HomeMy WebLinkAbout430 TAMARACK AVE; ; FPR2019-0171; Permiti I1IikIi
- I
Print Date: 08/16/2022 Permit No: FPR2019-0171
Job Address: 430 TAMARACK AVE. CARI$BAD, CA 92008-4127 Status: Closed - Finaled
Permit Type: FIRE-Construction Residential Work Class: Single Family Fire Sprinkl
Parcel #: 2042804505 Track #: Applied: 08/29/2019
Valuation: $0.00 Lot #: Issued: 09/24/2019
Occupancy Group: Project #: Finaled Close Out: 04/22/2020
#of Dwelling Units: Plan #:
Bedrooms: Construction Type: Final Inspection:
Bathrooms: Orig. Plan Check #: INSPECTOR: Salcedo, Felix
Plan Check #:
Project Title:
Description: TAMARACK BEACH HOMES -NEW 13D SYSTEM FOR 5 SFD DETACHED UNITS (SEE NOTES FOR ADDRESSES)
FPContractor:
RIOS FIRE PROTECTION-INACTIVE
P0 BOX 1546
EL CAJON, CA 92022-0000
(619) 212-0956
FEE AMOUNT
FIRE NFPA 13D Single Family System (Insp/Bldg) $125.00
FIRE NFPA 13D Single Family System (Plan Review) $246.00
Total Fees: $371.00 Total Payments To Date: $371.00 Balance Due: $0.00
Fire Department Page 1 of 1
1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov
- Fire Protection by Computer Design
Rios Fire Protection
P0 BOX 1546
EL CAJON, CA 92022
(619) 212-0956
Job Name : TAMARACK BEACH HOMES
Building
Location
System : UNIT I
Contract
Data File : UNIT 1 - TYPE Al - 2 HD 20x20 CALC.WXF
Computer Programs by Hydratec Inc. Revision: 50.52.1
Rios Fire Protection Page 1
- TAMARACK BEACH HOMES Date 8/26/19
HYDRAULIC CALCULATIONS
for
Project name: TAMARACK BEACH HOMES
Location:
Drawing no:
Date: 8/26/19
Design
Remote area number: UNIT 1
Remote area location: 3RD FLOOR
Occupancy classification: RES
Density: .05 - GpmlSqFt
Area of application: 2 HEADS - SqFt
Coverage per sprinkler: 400 - SqFt
Type of sprinklers calculated: TYCO 4.9K TY3596 CONCEALED PENDENTS
No. of sprinklers calculated: 2
In-rack demand: - GPM
Hose streams: 0 - GPM
Total water required (including hose streams): 40.3396 -GPM @ 73.0749 - Psi
Type of system: WET
Volume of dry orpreaction system: -Gal
Water supply information
Date: 6/28/19
Location: TAMARACK SOUTH OF HIBISCUS
Source: CARLSBAD FIRE DEPARTMENT
Name of contractor: Rios Fire Protection
Address: P0 BOX 1546! / EL CAJON, CA 92022
Phone number: (619) 212-0956
Name of designer: J B
Authority having jurisdiction: CAR LSBAD FIRE
Notes: (Include peaking information or gridded systems here.)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Water Supply Curve C
Rios Fire Protection Page 2
TAMARACK BEACH HOMES Date 8/26/19
City Water Supply: Demand:
Cl - Static Pressure : 75.6 Dl - Elevation : 12.919
C2 - Residual Pressure: 66.6 D2 - System Flow : 40.34
C2 - Residual Flow : 1500 D2 - System Pressure : 73.075
Hose ( Demand)
D3 - System Demand : 40.34
Safety Margin : 2.514
150
140
130
p120
R11°
E100
90
U 70
80 132
C2
-
_____
_____ _______
______ _________
_________ ___________
__________
_____________ _____
R6°
E5°
40
30
20
10 -9-1—
..I
200 400 600 800 1000 1200 1400 1600 1800
FLOW ( N ' 1.85)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Fittings Used Summary
Rios Fire Protection Page 3
TAMARACK BEACH HOMES Date 8/26/19
Fitting Legend
Abbrev. Name % % 1 1% 1% 2 2% 3 3% 4 5 6 8 10 12 14 16 18 20 24
35 40 45 50 61
7 8 10 11 13
0 0 0 0 0
0 0 0 0 0
0 0 0 0 0
71 81 91 101 121
E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27
G NFPA 13Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6
N * CPVC 90Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0
0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0
R* CPVC Coupling Tee - Run I I I 1 1 1 2 2 0 0 0 0 0 0 0
S NFPA 13Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65
T NFPAI39O Flow thruTee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60
Zik Wilkins 950XL Fitting generates a Fixed Loss Based on Flow
Unit Summary
Diameter Units Inches
Length Units Feet
Flow Units US Gallons per Minute
Pressure Units Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with * The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Revision: 50.52.1
- Pressure / Flow Summary - STANDARD
Rios Fire Protection Page 4
Date 8/26/19
Node
No.
Elevation K-Fact Pt
Actual
Pn Flow Density
Actual
Area Press
Req.
11 29.83 4.9 16.7 na 20.02 0.05 400 16.7
12 29.83 4.9 17.19 na 20.32 0.05 400 16.7
Al 29.83 17.62 na
A2 29.83 24.31 na
A3 19.66 32.49 na
A4 19.66 37.18 na
A5 9.5 45.86 na
A6 0.0 60.03 na
TR1 9.5 59.38 na
BR1 1.0 64.61 na
Ui -2.0 66.16 na
U2 -2.0 66.55 na
U3 -2.0 66.55 na
U4 -2.0 66.55 na
UG1 -2.0 66.55 na
UG2 -2.0 66.55 na
UG3 -2.0 66.55 na
UG4 -2.0 67.11 na
UG5 -2.0 73.94 na
SRC 0.0 73.07 na
The maximum velocity is 13.59 and it occurs in the pipe between nodes Al and A2
Computer Programs by Hydratec Inc. Revision: 50.52.1
- Final Calculations - Hazen-Williams - 2007
Page 5
Date 8/26/19
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftngs Fe Pv Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
11 20.02 1.101 0 5.0 8.420 16.700 K Factor =4.90
to 150.0 0.0 5.000 0.0
Al 20.02 0.0682 0.0 13.420 0.915 Vel = 6.75
0.0
20.02 17.615 KFactor= 4.77
12 20.32 1.101 0 5.0 1.080 17.189 K Factor 4.90
to 150.0 0.0 5.000 0.0
Al 20.32 0.0701 0.0 6.080 0.426 Vel = 6.85
0.0
20.32 17.615 K Factor = 4.84
**
Al 40.34 1.101 20 10.0 15.870 17.615
to 150.0 R 1.0 11.000 0.0
A2 40.34 0.2492 0.0 26.870 6.695 Vet = 13.59
A2 0.0 1.101 0 5.0 10.160 24.310
to 150.0 0.0 5.000 4.405
A3 40.34 0.2491 0.0 15.160 3.777 Vet = 13.59
A3 0.0 1.101 20 10.0 7.830 32.492
to 150.0 R 1.0 11.000 0.0
A4 40.34 0.2491 0.0 18.830 4.691 Vel = 13.59
A4 0.0 1.101 N 7.0 10.160 37.183
to 150.0 0.0 7.000 4.400
AS 40.34 0.2492 0.0 17.160 4.276 VeI= 13.59
A5 0.0 1.101 N 7.0 23.370 45.859
to 150.0 0 5.0 17.000 4.114
A6 40.34 0.2492 SR 5.0 40.370 10.059 Vet = 13.59
A6 0.0 1.394 2N 16.0 26.910 60.032
to 150.0 R 1.0 17.000 -4.114
TRI 40.34 0.0790 0.0 43.910 3.467 Vet = 8.48
TR1 0.0 1.394 S 11.11 8.500 59.385
to . 150.0 0.0 11.110 3.681
BRI 40.34 0.0789 0.0 19.610 1.548 Vet = 8.48
BRI 0.0 1.985 2E 12.407 5.000 64.614
to 150.0 0.0 12.407 1.299
UI 40.34 0.0142 0.0 17.407 0.247 Vet = 4.18
0.0
40.34 66.160 K Factor = 4.96
**
UI 40.34 2.047 T 14.412 17.660 66.160
to 150.0 0.0 14.412 0.0
UG3 40.34 0.0121 0.0 32.072 0.389 Vet = 3.93
0.0
40.34 66.549 K Factor = 4.94
U2 0.0 2.047 E 7.206 41.080 66.549
to 150.0 0.0 7.206 0.0
UG1 0.0 0.0 0.0 48.286 0.0 Vet = 0
0.0
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams
Rios Fire Protection Page 6
TAMARACK BEACH HOMES Date 8/26/19
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. 11C..or Ftngs Pe Pv ***** Notes ******
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
0.0 66.549 K Factor = 0
U3 0.0 2.047 T 14.412 7.330 66.549
to 150.0 0.0 14.412 0.0
UGI 0.0 0.0 0.0 21.742 0.0 Vet = 0
0.0
0.0 66.549 K Factor = 0
U4 0.0 2.047 T 14.412 7.330 66.549
to 150.0 0.0 14.412 0.0
UG2 0.0 0.0 0.0 21.742 0.0 Vel=0
0.0
0.0 66.549 K Factor= 0
**
UGI 0.0 2.047 0.0 32.000 66.549
to 150.0 0.0 0.0 0.0
UG2 0.0 0.0 0.0 32.000 0.0 Vet = 0
UG2 0.0 2.047 0.0 21.830 66.549
to 150.0 0.0 0.0 0.0
UG3 0.0 0.0 0.0 21.830 0.0 Vel = 0
UG3 40.34 2.047 2E 14.412 32.000 66.549
to 150.0 0.0 14.412 0.0
UG4 40.34 0.0122 0.0 46.412 0.565 Vet = 3.93
UG4 0.0 1.985 4E 24.814 8.000 67.114
to 150.0 Zik 0.0 24.814 6.359 * Fixed Loss = 6.359
UG5 40.34 0.0141 0.0 32.814 0.463 Vet = 4.18
UG5 0.0 6.16 G 4.304 28.330 73.936
to 140.0 T 43.037 47.341 -0.866
SRC 40.34 0.0001 0.0 75.671 0.005 Vet = 0.43
0.0
40.34 73.075 K Factor= 4.72
Computer Programs by Hydratec Inc. Revision: 50.52.1
Fire. Protection by Computer Design
Rios Fire Protection
PD BOX 1546
EL CAJON, CA 92022
(619) 212-0956
Job Name : TAMARACK BEACH HOMES
Building
Location
System : UNIT 2
Contract
Data File : UNIT 2-3 - TYPE A -2 HD 20x20 CALC.WXF
Computer Programs by Hydratec Inc. Revision: 50.52.1
Rios Fire Protection Page 1
TAMARACK BEACH HOMES Date 8/26/19
HYDRAULIC CALCULATIONS
for
Project name: TAMARACK BEACH HOMES
Location:
Drawing no:
Date: 8/26/19
Design
Remote area number: UNIT 2
Remote area location: 3RD FLOOR
Occupancy classification: RES
Density: .05 - Gpm/SqFt
Area of application: 2 HEADS - SqFt
Coverage per sprinkler: 400 - SqFt
Type of sprinklers calculated: TYCO 4.9K TY3596 CONCEALED PENDENTS
No. of sprinklers calculated: 2
In-rack demand: - GPM
Hose streams: 0 - GPM
Total water required (including hose streams): 41.37-GPM @ 70.51 -Psi
Type of system: WET
Volume of dry orpreaction system: -Gal
Water supply information
Date: 6/28/19
Location: TAMARACK SOUTH OF HIBISCUS
Source: CARLSBAD FIRE DEPARTMENT
Name of contractor: Rios Fire Protection
Address: P0 BOX 1546/ / EL CAJON, CA 92022
Phone number: (619) 212-0956
Name of designer: J
Authority having jurisdiction: CARLSBAD FIRE
Notes: (Include peaking information or gridded systems here.)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Water Supply Curve C
Rios Fire Protection Page 2
TAMARACK BEACH HOMES Date 8/26/19
City Water Supply: Demand:
Cl - Static Pressure : 75.6 Dl - Elevation 12.919
C2 - Residual Pressure: 66.6 02 - System Flow : 41.372
C2 - Residual Flow : 1500 D2 - System Pressure : 70.510
Hose ( Demand
D3 - System Demand : 41.372
Safety Margin : 5.078
150
140
130
p120
R0
E10°
S90
80
-
GI-
-D2-- C2 u 70 - -
R 60
E5°
40
30
20
10 --B-I-
.
