Loading...
HomeMy WebLinkAbout2870 WHIPTAIL LP; BLDG A; AS160126; Permit9/10/2020 AS160126 Permit Data City of Carlsbad Sprinkler Permit Permit No: AS160126 Job Address: 2870 WHIPTAIL LP Permit Type: SPRINK Parcel No: Lot #: 0 Reference No.: Status: ISSUED Applied 5/10/2016 Approved: 6/22/2016 Issued: 6/22/2016 PC #: Inspector: Project Title: SR CARLSBAD OAKS BLDG A COMM: ADD FIRE SPRINKERS FOR NEW SHELL BLDG. START POINT IS 6" ABOVE FINISHED FLOOR Applicant: Owner: EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WY SAN MARCOS, CA 760-310-6122 Fees ($) Add'I Fees ($) Total ($) Balance ($) 618 0 618 0 1/1 CARLSBAD FIRE DEPARTMENT Fire Prevention Division 1635 Faraday Avenue - Carlsbad, CA 92008 760.602.4665 WATER AVAILABILITY FORM SECTION A: TO BE COMPLETED BY CUSTOMER PROJECT NAME: 2864 Whiptail Loop SR#: (Assigned upon plan submittal) PROJECT ADDRESS: 2864 Whiptail Loop CITY: Carlsbad PHONE: ( 760 ) 310.6122 (Epic Fire Protection, Inc.) FAX NUMBER: (760) 798.0556 Largest Building (ft.2): Sprinkled ? Construction Type: SECTION B: TO BE COMPLETED BY LOCAL WATER COMPANY. CUSTOMER TO PROVIDE RESULTS TO CFD. Water Purveyor: City of Carlsbad Location of test (reference map required): Whiptail Loop north of Caribou Ct, TEST INFORMATION IS VALID FOR 6 MONTHS FROM DATE PERFORMED Flow Test Results Static pressure: 163 PSI Hydrant Number (if applicable):H61668 Elevation of test: 324 Feet Date/Time of Test': Pitot Tube Reading: PSI Corresponding Flow: GPM Total Flow: 8,000 GPM Residual Pressure 136 PSI Atpeakdemand, this water system is capable of providing a fire flow discharge @ 20 psi of greater than 8,000 GPM. Test to be performed as close as possible to the time the most conservative flows and pressures are expected. Note: If the water availability information was obtained in a manner other than a flowtest (i.e. computer modeling), fill out the information above as applicable and check here: x Name: Jennifer R.Mael,P.E, Eng. Lic. No. (if applicable): C69606 ( Signature: Title/OrgIPi6iectManager Date: 02/18/2016 2864 Whiptail Loop Fire Flow Analysis Prepared By: Jennifer ft Maei, PE - MCS Date: Thursday, February 18, 2016 *0 100 a- 250 200 150 50 0 0250 500 Remote Area 1 - Supply / uemana iirapn 144.90 psi available at Sprinkler Demand of 138.13 psi - with System Flow of 1,961.7 GPM I_Margin: +4.7% 00 N1.85 750 1000 1250 1500 1750 2000 Water Flow (GPM) 2250 p. B88'OO Dashboard Hydraulics Hydraulics Summary Sheet Project Information Calculation Date: 5/5/2016 9:15:49 AM SR CARLSBAD OAKS BLDG A system ID drawing ref SYSTEM #1 building 2870 WHIPTAIL LOOP construction CARLSBAD CA occupancy contract # authority rgir4.r.4rtr Tvfrrr,iIi,uj EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email EPICFIRE@COX.NET r Sprinklers in Remote No. Mfgr Mod SIN# Size K 1.i12 1 VIKING K17 VK 116.8 Hydraulics Criteria - density ESFR GPM/ft2 system type WET design std NFPA 13 remote area 12 @ 52 PSI hazard EXTRA spr coverage RO 112 sprs flowing 12 figure calc'd volume 11,141.0 gal curve Itw Thef static pressure 146.70 psi residual pressure 122.40 psi quantity flowing 8,000.0 GPM elevation from if 0.00 ft date & time of flow test 2-18-16 location of flow test SITE © Copyright 2013 Sigma Development Group, Inc. Page 1 of 9 oo DaghL'oard Hydraulics Supply Analysis SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) Sprinkler Flow: 1461.7 GPM Additional Flows: 500.0 GPM Hose Flow at Zero: None Total System Flow: 1,961.7 GPM Maximum velocity in pipe 9- 10 is 32.1 ft/sec Nodes Analysis Node Elev Device ft KFactor Minimum Flow GPM Node Actual Pressure Discharge Notes psi GPM 109 37.3 Sprinkler 16.80 121.15 52.00 121.15 110 37.3 Sprinkler 16.80 121.15 52.01 121.15 108 37.3 Sprinkler 16.80 121.15 52.31 121.51 111 37.3 Sprinkler 16.80 121.15 52.43 121.64 101 37.3 Sprinkler 16.80 121.15 52.46 121.68 102 37.3 Sprinkler 16.80 121.15 52.46 121.68 105 37.3 Sprinkler 16.80 121.15 52.68 121.94 106 37.3 Sprinkler 16.80 121.15 52.69 121.95 100 37.3 Sprinkler 16.80 121.15 52.77 122.03 103 37.3 Sprinkler 16.80 121.15 52.89 122.18 104 37.3 Sprinkler 16.80 121.15 52.97 122.27 107 37.3 Sprinkler 16.80 121.15 53.14 122.47 2 0.0 Hose Flow 135.14 500.0 © Copyright 2013 Sigma Development Group, Inc. Page 2 of 9 d8800' Dashboard Hydraulics Pipe Information SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) From Elevi Pipe ID Flows Inside Length ft 1 C Value [Total I (Pt) psi Fitting ft I Elev (Pc) psi ft Added GPM Diameter Fittings I I Notes Elev2 Type in Friction Loss I To ft Total Total ft psi/ft Frict (Pf) psi 110 37.33 2/" Dyna Flow 2.7030 Len 10,0 Ftg 0.0 C = 120 Pt 109) 52.004 Pe 0,000 Pf 0.004 109 37.33 BL 10.3 0.00038 Total 10.0 111 37.33 2%" Dyna Flow 121.2 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 110) 52.008 Pe 0.000 Pf 0.422 110 37.33 BL 131.4 0.04219 81 37.33 TA" Dyna Flow 121.6 2.7030 T Len 106.8 Ftg 18.7 C= 120 Pt 111) 52.430 Pe 0.000 Pf 17.779 111 37.33 BL 253.1 0.14178 41 36.50 2'/2" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 = 120 Pt 81) 70.209 Pe 0.359 Pf 2.762 81 37.33 RN 253.1 0.14178 Total 19.5 40 36.50 4° Dyna Flow 4.3100 0 Len 0 10. Ftg 0.0 C = 120 Pt 41) 73.330 Pe 0.000 Pf 0.146 41 36.50 CM2 253.1 0.01461 Total 10.0 Total Pressure at Node 40) 73.476 psi 108 37.33 21/2' Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 I I Pt 109) 52.004 Pe 0.000 Pf 0.308 109 37.33 BL 110.9 0.03079 Total 10.0 61 37.33 21/2 ' Dyna Flow 121.5 2.7030 T Len 159.3 Ftg 18.7 C = 120 Pt 108) 52.312 Pe 0.000 Pf 21.538 108 37.33 BL 232.4 0.12107 Total 177.9 21 36.50 21/2 ' Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 61) 73.849 Pe 0.359 Pf 2.358 61 37.33 RN 232.4 0.12107 Total 19.5 20 36.50 4' Dyna Flow 4.3100 0 Len 10.0 I Ftg 0.0 C=120 Pt 21) 76.568 Pe 0.000 Pf 0:125 21 36.50 CMI 232.4 0.01248 hTotal 10.0 Total i'ressure at Nooe LU) 1O.OL PSI 106 37.33 2/° Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 105) 52.684 Pe 0.000 Pf 0.007 105 37.33 BL 14.7 0.00073 Total 10.0 107 37.33 21/2" Dyna Flow 121.9 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 106) 52.691 Pe 0.000 Pf 0.453 106 37.33 BL 136.6 0.0 4532 Total 10.0 © Copyright 2013 Sigma Development Group, Inc. Page 3 of 9 81OO Dashboard Hydraulics Pipe Information SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) From Elevi ft Pipe ID Flows Added Inside Length ft I C Value J Total (Pt) psi GPM Diameter in Fittings Fitting ft I I Elev (Pe) psi I Notes To ft Elev2 Type Friction Loss psi/ft Total Total ft] Frict (Pf) psi 80 37.33 2%" Dyna Flow 122.5 2.7030 1 Len 96.8 Ftg 18.7 c = 120 Pt 107) 53.145 Pe 0.000 P1 17,087 107 37.33 BL 259.1 0.14807 Total 115.4 40 36.50 2h/2 Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 Pt 80) 70.232 Pe 0.359 P1 2.885 80 37.33 RN 259.1 0.14807 To tal 19.5 39 36.50 4" Dyna Flow 253,1 4.3100 0 Len 10.0 Ftg 0.0 c = 120 Pt 40) 73.476 Fe 0.000 pf 0.538 40 36.50 CM2 512.2 . 0.05385 Total 10.0 - Total Pressure at Node 39) 74.015 psi 104 37.33 2'/" Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 105) 52.684 Fe 0.000 P1 0.290 105 37.33 BL 107.3 0.02897 Total 10.0 60 37.33 2'/2" Dyna Flow 122.3 2.7030 1 Len 3 159. Ftg 18.7 C = 120 Pt 104) 52.974 Pe 0.000 pf 21.054 104 37.33 BL 229.5 0.11834 20 36.50 21/,' Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C=120 Pt 60) 74.027 Pe 0.359 Pt 2.305 60 37.33 RN 229.5 0.11834 Total 19.5 19 36.50 4" Dyna Flow 232.4 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 20) 76.693 Pe 0.000 P1 0.445 20 36.50 CMI 461.9 0.04448 Total 10.0 Total Pressure at Node 19) 77.138 psi 102 37.33 21/2" Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C=120 Pt 101) 52.457 Pe 0.000 pf 0.004 101 37.33 BL 10.7 0.00041 Total 10.0 103 37.33 2'/" Dyna Flow 121.7 2.7030 Len 10.0 Ftg 0.0 C=120 Pt 102) 52.461 Pe 0.000 pf 0.428 102 37.33 BL 132.4 0.04277 Total 10.0 79 37.33 2/" Dyna Flow 122.2 2.7030 T Len 106.8 Ftg 18.7 C=120 Pt 103) 52.889 Pe 0.000 Pt 17.974 103 37.33 BL 254.6 0.14333 Total 125.4 39 36.50 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 79) 70.863 Pe 0.359 P1 2.792 79 37.33 RN 254.6 0.14333 Total 19.5 © Copyright 2013 Sigma Development Group, Inc. Page 4 of 9 DashPb r00 Pipe Information widHydrauflcs SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) From Elevi Pipe ID Flows Inside Length ft I C Value I [Total (Pt) psi Fitting ft I Elev (Pe) psi ft Added GPM Diameter Fittings Notes Elev2 Type in IFriction Loss To ft Total Total ft psi/ft Frict (Pf) psi 38 36.50 4" Dyna Flow 512.2 4.3100 0 Len io.ol Ftg 0.0 c = 120 Pt 39) 74.015 Pe 0.000 Pt 1.136 39 36.50 CM2 766.8 0.11360 Totario.o Total Pressure at Node 38) 75.151 psi 100 37.33 21/2" Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 101) 52.457 Pe 0.000 Pt 0.308 101 37.33 BL 111.0 0.03084 Total 10.0 59 37.33 2%" Dyna Flow 122.0 2.7030 T Len 159.3 Ftg 18.7 C = 120pt100) 52.765 Pe 0.000 Pt 21,642 100 37.33 BL 233.0 0.12165 Total 177.9 19 36.50 21/211 Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 59) 74.408 Pe 0.359 Pt 2.370 59 37.33 RN 233.0 0.12165 Total 19.5 18 36.50 4" Dyna Flow 461.9 4.3100 0 Len 10.0 Ftg 0.0 C=120 Pt 19) 77.137 Pe 0.000 Pt 0.947 19 36.50 CMI 694.9 0.09469 Total 10.0 I otai i'ressure at r'ioae 10) to-U04 psi 78 37.33 2h/2 Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 38) 75.151 Pe -0.359 Pt 0.154 38 36.50 RN 53.1 0.00788 Total 19.5 58 37.33 21/2 " Dyna Flow 2.7030 TIT Len 296.0 Ftg 37.3 C = 120 Pt 78) 74.944 Pe 0.000 Pt 2.626 78 37.33 BL 53.1 0.00788 Total 333.3 18 36.50 21/2 Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 58) 77.571 Pe 0,359 Pt 0.154 58 37.33 RN 53.1 0.00788 Total 19.5 17 36.50 4" Dyna Flow 694.9 4.3100 2E Len 0 42. Ftg 27.9 C = 120 Pt 18) 78.084 Pe 0.000 Pt 7.581 18 36.50 CM1 748.0 0.10850 Total 69-91 i otai rressure ax ivue I,, o.uuu p. 37 36.50 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 c = 120 Pt 38) 75.151 Pe 0.000 pf 0.995 38 36.50 CM2 713.7 0.09948 Total 10.0 77 37.33 2R' Dyna Flow -617.8 2.7030 1 Len 0.8 Ftg 18.7 C = 120 Pt 37) 76.145 Pe -0.359 Pt 0.459 37 36.50 RN 95.9 0.02355 Total 19.5 0 Copyright 2013 Sigma Development Group, Inc. Page 5 of 9 Pipe Information SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) From Elevl Pipe ID Flows Length ft 1 c Value [Total (Pt) psi ft Added GPM Inside Diameter Fittings I Notes Fitting ft Elev (Pe) psi To Elev2 Type Friction Loss I Total Total ft psi/ft [Frict (PI) psi 57 37.33 2%" Dyna Flow 2.7030 lIT Len 328.0 Ftg 37.3 C = 120 Pt 77) 76.244 Pe 0.000 P1 8.603 77 37.33 BL 95.9 0.02355 Total 365.3 17 36.50 21/20 Dyna Flow 2.7030 T Len 0.8 Ftg 18,7 c = 120 Pt 57) 84.847 Pe 0.359 P1 0.459 57 37.33 RN 95.9 0.02355 16 36.50 4" Dyna Flow 748.0 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 17) 85.666 Pe 0.000 pf 1.356 17 36.50 CM1 843.9 1 0.13563 Total 10.0 Total Pressure at Node 16) 87.022 psi 36 36.50 4" Dyna Flow 4.3100 0 Len 0 10. Ftg 0.0 C = 120 Pt 37) 76.145 Pe 0.000 P1 0.762 37 36.50 CM2 617.8 0.07617 Total 10.0 76 37.33 2%" Dyna Flow -523.8 2.7030 1 Len 8 0. Ftg 18.7 C = 120 Pt 36) 76.907 Pe -0.359 P1 0.442 36 36.50 RN 94.0 0.02270 Total 19.5 56 37.33 2%" Dyna Flow 2.7030 T14E,T 0 Len 332.0 Ftg 74.6 = 120 Pt 76) 76.990 Pe 0.000 Pf 9.230 76 37.33 BL 94.0 0.02270 Total 406.6 16 36.50 21/2" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 Pt 56) 86.220 Pe 0.359 P1 0.442 56 37.33 RN 94.0 0.02270 Total 19.5 15 36.50 4" Dyna Flow 843.9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 16) 87.022 Pe 0.000 P1 1.649 16 36.50 CM1 937.9 0.16491 Total 10.0 Total Pressure at Node 15) 88.6 11 psi 35 36.50 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 36) 76.907 Pe 0.000 P1 0.561 36 36.50 CM2 523.8 0.05612 Total 10.0 75 37.33 2%" Dyna Flow -424.4 2.7030 T L en 0.8 18.7 Pt 35) 77.468 c = 120 Pe -0.359 P1 0.490 35 - 36.50 RN 99.4 0.02514 19.5 55 37.33 2'/" Dyna Flow 2.7030 114E,T 332.0 tFtg74.6 C = 120 Pt 75) 77.599 Pe 0.000 P1 10.223 75 37.33 BL 99.4 0.02514 406.6 0 Copyright 2013 Sigma Development Group, Inc. Page 6 of 9 88' a" Dashboard Hydraullcs Pipe Information SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) From EleVi Pipe ID Flows Inside 1 I Length ft I C Value 1 I Total (Pt) psi ft Added GPM Diameter Fittings I Fitting ft I I I Elev (Pe) psi I Notes To EIev2 Type 'Friction Loss Total Tothi ft { psi/ft j Frict (Pf) psi 15 36.50 21/z Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 Pt 55) 87.822 Pe 0.359 Pt 0.490 55 37.33 RN 99.4 0.02514 Total 19.5 14 36.50 4" Dyna Flow 937,9 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 15) 88.671 Pe 0.000 Pt 1.987 15 36.50 CM1 1,037.3 0.19867 Total 10.0 Total Pressure at Node 14) 90.658 psi 34 36.50 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 c = 120 Pt 35) 77.469 Pe 0.000 Pt 0.380 35 36.50 CM2 424.4 0.03803 Total 10.0 74 37.33 2%" Dyna Flow -317.6 2.7030 T Len 0.8 Ftg 18.7 c = 120 Pt 34) 77.849 Pe -0.359 Pt 0.560 34 36.50 RN 106.8 0.02675 54 37.33 21/" Dyna Flow 2.7030 TI4E,T Len 332.0 Ftg 74.6 C = 120 Pt 74) 78.049 Pe 0.000 Pf 11.689 74 37.33 BL 106.8 0.02875 Total 406.6 14 36.50 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 54) 89.738 Pe 0.359 Pf 0.560 54 37.33 RN 106.8 0.02675 Total 19.5 4" Dyna Flow 1,037.3 4.3100 Len 1.5 Ftg 0.0 C = 120 Pt 14) 90.658 Pe 0.000 Pf 0.357 E436.5500 CM1 1,144.1 0.23818 Total 1.5 Total Pressure at Nooe iti; vi.uio psi 33 36.50 4" Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 34) 77.849 Pe 0.000 Pt 0.222 34 36.50 CM2 317.6 0.02224 Total 10.0 73 37.33 2'/a" Dyna Flow -211.0 2.7030 1 Len 0.8 Ftg 18.7 c = 120 Pt 33) 78.072 Pe -0.359 Pt 0.558 33 36.50 RN 106.6 0.02863 Total 19.5 53 37.33 21/2" Dyna Flow 2.7030 T/4E,T Len 332.0 Ftg 74.6 C = 120 Pt 73). 