HomeMy WebLinkAbout5150 HEMINGWAY DR; ; AS060030; Permit9/27/22,11:18 AM AS060030 Permit Data City of Carlsbad Sprinkler Permit 5150 HEMINGWAY Job Address: DR Permit Type: SPRINK Parcel No: 2081840600 Lot #: 0 Permit No: AS060030 Status: ISSUED Applied 2/22/2006 Approved: 2/22/2006 Reference No.: Issued: 2/22/2006 PC #: Inspector: Project Title: KELLY RANCH PRESCHOOL FIRE SPRINKLER SYSTEM INSPECTIONS ONLY Applicant: WEST COAST FIRE PROTECTION 271 ROYMAR RD SUITE F OCEANSIDE, CA (760)754-8472 Owner: KELLY RANCH HOLDINGS L L C 9811 W CHARLESTON BLVD #2-372 LAS VEGAS NV LFees ($) Add'I Fees ($) Total ($) Balance ($) 360 0 360 0 about:blank 1/1 Kelly Ranch Preschool Review Comments. Page 2 Review Comments Kelly Ranch Preschool, 5150 Hemingway Drive, Carlsbad, CA 1. Field verify that there is a head within 3'-O' vertically of the peak on all pitched roofs. P Kelly Ranch Preschool Review Comments. Page 2 Review Comments Kelly Ranch Preschool, 5150 Hemingway Drive, Carlsbad, CA Test hydrant location is not verified on sheet 1, however it is most likely the hydrant adjacent to reference point U3, south of the building. No revision or resubmittal required. General note 43 should be revised on future submittals to reflect that only lateral sway bracing may be eliminated if hanger rods are not in excess of 6" long. No revision or resubmittal required. General note #11 should be revised on future submittals as NFPA-13, Section A-5-13.6.2 suggests that it is acceptable for a flow switch to accomplish the required shut activation. No revision or resubmittal required. It appears there is a door breaking the laundry room into two segments. If so an additional head should be added. This can be field verified. No revision or resubmittal required. West Coast Fire Protection 271 Roymar Rd. Ste. F, Oceanside, CA 92054 Tel. (760) 754-8472 - Fax. (760) 754-8492 C-16 #763542 February 1, 2006 City of Carlsbad Fire Department ATTN: Brenda Project: Kelly Ranch Pre-School Re: Flow Test Results Address: 5150 Hemmingway Location: Gauge Hydrant - new hydrant behind building Flow Hydrant - Existing hydrant on Hemmingway Date taken: 8/16/05 @ 1:00 PM Weather Conditions: Clear/warm Static Pressure: 145 psi Residual Pressure: 130 psi Pitot Pressure: 95 psi Total GPM: 1481 GPM Sincerely, West Coast Fire Protection Dan J. Amato WEST COAST FIRE PROTECTIO1 271 ROYMAR ROAD SUITE F OCEANSIDE,CA 92054 HYDRAULIC CALCULATIONS FOR KELLY RANCH SECOND FLOOR HIGH ROOF FILE NUMBER: KELLYRANCH DATE: JUN 26, 2006 -DESIGN DATA- O APPROVED g) (z/O APPROVED AS NOTED E NOT APPROVED, RESUBMIT CHECONG IS ONLY FOR COFORMAN IHE DSGN CCCEPT uF THE F3EC'T AND CGPUANCE WITH THE ORPJN G;VEN IN THE CONTRACT OG[:"TS. CONTRACTON IS RESPONSIBLE :OS TO BE CONFIRMED 'rD CURRLLAftD AT iKE JOB SITE AND FOR COORDINATION OF THE WORK OF ALL TRADE. OCCUPANCY CLASSIFICATION: DENSITY: AREA OF APPLICATION: COVERAGE PER SPRINKLER: NUMBER OF SPRINKLERS CALCULATED: TOTAL SPRINKLER WATER FLOW REQUIRED: ORDINARY HAZARD .20 gpm/sq. ft. 919 sq. ft. 40% RED. FOR QR 120 sq. ft. = 24 GPM 8 sprinklers 201.5 gpm TOTAL WATER REQUIRED (including hose): 451.5 gpm FLOW AND PRESSURE (@ BOR) : 201.5 gpm 0 78.9 psi SPRINKLER ORIFICE SIZE: 1/2 inch NAME OF CONTRACTOR: WEST COAST FIRE PROTECTION DESIGN/LAYOUT BY: DAN ANATO AUTHORITY HAVING JURISDICTION: CITY OF CARLSBAD FIRE)2ARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 76354Z" SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 6/26/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: KELLY RANCH HIGH ROOF CALC AREA WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 145.0 130.0 1481.0 143.3 451.5 92.