: SPRINK Subtype: COMM Status: ISSUED Parcel No: 2120614600 Lot #: 0 Applied: 04/02/2009 Issued: 04/02/2009 Fire Dept Ref# A5090029 Building Permit#: Entered By: BSW Location: Project Title: ISIS Description: TWO FIRE INSPECTIONS @ $65/EA Contractor: INTEGRATED PROTECTION SERVICES Phone: 760-476-3778 5431 LOS ROBLES Fax: CARLSBAD, CA 92008 Total Fees: $130.00 Total Payments To Date: $0.00 # of Systems 1 # of Additional Risers or Floors Plan Check Fee Additional Plan Check Fee # of Heads 0 Permit Fee Additional Permit Fee Re-Inspection Fee 0 ByPass Meter Fee ByPass Addtl Meter Fee Other Additional Fees TOTAL PERMIT FEES [!] $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $130.00 $0.00 $130.00 NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions''You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. [ii'drautic Summary A501002..1 Job Number: 86014 Report Description: H2 Storage and Ductwork Job ., . Job Number Design bngineer 86014 Gene Janecko Job Name. StateCertiticabon/Lieense Number ISIS 778715 Address I 2282 Farady Avenue AHJ City of Carlsbad Address 2 Job Site H2 Room #102 City State Zip Code Drawing Name Carlsbad CA 860 14_revi _piping. cad System ., . . Remote Area(s) Most Demanding Sprinkler Data Occupancy Job SoRe 5.6 K-Factor 32.00 at 32.653 H2 Storage and Ductwork Hose Allowance At Source Density Area of Application 400.00 0.40gpm/ft2 381 .53ft2 (Actual 381 .53ft2) Additional Hose Supplies Number Of Sprinklers Calculated Coverage Per Sprinkler Node Flow(aom) 13 80.00ft2 Hose At Node 8 50.00 Total Hose Streams 450.00 System Flow Demand Total Water Required (Including Hose pJtcwanne) 497.51 897.51 Maximum Pressure Unbalance In Loops 0.000 n Maximum Velocity Above Ground 22.85 between nodes 57 and 58 Maximum Velocity Under Ground 5.65 between nodes 6 and 7 Volume capacity or Wet Pipes Volume capacity of Dry Pipes 867.57ga1 Supplies . . . . Hose Flow Static Residual @ Flow Available Total Demand Required Safety Margin Node (gpm) (psi) (psi) (gpm) (psi) (gpm) (psi) (psi) 1 400.00 100.000 97.000 900.00 97.015 1 897.51 86.539 10.476 Contractor .. . .' . . ContractorNumber Contact Name Contact Idle 778715 Gus Santerre Name of Contractor Integrated Protection Services Phone 760-476-3778 Extension Address I 5431 Los Robles Drive FAX 760-476-3793 Address 2 E-mail gussanteraol.com City State Zip Code Web-Site Carlsbad CA 92008 www.ipsfire.com ,,©M.E.P.CAD, Inc. AutoSPRINK®VR7v7.0.60 03/30/2009 0:11:00 Page 1 [Summary Of Oufflowing Devices I Job Number: 86014 Report Description: 1-12 Storage and Ductwork Device Actual Flow (gpm) Minimum Flow (gpm) K-Factor (K) Pressure (psi) Sprinkler 414 18.27 10.29 2.3 63.132 Sprinkler 415 18.19 10.29 2.3 62.547 c Sprinkler 501 32.00 32.00 5.6 32.653 Sprinkler 508 30.38 14.82 5.6 29.433 Sprinkler 502 32.15 32.00 5.6 32.961 Sprinkler 506 34.00 14.82 5.6 36.870 Sprinkler 507 31.16 14.82 5.6 30.966 Sprinkler 509 29.48 14.82 5.6 27.714 Sprinkler 510 30.27 14.82 5.6 29.209 Sprinkler 503 32.69 32.00 5.6 34.078 Sprinkler 504 33.06 14.82 5.6 34.852 Sprinkler 513 29.18 14.82 5.6 27.143 Sprinkler 511 32.81 14.82 5.6 34.326 Sprinkler 512 29.93 14.82 5.6 28.570 Sprinkler 505 33.93 32.00 5.6 36.710 Hose 8 50.00 50.00 0 81.115 Most Demanding Sprinkler Data ,©M.E.P.CAD, Inc. 411 AutoSPRINK®VR7v7.0.60 03/30/2009 0:11:07 Page 1 :I[Node Analysis I Job Number: 86014 Report Description: H2 Storage and Ductwork Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 81 4-0 T(5-0) 63.555 80 5-0 T(5-0) 66.811 79 8-0 P0(6-0) 66.446 61 34% LtE(3-0), BOR 71.074 62 4-0 70.665 63 4-1% 70.620 64 4-9 DeIV(12-0) 70.276 65 9-7% 66.150 66 8-0 T(10-0) 66.713 57 10-7 T(5-0) 40.994 58 12-0 T(5-0) 33.700 56 10-7 P0(10-0) 41.984 55 12-0 T(5-0) 31.730 54 10-7 mecT(5-0) 42.074 47 11-1 T(8-0) 37.366 52 10-7 T(5-0) 37.921 53 12-0 T(5-0) 31.108 51 10-7 P0(6-0) 42.209 46 11-1 T(5-0) 39.247 45 10-7 T(15-0) 44.889 42 10-7 LtE(5-0) 53.995 43 3-4 LtE(5-0), BOR 2 53.714 44 10-7 LtE(5-0) 46.492 20 10-11% P0(10-0) 69.820 41 10-7 LtE(5-0) 55.528 19 20-0 P0(12-3%) 65.925 30 20-0 P0(12-3%) 62.213 18 20-0 P0(12-3%) 66.000 29 20-0 P0(12-3%) 63.232 17 20-0 P0(12-3%) 66.157 28 20-0 P0(12-3%) 64.035 16 20-0 P0(12-3%) 66.444 27 20-0 P0(12-3%) 64.759 15 20-0 P0(12-3%) 66.896 26 20-0 P0(12-3%) 65.403 14 20-0 P0(12-3%) 67.485 25 20-0 P0(12-3%) 65.903 13 20-0 P0(12-3%) 68.233 24 20-0 P0(12-3%) 66.273 7 -4-0 83.207 20-0 P0(20-2) 70.457 10 20-0 P0(12-3%) 69.991 23 20-0 P0(12-3%) 66.491 11 20-0 P0(12-3%) 69.902 22 20-0 P0(12-3%) 66.580 6 -4-0 LtE(11-4%) 83.619 12 20-0 P0(12-3%) 69.878 21 20-0 P0(12-3%) 66.604 1-2 CV(-2.000) 83.694 4 1-2 83.724 -4-0 LtE(15-6%) 86.192 -4-0 T(37-10%) 86.536 414 3-0% Spr(-63.132) 63.132 18.27 415 3-9 Spr(-62.547) 62.547 18.19 501 11-1 Spr(-32.653) 32.653 32.00 508 15-0 Spr(-29.433) 29.433 30.38 502 11-1 Spr(-32.961) 32.961 32.15 506 1-0 Spr(-36.870) 36.870 34.00 507 12-0 Spr(-30.966) 30.966 31.16 509 15-0 Spr(-27.714) 27.714 29.48 510 12-0 Spr(-29.209) 29.209 30.27 503 11-1 Spr(-34.078) 34.078 32.69 504 11-1 Spr(-34.852) 34.852 33.06 513 15-0 Spr(-27.143) 27.143 29.18 511 1-0 Spr(-34.326) 34.326 32.81 512 12-0 Spr(-28.570) 28.570 29.93 505 11-1 Spr(-36.710) 36.710 33.93 8 0-6 Hose 81.115 50.00 ,©M.E.P.CAD, Inc. 141 AutoSPRINK®VR7v7.0.60 03/30/2009 0:11:02 Page 1 ' [Hydrauhc Analysis I Job Number: 86014 Report Description: H2 Storage and Ductwork Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary Route ..... BL 1.6100 0=32.00 5.04 Cr120 0.038542 8-0 Pf 0.308 501 502 11-1 11-1 q=32.00 K=5.6 32.653 32.961 Spr(-32.653) 8-0 Pe Pv BL 1.6100 0=64.15 10.11 Cr120 0.139551 8-0 Pf 1.116 502 503 11-1 11-1 q=32.15 K=5.6 32.961 34.078 Spr(-32.961) 8-0 Pe Pv BL 1.6100 0=96.84 15.26 C=120 0.298968 3-0 Pt 3.289 503 47 11-1 11-1 q=32.69 K=5.6 34.078 37.366 Spr(-34.078) T(8-0) 8-0 11-0 Pe Pv BL 2.0670 Q=129.90 12.42 Cr120 0.152451 7-4 Pt 1.880 47 46 11-1 11-1 37.366 39.247 E(5-0) 5-0 12-4 Pe Pv BL 2.0670 0=163.83 15.66 Cr120 0.234195 8-2 Pt 5.426 46 45 11-1 10-7 39.247 44.889 3E(5-0) 15-0 23-2 Pe Pv 0.217 FM 3.0680 0=411.04 17.84 C=120 0.187654 361/ Pt 1.603 45 44 10-7 10-7 44.889 46.492 LtE(5-0) 8-6Y Pe Pv FR 3.0680 Q=411.04 17.84 Cr120 0.187654 Pt 4.079 44 43 10-7 3-4 46.492 53.714 BV(10-0), LtE(5-0), BOR 2 15- 21 -9 Pe Pv 3.143 FR 3.0680 0=411.04 17.84 C=120 0.187654 8-3 Pt 3.425 43 42 3-4 10-7 53.714 53.995 2LtE(5-0) 10-0 18-3 Pe Pv -3.143 FM 3.0680 0=411.04 17.84 Cr120 0.187654 3-2 Pt 1.533 42 41 10-7 10-7 53.995 55.528 LtE(5-0) 5-0 8-2 Pe Pv FM 3.2600 Q=411.04 15.80 C=120 0.139628 63-8 Pt 10.768 41 30 10-7 20-0 55.528 62.213 21-tE(6-81A) 13-5k 7711/ Pe Pv -4.082 BL 2.1570 0=51.12 4.49 C=120 0.022068 143- Pt 3.712 30 19 20-0 20-0 62.213 65.925 P0(12-31/2) P0(12-3%) 24-7K 168-2 Pe Pv CM 3.2600 Q=87.59 3.37 C=120 0.007995 94 Pt 0.075 19 18 20-0 20-0 65.925 66.000 9-4 Pe Pv CM 3.2600 0=131.21 5.04 Cr120 0.016885 94 F-0. 