78.270 Pe 0.000 Pf 11.639 73 37.33 BL 106.6 0.02863 Total 406.6 13 36.50 21/2 Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 53) 89.909 Pe 0.359 Pt 0.558 53 37.33 RN 106.6 0.02863 Total 19.5 0 Copyright 2013 Sigma Development Group, Inc. Page 7 of 9 Dash á o boar o Pipe Information SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) From Elevl ft Pipe ID Flows Added Inside Length C Value I Total (Pt) psi GPM Diameter Fittings Fitting ft I Friction Loss psi/ft I Elev (Pe) psi I Notes To ft Elev2 Type Total Total ft Frict (Pf) psi 10 36.50 4" Dyna Flow 211.0 4.3100 0 Len 8.5T Ftg 0.0 c = 120 0.02224 Pt 13) 90.826 Pe 0.000 P1 0,189 13 36.50 CM1 317.6 Total 8.5 Total Pressure at Node 10) 91.015 psi 32 36.50 4' Dyna Flow 4.3100 0 Len 10.0 Ftg 0.0 C = 120 Pt 33) 78.072 Pe 0.000 Fl 0.104 33 36.50 CM2 211.0 0.01044 Total 10.0 72 37.33 2%" Dyna Flow -105.4 2.7030 1 Len 0.8 Ftg 18.7 c = 120 Pt 32) 78.176 Pe -0.359 Pf 0.549 32 36.50 RN 105.6 0.02816 Total 19.5 52 37.33 2%" Dyna Flow 2.7030 114E,T Len 332.0 Ftg 74.6 C = 120 Pt 72) 78.365 Fe 0.000 Pf 11,449 72 37.33 BL 105.6 0.02816 Total 406.6 12 36.50 2'/2" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 Ft 52) 89.814 Fe 0.359 Pt 0.549 52 37.33 RN 105.6 0.02816 Total 19.5 13 36.50 4" Dyna Flow 105.4 4.3100 0 Len 10.0 1 Ftg 0.0 C = 120 Pt 12) 90.722 Fe 0.000 Pf 0.104 12 36.50 CMI 211.0 0.01044 Total 10.0 Total Pressure at Node 13) 90.826 psi 31 36.50 4" Dyna Flow 4.3100 0 Len 0 10. Ftg 0.0 C = 120 Pt 32) 78.176 Fe 0.000 Pf 0.029 32 36.50 CM2 105.4 0.00289 Total 10.0 71 37.33 2h/a Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Ft 31) 78.205 Fe -0.359 Pf 0.546 31 36.50 RN 105.4 0.02803 Total 19.5 51 37.33 2%" Dyna Flow 2.7030 T/4E,T Len 332.0 Ftg 74.6 C = 120 Pt 71) 78.391 Fe 0.000 Pt 11.396 71 37.33 BL 105.4 0.02803 Total 406.6 11 36.50 2h/2 Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 51) 89.787 Fe 0.359 Fl 0.546 51 37.33 RN 105.4 0.02803 Total 19.5 12 36.50 4" Dyna Flow 4.3100 0 Len 0 10. Ftg 0.0 C = 120 Pt 11) 90.693 Pe 0.000 Pf 0.029 11 36.50 CMI 105.4 0.00289 Total 10.0 total Pressure at Node 12) 90.122 psi © Copyright 2013 Sigma Development Group, Inc. Page 8 of 9 1-411, 88600' Dashboard Hydraulics Pipe Information SR CARLSBAD OAKS BLDG A SYSTEM #1 (Remote Area 1) From Elv1 ft Pipe ID Flows Added Inside Length f h CValue [Total (Pt) )Si Fitting ft Elev (Pe) psi GPM I Diameter Fittings F Notes I To Elev2 Type ion Loss [ Total Total ft psi/ft [Fdct (Pt) psi 3 0.00 10" PVC CL200 9.4200 0 Len 350.0 Ftg 0,0 C = 150 0.00062 Pt 2) 135.137 Pe 0.000 P1 0.218 2 0.00 LU 450.2 Total 350.0 4 0.00 10" PVC CL200 9.4200 5EE Len 950.0 Ftg 61.5 c = 150 Pt 3) 135.355 Pe 0.000 P1 0.630 3 0.00 LU 450.2 0.00062 Total 1,011.5 1 0.00 10" PVC CL200 9.4200 SEE Len 910.0 Ftg 61.5 c = 150 0.00062 Pt 4) 135.985 Pe 0.000 Pt 0.605 4 o.00 LU 450.2 Total 971.5 Total Pressure at Node 1)136.591 psi 1 0.00 10" PVC CL200 9.4200 T,EE Len 180.0J Ftg 68.2 C = 150 Pt 2) 135.137 Pe 0.000 P1 1.454 2 0.00 LU 1,511.5 0.00586 Total 248.2 Total Pressure at Node 1)136.591 psi 9 36.50 4" Dyna Flow 4.3100 T Len 18.0 Ftg 27.9 c = 120 Pt 10) 91.015 Pe 0.000 Pf 17.190 10 36.50 FM 1,461.7 0.37473 Total 459 7 2.00 6' Sch 10 6.3570 T,BV/E Len 36.0 Ftg 67.9 C = 120 Pt 9) 108.206 Pe 14.939 P1 5.867 9 36.50 FR 1,461.7 0.05647 Total 103.9 6 0.00 6" Sch 10 6.3570 2E Len 0 4. Ftg 35.2 C = 120 Pt 7) 129.021 Pe 0.866 Pt 2.214 7 2.00 FR 1,461.7 0.05647 Total 39.2 2 0.00 8" PVC CL200 ______ 7.6800 T,GVICV ,EE,E Len 65.0 Fta 139.0 C=150 Pt 6) 132.101 Pe 0.000 P1 3.036 6 0.00 UN 1,461.7 0.01488 Total 204.0 Total Pressure at Node 2)135.137 psi 0 0.00 12° PVC CL200 11.2000 T,4E Len 190.0 '[..ic Ftg 185.9 Pt 1) 136.591 Pe 0.000 Pt 1.535 4psiIossforDDCshownas elevtion 1 0.00 UN 1,961.7 Total 375.9 0.00408 Total Pressure at Node 0) 138.126 psi 0 Copyright 2013 Sigma Development Group, Inc. Page 9 of 9 CL 150 U) U) U, 250 200 50 0 0 250 500 Remote Area 1 - Supply / Demand Graph 145.30 psi available at with System Flow of 1,713.4 GPM - Sprinkler Demand of 143.99 psi +0.9% -- Margin: I .1 474 AfI N185 A 750 1000 1250 1500 1750 Water Flow (GPM) 2000 B88OO Dashboard Hydraulics Hydraulics Summary Sheet Project Information I Calculation Date: 5/23/2016 10:10:26 AM SR CARLSBAD OAKS BUILDING A system ID drawing ref I SYSTEM #2 building NEW L 2870 WHIPTAIL LOOP construction CONC/WOOD CARLSBAD, CA occupancy WHSE contract # - - authority - Contractor Information - EPIC FIRE PROTECTION, INC. 765 TURTLE POINT WAY SAN MARCOS, CA 92069 calculated by ADAM BOISVERT telephone 760-310-6122 fax 760-798-0556 email EPICFIRE@COX.NET r_ Sprinklers in Remote FNo. Mfgr Mod SIN# Size K [ 12 1 VIKING I ESFR I VK503 J 3/4' 116.8 Hydraulics Criteria - density ESFR GPM/ft2 system type WETdesign std NFPA 13 remote area 12 HEADS ft' hard EXTRA spr coverage 35 PSI ft2 sprs flowing 12 figure calc'd volume 10948.5 gal curve - Flow Test static pressure 146.70 psi residual pressure 122.40 psi quantity flowing 8000.0 GPM elevation from if 0.00 ft date & time of flow test 2-18-16 location of flow test SITE 0 Copyright 2013 Sigma Development Group, Inc. Page 1 of 9 Ba8bo Dashbwrd Hydraulics Supply Analysis / Source / Static / Residual / Quantity / Node / Pressure / Pressure / Flowing Zero 146.70 psi 122.40 psi 8,000.0 GPM ( SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) / Pressure I Total / Total / System Available / Flow / sure / / R P res equired / 145.30 psi 11,713.4 GPM 143.99 psi Sprinkler Flow: 1463.4 GPM Additional Flows: 250.0 GPM Hose Flow at Zero: None Total System Flow: 1,713.4 GPM Maximum velocity in pipe 238 - 338 is 36.3 ft/sec Nodes Analysis Node Elev ft Device KFactor Minimum Flow GPM Node Pressure psi Actual Discharge GPM Notes 280 34.3 Sprinkler 16.80 121.15 52.00 121.15 281 34.3 Sprinkler 16.80 121.15 52.07 121.23 279 34.3 Sprinkler 16.80 121.15 52.14 121.31 276 34.3 Sprinkler 16.80 121.15 52.20 121.38 277 34.3 Sprinkler 16.80 121.15 52.26 121.44 275 34.3 Sprinkler 16.80 121.15 52.36 121.56 272 34.3 Sprinkler 16.80 121.15 52.88 122.16 273 34.3 Sprinkler 16.80 121.15 52.90 122.19 278 34.3 Sprinkler 16.80 121.15 53.01 122.32 271 34.3 Sprinkler 16.80 121.15 53.10 122.42 274 34.3 Sprinkler 16.80 121.15 53.26 122.61 270 34.3 Sprinkler 16.80 121.15 54.16 123.63 2 0.0 Hose Flow 141.66 250.0 0 Copyright 2013 Sigma Development Group, Inc. Page 2 of 9 8'OO" Pipe Information SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) From Elevl ft Pipe ID Flows Added T I Inside T Length ft I C Value I [Total (Pt) psi J I Fitting ft I Elev (Pe) psi GPM Diameter Fittings I I Notes To Elev2 Type in Friction Lossi I Total I ,jTotal ft[ psi/ft Fri1ct( psil 281 34.33 2%" Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 0.00668 Pt 280) 52.004 Pe 0.000 Pf 0.067 280 3.33 BL 48.5 Total 10.0 234 34.33 21/2" Dyna Flow 121.2 2.7030 T Len 6.0 Ftg 18.7 = 120 0.06772 Pt 281) 52.071 Pe 0.000 Pf 1.669 281 34.33 BL 169.8 Total 24.7 214 33.50 2',4" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 c = 120 Pt 234) 53.740 Pe 0.359 Pt 1.319 234 34.33 RN 169.8 0.06772 Total 19.5 213 33.50 4' Dyna Flow 4.3100 0 Len 8.0 Ftg 0.0 = 120 Pt 214) 55,419 Pe 0.000 Pt 0.056 214 33.50 CM2 169.8 0.00698 Total 8.0 1 Total Pressure at Node 213) 55.475 psi 279 34.33 2%" Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 280) 52.004 Pe 0.000 Pf 0.141 280 34.33 BL 72.6 0.01408 Total 10.0 278 34.33 21/2' Dyna Flow 121.3 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 279) 52.145 Pe 0.000 Pt 0.866 279 34.33 BL 193.9 0.08665 340 34.33 21/," Dyna Flow 122.3 2.7030 T Len 42.0 Ftg 18.7 C = 120 Pt 278) 53.011 Pe 0.000 Pf 12.986 278 34.33 BL 316.3 0.21412 Total 60.7 339 34.33 3' Dyna Flow 3.3140 0 Len 8.0 Ftg 0.0 c = 120 Pt 340) 65.998 Pe 0.000 Pt 0.635 340 34.33 BL 316.3 0.07936 Total 8.0 Total Pressure at Node 339) 66.632 psi 277 34.33 21/2" Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 0.00564 Pt 276) 52.200 Pe 0.000 Pt 0.056 276 34.33 BL 44.3 Total 10.0 233 34.33 21Y Dyna Flow 121.4 2.7030 T Len 6.0 Ftg 18.7 C = 120 Pt 277) 52.256 Pe 0.000 pf 1.597 277 34.33 BL 165.7 0.06478 Total 24.7 213 33.50 2/2" Dyna Flow 2.7030 1 Len 0.8 Ftg 18.7 C = 120 Pt 233) 53.853 Pe 0.359 Pf 1.262 233 34.33 RN 165.7 0.06478 Total 19.5 © Copyright 2013 Sigma Development Group, Inc. Page 3 of 9 088 0' Vashbowd Hydraulics Pipe Information SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) From Elevi Pipe ID Flows Inside Length ft I 1 c Value I Total (Pt) psi ft Added GPM Diameter Fittings Notes Fitting ft I Elev (Pe) psi To Elev2 Type in Friction Lossi Total Total ft psi/ft Frict (Pf) psi 212 33.50 4" Dyna Flow 169.8 4.3100 0 Len 8.01 Ftg 0.0 c = 120 Pt 213) 55.475 Pe 0.000 P1 0.197 213 33.50 CM2 335.5 0.02462 Total 8.0 Total Pressure at Node 212) 55.672 psi 275 34.33 2%" Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 0.01573 Pt 276) 52.200 Pe 0.000 Pf 0.157 276 34.33 BL 77.1 Total 10.0 274 34.33 21/2" Dyna Flow 121.6 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 275) 52.357 Pe 0.000 Pf 0.906 275 34.33 BL 198.7 0.09059 Total 10.0 339 34.33 2W Dyna Flow 122.6 2.7030 T Len 42.0 Ftg 18.7 C = 120 Pt 274) 53.263 Pe 0.000 Pf 13.369 274 34.33 BL 321.3 0.22043 Total 60.7 338 34.33 3" Dyna Flow 316.3 3.3140 0 Len 8,0 Ftg 0.0 0=120 Pt 339) 66.633 Pe 0.000 Pf 2.323 339 34.33 BL 637.5 0.29031 l 8.0 Total Pressure at Node 338) 68.955 psi 273 34.33 2%" Dyna Flow 2.7030 0 Len 10.0 Ftg 0.0 = 120 Pt 272) 52.879 Pe 0.000 Pt 0.026 272 34.33 BL 28.8 0.00255 Total 10.0 232 34.33 21/2 Dyna 122.2 2.7030 T Len 6.0 Ftg 18.7 C= 120 Pt 273) 52.904 Pe 0.000 Pf 1.345 273 34.33 BL ______ 151.0 0.05456 Total 24.7 212 33.50 21/2" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 232) 54.249 Pe 0.359 P1 1.063 232 34.33 RN 151.0 0.05456 Total 19.5 211 33.50 4" Dyna Flow 335.5 4.3100 0 Len 0 8. Ftg 0.0 C = 120 Pt 212) 55.672 Pe 0.000 Pt 0.392 212 33.50 CM2 486.5 0.04896 Total 8.0 Total Pressure at Node 211) 56.063 psi 271 34.33 21/2' Dyna Flow 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 272) 52.879 Pe 0.000 Pf 0.224 272 34.33 BL 93.3 0.02239 Total 10.0 270 34.33 21/2- Dyna Flow 122.4 2.7030 Len 10.0 Ftg 0.0 C = 120 Pt 271) 53.103 Pe 0.000 Pt 1.055 _________ 271 34.33 BL 215.7 0.10553 Total 10.0 0 Copyright 2013 Sigma Development Group, Inc. Page 4 of 9 088 a' Pipe Information SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) From Elevi Pipe ID Flows T I Length CValue [Total (Pt) psi ft Added GPM Inside Diameter Fittings I I I I I Notes Fitting ft Elev (Pe) psi Elev2 in Friction Loss To Type Total Total ft[ psi/ ft psi 338 34.33 2%" Dyna Flow 123.6 Len 42.0 C 120 Pt 270) 54.158 270 34.33 BL Total 60.7 339.4 0.24397 Pt 14.797 2.7030 1 Ftg 18.7 Fe 0.000 238 34.33 3" Dyna Flow 637.5 Len 16,0 C= 120 Pt 338) 68.955 338 34.33 BL 976.9 0.63940 Pt 23.263 3.3140 2E Ftg 20.4 Pe 0.000 239 34.33 3" Dyna Flow -159.6 Len 8.0 c = 120 Pt 238) 92.218 238 34.33 BL 817.3 Total 8.0 0.45967 Pt 3.677 3.3140 0 Ftg 0.0 Pe 0.000 240 34.33 3" Dyna Flow -146.1 Len 8.0 239 34.33 BL 671.2 Total 8.0 0.31935 Pf 2.555 3.3140 0 Ftg 0.0 Fe 0.000 C = 120 Pt 239) 95.895 224 34.33 2%" Dyna Flow Len 243.0 240 34.33 BL 131.8 Total 280.3 0.04240 Pt 11.884 2.7030 2T Ftg 373 Fe 0.000 C = 120 Pt 240) 98.450 204 33.50 214 Len 0.8 Dyna Flow C = 120 Pt 224) 110.334 224 34.33 RN 131.8 Total 19.5 0.04240 Pf 0.826 2.7030 1 Ftg 18.7 Fe 0.359 Total Pressure at Node 204) 111.520 psi 223 34.33 2%" Dyna Flow Len C = 120 Ft 239) 95.895 239 34.33 BL 146.1 Total 280.3 0.05128 Pt 14.373 0 243. 2.7030 2T Ftg 373 Pe 0.000 203 33.50 21/2" Dyna Flow Len C= 120 Pt 223) 110.268 223 34.33 RN 146.1 Total 19.5 0.05128 Pf 0.999 8 0. 2.7030 T Ftg 18.7 Pe 0.359 Total Pressure at Node 20) 1 i i.627 PSI 222 34.33 2Y2' Dyna Flow Len C= 120 Pt 238) 92.218 238 34.33 BL 159.6 Total 299.0 0.06043 Pf 18.065 0 243. 2.7030 T,2EIT Ftg 56.0 Pe 0.000 202 33.50 2'/z" Dyna Flow Len 0.8 C = 120 Pt 222) 110.283 222 34.33 RN 159.6 Total 19.5 0.06043 Pt 1.177 T Ftg 18.7 Fe 0.359 Total Pressure at Node 202) 111.819 psi r241 I34.33 3" Dyna Flow I Len 10.0 I c = 120 Pt 240) 98.450 [ 240 34.33 BL 3.3140 0 Ftg 0.0 Fe 0.000 Total 10.0 Pf 2.131l 0.21314 0 Copyright 2013 Sigma Development Group, Inc. Page 5 of 9 fl 88OO Dash HydIvillIcs Pipe Information SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) From Elevi Pipe ID Flows Added GPM T I Inside I Diameter I I Fittings TLength 1 C Value Friction Loss 1 psi/ft [Total (Pt) psi I I Notes I [Frict(Pf) psil Fitting ft I I Elev (Pe) psi I To Elev2 Type Total ITotal 246 34.33 3" Dyna Flow -484.4 3.3140 E,4EE Len 10.0 Ftg 27.7 C= 120 0.00312 Pt 241) 100.582 Pe 0.000 pf 0.118 241 34.33 BL 55.0 Total 37.7 242 34.33 2%" Dyna Flow 2.7030 OlE Len 100.0 Ftg 9.3 C= 120 Pt 246) 100.699 Pe 0.000 Pt 0.921 246 34.33 BL 55.0 0.00843 Total 109.3 Total Pressure at Node 242) 101.620 psi 242 34.33 3" Dyna Flow 3.3140 0 Len 10,0 Ftg 0.0 C = 120 Pt 241) 100.582 Pe 0.000 Pt 1.039 241 34.33 BL 365.8 0.10388 Total 10.0 243 34.33 2%" Dyna Flow -91.6 2.7030 T Len 8.0 Ftg 18.7 c = 120 1 Pt 242) 101.620 Pe 0.000 Pt 4.382 242 34.33 BL 274.2 0.16443 Total 26.7 244 34.33 2'/," Dyna Flow 98.8 2,7030 0 Len 8.0 Ftg 0.0 0=120 Pt 243) 106.003 Pe 0.000 Pt 0.575 243 34.33 BL 175.4 0.07193 Total 8.0 245 34.33 2%" Dyna Flow -92.4 2.7030 0 Len 8.0 Ftg 0.0 c = 120 Pt 244) 106.578 Pe 0.000 pf 0.144 244 34.33 BL 83.0 0.01802 229 34.33 21/2" Dyna Flow 2.7030 115E Len 151.8 Ftg 65.3 C = 120 Pt 245) 106.722 Pe 0.000 Pt 3.910 245 34.33 BL 83.0 0.01802 Total 217.0 209 33.50 21/2" Dyna Flow 2.7030 1 Len 0.8 Ftg 18.7 0=120 Pt 229) 110.632 Pe 0.359 Pt 0.351 229 34.33 RN 83.0 0.01802 Total 19.5 208 33.50 6" Sch 10 6.3570 0 Len 8.0 Ftg 0.0 c = 120 Pt 209) 111.343 Pe 0.000 Pt 0.002 209 33.50 CMI 83.0 0.00028 Total 8.0 Total Pressure at Node 208) 111.345 psi 228 34.33 21/2' Dyna Flow 2.7030 l/T Len 143.8 Ftg 373 c = 120 Pt 244) 106.578 Pe 0.000 pf 3.979 244 34.33 BL 92.4 0.02198 Total 181.1 208 33.50 2%" Dyna Flow 2.7030 1 Len 0.8 Ftg 18.7 c = 120 Pt 228) 110.557 Pe 0.359 Pt 0.428 _____ 228 - 34.33 RN 92.4 0.02198 Total 19.5 , © Copyright 2013 Sigma Development Group, Inc. Page 6 of 9 oo Dashboard Hydraulics Pipe Information SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) From Elevi Pipe ID Flows Inside Length ft' I C Value jTotal (Pt) PSiJ ft Added GPM Diameter Fittings I Notes Fitting ft Elev (Pe) psi To EIev2 Type in 'Friction Loss psij !Fct(N) Total Total ft psi/ft 207 33.50 6" Sch 10 83.0 6.3570 0 Len 8.0 i Ftg 0.0 C = 120 Pt 208) 111.345 Pe 0.000 Pt 0.009 208 33.50 CM1 175.4 0.00112 Total 8.0 Total Pressure at Node 207) 111.354 psi 227 34.33 2%- Dyna Flow 2.7030 TIT Len 143.8 Ftg 37.3 C= 120 0.02489 Pt 243) 106.003 Pe 0.000 Pf 4.507 243 34.33 BL 98.8 Total 181.1 207 33.50 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 120 Pt 227) 110.509 Pe 0.359 Pt 0.485 Total 19.5 227 34.33 RN 98.8 0.02489 206 33.50 6" Sch 10 175.4 6.3570 0 Len 8,0 Ftg 0.0 c = 120 0.00255 Pt 207) 111.354 Pe 0.000 Pf 0.020 207 33.50 CM1 274.2 Total 8.0 Total Pressure at Node 206) 111.374 psi 226 34.33 21/2" Dyna Flow 2.7030 T Len 143.8 Ftg 18.7 C= 120 0.05165 Pt 242) 101.620 Pe 0.000 Pt 8.388 242 34.33 BL 146.6 Total 162.4 206 33.50 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 226) 110.008 Pe 0.359 Pf 1.006 226 34.33 RN 146.6 0.05165 Total 19.5 205 33.50 6' Sch 10 274,2 6.3570 0 Len 10.0 Ftg 0.0 C = 120 Pt 206) 111.374 Pe 0.000 Pt 0.056 206 33.50 CM1 420.8 0.00564 Total 10.0 Total Pressure at Node 205) 111.431 psi 225 34.33 2%" Dyna Flow 2.7030 T,4EE Len 243.8 Ftg 37.3 C = 120 Pt 241) 100.582 Pe 0.000 Pt 9.809 241 34.33 BL 118.6 0.03490 Total 281.1 205 33.50 21/2" Dyna Flow 2.7030 1 Len 0.8 Ftg 18.7 C= 120 Pt 225) 110.391 Pe 0.359 Pf 0.680 225 34.33 RN 118.6 0.03490 Total 19.5 204 33.50 6" Sch 10 420.8 6.3570 0 Len 10.0 Ftg 0.0 C= 120 Pt 205) 111.431 Pe 0.000 Pt 0.089 205 33.50 CMI 539.5 0.00893 203 33.50 6" Sch 10 131.8 6.3570 0 Len 8.0 Ftg 0.0 C = 120 0.01338 Pt 204) 111.520 Pe 0.000 Pt 0.107 204 33.50 CM1 671.2 Total 8.0 0 Copyright 2013 Sigma Development Group, Inc. Page 7 of 9 oo Dash draulics Pipe Information SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) From Ev1 Pipe ID Flows Inside Length ft I C Value I ITotal (Pt) psi I ft Added GPM Diameter Fillings I Notes Filling ft I Elev (Pe) psi To Elev2 Type in Friction Loss ft ! Total ft psi/ft IMct(N) psij 202 33.50 6" Sch 10 146.1 6.3570 0 Len 10.0 Ftg 0.0 C= 120 0.01926 Pt 203) 111.627 Pe 0.000 Pt 0.193 203 33.50 CM1 817.3 Total 10.0 201 33.50 6" Sch 10 159.6 6.3570 0 Len 10.0 Ftg 0.0 C= 120 Pt 202) 111.820 Pe 0.000 Pt 0.268 202 33.50 1 CMI 976.9 0.02679 Total 10.0 Total Pressure at Node 201) 112.088 psi 210 33.50 4" Dyna Flow 4.3100 0 Len 10,0 Ftg 0.0 C= 120 Pt 211) 56.064 Pe 0.000 Pt 0.136 211 33.50 CM2 243.8 0.01364 Total 10.0 230 34.33 2%" Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C=120 Pt 210) 56.200 Pe -0.359 Pf 2.577 210 33.50 RN 243.8 0.13229 Total 19.5 220 34.33 21/2" Dyna Flow 2.7030 T/2E,T Len 0 330. Ftg 56.0 C = 120 Pt 230) 58.418 Pe 0.000 Pt 51.057 230 34.33 BL 243.8 0.13229 Total 386.0 200 33.50 2'/a' Dyna Flow 2.7030 T Len 0.8 Ftg 18.7 C = 120 Pt 220) 109.474 Pe 0.359 Pf 2.577 220 1 34.33 RN 243.8 0.13229 Total 19.5 Total Pressure at Node 200) 112.411 psi 231 34.33 2%" Dyna Flow 2.7030 T 8 Len 0.0 Ftg 18.7 = 120 Pt 211) 56.063 Pe -0.359 Pf 2.556 211 33.50 RN 242.7 0.13123 Total 19.5 221 34.33 21/2" Dyna Flow 2.7030 T/2E,T Len 332.0 Ftg 56.0 0=120 Pt 231) 58.260 Pe 0.000 Pt 50.911 231 34.33 BL 242.7 0.13123 Total 388.0 201 33.50 2%" Dyne Flow 2.7030 1 8 Len 0.0 Ftg 18.7 = 120 Pt 221) 109.171 Pe 0.359 Pt 2.556 221 34.33 RN 242.7 0.13123 Total 19.5 200 33.50 6" Sch 10 976.9 6.3570 0 Len 8.0 Ftg 0.0 C=120 Pt 201) 112.088 Pe 0.000 Pt 0.323 201 33.50 CMI 1,219.6 0.04040 Total 8.0 Total Pressure at Now UU) ii .411 psi 3 0.00 10" PVC CL200 9.4200 I 0 Len 350.01 Ftg 0.0 C = 150 Pt 2) 141.661 Pe 0.000 Pt 0.170 2 0.00 LU 393.2 0.00049 I Total 350.0 © Copyright 2013 Sigma Development Group, Inc. Page 8 of 9 Dashboard Hwo'rav//cs Pipe Information SR CARLSBAD OAKS BUILDING A SYSTEM #2 (Remote Area 1) From Elevl Pipe ID Flows I I I Length ft I I C Value I Total (Pt) psi 1 ft Added GPM Inside Diameter Fittings ' Notes Fitting ft Elev (Pe) psi 1F(P psi1 - To ft EIev2 I Type in Friction Loss