HomeMy WebLinkAbout2848 WHIPTAIL LP; ; FPC2017-0244; PermitPERII'flT REPORT taty of C? Print Date: 10/04/2022 Permit No: FPC2017-0244 Job Address: 2848 WHIPTAIL LOOP, CARLSBAD, CA 92010 Status: Closed - Finaled Permit Type: FIRE-Construction Commercial Work Class: Fire Sprinklers Parcel #: 2091201500 Track #: Applied: 08/23/2017 Valuation: $6,368,800.34 Lot #: Issued: 09/26/2017 Occupancy Group: Project #: Finaled Close Out: 09/02/2020 #of Dwelling Units: Plan #: Bedrooms: Construction Type: Final Inspection: Bathrooms: Orig. Plan Check 1*: INSPECTOR: Wong, Cindy Plan Check #: Fieri, Dominic Project Title: Description: HME WAREHOUSE -SPRINKLER TI >100 HEADS (738) Applicant: FPContractor: VANGUARD FIRE PROTECTION INC VANGUARD FIRE PROTECTION INC 417 CARLSBAD VILLAGE DR 417 CARLSBAD VILLAGE DR CARLSBAD, CA 92008-2302 CARLSBAD, CA 92008-2302 (760) 727-8540 (760) 727-8540 FEE AMOUNT FIRE NFPA 13 or 13R System> 100 heads $634.00 Total Fees: $634.00 Total Payments To Date: $634.00 Balance Due: $0.00 Fire Department Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 1 760-602-4665 1 760-602-8561 f I www.carlsbadca.gov CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: HME SR#: (Assigned upon plan submittal) PROJECT ADDRESS: APN 209-120-15 (Whiptail Loop) CITY: Carlsbad PHONE: ( 760) 727-8540 (Vanguard Fire Protection, Inc.) FAX NUMBER: (760) 727-8542 Largest Building (ft.2): Sprinkled? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Whiptail Loop E East of Gazelle Court TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 94 PSI Hydrant Number (if applicable):H61677 Elevation of test: 481 est. Feet Date/Time of Test': Pitot Tube Reading: PSI Corresponding Flow: - GPM Total Flow: 81000 GPM Residual Pressure 56 PSI At peak demand , this water system is capable of providing a fire flow discharge of 20 psi greater than 8,000 gpm. 1Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flow test (i.e. computer modeling), fill out the information above as applicable and check here: x Name: JenniferR.Mael,P.E. Eng. Lic. No. (if applicable): C69606 Signature: Title/Org P_iectManager Date: 11/14/2016 HME Fire Flow Analysis Prepared By: Jennifer R. Mael, P.E. - MCS Date: Monday, November 14, 2016 - Fire Protection by Computer Design VANGUARD FIRE PROTECTION P. 0. Box 1300 Vista, CA 92085 760-727-8540 Job Name : HME Whiptail Loop Building Location Whiptail Loop Carlsbad, CA System : Area #1 Contract : 8-12-17 Data File HME System 2 Area #1 Remote Area.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 VANGUARD FIRE PROTECTION Page 1 HME Whiptail Loop Date 8-12-17 HYDRAULIC CALCULATIONS for Project name: HME Whiptail Loop Location: Whiptail Loop Carlsbad, CA Drawing no: Date: 11-19-16 Design Remote area number: Area #1 Remote area location: PCA Dept. Occupancy classification: Ordinary Group II Density: .20 - Gpm/SqFt Area of application: 1500 - SqFt Coverage per sprinkler: 256 sq ft - SqFt Type of sprinklers calculated: 11.2K QR-Extended Coverage OH2 No. of sprinklers calculated: 8 In-rack demand: N/A - GPM Hose streams: 250 - GPM Total water required (including hose streams): 678.356 - GPM @ 71.138 - Psi Type of system: T I From Wet Grid Volume of dry or preaction system: N/A - Gal Water supply information Date: 11-14-2016 Location: Whiptail Loop E of Gazelle Court Source: Carlsbad Fire Department Name of contractor: Vanguard Fire Protection Address: P. 0. Box 1300 Vista, CA 92085 Phone number: 760-525-4329 Name of designer: VFP Authority having jurisdiction: Carlsbad Fire Departmen Notes: (Include peaking information or gridded systems here.) This calculation represents the most demanding pendent oriented remote area. Most of the improved spaces are Light Hazard except as noted. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 VVdLU OUl ,UIV %t.,) VANGUARD FIRE PROTECTION Page 2 HME Whiptail Loop - Date 8-12-17 City Water Supply: Demand: Cl -Static Pressure : 84.6 Dl - Elevation : 9.095 C2 - Residual Pressure: 50.4 02 - System Flow : 428.356 C2 - Residual Flow : 8000 02 - System Pressure : 71.138 Hose ( Demand) : 250 D3 - System Demand : 678.356 Safety Margin : 13.106 150 140 130 p120 R11° E100 s 90 S80 02 U70 R 60 - - - C2 EL DI 10002000 3000 4000 5000 6000 7000 8000 9000 FLOW (NA 1.85) Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 now LJIdIdIIl VANGUARD FIRE PROTECTION Page 3 HME Whiptail Loop Date 8-12-17 51 P1+-A I 33.2 511 P2 4-B t 17.8 51 P3 - C 544 P4 - 0 35.4 P5 +- E t I 18.9 54. P6 +-F 56.1 P7 - G 1.7 564 P8 +-H 7.4 50 +- 80 I t I 741 7.4 'I, 7.41 51 4-81 I 1- I 14.f 14.8 SI, •I 52 +-82 I t I 22.? 22.3 .1. 7.71 53 4-83 I 1' I 29.p 29.9 SI.7.91 54 4-84 I t I 37.9 37.9 SI, 8.31 55 +- 85 I t I 46. 46.2 .I, 8.91 56 . 86 I t I 55.1 55.1 Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 now UII dill VANGUARD FIRE PROTECTION HME Whiptail Loop 9.61 87 64.1 647 10.? +-88 T 75.1 75.1 11. - 89 86.y 86.7 12.? +-90 99.5 84.2 17.8 -A -B 4-C 4-91 33.2 68.8 15.3 I 168.3 89.8 18.9 -D -E 4-F 4-92 35.4 73.2 74.5 57.9 54.4 -G -H -93 1.7 132.4 14.2 4-94 1' 11.2 310.1 141 4- 95 T 101.3 324.1 14.? - 96 t 901 338.4 15. 4- 97 t 74.9 353.4 - 98 t 58.? 369.7 4- 99 1 40.9 387.4 19.? 4- 100 T 214 406.9 214 - 101 Page 4 Date 8-12-17 Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 ruuw LJIdIdIII VANGUARD FIRE PROTECTION Page 5 HME Whiptail Loop Date 8-12-17 -T 7.4 22.3 37.9 55.1 75.1 99.5 74.5 118.2 90 58.7 21.4 50 ._5f -*52 .-53 54 -+55 -),56 -+57 -+58 -+59 -+60 -~61 -+62 63 4-64 4-65 4-66 4-674-68 69 4-70 71 T f 14.9 t 29.9 t 46. t 64.1 t 86.1I 15.3 13214 f 1043 t 74.9 1' 40.9 t I 7•41 791 8.31 8.91 9.81 10.f 1 I.f 12.7 I 14. 141 14.p 15.1 16. 17.f 19.f 21.4 I 7.41 I 22.f I 37.9 I 55 1 I 75.1 I 99.5 241.5 I 31.1 I 33•4 I 369.7 I 409 428.4 428.4 428.4 306 306 80 81 82 83 84 85 86 - 87 +- 88 89 90 - 91 92 93 94 95 96 97 98 99 4- 1004- 1014- FM2- TR24- BRZ- MFfl- FLG- DI UGI4- UGX- BFI4- BF2 14.8 29.9 46.2 64.7 86.7 188.3 296 324.1 353.4 387.4 428.4 428.4 428.4 428.4 306 306 BF2<- CMI4- SRC 306 372.4 372.4 UGI+- BF34- BF44- CM24- SRC 372.4 372.4 Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 ruuiiiys utu ouiiiiiiiy VANGUARD FIRE PROTECTION HME Whiptail Loop Page Date 6 8-12-17 Fitting Legend - Abbrev. Name ½ Y4 1 11/4 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90 Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 1345Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390 Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. ComDuter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 Pressure I Flow Summary - STANDARD VANGUARD FIRE PROTECTION Page 7 HME Whiptail Loop Date 8-12-17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 51.03 1.0 1 20.74 51.01 1.0 1 20.74 51.01 1.0 1 20.74 54.35 1.0 1 20.74 54.32 1.0 1 20.74 54.33 1.0 1 20.74 56.15 1.0 1 20.74 56.15 1.0 1 20.74 12.0 11.2 20.76 na 12.0 11.2 20.74 na 12.0 11.2 20.75 na 25.5 11.2 23.55 na 25.5 11.2 23.52 na 25.5 11.2 23.53 na 25.5 11.2 25.13 na 25.5 11.2 25.13 na 31.58 50.61 na 31.58 50.61 na 31.58 50.61 na 31.58 50.61 na 31.58 50.61 na 31.58 50.6 na 31.58 50.6 na 31.58 50.59 na 31.58 50.58 na 31.58 50.56 na 31.58 50.55 na 31.58 50.52 na 32.58 48.78 na 32.58 48.73 na 32.58 48.74 na 31.58 50.52 na 32.58 48.61 na 32.58 48.55 na 32.58 48.57 na 31.58 50.54 na 32.58 49.3 na 32.58 49.3 na 31.58 50.58 na 31.58 50.62 na 31.58 50.65 na 31.58 50.67 na 31.58 50.68 na 31.58 50.69 na 31.58 50.7 na 31.58 50.7 na 31.58 50.66 na 31.58 50.66 na 31.58 50.66 na 31.58 50.66 na 31.58 50.66 na 31.58 50.66 na 31.58 50.66 na 31.58 50.66 na 31.58 50.66 na 31.58 50.67 na 31.58 50.67 na 31.58 50.67 na 31.58 50.68 na 31.58 50.7 na 31.58 50.73 na 31.58 50.76 na 31.58 50.8 na 31.58 50.83 na 31.58 50.88 na 31.58 50.92 na 31.58 50.97 na 31.58 51.02 na 31.58 51.14 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard VANGUARD FIRE PROTECTION Page 8 HME Whiptail Loop Date 8-12-17 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Rea. TR2 31.58 51.43 na BR2 2.0 64.92 na MFD 2.0 64.99 na FLG -4.0 67.63 na Dl -4.0 67.68 na UG1 -4.0 68.01 na UG2 -4.0 68.79 na BF1 -4.0 68.86 na BF2 -4.0 68.95 na CMI -9.0 71.13 na SRC -9.0 71.14 na BF3 -4.0 68.81 na BF4 -4.0 68.93 na CM2 -9.0 71.12 na The maximum velocity is 20.84 and it occurs in the pipe between nodes P7 and G 250.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 9 HME Whiptail Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. 11cf,or Ftng's Pe Pv ***** Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn P1 51.03 1.049 1E 2.0 43.170 20.760 K Factor = 11.20 to 120.0 IT 5.0 7.000 -8.913 A 51.03 0.7361 0.0 50.170 36.932 Vel = 18.94 0.0 51.03 48.779 K Factor = 7.31 P2 51.01 1.049 1 2.0 43.170 20.740 KFactor= 11.20 to 120.0 11 5.0 7.000 -8.913 B 51.01 0.7355 0.0 50.170 36.899 Vel = 18.94 0.0 51.01 48.726 K Factor = 7.31 P3 51.01 1.049 1E 2.0 43.170 20.746 KFactor 11.20 to 120.0 iT 5.0 7.000 -8.913 C 51.01 0.7357 0.0 50.170 36.910 Vet= 18.94 0.0 51.01 48.743 K Factor = 7.31 P4 54.35 1.049 1E 2.0 27.000 23.552 KFactor= 11.20 to 120.0 IT 5.0 7.000 -3.066 D 5435 0.8273 0.0 34.000 28.128 Vel = 20.18 0.0 54.35 48.614 KFactor= 7.80 P5 54.32 1.049 1E 2.0 27.000 23.524 K Factor= 11.20 to 120.0 iT 5.0 7.000 -3.066 E 54.32 0.8264 0.0 34.000 28.096 Vet = 20.17 0.0 54.32 48.554 K Factor = 7.80 P6 54.33 1.049 1E 2.0 27.000 23.533 K Factor= 11.20 to 120.0 iT 5.0 7.000 -3.066 F 54.33 0.8266 0.0 34.000 28.105 Vel = 20.17 0.0 54.33 48.572 K Factor = 7.80 P7 56.15 1.049 1 2.0 24.000 25.133 KFactor= 11.20 to 120.0 IT 5.0 7.000 -3.066 G 56.15 0.8785 0.0 31.000 27.235 VeI= 20.84 0.0 56.15 49.302 KFactor= 8.00 P8 56.15 1.049 1 2.0 24.000 25.133 K Factor = 11.20 to 120.0 1T 5.0 7.000 -3.066 H 56.15 0.8785 0.0 31.000 27.234 VeI= 20.84 0.0 56.15 49.301 K Factor = 8.00 50 7.39 2.703 4T 74.603 145.500 50.613 to 120.0 0.0 74.603 0.0 80 7.39 0.0002 0.0 220.103 0.046 Vel = 0.41 0.0 7.39 50.659 K Factor = 1.04 51 7.41 2.703 41 74.603 145.500 50.613 to 120.0 0.0 74.603 0.0 81 7.41 0.0002 0.0 220.103 0.046 Vet = 0.41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 10 HME Whiptail Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 7.41 50.659 K Factor = 1.04 52 7.49 2.703 4T 74.603 145.500 50.612 to 120.0 0.0 74.603 0.0 82 7.49 0.0002 0.0 220.103 0.047 Vel = 0.42 0.0 7.49 50.659 K Factor= 1.05 53 7.65 2.703 4T 74.603 145.500 50.611 to 120.0 0.0 74.603 0.0 83 7.65 0.0002 0.0 220.103 0.048 Vel = 0.43 0.0 7.65 50.659 K Factor = 1.07 54 7.93 2.703 4T 74.603 145.500 50.608 to 120.0 0.0 74.603 0.0 84 7.93 0.0002 0.0 220.103 0.051 Vel = 0.44 0.0 7.93 50.659 KFactor= 1.11 55 8.33 2.703 4T 74.603 145.500 50.604 to 120.0 0.0 74.603 0.0 85 8.33 0.0003 0.0 220.103 0.056 Vel = 0.47 0.0 8.33 50.660 K Factor = 1.17 56 8.90 2.703 41 74.603 145.500 50.597 to 120.0 0.0 74.603 0.0 86 8.9 0.0003 0.0 220.103 0.064 Vel = 0.50 0.0 8.90 50.661 K Factor= 1.25 57 9.56 2.703 41 74.603 145.500 50.590 to 120.0 0.0 74.603 0.0 87 9.56 0.0003 0.0 220.103 0.072 Vel = 0.53 0.0 9.56 50.662 K Factor = 1.34 58 10.47 2.703 4T 74.603 145.500 50.578 to 120.0 0.0 74.603 0.0 88 10.47 0.0004 0.0 220.103 0.086 Vel = 0.59 0.0 10.47 50.664 K Factor = 1.47 59 11.59 2.703 4T 74.603 145.500 50.562 to 120.0 0.0 74.603 0.0 89 11.59 0.0005 0.0 220.103 0.104 Vel = 0.65 0.0 11.59 50.666 K Factor = 1.63 60 12.73 2.703 4T 74.603 