158 18 17 20-0 20-0 66.000 66.157 9-4 Pe Pv CM 3.2600 0=169.00 6.50 C=120 0.026969 10-8 Pt 0.287 17 16 20-0 20-0 66.157 66.444 10-8 Pe Pv CM 3.2600 0=202.36 7.78 Cr120 0.037638 12-0 Pt 0.452 16 15 20-0 20-0 66.444 66.896 12-0 Pe Pv CM 3.2600 0=233.61 8.98 Cr120 0.049091 12-0 Pt 0.589 15 14 20-0 20-0 66.896 67.485 12-0 Pe Pv CM 3.2600 0=265.85 10.22 C=120 0.062355 12-0 Pt 0.748 14 13 20-0 20-0 67.485 68.233 12-0 Pe Pv CM 3.2600 Q=302.06 11.61 C=120 0.078967 8-0 Pt 2.224 13 9 20-0 20-0 68.233 70.457 P0(20-2) 20-2 28-2 Pe Pv FR 4.2600 0=447.51 10.07 Cr120 0.044403 41-9 Pt 2.205 9 8 20-0 0-6 70.457 81.115 LtE(7-11), Hose 7-11 49-8 Pe Pv 8.454 UG 6.4000 0497.51 4.96 Cr140 0.005595 9-E Pt 0.140 8 7 0-6 -4-0 q=50.00 81.115 83.207 LtE(15-61/2) 1561/ 2501/ Pe Pv 1.951 UG 6.0000 0=497.51 5.65 Cr140 0.007661 31-1 Pt 0.412 7 6 -4-0 -4-0 83.207 83.619 2LtE(11-41/2) 2281/ 5391/ Pe Pv UG 6.4000 0=497.51 4.96 Cr140 0.005595 4-6 Pt 2.315 6 5 -4-0 1-2 83.619 83.694 T(51-10), CV(-2.000) 51 -10 56-4 Pe Pv -2.240 UG 6.0650 0=497.51 5.52 C=120 0.009668 3-1 N 0.030 5 4 1-2 1-2 83.694 83.724 3-1 Pe Pv UG 6.4000 0=497.51 4.96 Cr140 0.005595 1' Pt 0.228 4 3 1-2 -4-0 83.724 86.192 GV(5-2), 2LtE(15-6%) 36-3Y 40-9Y Pe Pv 2.240 1,©M.E.P.CAD, Inc. '4AutoSPRINK®VR7v7.0.60 03/30/2009 0:11:03 Page 1 ii [iiydrauIic Analysis - I Job Number: 86014 Report Description: H2 Storage and Ductwork Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary UG 6.0000 0=497.51 5.65 C=140 0.007661 7-01/2 N 0.344 3 2 -4-0 -4-0 86.192 86.536 T(37-101,4) 37-1 1/2 44-11 Pe Pv UG 8.0000 0=497.51 3.18 C=140 0.001887 1-11 Pt 0.004 2 1 -4-0 -4-0 86.536 86.539 S 1-11 Pe Pv Route ..... BL 1.0490 Q=33.93 12.60 C=120 0.345975 2-4 N 2.537 505 46 11-1 11-1 q=33.93 K=5.6 36.710 39.247 Spr(-36.710) T(5-0) 5-1 7-iljPv Pe Route ..... DR 1.0490 0=29.18 10.83 C=120 0.261677 61h/ Pt 2.655 513 53 15-0 12-0 q=29.18 K=5.6 27.143 31.108 Spr(-27.143) 2E(2-0) 4-0 10-1y Pe Pv 1.310 DR 1.0490 0=59.11 21.94 C=120 0.966102 1-5 N 6.199 53 52 12-0 10-7 31.108 37.921 T(5-0) 5-0 6-5 Pe Pv 0.614 AO 1.3800 0=91.92 19.72 C=120 0.575083 1-51/; Pt 4.288 52 51 10-7 10-7 37.921 42.209 P0(6-0) 6-0 751/ Pe Pv -0.000 CM 3.0680 0=247.21 10.73 C=120 0.073256 16-7 Pt 2.680 51 45 10-7 10-7 42.209 44.889 LtE(5-0), T(15-0) 20-0 36-7 Pe Pv Route ..... DR 1.0490 0=29.48 10.94 C=120 0.266761 6-11/ Pt 2.706 509 55 15-0 12-0 q=29.48 K=5.6 27.714 31.730 Spr(-27.714) 2E(2-0) 4-' 10-1Y Pe Pv 1.310 DR 1.0490 Q=59.75 22.18 C=120 0.985492 2-1Y Pt 9.730 55 54 12-0 10-7 31.730 42.074 E(2-0), mecT(5-0) 7- 9101/ Pe Pv 0.614 CM 3.0680 Q=155.29 6.74 C=120 0.030996 4-41/2 Pt 0.135 54 51 10-7 10-7 42.074 42.209 4-41/ Pe Pv Route 5 ..... AO 1.0490 0=29.93 11.11 C=120 0.274371 2- N 2.538 512 53 12-0 12-0 q=29.93 K=5.6 28.570 31.108 Spr(-28.570) E(2-0), T(5-0) 7- 9-Pv Pe Route ..... AO 1.0490 0=30.27 11.24 C=120 0.280049 2-0 Pt 2.520 510 55 12-0 12-0 q=30.27 K=5.6 29.209 31.730 Spr(-29.209) E(2-0), T(5-0) 7-0 9-Pv Pe - .....Route 7 ..... DR 1.0490 0=30.38 11.28 C=120 0.282028 6-6 Pt 2.958 508 58 15-0 12-0 q=30.38 K=5.6 29.433 33.700 Spr(-29.433) 2E(2-0) 4-0 10-6 Pe Pv 1.310 DR 1.0490 0=61.54 22.85 C=120 1.041029 1-5 Pt 6.680 58 57 12-0 10-7 33.700 40.994 T(5-0) 5-0 6-5 Pe Pv 0.614 AO 2.0670 0=95.55 9.14 C=120 0.086367 1-51/2 Pt 0.989 57 56 10-7 10-7 40.994 41.984 P0(10-0) 10-0 11-5Y Pe Pv -0.000 CM 3.0680 0=95.55 4.15 C=120 0.012620 711/ N 0.090 56 54 10-7 10-7 41.984 42.074 71h/ Pe Pv Route ..... AO 1.0490 0=31.16 11.57 C=120 0.295592 2- Pt 2.734 507 58 12-0 12-0 q=31.16 K=5.6 30.966 33.700 Spr(-30.966) E(2-0), T(5-0) 7- 9- Pe Pv Route ..... AO 1.0490 0=32.81 12.18 C=120 0.325147 11-lOIN 7.749 511 52 1-0 10-7 q=32.81 K=5.6 34.326 37.921 Spr(-34.326) E(2-0), 2T(5-0) 12-OI 23-1OI Pe Pv -4.155 Route 10 ..... BL 1.0490 0=33.06 12.27 C=120 0.329751 5-71/ Pt 2.514 504 47 11-1 11-1 q=33.06 K=5.6 34.852 37.366 Spr(-34.852) E(2-0) 2-OI 7-7YPv Pe Route 11 ..... AO 1.0490 0=34.00 12.62 C=120 0.347373 11-1OIN 8.279 506 1-0 10-7 q=34.00 K=5.6 36.870 40.994 Spr(-36.870) E(2-0), 2T(5-0) 12-OI 23-1OI Pe Pv -4.155 Route 12 ..... n... 1&©M.E.P.CAD, Inc. 4.1 AutoSPRINK®VR7v7.0.60 03/30/2009 0:11:03 Page 2 Analysis IHydrauIic Job Number: 86014 Report Description: H2 Storage and Ductwork Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pin Fittings Eq. Length Total Length Summary BL 1.0490 0=18.19 6.75 C=120 0.109185 1-2Pf 1.110 415 81 3-9 4-0 q=18.19 K=2.3 62.547 63.555 Spr(-62.547) 2E(2-0), T(5-0) 9-0 10-2 Pe -0.102 Pv BL 1.0490 0=36.46 13.54 C=120 0.395313 2- N 3.690 81 80 4-0 5-0 63.555 66.811 E(2-0), T(5-0) 7-i 9-4 Pe -0.434 Pv BL 1.3800 0=36.46 7.82 C=120 0.103970 3-i Pf 0.936 80 79 5-0 8-0 66.811 66.446 P0(6-0) 6-i 9-i Pe -1.301 Pv CM 2.0670 0=23.06 2.21 C=120 0.006229 23-9Y N 0.266 79 66 8-0 8-0 66.446 66.713 3LtE(3-0), T(10-0) 19-i 429h/ Pe Pv CM 2.0670 0=36.46 3.49 C=120 0.014535 3- N 0.142 66 65 8-0 9-71/2 66.713 66.150 2LtE(3-0) 6-i 9-: Pe -0.704 Pv CM 3.0680 0=36.46 1.58 C=120 0.002124 410h/ N 2.010 65 64 971/2 4-9 66.150 70.276 CV(-2.000) 4-1Y Pe 2.116 Pv DY 2.4690 0=36.46 2.44 C=120 0.006117 0-0 N 0.073 64 63 4-9 4-11/2 70.276 70.620 DelV(12-0) 12-0 12-0 Pe 0.271 Pv DY 3.0680 0=36.46 1.58 C=120 0.002124 0-0 N 0.000 63 62 4-11/2 4-0 70.620 70.665 0-0 Pe 0.045 Pv DY 2.0670 0=36.46 3.49 C=120 0.014535 