Total1 Total 1 psi/ft 4 0.00 10" PVC CL200 9.4200 5EE Len 950.0 Ftg 61,5 0=150 Pt 3) 141.831 Pe 0.000 Pf 0.491 3 0.00 LU 393.2 0.00049 Total 1,011.5 1 0.00 10" PVC CL200 9.4200 5EE Len 910.0 Ftg 61.5 0=150 Pt 4) 142.321 Pe 0.000 Pf 0.471 4 0.00 LU 7393.2] i 0.00049 Total 971.5 Total Pressure at Node 1)142.793 psi 1 1 0.00 10" PVC CL200 9.4200 jEI Len 180.0 Pt 2) 141.661 0.000 Pf 1.132 2 0.00 LU 1,320.2 Ftg 68._E__59_IPe 6 Total 248.2 Total Pressure at Node 1)142.793 psi 9 33.50 6" Sch 10 6.3570 3E Len 52.9 Ftg 52.8 0=120 Pt 200) 112.411 Pe 0.000 Pf 5.983 200 33.50 FM 1,463.4 0.05659 Total 105.7 7 2.00 6" Sch 10 6.3570 BV/E Len 31.5 Ftg 30.2 C=120 Pt 9) 118.394 Pe 13.640 Pf 3.490 9 33.50 FR 1,463.4 0.05659 Total 61.7 6 0.00 6" Sch 10 6.3570 2E Len 4.0 Ftg 35.2 0=120 Pt 7) 135.533 Pe 0.866 Pf 2.219 7 2.00 FR 1,463.4 0.05659 Total 39.2 2 0.00 8" PVC CL200 7.6800 T , GVICV ,EE,E Len 65.0 Ftg 139.0 0=150 Pt 6) 138.619 Pe 0.000 Pf 3.042 6 L 0.00 UN 1,463.4 0.01491 Total 204.0 Totai Pressure at Node ) 14i.uuu psi 0 0.00 12" PVC CL200 11.2000 I T,4E I Len 190.01 Ftg 185.9 C 150 Pt 1) 142.793 Pe 0.000 Pf 1.195 4 psi loss for DDC shown as elevtion 0.00 UN 11,713.4 0.003181 I I Total 3759 Total Pressure at Node U) 1.00 PSI 0 Copyright 2013 Sigma Development Group, Inc. Page 9 of 9 M/A7EIRIAL DATA SUBh1177AL SR CARLSBAD OAKS BUILDING A EPIC FIRE PROTECTION, INC. 75 TURTLE POINT WAY SAN MARCOS, CA 920S (700)310-6122 FAX(70)78-055 ASI 60126 2870 WHIPTAIL LP January 17, 2014 Sprinkler 123a Sprinkler 123b January 17, 2014 TECHNICAL ESFR PENDENT SPRINKLER riJ I VJ 4 VK503 (K1 6.8) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.COm DESCRIPTION Viking Early Suppression Fast Response (ESFR) Pendent Sprinkler VK503 is a fast response fusible element type sprinkler designed for early fire suppression. With a 16.8 (242 metric") nominal K-Factor and special deflector, this sprinkler produces large, high-momentum water droplets in a hemispheric pattern below the deflector. This permits penetration of the fire plume and direct wetting of the burning fuel surface while cooling the atmosphere early in the development of a high-challenge fire, Viking Sprinkler VK503 may be used in the protection of ordinary types of storage. However, it is primarily intended to protect the following types of storage, which tend to produce severe-challenge fires: palletized and solid pile storage and single, dou- ble, multiple row, and portable open rack storage (no open-top containers or solid shelves). Viking ESFR Pendent Sprinkler VK503 provides protection of most common storage materials, including: —Encapsulated or unencapsulated Class I, It, Ill, and IV commodities". —Cart oned and uncartoned unexpanded plastics". —Carloned expanded plastics". -Refer the Approval Charts and Design Criteria on pages 123c-n for cULus Listing and FM Approval requirements that must be followed. In addition, some storage arrangements of rolled paper, aerosols, and rubber tires may be protected by Viking ESFR Pendent Sprinkler VK503. LISTINGS AND APPROVALS cULus Listed: Category VNWN Successfully meets new UL 1767 test standard and compliance program for ESFR sprinklers installed in rack storage with high clearances to ceiling (20 ft or greater) FM Approved: Class 2027 NYC Approved: MEA 89-92-B, Volume 41 Refer to Approval Chart 1 and Design Criteria on pages 123c-d for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 123d for FM Approval requirements that must be followed. TECHNICAL DATA Specifications: Available since 2007. Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4" NPT or 20 mm BSP Nominal K-Factor: 16.8 U.S. (242 metric") Metric K-factor measurement strewn is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Overall Length: 2-718' (73 mm) Defector Diameter: 1-3/4" (44.5 mm) Covered by one or more of the following patents: US5.829,532; US6,059.044; US6.336,509; US6,502,643; US6,868.917;AU722593; (36233b/ ti Material Standards: Frame Casting. Brass UNS-004400 Deflector: Phosphor bronze UNortuuo iihking technical D ha may be found tin Seat and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS- The Viking Corporation's Web site at S30400 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with littp:Ilwwwvlking9rOuPlflC.COm. Teflon Tape The Web site may Include a more recent Compression Screw: Stainless Steel UN5531603 edition of this Technical Data Page. Trigger and Support: Stainless Steel UNS-531600 Fusible Element Assembly: Beryllium Nickel, coated with black acrylic paint. Ordering information: (Also refer to the current Viking price list.) Order ESFR Pendent K16.8 Sprinkler VK503 by first adding the appropriate suffix for the sprinkler finish and then the appropnate suffix for the temperature rating to sprinkler base part number. Form No. F_120106 Replaces page 123a-f, dated September 9, 2011. (UL 1767 Note.) The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Finish Suffix: Brass =A Temperature Suffix: 165 'F (74 'C) = C, 205 'F (96 'C) = E For example, sprinkler VK503 with a Brass finish and a 165 'F (74 'C) temperature rating = Part No. 14073AC. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrench: Part No. 13635W/B (double-ended wrench - Use Side A. Side B is for use with 1<25.2 ESFR Pendent Sprinkler VK510) Available since 2008. Sprinkler Cabinet: Twelve-head capacity: Part No. 01725A (available since 1971) INSTALLATION WARNING: Viking sprinklers are manufactured and tested to meet rigid requirements of the approving agency. The sprinklers are designed to be installed in accordance with recognized installation standards. System design must be based on ESFR design guidelines described in the latest edition of Viking technical data, applicable FM Global Loss Prevention Data Sheets, the latest NFPA Standards, the latest standards of Verband der Sachverxicherer (lidS), Loss Prevention Council (LPCB), the Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards whenever applicable. Deviation from the standards or any alteration to the sprinkler after it leaves the factory including, but not limited to: painting, plating, coating, or modification, may render the sprinkler inoperative and will automatically nullify the approval and any guarantee made by The Viking Corporation. Sprinklers must be handled with care. They must be stored in a cool, dry place in their original shipping container. Never install sprinklers that have been dropped or damaged in any way. Such sprinklers should be destroyed immediately. NOTE: Wet pipe systems must be provided with adequate heat. The sprinklers must be installed after the piping is in place to prevent mechanical damage. Before installing, be sure to have the appropriate sprinkler model and style, with the correct orifice size, temperature rating, and response characteristics. With the sprinkler contained in the plastic protective cap, apply a small amount of pipe-joint compound or tape to the male threads only, while taking care not to allow a build-up of compound in the sprinkler orifice. Use ONLY sprinkler wrench 13635W1B (shown in Figure 1) for installing ESFR Sprinkler VK5031 With the sprinkler con- tained in the protective cap, install the sprinkler onto the piping by applying the sprinkler wrench to the sprinkler wrench flats only, while taking care not to damage the sprinkler operating parts. DO NOT use any other type of wrench, as this could damage the unit. DO NOT use the sprinkler deflector or fusible element to start or thread the sprinkler into a fitting. DO NOT exceed 50 It. lbs. of torque (hand tight, plus approximately two full turns with the wrench) to install these sprinklers. Higher levels of torque may distort the sprinkler inlet with consequent leakage or impairment of the sprinkler. After installation, the entire sprinkler system must be tested. The test must be conducted to comply with the Installation Standards. Make sure the sprinkler has been properly tightened. If a thread leak occurs, normally the unit must be removed, new pipe-joint compound or tape applied, and then reinstalled. This is due to the fact that when the joint seal is damaged, the sealing compound or tape is washed out of the joint. Immediately replace any damaged units, using the special sprinkler wrench only. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND 1lFINISHES "prinkler if tiftetat I 'rpnnkfer No(inal Maginiritni Ariibleot F P Cl 10_aU T raturo Rating' Coiling Tomp-oruturci Ordinary 165 'F (74 'C) 100 'F (38 'C) None Intermediate 205 'F (96 'C) 150 'F (65 'C) White Sprinkler Finish: Brass Footnotes The sprinkler temperature rating is stamped on the detector. 'Based on NFPA-13. Oiler limits may apply, depending on fire loading, sprinkler locatien, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Figure 2: ESFR Pendent Sprinkler VK503 Dimensions A January 17, 2014 Sprinkler 123c Sprinkler 123d January 17, 2014 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 TelephOflc: 269945-91,01 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcs©vikingcorp.com Approval Chart I (UL) rs - ESFRPendent Sprinkler VK503 Msxini'um175 PSI (12bnrWWP MX+-Enontpvot Base Part SIN Thread Size Nominal K-Factor Overall Length (RStings efer also to DesignC on page l2)df Number NPT BSP U.S. metrIc' Inches mm cULus5 NYC' VdS LPCB (( I 0 14073 V1<503 3/4" - 16.8 242 2-7/8 73 Al Al - - - - 14818 V1<503 - 20 mm 16.8 242 2-7/8 73 Al I Al - - - - Approved Temperature Ratings Approved Finish A - 165 'F (74 'C) and 205 'F (96 'C) I - Brass Footnotes 'Bate part number shown. For complete part number, refer to the price list. 2 Met/c (-Factor measurement shown is when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-Factor shown by 10.0. 'This chart shows listings and approvals available at the time of printing. Other approvals maybe in process. 'Refer to the latest standards of NFPA 13. 'Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. 'Accepted for use. City of New York Department of Buildings, MEA Number 89-92-E, Vol. 41. \'rer1Ch—., Flat - Protective SpHrrkier, CCLP Use Side A For ESFR Pendent K16.8 Sprini,ler VK503 Figure 1: ESFR Pendent Sprinkler Wrench 13635WlB _____ SPRINKLER] NumW&I",VK503 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384.5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com -. UbtatiaN_.RrrEp)A_iIL (Also-fefer to ApprovalC'tay1 __pag 123c) cULus_LisBon_Reaufremengs: ESFR Pendent Sprinkler VK503 is cULus Listed as indicated in the Approval Chart for installation In accordance with the latest appropriate NFPA standards (Including NFPA 13) for ESFR Pendent K16.8 (242) Sprinklers, for Protecting rack storage of certain speckled materials up to 35 11(10.7 m) high to buildings with 40 ft 112.2 ml high ceilings with NO In-rock sprinklers. Protecting rack storage of certain specified materials up to 40 8(12.2 m) high in buildings with 45 ft (13.7 ml high ceilings with one row of in- rack sprinklers. NFPA 13 Indicates the following for ESFR pendent sprinklers having a 16.8 nominal K-Factor: Position the doliccict a maximum of 14" (386 mm) and a minimum of 6" (152 mm) below the ceiling. The minimum area of coverage allowed per sprinkler is 64 ft' (5.8 rn') per NFPA 13. Maximum Roof or Ceiling Slope: 2 in 12 (167 mmim or 9.5 degrees). Sprinkler Position: Approved for use only in the pendent positron. Align the deflector parallel With the ceiling or roof. System Type: Wet systems only. Deflector Distance from Walls: At least 4' (102 mm) from walls, and no more than one-hart the allowable distance permitted between sprinklers, Clearance from Deflector to Top of Storage: At least 36' (914 mm). Maximum Distance Between Sprinklers: The maximum orea of coverage allowed per sprinkler is 1008' (9.3 m')'. - For buildings over 3011(9.1 m) high, spacing between sprinklers and/or branch lines mast be from 8 to 10 ft (2.4 to 3.1 m)'. For building heights up to 30 ft (9.1 m), the spacing allowed between sprinklers and/or branch lines is 8 to 12 ft (2.4 to 3.7 m), provided the area covered per sprinkler does not exceed the maximum 180 ft' (9.3 nt') allowed". "Refer In the Installation Standards for permissible deviations from the maximum spnnlderlbranth line spacing rules above, to eliminate obstruc- tions created by trusses and bar mists when using ESFR sprinklers. Minimum Area of Coverage: The minimum area of coverage allowed per sprinkler is 64 ft' )5.8 m9. Note: If the ceiling is beam and girder or panel construction, locate sprinklers in the bays rather than under the beams. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Viking ESFR Pendent Sprinklers are to be installed in accordance with the latest edition of Viking technical data, the latest standards of VdS, NFPA, and any other Authorities Having Jurisdiction, and also with provisions of governmental codes, ordinances, and standards whenever applicable. 2-9/1E' DIA. (65,0 writ) RATING FLATS THERMAL 3-5/8 SENSING 12.1 mm) WRENCc ELEMENT 1/2' (12.7 mm( NOMINAL 1-5/8 MAKE-IN (41,3 mmj NFl FIGURE 1 MODEL ESFR-17 UPRIGHT SPRINKLER, 16.8K EARLY SUPPRESSION, FAST RESPONSE TFP3IG Page 2 of 4 General Description TYCO Model ESFR-17 Upright Sprin- klers are Early Suppression, Fast Response (ESFR) sprinklers having a nominal K-factor of 16.8 (Ref. Figure 1). They are suppression mode sprinklers that are especially advantageous as a means of eliminating in-rack sprinklers when protecting high-piled storage. Model ESFR-17 Sprinklers are primarily used for ceiling-only sprinkler protec- tion of (but not limited to) the following storage applications: most encapsulated or non-encap- sulated common materials including cartoned, unexpanded plastics cartoned, expanded plastics some storage arrangements of rubber tires and roll paper For more specific criteria, refer to Table A in this technical data sheet as well as the applicable design standard. The Model ESFR-17 Upright Sprin- klers provide the system designer with an upright option to the traditional pendent ESFR Sprinklers. With a K-fac- tor of 16.8, Model ESFR-17 Sprinklers provide system designers with hydrau- lic and sprinkler placement options not presently available to traditional ESFR Sprinklers having a K-factor of 14.0. In particular, the Model ESFR-17 Upright Sprinklers are designed to operate at substantially lower-end head pressures compared to ESFR Sprinklers with 14.0 K-factors. This feature offers flexibility IMPORTANT Always refer to Technical Data Sheet TFP 700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or Its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause It to operate prematurely. Page 1 of 4 when sizing system piping and posi- tioning the system piping with respect to the ceiling. Applications for the TYCO ESFR Sprin- klers are expanding beyond currently recognized installation standards. For information on research fire tests that may be acceptable to an authority having jurisdiction, contact Tyco Fire Protection Products (TFPP) Technical Services. The Model ESFR-17 Upright Sprinklers described herein must be Installed and maintained in compliance with this doc- ument as well as with the applicable standards of the National Fire protec- tion Association (NFPA), in addition to the standards of any authorities having jurisdiction (e.g., FM Global). Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. In all cases, the appropriate NFPA or FM Global installation standard must be referenced to ensure applicabil- ity and to obtain complete installa- tion guidelines. The general guidelines in this data sheet are not intended to provide complete installation criteria. Sprinkler Identification Number (SIN) TY7126 DECEMBER 2015 Technical Data Approvals FM Approved CE Certified (Certificate of Conformity 1725-CPD-H0O12) Maximum Working Pressure 175 psi (12.1 bar) Pipe Thread Connections 3/4 Inch NFl or ISO 7-R 3/4 Discharge Coefficient K=16.8 gpmlpsit° (241.9 1pmThart"2) Temperature Ratings 165'F (74"C) and 212'F (105'C) Finish Natural Brass Physical Characteristics Frame .............................Brass Deflector... ...................... Copper Compression screw .........stainless Steel Hook....... ..................... MONEL Strut .. .......................... MONEL Link Assembly ................ Solder. Nickel Button .............................erass Sealing Assembly.. Beryllium Nickel w/TEFLON Election Spring ..... ............. INCONEL Collector Nut. ....................... Brass TFP3IG Components. 1 - Frame 2 - Deflector 3 - Compression Scww 4 - Hook S - Strut 6 - Link Assembly 7 - Button 8 - Sealing Assembly 9 - Ejection Spring 10 - Detector Nat Design Criteria The following general guidelines pro- vided for the TYCO Model ESFR-17 Upright Sprinklers may be used for quick reference. The National Fire Protection Associa- tion (NFPA) and FM Global (FM Approv- als) provide installation standards that must be used to properly design an automatic sprinkler system utilizing Early Suppression, Fast Response (ESFR) Sprinklers. The guidelines pro- vided by NFPA and FM Global may differ; consequently, the appropriate standard must be used for a given installation. In all cases, the appropriate NFPA or FM Global Installation standard must be referenced to ensure applicabil- ity and to obtain complete installation guidelines, since the following general guidelines are not intended to provide complete Installation criteria. In addition to this technical data sheet, the following data sheets describe other TYCO ESFR Sprinklers: TFP3I2 Model ESFR-25 (TY9226) K25.2 Pendant Sprinkler TFP31S Model ESFR-17 (TY7226) K=16.8 Pendent Sprinkler TFP3IB Model ESFR-1 (T'f6226) K=14.0 Pendent Sprinkler System Type Wet Pipe Roof Construction Unobstructed or obstructed construc- tion (e.g., smooth ceiling, bar joists, beam and girder, and so forth) Where the depths of the solid struc- tural members (e.g., beams and stem) exceed 12 inches (302 mm), install ESFR Sprinklers in each channel formed by the structural members. Ceiling Slope Maximum 2 inch rise for 12 inch run (16.7%) Maximum Coverage Area 100 ft.2 (9,3 m2) In some cases, the installation stan- dards permit a greater coverage area. Minimum Coverage Area 64 ft.2 (5.8 in2) per NFPA 13 / FM Global 2-0 Maximum Spacing 12 feet (3,7 m) for building heights up to 30 feet (9,1 m) 10 feet (3,1 m) for building heights greater than 30 feet (9,1 m) Minimum Spacing 8 feet (2,4 m) Minimum Clearance to Commodity 36 inches (914 mm) NFPA 13 Deflector-to-Ceiling Distance 3 to 12 inches (76,2 to 304 mm) FM Global Centerline of Thermal Sensing Element-to-Ceiling Distance Refer to FM Global 2-0 for Storage Sprinklers. Obstructions below Upright ESFR Sprinklers, Including Branchlines Per the requirements of FM, obstruc- tions below upright ESFR Sprinklers can be ignored as follows open-web bar joists or trusses having chords no more than 4 inches (102 mm) wide bridging or wind bracing no more than 4 inches (102 mm) wide individual pipes and conduit 4 inches (102 mm) diameter or less 3 Inch (DN80) pipe size or less will not require sprigs) individual groups of smaller pipe or conduit having a total width of 4 inches or less Operation The fusible link assembly is com- prised of two link halves that are joined together by a thin layer of solder. When the rated temperature is reached, the solder melts and the two link halves separate, activating the sprinkler and flowing water. tqco Worldwide Fire Protection Contacts www.tyco-fire.com Products Model ESFR-17 16.8 K-factor Upright Sprinkler Early Suppression, Fast Response Installation TYCO Model ESFR-17 Early Suppres- sion, Past Response 16.8K Upright Sprinklers must be installed in accor- dance with this section. General Instructions Avoid damage to the fusible Link Assembly during Installation by using the Frame arms only to handle the sprinkler (i.e., do not apply pressure to the fusible Link Assembly) and by using the appropriate sprinkler mrencft. Failure to do so can lead to an unstable link assembly and premature activation of the sprinkler. Damaged sprinklers must be replaced. A leak-tight 3/4 inch NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 10 to 20 lbs-ft. (13,4 to 26,8 NIT). Higher levels of torque can distort the sprinkler inlet with Consequent leakage or impairment of the sprinkler. Note: Install the Model ESFR-17 Upright Sprinkler in the Uptight posi- tion (Ref. Figure 2). Step 1. With pipe thread sealant applied, hand-tighten the sprinkler into the sprinkler fitting. Do not apply pres- sure to the Link Assembly, and handle the Model ESFR-17 Sprinkler only by the Frame arms. Step 2. Wrench-tighten the Model ESFR-17 Upright Sprinkler using only the W-Type 21 Sprinkler Wrench (Ref. Figure 2) and by fully engaging (seating) the wrench on the sprinkler wrench flats (Ref. Figure 1). Step 3. After installation, inspect the Link Assembly of each Mode) ESFft-17 Sprinkler for damage. In particular, verify that the Link Assembly and Hook are positioned as illustrated in Figure 1, and that the Link Assembly is not bent, creased, or forced out of normal position in any way. Replace damaged sprinklers. TFP3IG Page 3 of 4 WRENCH RECESS "FITTING SIDE TOWARDS SPRINKLER FITTING FIGURE 2 W-TYPE 21 SPRINKLER WRENCH TFP3I6 Page 4 of 4 Care and Maintenance TYCO Model ESFR-17 Early Suppres- sion, Fast Response 16.8K Upright Sprinklers must be maintained and ser- viced in accordance with this sections Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection system must be obtained from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing It with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Also, replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb (Ref. Installa- tion Section). The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Asso- ciation (e.g., NFPA 25), in addition to the standards of any authorities having jurisdiction. Contact the Installing con- tractor or product manufacturer with any questions. Automatic sprinkler systems are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and part number (P/N). Sprinkler Assemblies Specify: Model ESFR-17 Early Sup- pression, Fast Response 16.8K Uptight Sprinklers (TY7126), (specify tempera- ture rating), with Natural Brass finish, P/N (specify): I65-F 174'CI ..................58.447.1-165 212F )lns'C)... .............. 50-447-1.214 Special Order Sprinkler Assemblies with ISO 7-1 Thread Connection Specify: Model ESFR-17 Early Sup- pression, Fast Response 16.8K Upright Sprinklers (TY7126) with ISO 7-1 thread connection, (specify tempera- ture rating), with Natural Brass finish, P/N (specify): 165F (74C) .................. ae-440-1 -160 212F llaOCl.................so-44u.1.214 Sprinkler Wrench Specify: W-Typo 21 Sprinkler Wrench, P/N 56-001-0-686 Storage Typo NFPA FM Global Open Frame (i.e.. no Solid shelves) Single, Double, Multiple-Row. or Portable Rack Storage of Refer to NFPA 13 Chapters 16 and 17 Refer to FM Global 2-0 arid 8-9 Class l-IV and Group A or B Flashes Solid Pile or Palletized Storage of Refer to NFPA 13 Refer to FM Global Class l-IV and Group A or B Plastics Chapters 14 and 15 2-0 and 8-9 Idle Pallet Storage Refer to NFPA 13 Refer to FM Global Chapter 12 2-0. 8-9, and 8-24 Rubber Tire Storage Refer to NFPA 13 Refer to FM Global Chapter 18 2-0 and 8-3 Roll Paper Storage Refer to NFPA 13 Refer to FM Global 8-21 (Refer to the Standard) Chapter 19 Flammable/Ignitable Liquid Storage N/A Refer to FM Global 7-29 (Refer to the Standard) Aerosol Storage N/A N/A (Refer to the Standard) Automotive Components in Portable Racks N/A N/A (Control mode only; refer to the Standard) N,A-riolueplicubla TABLE A MODEL ESFR-17 UPRIGHT SPRINKLER COMMODITY SELECTIONAND DESIGN CRITERIA OVERVIEW GLOBAL HEADQUARTERS 11400 Pensibrook Parkway, Lansdale, PA 194481 Telephone +1-215-362-0700 Copyright C 2015 fy00 Fire Prodacts, LP. All rights reserved. tyco IPJC060L end MONEL ore n rk Of 500,na Spools1 Metals Carperutlon. Fj P,Ovr'.v,P,odvcrs TEFl.ON Is trodans,1, of in, Dupont Corpona500. Viking Technical Data may be found on The Viking Corporation's Web site at http:1/www,vlklnggroupinc.com. The Web site may include a more recent Frame Casting: Brass UNS-C84400 revision of this Technical Data Page. Deflector: Copper UNS-C19500 Bulb; Glass, nominal 5 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly; Copper UNS-C11000 and Stainless Steel UNS-530400 For Polyester Coaled Sprinklers: Belleville Spring-Exposed For ENT Qgted..SPitl6(si Belleville Spring - Exposed, Screw and Pipcap - ENT plated. I-/Not for FM Approval. ordering Information: (Also refer to the current Viking price list.) Order Micromabce and MicromaticHP° Standard Response Upright Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffixes: Brass =A Chrome = F, White Polyester = Put-lW, Black Polyester = M-/B, Wax Coated = C, Wax Over Polyester = V-/W. ENT = JN Specifications: Minimum Operating Pressure: 7 psi (0.5 bar)t Maximum Working Pressure: 175 psi (12 bar) wwp Factory tested hydrostatic rating: 500 psi (34.5 bar) Thread size: 1/2' NPT, 15 mm BSP, 314' NPT, 20 mm BSP Nominal K-Factor: 8.0 U.S. (115.2 metric") Glass-bulb fluid temperature rating: -65 'F (-55 'C) Overall Length; 2-3/8' (60 mm) t cULus Listing. FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure br LPCB and CE Approvals ONLY 1s5 psi (0.35 bar). -. Metric K-factor measurement shown is In Bar. When pressure Is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards: Pagel of 6 MICROMATIC°STANDARD I TECHNICAL RESPONSE UPRIGHT JII(JI's1Gi® SPRINKLER VK200 (K8.0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Micromatic° Standard Response Upright VK200 Sprinkler is a small, thermo- sensitive, glass-bulb spray sprinkler available in several different finishes, temperature rat- ings, and K-Factors to meet design requirements. The special Polyester and Electroless Nickel PTFE (ENT) coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts. (Note: FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classification for Polyester coating as corrosion resistant.) Viking standard response sprinklers may be ordered and/or used as open sprinklers (glass bulb and pip cap assembly removed) on deluge systems. Refer to Ordering instructIons. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class Series 2000 VdS Approved: Certificates G414013 and G414014 LPCB Approved CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-0021 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and UL Design Criteria on page 4 cULus Listing requirements, and refer to Approval Chart 2 and FM Design Criteria on page 5 for FM Approval requirements that must be followed. 3. TECHNICAL DATA Page 2 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@viklngcorp.com Temperature Suffixes; 135 'F(57 'C)A, 155 'F(68 'C)= B. 175 'F (79 'C)= D. 200 'F (93 'C)= 0,212 'F (100 'C)= M. 286 'F (141 'C) = G. 360 'F (162 'C) = I-I, 500 'F (260 'C) = L, OPEN = Z (PTFE only). For example, sprinkler VK200 with a 1/2' thread, Brass finish and a 155 'F (68 'C) temperature rating = Part No. 18268A8 Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the 'Sprinkler Accessories' section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 10896W/B (available since 2000). D. Wrench for Wax Coated Sprinklers: Part No. 13577W/B' (available since 2006) A 'I,' ratchet is required (not available from Viking). Sprinkler Cabinets: Six-head capacity: Part No. 01724A (available since 1971) Twelvehead capacity: Part No. 01725A (available since 1971) INSTALLATION Refer to appropriate NFPA Installation Standards. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. AVAILABILITY The Viking Micromalic° Standard Response Upright Sprinkler VK200 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Form No. F_032814 16.03.04 Rev 16.1 Replaces Form No. F032814 Rev 15.1 (Removed Black PTFE) I Form No. F_032814 16.03.04 Rev 16.1 Page 3 of 6 Page 4 of 6 N I KINGI 9 MICROMATIC® STANDARD RESPONSE UPRIGHT SPRINKLER VK200 (K8,0) N II(J141Gi MICROMATIC5 STANDARD RESPONSE UPRIGHT I SPRINKLER VK200 (K8,0) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 'ral,'nhnnn' 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp.com TABLE 1: AVAILABLE $PRINKLER TEMPERATURE Sninkler Temperature Sprinkler Nominii RATINGS AND FINISHES Maximum Ambient -Bulb Color - Classification TempetatUre Rating5 Ceiling TemperatUre Ordinary 135°F (57 'C) 100 'F (38 'C) Orange Ordinary 155°F (68 °C) 100 'F (38 'C) Red Intermediate 175 'F (79 'C) 150 'F (65 °C) Yellow Intermediate 200 ¶ (93 'C) 150 'F (65 'C) Green High 286 °F (141 'C) 225 'F (107 °C) Blue Extra High 360 'F (182 'C) 300 'F (149 'C) Mauve Ultra High' 500 °F (260 'C) 465 'F (240 °C) Black Sprinkler Finishes: Brass, Chrome, White Polyester, Black Polyester, and ENT Corrosion-Resistant Coatings': White and Black Polyester in all temperature ratings. ENT in all temperature ratings except 135 °F (57 'C). Wax-Coated Brass and Wax over Polyester5 for sprinklers with the following temperature ratings: 155°F (68 'C) Lt. Brown Wax 175 'F (79°C) Brown Wax 200 ¶ (93°C) Brown Wax 286°F (141 'C) Ok, Brown Wax5 Footnotes The sprinkler temperature rating is stamped on the deflector. - Based on NFPA-1 3. Other limits may apply, depending on tire loading, sprinkler location, and ether requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 'F 'C), 300 OF (148 'C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 (149 response time may be severely retarded. The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, cerity, through the end-user that the coatings are compat- ible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT. For ENT coated automatic sprinklers. the waterway is coated. Wax melting point is 170 'F (76 'C) for 286 OF (141 'C) temperature rated sprinklers. Protective Sprinkler Cap'—...,,. Wrench Flat AVFP- jw~~~ Figure 1: Standard Sprinkler Wrench 10896W1B Form No. P032814 16.03.04 Rev 16.1 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp,com Approval Chart I tdO KEY Mlcromattcu Snandard Re puitse Upright Cprinklor Maxim 175 PSI (12 bar) WWP Sprinkler Thread Size Nominal K-Factor Overall Length Listings and Approvals' Base Part SIN (Refer also to UL Design Criteria.) Number' NPT BSP U.S. metric' Inches I mm cULus' j VdS I LPCB j Standard Orifice 182680 VK200 1/2' 15 mm 8.0 115.2 2-114' 57 Al, 84. CS, 03, E6 .42 B4 F3 - 18263 VK200 3/4' 20 mm 8.0 115.2 2-1/4' 57 Al, B4, CS. 03,06 .42 B4 JAL2, F3 - 18266 VK200 - 20 mm 8.0 115.2 2-1/4' 57 Al, 84. CS, D3, E6 .42 B4 P3 - 57 Al, 84, CS, 03, E6 Pr2 A2. B4 F3 F3 102200 VK200 112' 15 mm 8.0 115.2 2-1/4' 10141 VK200 3/4° 20 mm 6.0 115.2 2-1/4" 57 Al, 84, CS, 03, E6 .42 A2, B4 F3 P3 10169 VK200 - 20 mm 8.0 115.2 2-1/4' 57 Al, 84, C5, 03, E6 A2 A2, 64 P3 P3 Approved Temperature Ratings A- 135°F ),57 'C), 155 'F (68 'C), 175°F (79 'C), 250 'F (93 C). 286 'F (141 'C). and 360 'F (182 Approved Finishes C) 1 - Brass, Chrome, White Polyestet'° and Black Polyester- 155 'F (68 'C). 175 'F (79 'C), and 200'F>(93'C) 2- Brass, Chrome, White Polyester, and Black Polyestei° C -286 'F (141 'C) - Brass and Chrome D - 500 (260 'C)° 4 - Wax-Coated Brass and Wax Over Polyester' E - 155 'F (68 'C), 175 'F (79 'C), 'F (93 5-High Temperature 200 ¶ (93 C) Wan Coating (corrosion resistant); maximum ambient tern- ye ceiling 'C), 'C), 'F 286'F (141 360'F)152'C), and 500 (260 'C)' 6- tiNT' F -155 'F (68 'C). 175 'F(79 'C), 200 'F (93 'C), 286 'F(141 'C), and 360'F (182 'C) Footnotes I Base part number is shown. For complete part number, refer to Viking's correct price schedule. ° Metric K-factor shown is for use when pressure is measured in bar. St/hex pressure is measured in kPa, diode the metric K-factor shown by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 'Listed by Underwriters Laboratories Inc. for use in the U.S. and Canada. ° cULus Listed as corrosion resistant ° Other colors are available on request with the same Listings and Approvals as the standard colors. ° Sprinklers of Ultra-High temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 'F (149 'C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 'F (149 'Cl, the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 'CE Certified, Standard EN 12259-1. EC-certificate of conformity 0786-CPD-40137, 0786-CPD-40142, 0786-CPO-40177, 0786-CPD-40182. 