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 451.5 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 250.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 201.5 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 30.1 K= 5.60 19.8 24.9 2 30.1 - - - - 20.7 - - - 3 30..1 K= 5.60 18.9 24.4 4 30.1 K= 5.60 20.0 25.1 5 30.1 - - - - 20.9 - - - 6 30.1 K= 5.60 1911 24.5 7 30.1 K= 5.60 18.4 24.0 8 30.1 - - - - 21.3 - - - 9 30.1 K= 5.60 20.8 25.5 10 30.1 - - - - 22.6 - - - 11 30.1 K= 5.60 22.1 26.3 12 30.1 - - - - 24.0 - - - 13 30.1 K= 5.60 22.9 26.8 14 30.1 - - - - 26.5 - - - 15 30.1 - - - - 41.6 - - - 16 23.1 - - - - 49.9 - - - 17 23.1 - - - - 65.8 - - - 18 11.3 - - - - 71.7 - - - TOR 11.3 - - - - 73.7 - - - BOR 1.0 - - - - 78.9 - - - Ui 0.5 - - - - 79.6 - - - U2 -3.0 - - - - 81.1 - - - BF1 -3.0 - - - - 81.3 - - - BF2 3.0 - - - - 78.7 - - - BF3 3.0 - - - - 84.7 - - - BF4 -3.0 - - - - 87.4 - - - U3 -3.0 - - - - 87.4 - - - SOURCE -15.0 SOURCE 92.9 201.5 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 6/26/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: KELLY RANCH HIGH ROOF CALC AREA PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -24.9 1.080 PL 5.00 PF 0.8 1 30.1 5.6 19.8 24.9 8.7 120 FTG ---- PE 0.0 2 30.1 0.0 20.7 0.0 0.170 TL 5.00 PV Pipe: 2 24.4 1.080 PL 5.00 PF 1.8 2 30.1 0.0 20.7 0.0 8.5 120 FTG T PR 0.0 3 30.1 5.6 18.9 24.4 0.163 TL 10.76 PV Pipe: 3 -49.3 2.203 PL 12.00 PF 0.2 2 30.1 0.0 20.7 0.0 4.2 120 FTG ---- PE 0.0 5 30.1 0.0 20.9 0.0 0.019 TL 12.00 PV Pipe: 4 -25.1 1.080 PL 5.00 PF 0.9 4 30.1 5.6 20.0 25.1 8.8 120 FTG ---- PE 0.0 5 30.1 0.0 20.9 0.0 0.172 TL 5.00 PV Pipe: 5 24.5 1.080 PL 5.00 FE 1.8 5 30.1 0.0 20.9 0.0 8.6 120 FTG T PE 0.0 6 30.1 5.6 19.1 24.5 0.164 TL 10.76 PV Pipe: 6 -98.9 2.203 PL 5.50 PF 0.4 5 30.1 0.0 20.9 0.0 8.3 120 FTG ---- PR 0.0 8 30.1 0.0 21.3 0.0 0.067 TL 5.50 PV Pipe: 7 -24.0 1.080 FL 10.33 PF 2.9 7 30.1 5.6 18.4 24.0 8.4 120 FTG ET PR 0.0 8 30.1 0.0 21.3 0.0 0.158 TL 18.40 PV Pipe: 8 -122.9 2.203 PL 6.00 PF 1.3 8 30.1 0.0 21.3 0.0 10.3 120 FTG E PR 0.0 10 30.1 0.0 22.6 0.0 0.101 TL 12.82 PV Pipe: 9 -25.5 1.080 PL 4.50 PF 1.8 9 30.1 5.6 20.8 25.5 8.9 120 FTG T PR 0.0 10 30.1 0.0 22.6 0.0 0.177 TL 10.26 PV Pipe: 10 -148.4 2.203 PL 10.00 FE 1.4 10 30.1 0.0 22.6 0.0 12.5 120 FTG ---- PR 0.0 12 30.1 0.0 24.0 0.0 0.143 TL 10.00 PV Pipe: 11 -26.3 1.080 PL 4.50 PF 1.9 11 30.1 5.6 22.1 26.3 9.2 120 FTG T PR 0.0 12 30.1 0.0 24.0 0.0 0.188 TL 10.26 PV Pipe: 12 -174.7 2.203 PL 6.00 PF 2.5 12 30.1 0.0 24.0 0.0 14.7 120 FTG E PR 0.0 14 30.1 0.0 26.5 0.0 0.193 TL 12.82 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 6/26/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: KELLY RANCH HIGH ROOF CALC AREA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 12A -26.8 1.080 PL 10.33 PF 3.6 13 30.1 5.6 22.9 26.8 9.4 120 FTG ET PE 0.0 14 30.1 0.0 26.5 0.0 0.194 TL 18.40 PV Pipe: 12B -201.5 2.203 PL 46.50 PF 15.1 14 30.1 0.0 26.5 0.0 17.0 120 FTG T PE 0.0 15 30.1 0.0 41.6 0.0 0.252 TL 60.14 PV Pipe: 12C -201.5 2.203 PL 7.00 PF 5.2 15 30.1 0.0 41.6 0.0 17.0 120 FTG T PE 3.0 16 23.1 0.0 49.9 0.0 0.252 TL 20.64 PV Pipe: 12D -201.5 2.703 PL 125.00 PF 16.0 16 23.1 0.0 49.9 0.0 11.3 120 FTG 5E PE 0.0 17 23.1 0.0 65.8 0.0 0.093 TL 171.63 PV Pipe: 12E -201.5 3.314 PL 13.00 PP 0.8 17 23.1 0.0 65.8 0.0 7.5 120 FTG E PE 5.1 18 11.3 0.0 71.7 0.0 0.034 TL 23.19 PV Pipe: 12F -201.5 3.314 PL 37.83 PF 2.0 18 11.3 0.0 71.7 0.0 7.5 120 FTG 2E PE 0.0 TOR 11.3 0.0 73.7 0.0 0.034 TL 58.21 PV Pipe: 13 -201.5 3.314 PL 10.29 PF 0.7 TOR 11.3 0.0 73.7 0.0 7.5 120 FTG B PE 4.5 BOR 1.0 0.0 78.9 0.0 0.034 TL 20.48 PV Pipe: 14 -201.5 3.314 PL 3.50 PF 0.5 BOR 1.0 0.0 78.9 0.0 7.5 120 