0-0 N 0.131 62 61 4-0 341/2 70.665 71.074 BV(6-0), LtE(3-0), BOR 9-0 9-0 Pe 0.278 Pv FM 2.0670 Q=36.46 3.49 C=120 0.014535 8361/ N 2.028 61 20 3-41/2 10-111/2 71.074 69.820 T(10-0), 7LtE(3-0), mecT(10-0), E(5-0), P0(10-0) 56-0 13961/ Pe -3.282 Pv CM 3.2600 0=36.46 1.40 C=120 0.001580 12-3 N 0.030 20 19 10-11% 20-0 69.820 65.925 LtE(6-81/2) 6-8Y 1811h/ Pe -3.925 Pv Route 13 ..... BL 1.0490 0=18.27 6.78 C=120 0.110129 1-8 N 0.844 414 81 3-0% 4-0 q=18.27 K=2.3 63.132 63.555 Spr(-63.132) 3E(2-0) 6-c 7-8j Pe -0.421 Pv Route 14 ..... BL 2.1570 0=32.24 2.83 C=120 0.009404 143-9 N 1.582 25 14 20-0 20-0 65.903 67.485 P0(12-3%) P0(12-3%) 2471/4 168-21/2 Pe Pv Route 15..... CM 3.2600 0=181.65 6.98 C=120 0.030824 12-0 N 0.370 25 24 20-0 20-0 65.903 66.273 12-0 Pe Pv BL 2.1570 0=36.20 3.18 C=120 0.011654 143-7 N 1.960 24 13 20-0 20-0 66.273 68.233 P0(12-3%) P0(12-3%) 24-7Y 168-2Y Pe Pv Route 16 ..... CM 3.2600 0=145.45 5.59 C=120 0.020432 10-8 N 0.218 24 23 20-0 20-0 66.273 66.491 10-8 Pe Pv BL 2.1570 0=49.52 4.35 C=120 0.020806 143-7 N 3.499 23 10 20-0 20-0 66.491 69.991 P0(12-3%) P0(12-3%) 24-7Y 168-2Y Pe Pv CM 3.2600 0=145.45 5.59 C=120 0.020432 2-8 N 0.466 10 9 20-0 20-0 69.991 70.457 P0(20-2) 20-2 22-10 Pe Pv Route 17 ..... CM 2.0670 0=13.40 1.28 C=120 0.002281 98-9Y N0.266 79 66 8-0 8-0 66.446 66.713 6LtE(3-0) 18- Pe 116- Pv Route 18 ..... CM 3.2600 0=359.92 13.83 C=120 0.109209 9-4 N 1.019 30 29 20-0 20-0 62.213 63.232 9-4 Pe Pv BL 2.1570 0=43.62 3.83 C=120 0.016452 143-7 N 2.767 29 18 20-0 20-0 63.232 66.000 P0(12-3%) P0(12-3%) 2471/ 168-2Y Pe Pv Route 19 ..... (, 0 M.E.P.CAD, Inc. 411 AutoSPRINK® VR7 v7.0.60 03/30/2009 0:11:03 Page 3 ' Iydrau11c Analysis I Job Number: 86014 Report Description: H2 Storage and Ductwork Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Upstream Elevation Discharge K-Factor Pt Pn Fittings Eq. Length Total Length Summary _____ CM 3.2600 Q=316.30 12.16 C=120 0.085993 9- Pt 0.803 29 28 20-0 20-0 63.232 64.035 9-4 Pe Pv BL 2.1570 Q=37.79 3.32 C=120 0.012617 143-7 Pt 2.122 28 17 20-0 20-0 64.035 66.157 P0(12-3%) P0(12-31/2) 24-7Y 16821/ Pe Pv Qo .Route20 ..... CM 3.2600 0=278.51 10.71 C=120 0.067957 10-8 Pt 0.724 28 27 20-0 20-0 64.035 64.759 10-8 Pe Pv BL 2.1570 0=33.37 2.93 C=120 0.010021 143-7 Pt 1.685 27 16 20-0 20-0 64.759 66.444 P0(12-3%) P0(12-3%) 24-7Y 168-2Y Pe Pv .Route 21 • CM 3.2600 0=245.14 9.42 C=120 0.053667 12-0 Pt 0.644 27 26 20-0 20-0 64.759 65.403 12-0 Pe Pv BL 2.1570 0=31.25 2.74 C=120 0.008877 143-7 Pt 1.493 26 15 20-0 20-0 65.403 66.896 P0(12-3%) P0(12-31/2) 2471/ 168-2Y Pe Pv .Route22 ..... CM 3.2600 0=95.93 3.69 C=120 0.009460 9-4 N 0.088 23 22 20-0 20-0 66.491 66.580 9-4 Pe Pv BL 2.1570 0=48.16 4.23 C=120 0.019756 143-7 Pt 3.323 22 11 20-0 20-0 66.580 69.902 P0(12-3%) P0(12-3%) 24-7Y 168-2Y Pe Pv CM 3.2600 0=95.93 3.69 C=120 0.009460 9-4 Pt 0.088 11 10 20-0 20-0 69.902 69.991 1 9-4 Pe Pv Go .Route23 ..... CM 3.2600 0=47.77 1.84 C=120 0.002605 9-4 Pt 0.024 22 21 20-0 20-0 66.580 66.604 9-4 Pe Pv BL 2.1570 0=47.77 4.19 C=120 0.019467 143-7 Pt 3.274 21 12 20-0 20-0 66.604 69.878 P0(12-3%) P0(12-3%) 24-7Y 168-2Y Pe Pv CM 3.2600 0=47.77 1.84 C=120 0.002605 9-4 Pt 0.024 12 11 20-0 20-0 69.878 69.902 1 9-4 Pe Pv .Route24 ..... CM 3.2600 Q=213.89 8.22 C=120 0.041701 12- Pt 0.500 26 25 20-0 20-0 65.403 65.903 12-Pv Pe lEquivalent Pipe Lengths of Valves and Fittings (C=120 only) • ( Actual Inside Diameter \487 Schedule 40 Steel Pipe Inside Diameter / - Factor C Value Multiplier • Value Of 100 130 140 Multiplying Factor 0.713 1.16 1.33 150 1.51 . © M.E.P.CAD, Inc. 411 AutoSPRINK® VR7 v7.0.60 03/30/2009 0:11:03 Page 4 [Hydraulic Analysis I Job Number: 86014 Report Description: H2 Storage and Ductwork Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings I Eq. Length I Summary Upstream I Total Length I Pipe Type Legend Units Legend Fittings Legend AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DelV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe Pe Pressure due to elevation difference between indicated points E 90° Elbow UG Underground Pv Velocity pressure at a point in a pipe EE 45° Elbow Eel 11W Elbow Ee2 221/.' Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90° FireLock(TM) Elbow fEE 45° FireLock(TM) Elbow fig Flange FN Floating Node IT FireLock(TM) Tee g Gauge GloV Globe Valve GV Gate Valve Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve P0 Pipe Outlet PrV Pressure Relief Valve PRV Pressure Reducing Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap (kb,, © M.E.P.CAD, Inc. 4 AutoSPRINK® VR7 v7.0.60 03/30/2009 0:11:03 Page 5 [HydrauIic Graph I Job Number: 86014 Reoort Descriotion: H2 Storaae and Ductwork Supply at Node I 150- 135--- 120- 105--- --Static Pressure 100.000 (ED 97.000 90 - Static Pressure 9000 (90%) 86.53 --------- 000 @_.300(90%) 897.51 with hose streams CL j 75j ________ 60 / 45- System demand curve ----/ 30 o__Ir n11L1LL1LJ.LI.JJ.J111111111111111111111111111 111111111 111111111 11111111 liii_III ioo 200 300 400 500 600 700 800 900 1000 Water flow, gpm Hydrauho Graph Supply at Node 1 Static. Pressure 100.000 Residual: Pressure 900.00 @ 97.000 Available Pressure 0 Time of Test 97.015 @ 897.51 System Demand 497.51 @ 86.539 System Demand (including Hose Silowance) 897.51 @ 86.539 1 j©MEP 4Dr Inc. 411 AutoSPRlNK®VR7v7.0.60 03/30/2009 0:11:05 Page 1 !RuserTaa I Job ISIS 2282 Farady Avenue Design Basis Occupancy: Total Sprinklers: Number Of Sprinklers Calculated K-Factor: Orifice Size: Design Density: Average Density: Area of Application: Job Number: 86014 ana uuctwortc H2 Storage and Ductwork 47 13 5.6 0.5 O.40gpm/ft2 1.l7gpm/ft2 381 .53ft2 (Actual 381 .53ft2) Demand At Base Of Riser (BOR 2) Total Demand Flow(gpm): 411.04 Pressure(psi): 53.714 Water Supply Information At Time Of Design Static Pressure(psi): 100.000 Residual Pressure(psi): 97.000 Supply Flow(gpm): 900.00 Total Demand Flow(gpm): 897.51 Total Demand Pressure(psi): 86.539 ,©M.E.P.CAD, Inc. .11, 03/30/2009 0:11:08 Page 2 Conventional I Vertical Sidewall Recessed Pendent Recessed Horizontal Sidewall