200 400 600 800 1000 1200 1400 1600 1800
FLOW ( N A 1.85)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Fittings Used Summary
Rios Fire Protection Page 3
TAMARACK BEACH HOMES Date 8/26/19
Fitting Legend
Abbrev. Name 1/2 % 1 1% 1% 2 2Y2 3 3% 4 5 6 8 10 12 14 16 18 20 24
E NFPA 1390 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61
G NFPA13Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13
N * CPVC 90Ell Harvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0
0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0
R* CPVCCouplinglee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0
S NFPA13Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65
T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121
Zik Wilkins 950XL Fitting generates a Fixed Loss Based on Flow
Unit Summary
Diameter Units Inches
Length Units Feet
Flow Units US Gallons per Minute
Pressure Units Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with * The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Revision: 50.52.1
Pressure I Flow Summary - STANDARD
Rios Fire Protection Page 4
Date 8/26/19
Node
No.
Elevation K-Fact Pt
Actual
Pn Flow Density
Actual
Area Press
Req.
21 29.83 4.9 16.7 na 20.02 0.05 400 16.7
22 29.83 4.9 18.98 na 21.35 0.05 400 16.7
Bi 29.83 17.62 na
B2 29.83 19.45 na
93 19.66 27.81 na
94 19.66 32.73 na
B5 9.5 41.61 na
B6 0.0 56.26 na
TR2 9.5 55.78 na
BR2 1.0 61.08 na
Ui -2.0 63.94 na
U2 -2.0 62.64 na
U3 -2.0 63.26 na
U4 -2.0 63.66 na
UG1 -2.0 63.26 na
UG2 -2.0 63.66 na
UG3 -2.0 63.94 na
UG4 -2.0 64.53 na
UG5 -2.0 71.37 na
SRC 0.0 70.51 na
The maximum velocity is 13.94 and it occurs in the pipe between nodes B2 and B3
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams - 2007
Rios Fire Protection Page 5
TAMARACK BEACH HOMES Date 8/26/19
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C..or Ftng's Pe Pv ******* Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
21 20.02 1.101 0 5.0 8.420 16.700 K Factor 4.90
to 150.0 0.0 5.000 0.0
BI 20.02 0.0682 0.0 13.420 0.915 Vel = 6.75
0.0
20.02 17.615 KFactor= 4.77
22 21.35 1.101 0 5.0 1.080 18.981 K Factor =4.90
to 150.0 0.0 5.000 0.0
B2 21.35 0.0768 0.0 6.080 0.467 Vel = 7.19
0.0
21.35 19.448 K Factor = 4.84
**
BI 20.02 1.101 20 10.0 15.870 17.615
to 150.0 R 1.0 11.000 0.0
B2 20.02 0.0682 0.0 26.870 1.833 Vel = 6.75
B2 21.35 1.101 0 5.0 10.160 19.448
to 150.0 0.0 5.000 4.405
B3 41.37 0.2610 0.0 15.160 3.957 Vel = 13.94
B3 0.0 1.101 20 10.0 7.830 27.810
to 150.0 R 1.0 11.000 0.0
B4 41.37 0.2611 0.0 18.830 4.916 Vel= 13.94
B4 0.0 1.101 N 7.0 10.160 32.726
to 150.0 0.0 7.000 4.400
B5 41.37 0.2611 0.0 17.160 4.481 Vel = 13.94
B5 0.0 1.101 N 7.0 23.370 41.607
to 150.0 0 5.0 17.000 4.114
B6 41.37 0.2611 5R 5.0 40.370 10.540 Vel= 13.94
B6 0.0 1.394 2N 16.0 26.910 56.261
to 150.0 R 1.0 17.000 -4.114
TR2 41.37 0.0827 0.0 43.910 3.633 Vel = 8.70
TR2 0.0 1.394 S 11.11 8.500 55.780
to 150.0 0.0 11.110 3.681
BR2 41.37 0.0827 0.0 19.610 1.622 Vel= 8.70
BR2 0.0 1.985 2E 12.407 5.000 61.083
to 150.0 0.0 12.407 1.299
U2 41.37 0.0148 0.0 17.407 0.258 Vel = 4.29
0.0
41.37 62.640 KFactor= 5.23
**
UI 0.0 2.047 T 14.412 17.660 63.941
to 150.0 0.0 14.412 0.0
UG3 0.0 0.0 0.0 32.072 0.0 Vel = 0
0.0
0.0 63.941 K Factor = 0
U2 41.37 2.047 E 7.206 41.080 62.640
to 150.0 0.0 7.206 0.0
UGI 41.37 0.0127 0.0 48.286 0.615 Vel = 4.03
0.0
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams
Rios Fire Protection Page 6
TAMARACK BEACH HOMES Date 8/26/19
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftng's Pe Pv *** Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
41.37 63.255 K Factor = 5.20
U3 0.0 2.047 T 14.412 7.330 63.255
to 150.0 0.0 14.412 0.0
UG1 0.0 0.0 0.0 21.742 0.0 Vel =0
0.0
0.0 63.255 K Factor = 0
U4 0.0 2.047 T 14.412 7.330 63.663
to 150.0 0.0 14.412 0.0
UG2 0.0 0.0 0.0 21.742 0.0 Vel = 0
0.0
0.0 63.663 K Factor = 0
**
UG1 41.37 2.047 0.0 32.000 63.255
to 150.0 0.0 0.0 0.0
UG2 41.37 0.0127 0.0 32.000 0.408 Vel = 4.03
UG2 0.0 2.047 0.0 21.830 63.663
to 150.0 0.0 0.0 0.0
UG3 41.37 0.0127 0.0 21.830 0.278 Vel = 4.03
UG3 0.0 2.047 2E 14.412 32.000 63.941
to 150.0 0.0 14.412 0.0
UG4 41.37 0.0127 0.0 46.412 0.591 Vel = 4.03
UG4 0.0 1.985 4E 24.814 8.000 64.532
to 150.0 Zik 0.0 24.814 6.353 * Fixed Loss = 6.353
UGS 41.37 0.0148 0.0 32.814 0.486 Vel = 4.29
UGS 0.0 6.16 G 4.304 28.330 71.371
to 140.0 T 43.037 47.341 -0.866
SRC 41.37 0.0001 0.0 75.671 0.005 Vel = 0.45
0.0
41.37 70.510 KFactor= 4.93
Computer Programs by Hydratec Inc. Revision: 50.52.1
- Fire Protection by Computer -Design
Rios Fire Protection
P0 Box 1546
EL CAJON, CA 92022
(619) 212-0956
Job Name : TAMARACK BEACH HOMES
Building
Location
System : UNIT 4
Contract
Data File : UNIT 4- TYPE B -2 HD 20x20 CALC.WXF
Computer Programs by Hydratec Inc. Revision: 50.52.1
Rios Fire Protection Page 1
TAMARACK BEACH HOMES Date 8/26/19
HYDRAULIC CALCULATIONS
for
Project name: TAMARACK BEACH HOMES
Location:
Drawing no:
Date: 8/26/19
Design
Remote area number: UNIT 4
Remote area location: 2ND FLOOR
Occupancy classification: RES
Density: .05 - Gpm/SqFt
Area of application: 2 HEADS - SqFt
Coverage per sprinkler: 400 - SqFt
Type of sprinklers calculated: TYCO 4.9K TY3596 CONCEALED PENDENTS
No. of sprinklers calculated: 2
In-rack demand: - GPM
Hose streams: 0- GPM
Total water required (including hose streams): 40.09-GPM @ 56.15 - Psi
Type of system: WET
Volume of dry or preaction system: -Gal
Water supply information
Date: 6/28/19
Location: TAMARACK SOUTH OF HIBISCUS
Source: - CARLSBAD FIRE DEPARTMENT
Name of contractor: Rios Fire Protection
Address: PG BOX 1546/ / EL CAJON, CA 92022
Phone number: (619) 212-0956
Name of designer: J B
Authority having jurisdiction: CARLSBAD FIRE
Notes: (Include peaking information or gridded systems here.)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Water Supply Curve C
Rios Fire Protection Page 2
TAMARACK BEACH HOMES Date 8/26/19
City Water Supply: Demand:
Cl - Static Pressure : 75.6 Dl - Elevation : 8.515
C2 - Residual Pressure: 66.6 D2 - System Flow : 40.094
C2- Residual Flow : 1500 D2 - System Pressure : 56.154
Hose ( Demand)
D3 - System Demand : 40.094
Safety Margin : 19.435
150 -
140
130
p120
R°
E100
s 90
s 80
C2 U 70
R 60
- -
-
02
E50
40
30 --
20 --
10
200 400 600 800 1000 1200 1400 1600 1800
FLOW ( N A 1.85)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Fittings Used Summary
Rios Fire Protection Page 3
TAMARACK BEACH HOMES Date 8/26/19
Fitting Legend
Abbrev. Name /2 % 1 1% 1% 2 2% 3 31/2 45 6 8 10 12 14 16 18 20 24
E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61
G NFPA 13Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13
0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0
R* CPVCCouplinglee - Run 1 1 1 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0
S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65
T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121
Zik Wilkins 950XL Fitting generates a Fixed Loss Based on Flow
Unit Summary
Diameter Units Inches
Length Units Feet
Flow Units US Gallons per Minute
Pressure Units Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with * The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Revision: 50.52.1
Pressure / Flow Summary - STANDARD
Rios Fire Protection Page 4
TAMARACK BEACH HOMES Date 8/26/19
Node
No.
Elevation K-Fact Pt
Actual
Pn Flow Density
Actual
Area Press
Req.