FTG B PE 0.2 Ui 0.5 0.0 79.6 0.0 0.034 TL 13.69 PV Pipe: 15 -201.5 6.090 PL 7.00 PF 0.0 Ui 0.5 0.0 79.6 0.0 2.2 150 FTG E PE 1.5 U2 -3.0 0.0 81.1 0.0 0.001 TL 28.58 PV Pipe: 16 -201.5 6.090 FL 98.00 PP 0.1 U2 -3.0 0.0 81.1 0.0 2.2 150 FTG B PE 0.0 BFi -3.0 0.0 81.3 0.0 0.001 TL 119.58 PV Pipe: 17 -201.5 6.160 FL 6.00 PF 0.0 BF1 -3.0 0.0 81.3 0.0 2.2 150 FTG B PE -2.6 SF2 3.0 0.0 78.7 0.0 0.001 TL 28.82 PV Pipe: 18 FIXED PRESSURE LOSS DEVICE BF3 3.0 0.0 84.7 0.0 6.0 psi, 201.5 gpm BF2 3.0 0.0 78.7 0.0 Pipe: 19 -201.5 6.160 PL 6.00 PP 0.1 BF3 3.0 0.0 84.7 0.0 2.2 150 FTG 2E PE 2.6 SF4 -3.0 0.0 87.4 0.0 0.001 TL 51.64 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 6/26/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: KELLY RANCH HIGH ROOF CALC AREA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 20 -201.5 11.650 PL 20.00 PF 0.0 BF4 -3.0 0.0 87.4 0.0 0.6 150 FTG ET PE 0.0 U3 -3.0 0.0 87.4 0.0 0.000 TL 137.00 PV Pipe: 21 -201.5 6.090 PL 210.00 PF 0.3 U3 -3.0 0.0 87.4 0.0 2.2 150 FTG ETG PE 5.2 SOURCE -15.0 SRCE 92.9 (N/A) 0.001 TL 282.46 PV NOTES: Calculations were performed by the HASS 7.7 computer program under license no. 27081246 granted by HRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.002 gpm and a maximum imbalance at any node of 0.051 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 17.0 ft/sec at pipe 12C. PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEii ChkVlv BfyVlv GatViv AlmChk DPViv NPTee 1.080 2.30 5.76 2.30 5.76 6.91 1.15 11.52 11.52 5.76 2.203 6.82 13.64 4.09 15.00 8.18 1.36 13.64 13.64 13.64 2.703 9.33 18.65 6.22 21.76 10.88 1.55 15.54 15.54 18.65 3.314 10.19 21.84 7.28 23.29 14.56 1.46 18.93 18.93 21.84 6.090 14.28 30.61 9.18 32.65 10.20 3.06 28.57 28.57 30.61 6.160 15.10 32.36 9.71 34.52 10.19 3.24 30.20 30.20 32.36 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 6/26/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: KELLY RANCH HIGH ROOF CALC AREA PAGE: E MATERIAL: PVC150 HWC: 150 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G N Eli Tee LngEll ChkVlv BfyViv GatViv NPTee 11.650 36.00 81.00 2400 87.00 28.00 8.00 81.00 WATER SUPPLY ANALYSIS 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) 160.0 140.0 G A U120. 0 G E P100 .0 R E S S 80.0 U R E 60.0 p S 40.0 20.0 ME -14.? WEST COAST FIRE PROTECTION 271 ROYMAR ROAD SUITE F OCEANSIDE,CA 92054 HYDRAULIC CALCULATIONS FOR KELLY RANCH PRE-SCHOOL SECOND FLOOR 20x20 CALC FILE NUMBER: KELLYRANCH DATE: FEB 1, 2006 Ej APPROVED i&) zbolft EL APPROVED AS NOTED E NOT APPROVED, RESUBMIT CHECKING IS ONLY FOR COFORMAN I TH THE OGN CONCEPT F THE PROJECT A;' COPUANCE VflTH THE I1F0C'ATON OVEN IN THE CONTRACT DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOE DO' SIONS TO BE CONFIRMED AND CORRELATED AT THE JOB SITE AND FOR CDORDFNATI0'N OF THE WORK OF ALL TRO. -DESIGN DATA- OCCUPANCY CLASSIFICATION: LIGHT HAZARD DENSITY: .10 gpm/sq. it. AREA OF APPLICATION: 1500 sq. ft. COVERAGE PER SPRINKLER: 320 sq. ft. NUMBER OF SPRINKLERS CALCULATED: 6 sprinklers TOTAL SPRINKLER WATER FLOW REQUIRED: 294.0 gpm TOTAL WATER REQUIRED (including hose) : 394.0 gpm FLOW AND PRESSURE (@ BOR) : 294 gpm @ 112.9 psi SPRINKLER ORIFICE SIZE: 5/8 inch NAME OF CONTRACTOR: WEST COAST FIRE PROTECTION DESIGN/LAYOUT BY: DAN AMATO AUTHORITY HAVING JURISDICTION: CITY OF CARLSBAD FIRE DEPARTMENT CONTRACTOR CERTIFICATION NUMBER: C-16 763542 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 2 DATE: 2/1/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: Kelly Ranch Pre-School WATER SUPPLY DATA SOURCE STATIC RESID. FLOW AVAIL. TOTAL REQ'D NODE PRESS. PRESS. @ PRESS. @ DEMAND PRESS. TAG (PSI) (PSI) (GPM) (PSI) (GPM) (PSI) SOURCE 