145.500 50.545 to 120.0 0.0 74.603 0.0 90 12.73 0.0006 0.0 220.103 0.124 Vel = 0.71 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 11 HME Whiptail Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. C" or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 12.73 50.669 K Factor = 1.79 61 -84.21 2.703 2T 37.301 33.500 50.523 to 120.0 0.0 37.301 -0.433 A -84.21 -0.0185 0.0 70.801 -1.311 VeI= 4.71 A 51.03 2.703 0.0 16.000 48.779 to 120.0 0.0 0.0 0.0 B -33.18 -0.0033 0.0 16.000 -0.053 Vel = 1.86 B 51.01 2.703 0.0 16.000 48.726 to 120.0 0.0 0.0 0.0 C 17.83 0.0011 0.0 16.000 0.017 Vel = 1.00 C 51.01 2.703 21 37.301 80.000 48.743 to 120.0 0.0 37.301 0.433 91 68.84 0.0128 0.0 117.301 1.496 Vel= 3.85 0.0 68.84 50.672 K Factor = 9.67 62 -89.78 2.703 2T 37.301 33.500 50.522 to 120.0 0.0 37.301 -0.433 D -89.78 -0.0208 0.0 70.801 -1.475 Vel = 5.02 D 54.35 2.703 0.0 16.000 48.614 to 120.0 0.0 0.0 0.0 E -35.43 -0.0038 0.0 16.000 -0.060 Vel = 1.98 E 54.33 2.703 0.0 16.000 48.554 to 120.0 0.0 0.0 0.0 F 18.9 0.0011 0.0 16.000 0.018 VeI= 1.06 F 54.33 2.703 2T 37.301 80.000 48.572 to 120.0 0.0 37.301 0.433 92 73.23 0.0143 0.0 117.301 1.677 Vel = 4.09 0.0 73.23 50.682 K Factor = 10.29 63 -57.88 2.703 21 37.301 49.500 50.538 to 120.0 0.0 37.301 -0.433 G -57.88 -0.0093 0.0 86.801 -0.803 Vel = 3.24 G 56.15 2.703 0.0 16.000 49.302 to 120.0 0.0 0.0 0.0 H -1.73 -0.0001 0.0 16.000 -0.001 Vel = 0.10 H 56.15 2.703 2T 37.301 80.000 49.301 to 120.0 0.0 37.301 0.433 93 54.42 0.0083 0.0 117.301 0.969 Vel= 3.04 0.0 54.42 50.703 K Factor = 7.64 64 14.16 2.703 41 74.603 145.500 50.582 to 120.0 0.0 74.603 0.0 94 14.16 0.0007 0.0 220.103 0.150 VeI= 0.79 0.0 14.16 50.732 K Factor = 1.99 65 13.97 2.703 4T 74.603 145.500 50.617 to 120.0 0.0 74.603 0.0 95 13.97 0.0007 0.0 220.103 0.147 VeI= 0.78 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 12 HME Whiptait Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. DC" or Ftng's Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 13.97 50.764 K Factor= 1.96 66 14.30 2.703 4T 74.603 145.500 50.646 to 120.0 0.0 74.603 0.0 96 14.3 0.0007 0.0 220.103 0.153 Vet = 0.80 0.0 14.30 50.799 KFactor= 2.01 67 15.06 2.703 4T 74.603 145.500 50.666 to 120.0 0.0 74.603 0.0 97 15.06 0.0008 0.0 220.103 0.169 Vet = 0.84 0.0 15.06 50.835 K Factor = 2.11 68 16.25 2.703 4T 74.603 145.500 50.682 to 120.0 0.0 74.603 0.0 98 16.25 0.0009 0.0 220.103 0.194 Vet = 0.91 0.0 16.25 50.876 K Factor = 2.28 69 17.75 2.703 4T 74.603 145.500 50.691 to 120.0 0.0 74.603 0.0 99 17.75 0.0010 0.0 220.103 0.229 Vel = 0.99 0.0 17.75 50.920 KFactor= 2.49 70 19.50 2.703 4T 74.603 145.500 50.696 to 120.0 0.0 74.603 0.0 100 19.5 0.0012 0.0 220.103 0.272 Vet = 1.09 0.0 19.50 50.968 K Factor = 2.73 71 21.42 2.703 4T 74.603 145.500 50.698 to 120.0 0.0 74.603 0.0 101 21.42 0.0015 0.0 220.103 0.324 Vet = 1.20 0.0 21.42 51.022 K Factor = 3.00 50 -7.39 4.31 0.0 8.500 50.613 to 120.0 0.0 0.0 0.0 51 -7.39 0.0 0.0 8.500 0.0 Vel = 0.16 51 -7.42 4.31 0.0 10.000 50.613 to 120.0 0.0 0.0 0.0 52 -14.81 -0.0001 0.0 10.000 -0.001 Vet = 0.33 52 -7.49 4.31 0.0 10.000 50.612 to 120.0 0.0 0.0 0.0 53 -22.3 -0.0001 0.0 10.000 -0.001 Vel = 0.49 53 -7.65 4.31 0.0 10.000 50.611 to 120.0 0.0 0.0 0.0 54 -29.95 -0.0003 0.0 10.000 -0.003 Vel = 0.66 54 -7.92 4.31 0.0 10.000 50.608 to 120.0 0.0 0.0 0.0 55 -37.87 -0.0004 0.0 10.000 -0.004 Vel = 0.83 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calcylations - Hazen-Williams VANGUARD FIRE PROTECTION Page 13 HME Whiptail Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 55 -8.34 4.31 0.0 10.000 50.604 to 120.0 0.0 0.0 0.0 56 46.21 -0.0007 0.0 10.000 -0.007 Vel = 1.02 56 -8.89 4.31 0.0 9.000 50.597 to 120.0 0.0 0.0 0.0 57 -55.1 -0.0008 0.0 9.000 -0.007 Vel = 1.21 57 -9.56 4.31 0.0 10.000 50.590 to 120.0 0.0 0.0 0.0 58 -64.66 -0.0012 0.0 10.000 -0.012 VeI= 1.42 58 -10.47 4.31 0.0 10.000 50.578 to 120.0 0.0 0.0 0.0 59 -75.13 -0.0016 0.0 10.000 -0.016 Vel = 1.65 59 -11.60 4.31 0.0 8.500 50.562 to 120.0 0.0 0.0 0.0 60 -86.73 -0.0020 0.0 8.500 -0.017 Vel = 1.91 60 -12.73 4.31 0.0 8.500 50.545 to 120.0 0.0 0.0 0.0 61 -99.46 -0.0026 0.0 8.500 -0.022 Vel = 2.19 61 8421 4.31 0.0 10.000 50.523 to 120.0 0.0 0.0 0.0 62 -15.25 -0.0001 0.0 10.000 -0.001 Vel = 0.34 62 89.78 4.31 0.0 10.000 50.522 to 120.0 0.0 0.0 0.0 63 74.53 0.0016 0.0 10.000 0.016 VeI= 1.64 63 57.87 4.31 0.0 10.000 50.538 to 120.0 0.0 0.0 0.0 64 132.4 0.0044 0.0 10.000 0.044 Vel = 2.91 64 -14.16 4.31 0.0 10.000 50.582 to 120.0 0.0 0.0 0.0 65 118.24 0.0035 0.0 10.000 0.035 Vel = 2.60 65 -13.97 4.31 0.0 10.000 50.617 to 120.0 0.0 0.0 0.0 66 104.27 0.0029 0.0 10.000 0.029 Vel = 2.29 66 -14.30 4.31 0.0 9.500 50.646 to 120.0 0.0 0.0 0.0 67 89.97 0.0021 0.0 9.500 0.020 Vel = 1.98 67 -15.06 4.31 0.0 10.000 50.666 to 120.0 0.0 0.0 0.0 68 74.91 0.0016 0.0 10.000 0.016 Vel = 1.65 68 -16.24 4.31 0.0 10.000 50.682 to 120.0 0.0 0.0 0.0 69 58.67 0.0009 0.0 10.000 0.009 Vel = 1.29 69 -17.75 4.31 0.0 10.000 50.691 to 120.0 0.0 0.0 0.0 70 40.92 0.0005 0.0 10.000 0.005 Vel = 0.90 70 -19.50 4.31 0.0 10.000 50.696 to 120.0 0.0 0.0 0.0 71 21.42 0.0002 0.0 10.000 0.002 Vel = 0.47 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calcylations - Hazen-Williams VANGUARD FIRE PROTECTION Page 14 HME Whiptail Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ***** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 21.42 50.698 K Factor = 3.01 80 7.39 6.357 0.0 8.500 50.659 to 120.0 0.0 0.0 0.0 81 7.39 0.0 0.0 8.500 0.0 Vet = 0.07 81 7.42 6.357 0.0 10.000 50.659 to 120.0 0.0 0.0 0.0 82 14.81 0.0 0.0 10.000 0.0 Vet= 0.15 82 7.49 6.357 0.0 10.000 50.659 to 120.0 0.0 0.0 0.0 83 22.3 0.0 0.0 10.000 0.0 Vel = 0.23 83 7.65 6.357 0.0 10.000 50.659 to 120.0 0.0 0.0 0.0 84 29.95 0.0 0.0 10.000 0.0 Vel = 0.30 84 7.92 6.357 0.0 10.000 50.659 to 120.0 0.0 0.0 0.0 85 37.87 0.0001 0.0 10.000 0.001 Vel = 0.38 85 8.34 6.357 0.0 10.000 50.660 to 120.0 0.0 0.0 0.0 86 46.21 0.0001 0.0 10.000 0.001 Vet = 0.47 86 8.89 6.357 0.0 9.000 50.661 to 120.0 0.0 0.0 0.0 87 55.1 0.0001 0.0 9.000 0.001 Vet = 0.56 87 9.56 6.357 0.0 10.000 50.662 to 120.0 0.0 0.0 0.0 88 64.66 0.0002 0.0 10.000 0.002 Vet = 0.65 88 10.47 6.357 0.0 10.000 50.664 to 120.0 0.0 0.0 0.0 89 75.13 0.0002 0.0 10.000 0.002 Vet = 0.76 89 11.60 6.357 0.0 8.500 50.666 to 120.0 0.0 0.0 0.0 90 86.73 0.0004 0.0 8.500 0.003 Vel = 0.88 90 12.73 6.357 0.0 8.500 50.669 to 120.0 0.0 0.0 0.0 91 99.46 0.0004 0.0 8.500 0.003 Vel = 1.01 91 68.84 6.357 0.0 10.000 50.672 to 120.0 0.0 0.0 0.0 92 168.3 0.0010 0.0 10.000 0.010 Vel = 1.70 92 73.23 6.357 0.0 10.000 50.682 to 120.0 0.0 0.0 0.0 93 241.53 0.0021 0.0 10.000 0.021 VeI= 2.44 93 54.42 6.357 0.0 10.000 50.703 to 120.0 0.0 0.0 0.0 94 295.95 0.0029 0.0 10.000 0.029 Vel = 2.99 94 14.16 6.357 0.0 10.000 50.732 to 120.0 0.0 0.0 0.0 95 310.11 0.0032 0.0 10.000 0.032 Vel = 3.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calcplations - Hazen-Williams VANGUARD FIRE PROTECTION Page 15 HME Whiptail Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C11 or Ftngs Pe Pv Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 95 13.97 6.357 0.0 10.000 50.764 to 120.0 0.0 0.0 0.0 96 324.08 0.0035 0.0 10.000 0.035 Vel = 3.28 96 14.30 6.357 0.0 9.500 50.799 to 120.0 0.0 0.0 0.0 97 338.38 0.0038 0.0 9.500 0.036 Vel = 3.42 97 15.06 6.357 0.0 10.000 50.835 to 120.0 0.0 0.0 0.0 98 353.44 0.0041 0.0 10.000 0.041 Vel = 3.57 98 16.25 6.357 0.0 10.000 50.876 to 120.0 0.0 0.0 0.0 99 369.69 0.0044 0.0 10.000 0.044 Vel = 3.74 99 17.75 6.357 0.0 10.000 50.920 to 120.0 0.0 0.0 0.0 100 387.44 0.0048 0.0 10.000 0.048 Vel = 3.92 100 19.50 6.357 0.0 10.000 50.968 to 120.0 0.0 0.0 0.0 101 406.94 0.0054 0.0 10.000 0.054 Vel = 4.11 101 21.42 6.357 IE 17.603 2.000 51.022 to 120.0 0.0 17.603 0.0 FM2 428.36 0.0058 0.0 19.603 0.114 Vel = 4.33 FM2 0.0 6.357 2E 35.205 14.920 51.136 to 120.0 0.0 35.205 0.0 TR2 428.36 0.0058 0.0 50.125 0.292 Vel = 4.33 TR2 0.0 6.357 1S 40.235 27.080 51.428 to 120.0 1 12.573 90.528 12.811 BR2 428.36 0.0058 iT 37.72 117.608 0.686 Vel = 4.33 BR2 0.0 8.249 iT 41.108 0.750 64.925 to 120.0 0.0 41.108 0.0 MFD 428.36 0.0016 0.0 41.858 0.068 Vel = 2.57 MFD 0.0 8.249 1E 21.141 3.670 64.993 to 120.0 0.0 21.141 2.599 FLG 428.36 0.0017 0.0 24.811 0.041 Vel= 2.57 FLG 0.0 8.27 1E 28.468 10.000 67.633 to 140.0 0.0 28.468 0.0 DI 428.36 0.0012 0.0 38.468 0.047 Vel = 2.56 DI 0.0 7.68 2E 45.11 118.000 67.680 to 150.0 IT 43.857 93.979 0.0 UG1 428.36 0.0015 1G 5.012 211.979 0.325 Vel= 2.97 UGI -122.38 7.68 5F 56.388 798.000 68.005 Qa = 250 to 150.0 IT 43.857 150.367 0.0 UG2 305.98 0.0008 2E 45.11 948.367 0.782 VeI= 2.12 1G 5.012 UG2 0.0 7.68 1 22.555 69.000 68.787 to 150.0 0.0 22.555 0.0 BF1 305.98 0.0008 0.0 91.555 0.076 Vel = 2.12 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 16 HME Whiptail Loop Date 8-12-17 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn BF1 0.0 8.27 iT 55.354 20.000 68.863 to 140.0 2E 56.936 112.290 0.0 BF2 305.98 0.0007 0.0 132.290 0.086 Vel = 1.83 BF2 0.0 11.2 1G 6.645 55.000 68.949 to 150.0 iT 66.446 73.090 2.166 CMI 305.98 0.0001 0.0 128.090 0.016 Vet = 1.00 CM1 0.0 15.94 IG 14.305 255.000 71.131 to 140.0 0.0 14.305 0.0 SRC 305.98 0.0 0.0 269.305 0.007 Vet = 0.49 0.0 305.98 71.138 KFactor= 36.28 UG1 372.38 7.68 5F 56.388 575.000 68.005 to 150.0 iT 43.857 100.245 0.0 BF3 372.38 0.0012 0.0 675.245 0.801 Vet = 2.58 BF3 0.0 8.27 iT 55.354 20.000 68.806 to 140.0 2E 56.936 112.290 0.0 BF4 372.38 0.0009 0.0 132.290 0.124 Vet = 2.22 BF4 0.0 11.2 iF 14.397 62.000 68.930 to 150.0 IG 6.645 87.487 2.166 CM2 372.38 0.0002 IT 66.446 149.487 0.028 Vet = 1.21 CM2 0.0 15.94 3G 42.916 340.000 71.124 to 140.0 0.0 42.916 0.0 SRC 372.38 0.0 0.0 382.916 0.014 Vet = 0.60 0.0 372.38 71.138 KFactor= 44.15 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 9 W... il. ~w I - - - Fire Protection by Computer Design VANGUARD FIRE PROTECTION P. 0. Box 1300 Vista, CA 92085 760-727-8540 Job Name : HME Whiptail Loop Building Location Whiptail Loop Carlsbad CA System : Area #2 Remote Contract Data File : HME Mezzanine System Area #2 Remote.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 VANGUARD FIRE PROTECTION Page 1 HME Whiptail Loop Date 11-19-16 HYDRAULIC CALCULATIONS for Project name: HME Whiptail Loop Location: Whiptail Loop Carlsbad CA Drawing no: Date: 8-12-17 Design Remote area number: Area #2 Remote Remote area location: Mezzanine Occupancy classification: Light Hazard Density: .10 - Gpm/SqFt Area of application: 945 - SqFt Coverage per sprinkler. VARIES - SqFt Type of sprinklers calculated: 5.6K QR-SSP No. of sprinklers calculated: 7 In-rack demand: N/A - GPM Hose streams: 100 -GPM Total water required (including hose streams): 243.529 -GPM Type of system: T I From Wet Grid Volume of dry orpreaction system: N/A - Gal Water supply information Date: 11-14-2016 Location: Whiptail Loop E of Gazelle Court Source: Carlsbad Fire Department © 82.508-Psi Name of contractor: Vanguard Fire Protection Address: P. 0. Box 1300 Vista, CA 92085 Phone number: 760-525-4329 Name of designer: VFP Authority having jurisdiction: Carlsbad Fire Department Notes: (Include peaking information or gridded systems here.) A 10% Reduction HAs Been Taken Prior To Data Entry. Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 VVdLI OU4)I L'UIV IL#) VANGUARD FIRE PROTECTION Page 2 HME Whiptail Loop Date 11-19-16 City Water Supply: Demand: CI - Static Iressure : 84.6 Dl - Elevation : 8.662 C2 - Residual Pressure: 50.4 D2 - System Flow : 143.529 C2 - Residual Flow : 8000 D2 - System Pressure : 82.508 Hose ( Demand) : 100 D3 - System Demand : 243.529 Safety Margin : 2.038 150 140 130 p120 R° E10° S90 SF 80 D3 U 70 R 60 - C2 E 50 40 30 - 20 10 DI -.I 1000 2000 3000 4000 5000 6000 7000 8000 9000 FLOW (NA 1.85) Comouter Proorams by Hvdratec Inc. Route 111 \Mndham N.H. USA 03087 riuw uitywiii VANGUARD FIRE PROTECTION Page 3 HME Whiptail Loop Date 11-19-16 20 SI *-AA 26.7 19.1, 52 +-88 I 77 19.1. S3 *- CC T I 11.2 19. $4 - DD T I 30.4 19. S5*-EE 23.3 56 *- FF t I 14.7 23Ø $7 4- GO 46.7 7.7 30.4 I00-~AA-+BB-,CC~-DD~-EE~- 110 t 26.7 11.2 50 I 46.7 I 8.6 38.2 I01-+ FF *- GO *-.. III 14.7 55.3 104*- 114 46.7 55.3 1004- 101*-- 102- 1034- 104 55.3 55.3 50 88.2 88.2 143.5 143.5 143.5 1104- 111 4- X - XT 4- 1124- 113+- 114*-- 115*-- 1164- 117<- 118*- MZa_ MZT 88.2 88.2 88.2 143.5 143.5 143.5 2.4 10 -+30 T I I 2.41 2.4 I 2.4, 11 -~ 31 1' I I 4.71 47 I 2.4.!. 12 .-+ 32 1' I I 7.11 7.1 Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 now Ljidyidm VANGUARD FIRE PROTECTION Page 4 HME Whiptail Loop Date 11-19-16 I 2.3. 13-33 T I I 9.4 14 34 12.2 2.9 -+35 15.1 128.4 1.51 -+ 36 f 16.f 127 1.71 4-. 37 1' 14.9 128.6 3 1 *--38 t I I.P 131.6 4- 39 7.9 7.9 - 200-+ 40 3.8 2.2 21 -+41 .t t 13.p 129.6 I 1.61 22 +-42 1 1 I 12.f 131.2 I 2.71 23 - 43 T .t I 9.61 134 I 4.21 24 -. 44 T t I 5.41 138.1 I 5.4 25 - 45 2.4 7.1 12.2 16.6 11.9 10 4-11 12 4-13 i.-14 4-15 +-16 17 .-18 4-19 +-20 4.7 9.4 15.1 14.9 7.9 11.7 12.3 5.4 200 21 -. 22 - 23 - 24 _ 25 13.9 9.6 ComDuter Proorams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 riuw LIdyldIII VANGUARD FIRE PROTECTION Page 5 HME Whiptail Loop Date 11-19-16 2.4 7.1 12.2 128.4 128.6 135.8 129.6 134 143.5 143.5 143.5 143.5 101.3 101.3 101.3 30 -,31 -332 -p33 -*34 .-)MZT-35 -36 ._37 -38 .-39 -40 +-41 -42 *-43 +-44 -45 -FM1- TR1+_BR1-BR2<_ MM- FLG+-DI .-UG1(-UGZ-BF1*-BF2+-CM1E-SRC 4.7 9.4 131.3 127 131.6 131.9 131.2 138.1 143.5 143.5 143.5 143.5 101.3 101.3 142.3 142.3 UGI3- BF34- BF44- CMZ- SRC 142.3 142.3 Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 r ILL11 19b USU OUIIIIIIdI VANGUARD FIRE PROTECTION Page 6 HME Whiptail Loop Date 11-19-16 Fitting Legend Abbrev. Name % % 1 1% 11/2 2 21/2 3 3% 4 5 6 8 10 12 14 16 18 20 24 -- B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F NFPA 13 45' Elbow I 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S NFPA 13 Swing Check 0 0 5 7 9 11 14 16 19 22 27 32 45 55 65 T NFPA 1390' Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zim Wilkins 375ADA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with * The fittings marked with a * show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a * will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Comouter Proarams by Hvdratec Inc. Route 111 Windham N.H. USA 03087 Pressur? / Flow Summary - STANDARD VANGUARD FIRE PROTECTION Page 7 HME Whiptail Loop Date 11-19-16 Node No. Elevation K-Fact Pt Actual Pn Flow Actual Density Area Press Req. SI 11.0 5.6 12.76 na 20.0 0.1 200 7.0 S2 11.0 5.6 11.52 na 19.01 0.1 170 7.0 S3 11.0 5.6 11.49 na 18.98 0.1 170 7.0 S4 11.0 5.6 11.73 na 19.18 0.1 168 7.0 S5 11.0 5.6 12.27 na 19.62 0.1 168 7.0 S6 11.0 5.6 17.34 na 23.32 0.1 168 7.0 S7 11.0 5.6 17.48 na 23.42 0.1 168 7.0 100 12.33 19.78 na Aft. 14.08 13.35 na BB 14.08 12.18 na CC 14.08 12.13 na DD 14.08 12.18 na EE 14.08 12.79 na 101 12.33 20.04 na FF 14.08 18.82 na GG 14.08 18.98 na 104 12.33 20.95 na 102 12.33 20.37 na 103 12.33 20.66 na 110 12.58 24.93 na 111 12.58 25.22 na X 12.58 25.99 na XT 12.58 32.86 na 112 12.33 54.25 na 113 12.33 54.48 na 114 12.33 54.71 na 115 12.33 55.27 na 116 12.33 55.83 na 117 12.33 56.39 na 118 12.33 56.97 na MZB 12.33 57.79 na 10 31.58 52.22 na 11 31.58 52.22 na 12 31.58 52.22 na 13 31.58 52.22 na 14 31.58 52.23 na 15 31.58 52.23 na 16 31.58 52.23 na 17 31.58 52.23 na 18 31.58 52.23 na 19 31.58 52.23 na 20 31.58 52.23 na 200 31.58 52.26 na 21 31.58 52.26 na 22 31.58 52.26 na 23 31.58 52.26 na 24 31.58 52.26 na 25 31.58 52.26 na 30 31.58 52.22 na 31 31.58 52.22 na 32 31.58 52.22 na 33 31.58 52.22 na 34 31.58 52.22 na MZT 31.58 52.22 na 35 31.58 52.22 na 36 31.58 52.23 na 37 31.58 52.23 na 38 31.58 52.24 na 39 31.58 52.24 na 40 31.58 52.25 na 41 31.58 52.26 na Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Flow Summary - Standard VANGUARD FIRE PROTECTION Page 8 HME Whiptail Loop Date 11-19-16 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 42 31.58 52.26 na 43 31.58 52.27 na 44 31.58 52.28 na 45 31.58 52.28 na FM1 31.58 52.29 na TRI 31.58 52.33 na BR1 2.0 65.17 na BR2 2.0 65.17 na MFD 2.0 65.18 na FLG 0.0 66.05 na Dl -4.0 67.79 na UGI -4.0 67.83 na 100.0 UG2 -4.0 67.93 na BFI -4.0 67.94 na BF2 -4.0 80.34 na CMI -9.0 82.51 na SRC -9.0 82.51 na BF3 -4.0 67.97 na BF4 -4.0 80.34 na CM2 -9.0 82.51 na The maximum velocity is 15.27 and it occurs in the pipe between nodes X and XT Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final, Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 9 HME Whiptail Loop Date 11-19-16 Hyd. Qa Dia. Filling Pipe Pt Pt Ref. "C" or Ftng's Pe Pv **** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Fin SI 20.00 1.049 1E 2.0 7.830 12.755 K Factor = 5.60 to 120.0 IT 5.0 7.000 -1.334 AA 20.0 0.1301 0.0 14.830 1.930 Vet = 7.42 0.0 20.00 13.351 K Factor = 5.47 S2 19.01 1.049 1E 2.0 9.750 11.525 K Factor= 5.60 to 120.0 IT 5.0 7.000 -1.334 BB 19.01 0.1184 0.0 16.750 1.984 Vet = 7.06 0.0 19.01 12.175 K Factor = 5.45 S3 18.98 1.049 1E 2.0 9.750 11.488 K Factor= 5.60 to 120.0 IT 5.0 7.000 -1.334 CC 18.98 0.1181 0.0 16.750 1.979 Vet = 7.05 0.0 18.98 12.133 KFactor= 5.45 S4 19.18 1.049 1E 2.0 7.750 11.732 K Factor = 5.60 to 120.0 IT 5.0 7.000 -1.334 DD 19.18 0.1205 0.0 14.750 1.777 Vel= 7.12 0.0 19.18 12.175 K Factor = 5.50 S5 19.62 1.049 1 2.0 7.750 12.275 K Factor = 5.60 to 120.0 IT 5.0 7.000 -1.334 EE 19.62 0.1256 0.0 14.750 1.852 VeI= 7.28 0.0 19.62 12.793 K Factor = 5.49 S6 23.32 1.049 1E 2.0 9.250 17.342 K Factor= 5.60 to 120.0 IT 5.0 7.000 -1.334 FE 23.32 0.1729 0.0 16.250 2.810 Vet = 8.66 0.0 23.32 18.818 K Factor = 5.38 S7 23.42 1.049 1 2.0 9.250 17.483 K Factor = 5.60 to 120.0 IT 5.0 7.000 -1.334 GG 23.42 0.1742 0.0 16.250 2.831 Vet = 8.69 0.0 23.42 18.980 K Factor= 5.38 100 -46.75 1.536 2T 20.216 37.830 19.781 to 120.0 0.0 20.216 -0.758 AA -46.75 -0.0977 0.0 58.046 -5.672 Vet = 8.09 AA 20.00 1.536 4E 20.216 13.580 13.351 to 120.0 0.0 20.216 0.0 BB -26.75 -0.0348 0.0 33.796 -1.176 Vet = 4.63 BB 19.01 1.536 0.0 12.000 12.175 to 120.0 0.0 0.0 0.0 CC -7.74 -0.0035 0.0 12.000 -0.042 Vet = 1.34 CC 18.98 1.536 0.0 6.000 12.133 to 120.0 0.0 0.0 0.0 DD 11.24 0.0070 0.0 6.000 0.042 Vel= 1.95 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calcylations - Hazen-Williams VANGUARD FIRE PROTECTION Page 10 HME Whiptail Loop Date 11-19-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn DO 19.19 1.536 0.0 14.000 12.175 to 120.0 0.0 0.0 0.0 EE 30.43 0.0441 0.0 14.000 0.618 Vet = 5.27 EE 19.61 1.536 4T 40.432 63.170 12.793 to 120.0 0.0 40.432 0.650 110 50.04 0.1109 0.0 103.602 11.485 Vet= 8.66 0.0 50.04 24.928 K Factor = 10.02 101 -8.58 1.536 2T 20.216 69.500 20.043 to 120.0 4E 20.216 40.432 -0.758 FF -8.58 -0.0042 0.0 109.932 -0.467 Vel = 1.49 FE 23.32 1.536 0.0 14.000 18.818 to 120.0 0.0 0.0 0.0 GG 14.74 0.0116 0.0 14.000 0.162 Vel= 2.55 GG 23.41 1.536 2T 20.216 63.170 18.980 to 120.0 0.0 20.216 0.650 111 38.15 0.0671 0.0 83.386 5.594 VeI= 6.61 0.0 38.15 25.224 K Factor = 7.60 104 55.33 1.536 4E 20.216 192.250 20.946 to 120.0 4T 40.432 60.648 0.0 114 55.33 0.1335 0.0 252.898 33.759 Vet = 9.58 0.0 55.33 54.705 K Factor = 7.48 100 46.75 2.157 0.0 14.000 19.781 to 120.0 0.0 0.0 0.0 101 46.75 0.0187 0.0 14.000 0.262 VeI= 4.10 101 8.58 2.157 0.0 12.670 20.043 to 120.0 0.0 0.0 0.0 102 55.33 0.0256 0.0 12.670 0.324 Vet = 4.86 102 0.0 2.157 0.0 11.330 20.367 to 120.0 0.0 0.0 0.0 103 55.33 0.0255 0.0 11.330 0.289 Vet = 4.86 103 0.0 2.157 0.0 11.330 20.656 to 120.0 0.0 0.0 0.0 104 55.33 0.0256 0.0 11.330 0.290 Vet = 4.86 0.0 55.33 20.946 KFactor= 12.09 110 50.04 2.157 0.0 14.000 24.928 to 120.0 0.0 0.0 0.0 111 50.04 0.0211 0.0 14.000 0.296 VeI= 4.39 111 38.16 2.157 0.0 12.670 25.224 to 120.0 0.0 0.0 0.0 X 88.2 0.0605 0.0 12.670 0.767 VeI= 7.74 X 0.0 1.536 2T 20.216 1.500 25.991 to 120.0 0.0 20.216 0.0 XT 88.2 0.3163 0.0 21.716 6.868 Vet = 15.27 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final, Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 11 HME Whiptail Loop Date 11-19-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn XT 0.0 1.536 2T 20.216 47.080 32.859 to 120.0 0.0 20.216 0.108 112 88.2 0.3162 0.0 67.296 21.281 Vel = 15.27 112 0.0 2.703 0.0 11.330 54.248 to 120.0 0.0 0.0 0.0 113 88.2 0.0202 0.0 11.330 0.229 Vel = 4.93 113 0.0 2.703 0.0 11.330 54.477 to 120.0 0.0 0.0 0.0 114 88.2 0.0201 0.0 11.330 0.228 Vel = 4.93 114 55.33 2.703 0.0 11.330 54.705 to 120.0 0.0 0.0 0.0 115 143.53 0.0497 0.0 11.330 0.563 VeI= 8.02 115 0.0 2.703 0.0 11.330 55.268 to 120.0 0.0 0.0 0.0 116 143.53 0.0496 0.0 11.330 0.562 VeI= 8.02 116 0.0 2.703 0.0 11.330 55.830 to 120.0 0.0 0.0 0.0 117 143.53 0.0497 0.0 11.330 0.563 VeI= 8.02 117 0.0 2.703 0.0 11.670 56.393 to 120.0 0.0 0.0 0.0 118 143.53 0.0496 0.0 11.670 0.579 VeI= 8.02 118 0.0 2.703 1 9.325 7.170 56.972 to 120.0 0.0 9.325 0.0 MZB 143.53 0.0497 0.0 16.495 0.819 Vel = 8.02 MZB 0.0 2.703 1E 9.325 27.670 57.791 to 120.0 iT 18.651 27.976 -8.337 MZT 143.53 0.0497 0.0 55.646 2.763 Vel = 8.02 0.0 143.53 52.217 K Factor= 19.86 10 -2.36 2.703 4E 37.301 145.670 52.223 to 120.0 4T 74.603 111.904 0.0 30 -2.36 0.0 0.0 257.574 -0.006 Vel = 0.13 0.0 -2.36 52.217 K Factor = -0.33 11 -2.37 2.703 4E 37.301 145.670 52.223 to 120.0 4T 74.603 111.904 0.0 31 -2.37 0.0 0.0 257.574 -0.006 Vel = 0.13 0.0 -2.37 52.217 K Factor -0.33 12 -2.39 2.703 4E 37.301 145.670 52.223 to 120.0 4T 74.603 111.904 0.0 32 -2.39 0.0 0.0 257.574 -0.006 VeI = 0.13 0.0 -2.39 52.217 K Factor= -0.33 13 -2.28 2.703 8E 74.603 143.920 52.224 to 120.0 4T 74.603 149.206 0.0 33 -2.28 0.0 0.0 293.126 -0.007 Vel = 0.13 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FinI Caloulations - Hazen-Williams VANGUARD FIRE PROTECTION Page 12 HME Whiptail Loop Date 11-19-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv **** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Fin 0.0 -2.28 52.217 K Factor= -0.32 14 -2.82 2.703 4E 37.301 160.830 52.226 to 120.0 4T 74.603 111.904 0.0 34 -2.82 0.0 0.0 272.734 -0.009 Vel = 0.16 0.0 -2.82 52.217 KFactor= -0.39 15 -2.86 2.703 4T 74.603 145.500 52.227 to 120.0 0.0 74.603 0.0 35 -2.86 0.0 0.0 220.103 -0.008 Vel = 0.16 0.0 -2.86 52.219 K Factor= -0.40 16 -1.49 2.703 4T 74.603 145.500 52.228 to 120.0 0.0 74.603 0.0 36 -1.49 0.0 0.0 220.103 -0.003 Vel = 0.08 0.0 -1.49 52.225 K Factor= -0.21 17 1.69 2.703 4T 74.603 145.500 52.228 to 120.0 0.0 74.603 0.0 37 1.69 0.0 0.0 220.103 0.003 Vel = 0.09 0.0 1.69 52.231 K Factor = 0.23 18 2.99 2.703 4T 74.603 145.500 52.229 to 120.0 0.0 74.603 0.0 38 2.99 0.0 0.0 220.103 0.009 Vel = 0.17 0.0 2.99 52.238 K Factor = 0.41 19 4.00 2.703 4T 74.603 145.500 52.230 to 120.0 0.0 74.603 0.0 39 4.0 0.0001 0.0 