31 19.66 4.9 16.7 na 20.02 0.05 400 16.7
32 19.66 4.9 . 16.78 na 20.07 0.05 400 16.7
Cl 19.66 17.5 na
C2 19.66 24.1 na
C3 9.5 31.01 na
TR3 9.5 39.06 na
BR3 1.0 47.19 na
Ui -2.0 49.64 na
U2 -2.0 48.99 na
U3 -2.0 48.73 na
U4 -2.0 49.38 na
UGi -2.0 48.99 na
UG2 -2.0 49.38 na
UG3 -2.0 49.64 na
UG4 -2.0 50.2 na
UG5 -2.0 57.02 na
SRC 0.0 56.15 na
The maximum velocity is 13.51 and it occurs in the pipe between nodes Ci and C2
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams - 2007
- Rios Fire Protection Page 5
TAMARACK BEACH HOMES Date 8/26/19
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. "C" or Ftngs Pe Pv ***** Notes
Point Qt PfIFt Eqv. Ln. Total Pf Pn
31 20.02 1.101 0 5.0 6.790 16.700 K Factor =4.90
to 150.0 0.0 5.000 0.0
Cl 20.02 0.0682 0.0 11.790 0.804 Vet = 6.75
0.0
20.02 17.504 K Factor = 4.79
32 20.07 1.101 0 5.0 5.620 16.777 K Factor = 4.90
to 150.0 0.0 5.000 0.0
Cl 20.07 0.0685 0.0 10.620 0.727 Vel = 6.76
0.0
20.07 17.504 K Factor = 4.80
**
Cl 40.09 1.101 20 10.0 15.790 17.504
to 150.0 R 1.0 11.000 0.0
C2 40.09 0.2464 0.0 26.790 6.600 Vel = 13.51
C2 0.0 1.101 0.0 10.160 24.104
to 150.0 0.0 0.0 4.400
C3 40.09 0.2464 0.0 10.160 2.503 Vel = 13.51
C3 0.0 1.101 0.0 32.680 31.007
to 150.0 0.0 0.0 0.0
TR3 40.09 0.2464 0.0 32.680 8.051 Vet = 13.51
TR3 0.0 1.101 S 9.563 8.500 39.058
to 150.0 0.0 9.562 3.681
BR3 40.09 0.2464 0.0 18.062 4.450 Vet = 13.51
BR3 0.0 1.985 2E 12.407 5.000 47.189
to 150.0 0.0 12.407 1.299
U3 40.09 0.0140 0.0 17.407 0.244 Vet = 4.16
0.0
40.09 48.732 K Factor = 5.74
**
UI 0.0 2.047 1 14.412 17.660 49.640
to 150.0 0.0 14.412 0.0
UG3 0.0 0.0 0.0 32.072 0.0 Vet = 0
0.0
0.0 49.640 K Factor = 0
U2 0.0 2.047 E 7.206 41.080 48.993
to 150.0 0.0 7.206 0.0
UG1 0.0 0.0 0.0 48.286 0.0 Vet = 0
0.0
0.0 48.993 K Factor = 0
U3 40.09 2.047 T 14.412 7.330 48.732
to 150.0 0.0 14.412 0.0
UG1 40.09 0.0120 0.0 21.742 0.261 Vet = 3.91
0.0
40.09 - 48.993 K Factor = 5.73
U4 0.0 2.047 - T 14.412 7.330 49.378
to 150.0 0.0 14.412 0.0
UG2 0.0 0.0 0.0 21.742 0.0 Vet = 0
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams
- Rios Fire Protection Page 6
TAMARACK BEACH HOMES Date 8/26/19
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref."C',or Ftngs Pe Pv ******* Notes
Point Qt P1/Ft Eqv. Ln. Total Pf Pn
0.0
0.0 49.378 K Factor = 0
**
UG1 40.09 2.047 0.0 32.000 48.993
to 150.0 0.0 0.0 0.0
UG2 40.09 0.0120 0.0 32.000 0.385 Vet = 3.91
UG2 0.0 2.047 0.0 21.830 49.378
to 150.0 0.0 0.0 0.0
UG3 40.09 0.0120 0.0 21.830 0.262 Vel = 3.91
UG3 0.0 2.047 2E 14.412 32.000 49.640
to 150.0 0.0 14.412 0.0
UG4 40.09 0.0120 0.0 46.412 0.558 Vet = 3.91
UG4 0.0 1.985 4E 24.814 8.000 50.198
to 150.0 Zik 0.0 24.814 6.359 * Fixed Loss = 6.359
UG5 40.09 0.0140 0.0 32.814 0.458 Vet = 4.16
UG5 0.0 6.16 G 4.304 28.330 57.015
to 140.0 T 43.037 47.341 -0.866
SRC 40.09 0.0001 0.0 75.671 0.005 Vel = 0.43
0.0
40.09 56.154 KFactor= 5.35
Computer Programs by Hydratec Inc. Revision: 50.52.1
F-W-. t _wq
- Fire Protection by Computer-Design
Rios Fire Protection
P0 BOX 1546
EL CAJON, CA 92022
(619) 212-0956
Job Name : TAMARACK BEACH HOMES
Building
Location
System : UNIT 5
Contract
Data File : UNIT 5 - TYPE Bi - 2 HD 20x20 CALC.WXF
Computer Programs by Hydratec Inc. Revision: 50.52.1
- Rios Fire Protection Page 1
TAMARACK BEACH HOMES Date 8/26/19
HYDRAULIC CALCULATIONS
for
Project name: TAMARACK BEACH HOMES
Location:
Drawing no:
Date: 8/26/19
Design
Remote area number: UNIT 5
Remote area location: 2ND FLOOR
Occupancy classification: RES
Density: .05 - Gpm/SqFt
Area of application: 2 HEADS - SqFt
Coverage per sprinkler: 400 - SqFt
Type of sprinklers calculated: TYCO 4.9K TY3596 CONCEALED PENDENTS
No. of sprinklers calculated: 2
In-rack demand: - GPM
Hose streams: 0- GPM
Total water required (including hose streams): 40.08-GPM @ 56.49- Psi
Type of system: WET
Volume of dry orpreaction system: -Gal
Water supply information
Date: 6/28/19
Location: TAMARACK SOUTH OF HIBISCUS
Source: CARLSBAD FIRE DEPARTMENT
Name of contractor: Rios Fire Protection
Address: P0 BOX 1546 / I EL CAJON, CA 92022
Phone number: (619) 212-0956
Name of designer: J
Authority having jurisdiction: CARLSBAD FIRE
Notes: (Include peaking information or gridded systems here.)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Water Supply Curve C
Rios Fire Protection Page 2
TAMARACK BEACH HOMES Date 8/26/19
City Water Supply: Demand:
Cl - Static Pressure : 75.6 Dl - Elevation : 8.515
C2 - Residual Pressure: 66.6 D2 - System Flow : 40.084
C2 - Residual Flow : 1500 D2 - System Pressure : 56.493
Hose ( Demand)
D3 - System Demand : 40.084
Safety Margin : 19.096
150
140
130
p120
R11°
E10°
s 9°
80
U 70 -____
R 60
E5°
40
30
20
10
200 400 600 800 1000 1200 1400 1600 1800
FLOW ( N"1.85)
Computer Programs by Hydratec Inc. Revision: 50.52.1
Fittings Used Summary
Rios Fire Protection Page 3
TAMARACK BEACH HOMES Date 8/26/19
Filling Legend
Abbrev. Name 1/2 % 1 1/4 11/2 2 2% 3 31/2 4 5 6 8 10 12 14 16 18 20 24
E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61
G NFPA 13Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13
N* CPVC9OEllHarvel-Spears 7 7 8 9 11 12 13 0 0 0 0 0 0 0 0 0 0 0 0
0* CPVCTee - Branch 3 3 5 6 8 10 12 15 0 0 0 0 0 0 0 0 0 0 0 0
R* CPVC Coupling Tee - Run I I I 1 1 1 2 2 0 0 0 0 0 0 0 0 0 0 0 0
S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65
T NFPA 13 90 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121
Zik Wilkins 950XL Filling generates a Fixed Loss Based on Flow
Unit Summary
Diameter Units Inches
Length Units Feet
Flow Units US Gallons per Minute
Pressure Units Pounds per Square Inch
Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters.
Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors
of 120 except as noted with *• The fittings marked with a * show equivalent lengths values
supplied by manufacturers based on specific pipe diameters and CFactors and they require no
adjustment. All values for fittings not marked with a * will be adjusted in the calculation
for CFactors of other than 120 and diameters other than Sched 40 per NFPA.
Computer Programs by Hydratec Inc. Revision: 50.52.1
Pressure / Flow Summary - STANDARD
Rios Fire Protection Page 4
Date 8/26119
Node
No.
Elevation K-Fact Pt
Actual
Pn Flow Density
Actual
Area Press
Req.
41 19.66 4.9 16.76 na 20.06 0.05 400 16.7
42 19.66 4.9 16.7 na 20.02 0.05 400 16.7
Di 19.66 17.5 na
D2 19.66 24.35 na
D3 9.5 31.25 na
TR4 9.5 39.78 na
BR4 1.0 47.91 na
Ui -2.0 49.98 na
U2 -2.0 49.72 na
U3 -2.0 49.72 na
U4 -2.0 49.46 na
UGI -2.0 49.72 na
UG2 -2.0 49.72 na
UG3 -2.0 49.98 na
UG4 -2.0 50.54 na
UG5 -2.0 57.35 na
SRC 0.0 56.49 na
The maximum velocity is 13.51 and it occurs in the pipe between nodes Dl and D2
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams - 2007
Page 5
Date 8126119
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. .1c..or Ftngs Pe Pv Notes
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
41 20.06 1.101 0 5.0 5.750 16.760 K Factor =4.90
to 150.0 0.0 5.000 0.0
Dl 20.06 0.0684 0.0 10.750 0.735 Vet = 6.76
0.0
20.06 17.495 K Factor = 4.80
42 20.02 1.101 0 5.0 6.660 16.700 K Factor =4.90
to 150.0 0.0 5.000 0.0
Dl 20.02 0.0682 0.0 11.660 0.795 Vel = 6.75
0.0
20.02 17.495 K Factor = 4.79
**
Dl 40.08 1.101 20 10.0 16.830 17.495
to 150.0 R 1.0 11.000 0.0
D2 40.08 0.2462 0.0 27.830 6.853 Vel = 13.51
D2 0.0 1.101 0.0 10.160 24.348
to 150.0 0.0 0.0 4.400
D3 40.08 0.2463 0.0 10.160 2.502 Vet = 13.51
D3 0.0 1.101 20 10.0 17.660 31.250
to 150.0 N 7.0 17.000 0.0
TR4 40.08 0.2462 0.0 34.660 8.535 Vet = 13.51
TR4 0.0 1.101 S 9.563 8.500 39.785
to 150.0 0.0 9.562 3.681
BR4 40.08 0.2463 0.0 18.062 4.448 Vet = 13.51
BR4 0.0 1.985 2E 12.407 5.000 47.914
to 150.0 0.0 12.407 1.299
U4 40.08 0.0140 0.0 17.407 0.243 Vet = 4.16
0.0
40.08 49.456 K Factor = 5.70
**
UI 0.0 2.047 T 14.412 17.660 49.980
to 150.0 0.0 14.412 0.0
UG3 0.0 0.0 0.0 32.072 0.0 Vet = 0
0.0
0.0 49.980 K Factor = 0
U2 0.0 2.047 E 7.206 41.080 49.717
to 150.0 0.0 7.206 0.0
UGI 0.0 0.0 0.0 48.286 0.0 Vel = 0
0.0
0.0 49.717 K Factor =0
U3 0.0 2.047 T 14.412 7.330 49.717
to 150.0 0.0 14.412 0.0
UGI 0.0 0.0 0.0 21.742 0.0 Vel =0
0.0
0.0 49.717 K Factor =0
U4 40.08 2.047 T 14.412 7.330 49.456
to 150.0 0.0 14.412 0.0
UG2 40.08 0.0120 0.0 21.742 0.261 Vet = 3.91
Computer Programs by Hydratec Inc. Revision: 50.52.1
Final Calculations - Hazen-Williams
Rios Fire Protection Page 6
TAMARACK BEACH HOMES Date 8/26/19
Hyd. Qa Dia. Fitting Pipe Pt Pt
Ref. ..C..or Ftng's Pe Pv *** Notes ******
Point Qt Pf/Ft Eqv. Ln. Total Pf Pn
0.0
40.08 49.717 K Factor = 5.68
**
UGI 0.0 2.047 0.0 32.000 49.717
to 150.0 0.0 0.0 0.0
UG2 0.0 0.0 0.0 32.000 0.0 Vel = 0
UG2 40.08 2.047 0.0 21.830 49.717
to 150.0 0.0 0.0 0.0
UG3 40.08 0.0120 0.0 21.830 0.263 Vel = 3.91
UG3 0.0 2.047 2E 14.412 32.000 49.980
to 150.0 0.0 14.412 0.0
UG4 40.08 0.0120 0.0 46.412 0.557 Vel = 3.91
UG4 0.0 1.985 4E 24.814 8.000 50.537
to 150.0 Zik 0.0 24.814 6.359 * Fixed Loss = 6.359
UG5 40.08 0.0140 0.0 32.814 0.458 Vet = 4.16
UG5 0.0 6.16 G 4.304 28.330 57.354
to 140.0 T 43.037 47.341 -0.866
SRC 40.08 0.0001 0.0 75.671 0.005 Vet = 0.43
0.0
40.08 56.493 K Factor= 5.33
Computer Programs by Hydratec Inc. Revision: 50.52.1
tqca Worldwide I www.tyco-fire.com Contacts
Series TY-FRB, 56 K-factor
Upright, Pendent, and Recessed Pendent Sprinklers
Quick Response, Standard Coverage
General
Description
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (TY313) and Pendent (1Y323)
Sprinklers described in this data sheet
are quick response, standard coverage,
decorative 3 mm glass bulb-type spray
sprinklers designed for use in light or
ordinary hazard, commercial occupan-
cies such as banks, hotels, and shop-
ping malls.