130.5 115.5 1481.0 129.2 394.0 127.9 AGGREGATE FLOW ANALYSIS: TOTAL FLOW AT SOURCE 394.0 GPM TOTAL HOSE STREAM ALLOWANCE AT SOURCE 100.0 GPM OTHER HOSE STREAM ALLOWANCES 0.0 GPM TOTAL DISCHARGE FROM ACTIVE SPRINKLERS 294.0 GPM NODE ANALYSIS DATA NODE TAG ELEVATION NODE TYPE PRESSURE DISCHARGE (FT) (PSI) (GPM) 1 23.0 K=11.20 13.0 40.4 2 23.0 K=11.20 19.0 48.8 3 23.0 K=11.20 24.0 54.9 4 23.0 - - - - 55.7 - - - 5 23.0 - - - - 58.9 6 23.0 K=11.20 14.1 42.1 7 23.0 K=11.20 20.5 50.7 8 23.0 K=11.20 26.0 57.1 9 23.0 - - - - 60.1 - - - 10 23.0 - - - - 65.1 - - - ii 23.0 - - - - 91.5 - - - 12 11.3 - - - - 100.9 - - - TOP. 11.3 - - - - 106.6 - - - BOR 0.5 - - - - 112.9 - - - Ui 0.0 - - - - 114.0 - - - U2 0.0 - - - - 114.1 - - - BF1 0.0 - - - - 114.4 - - - BF2 0.0 - - - - 114.4 - - - BF3 0.0 - - - - 120.4 - - - BF4 0.0 - - - - 120.6 - - - U3 0.0 - - - - 120.7 - - - SOURCE -15.0 SOURCE 127.9 294.0 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 3 DATE: 2/1/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: Kelly Ranch Pre-School PIPE DATA PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 1 -40.4 1.104 FL 16.00 PF 6.0 1 23.0 11.2 13.0 40.4 13.5 120 FTG ---- PE 0.0 2 23.0 11.2 19.0 48.8 0.372 TL 16.00 PV Pipe: 2 -89.1 1.452 FL 12.00 PF 5.1 2 23.0 11.2 19.0 48.8 17.3 120 FTG ---- PE 0.0 3 23.0 11.2 24.0 54.9 0.424 TL 12.00 PV Pipe: 3 -144.1 1.452 PL 23.00 PF 31.6 3 23.0 11.2 24.0 54.9 27.9 120 FTG T FE 0.0 4 23.0 0.0 55.7 0.0 1.031 TL 30.69 PV Pipe: 4 -144.1 1.452 PL 3.17 PF 3.3 4 23.0 0.0 55.7 0.0 27.9 120 FTG ---- FE 0.0 5 23.0 0.0 58.9 0.0 1.031 TL 3.17 PV Pipe: 5 -42.1 1.104 PL 16.00 PF 6.4 6 23.0 11.2 14.1 42.1 14.1 120 FTG ---- FE 0.0 7 23.0 11.2 20.5 50.7 0.401 TL 16.00 PV Pipe: 6 -92.8 1.452 FL 12.00 PF 5.5 7 23.0 11.2 20.5 50.7 18.0 120 FTG ---- FE 0.0 8 23.0 11.2 26.0 57.1 0.457 TL 12.00 PV Pipe: 7 -149.9 1.452 PL 23.00 PF 34.1 8 23.0 11.2 26.0 57.1 29.1 120 FTG T FE 0.0 9 23.0 0.0 60.1 0.0 1.110 TL 30.69 PV Pipe: 8 -144.1 2.635 FL 20.00 PF 1.1 5 23.0 0.0 58.9 0.0 8.5 120 FTG ---- FE 0.0 9 23.0 0.0 60.1 0.0 0.057 TL 20.00 PV Pipe: 9 -294.0 2.635 FL 15.58 PF 5.0 9 23.0 0.0 60.1 0.0 17.3 120 FTG E PE 0.0 10 23.0 0.0 65.1 0.0 0.212 TL 23.58 PV Pipe: 10 -294.0 2.635 FL 93.00 PF 26.5 10 2.0 0.0 65.1 0.0 17.3 120 FTG 4E FE 0.0 11 23.0 0.0 91.5 0.0 0.212 TL 125.00 PV Pipe: 11 -294.0 2.635 FL 12.33 PF 4.3 11 23.0 0.0 91.5 0.0 17.3 120 FTG E FE 5.1 12 11.3 0.0 100.9 0.0 0.212 TL 20.33 PV Pipe: 12 -294.0 3.260 PL 46.17 PF 5.7 12 11.3 0.0 100.9 0.0 11.3 120 FTG 3E FE 0.0 TOR 11.3 0.0 106.6 0.0 0.075 TL 76.17 PV SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 4 DATE: 2/1/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: Kelly Ranch Pre-School PIPE TAG Q(GPM) DIA(IN) LENGTH PRESS. END ELEV. NOZ. PT DISC. VEL(FPS) HW(C) (FT) SUM. NODES (FT) (K) (PSI) (GPM) FL/FT (PSI) Pipe: 13 -294.0 3.260 PL 10.83 PF 1.6 TOR 11.3 0.0 106.6 0.0 11.3 120 FTG E PE 4.7 BOR 0.5 0.0 112.9 0.0 0.075 TL 20.83 PV Pipe: 14 -294.0 3.260 PL 2.50 PF 0.9 BOR 0.5 0.0 112.9 0.0 11.3 120 FTG E PE 0.2 Ui 0.0 0.0 114.0 0.0 0.075 TL 12.50 PV Pipe: 15 -294.0 6.160 PL 6.00 PF 0.1 Ui 0.0 0.0 114.0 0.0 3.2 150 FTG E PE 0.0 U2 0.0 0.0 114.1 0.0 0.002 TL 28.82 PV Pipe: 16 -294.0 6.090 PL 98.00 PF 0.3 U2 0.0 0.0 114.1 0.0 3.2 150 FTG E PE 0.0 BFI 0.0 0.0 114.4 0.0 0.002 TL 119.58 PV Pipe: 17 -294.0 6.160 PL 6.00 PF 0.1 BF1 0.0 0.0 114.4 0.0 3.2 150 FTG E PE 0.0 BF2 0.0 0.0 114.4 0.0 0.002 TL 28.82 PV Pipe: 18 FIXED PRESSURE LOSS DEVICE BF3 0.0 0.0 120.4 0.0 6.0 psi, 294.0 gpm BF2 0.0 0.0 114.4 0.0 Pipe: 19 -294.0 6.160 PL 6.00 PF 0.1 BF3 0.0 0.0 120.4 0.0 3.2 150 FTG 2E PE 0.0 BF4 0.0 0.0 120.6 0.0 0.002 TL 