220.103 0.014 Vel = 0.22 0.0 4.00 52.244 K Factor= 0.55 20 7.88 2.703 4T 74.603 58.000 52.230 to 120.0 0.0 74.603 0.0 200 7.88 0.0002 0.0 132.603 0.030 Vel = 0.44 200 -11.67 2.703 41 74.603 89.500 52.260 to 120.0 0.0 74.603 0.0 40 -3.79 -0.0001 0.0 164.103 -0.009 Vel = 0.21 0.0 -3.79 52.251 K Factor= -0.52 21 -2.23 2.703 4T 74.603 89.500 52.261 to 120.0 0.0 74.603 0.0 41 -2.23 0.0 0.0 164.103 -0.004 Vel = 0.12 0.0 -2.23 52.257 K Factor= -0.31 22 1.61 2.703 4T 74.603 89.500 52.262 to 120.0 0.0 74.603 0.0 42 1.61 0.0 0.0 164.103 0.002 VeI= 0.09 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FiraI Calculations - Hazen-Williams VANGUARD FIRE PROTECTION Page 13 HME Whiptait Loop Date 11-19-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 1.61 52.264 K Factor = 0.22 23 2.72 2.703 4T 74.603 89.500 52.264 to 120.0 0.0 74.603 0.0 43 2.72 0.0 0.0 164.103 0.005 VeI= 0.15 0.0 2.72 52.269 K Factor= 0.38 24 4.18 2.703 4T 74.603 89.500 52.264 to 120.0 0.0 74.603 0.0 44 4.18 0.0001 0.0 164.103 0.012 Vet = 0.23 0.0 4.18 52.276 K Factor= 0.58 25 5.39 2.703 4T 74.603 89.500 52.264 to 120.0 0.0 74.603 0.0 45 5.39 0.0001 0.0 164.103 0.019 Vel = 0.30 0.0 5.39 52.283 K Factor= 0.75 10 2.36 4.31 0.0 9.670 52.223 to 120.0 0.0 0.0 0.0 11 2.36 0.0 0.0 9.670 0.0 Vet = 0.05 11 2.37 4.31 0.0 9.750 52.223 to 120.0 0.0 0.0 0.0 12 4.73 0.0 0.0 9.750 0.0 Vet= 0.10 12 2.39 4.31 0.0 12.500 52.223 to 120.0 0.0 0.0 0.0 13 7.12 0.0001 0.0 12.500 0.001 Vel = 0.16 13 2.27 4.31 4E 55.748 21.670 52.224 to 120.0 0.0 55.748 0.0 14 9.39 0.0 0.0 77.418 0.002 Vel = 0.21 14 2.83 4.31 0.0 11.670 52.226 to 120.0 0.0 0.0 0.0 15 12.22 0.0001 0.0 11.670 0.001 Vet = 0.27 15 2.86 4.31 0.0 10.000 52.227 to 120.0 0.0 0.0 0.0 16 15.08 0.0001 0.0 10.000 0.001 Vel = 0.33 16 1.49 4.31 0.0 9.000 52.228 to 120.0 0.0 0.0 0.0 17 16.57 0.0 0.0 9.000 0.0 Vet= 0.36 17 -1.69 4.31 0.0 10.000 52.228 to 120.0 0.0 0.0 0.0 18 14.88 0.0001 0.0 10.000 0.001 Vet = 0.33 18 -2.99 4.31 0.0 10.000 52.229 to 120.0 0.0 0.0 0.0 19 11.89 0.0001 0.0 10.000 0.001 Vet = 0.26 19 -4.01 4.31 0.0 9.500 52.230 to 120.0 0.0 0.0 0.0 20 7.88 0.0 0.0 9.500 0.0 Vel = 0.17 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final CaLpulations - Hazen-Williams VANGUARD FIRE PROTECTION Page 14 HME Whiptail Loop Date 11-19-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv **** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 0.0 7.88 52.230 K Factor= 1.09 200 11.67 4.31 0.0 10.000 52.260 to 120.0 0.0 0.0 0.0 21 11.67 0.0001 0.0 10.000 0.001 Vet = 0.26 21 2.24 4.31 0.0 10.000 52.261 to 120.0 0.0 0.0 0.0 22 13.91 0.0001 0.0 10.000 0.001 Vet = 0.31 22 -1.62 4.31 IT 27.874 8.000 52.262 to 120.0 0.0 27.874 0.0 23 12.29 0.0001 0.0 35.874 0.002 Vel = 0.27 23 -2.72 4.31 0.0 10.000 52.264 to 120.0 0.0 0.0 0.0 24 9.57 0.0 0.0 10.000 0.0 Vel = 0.21 24 -4.18 4.31 0.0 10.000 52.264 to 120.0 0.0 0.0 0.0 25 5.39 0.0 0.0 10.000 0.0 VeI= 0.12 0.0 5.39 52.264 K Factor= 0.75 30 -2.36 6.357 0.0 9.670 52.217 to 120.0 0.0 0.0 0.0 31 -2.36 0.0 0.0 9.670 0.0 Vel = 0.02 31 -2.37 6.357 0.0 9.750 52.217 to 120.0 0.0 0.0 0.0 32 -4.73 0.0 0.0 9.750 0.0 Vel = 0.05 32 -2.39 6.357 0.0 12.500 52.217 to 120.0 0.0 0.0 0.0 33 -7.12 0.0 0.0 12.500 0.0 Vel = 0.07 33 -2.27 6.357 0.0 12.420 52.217 to 120.0 0.0 0.0 0.0 34 -9.39 0.0 0.0 12.420 0.0 Vel = 0.09 34 -2.83 6.357 0.0 6.170 52.217 to 120.0 0.0 0.0 0.0 MZT -12.22 0.0 0.0 6.170 0.0 Vel = 0.12 MZT 143.53 6.357 0.0 3.500 52.217 to 120.0 0.0 0.0 0.0 35 131.31 0.0006 0.0 3.500 0.002 Vel = 1.33 35 -2.86 6.357 0.0 10.000 52.219 to 120.0 0.0 0.0 0.0 36 128.45 0.0006 0.0 10.000 0.006 Vel = 1.30 36 -1.49 6.357 0.0 10.000 52.225 to 120.0 0.0 0.0 0.0 37 126.96 0.0006 0.0 10.000 0.006 Vet = 1.28 37 1.69 6.357 0.0 10.000 52.231 to 120.0 0.0 0.0 0.0 38 128.65 0.0007 0.0 10.000 0.007 Vet = 1.30 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 FipakCacu(ations - Hazen-Williams VANGUARD FIRE PROTECTION Page 15 HME Whiptail Loop Date 11-19-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ***** Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 38 2.99 6.357 0.0 10.000 52.238 to 120.0 0.0 0.0 0.0 39 131.64 0.0006 0.0 10.000 0.006 VeI= 1.33 39 4.01 6.357 0.0 9.500 52.244 to 120.0 0.0 0.0 0.0 40 135.65 0.0007 0.0 9.500 0.007 Vet = 1.37 40 -3.79 6.357 0.0 10.000 52.251 to 120.0 0.0 0.0 0.0 41 131.86 0.0006 0.0 10.000 0.006 VeI= 1.33 41 -2.24 6.357 0.0 10.000 52.257 to 120.0 0.0 0.0 0.0 42 129.62 0.0007 0.0 10.000 0.007 Vel= 1.31 42 1.62 6.357 0.0 8.000 52.264 to 120.0 0.0 0.0 0.0 43 131.24 0.0006 0.0 8.000 0.005 Vel = 1.33 43 2.72 6.357 0.0 10.000 52.269 to 120.0 0.0 0.0 0.0 44 133.96 0.0007 0.0 10.000 0.007 Vet = 1.35 44 4.18 6.357 0.0 10.000 52.276 to 120.0 0.0 0.0 0.0 45 138.14 0.0007 0.0 10.000 0.007 Vet = 1.40 45 5.39 6.357 0.0 4.000 52.283 to 120.0 0.0 0.0 0.0 FMI 143.53 0.0008 0.0 4.000 0.003 Vel = 1.45 FM1 0.0 8.249 1E 21.141 168.830 52.286 to 120.0 0.0 21.141 0.0 TRI 143.53 0.0002 0.0 189.971 0.041 Vel = 0.86 IRl 0.0 8.249 1S 52.853 27.080 52.327 to 120.0 1 14.094 108.055 12.811 BRI 143.53 0.0002 1 41.108 135.135 0.030 VeI= 0.86 BR1 0.0 8.249 0.0 1.500 65.168 to 120.0 0.0 0.0 0.0 BR2 143.53 0.0 0.0 1.500 0.0 Vel= 0.86 BR2 0.0 8.249 IT 41.108 0.750 65.168 to 120.0 0.0 41.108 0.0 MFD 143.53 0.0002 0.0 41.858 0.009 Vel= 0.86 MED 0.0 8.249 IE 21.141 3.670 65.177 to 120.0 0.0 21.141 0.866 FLG 143.53 0.0002 0.0 24.811 0.006 VeI= 0.86 FLG 0.0 8.27 IE 28.468 10.000 66.049 to 140.0 0.0 28.468 1.732 Dl 143.53 0.0002 0.0 38.468 0.006 Vet = 0.86 Dl 0.0 7.68 1G 5.012 118.000 67.787 to 150.0 IT 43.857 93.979 0.0 UGI 143.53 0.0002 2E 45.11 211.979 0.043 Vet = 0.99 UG1 -42.27 7.68 5F 56.388 798.000 67.830 Qa = 100 to 150.0 iT 43.857 150.367 0.0 UG2 101.26 0.0001 2E 45.11 948.367 0.101 VeI= 0.70 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fina' CIciIations - Hazen-Williams VANGUARD FIRE PROTECTION Page 16 HME Whiptail Loop Date 11-19-16 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftngs Pe Pv ******* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1G 5.012 UG2 0.0 7.68 1E 22.555 69.000 67.931 to 150.0 0.0 22.555 0.0 BF1 101.26 0.0001 0.0 91.555 0.010 Vel = 0.70 BFI 0.0 8.27 IT 55.354 20.000 67.941 to 140.0 2E 56.936 112.290 12.387 *Fixed loss 12.387 BF2 101.26 0.0001 IZim 0.0 132.290 0.012 VeI= 0.60 BF2 0.0 11.2 1 6.645 55.000 80.340 to 150.0 iT 66.446 73.090 2.166 CM1 101.26 0.0 0.0 128.090 0.001 Vel = 0.33 CM1 0.0 15.94 IG 14.305 255.000 82.507 to 140.0 0.0 14.305 0.0 SRC 101.26 0.0 0.0 269.305 0.001 Vel= 0.16 0.0 101.26 82.508 K Factor = 11.15 UG1 142.27 7.68 5F 56.388 575.000 67.830 to 150.0 1 43.857 100.245 0.0 BF3 142.27 0.0002 0.0 675.245 0.135 Vel = 0.99 BF3 0.0 8.27 iT 55.354 20.000 67.965 to 140.0 2E 56.936 112.290 12.349 * Fixed loss 12.349 BF4 142.27 0.0002 iZim 0.0 132.290 0.021 Vel = 0.85 BF4 0.0 11.2 IF 14.397 62.000 80.335 to 150.0 IG 6.645 87.487 2.166 CM2 142.27 0.0 IT 66.446 149.487 0.005 Vel = 0.46 CM2 0.0 15.94 3G 42.916 340.000 82.506 to 140.0 0.0 42.916 0.0 SRC 142.27 0.0 0.0 382.916 0.002 Vel = 0.23 0.0 142.27 82.508 KFactor = 15.66 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Bulletin 172 Rev, F R liabl Model JL112 & J112 ECLH/ECOH Pendent & Recessed Pendent (SIN R7216 - Link and RA7216 -Bulb) Quick Response for Light Hazard (16'x 16'(4.9m x 4.9m), 18'x 18'(5.5m x 5.5m) and 20' x 20' (6.1m x 6.l m) spacing) Quick Response for Ordinary Hazard (12'x 12'(3.7m x 3.7m) and 14'x 14'(4.3m x 4.3m) spacing) Standard Response for Ordinary Hazard (16' x 16'(4.9m x 4.9m), 18'x 18' (5.5m x 5.5m) and 20' x 20' (6.1m x 6.l m) spacing) Features 1 Extended Coverage Ordinary Hazard and Light Hazard protection to 400 ft' (37.2 m2) per sprinkler. Nominal K= 11.2 (160). Available in Pendent or Recessed Pendent styles. Recessed pendent version provides 3%" (19mm) adjust- ment to flush pendent position (see adjustment table). Available in brass, chrome, polyester coated and Electroless Nickel PTFE (Teflon®)* plated For applications as per NFPA 13. - Approvals Organizations Underwriters Laboratories, Inc. (UL) Underwriters Laboratories of Canada (cULus) UL Listing Category Sprinklers, Automatic and Open Extended Coverage Sprin- klers-Ordinary Hazard Occupancy UL Guide Number - VNIV. The Reliable Model JL1 12 and J112 sprinkler are Extended Coverage Sprinklers for use in both Light and Ordinary Hazard 1 and 2 occupancies with a coverage area of up to 400 square feet (37.2m2) per sprinkler. For all light hazard applications it is a Quick Response sprin- kler. For ordinary hazard applications, it is a Standard Re- sponse sprinkler when the spacing is 16' x 16' (4.9m x 4.9m) and larger. When the spacing is 12'x 12'(3.7m x 3.7m) or 14'x 14'(4.3m x 4.3m), the sprinkler is Quick Response for ordinary hazard applications. The use of ECLH/ECOH sprinklers can provide lower instal- lation costs by requiring fewer sprinklers, less piping and re- duced labor. ECLH/ECOH sprinklers are to be installed according to the design criteria shown in this bulletin, NFPA 13, and all other lo- cal codes and ordinances. Flows and pressures as shown on pages 2 and 3 of this bulletin, must be used for the appropriate spacing and for the designated hazard classifications. 'DuPont Registered Trademark ModelJL112&J112-Pendent 03 ECLH - Extended Coverage Ught Hazad ?' SIN RA7216 is Corrosion Resistant with White or Black Polyester Coating or Electroless Nickel PTFE (Teflon®)* plating. ivioaeu ini z renaeni (RA7216) - Bulb (R7216) - Link This ECLH/ECOH sprinkler is available in various finishes, which includes a white polyester corrosion resistant finish. ECLH/ECOH sprinklers are available in a pendent or an attractive recessed pendent type which provides up to 34" (19mm) of escutcheon adjustment. Design Criteria Reliable Model JL112 & J112 ECLH/ECOH sprinklers shall only be used in systems designed and installed in accordance with NFPA 13 and all other local codes and ordinances. The following design criteria also apply: Minimum sprinkler spacing is 8 ft (2.44m). Sprinklers have a minimum flow requirement for each spacing as shown in the Flow Requirements Table on the reverse side. Sprinklers are only to be used in systems hydraulically designed per NFPA 13. Deflector to commodity clearance shall be a minimum of 18 inches (457mm). ECOH sprinklers shall be installed in unobstructed construction as defined in NFPA 13. ECOH sprinklers which are installed above the bottom of a horizontal obstruction, shall have their deflectors located as shown in the Obstruction Table on page 3. Sprinklers can be installed under a sloping ceiling not exceeding 2 inches (50.8mm) of rise in 12 inches (304.5mm). Maximum working pressure is 175 psi (12.1 bar) at the sprinkler. The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Sprinkler Model Specifications Temperature Max. Maximum Maximum Sprinkler Model Type Rating Ceiling Temp. Sprinkler Coverage THD Approvals Spacing Area Size OF °C OF °c ft (m) ft2 (m2) JL112 ECLH/ECOH- R7216 Link/Pendent 165 212 74 100 100 150 38 66 20(6.1) 400 (37.2) 34"NPT JL1 12 ECLH/ECOH- R7216 Link/Recessed J112 ECLH/ECOH- RA7216 Bulb/Pendent 155 200 68 93 100 150 38 66 20(6.1) 400 (37.2) ( 19mm) 1,2 J112 ECLH/ECOH- RA7216 Bulb/Recessed Flow Requirements - Light Hazard - Quick Response Spacing tt4m) Coverage Area .W4m2 Flow .gpm1pm) Pressure -psi -(bar) "K" Factor us Metiic 16 x 16(4.9 x 4.9) 256 (23.8) 30(113.6) 7.2(0.5) 11.2 12.8 (0.9) 160.0 18x18(55-x55) 324(30.1.) 