0832- CPD-0021. and 0832-CPO-2003. °The 1/2' NPT Large Orifice Sprinkler is listed and appmxed for retrofit only when installed in accordance with NFPA 13. MED Certified, Standard EN 12259-1, EC-certificate of conformity 0832-futED-1003 and 0832-MED-1008. °'bESlGNCRrTERlAUL w1soiefrirtoAppronolClia1l) CIJLUS Listing Ronuirenfents: The Viking Micromabc° Standard Response Upright Sprinkler VK200 is cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. - Designed for use In Light. Ordinary, and Extra Hazard occupancies. - The sprinkler installation roles contained in NFPA 13 for standard spray upright sprinklers mast be followed. IMPORTANT: Always refer to Bulletin Form No, F091699 -Care and Handling of Sprinklers. Also refer to page F_080614 for general care, installation, and maintenance infor_mation. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Form No. F_032814 16.03.04 Rev 16.1 Page 5 of 6 MICROMATIC° STANDARD NIKJW*i TECHNICAL DATA RESPONSE UPRIGHT SPRINKLER VK200 (K8.0) I- I The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikingcorp,com 1 00 rt 2 (FM) Mlcromat(c° Standard Response Upright .Sprinklel's Maxlmum175PSl(l2bar)%W.)P A1XaEllrpekrda) Sprinkler Base Thread Size Nominal K-Factor Overall Length J FM Approvals' Part Number' SIN (Refer also to DesIgn Criteria below.) NPT j BSP U.S. metric' Inches torn Standard Orifice 18268' VK200 j 1/2" 15 mm 8.0 115.2 2-1/4' 57 Al. B2, Cl, 03 18263 VK200 3/4" 20 mm 8.0 115.2 2-114' 57 Al, 82, Cl. 03 18266 VK200 -- 20 mm 8.0 115.2 2-1/4' 57 Al, B2, Cl, 03 VK200 10220' 1/2' 1 m 2-1/4" 57 Al, 02, Cl, 03 10141 VK200 3/4' 20mm 8.0f115.2 8.015.2 2-1/4' 57 Al, 82, Cl, 03 10169 VK200 - 20mm 8.015.2 2-1/4' - 57 Al, B2, Cl, 03 Approved Temperature Ratings A-135'F(57'C), 155'F(68'C), 175'F)79'C),200'F)93'C). 286 'F )141 'C), and 360 'F (182 'C) Approved Finishes B - 135 'F (57 'C). 155 'F (68 'C). 175 'F (79 'C), and 1 - Brass, Chrome, White Polyester', and Black Polyester' 200 'F )93 'C) 2- Wax-Coated Brass (corrosion resistant) C-500'F(260'C)' 3-EN)' 0-155 'F )68 'C), 175 'F )79 'C). 200 'F (93 'C). 286 'F )141 'C), 360 'F (182'C), and 500'F /260 Footnotes Base part number is shown. For complete part number, refer to Viking's current price schedule. 'Metric K-factor shown is for use when pressure is measured in bar. When pressure is measured in kPa, divide the metric K-factor shows by 10.0. This table shows the listings and approvals available at the time of printing. Check with the manufacturer for any additional approvals. 'Other colors are available on request with the same Approvals as the standard colors. 'Sprinklers of Ultra-Nigh temperature rating are intended for use inside ovens, dryers, or similar enclosures with normal operating temperatures above 300 'F )149 'C). Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 'F (149 'C). the response time of the Ultra-High temperature rated sprinkler may be severely retarded. 'FM approved as corrosion resistant. 'The 1/2" NFl Large Orifice Sprinkler is listed and approved to, retrofit only when installed in accordance with NFPA 13. , . -. , . rDESIGN CRITERIA - FM (Also refer to Approva/ Charl2.) FM Approval Requirements: The Viking Micromatic° Standard Response Upright Sprinkler VK200 is is FM Approved as standard response Non-Storage upright sprinkler an indicated in the FM Approval Guide. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, coiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the coiling. NOTE'. The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page F_080614 for general care, Installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organiza' (ions, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Page 6 of 6 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcsvikIngcorp,com Sprinkler wrench 13577W/B" must be used for Installing wax coated sprinklers. Step I: Carefully slide the wrench sideways around the deflector, ensuring engage- ment with the spr)nklger wrench flats. Wax Coated Upright Sprinkler "A 1/2" ratchet Is required Stop 2: Carefully press the wrench downward (not available from Viking) and ensure engagement with the sprinkler wrench flats. Figure 2: Wrench 13577W/B for Wax Coated Sprinklers Form No. F032814 16.03.04 Rev 16,1 1 Form No. F_032814 16.03.04 Rev 16.1 Replaces Form No. F_032814 Rev 15.1 (Removed Black PTFE) The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems in commercial and residential construction, Bull Moose Tube has added Eddy Flow to its comprehensive line of sprinkler pipe products. Eddy Flow is a specially engineered replacement for schedule 10, offering better flow characteristics while providing design flexibility. This product is FM approved, as well as UL listed (for U.S. and Canada) for roll grooving and welding for use in fire protection COMPARISON systems with a working pressure of 300 psi or less. Please check with appropriate sources for up-to-date listings and approval information, As an added benefit, it is more economical to use than schedule 10 due to reduced delivery costs and ease of handling. Furthermore, Eddy Flow's larger ID provides an opportunity for downsizing and further cost savings. Ul- ON p,~, 11/4 1.660 1.530 1,442 11/2 1.900 1.728 1.682 2 2.375 2.203 2.157 2 1/2 2.875 2.705 2.635 3 3.500 3.334 3.260 4 4.500 4.310 4.260 * Corrosion Resistance Ratio i :- 1.380 1.98 1.00 1.610 3.44 1.00 2.067 2.78 1.00 2.469 1.66 1.00 3.068 1.00 1.00 4.026 1.00 1.00 Dual Certified to ASTM 4135 and A795, FM Approved for roll grooved, and welded, and plain-end application in wet systems. UL Listed (for U.S. and Canada) for joining by welding or by listed rubber gasketed fittings for use in wet, dry, preaction, and deluge type sprinkler systems. UL Listed (for US and Canada) and FM Approved for use with Victaulic® Fl1 Fittings in plain end applications. Lightweight. saves shipping costs, and offers easier handling. Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. Floor stock available in various lengths produced in Casa Grande (AZ), Gerald (MO), and Masury (OH). Also can be ordered in custom lengths.. Can be used for wet and dry* systems. UVY r-,uvv uca, £Jo ,,,Jl tJIi./R'I QIVWtttV IV rrtaer r-tvis requirement tar cry systems. PIPE PREPARATION For proper operation, all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint, scale, dirt, chips, grease, and rust must be removed prior to installation, Failure to take these important steps may result in improper coupling assembly, causing leakage. Also, check the manufacturer's instructions for the specific fitting used. - 1819 Clarkson Road For additional information, c®us Chesterfield, MO 63017 contact your salesperson today at BULL INACIOSE CQNY LISTED (800) 325-4467 (800) 325-4467 or (636) 537-2600 FAX: (636) 537-2645 in the USA, or from Canada _______ www. bu I Irnoosetube. corn call (800) 882-4666 ACÜ company moosetu corn APPROVED All information contained herein is accurate as known at the time of publication. Butt Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 A Lightweight Schedule 40 Replacement Pipe That Has a Corrosion Resistance Ratio of 1.0 Bull Moose Tube Company has been making pipe for a long time and is recognized as a producer of quality pipe products. Eddythread 40 is designed with the same thoroughness as our other fine pipe products and now our customers have an option to buy a carefully designed replacement for Schedule 40 that: Has a Corrosion Resistance Ratio of 1.0 Has a Pressure Rating of 300 psi Is Lighter Weight Than Schedule 40 Is Approved by Factory Mutual and Listed by Underwriters Laboratories Is Produced in Accordance to ASTM A-135 and A-795 Can be Used With Standard Schedule 40 Threaded Fittings, Couplings and Valves Is Produced From Steel With Excellent Properties of Strength and Threadability Can be Used in Wet, Dry, Preaction, and Deluge Type Sprinkler Systems* Offers Lower Freight Costs EDDYTHREAD 40 SPECIFICATIONS 1 1.461 1.083 70 11/4 2.070 1.418 51 11/2 2.547 1.654 44 2 3.308 2.123 30 CORROSION RESISTANCE RATIOS 1 1.00 1.00 11/4 1.00 1.00 11/2 1.00 1.00 2 1.00 1.00 * Eddythread 40 can be hot dipped galvanized to meet FM's requirement for dry systems 1819 Clarkson Road For additional information, Chesterfield, MO 63017 contact your salesperson today at c&L us 3 e lax (800) 325-4467 (800) 325-4467 or (636) 537-2600 LISTED BU MOD COMPANY FAX: (636) 537-2645 in the USA, or from Canada _______ \VWW, bull moosetube.com call (800) 882-4666 A CRJ company e-mail:@illmoosetube.coii APPROVED All information contained herein is accurate as known at the time of publication, Bull Moose Tube reserves the right to change product specifications without notice and without incurring obligation. 8/08 General Description - Sex Fire PmtenSen Subnnrttte Street tan Pressure Raring and LislingtiArnprunaf tnlormahan TheAgum772R:gpeheroarklbyrthy Orndygiprg along Ore crrtarerfrewrce of the pipe grosses Thgd rouptings are pInIoned for thy pipe and lrreaxuppidaGnnx: Figure 772 Rigid Cexpfngs area proven dependable nre0etd of joiningpipe and arnaxec000nniadalxeahaetvxeldthg.onreadeoon using flanges. Iteof pressures upto5Wpoig (3447 Wa) depending OC pipesizeahe rivafltlriduress when used iv fire protection nmrrices. Rigid Cwap9egsare recommended toedrypipe and treeeeeapp5eationx: W4ID1t The lfgore 272 Rigid Courphrtg described hervin ar0/1heairdrrnaiv0rcumptiaomainh ftsdincurnent o/OfreNahoxl&eProrerjinoAxsodntioe,i,addiriorr to Ore ufaodavis of any other anitroritIcs hasting irriddlidrri tailwe to rita so may impair the p eOn rrreanco of lutz doe/nw The owner is rogtmsrhe Porrnaiirlainirg 66, fire mvt System and devices it proper, operating eetrfliicon. The ix65ding c000actnr or splielder estuuWhenra/rnuklbecxntad,&e/lhanyqtovtiees Technical Data Figure: 772 Stoex:1W-12 Approvals: UL. FM. ULC. VdS. and LPCR: See Are Protection Submittal Sheet for erect Listing/Approval information. Hotwiop Ductile iron conforming to OSTSA 0-536, Grade 65-45-t2 Protncpee Coallegor Non-lead orange paint Fire brigade red (optional) non-lead paint Hot dipped galvanized conforming to ASTht 0-153 Rotl/Nrrto: Track Head Bolts - conforming to /STM 0-153, Zinc Plated, (Min. loosed = 110,000 psi/758,422 kPa) Meted - conforming to aSltd F568M Gasket (specify when ordering) - Grade A" EPOMA violet color code ambient to vi5OrF (.6WC) lath reprntection systems. Not recommended for lot water syslems. Tri-seal(500eEEPOM),gneoncolororde for use in dry pipe on freezer systems. pretubricated (Grade "K EPOMA) (Son Data Sheet 17101895 for aid In selecting proper packet) Ordering Procedure When placing an Order, indicate the frill product earle. Pleosespecilythe quantity, figure number. type of gasket, Grade 0 EPG95S, Prdubtfcoted (DradeKEPDhtA)orDradeng EPBMTri-Seai, and see. GrireredGrenzhePlpirgptododosdsets,acownoeies and other products am available throughout 810 US.,ar.adm and iifornrabonady,thmogfranetwork ofdtiha80oncoetestlecnroywdtedirediporcoo 215-362-0700 for the distributor nearest you. Care and Maintenance The owner is responsible for the inspection, tenting, and maintenance of their Ore protection system and devices in accordance with the apablectaheardsolthehabgea Fire Protection Association (e.g.. NAPA 25), in addition On the standards of any 009lOnify Easing jurisdiction. The rtrstalhrgconteactororpreduct maeutactorer Page 1 of 2 July 2004 tqco/ Fire & Building Products Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 www.tyco-fire.com Grinnell Grooved Fire Protection Products Figure 772 Rigid Coupling - Patented should be contacted relative to any questions. Any impairment most De immediately corrected. It is recommended that automatic sprinkler systems be inspected, hashed. and maintained by a qualified Inspection Serraco. Limited Warranty Predicts nonvlacbirot by lyre Ann Pnotacts are onnaothesufetyte000rip/edpnyenfecleer(lg)ymrs agai1stdefecS'wnmtmtoarniwodunranrniopmlmrwi1 lorardpropertybsabsandttnidaeheuederttcrrnnai lceaherersndltrkv.urantymdwqinrntwt(lg)yrots from date of daitmort by lyre Are Products. No warranty is given for products or components nronufocturhebjconrparhenotatteatedbyo.snerslrpi erdhlyrethmPredocteentnrpmdvdeaheaxnrymromds eih65haadwersstApttvroisuzinrpeeri35tlaijon nsnn,orn4nio1ha,eeetbeeei35ged,eratirtared, nloiteed or repaired in accordance with ayp65bfl Standards of Me 00501W fire Protndcei Asoreintiori WA) ,58/oromoanrdardsnf any othoWnlmnties Racing .Iaredioiorr. Materials found by 1pm Fin Prhersts to be detect/nO shag be tither repaired on replavat,atlycoFoePmdiRE'scdeopbrr. Tre Ann Prhecchwiherowxnes,eccaidbol/tuszrypmsorr toavanrretnroanyeOtmob9gabrorfremo60tiewgr the tote of products or pads of products. 7100 Are Pradida shad not be rcspmhablo 9ar5pi1n0ensys1orn design ornasoriramsra5or incomplete hntornnajed rapptwtby Buyer orBuyer's pprmeudAses. IN NO P/Bet S14011 V/CO FIRE PRCLt&ICtS 00 UO&E tNO3d11100T, TORT, STHOOTUa810YOR IN0lRE(,7,pp96tO.LORCOt06Th960tbOL0ZMO 093325196 8131 f&1TU0ltltETOtfi89R Tht0R00S, RgG#gol,ESSOFWI/Ottgagl'dXiRAEPActOUCtS WAS EFORM80OBIYJTIhEP(,pmELJTYOSSh54 0/0001365,000 IN NO 60090 SHALL 1/tat 950 PAOShEta'UO8GJ1Yp7Jpj93Lod1E0UoL 10ThESgL00pAl Page aura npPneso Figure 772 Grooved Coupling 0 1 1 A PC - Mavirnuer avai80e gap between pipe ends. Mirrirrooe gap = 0. I Madrrrum pressure and end toad are total from all foods based no standard weight steel pipe. Pressure rulings and end toads rnwy deter on enter pipe rrrarnriaiu audrur wait ttaolornss. Connect Tyeo Fine Peoduots for details. See Fire PrurontiOn Equipment Submittal Shoot for Listing and ApprOver pressure ratings. -- Gold voter coded metric boll sizes are available open request Mao End Gap to for 04 greened standard weight prptz values ire roll grownnd pipe edIt be Yr that of out grooved. Figure 772 R5-dcoopliogshamaoa.rh-000hoe Feature of 'gripping; teett7 along ttto 000plhtg Eons in sizes tad -4'. etrinre retake he Fig.. 772 perfectly Suited or 'Son over irwtaoab000 where the likelihood of wlabo.r in greatest This feature may ebrerorate tIre need 01 nrrtru hangers en support the eon over due to h,anaond rigidity and gripping tnrwn saving tiwe and cost. General Notes: iris the Designer's responsdiuity to owed products suitable for the intended seer/no and to eosare ISO that prowure ratings and perlorrnaooe data 0 not exceeded, always read and understand Ore installation 9001 knstrvvtioeo (tH-n900), Nnvor remtraee any pipirrp eumpanetet or nwnoor or modify any prodeg dehdneotes otewrd 6rstdnpressoriniog and druusnrg One sysreat. Material and gasket selection strnr.dd rIo noised to be wnmpahfen tue Ore specific application. Certified Company TYCO FIRE PRODUCTS. 