ASo tqco I Fire & Building Pmducts Technical Services: Tel: (800) 381-9312/ Fax: (800) 791-5500 Series TY-B and TY-FRB Sprinklers Alternate Materials Of Construction Stainless Steel, SMO, and Titanium General Description The Tyco® Series Tv-B and TY-FRB Sprinklers described in this data sheet are corrosion resistant sprinklers de- signed for use in commercial occupan- cies where corrosive atmospheres may exist. The Tv-B with its 5 mm diameter heat sensitive glass bulb is rated standard response, whereas the TY-FRB with its 3 mm diameter heat sensitive glass bulb is rated quick re- sponse. The alternate materials of construction for the Tv-B and TY-FRB Sprinklers, i.e. Stainless Steel, SMO, or Titanium are utilized to extend the life of a sprin- kler beyond that which might be ex- pected of copper alloy sprinklers ex- posed to' corrosive atmospheres. Although corrosion resistant sprinklers have passed the standard corrosion tests of the applicable approval agen- cies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these alternate ma- terials of construction for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fall to operate in a fire situation or cause it to operate prematurely. Upright and Pendent Horizontal Sidewall Page 1 of 16 DECEMBER, 2007 TFPG8O Page 2 of 16 TFP68O chemical to which the sprinklers will be exposed. Pendent and Upright Sprinklers: The pendent and upright sprinklers are standard coverage spray sprinklers available in either 5.6 or 8.0 K-factor. The recessed version is intended for use in areas with a finished ceiling. The two-piece Style 10 (1/2 inch NPT) or Style 40 (3/4 inch NPT) Recessed Escutcheons provide 1/2 inch (12,7 mm) of recessed adjustment or 3/4 inch (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprin- klers must be cut. Conventional Sprinklers: The 5.6 or 8.0 K-factor conventional sprinklers are intended to be installed either pendent or upright, and in either position, they produce a spherical water discharge pattern with approxi- mately 50% of the discharge upwards and approximately 50% of the dis- charge directed downwards Conventional sprinklers are generally used with Ordinary and Extra High hazard Class Systems as defined by the automatic sprinkler system instal- lation rules of the country and authority having jurisdiction. The NFPA permits the use of conventional sprinklers (old style sprinklers) where special con- struction features require a unique water distribution; for fur vaults; or, replacement of similar sprinklers that had been installed prior to 1955. Sidewall Sprinklers: The horizontal and vertical sidewall sprinklers are designed for installation along a wall or side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent and upright sprinklers due to aethectics or building construction considerations, where piping across the ceiling is not desirable. A recessed version of the horizontal sidewall sprinkler can be achieved by using the Style 10 Recessed Escutch- eon. WARNINGS The Series TY-B and TY-FRB Sprin- klers described herein must be in- stalled and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association, in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Numbers Stainless Steel-Standard Response TY8191 - Upright 5.6K, 1/2"NPT TY8291 - Pendent 5.6K, 1/2"NPT TY9191 - Upright 8.0K, 3/4"NPT TY9291 - Pendent 8.01K, 3/4"NPT TY8691- C/UP 5.61K, 1/2" NPT TY9691- C/UP 8.01K, 3/4" NPT TY8391- HSW 5.61K, 1/2" NPT TY8491- VSW 5.6K, 1/2" NPT Stainless Steel-Quick Response TY8181 - Upright 5.6K, 1/2"NPT TY8281 - Pendent 5.6K, 1/2"NPT TY9181 - Upright 8.0K, 3/4"NPT TY9281 - Pendent 8.0K, 3/4"NPT TY8681- C/UP 5.6K, 1/2" NPT TY9681- C/UP 8.0K, 3/4" NPT TY8381- HSW 5.61K, 1/2" NPT TY8481- VSW 5.6K, 1/2" NPT SMO-Standard Response TY8192 - Upright 5.61K, 1/2"NPT TY8292 - Pendent 5.61K, 112"NPT TY8692- C/UP 5.6K, 1/2" NPT TY8392- HSW 5.61K, 1/2" NPT TY8492- VSW 5.61K, 1/2" NPT SMO-Quick Response TY8182 - Upright 5.61K, 1/2"NPT TY8282 - Pendent 5.6K, 1/2"NPT TY8682- C/UP 5.6K, 1/2" NPT TY8382- HSW 5.6K, 1/2" NPT TY8482- VSW 5.61K, 1/2" NPT Titanium-Standard Response TY8193 - Upright 5.61K, 1/2"NPT TY8293 - Pendent 5.61K, 1/2"NPT TY8693- C/UP 5.61K, 1/2" NPT TY8393- HSW 5.61K, 1/2" NPT TY8493- VSW 5.61K, 1/2" NPT Titanium-Quick Response TY8183 - Upright 5.61K, 1/2"NPT TY8283 - Pendent 5.61K, 1/2"NPT TY8683- C/UP 5.61K, 1/2" NPT TY8383- HSW 5.61K, 1/2" NPT TY8483- VSW 5.6K, 1/2" NPT Technical Data Approvals Refer to Table A, B, C, and D. Maximum Working Pressure 175 psi (12,1 bar) Discharge Coefficient K = 5.6 GPM/psi1I2 (80,6 LPM/bar112) K = 8.0 GPM/psi112 (115,2 LPM/barll2) Temperature Ratings Refer to Table A, B, C, and D. Physical Characteristics Stainless Steel The frame is free machining ANC4A Stainless Steel, per BS 3146 PT 2. The Deflector is Type 316L (UNS 31603) Stainless Steel per ASTM A479/479M or BS EN 10088 WN1 .4401/4404. The Compression Screw and Button are Type 316L (UNS 31603) Stainless Steel per ASTM A479/479M or BS EN 10088 WN1 .4404. The Sealing Assembly consists of a Disc Spring that is sealed on both its inside and outside faces with a Teflon*Gasket. The Disc Spring is 1/2 Hard Berylium Nickel (UNS N03360) Gold Plated per MIL G-45204, Type 3, Class 2. The Bulb is Glass. SMO The Frame, Deflector, Compression Screw, and Button are 254 SMO** Duplex Stainless Steel per UNS S31254. The Sealing Assembly con- sists of a Disc Spring that is sealed on both its inside and outside faces with a Teflon* Gasket. The Disc Spring is 1/2 Hard Berylium Nickel (UNS N03360) Gold Plated per MIL G-45204, Type 3, Class 2. The Bulb is Glass. Titanium The Frame is Titanium, Grade 2 per UNS R50400. The Deflector is Tita- nium, Grade 2 per ASTM B265-03. The Compression Screw is Tita- nium, Grade 5 per ASTM B348-03. The Button is Titanium, Grade 2 per ASTM B348. The Sealing Assembly consists of a Disc Spring that is sealed on both its inside and outside faces with a Teflon* Gasket. The Disc Spring is Titanium 6AL/4V Ti per AMS4911J. The Bulb is Glass. * Teflon is a DuPont registered