33(124.9) 8.7(0.6) 20x20(6.1 x6.1) 400(37.2) 40(151.4) Flow Requirements- Ordinary Hazard - Standard Response Ordinary Hazard 1 Ordinary Hazard 2 0.15 gpm/ft2 (6.1 L/minlm2) 0.20 gpm/ft2 (8.1 lJmin/m2) Spacing Coverage "K" Factor ft (m) Area Density Density Flow Pressure Flow Pressure US Metric ft2 (ms) gpm (Lpm) psi (bar) gpm (1pm) psi (bar) 16 x 16 (4.9 x 4.9) 256 (23.8) 39 (147.6) 12.1 (0.8) 51 (193.0) 20.7 (1.4) 11.2 160.0 18x 18(5.5x5.5) 324(30.1) 49(185.5) 19.1 (1.3) 65(246.0) 33.7(2.3) 20x20(6.1 x6.1) 400(37.2) 60(227.1) 28.7(2.0) 80(302.8) 51.0(3.5) Flow Requirements - Ordinary Hazard - Quick Response Ordinary Hazard 1 Ordinary Hazard 2 0.15 gpm1ft2 (6.1 L/rnin/rn2) 0.20gpmfft2 (8.1 Umin/m Spacing Coverage "K" Factor ft (m) Area Density Density Flow Pressure Flow Pressure US Metric ft2 (m2) gpm (Lpm) psi (bar) gpm (Lpm) psi (bar) 14x 14(4.3x4.3) 196(18.2) 30 (113.6) I 7.2(0.5) 39 (147.6) 12.1 (0.8) 11.2 I 160.0 12x 12(3.7x3.7) 144(13.4) 2. Recess Escutcheons F1/F2 FP Model Ji Sprinkler Wrench Use Model Ji Wrench for JL112& J112 ECLH/ECOH Pendent Sprinkler Removal and Installation .I'ATlTT I Model RJ Sprinkler Wrench Use Model RJ Wrench for JL1 12 & J 112 ECLH/ECOH Recessed Sprinkler Removal and Installation RJ Wrench Recessed Pendent ECLH/ECOH Adjustments (1) Escutcheon ECLH ECOH R7216 RA7216 R7216 RA7216 FP A(19.0) /4(19.0) /4(19.0) /4(19.0) Fl ' A(19.0) %(19.0) F2 ½(12.7) ½(12.7) 1 1/2 (12.7) ½(12.7) Adjustments in inches (mm). (2) Not listed by UL or cULus. Finishes Sprinkler Finishes Sprinkler Escutcheon Bronze Brass Chrome Chrome White and Black Polyester Coated (2) White Painted Special Application Finishes Sprinkler I Escutcheon Electroless Nickel PTFE(Teflon®)*)l)(a Electroless Nickel PTFE (Teflon®)* (1) RA7216 Only 2) Corrosion Resistant Ordering Information Sprinkler Model Temperature Rating Finish Escutcheon and finish (where applicable) Corrosion Resistant J112 ECLH/ECOH Bulb 155 200 68 93 Minimum Flow Requirements For Earlier Editions of NFPA 13- FOR REFERENCE ONLY NFPA13 - 1991 Requirements NFPA13 - 1989 Requirements "K" Factor Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 1 Ordinary Hazard 2 Ordinary Hazard 3 0.15 gpm/ft2 0.20 gpmfft2 0.16 gpm1ft2 0.19 gprn1ft2 0.21 gpm/tt2 Spacing Coverage (6.1 L/mln/m2) (8.1 L/mln/m2) (6.6 L/min/m2) (7.7 L/min/m2) (8.6 Llminlm2) ft (M) Area Density Density Density Density Density US Metric ft2(m2) R ow Pressure Row Pressure . Flow Pressure Row Pressure Flow Pressure gpm psi m) (Lpm) psi gpm psi gpm psi gpm psi (bar) (Lpm) (bar) (bar) (Lpm) (bar) (Lpm) (bar) (Lpm) 14x 14 (4.3x4.3) 196(18.2) 30.2 7.0 39.2 11.9 31.4 7.6 37.3 10.7 41.2 13.0 and less (114,3) (0.48) (148.3) (0.82) (118.8) (0.52) (141.2) (0.74) (155.9) (0.90) 16x 16 256(23.8) 38.4 11.4 51.2 20.2 41.0 12.9 48.7 18.2 53.8 22.3 (4.9x4.9) (145.3) (0.79) (193.8) (1.39) (155.2) (0.89) (184.3) (126) (203.6) (1.54) 11.4 164.4 18 x 18 324(30.1) 48.6 18.2 64.8 32.3 51.9 20.7 61.6 29.2 68.0 35.7 (184.0) (1.24) (258.9) (2.23) (196.4) (1.43) (233.2) (2.01) (257.4) (2.46) 20x20 400(37.2) 60.0 27.7 80.0 49.3 64.0 31.5 76.0 44.5 84.0 54.3 (6.1 x6.1) (227.1) (1.91) (302.8) (3.40) (242.2) (2.17) (287.7) (3.07) 1 (317.9) 1 (3.75) 1 *DuPont Registered Trademark 3. Installation Requirements for Under Concrete Tees - cULus The stems of the concrete tee construction must be spaced at less than 7.5 feet (2.3m) on center but more than 3 feet (0.9m) on center. The depth of the concrete tees must not exceed 30 inches (762mm). The maximum permitted concrete tee length is 32 feet (9.8m); however, where the concrete tee length exceeds 32 feet (9.8m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the longitudinal space between the tees does not exceed 32 feet (9.8m) in length. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25.4mm) below the bottom of the concrete tee stems. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (25.4mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler discharge criteria requirements of NFPA13 for extended coverage upright sprinkler applies. Lessthan 1 ..................................................................... 0" (Less than 0.305m ...................................................0mm) 1'to less than l'-6 ......................................................... 0" (0.305m to less than 0.305m - 152.4mm .................. 0mm) 1 - 6" to less than 2'.......................................................1 (0.305m - 152.4mm to less than 0.61m ............... 25.4mm) 2' to less than 2' -6 ........................................................ 1" (0.61m to less than 061m - 152.4mm..................25.4mm) 2-6" to less than 3'.......................................................1" (0.61m - 152.4mm to less than 0.915m ............... 25,4mm) 3' to less than 3' - 6".......................................................3" (0.915m to less than 0.915m - 152.4mm.............76.2mm) 3' - 6" to less than 4'.......................................................4" (0.915m - 152.4mm to less than 1.22m ............101.6mm) 4' to less than 4' - 6".......................................................5" (1.22m to less than 1.22m- 152.4mm..................127mm) -6" to less than 5' .......................................................7" (1.22m - 152.4mm to less than 1.525m ............177.8mm) to less than 5-6" ......................................................7" (1.525m to less than 1.525m - 152.4mm...........177.8mm) 5'- 6" to less than 6' ......................................................7" (1.525m - 152.4mm to less than 1.83m ............177.8mm) to less than 6' - 6".......................................................9" (1.83m to less than 1.83m - 152.4mm...............228.6mm) 6'-6" to less than 7' ....................................................11" (1.83m - 152.4mm to less than 2.135m ............279.4mm) and greater ..............................................................14" (2.135m and greater .........................................355.6mm) —1 1$116-Ot4 t.4I? tt REDUCER Rr AGUWST SFR!RKLER I WaDDER BUSS 3/8[1503] D.. TO CEILING E65D 2 22/J2 OLD Fig. 1 - Fl Escutcheon Location of Deflector to Horizontal Obstruction I Maximum Allowable Distance Distance from Sprinkler Deflector Above Bottom of to Side of Obstruction I Obstruction Solder Link Bulb Classification OF °C Link Color Classification OF °C Bulb Color Ordinary Intermediate 165 212 74 100 Black* White Ordinary Intermediate 155 200 68 93 Red Green * 165°F chrome plated and white painted sprinklers will contain a white painted solder link. The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States, Canada and foreign countries. Manufactured by The Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices Reliable (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address eRecycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 01/14 PN 9999970310 Bulletin 014 Rev. P ble Model Fl FR Series Quick Response Glass Bulb Sprinklers Model Fl FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall Horizontal Sidewall Model F1FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent Horizontal Sidewall Model F1FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fl FR42, Fl FRXLH & Fl FR28 Sprinkler Types Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Upright Pendent/Fl/F2 Standard Spray Pendent .v I Model F1FR40 Sprinkler Types Standard Spray Pendent UjI Standard Spray Pendent __ I .1 i i Model F1FR42, F1FR40, F1FRXLH & F1FR28 /& I Recessed Sprinkler Types I Model F1FR56LL & F1FR42LL Low Lead Sprinkler Recessed Concealed Recessed Types Horizontal Sidewall Pendent Pendent/FP I Standard Spray Pendent with less than 0.25% Lead Content _______H_H_______ Listing & Approvals The following organizations provide Listings or Approvals for various Model Fl FR series sprinklers. See the Design and Installation table in this Bulletin for information on XLH Upright XLH Pendent XLH Recessed specific listings and approvals applicable to each sprin- Pendent Fl/F2 kler. Product Description I Underwriters Laboratories Inc. and Certified for Reliable Model F1 FR series sprinklers I Canada (cULus) in accordance with ANSl/UL199. are quick-response automatic sprin- I FM Approvals (FM) klers with a glass bulb thermal element. I Loss Prevention Certification Board (LPCB) Model Fl FR series sprinklers are Stan- I VdS Schadenverhutung GmbH (VdS) dard Spray sprinklers, with the excep- Underwriters Laboratories Inc. and Underwriters tion of the Model F1FR56 Conventional XLH Recessed Laboratories of Canada Certified for Health Effects sprinkler which is an Old-style/Conven- Pendent FP to NSF/ANSI Standard 61 Annex C (ULH) tional sprinkler. EC Certificate: 0786-CPD-40239 (RA1414), 0786- The Model F1FR Series automatic sprinklers utilize a 3.0 CPD-40251 (RA1 425), 0786-CPD-40252 (RA1 475) mm frangible glass bulb. These sprinklers have demonstrat- (EC) ed response times in laboratory tests which are five to ten UL Listing Category times faster than standard response sprinklers. This quick Sprinklers, Automatic & Open (VNlV) response enables the Model Fl FR Series sprinklers to apply Quick Response Sprinkler water to a fire faster than standard-response sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. Model Fl FR Series sprinklers provide a wide range of op- tions where quick-response, glass bulb sprinklers are used: Pendent, recessed pendent, upright, horizontal sidewall, and vertical sidewall deflectors K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 metric), and 5.6 (80 metric) Flush, recessed, and concealed installations See the Design and Installation Information table in this Bulletin for information on the approvals and availability of specific Model Fl FR series sprinkler configurations. Model Fl FR Recessed Pendent and Recessed Horizon- tal Sidewall sprinklers are required to be used with Reliable Model Fl, F2, or FP recessed escutcheons. See the Re- cessed Escutcheon Data table in this Bulletin for listing and approval information with each specific Model Fl FR series sprinkler. Model Fl and F2 recessed escutcheons, shown in Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. Model FP recessed escutcheons, shown in Fig. 2, provide a 1/2-inch (12.7mm) threaded adjustment. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers are required to be used with Model CCP cover plates. A standard profile Model CCP cov- er plate is available that provides up to 1/2-inch (12.7mm) of cover plate adjustment. In addition, a low profile Model CCP cover plate is also available that provides up to 5/16-inch (8.0mm) of cover plate adjustment. See the Design and In- stallation Information and Listed and Approved Temperature Ratings tables in this Bulletin for further information on ap- proved cover plate options. Application Model F1FR Series sprinklers are intended for use in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and the requirements of the Authority Hav- ing Jurisdiction. Care must be exercised that the k-factor, temperature rating, deflector style, and sprinkler type are in accordance with the requirements of the applicable design and installation standards. In addition, Model F1 FR Series sprinklers must be used in accordance with their listings and approvals, as well as the information provided in this Bulletin. Installation Glass bulb sprinklers have orange bulb protectors or pro- tective caps to minimize bulb damage during shipping, han- dling and installation. Reliable sprinkler installation wrench- es are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprin- kler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vul- nerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Model F1 FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in the Design and Installation Information table in this Bulletin. Any other wrench may damage the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N-m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Recessed Sprinklers Model Fl FR Series Recessed sprinklers are to be installed as shown in Fig. 1, Fig. 2, or Fig. 3, as applicable to the spe- cific model being installed. The Recessed Escutcheon Data table in the Bulletin identifies the only recessed escutcheons that are permitted to be used with each Model Fl FR Series Recessed sprinkler. The use of any other recessed escutch- eon will void all approvals and negate all warranties. Concealed Sprinklers Model Fl FR Series Concealed Pendent sprinklers are to be installed as shown in Fig. 4 or Fig. 5, as applicable to the selected cover plate. Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers have a factory-installed Model CCP cup. A protective cap is in- stalled at the factory that should remain on the sprinkler until the sprinkler is installed and should then be reinstalled on the sprinkler until the cover plate is installed. The concealed sprinkler assemblies are completed by the installation of a Model CCP push-on/thread-off cover plate assembly. The cover plate and sprinkler cup assemblies are joined using a cover plate skirt with flexible tabs for threaded engage- ment. A choice of two Model CCP cover plate assemblies provides either 1/2-inch (13mm) or 5/8-inch (8mm) of cover adjustment. Do not install Model Fl FR Series Concealed Pendent sprinklers in ceilings which have positive pressure in the space above. Model Fl FR Series Concealed Pendent sprinklers require a 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The Model RC1 wrench is used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. Remove the protective cap to install the sprinkler, then reinstall the protective cap until the cover plate is installed. When inserting or remov- ing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. Do not wrench any other part of the sprinkler/cup assembly. Installation is com- pleted by removing the protective cap from the sprinkler and pushing the cover plate onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning the cover plate in the counter clockwise direction. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any concealed cover plate/cup assembly other than the Reliable Model CCP with Model Fl FR56 Concealed Pendent and Model Fl FR56LL Concealed Pendent sprinklers or the use of the Model CCP Concealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties, listings and approvals. 2. Technical Data: Sensitivity: Quick-response Thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar) - 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414 & RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Model Nominal K-factor Nominal Orifice Diameter Deflector/ Orientation Nominal Sprinkler Height _____ Installation Wrench SIN Listings and Approvals Approval Notes US Metric inches mm inches mm F1FR28 2.8 40 3/8 10 Pendent 2.25 57 DorW2 RA1411 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D or W2 RA1421 cULus 1,2 F1FR40 4.0 57 3/8 10 Pendent 2.25 57 DorW2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS F1FR42 4.2 60 7/16 10 Pendent 2.25 57 DorW2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 DorW2 IRA1423 cULus 1,2 F1FR42LL 4.2 60 7/16 10 Pendent 2.25 57 DorW2 RA1410 cULus, ULH __ Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1FRXLH (F1FR42 with Pintle) 4.2 60 7/16 10 Pendent 2.25 57 DorW2 RA1413 cULus 2 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 DorW2 RA14231 cULus 1,2 F1FR56 5.6 80 1/2 15 Pendent 2.25 57 DorW2 RA1414 cULus, FM, LPCB, VdS, EC 1,2,3,4 Recessed Pendent 2.25 57 GFR2 RA1414 cULus, FM, LPcB, VdS, EC 1,2,3,4 concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D or W2 RA1425 cULus , FM , LPCB, VdS, EC 1,2,3,4 "Conventional 2.25 57 (Pendent or Upright)" D or W2 RA1475 LPCB, VdS, Ec 4 F1FR56LL 5.6 80 1/2 15 Pendent 2.25 57 D or W2 RA1415 cULus, ULH 1 Recessed Pendent 2.25 1 57 GFR2 RA14151 cULus, ULH Concealed Pendent 2.25 57 RC1 RA1415 cULus, ULH 6 F1FR56 5.6 80 1/2 15 Horizontal Sidewall 2.63 67 D or W2 RA1435 cULus, FM 1,2,3,7 Recessed Horizontal 2.63 67 Sidewall GFR2 RA1435 cULus, FM 8 F1FR56 5.6 80 1/2 15 Vertical Sidewall (Pendent or Upright) 2.25 57 DorW2 RA1485 cULus, FM, LPCB 1,2,3,9 ( cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. 4) Available with LPCB and VdS approved Polyester coating. VdS and EC approvals of the Fl FR56 Concealed Pendent sprinkler are for 155°F (68°C) temperature rated sprinklers only. VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch (12.7mm) adjustment Model CCP cover plate only. Model F1 FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch (12.7mm) of adjustment or low profile with 5/16-inch (8.0 mm) of adjustment. 7) cULus Listing of the Fl FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. FM Approval of the Fl FR56 Hori- zontal Sidewall sprinkler is for Light Hazard occupancies only. cULus Listing and FM Approval of the Fl FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. The Fl FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies. Minimum to maximum deflector to ceil- ing distance shall be 4 inches to 12 inches (102mm to 305mm). LPCB approval of the El FR56 Vertical Sidewall sprinkler is for installation in the Pendent position Only. Listed and Approved Temperature Ratings Model Deflector/ Orientation Ordinary Temp. Classification 100°F (380C) Max. Ambient Temp. Intermediate Temp. Classification 150°F (650C) Max. Ambient Temp. High Temp. Classification 225°F (107°C) Max. Ambient Temp. 135°F (57°C) Temp. Rating I 155°F (68°C) Temp. Rating 175°F (79°C) Temp. Rating 200°F (93°C) Temp. Rating 286°F (141°C) Temp. Rating Orange Bulb I Red Bulb Yellow Bulb I Green Bulb Blue Bulb Pendent cULus F1FR28 Recessed Pendent cULus I -- ________ Upright cULus Pendent VdS F1FR40 Recessed Pendent VdS I -- Pendent cULus FIFR42 Recessed Pendent cULus -- _________ Upright cULus Pendent -- I cULus, ULH I -- I FIFR42LL Recessed Pendent -- I I cULus, ULH I -- Pendent cULus FIFRXLH Recessed Pendent cULus I -- _________ Upright cULus Pendent cULus, FM, LPCB, VdS, EC Recessed Pendent cULus, FM, LPCB, VdS, EC -- I Concealed Pendent* cULus I cULus,VdS,EC I cULus I -- FIFR56 Upright cULus, FM, LPCB, VdS, EC "Conventional (Pendent or Upright)" LPCB, VdS, EC Pendent -- I cULus, ULH I -- FIFR56LL Recessed Pendent -- cULus, ULH I -- _________ Concealed Pendent* -- I cULus, ULH I -- Horizontal Sidewall cULus, FM Fl FR56 _________ Recessed Horizontal Sidewall cULus, FM -- FIFR56 Vertical Sidewall (Pen- dent _or_Upright) cULus, FM, LPCB * Model Fl FR56 Concealed Pendent and Fl FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated cover plate. For Intermediate Temperature Classification sprinklers use a 165°F (74°C) temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Model Fl Model F2 Model FP Model Deflector/ (Fig. 1 & 3) (Fig. 1 & 3) (Fig. 2) SIN Orientation e 3/4-inch (19mm) 1/2-inch (12.7mm) 1/2-inch (12.7mm) adjustment adjustment adjustment FIFR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 F1FR42 Recessed Pendent cULus cULus cULus RA1413 F1FR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 F1FR42XLH Recessed Pendent cULus cULus cULus RA1413 FIFR56 Recessed Pendent cULus, LPCB, VdS, cULus, FM, LPCB, cULus, VdS, EC RA1414 EC VdS,EC FIFR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 FIFR56I Recessed Horizontal Sidewall cULus cULus, FM cULus RA1435 4. 2 1/4" HOLE DIA. [57.2mm] I 15/16" D[49.[41-2-1 IA r TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS I / I - Fl EScUTHEONj_ LJ 3/4719mm] ADJUSTMENT F2 ESCUTCHEON 1/2712.7mmj ADJUSTMENT Fl ESCUTCHEON 1/8" ,J T AT MAXIMUM RECESS = 7/8722.2mm] 13.2mm1 I / AT MINIMUM RECESS = 1-5/8741.3mm] F2 ESCUTCHEON I AT MAXIMUM RECESS 1-1/8728.6mm] AT MINIMUM RECESS = 1-5/8741.3mm7 1" X 1/2' REDUCER FACE OF FITTING TO FACE OF CEILING DIMENSION F? ESCUTCHEON AT MAXIMUM RECESS 1 "[25.4mm] AT MINIMUM RECESS = 3/879.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS 3/4719mm] 7-7-7-1-7-71 AT MINIMUM RECESS = 3/879.5mm] 2 27/32" 014. [72.2mm] Model Fl FR56, Fl FR56LL, Fl F1R42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl F1R28 Recessed Pendent sprinkler with Model Fl or F2 escutcheon 2 5/8" DIA. [66.7mm] - 1" X 1/2" REDUCER HOLE IN CEILING I 2 5/16" 0/A. [58.7mm] CUP CEILING FACE OF FITTING WSW TO FACE OF CEILING DIMENSION AT MAXIMUM RECESS 1-1/2738mm] AT MINIMUM RECESS = 1725.4mm] ' = AT MAXIMUM RECESS = 9/16114.3mm] 12[12.7mm.J AT MINIMUM RECESS = 1725.4mm] ADJUSTMENT 3 1/4" DIA. [82.6mm] Lei Model Fl FR56, Fl FR56LL, Fl FR42, Fl FR40, Fl FR42LL, Fl FRXLH & Fl FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION Fl ESCUTCHEON AT MAXIMUM RECESS = 1"[25.4mm] AT MINIMUM RECESS = 3/8"[9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 3/4"[19mm] AT MINIMUM RECESS = 3/8"[9.5mm] 2 1/4" HOLE DIA. [57.2mm] Fl ESCUTCHEON V.1 AT AJAVJAJIIAA I7CC - /"IA o....7 - ' AT MINIMUM RECESS = 2- 1/16"[52.4mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8"[41.3mm] U-118" AT MINIMUM RECESS 2- 1/16"[52.4mm] [3.2mm] " X 1/2" REDUCER I I 1 15/16" DIA.44 [49.2mm] 2 27/32" 0/A. [72.2mm] I (1) 4"-12" [10 1.6mm-304.8mm] CEILING TO DEFLECTOR TURN COLLAR UNTIL -' TIGHT AGAINST SPRINKLER WRENCH BOSS. Fl ESCUTCHEON j [ 3/4"[19mm] ADJUSTMENT E2 ESCUTCHEON 1/2"[12. 