451 North CaotneoAneeun, Laondale, Pennsylvania 19960 Printed USA, c 75 h Pipe Mao;* End Gap Max:t Pressure Mau.T End Load Nominal Dimensions Net C.D. A B C Size toctmes Inches psi Lbs. inches In s' -- es inches - Lbs. mm mm kpa N mm mm Ota, 0 Lg. Kg. 1r4 1.660 0.06 300 649 375 4.38 1.81 Wo2'/ 1.0 42.4 t.5 2068 2,807 69.9 011.3 46.0 M10x57 0.5 1.900 0.08 000 1,417 3.00 4,62 1.81 e/e•02r/•• i.e .08.3 2.0 3,4d7 6,303 76.2 t17.3 46.0 Mt0o57 0.5 2' 2.375 0.13 500 2,214 3,41 5.12 1.88 o%r4• 1,5 60.3 3.3 3,447 8,848 86.6 130.0 47.8 Mt0o57 0.7 2.4- 2,874 0,13 500 3244 3,91 5.63 1.88 WOo 2, /' W 2.5 73.0 3.3 3,447 t4,430 99.3 143.0 47,8 Mt0e57 t.t 76.1, 3.600 0,13 300 2.129 4.19 5.72 2.00 M10057 2,6 76.1 3.3 2,068 9.430 106.4 145.3 50.8 1.2 3.500 0.13 500 4,808 4,63 6,26 1.88 Wo2W 2.6 85.8 3,3 3,447 21,387 117.6 158.8 47.8 M10ir57 1.2 4.500 0.19 500 7,948 5.81 7.50 1.97 W02'/7 3.5 t14.3 4.0 3,447 35,353 147.8 1905 50.0 M10z57 1.6 1397 5.500 0.19 300 7,127 7.02 9.72 2.06 Ml6o83 139.7 4.9 2,068 31,701 178.3 246.9 52.3 34 5.503 0.10 300 7,288 7.09 9,71 2.04 ha' 355' 7.5 141.3 4.8 2,068 32,417 180.1 246.6 51,8 Mt6ze83 3.4 165.1, 6.500 0.19 300 9,950 0,09 10.53 2,13 P416083 7.6 165.1 4.8 2,008 44,258 205.5 267.5 54,1 3.4 6.625 0.19 400 13,782 8.09 10.53 2,13 n/e03r27 7.6 168.3 4.8 2,758 61.302 205.5 267.5 54,1 Mt6x83 3.4 8' 8.625 0.19 450 26278 10,56 13.56 2.62 Wn4t/a 18.0 218.1 4.8 3.103 116,885 268.2 344,4 66.0 M20 0 121 8.2 to- 10.750 0,13 250 22.679 12,84 16.41 2.62 Vx6½' 24.6 273.0 3.3 1,724 100,876 3261 416.8 66.5 M24ie 168 11.2 02' 12.750 0.13 250 31,903 15,41 18.84 2,62 1x6W 42.0 323.9 3,3 1,724 141.905 391.4 478.5 66.5 M2dx165 19.1 Techni l Semvnces: Tel: (800) 381-9312/ Fan: (800) 701-5500 www.tycn.tirn.com Grinnell Grooved Fire Protection Products Grooved Fittings General Malenal Limited Cast lRgUres:201,210,219,250,260,501, 510, Description 519, 5100E. SWS. biOS and 519S - Warranty See Ore Pretension 0tde iron conforming to ASSISt A-536. piodaCO manufactured by Tyco Fire Products are Ssbrnittsl Sheet or Smile 65-45-12 warranted solely to the original Buyer for lee (10) Pressure Oaring and Fabricated Steel: Figures 391. 392. 393, 312. ysagairoodefectsbreralerizlandwodnnarohip Llsting/epprounl 313, 321,327. 341 and 350- Carbon Steel. when paid loraodptopodyirsoallcrf and maintained (Sizes 9'- iz are Schedule 30). eepimlen(1O)yslmredeoeotsirige-cetbyTyuc Information (Sizes 1/ - 6ar0 Schedule 40); under normal use and service. This warroely wlll cenformmg to ASThI 4-53 Grade 9 Fire Prerlucts. theranetyis given for prodimaor The gmevedfiftiogs provide aneconoioteal Protective Coatings: components reanutactureng by companies not and etlliaenlerethudulchangergdirnetion, - Non-lead orange paint affiliated byisrripssimTymFirormaucroortot adding an outlet, reducing, or capping -Fire brigade rod (optional) nun-lead paint pmdesm wtucb masohject grooved piping systems. Grooved fittings - Hut dipped galvanized conforming to ASTM tomisese,irnptopeeinstathtion,cennsien,orsviricle are available in durable ductile iron or 0-153 have not been irtstalled, maintained. mudded or fabricated steel as mtdroated. iondina ir,5pfiUAle553thmag indicated- Not Figure 5195 and GigS fittings are Ordering Fire Protection Association (NEPA). special sheet eadlas littiegs with smaller center In end dimensions than standard Procedure aud/orthe standards olarryotherAuthonliesHamang Jurisdiction. Materials toumidhyTynu Fire Products grooved fittings. Depending on the sloe and When placing an order, indicate the toll product tubedelnctiveshailheeitlmeerepairedomreplacoij,at coupling used.lhere maybe interferences at nante,Please npecigythe quantity. rigumnumber, Tyrn Pre Products'soleoptiori. Tyco Fire Products the bull pads that require reposilieniugulthe wall thickness, and size neither assumes. nor authorizes any pecan to coupling erleelatlon. The use of flange Grinnell Grooved Piping Products, names, assureretoritaoyutheroblipahoninrovmrectioni-iith adapters is not recommended with Figures accessories and other products are available Umesale olprodirolsorparrsufproducts. Tycu Fire 510S and 519S fittings. Contact Tgeer Fire thm000haatthela.S.,Canada,aedinternationally. Prodxbshatmtberespeenlblelorsprhrktersystoor Peodocls for details. thiuegli a network 01 distribution centers. You designrmrnrserircucurateorkanniyletebrtonrgbon WARNING ongm write directly or call 215-362-0700 for the suppled by Buyer or Buyers representatives. The Fittings described herein macthe installed distributor nearest you. IN NO EVENT SHALL TYCO ROE P000001096 avdmainoiovdincornplivvceerithouisdocewen7. LIABLE. IN CONTRACT, TORT. STRICT UAtlLPtY as snuas with the applicable standards of tire Care and 09 UNDER 5101 OTHER LEGAL THEORY. FOR INCIDENTAL INDIRECT. SPECIAL OR National Are Protection Association inadd,50v Maintenance CONDEQUELDSIS%flGESIInCWOIM3BUTEGT to the standards of any other authorities han/vp Jurisdiction. Failure bode so may impair the The owner is responsible for the inspection, LIMITED TO LABOR CHARGES. REGARDLESS OF gaertwreairce of this device. testing, and maintenance of their fire protection VllHEtH001'iWAREPRODIJCTSWOSINFORMCO The pence is responsible for maintaining their system and devices in accordance with the ABOUT THE POSSIBILITY III SUCH DAMAGES. fire protection system and devices in proper applesblestandards otthe National FimPmaicban AND INNOEVENTSHALL TYCO FIRE PRODIJCTS' opcaabvgcunditiorr The instathvgconuacloror Association (e.g., NFPA 25), in addition On the LIABILITY EXCEED MI AMOUNT EQUAL TO THE sprivtoerneanutacouwrshoajdueccntactecte'injt standards of any authority having jurisdiction. SALES PRICE. anyquestromts. moinntatlingcontroctoror product roanufacourer 7)fP6f0008#G WVtARTYISJR4OEP11.4EUOE should be contacted relative to any questions. ,NTAALL O73 WAJ60.4fffOES LlR Technical Any impairment must be immediately corrected. IMPLIED. INCLUPIliG WARRANTIES OF It is recommended that automatic sprinlder MERCH,AMI'ABIW'Y AND FPwESS FUR A Data systems be impeded, tested, and maintained by PAR1RL4RF) Approvals' a qualified Inspection Service. UL FM. ULC. Vd5, unit LPCD: Note: See Fire Protection Submittal Sheet for enact Listing /itpproual information. Page 1 of 6 September 2004 TFP18I0 ca Page 2u16 Tr'plure Figures 201, 210, 219, and 260 ' r Figure 201 Figure 210 eec-f r Ploare 260 Figure 218 OSa, reauro. e .e-,,0i,,,a.ope,a no u.,,,,eu,,rty,,e AOL re!oaroagreootuendrw.u,eee.aiureotbce.ngur4og one Oneun w,. rec,ein 6. e' - mF rOs no none, eeoc,, ,cuero,rr me, LU ace,., rcd eec reerei nee,eusreS Fire & Building tLICD/Products Friction Resistance' (gg51nsnd as Size 900 400 Branch Run Inches Feel Feet Feel Feet mm Meters Mrreis Uelens MeterS g- 4Z4 0.6 0.6 0.3 1.5 0.6 "TW" 2.3 1,2 5.8 2.3 48.3 0.7 0.4 1.8 0.7 2 3.2 1.6 0.0 3,2 60.3 1.0 0.5 2.5 1.0 "SW" 3.9 2.0 9.8 3.9 73.0 1.2 0.6 3.0 1.2 4.1 2.1 rn.3 4.1 Equiv 10 33 133.0- 4.6 alent Straight Pipe) 76.1,,,, 12 0.6 3.1 1.2 -3- , _73 c 08.0 1.5 0.7 3.7 1,8 g'S TB rou.o,0 2.0 1.0 so so -4-- - 3'S 00T 1 - 143 2.0 1.0 5.0 50 Sd Il 6.0 24 8.0 4. 25.0 8.0 139.7. 2.4 1.3 6.1 24 5 02 4.1 20,5 82 1 41.3 su 1.3 6.3 55 3 .8 9.0 59 1.4 7.2 59 r 165.1,., 29 1.4 72 59 159.0- 2 9.5 9.9 5.0 W 1603 3.0 1.5 7.6 3.0 101 13,1 216.3.,. 4.0 20 10.0 4.0 219.1 13- ST 228 1.3.1- 40 2.0 10.0 4.0 tO 16$ 0.3 01,3 16,5 273.0 5.0 25 12.6 5.0 t2 19.9 9.9 49.7 19,9 323.4 6.i 3.0 15.1 6.1 Figure 20t FIgure 210 Figure 2602 05' Etbnss Fi Nominal gure 219 00. Elbncn Ten Erei Cap Cents Inches Incises LppO.6e, CALC ST 9L Lbs. 50T EWE 500 me çg mm jg mm me inclm00 Lbs. InvIres L . TSS' n.n 32ST 's:sg' 1.4 0.08 0.4 44.5 04 09.9 0.5 69.0 0.6 22.4 0.2 b 1.0 2.7 1 V-11 1.75 m.1 r.0 0.88 0- 44.5 0.5 69.0 0.5 69.9 0.0 22.4 0.3 2. 1.8 2-0 0-9 - 'SSt SSW 'SSW '3TY 'SW 50.8 0.8 82.6 0.9 82.6 1.2 22.4 0.4 -;:- 'S'S ST 'S'S 'SSt 2 57.2 1.0 95.3 1.4 95.3 2.8 224 0.4 - 'S'S 5 'S u,nu 76.lww 57.2 1.0 90.3 1.4 05.3 2.6 23.9 0.5 -:- 0E. SW 'S 63.5 1.6 100.0 2.0 108.0 3,2 22.4 0.5 tno.nww 73.0 25 120.7 3.9 120,7 5.2 - - 'S ST &rs SI3 - - 5.8 413 4-5 7.0 131, S. 26.0 365 buu s 3,00 52 5.00 8$ 5,00 lt,8 tOO 2,6 76.2 2.4 127.0 3.9 127.0 5.4 25,4 1.2 820 3.5 t33.4 5.t 133.4 4.0 - - 325 773' 5135" 11,3 5135 "i5'4- - - 355 'T sso 11,3 sog '13-' 'oUi sr rem 52.6 3.5 139.7 5.1 139,7 6.9 214 2.1 - 'SSW 'S '13- s$n '15 ISW 5.0 02.6 3.9 138.7 6.1 039.7 7.7 25,4 2.3 135' 10 53- '13- 6,00 '1 - 159.0mm 08.9 5.4 152.4 6.6 052.4 6.3 - - 135' '13- 03- '13- un,u T 3- 165.lremn 8.0.9 9.4 165.1 8.4 165.1 11.8 25.4 3.4 _113_ 13ST '13- 5'3- 135' 73- 6' 88,9 5.4 165.1 8.4 165.1 tt.0 25.4 3.4 0.25 23.0 7,75 30.5 7,75 45.0 O,3rnar 108.0 10.4 196.9 tEA 196.9 20.4 - - 3- 315 '13ST '13- 45,0 AL 0' 100.8 10.4 196,9 16.6 196.9 20.4 30.2 5.8 m_ 13ti 939" 13- 122.7 114.71 14,1 228,6 27.2 228.6 32.7 31.0 9.1 - 33- 103- E3- 10356533- i2 t33.4 I0.t 254,0 30.4 254.0 42.0 3t.8 06.3 Page 3o16 lFP1810 Figures 501, 510, 519 -and 5IODE Flgcro 501 FIgure 510 FIgure 519 Figore 5100E Figures 501S, 510S and 519S F/gore 501S Figure 5105° Figure 51957 Flgu,e501S Figure 510S Flgure5l9S 45° Elbow 90° Elbow Ten dm6 Inc/ins Lbs. Inches Lbs. Inches Lbs. AAA j9 mm mm 21 S® 12 2.75 1.5 2.75 2.1 50.8 0.8 65.9 0.7 69.9 1.8 3.2 2'/ 2.25 22 3.00 22 3.00 3.0 572 1.0 1.5 76.2 1.0 762 1.4 3.9 76.1- 3.00 2.3 3.00 -3:1-- 57.2 1.0 76.2 .0 762 7.4 3.0 w 63.5 1.6 65.9 1.3 85.9 5.9 -- 3.00 SS 4. T 76.2 2.4 151.6 2.6 101.6 3.5 8.6 2.555 13.-1 82,6 3.5 124.0 3.9 124.0 5.4 325 8.5 4.58 8.8 428 12.0 82.6 3.9 524.0 3.9 124.0 5.4 165.1 250 12.0 5.54 11.00 5.50 155 88.9 5.4 539.7 5.8 139.7 0.8 3.50 12.0 5.55 112 5.55 152 88.9 5.4 139.7 5.1 139.7 6.9 4.25 23.0 0.58 23.4 6.88 312 709.0 10.4 174.8 70.6 7748 14.2 55231w 555555 2/5 558110 5555523 25558 58512310 oIIowprn.n,sc,.,e,..I00,wgoc,,.,Øwg.awuc., Th.,.00flOn00008lo0Io 01re0n.,.,100 Cnn Fib n1lO10110000. C,tnd line fl,o PrS,0i., 0000,. L 12 2-2 3.0 5.8 8.5 11.8 81 13 - 17.0 -793 26.0 13-4 b Flgum50l FiguroSlO Fig.. 519 Figme5l00E 45° Elbow 90 Elbow Tee 90° Drain Elbow Nonsno dm1. mlO 10851. C85E A 5- l. Inches Lbs. 1feb05 s. Inches Lbs. Inches Inches Inches Lbs. SIZe mm Ks mm K, mm Kg. mm mm mm 5823 Th 445 0.4 09.9 0.5 69.9 0.6 - -:-:- is 5851 58510 44.5 0.5 69.9 0.5 69.9 0.8 - - 255_ -i:s- i - - - 2 50.8 0.8 82.6 0.9 82.6 1.2 - - • - 5800 123 3.75 3-75 _235_ 171 2/n 57.2 1.8 95.3 1.4 95.3 2.6 85.3 50.8 69.9 1.2 - IlO 5.00 551 3555 058 S 63.5 7.6 708.0 2.0 708.0 3.2 188.0 59.4 69.9 1.7 1051 ® 23 585155 225 S - 762 2.4 127.0 3.9 727.0 5.4 727.0 72,4 69,9 3.2 0510 0580 585855 585855 100 82.6 3.9 139.7 6.7 139.7 7.7 139.7 85.9 69.9 5.9 - 5051 000 58580 585855 585855 5Y0 6 88,9 5,4 165,1 0,4 165,1 11.8 165,1 99.6 69.9 6.1 7.75 soo 00 808.0 /0,4 195.9 76.6 796.9 20.4 196.9 125.? 69.9 11.9 Fscson Reswmnce lOIS, 0150155160 (Expressed as, Equivalent SIlo/ct Pipe) Sloe 957 357 810n05 Run Feet Feel Feel Feel Inches mm -5- Meters Meters - Motels Motels 10 T6 65.3 1.0 0.5 2.5 1.0 0W 555 555 9.8 73.0 7.2 0.6 3.0 7.2 7 1 4.1 2.1 10.3 4.1 7.2 0.6 3.1 1.2 & 88.9 1.5 0.7 3.7 7.5 4 5.5 3.3 16.3 6.5 174.3 2.0 7.0 5.0 2.0 0.0 4.1 25.0 8.0 2.4 1.3 6.7 2.4 5 8.2 4.1 20.5 02 141.3 2.5 1.3 6.3 2.5 651 9.5 3.8 23.8 9.5 2.9 7.4 7.2 2.9 6 9.9 5.0 24.6 9.9 768.3 3.0 1.5 7.6 3.0 219.7 40 2.8 10.0 4.0 P4gO4016 TFP1810 Figures 250 and 350 Figure 250 Cost t.-El0E- Fabricated. 57106° Figure 350 Fabricated 5510081157 woo: So., rrsttc,00 no ne.ucsfl 000*,cdnot. hr Fige 250 COO, -- new0,nncrnommcnuren,rlyomwoln Omens 0001,50050. ADA CAP® Patented Figums 250 and 350 Concentric R04000l-l3ro000 010,0000 New/nM 010 E Appe. WI Nominal E 10 E 99pn. WI. Now/bob E tOE 8,900. WI. Sloe IncItes Lbs. Sloe los/ins Lbs. Si,.,, Inches Lbs. mm Inch., mm _ç Inches mm KS 2.50 1.0 35.0 42 4.00 5.8 251/, 63,5 0.5 '139.7- 139.7.., 03 959 1.9 605 101.6 2.6 2.50 1.3 • 3.50 4.4 5.00 12.2 2014 63.5 0.6 139.7,o04 88.0 2.0 8112 827.0 5.5 2402 2.50 12 5014 3.50 4.6 , 5.00 12.1 5.35 05 08.9 2.1 852/, 127.0 5.5 76.1,., 14 c 2.50 1.5 SoS 3.50 4.6 803 5.00 12.0 63.5 0.7 08.9 2.1 127.0 5,5 2.50 1.6 3.59 4.5 5.00 11.9 76.1..,n2 63.6 0.8 5c2/n 88.9 2,0 854 727.9 5.4 3c1/. 2.50 1.3 503 3.50 4.4 5.00 11.3 635 86 88.9 2.0 6.5 127.8 5.1 2.50 1.3 3.50 4.5 5.00 10.8 38l4 633 0.6 5e4 88.9 2.0 8e6 1O 49 302 2.50 1.3 • 4.00 S. 6.00 21.9 Flgute 350 635 0.6 165.1..,53 107.6 25 1004 1824 10.0 3.00 1.5 4.00 6.0 6.00 21.6 3024 76.2 07 '165.1-165.l.,04 101.6 27 152.4 9.8 350 2.0 4.00 5.6 6.00 21.1 3076.1.., 762 0.9 165t..,,I295. 101.6 2.5 10c6 152.4 9.6 3.00 -Etc F__i 2.2 4.00 0.0 6.00 19.5 45 1/. 762 IS 602 701.6 2.7 152.4 89 3.00 2.3 4.00 6.0 7.80 295 4014 76.2 1.0 0024 101.6 2.7 loxe 177.8 13.6 1204 i,s 12., - 402 3.00 2.3 _ 6o76.I.., 4.00 6.0 7.00 30.0 762 1.0 101.6 Z7 1226 '4 , 02/, 3.00 2.3 603 4.00 6.0 1208 7.00 28.0 762 1.0 101.6 2.7 1778 127 3.00 32 • 4.00 5.9 7.00 33.0 4176.7., 76.2 1.5 614 101.6 2.7 12010 177.8 75.0 i5151 2.6 4.00 6.3 76.2 1.2 60 139.7,c 101.6 5.9 Fe Nominal Dimensions T.k~ Gunter to End Wt Not lbchos Inches Inches Inches Inches Inc 11, hes 1.25 1.75 1.89 0.77 31.8 44.5 48.0 0.3 o 1.25 1.75 1.89 0.77 1.900 49.3 31.8 44.5 48.0 0.3 1.37 34.8 2.00 50.8 2.02 51.3 0.88 0.4 125 1.75 1.89 0.92 37.8 44.5 48.0 8.4 o 1.25 1.75 1.89 0.92 2.375 60.3 31.8 43.5 48.0 0.4 1.37 2.00 2.02 1.06 34.8 58.8 51.3 . 0.5 1.47 1.97 1.89 128 37.3 500 48.8 0.6 o 2.875 1.47 1.07 129 128 73.0 37.3 50.8 40.0 0.6 1.37 2.00 2.02 1.50 34.8 50.8 51.3 5,7 Page 5016 57P1810 Figures 391, 392, 393, 312 and 313 111 llO 391 U D' Figure 392 393 Figure 312 c6i Fg- 313 Fsgures 391. Figure 312 Figure 313 - 392 and 393 22'h*Etb. F to F Apps. WL Clo F Appo. WI. C to 6 8pp0. WI Nominal size 061015 - Lbs. Inches Lbs. Inches Lbs. • 1 4.50 -- 0.8 -- 1.75 -- 0.4 - 1.38 - 0.4 101.6 0.4 44.5 0.2 35.1 02 • 4.00 0.9 175 0.5 1.30 0.5 101.6 0.4 44.5 112 35.1 0.2 2• 4.00 12 1.00 0.6 1.38 0.6 101.6 0.5 47.0 0.3 35.1 0.3 • 4.00 1.9 2.00 0.7 1.50 1.1 107.6 0.9 508 03 30.1 0.0 • 4.00 2.5 225 1.4 1.50 12 101.6 1.1 572 0.6 38.1 0.5 6.00 5.5 2.63 2.4 1.75 2.2 152.4 2.5 66.0 7.1 44.5 7.0 - 6.00 7.0 2.66 4.1 2.00 3.3 152.4 3.4 732 7.9 50.8 7.5 6.00 9.5 3.13 5.8 2.00 4 .6 152.4 4.3 79.5 2.5 50.8 2.1 0 6.00 14.2 3.68 11.1 2.00 8.7 152,4 6,4 98.6 5.0 50.8 3.9 10 • 8.00 27.0 4.38 14.0 2.13 9.1 2032 122 11,3 6.4 54.1 4. 1 12 0.00 33.0 4.08 22.0 2.25 16.7 203.2 15.0 124.0 10.0 572 7.6 Figures 327 and 341 o11 Fig,, e327 Figu. 381 Figure 321 21 educing Tee Noel/nA C to F Apps. WI N000sel C to F App, WL 508 echos Lbs. 2.00 Inch.Lb, MO.met _j noSes lOOt Kg t'A . VA . 1 3.25 20 6.6.4 6-10 26.6 165.1 12.1 11 325 2.7 6.50 272 . 82.6 1.2 165.1 122 2½e2½017 375 4.2 1 .9 80802 5952 16.2 , 6.4 2½021501½ 75 8.803 7.75 36.S 95.3 iM9 196.9 16.6 .5 o 21h o 2 ° 7.75 36.8 85.3 2.0 196.9 16.6 030 425 52 8 ° ° 8 7.75 36.8 108.0 2.4 156.9 16.7 3e302 425 5.5 80806 7.75 37.0 108.0 796.9 76.8 214 425 5.8 10 0 10 2 9.00 57.1 158.0 2.6 228.6 25.9 040 17 552 9 .8 10 0 100 9.00 57.4 127.0 4.4 278.6 260 5.00 9.9 IOX 1OX4 9.00 57.8 127.0 4.5 228.6 26.1 4.4x2 5.108 10.1 10 0° 9.00 57.8 127.0 46 228.6 26.2 040 5.00 10.3 10 1 0 0 9.00 52.0 127.0 4.7 228.6 26.3 5.00 10.5 ° 10° 1 8 9.00 58.4 127.0 4.8 226.6 26.5 5 502 5.50 14.5 1201203 ' 1 0.00 00 2 139.7 6.6 254.0 36.4 S 5o2½ 5.50 14.8 1201204 10.00 80.5 139.7 6.7 254.0 36.5 50503 5.50 152 1201205 16.00 80.7 039.7 6.9 254.0 36.6 50584 5.50 15.8 '1201206 10.00 00.9 139.7 7.2 254.0 36.7 6 602 8.50 26.5 1201208 10.00 91.4 77.9 254.0 47.5 60602½ 2.50 26.5 12012010 10.00 91.8 _________ 165.1 12.0 254.0 41.6 6 603 6.50 26.5 165,1 12.0 General Notes. It is the Designers rospons4t'619 to setent produots suituble for the intended service 40810 ensure th8tpressurnrotergsundpertsneueoodulu errolooceedod. #loeys re.0ri 804 understand the irstelloionirrstrsot'ons (IH-1000). Never remove any piping component or Correst or meAty any piping deficiencies without lAst deprosnurieing and 4roieo10 the sysrrm. Mtorici 008 guskol snl0ctiee should be v041iO4 1050 oolnpul/bls for Itre npooil'o upptiouson. TYCO FIRE PROCUCTS, 451 14000 C.0cncs Avenue, Lunsdulo. Pennsylvania 19946 Fr/clod U.S.A. Page 6016 Figure 321 rtge 1 01 1 Fvaco® [&J Ffreriiser Grooved Butterfly Vllve UL, ULC Listed! FM Approved Specifications Working Pressure: 175 P51(12.5Bars) Max. Test Pressure: 350 P51(25.0 Bars) Max, Working Temp.: 250F (120C) Factory Installed UL Listed Double Tamper Switches Valve Approved For Indoor end Outdoor Use Grooved End to Suit ANSI/AWWA and 5$ Pipe Size Primary Materials: Body ASTM A-536 Nylon. 11 Coaled Disc ASTM B536 EPDM Encapsulated Upper&Lowr Sterns AISI 420-SS Worn Gear Shaft 814 410.SS Housing ASTM A-536 Hand Wheel ASTM A.536 FLag indicator ASTM A-536 $harPiri ASTMA-510 Segment Gear ASTM B148 Homing Gasket EPDM Grade'E" 0. Rinqs (All) EPDM GradeE - Fig to,:D0 <S> FM LISTED APPROVED Dimensions(ln/mm): 2.5165 411105 1 3.3/85 3.7/94.6 1 2.9173.0 5.31135 4.91125 -- 4 4136/92 38/l$4I 3/8 49 4 /100 5.71145 1 4.34/108 4.5/115.4 I 4.611162 5.3/135 4.9/125 1.