The recessed version of the Series
TY-FRB Pendent Sprinkler, where
applicable, is intended for use in areas
with a finished ceiling. This recessed
pendent sprinkler uses one of the
following:
A two-piece Style 15 Recessed
Escutcheon with recessed adjust-
ment up to 5/8 in. (15,9 mm) from
the flush pendent position.
A two-piece Style 20 Recessed
Escutcheon with recessed adjust-
ment up to 1/2 in. (12,7 mm) from
the flush pendent position.
The adjustment provided by the
Recessed Escutcheon reduces the
accuracy to which the fixed pipe drops
to the sprinklers must be cut.
Intermediate level versions of Series
TY-FRB Sprinklers are described in
Technical Data Sheet TFP357. Sprin-
kler guards and shields are described
in Technical Data Sheet TFP780.
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP 700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 4
LNOTICE
The TYCO Series TY-FRB Sprinklers
described herein must be installed
and maintained in compliance with
this document, as well as with the
applicable standards of the National
Fire Protection Association, in addition
to the standards of any other authori-
ties ha ving jurisdiction. Failure to do so
may impair the performance of these
devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Number (SIN)
TY313.... Upright 5.6K, 1/2 in. NPT
TY323 .... Pendent 5.6K, 1/2 in. NPT
Technical
Data
Approvals
Refer to Table A
Maximum Working Pressure
175 psi (12.1 bar)
250 psi (17.2 bar)*
The maximum working pressure of 250 psi (17.2 bar) only applies to the listing by Underwriters Laborato-ries, Inc. (UL).
Discharge Coefficient
K=5.6 GPM/p5i½ (80,6 LPM/bar½)
Temperature Rating
Refer to Table A
Finishes
Sprinkler: Refer to Table B
Recessed Escutcheon: White Coated,
Black Coated, Chrome Plated, or Brass
Plated
Physical Characteristics
Frame ............................Bronze
Button ......................Brass/copper
Sealing Assembly . . . Stainless Steel w/TEFLON
Bulb...............................Glass
Compression Screw .................Bronze
Deflector ..........................Bronze
AUGUST 2018
Operation
The glass bulb contains a fluid which
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and water to flow.
Design
Criteria
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (1Y313) and Pendent (TY323)
Sprinklers are intended for fire protec-
tion systems designed in accordance
with the standard installation rules
recognized by the applicable Listing or
Approval agency (such as, UL Listing
is based on the requirements of NFPA
13, and FM Approval is based on the
requirements of FM's Loss Prevention
Data Sheets). Only the Style 15 or Style
20 Recessed Escutcheon is to be used
for recessed pendent installations.
TFPI72
TFPI72
Page 2 of 4
Components:
1 - Frame
2 - Button
3 - Sealing
Assembly
* Temperature rating is Pipe thread connections per ISO 7-1 4 - Bulb indicated on Deflector. can be provided on special request. 5 - Compression
Screw ESCUTCHEON PLATE 1/2° 7/16° (11,1 mm)
6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE-IN
I 7/16 I (11,1 mm) I NOMINAL
MAKE-IN
iV 2
(50,8 mm) 1
1/2 NPT**
STYLE 15 or 20
RECESSED
ESCUTCHEON
2°
(50,8 I
WRENCH
FLATS
DEFLECTOR* I— 2-7/8" (73,0 mm) DIA.
CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT
FIGURE 1
SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS
5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE
Installation
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (1Y313) and Pendent (TY323)
Sprinklers must be installed in accor-
dance with this section.
General Instructions
Do not install any bulb-type sprin-
kler if the bulb is cracked or there is
a loss of liquid from the bulb. With the
sprinkler held horizontally, a small air
bubble should be present. The diam-
eter of the air bubble is approximately
1/16 in. (1,6 mm)forthe 135°F(57°C)and
3/32 in. (2,4 mm) for the 286°F (141°C)
temperature ratings.
A leak-tight 1/2 in. NPT sprinkler joint
should be obtained by applying a
minimum to maximum torque of 7 to
14 lb-ft (9,5 to 19,0 N.m). Higher levels
of torque can distort the sprinkler Inlet
with consequent leakage or impairment
of the sprinkler.
Do not attempt to compensate for
insufficient adjustment in the Escutch-
eon Plate by under- or over-tightening
the sprinkler. Re-adjust the position of
the sprinkler fitting to suit.
Upright and Pendent Sprinklers
The Series TY-FRB Upright and
Pendent Sprinklers must be installed
in accordance with the following
instructions.
Step 1. Install Pendent sprinklers in the
pendent position. Install upright sprin-
klers in the upright position.
Step 2. With pipe-thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Figure 2). With ref-
erence to Figure 1, apply the W-Type 6
Sprinkler Wrench to the wrench flats.
Torque sprinklers 7 to 14 lb-ft (9,5 to
19,0 N•m).
Recessed Pendent Sprinklers
The Series TY-FRB Recessed Pendent
Sprinklers must be installed in accor-
dance with the following instructions.
Step A. After installing the Style 15
or Style 20 Mounting Plate over the
sprinkler threads, and with pipe-thread
sealant applied to the pipe threads,
hand-tighten the sprinkler into the
sprinkler fitting.
Step B. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
7 Recessed Sprinkler Wrench (Figure
3). With reference to Figure 1, apply the
W-Type 7 Recessed Sprinkler Wrench
to the sprinkler wrench flats. Torque
sprinklers 7 to 14 lb-ft (9,5 to 19,0 Nm).
Step C. After ceiling installation and
finishing, slide on the Style 15 or Style
20 Closure over the Series TY-FRB
Sprinkler and push the Closure over the
Mounting Plate until its flange comes in
contact with the ceiling.
/ WRENCH RECESS
/ (USE ONLY
ND
FIGURE 2
W-TYPE 6
SPRINKLER WRENCH
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 3
W-TYPE 7 RECESSED
SPRINKLER WRENCH
TFPI72
Page 3 of 4
Care and
Maintenance
The TYCO Series TY-FRB, 5.6 K-factor,
Upright (TY313) and Pendent (TY323)
Sprinklers must be maintained and ser-
viced in accordance with this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
that it controls, obtain permission to
shut down the affected fire protection
systems from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover
a clearance hole, can delay sprinkler
operation in a fire situation.
The owner must assure that the sprin-
klers are not used for hanging any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprin-
kler that has a cracked bulb or that has
lost liquid from its bulb. (Ref. Installa-
tion Section.)
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or product manufacturer
with any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and Part Number
(P/N).
Sprinkler Assemblies with NPT
Thread Connections
Specify: Series TY-FRB Upright or
Pendent (specify) Sprinkler, SIN
(specify), K=5.6, Quick Response,
(specify) temperature rating, (specify)
finish, P/N (specify, refer to Table A).
Recessed Escutcheon
Specify: Style 15 Recessed Escutch-
eon with (specify*) finish, P/N (specify*)
Specify: Style 20 Recessed Escutch-
eon with (specify*) finish, P/N (specify*)
* Refer to Technical Data Sheet TFP770
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
- 2-7/8° DIA. -
(73,0 mm)
2-1/4° DIA.
FACE OF (57,2 mm)
5/8° (15,9 mm)
SPRINKLER
FITTING
3/8±5/16°
(9,5±7,9 mm)
___ 3 __
I FLUSH
t I
SURFACE/
MOUNTING
_______
(3,2 mm)
CLOSURE SERIES MOUNTING 1-3/8 (34,9 mm)
TY-FRB PLATE 3/4' (19,1 mm)
FIGURE 4
SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323)
WITH TWO PIECE 5/8 INCH TOTAL ADJUSTMENT STYLE 15
RECESSED ESCUTCHEON
- 2-7/8° DIA. - (73,0 mm)
FACE OF
SPRINKLER 2-1/4° DIA. -
5/16±1/4°
FITTING (57,2 mm)
(7,9±6,4 mm) 1/2°(12,7mm)
FLUSH
MOUNTING
j1
SURFACE/2mm)
\
CLOSURE SERIES MOUNTING 1-3/8'_(34,9mm)
TY-FRB PLATE 7/8'(22,2 mm)
FIGURE 5
SERIES TY-FRB RECESSED PENDENT SPRINKLER ASSEMBLY (TY323)
WITH TWO PIECE 1/2 INCH TOTAL ADJUSTMENT STYLE 20
RECESSED ESCUTCHEON
TFPI72
Page 4 of 4
SPRINKLER FINISH (See Note 7)
K
FACTOR TYPE TEMPERATURE BULB LIQUID
COLOR
NATURAL
BRASS
I CHROME
PLATED IPOLYESTERC
135°F (57°C) Orange
UPRIGHT
(TY313) 155°F (68°C) Red
175°F (79°C) Yellow and 1, 2,3,4, 5, 6
5.6
1/2 in. NPT
PENDENT (TY323) 200°F (93°C) Green
286-F (141-C) Blue
______________
135°F (57°C) Orange
RECESSED
PENDENT
(TY323)
Figures 4a and 5b
1,2,3,4 155°F (68°C) Red
175°F (79°C) Yellow
200°F (93°C) Green
Notes:
Listed by Underwriters Laboratories. Inc., (UL) as Quick Response Sprinklers.
Listed by Underwriters Laboratories. Inc., for use in Canada (C-UL) as Quick Response Sprinklers.
Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers.