trade- mark. ** 254 SMO is a Avesta Sheffield reg- istered trademark. TFPG8O Page 3 of 16 SPRINKLER MATERIAL MODEL K RESPONSE TYPE TEMP. RATING BULB LIQUID COLOR STAINLESS STEEL SMO I TITANIUM TV-B 5.6 1/2" NPT SR PENDENT and UPRIGHT 135°F/57°C Orange 1,2,3,4 3,4 155°F/68°C 1 Red 175°F/79°C Yellow 200F/93°C Green 286°F/141C Blue 360°F/1 82°C Mauve RECESSED PENDENT* Figure 13 135°F/57°C Orange 1,2 NAS 155°F/68°C Red 175F/79C Yellow 200°F/93°C Green 286°F/141°C Blue TV-B 8.0 3/4" NPT SR PENDENT and UPRIGHT 135F/57*C Orange 1,2,3,4 N/A 155°F/68°C Red 175F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue 360°F/182°C Mauve RECESSED PENDENT* Figure 14 135FI57°C Orange 1,2 155°F/68°C Red 175°F179°C Yellow 200°F/93°C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Loss Prevention Certification Board Approved (LPCB Ref. No. 007q/01 & 007q/02). Loss Prevention Certification Board EC Certificate of Conformity - 0832-CPD-2020. Lloyd's Register Certificate of Fire Approval - SAS F060123. Lloyd's Register EC Type Examination (Module B) Certificate - MED0650147. Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238. * Installed with Style 10 (1/2" NPT) Recessed Escutcheon. NAS: No Approval Status. N/A: Not Available. TABLE A LABORATORY LISTINGS AND APPROVALS SERIES TY-B STANDARD RESPONSE 5.6 & 8.0 K-FACTOR PENDENT AND UPRIGHT SPRINKLERS Page 4 of 16 TFP68O SPRINKLER MATERIAL MODEL K RESPONSE TYPE TEMP. RATING BULB LIQUID COLOR STAINLESS STEEL SMO TITANIUM TV-B 5.6 1/2" NPT QR PENDENT and UPRIGHT 135°F/57°C Orange 1,2,3,4 3,4 155°F/68°C Red 175°F/79°C Yellow 200F/93C Green 286°F/141 °C Blue RECESSED PENDENT* Figure 13 135°F/57C Orange 1,2 NAS 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue TV-B 8.0 3/4" NPT QR PENDENT and UPRIGHT 135°F/57°C Orange 1,2,3,4 N/A 155°F/68C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED PENDENT* Figure 14 135°F/57°C Orange 1,2 155FI68C Red 175FI79°C Yellow 200°F/93°C Green 286°F1141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Loss Prevention Certification Board Approved (LPCB Ref. No. 007q/01 & 007q/02). Loss Prevention Certification Board EC Certificate of Conformity - 0832-CPD-2020. Lloyd's Register Certificate of Fire Approval - SAS F060123. Lloyd's Register EC Type Examination (Module B) Certificate - MED0650147. Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238. * Installed with Style 10 (1/2" NPT) Recessed Escutcheon. NAS: No Approval Status. N/A: Not Available. TABLE B LABORATORY LISTINGS AND APPROVALS SERIES TY-FRB QUICK RESPONSE 5.6 & 8.0 K-FACTOR PENDENT AND UPRIGHT SPRINKLERS TFP68O Page 5 of 16 SPRINKLER MATERIAL MODEL K RESPONSE TYPE TEMP. RATING BULB LIQUID COLOR STAINLESS STEEL I SMO I TITANIUM TV-B 5.6 1/2" NPT SR HORIZONTAL SIDEWALL 135°F/57°C Orange 3,4 155°F/68°C Red 175°F/79C Yellow 200°F/93°C Green 286°F/141°C Blue 360F/182°C Mauve RECESSED HSW Figure 15 135°F/57°C Orange NAS 155F/68°C Red 175°F/79°C Yellow 200F/93°C Green 286°F/141°C Blue VERTICAL SIDEWALL 135°F/57°C Orange 3,4 155°F/68°C Red 175°F/79C Yellow 200°F/93C Green 286°F/141°C Blue 360F/182°C Mauve TV-B 5.6 1/2" NPT QR HORIZONTAL SIDEWALL 135°F/57°C Orange 3,4 155°F/68°C Red 175°F/79°C Yellow 200°F/93°C Green 286°F/141°C Blue RECESSED HSW* Figure 15 135F/57C Orange NAS 155°F/68°C Red 175°F/79°C Yellow 200FI93°C Green 286°F/141°C Blue VERTICAL SIDEWALL 135°F/57°C Orange 3,4 155°F/68°C Red 175°F/79°C Yellow 200°F193°C Green 286°F/141°C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Loss Prevention Certification Board Approved (LPCB Ref. No. 007q/01 & 007q/02). Loss Prevention Certification Board EC Certificate of Conformity - 0832-CPD-2020. Lloyd's Register Certificate of Fire Approval - SAS F060123. Lloyd's Register EC Type Examination (Module B) Certificate - MED0650147. Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238. * Installed with Style 10 (1/2" NPT) Recessed Escutcheon. NAS: No Approval Status. N/A: Not Available. TABLE C LABORATORY LISTINGS AND APPROVALS SERIES TY-B STANDARD RESPONSE AND SERIES TY-FRB QUICK RESPONSE 5.6 K-FACTOR HORIZONTAL SIDEWALL AND VERTICAL SIDEWALL SPRINKLERS Page 6 of 16 SPRINKLER MATERIAL MODEL TYPE TEMP. BULB STAINLESS STEEL I SMO I TITANIUM K LIQUID RESPONSE RATING COLOR I I 135°F/57°C Orange TV-B 5.6 C/UP 155F/68°C Red 175°F/79°C Yellow 1/2" NPT 200°F/93°C Green SR 286°F/141°C Blue 3,4e 360'F/1 82'C Mauv 135F/57'C Orange TV-B 5.6 C/UP 155°F/68°C Red 175°F/79°C Yellow 1/2" NPT 200°F/93°C Green QR 286°F/141°C Blue 135F/57°C Orange TV-B 8.0 C/UP 155°F/68°C Red 175F/79C Yellow 3/4" NPT 200F/93C Green SR 286°F/141°C Blue 3,4 N/A 360'F/1 82'C Mauve 135°F/57°C Orange TV-B 8.0 C/UP 155°F/68°C Red 175°F/79°C Yellow 3/4 NPT 200°F193°C Green QR 286°F/141C Blue NOTES: Listed by Underwriters Laboratories, Inc. (UL). Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL). Loss Prevention Certification Board Approved (LPCB Ref. No. 007q/01 & 007q/02). Loss Prevention Certification Board EC Certificate of Conformity - 0832-CPD-2020. Lloyd's Register Certificate of Fire Approval - SAS F060123. Lloyd's Register EC Type Examination (Module B) Certificate - MED0650147. Lloyd's Register EC (Module D) Certificate of Conformity - MED 0750238. * Installed with Style 10 (1/2" NPT) Recessed Escutcheon. NAS: No Approval Status. N/A: Not Available. TABLED LABORATORY LISTINGS AND APPROVALS SERIES TV-B STANDARD RESPONSE AND SERIES TY-FRB QUICK RESPONSE 5.6 & 8.0 K-FACTOR CONVENTIONAL (C/UP) SPRINKLERS Components: * Temperature rating is 1 - Frame * 4 - Bulb indicated on deflector 2 - Button 5 - Compression or adjacent to orifice 3 - Sealing Screw seat on frame. Assembly 6 - Deflector * 5 4 2 3 CROSS SECTION UPRIGHT ** Pipe thread connections per ISO 7/1 can be provided on special request. 