—--- flTFiT 8/200 80/204 6.71170 6.7/170 8.6/219.1 7,6/493 8,9)225 0.9/24 r') hltoi tiou ttnh (iv.qt1 :.VJt(. (\C) r/'cii,-r,10-,Lrv-7J 1lI'l.'1 Fig. 200 - "Trimline" Adjustable Band Hanger Size Range - 1/2' thru 8' pipe Material - Carbon Steel, Mu. Galvanized to G90 specifications Function - For fire sprinkler and other general piping i:. .. purposes. Knurled swivel nut design permits hanger adjustment after installation. Features - (1/2' thrLi 2') Flared edges ease installation for all pipe types and protect CP\/C plastic pipe from abrasion. Captured design keeps adjusting nut from separating with hanger. Hanger is easily installed around pipe. (21/' thru 8" Spring tension on nut holds it securely in hanger before installation, Adjusting nut is easily removed. Approvals - Underwriters Laboratories listed (1/2" thru 8') in the USA (UL) and Canada (cUL) for steel •. .,7N(i 111.2 1 Hi..) '. I2H and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SF-69, Type 10. Maximum Temperature - 650 2F Finish - Mil. Galvanized. For Stainless Steel materi- als, order TOLCOT1 Fig, 200WON. Order By - Figure number and pipe size Dimensions Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Length 1/2 3/8 8mm or 10mm T/B 25/a 400 ii 3/4 3/8 8mm or 10mm 31/8 21/8 400 11 1 3/8 8mm or 10mm 33/4 21/a 400 12 1/4 3/3 8mm or 10mm 33/4 2/ 400 13 1/2 3/8 8mm or 10mm 31/6 2/ 400 14 2 3/8 8mm or 10mm 4/2 3 400 15 2/2 - 3/8 -- 10mrn5/8 41/8 600 27 3 3/8 10mm 57/ 4 600 29 31/ 3/8 10mm 71/s 51/ 600 34 4 3/8 10mm 7-1/s 5 1000 35 5 1/2 12mm 9/8 61/ 1250 66 6 1/2 12mm 101/0 0 1250 73 8 1/2 12mm 131/, 8/4 1250 136 Main 0IFice/fViar1u1aclurir3q Facility )/i 1:1i1It.'n C:nim. • ti • r.'.. ro Ii 0:130 Customer Service 131, www to/co. corn res 3/8' thru 7/8" rod in 1" incfnts Material -- Carbon Steel Maximum Temperature 750F Finish - Plain Note - Available in ElectroGalvanized and HOG finish or Stainless Steel materials, Order By - Figure number, rod diameter, rod length and finish Dimensions Weights Rod Max. Rec. Load Lbs. Size For Service Temps 650°F 750°F 3/8 610 540 1/2 1130 1010 5/8 1810 1610 3/4 2710 2420 7/8 3770 3360 Fig. 98 Rod Stiffener Size Range Secures 3/8 thru 7/8 hanger rod Material -- Carbon Steel Function - Secures channel to hanger rod for vertical seismic bracing. Finish - Electro Galvanized Note -- Available in HDG finish or Stainless Steel materials. Order By - Figure number Fig. 99 All Thread Rod Cut to Length Fig. 100 - All Thread Rod Full Lengths Size Range - Secures 3/8" thru 7/8' rod in 10' lengths Material - Carbon Steel Maximum Temperature - 750°F Finish - Plain Note Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By - Figure number, rod diameter and finish Dimensions Weights Max Rec, Load Lbs. Rod For Service Temps Approx. Size 650°F 750°F Wt./100 - 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 - 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 1 /4 8000 7140 360 VI? 11630 10370 510 Main ofriceiManu!aciurinq Facuity • 11/h './p Av' ):ii. (:A 929 19'Ph 909 /3/ ,,92; 9 11/ 0.130 I Customer Service • www.tolco.com ® T':fL,)L;o I@" LISTED 21/2" (65)1O0i-21/zXi1 I4 "-3~-"147.2(66.7) 1604 (727) (80)1001-3.Xi'1•/4 UL 3" 168.7 (76,5) UL 4" (100) 1001-4X1 160.9 (73.0) 1001-4X1114 182.4 (82,7) UL 6" 8L (150) 1001-6X 1 190.0 (86.2) 100i-6X 11/4 211.4 )95) UL 8" (200) 1001-8 Xi 217,4 1 (98.6) 1001-8X 1114 238 (108.3) UL See load ratings in UL Listed Design Load chart. * The loads listed are axial loads on the brace, The horizontal load capacity, H, of the brace is: H = F x sin ?, where ? is the installation angle measured from the vertical. Fig. 1001 - Sway Brace Attachment Size Range: Pipe size to be braced: 21/2 (65mm) thru 8" (200mm) IPS. * Pipe size used for bracing: 1" (25mm) and 11/4" (32mm) Schedule 40 IPS. Material: Steel Function: For bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system: Fig. 1001 is used in conjunction with a Fig. 900 Series fitting and joined together with bracing pipe per NFPA 13, forming a complete sway brace assembly. Features: Can be used to brace schedules 7 through 40 IPS, Field adjustable, making critical pre-engineering of bracing pipe length unnecessary. Unique design requires no threading of bracing pipe. Comes assembled and ready for installation. Fig. 1001 has built-in visual verification of correct installation. See installation note below. Installation Note: Position Fig. 1001 over the pipe to be braced and tighten two hex head cone point set bolts until heads bottom out. A minimum of 1(25mm) pipe extension is recommended. Brace pipe can be installed on top or bottom of pipe to be braced. Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 65. Finish: Plain, Contact Cooper B-Line for alternative finishes and materials. Order By: Order by figure number, pipe size to be braced, followed by pipe size used for bracing (I" (25mm) or 11/4" (32mm)) , and finish. Important Note: Fig. 1001 is precision manufactured to perform its function as a critical component of a complete bracing assembly. To ensure performance, the UL Listing requires that Fig. 1001 must be used only with other Cooper B-Line/TOLCO bracing products. UL Listed Design Load Sch. 7 - 1600 lbs. (7,11hN) Sch. 10 & 40 w/1 11 (25mm) Brace Pipe 2015 lbs. (8.96kN) Sch. 10 & 40 W/11/4" (32mm) Brace Pipe 2765 lbs. (12.30kN) All dimensions in charts and on drawings are in inches, Dimensions shown in parentheses are in millimeters unless otherwise specified, COOPER B-Line c®Us LISTED 9 Set Bolt Included Mounting Hardware Is Not Included Fig. 980 - Universal Swivel Sway Brace Attachment - /8" to 3/4" Size Range: One size fits bracing pipe 1 "(25mm) thru 2" (50mm), Cooper B-Line 12 gauge (2.6mm) channel, and all structural steel up to 1/4" (31 .7mm) thick. Material: Steel Function: Multi-functional attachment to structure or braced pipe fitting. Features: This product's design incorporates a concentric attachment opening which is critical to the performance of structural seismic connections. NFPA 13 indicates clearly that fastener table load values are based only on concentric loading. Mounts to any surface angle. Break off bolt head assures verification of proper installation. Installation: Fig.980 is the structural or transitional attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with the "bracing pipe' and Cooper B-Line/TOLCO "braced pipe" attachment, Fig. 1000, 1001, 2002, 4L, 4A or approved attachment to pipe to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 980 onto the "bracing pipe". Tighten the set bolt until the head breaks off. Attachment can pivot for adjustment to proper brace angle. Approvals: —Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). For FM Approval information refer to page 61, - Note: Fig. 980 Swivel Attachment and Fig. 1001, 1000, 2002, 4A or approved attachment to pipe that make up a sway brace system of UL Listed attachments and bracing materials which satisfies the requirements of Underwriters Laboratories and the National Fire Protection Association (NFPA) Finish: Plain. Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number and finish. Pat. #6,273,372, Pat, #6,517,030, Pat. #6,953,174, Pat. #6,708,930, Pat, #7,191,987, Pat. #7,441,730, Pat. #7,669,806 Fig. 4L Fig. 980 I '\ Longitudinal Brace Part ' Mtg.Hdw.Hole!; Max. Dpsign (nil")(mm) - Standard size. Cooper B-Line, Inc.'s ("Cooper B-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper B-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line Fig. 4A - Pipe Clamp for Sway Bracing Size Range: 4" (1 00mm) thru 8" (200mm) pipe. For sizes smaller than 4" (1 00mm) use 133140. Material: Steel Function: For bracing pipe against sway and seismic disturbance Approvals: Underwriters Laboratories Listed in the USA (UL) and Canada (cUL) 4" (100mm) thru 8" (200mm). Installation Instructions: Fig. 4A is the "braced pipe" attachment component of a longitudinal, lateral or riser brace assembly. It is intended to be combined with the "bracing pipe" and Cooper B-Line/TOLCO transitional and structural attachment component(s) to form a complete bracing assembly. NFPA 13 guidelines should be followed. To Install: Place the Fig. 4A over the pipe to be braced, Attach Cooper B-Line/TOLCO transitional fitting, either Fig. 980, 910, 909, or any other Cooper B-Line/TOLCO approved transitional fitting. Tighten bolts and nuts; torque requirement is a minimum of 50 ft/lbs. (68Nm). Transitional fitting attachment can pivot for adjustment to proper brace angle. Finish: Plain, Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, pipe size and finish Note: Please refer to Fig. 4L for longitudinal brace applications for 2" (50mm) - 8" (200mm) pipe sizes, c®US LISTED ntius ass sex nuts inciuxea Fig. 4ALongitudinal Brace ,Part No in Pipe Size'. (mm) in An (mm ..:R iii minl C in (mm ... in miii Size BoItDesignLoad Max Horizontal lbs .tJLF1OO lbs Approx (kN) (kg) Cooper B-Line, Inc.'s ("Cooper 9-Line") seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components, resulting in a listed seismic bracing assembly. Cooper-B-Line's warranty for seismic bracing components will be the warranty provided in Cooper B-Line's standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line's warranty, Cooper 8-line makes no warranty relating to Cooper B-Line's seismic bracing components that are combined with products not provided by Cooper B-Line. All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. COOPER B-Line 3/8" Maximum Design Load 2015 Lbs. Weight/100 237.5 Lbs. UL Listed as Hanger Attachment 6 Pipe Max. FM Approved Design Loads* 2900 — Across Beam 1350- Along Beam /............................. ii r V2, Bolt el NO J F,r,nisl,o,I TO P. MIld. V On, joist shr,oj,n 11001,01 -. ,--'\ to 00,10,,, root ,,,aler,oIs -- ii I - 1/TI S,nnv,th Pro 910 l.laypool I, - -------------- N:-........---2' ------'._..t/.. O fly dirorlico VIEW Oplionol Wood Idailor Ohov.',, Fig. 8 -- ;lLtd ... Sho,,'nwilh r ...Lj',...5g. 1(00 ci: cy Fig. 825 - Bar Joist Sway Brace Attachment Size Range - One size accommodates all TOLCO Fig. 900 Series sway brace attachments, Maximum Horizontal Design Load 2015 lbs. Material Carbon Steel Function - To attach sway bracing and hanger assemblies to steel open web structural members. Features - This products design incorporates a concentric attachment point which is critical to the performance of structural seismic connections. NFPA 13 indicates the importance of concentric loading of connections and fasteners. Permits secure non-friction connection without drilling or welding. Unique design reinforces point of connection to joist. Break off head bolt design assures verification of proper instal- lation torque (mm. 31 ft-lbs.). Approvals - Underwriters Laboratories Listed in the USA (UL) and Canada (cUL). Approved by Factory Mutual Engineering (FM). Included in our Seismic Restraints Catalog approved by the State of California Office of Statewide Health Planning and Development (OSHPD). For additional load, spacing and placement information relating to OSHPD projects, please refer to the TOLCO Seismic Restraint Systems Guidelines. Installation Instructions - The Fig. 825 is the structural attachment component of a longitudinal or lateral sway brace assembly. It is intended to be combined with a TOLCO transitional attachment, bracing pipe and a TOLCO braced pipe attachment, to form a complete bracing assembly. NFPA 13 and/or OSHPD guide- lines should be followed. To Install — Place the Fig, 825 on the steel beam, tighten the cone point set bolts until bolt heads break off. Attach other TOLCO transitional attachment fitting, Fig. 909, 910, 980 or 986. Transitional fitting attachment can pivot for adjustment to proper brace angle. Important Structural Note: , The TOLCO Fig. 825 has significant UL established design loads, however, struc- tural issues related to the steel joist member require restricted location installation for all bracing. Steel Joist Manufacturers require that all earthquake bracing connections be within 6' of the cord panel point. Installation of the Fig. 825 must be limited to the outer third sections of the joist span. For instal- lations within the center third section of the joist span, use UL Listed TOLCO Fig, 825A. Finish -. Plain, Electro-Galvanized and HDG Order By - Figure number and finish US Patent #6,098,942, Canada Patent #2,286,659 * The loads listed are axial loads on the brace. The horizontal load capacity, H, of the brace is: H = F x sin 0, where 0 is the installation angle measured from the vertical. TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed seismic bracing assembly. DISCLAIMER - NISCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used. OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. CORONA, CA 52879 PH: 951.737.5599 FAX: 951.737.0330 I CUSTOMER SERVICE. 800.786.5266 www.tolco.com Component of State of California OSHPD Approved Seismic Restraints System c@ US LISTED Fig 825.-.. itlkl - May psol n aoydllocPon Fig. IWO SIDE VIEW I/OS 1/08 P.O. Box 3365 South El Monte, CA 91733 626444.0541 Fax 626.444.3887 www. Afcon.org P.O. Box Box 3365 South El Monte, CA 91733 626.444.0541 Fax 626.444.3887 www. Afcon.org 100 162 REVERSIBLE UNIVERSAL BEAM CLAMP 3/4" MOUTH RESTRAThIING STRAP SIZE - 3/8' and 1/2" rod. MATERIAL- Ductile iron, FINISH - Plain, E.G. and HOG. LISTINGS - e!9ar 203-EX 2551 <€i> Approval guide - Pipe tinogern FUNCTION - Hanger assembly attachment to steel flange with thitkness of less than 3/4'. INSTALLATION - Per NFPA 13 with set screw up or down. Torque - 3/8"= 60 inch lbs. or 1/2= 125 inch lbs. In the absence of a torque wrench, engage set bolt finger tight then additionally tighten 113 turn. FEATURES ° Listings allow installation with set screw up or down - see drawings. Maintains CONSTANT HANGER CENTER-LINE, with set screw up or down. * Flat throat back to prevent twisting on flange during installation. ORDERING - Part #, rod size and finish. SIZE- One size fits both 3/8' and 1/2 rod or set screw. Available lengths 4' and longer. MATERIAL - Carbon Steel. FINISH - Mu. Galvanized. LISTINGS - nlr, 203-EX 2551 PATENT - No, 5,897,088 FUNCTION - To enhance banger attachment in areas subject to Earthquakes. INSTALLATION - Install right to structure and component pacts Minimum return on strap: I" L-dimension is measured from hanger rod center to the strap end. FEATURES Fast installation for new construction or retrofit. ° Requires no banger disassembly to install. IMPORTANT NOTE: 'No Nut Is Required" When installed right to structure and component parts. (See drawings provided) ORDERING - Parr 8 and L-dinsension. 1 APPROVED 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1,5 8008957 GST 20 X 2-1/2 850 1,5 8068925 GST 20 SS X 2-1/2 850 1.5 8010957 GST 30 X 4 1500 1.5 8009925 GST 25-380 X 4 1500 1,5 8022925 SWG 25-380 X 3-1/2 - 4 1500 1,5 8021957 SWG 20 X 2-1/2 3** 1250 1,5 8073925 SWG 20 SS X 2-1/2 1250 1,5 8139957 SH GST 2O X 3 1050 1.5 8141957 SH GST 3O X 4 1500 1.5 8140957 SH GST 20 SS X 3 1050 1.5 8142957 SH GST 3OSS X 4 1500 1.5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1,5 X 4 1475 1.5 X 4 1475 1.5 X 4 1475 1.5 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0,1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 Rol WW" . •• ..................10 1 , 8059957 CST 20 X 4 8061957 SWC20 X 4 1475 3000 PSI 1475 3000 PSI * SWG 25-360 Maximum pipe size in composite wood joist allowed by UL is 3-1/2' SWG 25-380 Maximum pipe size in wood timber or joist allowed by UL is 4" cP af I ** SWG 20 Maximum pipe size in composite wood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipe size in wood timber or joist allowed by UL is 3" 1 11,1,17 UL and FM tests were performed in compliance with NFPA-13 Standards. www.itwbuildex.com Fastening requirement: 5 times weight of water filled schedule 40 pipe plus 250 pounds. 