Approved by the City of New York under MEA 354-01-B.
VdS Approved (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-54-428-3377.)
Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/06) as Quick Response Sprinklers.
Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.
Installed with Style 15 (1/2 in. NPT) 5/8 in. Total Adjustment Recessed Escutcheon, as applicable.
Installed with Style 20 (1/2 in. NPT) 1/2 in. Total Adjustment Recessed Escutcheon, as applicable.
Frame and Deflector only. Listings and approvals apply to color (Special Order).
TABLE A
LABORATORY LISTINGS AND APPROVALS FOR
5.6 K-FACTOR SPRINKLERS
P/Na 77_—XX-- X - XXX
SIN SPRINKLER
I
TEMPERATURE
FINISH I I RATINGS
NATURAL BRASS
PURE WHITE (RAL9010)s
POLYESTER
SIGNAL WHITE (RAL9003)
POLYESTER
JET BLACK (RAL9005)
POLYESTER
9 CHROME PLATED
Notes:
a. Eastern Hemisphere sales only
135 135-F (57-C)
155 155-F (68-C)
175 175-F (79-C)
200 200°F (93°C)
286 286-F (141-C)
370 I 5.6K UPRIGHT (1/21n.NPT) I TY313
371 1 5.6K PENDENT (1/2 in.NPT) I TY323
Notes:
a. Use suffix 'I' for ISO 7-1 connection; for example,
77-370-4-175-I
TABLE B
SERIES TY-FRB UPRIGHT AND PENDENT SPRINKLERS
PART NUMBER SELECTION
1400 Pennbrook Parkway, Lansdale, PA 19446 [Telephone +1-215-362-0700
@2O18Johnson Controls. All nglotvaeuerved. All sponlfloatloons and othsr lnfn,anntinn shown were current as of document revision date and are subject to change wabnllt notice. Johnson /1
NancraL Flea PROTECTION ASSOCIATION and NFFA or. r.stt.r.d frodnororks of Nntennl Fir. Protnutien Atnociolien: Controls TEFLON inn ragioterod trnderna,1, at Dupont
tqcco Worldwide www.tyco-fire.com Contacts
RAPID RESPONSE Series LFII Residential
49 K-factor Pendent Sprinkler
Wet Pipe and Dry Pipe Systems
General
Description
TYCO RAPID RESPONSE Series
LFII Residential 4.9K Pendent and
Recessed Pendent Sprinklers (TY2234)
are decorative, fast response, frangi-
ble bulb sprinklers designed for use
in residential occupancies such as
homes, apartments, dormitories, and
hotels. When aesthetics and optimized
flow characteristics are the major con-
sideration, the Series LFII Residential
Sprinklers (TY2234) should be the first
choice.
The Series LFII Residential Sprinklers
are intended for use in the following
scenarios:
wet and dry pipe residential sprin-
kler systems for one- and two-fam-
ily dwellings and mobile homes per
NFPA 13D
wet and dry pipe residential sprinkler
systems for residential occupancies
up to and including four stories in
height per NFPA 13R
wet and dry pipe sprinkler systems
for the residential portions of any
occupancy per NFPA 13
The recessed version of the Series
LFII Residential Sprinklers is intended
for use in areas with finished ceilings.
It employs a two-piece Style 20
Recessed Escutcheon. The Recessed
Escutcheon provides 1/4 in. (6,4 mm)
of recessed adjustment or up to 1/2 in.
(12,7 mm) of total adjustment from the
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fall
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 6
flush ceiling position. The adjustment
provided by the Recessed Escutcheon
reduces the accuracy to which the pipe
drops to the sprinklers must be cut.
The Series LFII Residential Sprinklers
have been designed with heat sensi-
tivity and water distribution charac-
teristics proven to help in the control
of residential fires and to improve the
chance for occupants to escape or be
evacuated.
Corrosion-resistant coatings, where
applicable, are utilized to extend the life
of copper alloy sprinklers beyond that
which would otherwise be obtained
when exposed to corrosive atmo-
spheres. Although corrosion-resistant
coated sprinklers have passed the
standard corrosion tests of the appli-
cable Approval agencies, the testing is
not representative of all possible cor-
rosive atmospheres. Consequently,
it is recommended that the end user
be consulted with respect to the suit-
ability of these coatings for any given
corrosive environment. The effects of
ambient temperature, concentration of
chemicals, and gas/chemical velocity
should be considered, as a minimum,
along with the corrosive nature of the
chemical to which the sprinklers will be
exposed.
Dry Pipe System Application
The Series LFII Residential Pendent
and Recessed Pendent Sprinklers
offers a laboratory approved option
for designing dry pipe residential sprin-
kler systems, whereas, most residential
sprinklers are laboratory approved for
wet systems only.
Through extensive testing, it has been
determined that the number of design
sprinklers (hydraulic design area) for
the Series LFII Residential Pendent and
Recessed Pendent Sprinklers (TY2234)
need not be increased over the number
of design sprinklers (hydraulic design
area) as specified for wet pipe sprinkler
systems, as is accustomed for density/
area sprinkler systems designed per
NFPA 13.
DECEMBER 2018
-
.'• _____ ' _y)
--
Consequently, the Series LFII Resi-
dential Sprinklers offer the features
of non-water filled pipe in addition
to not having to increase the number
of design sprinklers (hydraulic
design area) for systems designed to
NFPA 13,13D, or 13R.
NL•IIL•I
The Series LFII Residential Pendent
and Recessed Pendent Sprinklers
(TY2234) described herein must be
Installed and maintained in compli-
ance with this document and the appli-
cable standards of the NATIONAL FIRE
PROTECTION ASSOCIATION (NFPA),
in addition to the standards of any
authorities having jurisdiction. Failure
to do so may impair the performance
of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Number (SIN)
TY2234
TFP400
TFP400
Page 2 of 6
7/16' (11,1 mm) 1/2 ESCUTCHEON
Components: NOMINAL NPT PLATE SEATING _ 27/8' DIA.________
MAKE-IN SURFACE (73,0 mm) 1 - Frame
2 - Button
3 - Sealing Assembly 1
4 - Bulb
5 - Compression 2 2-1/4° Screw
6 - Deflector*
ILATS
(57,2 mm)
ESCUTCHEON
1-5/8"STYLE20 (41,3mm) w RECESSED
indicated on
\5
Temperature
rating is
Deflector.
CROSS SECTION PENDENT RECESSED PENDENT
FIGURE 1
RAPID RESPONSE SERIES LFII RESIDENTIAL
4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234)
Technical
Data
Approvals
UL Listed (for use with wet pipe and dry
pipe systems)
C-UL Listed (for use only with wet pipe
systems)
Certified to all requirements of
NSF/ANSI 61
Note: Sprinklers with a polyester finish
are UL Listed as corrosion-resistant
sprinklers.
See the Design Criteria section for details
on these approvals.
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K=4.9 GPM/psiS (70,6 LPM/bar 4)
Temperature Rating
155°F (68°C) or 175°F (79°C)
Finishes
Natural Brass, Pure White Polyester
Coated, Signal White Polyester Coated, or
Chrome Plated
Physical Characteristics
Frame .............................Brass
Button ...........................Copper
Sealing Assembly.. Beryllium Nickel w/TEFLON
Bulb (3 mm) ........................ Glass
Compression Screw .................Bronze
Deflector ..........................Bronze
Operation
The glass bulb Contains a fluid that
expands when exposed to heat. When
the rated temperature is reached, the
fluid expands sufficiently to shatter the
glass bulb, allowing the sprinkler to
activate and flow water.
Design
Criteria
The TYCO RAPID RESPONSE Series
LFll Residential 4.9K Pendent and
Recessed Pendent Sprinklers are UL
and C-UL Listed for installation in
accordance with this section.
Residential Sprinkler
Design Guide
When conditions exist that are outside
the scope of the provided criteria, refer
to the Residential Sprinkler Design
Guide TFP490 for the manufactur-
er's recommendations that may be
acceptable to the local authority having
jurisdiction.
System Types
Per the UL Listing, wet pipe and dry
pipe systems may be utilized. Per the
C-UL Listing, only wet pipe systems
may be utilized.
Refer to Technical Data Sheet TFP485
for the use of residential sprinklers in
residential dry pipe systems.
Ceiling Types
Smooth flat horizontal, or beamed, or
sloped, in accordance with the 2013
Edition of NFPA 13D, 13R, or 13, as
applicable.
Hydraulic Design
(NFPA 130 and 13R)
For systems designed to NFPA 130
or NFPA 13R, the minimum required
sprinkler flow rates are given in
Tables A and B as a function of tem-
perature rating and the maximum
allowable coverage areas. The
sprinkler flow rate is the minimum
required discharge from each of the
total number of design sprinklers as
specified in NFPA 13D or NFPA 13R.
The number of design sprinklers speci-
fied in NFPA 13D and 13R for wet pipe
systems is to be applied when design-
ing dry pipe systems.
Hydraulic Design
(NFPA 13)
For systems designed to NFPA 13, the
number of design sprinklers is to be
the four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
is to be the greater of the following:
The flow rates given in Table A or
B as a function of temperature
rating and the maximum allowable
coverage area.
A minimum discharge of 0.1 gpm/ft2
over the design area comprised
of the four most hydraulically
demanding sprinklers for actual
coverage areas protected by the
four sprinklers.
The number of design sprinklers speci-
fied in NFPA 13 for wet pipe systems is
to be applied when designing dry pipe
systems.
Dry Pipe System Water Delivery
When using the Series LFll Residential
Sprinklers (TY2234) in dry pipe sprin-
kler systems, the time for water deliv-
ery must not exceed 15 seconds for the
most remote operating sprinkler.
Obstruction to
Water Distribution
Sprinklers are to be located in accor-
dance with the obstruction rules of
NFPA 13D, 13R, and 13 as applicable
for residential sprinklers as well as with
the obstruction criteria described within
the Technical Data Sheet TFP490.
Operational Sensitivity
Sprinklers are to be installed with a
deflector-to-ceiling distance of 1-1/4 in.
to 4 in.
TFP400
Page 5 of 6
Care and
Maintenance
TYCO RAPID RESPONSE Series
LFII Residential 4.9K Pendent and
Recessed Pendent Sprinklers must be
maintained and serviced in accordance
with this section:
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system that
it controls, permission to shut down the
affected fire protection system must be
obtained from the proper authorities
and notify all personnel who may be
affected by this action.
Absence of the outer piece of an
escutcheon, which is used to cover
a clearance hole, can delay sprinkler
operation in a fire situation.
The owner must assure that the sprin-
klers are not used for hanging any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
Sprinklers which are found to be
leaking or exhibiting visible signs of
corrosion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modified sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid
damage to the sprinklers before,
during, and after installation. Sprin-
klers damaged by dropping, striking,
wrench twist/slippage, or the like, must
be replaced. Also, replace any sprinkler
that has a cracked bulb or that has lost
liquid from its bulb. Seethe Installation
section.
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the NATIONAL FIRE PROTECTION
ASSOCIATION, for example, NFPA 25,
in addition to the standards of any
authorities having jurisdiction. Contact
the installing contractor or product
manufacturer with any questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualified Inspec-
tion Service in accordance with local
requirements and/or national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and part number
(P/N).