51.64 PV Pipe: 20 -294.0 6.090 PL 20.00 PF 0.2 BF4 0.0 0.0 120.6 0.0 3.2 150 FTC TG PE 0.0 tJ3 0.0 0.0 120.7 0.0 0.002 TL 70.87 PV Pipe: 21 -294.0 6.090 PL 210.00 PF 0.7 tJ3 0.0 0.0 120.7 0.0 3.2 150 FTG ETG PE 6.5 SOURCE -15.0 SRCE 127.9 (N/A) 0.002 TL 282.46 PV NOTES: Calculations were performed by the MASS 7.7 computer program under license no. 27081246 granted by MRS Systems, Inc. 4792 LaVista Road Tucker, GA 30084 The system has been calculated to provide an average imbalance at each node of 0.003 gpm and a maximum imbalance at any node of 0.055 gpm. Total pressure at each node is used in balancing the system. Maximum water velocity is 29.1 ft/sec at pipe 7. SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 5 DATE: 2/1/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: Kelly Ranch Pre-School (4) PIPE FITTINGS TABLE Pipe Table Name: STANDARD.PIP PAGE: * MATERIAL: S40 HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Ell Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 1.104 2.57 6.41 2.57 6.41 7.70 1.28 12.83 12.83 6.41 1.452 3.84 7.69 2.56 8.97 7.69 1.28 12.81 12.81 7.69 6.090 14.28 30.61 9.18 32.65 10.20 3.06 28.57 28.57 30.61 6.160 15.10 32.36 9.71 34.52 10.79 3.24 30.20 30.20 32.36 PAGE: B MATERIAL: THNWL HWC: 120 Diameter Equivalent Fitting Lengths in Feet (in) E T L C B G A D N Eli Tee LngEll ChkVlv BfyVlv GatVlv AlmChk DPVlv NPTee 2.635 8.00 17.00 6.00 19.00 10.00 1.00 14.00 14.00 17.00 3.260 10.00 20.00 7.00 22.00 14.00 1.00 18.00 18.00 20.00 Q Q 0 0 C'1 0 0 0 0 C) SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 6 DATE: 2/1/2006 C:\HASS77\KELLYRANCH..SDF JOB TITLE: Kelly Ranch Pre-School C C> o 0 ("1 I0 0 11 00 LO (N U) -4 SPRINKLER SYSTEM HYDRAULIC ANALYSIS Page 7 DATE: 2/1/2006 C:\HASS77\KELLYRANCH.SDF JOB TITLE: Kelly Ranch Pre-School WATER SUPPLY CURVE 132+ I \\\\\\\ \\\\\\\\ 121+ \\\\\\\ \\\\\\\ * <-115.5 psi @ 1481 gpm Flow Test Point 110+ 99+ P 88+ R E S I S77+ U I R I E 66+ ( P I S I 55+ ) I 44+ 33+ 22+ LEGEND if I if I X = Required Water Supply I 127.90 psi @ 394.0 gpm 11+ I 0 = Available Water Supply " 129.20 psi @ 394.0 gpm : 0++-+---+----+-----+------+--------+--------+---------+-----------+ 400 600 800 1000 1200 1400 1600 1800 2000 FLOW (GPM) Materials All Internal metal parts: 300 Series stainless steel Main valve body. 300 Series stainless steel Check assembly: Noryl Flange dimension in accordance with AWWA Class D Dimensions - Weights Pressure — Temperature Temperature Range: 33°F — 110°F (5°C - 43°C) Maximum Working Pressure: 175psi (12.06 bar) Standards AWWA C511-92 Approvals W11% d > Aced 1047 864.5 Horizontal IMPOATAN7 INQUIRE WITH GOVERNINSAUTHORmES FOR LOCAL !NSTALL.4710N REQUIREMENTS Noryl@ is a registered trademark of General Electric Company. r426lill1 DIMENSIONS WEIGHTS________ in. mm A in mm C(OSY) in. mm 0 La. mm E 41. mm F in. mm 0 OL mm I. in. mm wilt Gates ft kos, wiuioulGales lbs. k(* _2½,j 37 940 16½ 416 101h 267 12½ 318 7 178 10 254 22 559 170 77 61 28 _3_.L 38 965 18% 479 10½ 267 13 330 7½ 191 10 254 22 559 205 93 65 29 _4 100 40 1016 223/4 578 10½ 267 141/2 368 9 229 10 254 22 559 270 122 67 30 6150 48½ 1232 301h 765 11½ 292 15½ 394 11 279 111h 292 271h 699 405 184 105 48 Capacity *UL Rated **UL Tested 2W ) (65mm a Psi 91 14 _______________*____** 4" (10(mm) 83 12 kft 1.3 Pd 18 I'T as 11,__________ __ i 15 E 6P .8 12 41 6 AP .6 it 28 4 .4 ___ _____ 14 2 ______ 2 3— _____ 08 _____ ________ I) 8 0 100 200 300 400gpm 0 50 100 150 200 200 300 350 450 450 500 550 600 650 700 750 gpin 0 380 760 1140 1526 IPM 171 380 510 7(0) 950 1140 1330 1520 1170 19(0) 2090 2280 2410 26502850 Iran 1.5 15 5 1.5 10 15 (0a 2.3 4.6 5)953 1.5 2.3 3 