7mm] ADJUSTMENT c,,3r RECESSED HSW w/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" - 6" [10 1.6MM - 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig. 3 Model Fl FR56 Recessed Horizontal Sidewall sprinkler with Model Fl or F2 escutcheon 1" x 1/2" REDUCING TEE OR ELBOW 2 518 DI A. 2 5/16" 0/A - - HOLE IN CEILING CUP VU 1 1/2" MAX. / // 1 FACE OF FITTING / / / ,, / / TO FACE OF CEILING DIMENSION CEILING COVER ADJUSTMENT 15/16" COVER PLATE / ASSEMBLY / 3 5/16" DIA. SPRINKLER CONCEALED, 1/2" ADJUSTMENT O17FGO1A Fig. 4 Model Fl FR56/F1 F1R56LL Concealed Pendent sprinkler with standard depth 1/2-inch (12.7mm) adjustment - Model COP cover plate I" x 1/2" REDUCING TEE OR ELBOW —EIf- - 2 5/8" 0/A. 2 5/16 0/A - _____ HOLE IN CEILING CUP 03 V8 1 1/2k' MAX. p 7/77 FACE OF FITTING TO FACE OF CEILING DIMENSION _i_ CEILING 3/4 COVER ADJUSTMENT / " COVER PLATE— / ASSEMBLY 3 5/16 0/A. SPRINKLER CONCEALED,5/16"ADJUSTMENT 017F6024 Fig. 5- Model Fl FR56/F1 FR56LL Concealed Pendent sprinkler with low profile 5/16-inch (8.0mm) adjustment - Model COP cover plate Maintenance The Model Fl FR Series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Finishes (1) StandardFinishes Sprinkler Escutcheon I Cover plate111 Bronze Brass Chrome ChromePlated Chrome White Polyester Plated Coated (4K,5)(6) WhitePainted Special Application Finishes Sprinkler Escutcheon Cover plate111 Electroless Nickel PTFE71 Electroless Nickel PTFE Bright Brass BrightBrass'3 Bright Brass BlackPlating BlackPlated Black Plated Black Paint Black Paint 216 BlackPaint Off White Off White126 Off White Satin Chrome Chrome Dull ChromeDull — Other finishes and colors are available on special order. Consult the factory for details. Custom color painted sprinklers may not retain their UL Corrosion resistance listing. Coverplate custom paint is semi-gloss, unless specified otherwise. cULus Listed only. 200°F (93°C) maximum. cULus listed "corrosion resistance" applies to SIN Numbers RA1435 (HSW), RA1485(VSW), RA1425 (Upright), RA1414 (Pendent) and RA1415 (Pendent) in standard black or white. Corrosion resistance in other polyester colors is available upon request. FM Approvals finish as "Polyester coated" applies to SIN Number RA1414, RA1435 and RA1425 in standard black or white. (8) LPCB and VdS Approved finish applies only to RA1425, RA1414, RA1418 (VdS) and RA1475. cULus listed Corrosion Resistant MaterialData Frame: DZRBrass,QMBrass,orLowLeadBrass Deflector CDA Alloy220,260,or510 Load Screw\Pintle: CDA Alloy 360 or 544 Cup: CDA Alloy 651or 693 Washer Nickel Alloy 440 or 360, coated with PTFE AdhesiveTape Bulb: Glass Ordering Information Specify: Sprinkler Model: [Fl FR28] [Fl FR40] [Fl FR42] [Fl FR42LL][171 FRXLH][F1 FR56][F1 FR56LL] Sprinkler Deflector/Orientation: [Pendent] [Recessed Pendent) [Upright][Conventional][Horizontal Sidewall] [Recessed Horizontal Sidewall] [Vertical Sidewall] Sprinkler threads: [1/2-inch NPT][ISO 7-R1/2] Sprinkler Temperature Rating: [135°F (570C)][155°F (68°C)] [175°F (79°C)][200°F (93°C)] [286°F (141°C)] Sprinkler Finish Escutcheon Model: [F1][F2][FP] Escutcheon Finish (where applicable) Cover plate Model: [standard profile COP 1/2-inch (12.7mm) adjustment][low profile COP 5/16-inch (8.0mm) adjustment] Cover plate Temperature Rating: [135°F (57°C) for use with Ordinary Temperature sprinklers][165°F (74°C) for use with Intermediate Temperature sprinklers] Cover plate Finish Note: When Model F1FR Series Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately. 7. Reliable ... For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. Automatic sprinklers Flush automatic sprinklers Recessed automatic sprinklers Concealed automatic sprinklers Adjustable automatic sprinklers Dry automatic sprinklers Intermediate level sprinklers Open sprinklers Spray nozzles Alarm valves Retarding chambers Dry pipe valves Accelerators for dry pipe valves Mechanical sprinkler alarms Electrical sprinkler alarm switches Water flow detectors Deluge valves Detector check valves Check valves Electrical system Sprinkler emergency cabinets Sprinkler wrenches Sprinkler escutcheons and guards Inspectors test connections Sight drains Ball drips and drum drips Control valve seals Air maintenance devices Air compressors Pressure gauges Identification signs Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address 0 Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 03 /17 P/N 9999970300 800-381-9312 Technical Services +1-401 -781-8220 www.tyco-fire.com GRINNELL G-FIRE Figure 40-5 Strap (Pipe Outlet) General Description The Figure 40-5 Strap is an economi- cal alternative to welded pipe outlets on steel pipe. The Figure 40-5 Strap can be used with full lengths of pipe and eliminates threading and welding, decreasing waste and Installation time. The Figure 40-5 Strap can be used in wet, dry pipe, and deluge systems. The Figure 40-5 Strap described here- in must be installed and maintained in compliance with this document, and with the applicable standards of the National Fire Protection Association, in addition to the standards of any au- thorities having jurisdiction. Failure to do so may impair the performance of this device. Owners are responsible for maintaining their fire protection system and devices in proper operating condition. The in- stalling contractor or sprinkler manu- facturer should be contacted with any questions. Technical Data Approvals UL, FM, ULC, and VdS Refer to the Fire Protection Submittal Sheet TFP1 800 for exact listing and approval information. Maximum Working Pressure 1.75 psi (12,1 bar Housing Ductile iron conforming to ASTM A536, Grade 65-45-12 Protective Coatings Clear rust inhibitive coating Bolts/Nuts ANSI The U-bolt is made from carbon steel conforming to ASTM A 307 Grade A and zinc-electroplated con- forming to ASTM B 633. The flange nuts are made from car- bon steel conforming to ASTM A 563 Grade A, and zinc elecfroplated per ASTM B 633. Metric The gold colored carbon steel U- bolt conforms to ASTM F68 Class 4.8 and zinc electroplated per ASTM B 633. The gold colored flange nuts are carbon steel conforming to ASTM A-563M Class. 9. and zinc electro— plated per ASTM B 633. Stainless Steel U-Bolts and Nuts are available upon request. Gasket Grade E" EPDM Green color code Refer to data sheet TFP1895 for ad- ditional gasket information. Page 1 of 4 SEPTEMBER 2011 TFPI720 4 EP F~~ DN"S ~ DUCTILE IRON THREADED FITTINGS •'VANVIL FIG. 3221R Reducing Coupling USIEO APPROVED Eor n5s/Aeval DeIas e5d1a5ers, visit our Website atW&WATNAirdwaier corSad an Mvgo Sues RBI)resentatr.e. FIGURE 14I : 4:DUCING UPLING Nominal Size Maximum Woriing eeA Dimension A Approx. Wt. Each .In. Imo PSI (kt°o) In. (mm) Lbs. (kg) 1 x ½ 500 1.69 0.39 75.•_, 500 _ 1x'4 1.69 0.53 / / A — Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/1iLC, and FM pressure mtings versus pipe schedule, please V= .corn or contact your bed Anvil Representative. Dimensions: ASME B 16.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME B 1.20.1 Agency Approvals: All ductile iron threaded fittings are UL/UI.0 Listed and FM Approved. NOTICE: Ductile iron fittings hove higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATiON APPROVAL STAMP Project: fl Approved Address: Approved as noted Contractor: 0 Not approved Engineer; Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1.1 5 c® LISTED APPROVED For LigsFuppmvaI Details and Lmua5ons, 'd55G.0Vebt5 otw oraa5cOcn CT contact an Anvt° Sales Repmsenta5ve. :6:~~~ DUCTILE IRON THREADED FITTINGS WANVIL FIGn 3221 Coupling £10 rFIGURE 1cfJ.4 .I1uJ:JII"e Nominal Size Working :s'.treA Dimension A Approx. WI. Each .hc (MW . t(kPa3 h7.(nnn) Lbs.(kg) 1 500 1.61 0.40 1¼ 500 1.93 0.51 1½ 500 2.15 0.15 2 500 7.5 1.15 I / A - Working Pressure Ratings are For reference only and based on Sco. 40 pipe. For the latest Ul./ULC, and FM pressure ratings versus pipe schedule, please visit anvintl.com or contact your local Anvil Representative. Dimensions: ASME Bi 6.3 Material: ASTM A536 Grade 65-45-12 Finish: Black Threads: NPT per ASME 81 .20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron fittings should be tightened approximately three turns beyond hand tight, but no more than (our turns. PROJECT INFORMATION APPROVAL STAMP Project: Approved Address: U Approved as noted Contractor: []Not approved Engineer-,Remarks: Submittal Date: Notes 1: Notes 2: I SPF/01-1 .15 US5D APPROVED For Us g/Aproval Delas asd tJrnta14ons, 4sIew we5s5e at wawanvestl.cem c contact an Anv1' Sales Renresestatse. DUCTILE IRON THREADED FITTINGS v4NV1I FIG. 3201 9O Elbow [FIGURE 3201 :j.YY I Nominal Size Maximum Working Pressure I Dimension A Approx. Wt. Each hi. fmm) PSi (kPa) in. mm) lbs. (kg) 1 500 1.50 0.62 1¼ 500 1.75 0.90 1112 500 1.94 1.20 2 500 2:25 - 185- A - Working Pressure Ratings are for reference only and based on Sds. 40 pipe. For the latest UL/UIC, and FM pressure ratings versus pipe schedule, please visit onvilintl.com or contact your local Anvil Representative. Dimensions: ASME Bi 6.3 Material- ASTMA536 Grade 65-45-12 Finish: Block Threads: NPT per ASME 81.20.1 Agency Approvals: All ductile iron threaded fittings are UL/ULC Listed and FM Approved. NOTICE: Ductile iron Fittings have higher tensile strength than that of steel pipe. Therefore, over tightening can cause damage to pipe threads which may cause leakage. Ductile iron Fittings should be tightened approximately three turns beyond hand tight, but no more than four turns. PROJECT INFORMATION L11II!Iii53fb'lI Project: El Approved Address: D Approved as noted Contractor: 0 Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: SPF/Dl-1 .15 4.3.8.2 Material Sp e c i f i c a t i o n s HDl/HDI-L, 1/4", 3/8, 1/2", a n d H D I 5/8" and 3/4" are manufactured f r o m m i l d carbon steel which is plate d w i t h a z i n c f i n i s h f o r c o r r o s i o n p r o t e c t i o n i n accordance with ASTM 8 6 3 3 , S C 1 , T y p e I I I HDI Stainless Steel material m e e t s t h e r e q u i r e m e n t s o f A I S I 3 0 3 4.3.8.3 Technical D a t a Table I - HDI/HDI-L Specification Table 1/4 318 112 5/8 3/4 Size in, Details (mm) (6.4) (9.5) (12.7) (15.9) (19.1) dw Nominal Bit diameter - in. 3/8 1/2 5/8. 27/fl 1 h. Std. depth otembea. in. 1 1-9/16 2 2-9/16 3-3/16 Anchor legtti (mm) t25 (40) (51) (65) (81) h1 Hole de pth (,, Useable thread in, 7/16 5/8 11/16 7/8 1-3/8 length (mm) (11) (15) (17) (22) (34) Threads per inch 20 16 13 ii 10 Ii min. base material in. 3 3-1/8 4 5-1/8 6-3/8 Utickress mm (16) (19) (102) (130) (162) T, max, tigiflenng ft-lb 4 - 11 22 37 80 torque (Nm (5.4) 1 (14.9) (29.8) (50.2) (108.5) .1 Systerns 4.3.8 HDI & HDI-L D r o p - I n A n c h o r 4.3.8.1 Product Description 4.3.8.2 Material Specifications 4.3.8.3 Technical Data 4.3.8.4 Installation Instructions 4.3.8.5 Ordering Informatio n Product Features HDI Anchor, setting toot and H i l t i d r i l l b i t form a matched tolerance s y s t e m to provide reliable fastening s Allows shallow embedme n t w i t h o u t sacrificing performance Lip provides flush installa t i o n , consistent anchor depth, a n d e a s y rod alignment (HDI-L) Lip allows accurate flush surface setting, independ e n t of hole depth (HD!-L) Ideal for repetitive fastenin g s w i t h threaded rods of equal len g t h Guide Specifications Expansion Anchor Expansion anchors shall be flush or shell type a n d z i n c plated in accordance with A S T M B 6 3 3 , SC 1, Type III. Anchors shali b e - H i l d HDI/HDl-L anchors as supplied by Hilti. Installation Install shell or flush type anchors in holes drilled w i t h H i l t i c a r b i d e tipped drill bits. Install ancho r s a s p e r manufacturer's recommend a t i o n s . 4.3.8.1 Product Des c r i p t i o n The Hilti HDVHDI-L Drop-In anchor i s a n • Intelligent expansion se c t i o n internally threaded, flush m o u n t e d adapts to the base material a n d expansion anchor for use in c o n c r e t e . reduces number of hamm e r b l o w s up to 50% (HDl=L) Listlnas/ADorovals City of Los Angeles Research Report No. 237J DL OnlyL FM (Factory Mutu$) Pipe Hanger Components f o r A u t o m a t i c Sprinkler Systems (3/8" -3/ 4 " ) (HDI and HDI-L) UL 203 Pipe Hanger Equi p m e n t f o r F i r e Protection SeceJ3/83/4 ) ARNI2" C. Combined Shear and Te n s i o n Loading IN \' / V\5'3 s (- J + ) 1.0 (Ref. Section 4.1.9.6) \ ed ' redl Fig. 69- Beam Clamp Retaining Strap Component of State of California OSHPD Approved C®US LISTED Seismic Restraints System Size Range - 3/8" thru 7/8° rod by 4° thru 16" length.