Sprinkler Assemblies
Specify: Series LFll 4.9K Residential
Pendent Sprinkler (TY2234), (specify
temperature rating), with (specify) finish,
P/N (specify):
155F (68'C)
Natural Brass.................51-201-1-155 Pure White (RAL 9010)
Polyester1.2 ..................51 -201-3-155
Signal White (RAL 9003)
Polyester' .................... 51-201-4-155 Chrome Plated................51-201-9-155
175F (79C)
Natural Brass .................51-201-1-175
Pure White (RAL 9010) Polyester1.2 ..................51-201-3-175 Signal White (RAL 9003)
Polyester' .................... 51-201-4-175
Chrome Plated................51-201-9-175
UL Listed as corrosion-resistant. Eastern Hemisphere sales only.
Recessed Escutcheon
Specify: Style 20 Recessed Escutch-
eon with (specify*) finish, P/N (specify)
* Refer to Technical Data Sheet TFP770,
Sprinkler Wrenches
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
Specify: W-Type 7 Sprinkler Wrench,
P/N 56-850-4-001
TFP400
Page 3 of 6
WET PIPE SYSTEM
Minimum Flow and Residual Pressure (2){3)
Maximum
Coverage Ordinary Temperature Rating Intermediate Temperature Rating Minimum Area (1) 155°F (68°C) 175°F (79°C) Deflector to Installation Spacing
Flow Pressure Flow Pressure ft x ft Ceiling Type ft (mx m) gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar)
12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings
1-1/4 in. to 4 in. 14x14 13 7.0 13 7.0
(4,3 x 4,3) (49,2) (0,48) (49,2) (0,48) Beamed
Ceilings per
Recessed
using Style 20
Escutcheon or 8 16 x 16 13 7.0 13 7.0
(4,9 x 4,9) (49,2) (0,48) (49,2) (0,48) NFPA 13D
or13R
non-recessed
per NFPA 13D,
(2,4)
18x 18 17 12.0 17 12.0 1-1/4 in. to 13R, or 13
(5,5x5,5) (64,3) (0,83) (64,3) (0,83) 1-3/4 in. below
bottom of
beam. 20x20 20 16.7 20 16.7
(6,1 x6,1) (75,7) (1,15) (75,7) (1,15)
Notes:
For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design
criteria are stated.
Requirement is based on minimum flow in gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic
Design under the Design criteria section.
For NFPA 13 residential applications, the greater of 0.1 gpm/ft2 over the design area or the flow in accordance with the criteria in this table must be used.
TABLE A
WET PIPE SYSTEM
SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234)
NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA
DRY PIPE SYSTEM
Maximum Minimum Flow and Residual Pressure (2)(3)
Coveraae Ordinary Temperature Rating Intermediate Temperature Rating
Area ( 155°F (68°C) 175°F (79°C) Minimum
ft x ft Deflector to Installation Spacing
(m x m) Flow Pressure Flow Pressure Ceiling Type ft gpm psi gpm psi (m) (I/mm) (bar) (I/mm) (bar)
12x12 13 7.0 13 7.0 Smooth (3,7 x 3,7) (49,2) (0,48) (49,2) (0,48) Ceilings
1-1/4 in. to 4 in. 14 x 14 14 8.2 14 8.2
(4,3 x 4,3) (53,0) (0,57) (53,0) (0,57) Beamed
Ceilings
Recessed
using Style 20
Escutcheon or 8 16 x 16 15 9.4 15 9.4
(4,9 x 4,9) (56,8) (0,65) (56,8) (0,65) per NFPA 13D
or13R
non-recessed
per NFPA 13D,
(2,4)
18 x 18 18 13.5 18 13.5 1-1/4 in. to 13R, or 13 (5,5 x 5,5) (68,1) (0,93) (68,1) (0,93) 1-3/4 in. below
bottom of
beam. 20x20 21 18.4 21 18.4
(6,1 x 6,1) (79,5) (1,27) (79,5) (1,27)
Notes:
For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage area for which hydraulic design
criteria are stated.
Requirement is based on minimum flow In gpm (1pm) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. See Hydraulic
Design under the Design criteria section.
For NFPA 13 residential applications, the greater of 0.1 gpmfftt over the design area or the flow in accordance with the criteria in this table must be used.
TABLE B
DRY PIPE SYSTEM
SERIES LFII RESIDENTIAL 4.9K PENDENT AND RECESSED PENDENT SPRINKLERS (TY2234)
NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA
TFP400
Page 4 of 6
Sprinkler Spacing
The minimum spacing between sprin-
klers is 8 ft (2,4 m). The maximum
spacing between sprinklers cannot
exceed the length of the coverage area
(Table A or B) being hydraulically calcu-
lated (for example, maximum 12 ft for a
12 ft x 12 ft coverage area, or 20 ft for
a 20 ft x 20 ft coverage area).
Installation
TYCO RAPID RESPONSE Series
LFII Residential 4.9K Pendent and
Recessed Pendent Sprinklers must
be installed in accordance with this
section.
General Instructions
Do not install any bulb type sprinkler
if the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 in.
(1,6 mm).
A leak-tight 1/2 in. NPT sprinkler joint
should be obtained by applying a min-
imum-to-maximum torque of 7 to 14
lb-ft (9,5 to 19,0 N.m). Higher levels of
torque can distort the sprinkler Inlet
with consequent leakage or impairment
of the sprinkler.
Do not attempt to compensate for
insufficient adjustment in an Escutch-
eon Plate by under- or over- tightening
the sprinkler. Re-adjust the position of
the sprinkler fitting to suit.
Pendent Sprinklers
The Series LFII Residential Pendent
Sprinklers must be installed in accor-
dance with the following instructions:
Step 1. Install pendent sprinklers in the
pendent position with the deflector par-
allel to the ceiling.
Step 2. With pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
Step 3. Tighten the sprinkler into the
sprinkler fitting using only the W-Type
6 Sprinkler Wrench (Figure 3). With ref-
erence to Figure 1, apply the W-Type 6
Sprinkler Wrench to the wrench flats.
Recessed Pendent Sprinklers
The Series LFII Residential Recessed
Pendent Sprinklers must be installed
in accordance with the following
instructions:
Step A. Install recessed pendent sprin-
klers in the pendent position with the
deflector parallel to the ceiling.
Step B. After installing the Style 20
Mounting Plate over the sprinkler
threads and with pipe thread sealant
applied to the pipe threads, hand-
tighten the sprinkler into the sprinkler
fitting.
2-7/8' DIA.
7/16±1/8° (73,0 mm) 1/2° (12,7 mm)
(11,1±3,2mm)
FACE OF
2-1/4° DIA.
(57,2 mm)
1/4° (6,4 mm)
SPRINKLER I MOUNTING
FITTING PLATE
MOUNTING / f
SURFACE/ (3,2 mm)
/ 1-3/8° (34,9 mm) 1 CLOSURE TY2234 1-1/8' (28,6 mm)
FIGURE 2
STYLE 20 RECESSED ESCUTCHEON FOR USE WITH THE
RAPID RESPONSE SERIES LFII RESIDENTIAL PENDENT SPRINKLER
WRENCH RECESS
(END 'A' USED
FOR TY2234)
FIGURE 3
W-TYPE 6
SPRINKLER WRENCH
Step C. Tighten the sprinkler into the
sprinkler fitting using only the W-Type 7
Recessed Sprinkler Wrench (Figure 4).
With reference to Figure 1, apply the
W-Type 7 Recessed Sprinkler Wrench
to the sprinkler wrench flats.
Step D. After the ceiling has been
installed or the finish coat has been
applied, slide on the Style 20 Closure
over the Series LFII Residential Sprin-
kler and push the Closure over the
Mounting Plate until its flange comes
in contact with the ceiling.
WRENCH
RECESS
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 4
W-TYPE 7 RECESSED
SPRINKLER WRENCH
TFP400
Page 6 of 6
1400 Pennbrook Parkway, Lansdale, PA 194461 Telephone +1-215-362-0700
02O19Johnaon Controls. All fights aawraad. All apaeillaetiona and ether information ahowa wore cement on atdacamont minion date and oro subject tOEltengewithoat notice. Johnson
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are regi,torodtade,narke at Nadanal Fire Pnotoctlan Aesacintan; Controls TEFLON, a regiaterad trademark at Dupont
tqcuo Worldwide
Contacts I www.tyco-fire.com
RAPID RESPONSE Series LFII Residential
49 K-factor Concealed Pendent Sprinkler
Flat Plate, Wet Pipe and Dry Pipe Systems
General
Description
The TYCO RAPID RESPONSE Series
LFll Residential 4.9K Concealed
Pendent Sprinklers (TY3596) are dec-
orative, fusible solder sprinklers, avail-
able in both ordinary 160°F (71°C) and
intermediate 212°F (100°C) tempera-
ture rated configurations. They are
designed for use in residential occu-
pancies such as homes, apartments,
dormitories, and hotels.
The cover plate assembly conceals
the sprinkler operating components
above the ceiling. The flat profile of the
cover plate provides the optimum aes-
thetically appealing sprinkler design.
In addition, the concealed design
of the Series LFll Residential Con-
cealed Pendent Sprinklers provides
1/2 in. (12,7 mm) vertical adjustment.
This adjustment provides a measure
of flexibility when cutting fixed sprin-
kler drops.
The Series LFll Residential Concealed
Pendent Sprinklers are intended for use
in the following scenarios:
Wet and dry pipe residential sprin-
kler systems for one and two fam-
ily dwellings and mobile homes per
NFPA 13D
Wet and dry pipe residential sprin-
kler systems for residential occupan-
cies up to and including four stories
in height per NFPA 13R
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP 700 for the "INSTALLER
WARNING" that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Page 1 of 6
Wet and dry pipe sprinkler systems
for the residential portions of any
occupancy per NFPA 13
The Series LFll Residential Concealed
Pendent Sprinklers have been designed
with heat sensitivity and water distri-
bution characteristics proven to help
in the control of residential fires and to
improve the chance for occupants to
escape or be evacuated.
The Series LFll Residential Con-
cealed Pendent Sprinklers (TY3596)
are shipped with a Disposable Protec-
tive Cap. The Protective Cap is tem-
porarily removed for installation, and
then it can be replaced to help protect
the sprinkler while the ceiling is being
installed or finished. The tip of the Pro-
tective Cap can also be used to mark
the center of the ceiling hole into the
plaster board, ceiling tiles, and so on,
by gently pushing the ceiling product
against the Protective Cap. When the
ceiling installation is complete the Pro-
tective Cap is removed and the Cover
Plate Assembly is installed.
Dry Pipe System Application
The 160°F (71°C) temperature rated
Series LFll Residential Concealed
Pendent Sprinklers offer a laboratory
approved option for designing dry pipe
residential sprinkler systems, whereas,
most residential sprinklers are labora-
tory approved for wet systems only.
Through extensive testing, it has
been determined that the number of
design sprinklers (hydraulic design
area) for the Series LFll Residential
Concealed Pendent Sprinklers need
not be increased over the number of
design sprinklers (hydraulic design
area) as specified for wet pipe sprinkler
systems, as is accustomed for density/
area sprinkler systems designed per
NFPA 13.
APRIL 2019
Consequently, the Series LFII Residen-
tial Concealed Pendent Sprinklers offer
the features of non-water filled pipe in
addition to not having to increase the
number of design sprinklers (hydraulic
design area) for systems designed to
NFPA 13,13D, or 13R.