4.6 5)958 Flaw Rate Flow Rate kft psi 3" (80mm) * kPapsl 6" (150mm) -- 91 14 145 21 83 12 69 10 124 103 18 15 P 55 8 AP hfttitTi 83 12 __ __B _4-9 ' 8 284 _ II 41 6 ________ ________14 21 3 00 ______________________________ ____________ 2 00 ____ 0 100 400 83) 80° 0 ILl) 780 312) 400 512) 400 70) 80) re lOX) 11 00 1310 12)0 140)182) .Ll 2)0 780 7140 1578 1580 0 7882 2040 3420 3000 4)0) 4780 4944) 5700 mi 0 2)0 78) 4440 1000 100i, 5 7.5 70 75 15 1.5 45 fps 1.3 4.6 MPS Flow 1.5 2.3 3 46 ns Flow Rate Rote A M E S IF1.19001l FIRES WATER WORKS A Division of Watts Regulator Company www.amesfirewater.com I CERTWI) 1427 North Market Blvd. • Suite #9 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-5000SS 0507 ©Ames Co. 2005 1. Materials All internal metal parts: 300 Series stainless steel Main valve body: 300 Series stainless steel Check assembly: Noryl50 Flange dimension in accordance with AWWA Class D Dimensions - Weights .'.f°1 0 0 iT Pressure - Temperature Temperature Range: 33°F - 110°F (5°C - 43°C) Maximum Working Pressure: 175ps1 (12.06 bar) Standards AWWA C511-92 Approvals 4_ C US c(:Jus Approved 1047 WAS Horizontal IMPORTAiTh INQUIRE WITH GOVERMNGAUTHORITIES FOR LOCAL INSTALLATiON REQUIREMENTS Noryl® is a registered trademark of General Electric Company. DIMENSIONS WEIGHTS ft mm A in. mm C (OSY) in. mm I) In. mm 0 in. mm F in. mm G ill mm 5. ni mm with Gates ft k91 without Gates lbs kas 21h 65 37 940 1684 416 10½ 261 121h 318 7 178 10 254 22 559 170 77 61 28 3 80 38 965. 18% 479 10½ 267 13 330 7½ 191 10 254 22 559 205 93 65 29 4 100 40 1016 223/4 578 10% 267 141h 368 9 229 10 254 22 559 270 122 67 30 6 150 481h 1232 301A 766 11% 292 15½ 394 11 279 11½ 292 21½ 699 405 184 105 48 Capacity *UL Rated **UL Tested 2½" (65mm) Wa pit ** 91 14 4" (100mm) 83 12 ii 10 60 is 15 1 E P 55 8 ___ 12 _____ 418 _______ P . .0 e __________________ Z8 4 .08 14 2 23 50 00 o 100 200 300 400 gprn 0 50 100 150 2(8) 250 350 350 48)) 450 504) 550 600 650 760 750 gpni 0 380 18).) 1140 1520 1411) 171 380 570 760 950 1140 1330 1520 1170 19(0) 2090 2280 2470 26602850 1pm 7.5 15 IIIIN 5 7.5 10 15 2.3 4.6 11915 1.5 2.3 3 4.6 11919 Flow Rate Flow Rate kPapsi 3" (80mm) * ** kPa psi 6" (150mm) * 97 14 145 21 83 12 124 18 69 10 , AP 55 8 ± t1I 41 6 ' 284 _________________________ ________ 41 6 _____________________________________ 21 3 14 2 00 _____________________________ 00 0 1W260 20 4)0 si' 0 IfS) 0110 260 400 580 re 709 (0)) 500 IWO Itt)) 1210 120 145019.01 5019 0 500 150 1194 (520 lOW 14n 500 700 0194 1550 15002290 5040 2)40 3450) 3260 4183 4500 4940 5109 bo 7.5 iS isa 5 7.5 to is i 1.5 52 3 4.5 11901 2.3 4.6 1169 Flow Rate low Rate F AM ES IE-119OO1 FIRE &WATERWORKS A Division of Watts Regulator Company www.amesfirewater.com LPLRTTFIED I 1427 North Market Blvd. • Suite 419 • Sacramento. CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-5000SS 0507 ©Ames Co. 2005 many angles, reducing assembly effort. This sprin- kler is available in various temperature ratings (see chart on page 2) and fin- ishes to meet many design requirements. The recessed pendent should be utilized with a Model V27 recessed escutcheon which pro- vides up to V4' (19 mm) of adjustments. Sprinkler Operation The operating mechanism is a frangible glass bulb which contains a heat responsive liquid. During a fire, the ambient tempera- ture rises causing the liquid in the bulb to expand. When the ambient temper- ature reaches the rated temperature of the sprin- kler, the bulb shatters. As a result, the waterway is cleared of all sealing parts and water is discharged towards the deflector. The deflector is designed to dis- tribute the water in a