7/16" (11,1 mm) NOMINAL MAKE-IN SSU DEFLECTOR 7/16" I (11,1 mm) I NOMINAL MAKE-IN 2-1/4' ,2 mm) WRENCH 1/2" NPT** FLATS ___ _JT / 2-1/4" I (57,2 mm) 1-1/2" (38,1 mm) SSP DEFLECTOR * PENDENT ESCUTCHEON 1/2" ** PLATE SEATING NPT SURFACE STYLE 10 WRENCH RECESSED FLATS ESCUTCHEON RECESSED PENDENT 2-7/8" (73,0 mm) DIA. I- 2-7/8" (73,0 mm) DIA. SSP DEFLECTOR * PENDENT RECESSED PENDENT 2-1/4" im) SSU DEFLECTOR * 7/16" I NOMINAL I MAKE-IN 2-1/4" JIj\ 1,2 mm) WRENCH FLATS t 1/2" NPT CROSS SECTION UPRIGHT 5 4 2 3 1• TFP6SO Page 7 of 16 FIGURE 1 STANDARD RESPONSE SERIES TY-B STAINLESS STEEL UPRIGHT (TY8191) AND PENDENT (TY8291) SPRINKLERS SMO UPRIGHT (TY8192) AND PENDENT (TY8292) SPRINKLERS TITANIUM UPRIGHT (TY8 193) AND PENDENT (TY8293) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT Components: * Temperature rating is ** Pipe thread connections per ISO 7/1 1 - Frame * 4 - Bulb indicated on deflector can be provided on special request. 2 - Button 5 - Compression or adjacent to orifice 7/16" 3 - Sealing Screw seat on frame. (11,1 mm) ESCUTCHEON STYLE 10 Assembly 6 - Deflector * NOMINAL 1/2" ** PLATE SEATING WRENCH RECESSED MAKE-IN NPT SURFACE FLATS ESCUTCHEON FIGURE 2 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL UPRIGHT (TY8181) AND PENDENT (TY8281) SPRINKLERS SMO UPRIGHT (TYS 182) AND PENDENT (TY8282) SPRINKLERS TITANIUM UPRIGHT (TY8183) AND PENDENT (TY8283) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT Page 8 of 16 TFP68O Components: * Temperature rating is 1 - Frame* 4 - Bulb indicated on deflector 2 - Button 5 - Compression or adjacent to orifice 3 - Sealing Screw seat on frame. Assembly 6 - Deflector * 6 SSU DEFLECTOR * 112' I (12,7 mm) I NOMINAL MAKE-IN 1/4 I -I (57,2 mm) CROSS 3/4 NPT SECTION UPRIGHT ** Pipe thread connections per ISO 7/1 1/2" can be provided on special request. (12,7 mm) ESCUTCHEON STYLE 40 NOMINAL 3/4" ** PLATE SEATING WRENCH RECESSED MAKE-IN NPT SURFACE FLATS ESCUTCHEON r1 'T (58,7 W 1-9/16" (39,7 mm) WRENCH FLATS SSP DEFLECTOR * I-.--- 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT FIGURE 3 STANDARD RESPONSE SERIES TY-B STAINLESS STEEL UPRIGHT (TY9191) AND PENDENT (TY9291) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT Components: - * Temperature rating is 1 - Frame* 4 - Bulb indicated on deflector 2 - Button 5 - Compression or adjacent to orifice 3 - Sealing Screw seat on frame. Assembly 6 - Deflector * 6* SSU DEFLECTOR * 1/2" I (12,7 mm) I NOMINAL MAKE-IN 2 _ 2 1/4" (572 mm) 1*—_____ 3/4 NPT** CROSS SECTION UPRIGHT ** Pipe thread connections per ISO 7/1 1/2" can be provided on special request. (12,7 mm) ESCUTCHEON STYLE 40 NOMINAL 3/4" ** PLATE SEATING WRENCH RECESSED MAKE-IN NPT SURFACE FLATS ESCUTCHEON / 2-5/16" I (58,7 mm) 1-9/16" (39,7 mm) WRENCH FLATS SSP DEFLECTOR * ----- 2-7/8" (73,0 mm) DIA. PENDENT RECESSED PENDENT FIGURE 4 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL UPRIGHT (TY9181) AND PENDENT (TY9281) SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT TFP68O ESCUTCHEON 7/16" (11,1 mm) PLATE SEATING 1/2 ** NOMINAL SURFACE MAKE-IN NPT -r— — —7 4z (57,2 mm) 2-1/4" dit 1- (38, RENCH FLATS Page 9 of 16 ** Pipe thread connections per ISO 7/1 can be provided on special request. 6* Components: 1 - Frame * 5 2-Button 3 - Sealing 4 Assembly 4 - Bulb 2 - Compression Screw 6 - Deflector * * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. 1* SHOWN CROSS SECTION PENDENT SHOWN UPRIGHT FIGURE 5 STANDARD RESPONSE SERIES TY-B STAINLESS STEEL CONVENTIONAL (TY8691) SPRINKLERS SMO CONVENTIONAL (TY8692) SPRINKLERS TITANIUM CONVENTIONAL (TY8693) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT ESCUTCHEON 7/16' (11,1 mm) PLATE SEATING 1/2' ** NOMINAL SURFACE MAKE-IN NPT -r— I-- 2-1/4" (57,2 mm) 1-1/2" t (38,1 mm) RENCH FLATS ** Pipe thread connections per ISO 7/1 can be provided on special request. 6* Components: 1 - Frame * 5 2-Button 3 - Sealing 4 Assembly 4 - Bulb 2 - Compression Screw 6 - Deflector * * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. 1* SHOWN CROSS SECTION PENDENT SHOWN UPRIGHT FIGURE 6 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL CONVENTIONAL (TY8681) SPRINKLERS SMO CONVENTIONAL (TY8682) SPRINKLERS TITANIUM CONVENTIONAL (TY8683) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT Page 10 of 16 TFP680 ESCUTCHEON 1/2 (12,7 mm) ** Pipe thread connections per PLATE SEATING 3/4" ** NOMINAL ISO 7/1 can be provided on SURFACE NPT MAKE-IN special request. Components: 1 - Frame * 2 - Button 2-1/4" 3 - Sealing (57,2 mm) : Assembly f 4 - Bulb 5 - Compression 1-1/2" Screw (38,1 mm) WRENCH 6 - Deflector * N FLATS 3 * Temperature __ 1 * rating is indicated SHOWN CROSS SECTION on deflector or PENDENT SHOWN UPRIGHT adjacent to orifice seat on frame. FIGURE 7 STANDARD RESPONSE SERIES TY-B STAINLESS STEEL CONVENTIONAL (TY9691) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT ESCUTCHEON 1/2" (12,7 mm) ** Pipe thread connections per PLATE SEATING ** NOMINAL ISO 7/1 can be provided on SURFACE MAKE-IN special request. NPT Components: 1-Frame 2 - Button 2-1/4 3 - Sealing (57,2 mm) Assembly 4 - Bulb s - Compression 1-1/2" Screw I (38,1 mm) WRENCH 6 - Deflector * FLATS ', * Temperature 1* rating is indicated SHOWN CROSS SECTION on deflector or PENDENT SHOWN UPRIGHT adjacent to orifice seat on frame. FIGURE 8 QUICK RESPONSE SERIES TY-FRB STAINLESS STEEL CONVENTIONAL (TV9681) SPRINKLERS 8.0 K-FACTOR, 3/4 INCH NPT CENTERLINE OF SPRINKLER WATERWAY TFP68O Page 11 of 16 Components: 1 - Frame * 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * 7 - Ejection Spring * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. DEFLECTC HAT 9/16" WRENCH 1/2' ** (14,3 mm) FLATS NPT I 7/16" I (11,1 mm) I I I NOMINAL I I I MAKE-IN I I 1-1/2" [381 mm) 2-1/4" I - (57,2 mm) - I ESCUTCHEON STYLE 10 PLATE SEATING RECESSED ESCUTCHEON SURFACE 2-7/8" DIA. (73,0 mm) Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The Tyco® Series TY-B and TY-FRB Sprinklers are intended for fire protec- tion systems designed in accordance with the standard installation rules rec- ognized by the applicable Listing or Approval agency (e.g., UL Listing is based on the requirements of NFPA 13). Only the Style 10 or 40 Recessed Escutcheon, as applicable, is to be used for recessed installations. The Series TV-B and TY-FRB Pendent, Conventional, and Vertical Sidewall Sprinklers are only for non-recessed applications. FIGURE 9 STANDARD RESPONSE SERIES TY-B STAINLESS STEEL HORIZONTAL SIDEWALL (TY8391) SPRINKLERS SMO HORIZONTAL SIDEWALL (TY8392) SPRINKLERS TITANIUM HORIZONTAL SIDEWALL (TY8393) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT Page 12 of 16 TFP68O -, 7/16" (11,1 mm) I •-i NOMINAL MAKE-IN 1-1/2" 38,1 mm) 2-1/4" (57,2 mm) ESCUTCHEON STYLE 10 PLATE SEATING RECESSED SURFACE ESCUTCHEON 2-7/8" DIA. (73,0 mm) FIGURE 10 QUICK RESPONSE SERIES TY-B STAINLESS STEEL HORIZONTAL SIDEWALL (TY8381) SPRINKLERS SMO HORIZONTAL SIDEWALL (TY8382) SPRINKLERS TITANIUM HORIZONTAL SIDEWALL (TY8383) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT Components: DEFLECTOR 1Frame * HAT S-.