IL't•11DI
The Series LF11 Residential Concealed
Pendent Sprinklers (TY3596) described
herein must be installed and main-
tained in compliance with this docu-
ment and with the applicable standards
of the NATIONAL FIRE PROTECTION
ASSOCIATION (NFPA), in addition to
the standards of any authorities having
jurisdiction. Failure to do so may impair
the performance of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Number (SIN)
1Y3596
TFP442
TFP442
Page 2 of 6
Technical
Data
Approvals
UL and C-UL Listed
NYC Approved under MEA 44-03-E-2NSF
Certified to all requirements of
NSF/ANSI 61
The TYCO RAPID RESPONSE Series LFII
Residential Concealed Pendent Sprinklers are Listed only when installed with LFII Con-
cealed Cover Plates having factory-applied
finishes.
Sprinklers and Cover Plates are separately
ordered. See the Ordering Procedure
section for more Information.
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K=4.9 GPM/psi" (70,6 LPM/bare)
Temperature Rating
Ordinary
160°F (71°C) Sprinkler!
139°F (59°C) Cover Plate
NOTE: Maximum Ambient Ceiling Temperature for the ordinary temperature configuration Is 100°F (38°C)
Intermediate*
212°F (100°C) Sprinkler!
165°F (74°C) Cover Plate
*For wet pipe systems only NOTE: Maximum Ambient Ceiling Temperature for the intermediate temperature configuration is 150°F (65°C)
Vertical Adjustment
1/2 in. (12,7 mm)
Finishes
See the Ordering Procedure section
Physical Characteristics
Body..............................Brass
Cap ..............................Bronze Saddle ........................... ..Brass
Sealing Assembly.. Beryllium Nickel w/TEFLON
Soldered Link Halves ................Nickel
Lever .............................Bronze
Compression Screw ..................Brass
Deflector ..................Copper or Brass
Guide Pin Housing ..................Bronze
Guide Pins .........Stainless Steel or Bronze
Support Cup .......................Steel
Cover Plate ......... ........ Copper/Brass°
Retainer .........................Copper
Cover Plate Ejection Spring .... Stainless Steel
Brass Cover Plate is offered for intermediate Tem-perature 165°F (74°C) only.
Operation
When exposed to heat from a fire, the
Cover Plate, which is normally soldered
to the Retainer at three points, falls
away to expose the sprinkler assembly.
At this point the Deflector supported by
the Arms drops down to its operated
position. The fusible link of the sprin-
kler assembly is comprised of two link
halves that are soldered together with
a thin layer of solder. When the rated
temperature is reached, the solder
melts and the two link-halves separate
allowing the sprinkler to activate and
flow water.
Design Criteria
The TYCO RAPID RESPONSE Series
LFII Residential Concealed Pendent
Sprinklers (TY3596) are UL and C-UL
Listed for installation in accordance
with this section.
Note: When conditions exist that are
outside the scope of the provided cri-
teria, refer to the Residential Sprinkler
Design Guide TFP490 for the manu-
facturer's recommendations that may
be acceptable to the authority having
jurisdiction.
System Types
Per the UL and C-UL Listing, the
160°F (71°C) and 212°F (100°C) LFII
Residential Concealed Pendent Sprin-
klers may be utilized in wet pipe
systems. Only the 160°F (71°C) LFII Res-
idential Concealed Pendent Sprinklers
may be utilized in dry pipe systems, per
the ULand C-UL Listing.
Refer to Technical Data Sheet TFP485
about the use of residential sprinklers
in residential dry pipe systems.
Ceiling Types
Smooth flat horizontal, beamed, or
sloped in accordance with NFPA 13D,
13R, or 13 as applicable.
Hydraulic Design
(NFPA 13D and 13R)
For systems designed to NFPA 13D or
NFPA 13R, the minimum required Sprin-
kler flow rates are given in Tables A and
B as a function of temperature rating
and the maximum allowable coverage
areas.
The sprinkler flow rate is the minimum
required discharge from each of the
total number of "design sprinklers" as
specified in NFPA 13D or NFPA 13R.
The number of "design sprinklers"
specified in NFPA 13D and 13R for wet
pipe systems is to be applied when
designing dry pipe systems.
BODY SEALING
(1/2° NPT) ASSEMBLY
SPRINKLER
WRENCHING
AREA oil
I'llml I
SUPPORT EW CUP WITH
I - COMPRESSION
ROLL FORMED
SCR
LEVER
THREADSj
GUIDE
PIN OLDER LINK
ELEMENT
GUIDE PIN
HOUSING
DEFLECTOR / (OPERATED
POSITION)
I I
I SPRINKLER I ASSEMBLY
THREAD INTO I RETAINER
SUPPORT WITH THREAD
CUP UNTIL DIMPLES
MOUNTING
SURFACE IS
1j
FLUSH WITH
CEILING EJECTION
SPRING
SOLDER COVER PTE COVER
TAB ASSEMBLY PLATE
FIGURE 1
RAPID RESPONSE SERIES LFII RESIDENTIAL
CONCEALED PENDENT SPRINKLER (TY3596)
TFP442
Page 3 of 6
WET PIPE SYSTEM
Minimum Flow and Residual Pressure2'3
Maximum
Coverage Maximum
Spacing Temp. Rating Minimum Area 160°F (71°C), 212°F (100°C)
ft x ft ft Deflector to Installation Spacing
Flow Pressure (mx m) Ceiling Type ft
GPM psi (m)
(LPM) (bar)
12x12 12 13 7.0
(3,7 X 3,7) (3,7) (49,2) (0,48) Smooth
Ceilings
14x14 14 13 7.0 7/8tol-ll8in.
(4,3x4,3) (4,3) (49,2) (0,48) Beamed
Ceilings per
NFPA 13D or 8 16 x 16 16 13 7.0
(4,9 x 4,9) (4,9) (49,2) (0148) or 13.
Installed in
Concealed
13R, (2,4)
18x18 18 17 12.0 beam
(5,5x5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 in.
below bottom
of beam 20x20 20 20 16.7
(6,1 x6,1) (6,1) (75,7) (1,15)
Notes:
For coverage area dimensions less than or between those indicated, use the minimum required flow for the next highest coverage
area for which hydraulic design criteria are stated.
Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated
using the nominal K-factor. See Hydraulic Design under the Design Criteria section.
For NFPA 13 residential applications, the greater of 0.1 GPM/ft° over the design area or the flow in accordance with the criteria in
this table must be used.
TABLE A
WET PIPE SYSTEM
SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT SPRINKLER (TY3596)
NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA
DRY PIPE SYSTEM
Minimum Flow and Residual Pressure 2.3
Maximum
Coverage Maximum Ordinary Temp. Rating
Area Spacing 160°F (71°C) Minimum
ft x ft ft Deflector to Installation Spacing
Flow Pressure (m x m) (m) Ceiling Type ft
GPM psi (m)
(LPM) (bar)
12x12 12 13 7.0
(3,7 X 3,7) (3,7) (49,2) (0,48) Smooth
Ceilings
14x14 14 14 8.2 7/8tol-1/8in,
(4,3 x 4,3) (4,3) (53,0) (0,57) Beamed
Ceilings per
NFPA 130 or Concealed 8
(2,4) 16 x 16 16 15 9.4
(4,9 x 4,9) (4,9) (56,8) (0165) 13R, or 13.
Installed in
18x18 18 18 13.5 beam
(5,5x5,5) (5,5) (68,1) (0,93) 7/8t0 1-1/8 in.
below bottom
of beam 20 x 20 20 21 18.4
(6,1 x6,1) (6,1) (79,5) (1,27)
Notes:
For coverage area dimensions less than or between those indicated use the minimum required flow for the next highest coverage
area for which hydraulic design criteria are stated.
Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated us-
ing the nominal K-factor. See Hydraulic Design under the Design Criteria section.
For NFPA 13 residential applications, the greater of 0.1 GPM/ft° over the design area or the flow in accordance with the criteria in
this table must be used.
TABLE B
DRY PIPE SYSTEM
RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT (TY3596)
NFPA 13D, 13R, AND 13 HYDRAULIC DESIGN CRITERIA
COVER PLATE
RETAINER
1/2" (12,7 mm)
THREADED
ADJUSTMENT
OPERATED
SPRINKLER
TEMPERATURE
RATING
PROFILE
DEPTH
AIR
GAP
ORDINARY 3/16"(4,8mm) 1/8'(3,2mm)
INTERMEDIATE 5/32" (4,0 mm) 3/32" (2,4 mm)
2-1/2° DIA.
(63,5 mm)
1/2°
NPT. -
\ FACE OF
"- SPRINKLER
7/ 8°±1/4° FITTING G
V4(47,6 mm MOUNTING
6,4mm) SURFACE
JKLER- I
AT CUP PROFILE AIR
MBLY DEPTH GAP
(SEE (SEE
TABLE) TABLE)
COVER- SPRII
RETAINER SUPPC
ASSEMBLY ASS[
3-3/16' DIA.
(81,0 mm)
SPRINKLER-
SUPPORT CUP
ASSEMBLY
is i
5/8' (15,9 mm)
1-1/8° (28,6 mm)
DISPOSABLE ' DEFLECTOR IN
TIP PROTECTIVE CAP OPERATED POSITION
1FP442
Page 4 of 6
FIGURE 2
RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER (TY3596)
INSTALLATION DIMENSIONS, PROTECTIVE CAP, AND ACTIVATED DEFLECTOR
Hydraulic Design
(NFPA 13)
For systems designed to NFPA 13, the
number of design sprinklers is to be
the four most hydraulically demanding
sprinklers. The minimum required dis-
charge from each of the four sprinklers
is to be the greater of the following:
The flow rates given in Tables A and
B as a function of temperature rating
and the maximum allowable cover-
age area
A minimum discharge of
0.1 GPM/ft2 over the design area
comprised of the four most hydrauli-
cally demanding sprinklers for actual
coverage areas protected by the four
sprinklers
The number of design sprinklers speci-
fied in NFPA 13 for wet pipe systems is
to be applied when designing dry pipe
systems.
Dry Pipe System Water Delivery
When using the Series LFll Residen-
tial Concealed Pendent Sprinklers in
dry pipe sprinkler systems, the time
for water delivery must not exceed 15
seconds for the most remote operat-
ing sprinkler.
Obstruction to
Water Distribution
Sprinklers are to be located in accor-
dance with the obstruction rules of
NFPA 13D, 13R, and 13 as applicable
for residential sprinklers as well as with
the obstruction criteria described within
the Technical Data Sheet TFP490.
Operational Sensitivity
The sprinklers are to be installed rela-
tive to the ceiling mounting surface as
shown in Figure 2.
Sprinkler Spacing
The minimum spacing between sprin-
klers is 8 ft (2,4 m). The maximum
spacing between sprinklers cannot
exceed the length of the coverage area
(see Table A or B) being hydraulically
calculated (for example, maximum 12 ft
for a 12 ft x 12 ft coverage area, or 20 ft
for a 20 ft x 20 ft coverage area).
The Series LFll must not be used
in applications where the air pres-
sure above the ceiling is greater than
that below. Down drafts through the
Support Cup could delay sprinkler
operation in a fire situation.
Installation
The TYCO RAPID RESPONSE Series
LFll Residential Concealed Pendent
Sprinklers (TY3596) must be installed
in accordance with this section.
General Instructions
Damage to the fusible Link Assembly
during installation can be avoided by
handling the sprinkler by the support
cup only. Therefore, do not apply pres-
sure to the fusible Link Assembly.