pat- tern that is most effective in controlling the fire. Coverage For coverage area and sprinkler placement, refer to NFPA 13 standards. X/ ictaulic® AUTOMATIC SPRINKLER FIRE PROTECTION PRODUCTS V27, K56 Models V2703, V2704, V2707 and V2708 Standard Spray Upright, Pendent and Recessed Pendant Standard and Quick Response PRODUCT DESCRIPTION These Model V27 standard spray sprinklers are designed to produce a hemispherical spray pat- *V2707 tern for standard commer- cial applications. They are v2708 available with either stan- Recessed dard or quick response Pendent bulbs. The design Incorpo- () Q) rates state-of-the-art, heat <3> fl responsive, frangible glass See Vic bulb design (standard or publication 10.01 I V2707 for detalls.quick response) for prompt, V2708 precise operation. ui 't The die cast frame is more streamlined and attractive - than traditional sand cast Pendent . r frames. It is cast with a V2703 hex-shaped wrench boss to V2704 allow easy tightening from Upright TECHNICAL SPECIFICATIONS Models: V2703. V2704. V2707 V2708 Style: Pendent. Upright of- Recessed Pendent Nominal Orifice Size: ½" (13 miii) K-Factor: 5.6 Imp. (8,1 SI!') Nominal Thread Size: 1/2" NP'f (15 mm) Max. Working Pressure: 175 psi (1200 kPa) Factory Hydrostatic Test: 100% @ 500 psi (3450 kPa) Mm. Operating Pressure: 7 psi (48 kPa) Temperature Rating: See chart on page 2. MATERIAL SPECIFICATIONS Upright Deflector: Bronze per UNS C22000 Pendent Deflector: Bronze per UNS C51000 Bulb: Glass with glycerin solu- tion. Bulb Nominal Diameter: U Standard: 5.0 mm U Quick Response: 3,0 mm Load Screw: Bronze per UNS C65100 Pip Cap: Bronze per UNS C65100 Spring: Beryllium nickel Seal: Teflon* tape Frame: Die cast brass 65-30 Lodgement Spring: Stainless steel per UNS S30200 ACCESSORIES Installation Wrench: U Open End: V27 U Recessed: V38, V38-3 U Socket: V27 Finishes: U Plain brass U Chrome plated U White painted" U Custom painted** U Lead" 155, 200, 286SR Only: U Wax" U Wax over lead" For cabinets and other accesso- ries refer to separate sheet. NOTE: Weather resistant recessed escutcheons available upon request. " For K-Factor when pressure is mea- sured in Bar, multiply S.I. units by 10.0. Teflon is a registered trademark of Dupont Co. UL Listed for corrosion resistance in all configurations. VICTAULIC5 IS AN ISO 9001 CERTIFIED COMPANY Victaulic Company of America Victaulic Company of Canada Victaulic Europe Victaulic America Latina Victaulic Asia Pacific Phone: 1.800.PlCK.VIC (1.800.742.5842) Phone: 905.884-7444 Phone: 32.9.381.1500 Phone: 610.559-3300 Phon 65.6235.3035 Fax: 610.250.8817 Fax: 905.884-9774 Fax: 32.9.380.4438 Fax: 610.559.3608 Fax: 65.6235.0535 e.mail:pickvic@victaalic.com e-mail: viccanada@viclaulic.com email: viceuro@viclaulic.be e-mail: vical4DviclauliC.Corfl e-mail: vicap@viclaulic.com 2544 Rev.O 8103 5 Registered Trademark of Victaullc 0 copyright 2003 Victaullc Printed In U.S.A. APPROVALSILISTINGS Nominal Approved 'Temperature Ratings FIC Orifice Size K-Factor Inches Imperial Deflector Model millimeters &LA Response Type UL FM ULC NYC/MEAt CSFM § ½ 5.6 135-360 135-360 135-360 135-360 135-360 V2703 13 8,1 Standard Upright -182 51-182 57-182 57-182 57-182 ½ 5.6 135- 360 135-360 135-360 135-360 135-360 V2707 13 81 Standard Pendent 57-182 57-182 57-182 57-182 57-182 ½ 5.6 Recessed Pendent 135-360 135-200 135-360 135-360 135-360 V2707 13 Standard Up to 5/4' Adjustment 57-182 57-93 57-182 57-182 57-182 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2704 13 8,1 Quick Upright 57 -141 57-141 57 -141 57-141 57-141 ½ 5.6 135-286 135-286 135-286 135-286 135-286 V2708 13 8,1 Quick Pendent 57-141 57-141 57 -141 