800-284-5339 SSS26 MAT4? ST PAST: MATESIAL: HANDLE STEEl. STEM ROD BRASS BALL C.P.BRONZE BODY BRONZE SIGHT GLASS VALVE SEAT BEFAl/" IMPREGNATED TEFLON INDICATOR PLATE STEEL HANDLE LOCK SPRING STEEL MODEL 1000 MODEL 1000 300 PSI r M'11;iw "Am RPM I *G"" 3/4!' it, 11/4" 11/2 2" 3/4" 1" 11U' 1112" 2" Pi.AN ViEW FONTViEWf/ERTiO/si INSTAllATiON O The AGF Manufacturing Inc. Model 1000 TESTANDRAIN Provides Both The Test Function And The Express Drain Function For A Wet Fire Sprinkler System. 0 The Model 1000 Complies With All Requirements Of NFPA-13, NFPA-1 3R, And NFPA-13D. U The Model 1000 TESTANDRAIN Is A Single Handle Ball Valve That Is Light Weight And Compact. Includes A Tamper Resistant Test Orifice, Integral Tamper Resistant Sight Glasses, And Is 300 PSI Rated. O Available In A Full Range Of Sizes From 3/4" To 2" NPT & BSPT. With All Specifiable Orifice Sizes /81, 711eJ, 1/1, 17/33", J8" (ELO), 3/4" (ESFR) and K.25. O The Orifice Size Is Noted On The Indicator Plate And The Valve Is Tapped For A Pressure Gauge. 0 The Standard Model 1000 TESTANDRAIN Valve Includes A Pressure Gauge Port Tapping And Can Be Ordered With A Relief Valve As A Model 1011 Or 1011 0 Locking Kit Available Which Provides Superior Vandal Resistance And Prevents Unintentional Alarm Activation. G r. Visit us •4,-,. on the Internet at ORIFICE SIZE AVAILABLE - 3/8", 17/16", 1/2', 17/33", ELo(5/8), ESEEEI/4T and 1(25 "Avolloble on 11/2, to 2 sIze units only. DIMENSIONS - INCHES SIZE A B C 0 F F C H 3/4'" s',e' 1 ½' 23/16- 3 51e'" 3 'a" 1 Iio" 4Iia" + 6 31( 61e ,. 3 C8" 2 'ie" 8 14" 10 7/x" 2 5134,0,, 45.54,0,, 51.505,4, l57,, 99,5.0,, 6&51,,55 99943.05 2.7340,9,, 2' 6 'ITA" 1 1I16" 3 TI,," 5111 3 08" 25/s' 8 "V10 Is" T63.33,,,v, 4S$Isv?v 81.50,,s,, 5/so, 95.10.0, 93.9,,,,,,, 20649,0,, 973429,,, '"3/4" Volvo UL Wed or,TIL - . AGF Manufacturing Inc. ULL090G 00dB/B l0Oks,Lte4,13,Ivwv,PAIS3SS JOB NAME: Il/' 9 l51TIi399/ElB9oTv2IL3eoL ji ARCHITECT: ENGINEER: 5.00 0 +45 CONTRACTOR FROM BRANCH GAUGE INLET / PROVIDED x STREET a TOURIsTS — OR PIPE' TO BUGS RIGi-C AiDfS7SAiGilT NSTALLATO>/ APPROVALS: UL and ULC Listed FM Approved except 3/4' U NYC-BSA NO. 720-87-SM U CA. State Fire Marshall Cocurco,. nen.-Les Inn n-nt or nnncc (!f?PO1TE VSRF VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD ® POTTER The Symbol of Protection \ISR-F VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD U.S. Pat. No. 3921989 Canadian Pat. Na. 1009680 Other Patents Pending Potter Electric, Rd., 1900 GENERAL INFORMATION The Model VSR-F is a vane type waturfiow switch for one on wet sprinkler Systems. It is UL Listed and FM Approved for use an Steel pipe: schedules 10 through 40, sizes 2' thru 8' (50mm Ibm 200mm). LPC approved Sizes are 2' thru 0 (50mm Ibm 200mm). The and may also be used as a sectional wotentlaw detector on large Systems. The and contains two single pole, doable threw. Snap action switches and an adjustable, instantly recycling pneumatic re- tard. The switches are actuated when a 00w at 10 gallons per minute (38 LPM) or more occurs downstream at the device. The flow condition mast exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general parpase, dre- cast housing. The cover is held in place with two tamper resis- tant screws which require a special key for removal.A field in- statable cover tamper switch is available as an option which may be used In indicate unauthorized removal of the caner. See bulletin no. 5400775 for installation instructions of this switch. ULULCandCSFMLioted,FMandLpCBApproned,NYMEA Accepted. CE Marked SecePreourare: Uptu450 PSI (31 BAR) Minimum FlowRateforAlarm:IOGPM (38LPM) Maoirtrram Surge: 18 FPS (5,5 m/s) ContoctRaeingu: Two sets 01 SPOT (Form C) 15.0 Amps at 125i250VAC 3.0 Amps at 30VOC Resistive Condoit Entrances: Two knockouts provided Strict' conduit Environmental Specifications: - Suitable for indoor uroutdoor use with factory instated gasket and die-cost housing. - NEMA 4/tP54 Rated Enclosure - use with appropriate conduit fitting. Temperature Range: 40F/120F, 4,5C/49C Non-corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10thru40, sizes 2' tires 0' BS 1387 pipe 50mm Ibm 200mm Note: For copper or plastic pipe use Model VSR-CF. Service list: Automatic Sprinkler NFPA-13 One erlma famdydweting NFPA-130 Residential occupancy up to foarstnnes NFPA-13R National Fee Alarm Cede NFPA-72 Optional: CoverTumper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted an horizontal or vertical pipe. On horizontal pipe they should be installed on the lop side of the pipe where they will be accessible. The units should not be in- stalled within 6' (15cm) of fitting which changes the directional the matertlom or within 24 (60 cm) of a valve or drain. Drain the system and drill a hole in the pipe using a circular Sam inn slow spend drill- The 2(00mm) and 2 1/2 (65mm) devices require a hole with a diameter of l/d' * 1/0' - 1/18' (33mm *2mm). All other sizes require a hate with a diameter ofT *1/8' (50mm *2mm). Clean the inside pipe of all growth or other material for a dis- tance equal to the pipe diameter on either side of the hole. Roy the vane so that it maybe inserted into the hole; do not bend or crease II. Insert the vane so that the arrow on the saddle points in the direction of the matertlom. Install the saddle strap and tighten nuts alternately to an eventual 50 ft-lbs. (60 n-rn) of torque (see Fig. 2). The vane mast not rub the inside of the pipe or bind in any way- Specifications subject to change without notice. FIG. I SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL CAUTION: An uninsulated section of a single conductor should not be looped around the tereri- nat and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG, S to MDT ~vt Oeroac ecurm savor -. err cur00 °' ran on, 6vtuon uxusrutac rn cruSoe TIME rara runt tcnsm n:occvvW _e"111 ma ncsleco I- E-usc rev aeaaua nurocor or 'V_strcns.zn m pnvscw ro,sr ufiuoo, a *' Scnvsc 0 usuran Paw sac 00cr sac Caner Tampnr (with cover in planet rn em ma, len Potter ElecfricSigsal Company 2001 Craia Road, St Louis. MO, 63145-4161'Phone: 000-325-3936/Conadu uOO-002-1033 v5sn.ponmsignnt.com pvin'rcn louse Inc. wormer . REV w puec r OF 2 MFG. nsaau,ur .7102 I wjmsao4acwa-m FIG.3 TYPICAL ELECTRICAL CONNECTIONS NOTES: FIG4 1. The Model VSR-F has two To remove larodroots: Place se.itehns, ann can he used to screwdriver at edge of knock- operate a covtwl stabco, pro- : ants, not in the center. 3. For supervised ci,..iu Li prietary .1 nunct. signaling 'Switch Terminal Connec- tions' drawing and caution no, ten vaIn IRa, 1). - APPUCATION WARNINGI Due to the possibility of unintended discharges caused by pressure surges, trapped air, or Short retard hrneS. watettlom switches that are monitoring wet pipe sprinkler Systems Should not be used as the Sole initialing device In discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). If provided, the inspector's lest valve, that is usually located at the end of the most remote branch line, should always be used for rest purposes. If there arena provisions for testing the operation of the 110w detection device on the system, application of the VSR-F is not recommended or advisable. A minimum 90w of 10 gpm (38 Lpw) is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system mast be tested in accordance with the testing instructions. pv,sico muse 1.1R7. reacTor - 6VW - - Pocc 2 0F2 MFI;. 05400701.7,02 No)es: Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -300 to 150F (-34° to 66°C). Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 5 005056 57*05668 0(444647 2770CR 5(100/ 78000 P00720 7745010 .704 00 70 O (001/ 10000 0104144 7780744 .700 70 77 70 mm 18V0C P007270 7770774 .104 72 70 SIRE) oovuo 0140745 7745014 264 07 70 748001 22000 r004414771742* 260 04 50 414451 44v4C 400442 1450452 .770 04 77 240*0 P044070 7414704 IrA 44 74 gpno) 144086 120075 r0247714 1010180 4SO 44 46 6 BELL SHOWN ( POTTER The Symbol of Protection ULUsted Sizes Available: 6(150mm) 8(200mm) and 16° (250mm) Voltages Available: 24VAC 12OVAC 12VDC (10.2 to 156) Polarized 24VDC (20.4 to 312) Polarized Service Use: Fire Alarm General Signaling BurglarAlarm Environment Indoor oroutdoor use (See Note 1) -40° to 150F (40° to 66°C) (Outdooruserequiresweatherproot backbox.) Termination: 4 No, 18 AWG stranded wires Finish: Red powder coating Optional: Model 88K-1 weatherproof backbox These vibrating type bells are designed for use as lire, burglar or general signaling devices. They have low power con-sumption and high decibel ratings. The unit mounts on a standard 4 (101mm) square electrical box for indoor use or on a model 88K-1 weatherproof backbox for outdoor applications. Weatherproof backbox model 881<-1. Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: Pone( Electric sn2i Company - 2081 Cmig Road. Si. Louis. MO. 6314154161 - Phoo7:050-325.393tiC0000o 008.002.1033- v18ow.pottersignul.co,n p0(4700 IN USA .,Cr. 40850001 .6EV S PAGE 1 OF 2 MFG. 05400776.5185 P) POTTER \5om0 The Symbol of Protection DIMENSIONS INCHES (mm) FIG. I BELLS FIG. 2 WEATHERPROOFBACKBOX BOXHASONETHREAOED 1(2CONOUITENTRAGCE ftD__ 2 i - S111 loll #rru-o FiG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) A.C. BELLS (R( , 442000 42075 (R( 57446 4171 2007:01z000:00 41910 ___ ___ 01261 ____ ____ 00410* units uoltST 1. OOSCOvE 018554545 m 0105 05. 004.45. I. 407(0 OSQIC AC. 001.5. 7E4u401A1E (504 CR700 SIRE 5040001(45 2, RED 01065 P69756 14) IntO LISP 385. 3. 5(201 42565 uECAR6E (-I a. oio-OF-uwo wslsom s ijor nc000wu aloE. 64545. Oiwc. ff77e-3 INSTALLATION The belt shall be installed in accordance with NFPA 72 or local Ahj. The top of the device shalt be no less than 90 Aft and not less than & below the ceiling. Removethegong. Connect wiring (see Fig. 3)- Mount belt mechanism to backbox (belt mechanism must be mounted with the striker pointing down). Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). PR/AlSO IN USA MKL48450004.4IE1J5 P5082012 l.IFG. 05440770.sius ES-A-3000SS Series 3000SS A A M E S Double Check Detector Assemblies FIRE Sizes: 21/2 - 12' (65 - 300mm) Series 3000SS Double Check Detector Assemblies are designed for use in accordance with water utility non-health hazard containment requirements. It is mandatory to prevent the reverseflow off ireprotection system substances, i.e., glycerin wetting agents, stagnant water and water of non-potable quality from being pumped or siphoned into the potable water supply. Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a drinking water supply. Degree of hazard present is determined by the local authority having jurisdiction. The main valve body shall be manufactured from 300 Series stainless steel to provide corrosion resistance, 100% lead free* through the waterway. The double check detector assembly consists of two independently operat- ing, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double check including shutoff valves and required test cocks. Each cam-check shall be internally loaded and provide a positive drip tight closure against reverse flow. Cam-check includes a stainless steel cam arm and spring, rubber faced disc and a replaceable seat. There shall be no brass or bronze parts used within the cam-check valve assembly. The check valve seats shall be of molded thermoplastic construction. The use of seat screws as a retention method is prohibited. All internal parts shall be accessible through a single cover on the valve assembly. The valve cover shall be held in place through the use of a single grooved style two-bolt coupling. The bypass line shall be hydraulically sized to accurately measure low flow. The bypass line shall con- sist of a meter, a small diameter double check assembly with test cocks and isolation valves. The bypass line double check valve shall have two independently operating modular poppet check valves, and top mounted test cocks. The assembly shall be an Ames 3000SS. Materials All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series stainless steel, Check assembly: Noryl® Flange dimension in accordance with AWWA Class D. Noryl® is a registered trademark of General Electric Company. A WARNING It is illegal to use this product in any plumbing system providing water for human consumption, such as drinking or dishwashing, in the United States. Before installing standard material product, consult your local water authority, building and plumbing codes. Contractor Approval Contractor's P.O. No. Representative.._._ Features Cam-Check Assembly valve provides low head loss Short lay length is ideally suited for ret- rofit installations Stainless Steel body is half the weight of competitive designs reducing installa- tion and shipping cost Stainless steel construction provides long term corrosion protection and maximum strength Single top access cover with two-bolt grooved style coupling for ease of main- tenance No special tools required for servicing Compact construction allows for smaller vaults and enclosures Furnished with %' x 3/4' bronze meter (gpm or cfm) Detects underground leaks and unauthorized water use Maybe installed horizontal or vertical "flow up" position Available Models Suffix: LG - less shutoff valves OSY - UL/FM outside stem and yoke resil- ient seated gate valves OSY FxG -flanged inlet gate connection and grooved outlet gate connection OSY GxF - grooved inlet gate connection and flanged outlet gate connection OSY GxG - grooved inlet gate connection and grooved outlet gate connection CFM - cubic feet per minute GPM - gallons per minute meter Post indicator plate and operating nut available - consult factory *The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Job Name - Job Location Engineer _ Approval - Ames product specifications In U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contact Ames Technical Service. Ames reserves the right to change or modify product design, construction specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames products previously or subsequently sold. amesfirewater.com I I A Pressure - Temperature Temperature Range: 33°F - 110°F (0.5°C - 43°C) Maximum Working Pressure: 175p5i (12 bar) Capacity Flow curvesastested byUnderwriters LaboratoryperUL 1469,1996. * Rated flow **UL Tested 4J MMMMMONMEIMMMM --= R• .7. ______. I__p !• kPa PSI 3 15 4" (100mm) ** 83 12 41 6 LWHThH 21 3 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 gpm 171 380 570 760 950 1140 1330 1520 1170 1900 2090 2280 2470 26602850 1pm 5 10 15 fps 1.5 3 4.6 mps Standards ASSE 1048, AWWA C510-92, CSA B64.5, UL 1469 Approvals UL Classified (OSY only), FM (sizes 21/2 —10, OSY only) SUP RSB < C) > Approved (!J) kPa psi 6" (150mm) * ** WOMMMMMMMMMOMOM WWWOMOMMOMENNOW OMMMOMMMMMEMMMM Ll flmmmmmmlmm • ii — u•ui. ______I U ___I , u•u l •••u _IIJ 'I.... u.IU ._. p . I of oil u fit II 11 111 SIZE (ON) DIMENSIONS NET WEIGHT NET WEIGHT In. mm in. A mm in. C (OSY) mm D in. mm 8 in. mm L in. mm P in. mm w/Gates lb. kg. w/o Gates lb. kg. 21/2 65 37 965 16I8 416 31/2 89 10 250 22 559 121/2 318 155 70 68 31 3 80 38 965 18Ie 479 33/4 95 10 250 22 559 13 330 230 104 70 32 4 100 40 1016 22/4 578 41/2 114 10 250 22 559 141/2 368 240 109 73 33 6 150 481/2 1232 301/a 765 51/2 140 15 381 27V2 699 1 151/2 394 390 177 120 54 8 200 521/2 1334 373/4 959 6/4 171 15 381 291/2 749 181/2 464 572 259 180 82 10 250 1 551/2 1410 453/4 1162 8 200 15 381 291/0 749 1 191/2 495 1 774 351 1 190 86 12 300 1 57'/2 1461 531/8 1349 91/2 241 1 15 381 291/2 749 1 21 533 1 1044 474 1 220 100 A __ 08 A M E S I19OO1 -20 FIRE&WATERWORKS amesfirewater.com I CERTIFIED A Watts Water Technologies Company USA: Backflow- Tel: (916) 928-0123 If Fax: (916) 928-9333 Control Valves- Tel: (713) 943-0688 • Fax: (713) 944-9445 Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 Latin America: Tel: (52) 81-1001-8600 ES-A-3000SS 1410 0 2014 Ames Fire & Waterworks