A 1/2 in. NPT sprinkler joint should be
obtained with a minimum to maximum
torque of 7 to 14 lb-ft (9,5 to 19,0 N-m).
Higher levels of torque may distort the
sprinkler inlet with consequent leakage
or impairment of the sprinkler.
Do not attempt to compensate for
insufficient adjustment in the Cover
Plate Assembly by under-or over-
tightening the Sprinkler. Readjust the
position of the sprinkler fitting to suit.
Step 1. The sprinkler must only be
installed in the pendent position and
with the centerline of the sprinkler per-
pendicular to the mounting surface.
WRENCH
RECESS
i
PUSH WRENCH
IN TO ENSURE
ENGAGEMENT
WITH SPRINKLER
WRENCHING AREA
FIGURE 3
W-TYPE 18
SPRINKLER WRENCH
Step 2. Remove the Protective Cap.
Step 3. With pipe thread sealant
applied to the pipe threads, and
using the W-Type 18 Wrench shown
in Figure 3, install and tighten the
Sprinkler! Support Cup Assembly into
the fitting. The W-Type 18 Wrench will
accept a 1/2 in, ratchet drive.
Step 4. Replace the Protective Cap by
pushing it upwards until it bottoms out
against the Support Cup. The Protec-
tive Cap helps prevent damage to the
Deflector and Guide Pins during ceiling
installation and/or during application of
the finish coating of the ceiling. It may
also be used to locate the center of the
clearance hole by gently pushing the
ceiling material against the center point
of the Cap.
Note: As long as the protective Cap
remains in place, the system is consid-
ered to be "Out Of Service."
Step 5. After the ceiling has been com-
pleted with the 2-1/2 in. (63 mm) diam-
eter clearance hole and in preparation
TFP442
Page 5 of 6
for installing the Cover Plate Assembly,
remove and discard the Protective Cap,
and verify that the Deflector moves up
and down freely.
If the sprinkler has been damaged and
the Deflector does not move up and
down freely, replace the entire sprinkler
assembly. Do not attempt to modify or
repair a damaged sprinkler.
Step 6. Push on the
Assembly until its flan
contact with the ceiling.
Do not continue to push on the Cover
Plate Assembly such that it lifts a
ceiling panel out of its normal position.
If the Cover Plate Assembly cannot
be engaged with the Mounting Cup
or the Cover Plate Assembly cannot
be engaged sufficiently to contact the
ceiling, the Sprinkler Fitting must be
repositioned.
Care and
Maintenance
The TYCO RAPID RESPONSE
Series LFII Residential Concealed
Pendent Sprinklers (1Y3596) must be
maintained and serviced in accordance
with this section.
Before closing a fire protection system
main control valve for maintenance
work on the fire protection system
which it controls, permission to shut
down the affected fire protection
system must be obtained from the
proper authorities and all personnel
who may be affected by this action
must be notified.
Absence of a Cover Plate may delay the
sprinkler operation in a fire situation.
When properly installed, there is an air
gap between the lip of the Cover Plate
and the ceiling. The Ordinary Tem-
perature Cover Plate assembly has a
nominal 1/8 in. (3,2 mm) air gap. The
Intermediate Temperature Cover Plate
has a nominal 3/32 (2,4 mm) air gap,
as shown in Figure 2. This air gap is
necessary for proper operation of the
sprinkler by allowing heat flow from a
fire to pass below and above the Cover
Plate to help assure appropriate release
of the Cover Plate in a fire situation. If
the ceiling is to be repainted after the
installation of the Sprinkler, care must
be exercised to ensure that the new
paint does not seal off any of the air
gap.
Factory painted Cover Plates must not
be repainted. They should be replaced,
if necessary, by factory painted
units. Non-factory applied paint may
adversely delay or prevent sprinkler
operation in the event of a fire.
Do not pull the Cover Plate relative to
the Enclosure. Separation may result.
Sprinklers which are found to be
r exhibiting visible signs of
must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or otherwise
altered after leaving the factory. Modi-
fied or over heated sprinklers must be
replaced.
Care must be exercised to avoid
damage before, during, and after instal-
lation. Sprinklers damaged by drop-
ping, striking, wrench twist/slippage,
or the like, must be replaced.
The owner is responsible for the
inspection, testing, and maintenance of
their fire protection system and devices
in compliance with this document, as
well as with the applicable standards
of the NATIONAL FIRE PROTECTION
ASSOCIATION, for example, NFPA 25,
in addition to the standards of any other
authorities having jurisdiction. Contact
the installing contractor or product
manufacturer with any questions.
The owner must assure that the sprin-
klers are not used for hanging any
objects and that the sprinklers are only
cleaned by means of gently dusting
with a feather duster; otherwise, non-
operation in the event of a fire or inad-
vertent operation may result.
Automatic sprinkler systems should be
inspected, tested, and maintained by a
qualified Inspection Service in accor-
dance with local requirements and/or
national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-fire.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product name and part number
(PIN).
Sprinkler Assemblies
Specify: Series LFIl (TY3596) 4.9K Res-
idential Concealed Pendent Sprinkler,
P/N (specify):
160F (7lC)...................51-112-1-160
212F(100C) .................. 51-112-1-212
Note: Sprinkler and Cover Plates are
separately sold. See below for Cover
Plate ordering information.
Cover Plate Assemblies
Specify: LFll Concealed Sprinkler
Cover Plate Assembly, temperature
rating (specify), (specify) finish, P/N
(specify):
139'F (59-C) Ivory (RAL1015) ...............56-204-0-135 Bright Chrome ................ 56-204-1 -135
Beige (RAL1001) ..............56-204-2-135 Pure White (RAL9O1O). ......... 56-204-3-135
Signal White (RAL9003).. ....... 56-204-4-135
Grey White (RAL9002)..........56-204-5-135
Brown (RAL8028)..............56-204-6-135
Black (RAL9005) ..............56-204-7-135 Brushed Brass................56-204-8-135
Brushed Chrome ..............56-204-9-135
Custom Paint .................56-204-X-135
165'F (74-C) Ivory (RAL1015) ...............56-204-0-165
Bright Chrome ................56-204-1 165 Beige (RAL1001) ..............56-204-2-165 Pure White (RAL9O1O). ......... 56-204-3-165
Signal White (RAL9003).. ....... 56-204-4-165
Grey White (RAL9002)..........56-204-5-165 Brown (RAL8028)..............56-204-6-165
Black (RAL9005) ..............56-204-7-165
Brushed Brass ................56-204-8-165
Brushed Chrome ..............56-204-9-165
Custom Paint ................. 56-204-X-165
Eastern Hemisphere sales only **Previously known as Bright White
Note: All Custom Cover Plates are
painted using SHERWIN-WILLIAMS
Interior Latex Paint. Contact Johnson
Controls Customer Service with any
questions related to custom orders.
Sprinkler Wrench
Specify: W-Type 18 Sprinkler Wrench,
P/N 56-000-1-265
Cover Plate leaking c
ie comes in corrosion
TFP442
4 Page 6of6
1400 Pennbrook Parkway, Lansdale, PA 19446 I Telephone +1-215-362-0700 ,iJJ a'r
@zOtgJohnson Controls. All rights resumed. All spoolllootim.s and other information shown were current as of d000ment revision date and are subject toohongewltheot notion. Johnson
NATION*LFIREPRO1EC100uSSOOAflOhandhFpA0009iaeredfradernnrksofhatovalFirrp'otoctiooAssociuootr Controls TEFLON ieoregrnterrd trademark at Dupont SHERWTN4VIWAMS in a rellalered trademark of SWIMOLIS
WILKINS
Application
Designed for installation on water tines in fire protection sys-
tems to protect against both backsiphonage and backpressure
of polluted water into the potable water supply. A test cock plug
is provided to protect against fouling caused by insects, dirt
and debris. Assembly shall provide protection where a potential
non-health hazard exists.
Standards Compliance
UL® Classified (horizontal & vertical)
C-UL® Classified (horizontal & vertical)
ASSE listed 1048 (horizontal & vertical)
Approved by the Foundation for Cross Connection Control
and Hydraulic Research at the University of Southern
California (horizontal & vertical)
By-Pass Backflow Assembly 3/4U Model 350D
Materials
Main valve body Cast Bronze ASTM B 584
Access covers Cast Bronze ASTM B 584
Fasteners Stainless Steel, 300 Series
Elastomers Silicone (FDA approved)
Buna Nitrite (FDA approved)
Polymers NorylTM, NSF Listed
Springs Stainless steel, 300 series
Test cock cover Plastic
Options
(Suffixes can be combined)
O - with OS & Y gate valves (standard)
LM - less water meter
- with gal meter (standard)
CFM - with cu ft meter
Accessories
Repair kit (rubber only)
O OS & V Gate valve tamper switch (OSY-40)
QT-SET Quick Test Fitting Set
Features
Sizes: 2"
Maximum working water pressure 175 PSI
Maximum working water temperature 180°F
Hydrostatic test pressure 350 PSI
End connections (Threaded) ANSI B1.20.1
Dimensions & Weights (do not include pkg.)
MODEL
DIMENSIONS (approximate)
WEIGHT
SIZE A B C D E OS&V OPEN OS&Y CLOSED
in mm in mm in mm in mm in mm in mm in mm lbs kg
2 50 231/4 591 9 229 9 229 13 330 11 330 13/4 44 65 29.5
Zurn Industries, LLC I Wilkins
1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766
In Canada l Zurn Industries Limited
3544 Nashua Drive, Mississauga, Ontario L4V 11_2 Ph. 905-405-8272, Fax 905-405-1292
Rev. B
Date: 6/17
Document No. BF-950XLTDA
Product No. Model 950XLTDA
www.xurn.com I Page 1 of 2
a 20
Flow Characteristics
t
0.0 3.2
50
MODEL 950XLTDA 2' (STANDARD & METRIC)
FLOW RATE (Ifs)
6.3 9.5
100 150
FLOW RATE (GPM)
ORated Flow (established by approval agencies)
12.6 15.8
138
103
(I) 0 69
34
Lit of 0 0
250
Typical Installation
Local codes shall govern installation requirements. To be
installed in accordance with the manufacturer's instructions
and the latest edition of the Uniform Plumbing Code. Unless
otherwise specified, the assembly shall be mounted at a mini-
mum of 121 (305mm) and a maximum of 30" (762mm) above
adequate drains with sufficient side clearance for testing and
maintenance. The installation shall be made so that no part of
the unit can be submerged.
OUTDOOR INSTALLATION VERTICAL INSTALLATION
Specifications
The Double Check Detector Backflow Prevention Assembly shall be ASSE Listed 1048, and supplied with full port gate valves.
The main body and access covers shall be bronze (ASTM B 584), the seat ring and all internal polymers shall be NSF® Listed
Noryll and the seat disc elastomers shall be SILICONE. The first and second check shall be located at a 450 angle and ac-
cessible for maintenance from the top of the device, without removing the device from the line. Each check shall have sepa-
rate access covers and test cocks shall be accessible from the top of the device. Test cocks shall be protected from debris by
a plug. The Double Check Detector Backflow Prevention Assembly shall be a ZURN WILKINS Model 950XLTDA.
Zurn Industries, LLC I Wilkins
1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766
In Canada I Zurn Industries Limited
3544 Nashua Drive, Mississauga, Ontario L4V 112 Ph. 905-405-8272, Fax 905-405-1292
www.zurn.com Page 2 of 2