* Material - Pre-Galvanized Steel Function - To offer more secure fastening of various types of beam clamps to beam where danger of movement might be expected. NFPA 13 requires the use of retaining straps with all beam clamps installed in earthquake areas. Satisfies requirements of NFPA 13 (2010) 9.3.7.1. Important Note - Good installation practice of a retaining strap requires that the strap be held tightly and securely to all component parts of the assembly. Therefore a locking, mech- anism of some kind such as a hex nut or the beveled locking slot on the TOLCO® Fig. 69R will provide a more secure reliable installation. Approvals - Underwriters' Laboratories listed in the USA (UL) and Canada (cUL). Approved for use with any listed beam clamp. Included in our Seismic Restraints Catalog anproved by the State of California Office- o1 Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relat- ing to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Pre-Galvanized Order By - Figure number, type, length "B" and rod size being used with beam clamp Note - Minimum return on Strap: 1'. Dimensions Type Rod Size A Hole Size B 1 3/8 7/16 Specify 1/2 9/16 Specify 2 5/8 11/16 Specify 3/4 13/16 Specify 3- 3/8 - 7/8 Specify Specify * Longer lengths are available, consult factory. OFFICEIMAPJIJFACTURIHG FACILITY • 1315 SAMPSON AVE. • CORONA. CA 92879 .PEI: 951.737.5599 • FAX: 951.737.0330 CUSTOMER SERVICE • 800.785.5266 www.tolco.com Fig. 65 and Fig. 66 Reversible C-Type Beam Clamps 3/4" and 11/4" Throat Openings Size Range - (Fig. 65 and Fig. 66) 3/8", 1/2" and 5/8" rod Component of State of California OSHPD Approved c Ut us USTEI) Material - Carbon Steel with hardened cup point set screw and Seismic Restraints System jam nut Function - Recommended for hanging from steel beam where flange thickness does not exceed 3/4" (Fig. 65) or 11/4° (Fig. 66). Features - All steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or B bottom flange of the beam. (Beveled lip allows hanging from top 1 flange where clearance is limited.) May be installed with the set 0 screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the E. clamp. Open design permits inspection of thread engagement. , ,,. - C Approvals - Underwriters' Laboratories Listed in the USA (UL) and Canada (cUL). Exceeds requirements of the National Fire Protection Association (NFPA), Pamphlet 13, 3/8" rod will support 1/2° thru 4° - pipe, 1/20 rod will support 1/2" thru 8 pipe. Included in our Seismic -rr Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPDI. For additional '--- A load, spacing and placement relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Finish - Plain Note - Available In Electro-Galvanized and HOG finish. Order By - Figure number, rod size and finish Fig. 65 Patent #4,570,885 Fig. 65 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs.* WtJ100 3/8 13/1e 3/4 1 7/16 1 610 28 1/2 1½ 3/4 1 9/16 11/4 1130 55 5/8 11h 3/4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. Fig. 66 Dimensions • Weights Rod Size Max. Rec. Approx. A B C D E F Load Lbs* Wt./100 3/8 1¼6 11/4 1 7/16 1 610 28 1/2 1½ 1114 1 9/16 1114 1130 55 5/8 1½ it!4 1 9/16 11/4 1130 55 * Max. loads for clamp with set screw in up or down position. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92819 • PH: 951.7375599 • FAX 951.737.0330 CUSTOMER SERVICE • 8011.786.5266 www.toko.com C®US LISTED Fig, 25 - Surge Restrainer Size Range - One size fits 3/411 thru 2" pipe. Material - Pre-Galvanized Steel Function - Designed to be used in conjunction with TOLCO® Band Hangers to eetrict The upward movement ot piping as it occurs during sprinkler head activation or earthquake type activity. The surge restrainer is easily and effici e n t - ly installed by snapping into a locking position on the band hanger. Thi s p r o d u c t is intended to satisfy the requirements as indicated in the National Fire P r o t e c t i o n Association NFPA 13, 2010 edition, 9.2.3.4.4.1 and 9.2.3.4.4.4 Can be u s e d t o restrain either steel pipe or CPVC plastic Pipe. Approvals - Underwriters' Laboratories Listed Qft when used with TOLCO band hangers Fig. 2, 2NFPA and 200, in the USA (UL) and Canada (clJL). Finish - Pre-Galvanized Order By - Figure number and TOLCO band hanger, size from 3/4" thru 2". Patent #5,344,108 OFFICE,MANUFACTURING FACILITY • 1375 SAMPSON AVE • CORONA. CA 92879 • PH: 951.7315599 • FAX: 951.737.0330 CUSTOMER SERVICE 9 800.789.5266 FIG.. 69:_ LOADS WEIGHT_(LBS)_• DIMENSIONS (IN) _(LBS)_o Pipe Size Max Load Weight A Rod Size B C F G Width ½ 300 0.10 ½ 2/8 2 19A6 J8 34 0.10 2% 1% 15/16 1 0.10 2%s 111/16 1 114 0.10 2% ½ i/ 1% 0.10 2% 2 0.11 31/4 2½ 11/8 214 525 0.20 4 2% 1/16 3/4 2% 3 0.20 3'3/1 r, 2'3' 6 13A6 4 650 0.30 41145 31/ 19/16 43/i 5 1,000 0.54 1/2 5A6 6 0.65. gil/Is 5/ts 1.00 8 7 211/is Note: Reflects changes In rod diameter from previously published data per recent revisions in MSS-SP-58 & 89 1/20 through 1" pipe -0-: o-A i'/' through 28' pipe PIPE RINGS W ANVIL Fige 69 Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range: 1/2' through 8" Material: Carbon steel Finish: Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated. Service: Recommended for suspension of noninsu1ated stationary pipe tine; Maximum Temperature: 650' F Approvals: Complies with Federal Specification A-A-1192A (Type 10). WW-H-171-E (Type 10), ANSI/MSS SP-69 and MSS SP-58 (Type 10). UL Listed and FM Approved (Sizes 3/40 8"). Features: Threads are countersunk so that they cannot become burred or damaged. Knurled swivel nut provides vertical- adjustment after piping is in place. Captured swivel nut in the /2" through 6" sizes. The capture is permanent in the bottom portion of the band, allowing the hanger to be opened during installation if des i r e d , b u t not allowing the nut to fall completely out. Ordering: Specify size, figure number and name. Note: The acceptability of galvanized coatings at temperatures above 450'F is at the dis c r e t i o n of the end user. Metric nut available upon request. Non-captured nut also available upon request. ®us U3110 APPHOVEO PROJECT INFORMATION APPROVAL STAMP Project: nApproved Address: Approved as noted Contractor: LI Not approved Engineer: Remarks: Submittal Date: Notes 1: I Notes 2: P11-1.15 ruse 1 C Home 11 Up 55 Wood ] [ £5 Ste& J [ Sheetrock Hurricane Tool [ _Pole [Sammy Assortment l I Ceiling Screws 1 SammySaddle [Sammy SwivelHe] L_Dektte 11_Install SWG - Wood SW Kt GST-Wood Sammy ] I F_ - OST - Steel samrnvj SWDP Sleet SW ST-ConcreteSamm FWC - ConcreteSW All-thread Rod Anchoring S y s t e m s Wood Sidewinder -Self drilling & self-tappin g i n t o wood WOOD' 1 /4" Rod • Horizontal Mount Use #I4SW Nut Driver (I t e m # 1 0 1 ) - Rod Shank shank It Part Box Model Size Diameter Length Qty LO inches inches inches ____ - #14SW 40168018957SWG 100 1 / 4 - 2 0 1/4 1 125 Item #101 300 8019957 SWO 200 1 / 4 - 2 0 1/4 2 125 PN 8114910 WOOD , 318" Rod • Horizontal Mount Use #14SW Nut Driver ( I t e m # 1 0 1 ) UL Test littp:Hsammysuperscrew.c o m / S W C ; . h t m 2/20/2009 c~~c~)~?D ARCQ SINcE 1081 ARGCO BR29 Braided Flexible Fire Sprinkler Drop 'Larger inner diameter for better flows -Save Time & Money -No cutting, no welding, no threading 'Perfect for retrofit applications 'Easy to move for layout changes c®uS <<@~>a LISTED APPROVED UL Listed FM Approved ARGCO Flexible Sprinkler Hose is designed to be used in wet sprinkler systems between the branchline and sprinkler when installed in accordance with NFPA 13,13D, and-13R. Stainless steel braiding over the outside of the tube provides additional mechanical protection to the drops and is required to resist system pressurisation. ARGCO's 2913-provides a unique sprinkler drop assembly comprised of the following components: 304 Stainless Steel Flexible Hose with Two Slip Nuts Branch line Inlet Nipple NPT (BSPT available) Straight Outlet Sprinkler Reducer (90 degree reducer available) NPT (BSPT available) Center Bracket, End Brackets, and Square Support Bar TECHNICAL DATA *UL Listed FM Approved 'Rated Pressure: 175 PSI (12.5 Bars) -Max. Service Pressure: 200 PSI (14 Bars) -Maximum Ambient Temperature: 225°F (107°C) 'Maximum Sprinkler K-factor for ½" outlet: 8.5 ENO -Maximum Sprinkler K-f actor for 3/4" outlet: 14.0 'Designed for use in wet systems 'Flexibility Type: Unlimited Hose Diameter: 28.2 mm I.D, 28.8 mm O.D. 'Minimum Bend Radius: 6" UL, 9" FM SPRINKLER HEAD (not Included) Anchoring components are intended for use with drop ceilings conforming to ASTM C635 and other major standards when installed in accordance with the standard practice for installation of metal ceiling suspension systems for acoustical tile and lay-in panel, ASTMC C635 or other equivalent standards. I phone8DtJ-854--1 Di 5 argco.com tax800-924-5922 I 7/12/2017 AR CO snacE 2082 DH Braided Flexible Fire Sprinkler Drop Friction Loss Data and Specifications BRAIDED 1/2" NPT 3/4" NPT Equivalent Length of Equivalent Length of Maximum # of 1:@US 1 ft Sch 40 Pipe 1 ft Sch 40 Pipe 900 Bends I UL FM UL I FM UL FM Lnnth ITEM I i itArI AnnrnvI ITEM it Listed I Annroval Listed AnnrnvI AR-J3 FLEX-07 28" (0.6m) 6530165 6 f 23.0 ft 6530175 lift 16.1 ft 1 1 AR-B FLEX-b 39" (0.9 m) 6530166 14 ft 33.5 ft 6530176 16 ft 27.4 ft 1 2 AR-B FLEX-12 48" (1.2 m) 6530167 22 ft 40.5 ft 6530177 30 ft 35.0 ft 2 2 AR-B FLEX-15 60" (1.5 m) 6530168 29 ft 44.9 ft 6530178 38 ft 39.3 ft 2 3 AR-B FLEX-18 72"(1.8m) 6530169 34 ft 49.3 ft 6530179 40 ft 43.7 ft 2 4 Bend Characteristics One Bend Two Bends Three Bends L - Minimum I bend radius L1L 2X Minimum bend radius OR Minimum end radius OR Minin bend nimum A radius Minimum ( bend radius Minimum bend radius Minimum - bend radius I phone800-854-1 015 •argco.corn fax800-924-5922 7/12/2017 t7- kt~:-J% LE3 AR CO BR29 Braided Flexible Fire Sprinkler Drop C (9) us LISTED <<@~ 1>3 APPROVED 28.8 mm INNER DIAMETER 304 STAINLESS STEEL HOSE FOR BETTER FLOW CHARACTERISTICS. 110 mm 1"xl/2orl"x3/4"OUTLETNIPPLE HINGED CENTER BRACKET FOR QUICK AND EASY INSTALLATION 58 or 98 mm END BRACKETS FOR DEEP AND SHALLOW INSTALLATIONS. TIGHTENS WITH PHILLIPS HEAD SCREW DRIVER. 900 ELBOWS AVAILABLE 1/2": Item #6530190S 3/4": Item #6530192S ARGCO'S B29 Flexible Sprinkler Hose Assemblies are designed to be used in wet sprinker stystems between branchline and sprinkler when installed in accordance with NFPA 13, 13D and 13R. User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of ARGCO products for a particular end-use application, in accor- dance with industry standards and project specifications, and the applicable building codes and related regulations as well as ARGCO performance, maintenance, safety, and warning instructions. Nethingn-Ihis or any other document, nor anyverbalrecomrnendation, advice, or opinion-from any ARGCO employee, shall be deemed to alter, vary, supersede, or waive any provision of ARGCO's standard conditions of sale, installation guide, or this disclaimer. ARGCO reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Warranty Refer to-the Warranty section or contact ARGCO for details. I phoneBOO-854-1 015 argco.com fax800-924-5922 I 7/12/2017