-- 2 - Button 3 - Sealing Assembly 4 - Bulb 5 - Compression Screw 6 - Deflector * 7 - Ejection Spring 9/16' (14,3 mm) CENTERLINE OF SPRINKLER WATERWAY * Temperature rating is indicated on deflector or adjacent to orifice seat on frame. ** Pipe thread connections per ISO 7/1 can be provided on special request. Installation The Series TY-B and TY-FRB Sprin- klers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 inch (1,6 mm) for the 135°F/57°C to 3/32 inch (2,4 mm) for the 360°F/182°C sprinkler. Readjust the position of the sprinkler fitting to suit. The Series TV-B and TY-FRB Pen- dent and Upright Sprinklers must be installed in accordance with the follow- ing instructions. Step IA. Pendent sprinklers must be installed in the pendent position, and upright sprinklers are to be installed in the upright position. Step 2A. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3A. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 16). With reference to Figures 1, 2, 3, and 4 the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series TY-B and TY-FRB Re- cessed Sprinklers must be installed in accordance with the following in- structions. Step lB. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting, Step 2B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 17). With reference to Figures 1, 2, 3, and 4 the W-Type 7 Recessed Sprinkler Wrench is to be applied to the wrench flats. Step 313. After the ceiling has been installed or the finish coat has been applied, slide on the Style 10 or 40 Closure over the sprinkler and push the Closure over the Mounting Plate until it comes in contact with the ceil- ing. The Series TV-B and TY-FRB Con- ventional Sprinklers must be in- stalled in accordance with the follow- ing instructions. Step IC. With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 2C. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 16). With reference to Figures 5, 6, 7, and 8 the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series TV-B and TV-FRB Hori- zontal and Vertical Sidewall Sprin- klers must be installed in accordance with the following instructions. Step ID. Horizontal sidewall sprin- klers are to be positioned in the hori- zontal position with their centerline of waterway perpendicular to the back 6* 4 2 3 1* WRENCH 1/2" ** FLATS NPT temperature ratings. A 1/2 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 7 to 14 ft.lbs. (9,5 to 19,0 Nm). A 3/4 inch NPT sprinkler joint should be obtained with a mini- mum to maximum torque of 10 to 20 ft.lbs. (13,4 (026,8 Nm). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to make-up for insuffi- cient adjustment in the escutcheon plate by under- or over-tightening the TFP68O Page 13 of 16 Components. * Temperature rating ** Pipe thread connections 1 - Frame * 5 - Compression is indicated on per ISO 7/1 can be 2 - Button Screw deflector or adjacent provided on special 3 - Sealing 6 - Deflector * to orifice seat on request. Assembly 7 - Ejection frame. 4 - Bulb Spring ARROW MUST POINT AWAY 7/16" FROM AND BE o ESCUTCHEON (11,1 mm) PERPENDICULAR PLATE SEATING NOMINAL TO THE BACK SURFACE NPT MAKE-IN WALL SURFACE (57 7,2 m ,2 mm) 7 4 3 1-112" I FLATS RENCHI * SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION FIGURE 11 STANDARD RESPONSE SERIES TY-B STAINLESS STEEL VERTICAL SIDEWALL (TY8491) SPRINKLERS SMO VERTICAL SIDEWALL (TY8492) SPRINKLERS TITANIUM VERTICAL SIDEWALL (TY8493) SPRINKLERS 5.6 K-FACTOR, 1/2 INCH NPT Components: * Temperature rating ** Pipe thread connections 1 - Frame * 5 - Compression is indicated on per ISO 7/1 can be 2 - Button Screw deflector or adjacent provided on special 3 - Sealing 6 - Deflector * to orifice seat on request. Assembly 7 - Ejection frame. 4 - Bulb Spring ARROW MUST POINT AWAY 7/16" FROM AND BE ESCUTCHEON (11,1 mm) PERPENDICULAR PLATE SEATING NOMINAL TO THE BACK ** SURFACE MAKE-IN WALL SURFACE i4~ 2-1,4 2-1/4" 1-1/2'RE (57,2 mm) NC J[7 57,2 mm) (38,1 mm) FLATS U-J 1* SHOWN SHOWN CROSS PENDENT UPRIGHT SECTION FIGURE 12 QUICK RESPONSE SERIES TY-B STAINLESS STEEL VERTICAL SIDEWALL (TY8481) SPRINKLERS SMO VERTICAL SIDEWALL (TY8482) SPRINKLERS TITANIUM VERTICAL SIDEWALL (TY8483) SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT wall and parallel to the ceiling. The word "TOP" on the Deflector is to face towards the ceiling. Vertical sidewall sprinklers are to be installed in the pendent or upright po- sition with the arrow on the Deflector pointing away from the wall. Step 211). With pipe thread sealant ap- plied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 311). Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench (Ref. Figure 16). With reference to Figures 9, 10, 11, and 12 the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. The Series TY-B and TY-FRB Re- cessed Horizontal Sidewall Sprin- klers must be installed in accordance with the following instructions. Step IE. Recessed horizontal side- wall sprinklers are to be positioned in the horizontal position with their cen- terline of waterway perpendicular to the back wall and parallel to the ceil- ing. The word "TOP" on the Deflector is to face towards the ceiling. Step 2E. After installing the Style 10 Mounting Plate over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3E. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench (Ref. Figure 17). With reference to Figures 9 and 10 the W-Type 6 Sprinkler Wrench is to be applied to the wrench flats. Step 4E. After the wall has been in- stalled or the finish coat has been ap- plied, slide on the Style 10 Closure over the sprinkler and push the Clo- sure over the Mounting Plate until it comes in contact with the wall. Page 14 of 16 TFP68O Care and Maintenance The Tyco® Series TV-B and TY-FRB Sprinklers must be maintained and serviced in accordance with the follow- ing instructions: NOTES Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shutdown the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified. The owner must assure that the sprin- klers are not used for hanging of any objects; otherwise, non-operation in the event of a fire or inadvertent opera- tion may result. Absence of an escutcheon, which is used to cover a clearance hole, may delay the time to sprinkler operation in a fire situation. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant sprinklers, after the installation has been completed, to verify the integrity of the corrosion re- sistant material of construction. There- after, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the Corrosion resistant material of con- struction, as it may be affected by the corrosive conditions present. The owner is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in ac- cordance with local requirements and/or national codes. 2-7/8 DIA. 5/8±1/4" (73,0 mm) 3/4 (19,1 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4(6,4mm) I - - (57 FACE OF MOUNTING SPRINKLER PLATE FITTING (3,2 m) MOUNTING SURFACE/ CLOSURE SERIES -Bor -FRB 1-5/16"( 33,3 mm) (TY-FRB SHOWN) 13/16" (20,6 mm) FIGURE 13 SERIES TY-B or TY-FRB PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT 2-7/8" DIA. 5/8±1/4" (73,0 mm) I 314" (19,1 mm) I E (15,9±6,4 mm) 2-1/4" DIA. I 1/4" (6,4 mm) I I FACE OF (57,2 SPRINKLER PLATE I FITTING / 1/8" j MOUNTING l m) t \ MOUNTIN SURFACE/ CLOSURE SERIES TY-B or TY-FRB 1-3/8" (34,9 mm) (TY-FRB SHOWN) 7/8" (22,2 mm) FIGURE 14 SERIES TV-B or TY-FRB PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 INCH NPT WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 16 W-TYPE 6 SPRINKLER WRENCH Limited Warranty Products manufactured by Tyco Fire & Building Products are warranted solely to the original Buyer for ten (10) years against defects in material and work- manship when paid for and properly installed and maintained under normal use and service. This warranty will ex- pire ten (10) years from date of ship- ment by Tyco Fire & Building Products. No warranty is given for products or components manufactured by compa- nies not affiliated by ownership with Tyco Fire & Building Products or for RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 17 W-TYPE 7 SPRINKLER WRENCH products and components which have been subject to misuse, improper in- stallation, corrosion, or which have not been installed, maintained, modified or repaired in accordance with applica- ble Standards of the National Fire Pro- tection Association, and/or the stand- ards of any other Authorities Having Jurisdiction. Materials found by Tyco Fire & Building Products to be defec- tive shall be either repaired or re- placed, at Tyco Fire & Building Prod- ucts' sole option. Tyco Fire & Building Products neither assumes, nor author- Page 15 of 16 izes any person to assume for it, any other obligation in connection with the sale of products or parts of products. Tyco Fire & Building Products shall not be responsible for sprinkler system de- sign errors or inaccurate or incomplete information supplied by Buyer or Buyer's representatives. IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS BE LIABLE, IN CONTRACT, TORT, STRICT LI- ABILITY OR UNDER ANY OTHER LE- GAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSE- QUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LABOR CHARGES, REGARDLESS OF WHETHER TYCO FIRE & BUILDING PRODUCTS WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES, AND IN NO EVENT SHALL TYCO FIRE & BUILDING PRODUCTS' LIABILITY EXCEED AN AMOUNT EQUAL TO THE SALES PRICE. THE FOREGOING WARRANTY IS r.J1I4iitIiJa411 va;vyf Ordering Procedure When placing an order, indicate the full product name. Refer to the Price List for complete listing of Part Num- bers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (Specify Model/SIN), (Specify Standard Response or Quick Re- sponse), (specify K-factor), (specify temperature rating), (specify Pendent Upright, C/UP, HSW, or VSW) Sprin- kler with (specify type material: Stain- less Steel, SMO, or Titanium), P/N (specify from Table E). Recessed Escutcheon: Specify: Style (10 or 40) Recessed Escutcheon with (specify material or finish*), P/N (specify). *Refer to Technical Data Sheet TFP770. Sprinkler Wrench: Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387. Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001. TFP68O blö±114 4 (15,9±6, mm) MOUNTING FACE SPRINKLER SURFACE FITTING CLOSURE - __________ 2-7/8 DIA. SERIES TY-B 1 (73,0 mm) OR TY-FRB 2-1/4" DIA. (57,2 mm) PLATE (3,2 mm) 1-5/16(33,3mm) 3/4(19,1 mm) 13/16" (20,6 mm) 1/4(6,4mm) FIGURE 15 SERIES TY-B or TY-FRB HORIZONTAL SIDEWALL SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 INCH NPT Page 16 of 16 TFPG8O P/N 57-XXX-O-XXX-SUFFIX I SR - Standard Response 570 TV-B 5.6K UPRIGHT SR 590 TY-B 8.0K UPRIGHT SR 571 TV-B 5.6K PENDENT SR 591 TV-B 8.0K PENDENT SR 573 TV-B 5.6K C/UP SR 593 TV-B 8.0K C/UP SR TEMPERATURE RATING 135 135°F/57°C 155 155°F/68°C 175 175°F/79°C 200 200°F/93°C 286 286°F/141°C 360 360°F/1 82C TV-B Only MATERIAL None Stainless Steel M SMO (5.6 K Only) I Titanium (5.6 K Only) I 578 I TV-B 5.6K HSW SR I 575 I TV-B 5.6K VSW SR QR - Quick Response 370 TV-B 5.6K UPRIGHT QR 390 TV-B 8.0K UPRIGHT QR 371 TV-B 5.6K PENDENT QR 391 TV-B 8.0K PENDENT QR 373 TV-B 5.6K C/UP QR 393 TV-B 8.0K C/UP QR I 378 I TV-B 5.61K HSW QR I I 375 I TV-B 5.6K VSW QR I TABLE E PART NUMBER SELECTION SERIES TY-B AND TY-FRB SPRINKLERS ALTERNATE MATERIALS OF CONSTRUCTION © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446