57-141 57-141 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 135-200 V2708 13 8.1 Quick Up to IN Adjustment 57-93 57-93 57-93 57-93 57-93 ½ 5.6 Recessed Pendent 135-200 135-200 135-200 135-200 1 V2708 13 8,1' Quick Up to %* Adjustment 57-93 5793 5793 5793 :1 Listings and approval as 01 printing. U All are approved open, except i or areas uesignatea NO "For K-Factor Wien pressure is measured in Bar, multiply S.I. units by 10, I MEA#62-99-E. § CSFM #7690-0531:112 4 RATINGS All glass bulbs are rated for temperatures from -67°F (-55°C) up to those shown in adjacent table. Temperature - °F/°C Sprinkler Victaulic Glass Nominal Maximum Temperature Part Temperature Ambient Temp. Bulb Classification Identification Rating Allowed Color Ordinary A 135 57 100 38 Orange Ordinary C 155 68 100 38 Red Intermediate E 175 150 79 65 Yellow Intermediate F 200 150 93 65 Green High - 286 141 225 - 107 Blue Extra High t K 360 182 300 149 Purple - M Open : No Bulb Standard response only. All are approved open, except for areas designated "No". - 150/65 if wax coated. ORDERING INFORMATION Please specify the following when ordering: U Sprinkler Model Number U K-Factor U Sprinkler Finish U Style U Thread Size U Escutcheon Finish U Temperature Rating U Quantity U Wrench Model Number Always read and understand installation, care, and maintenance instructions, supplied with each box of sprinklers, before proceeding with installation of any sprinklers. - - Always wear safety glasses and foot protection. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic piping products. Installation rules, especially those governing obstruction, must be strictly followed. W • Painting, plating, or any re-coating of sprinklers (other than that supplied by Victaulic) is not allowed. Failure to follow these instructions could result in serious personal injury and/or property damage. The owner is responsible for maintaining the fire protection system and devices in proper operating condition. For minimum maintenance and inspection requirements, refer to the current National Fire Protection Association pamphlet that describes care and maintenance of sprinkler systems. In addition, the authority having jurisdiction may have additional maintenance, testing, and inspection requirements that must be followed. If you need additional copies of this publication, or if you have any questions about the safe installation of this product, contact Victaulic World Headquarters, P.O. Box 31, Easton, Pennsylvania 18044.0031, 610-559.3300. 40.10-2 (6( (25 mm) Standard Pendent - V2707, V2708 (6C Standard Upright - V2703, V2704 DIMENSIONS t 2W (60 mm) Max. Hole 2* (5`1 mm) Mm. Hole ___________________________________________________________________ 11A• Typical Ceiling Tile (27 mm) (17 mm) (14 MM) WLI I 1W Finished Surface (30 mm) (43 mm) ________ __________ MAXIMUM RECESS (75 mm) MAXIMUM EXTENSION 1/f Adjustment Recessed - V2707, V2708 (Drawing not to scale) Recessed - V2707, V2708 (Drawing not to scale) AVAILABLE WRENCHES V27 Socket V38 or V38-3 Recessed V27 Open End V2707V27O8Pendent V2707, V2708 Recessed Pendent V2703, V2704 Upright 40.10-3 ---- - — In ---- -- In —s— N m \ - \ --•-n—---- In — 10' 3,0 m a 2,4 6 1,8 4- 1,2 2 0,6 0 7psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa L I DISTRIBUTION PATTERNS MODELS V2707, V2708 K5.6 STANDARD PENDENT AND RECESSED PENDENT DISTRIBUTION PATTERNS - TRAJECTORY 10' —m- 3,Om g 8'- 2,4m ' 18m \ 4 - •\\ '\ 1,2m O,m 0 2' 4' 6' 8' 10'12' 14' 0,6m 1,2m iBm 2,4m 3,0m 3,7m 4,3m MODELS V2103, V2104 K5.6 STANDARD UPRIGHT DISTRIBUTION PATTERNS - TRAJECTORY 7psi 48 kPa 15 psi 103 kPa 30 psi ------- 207 kPa 2' 4' 6' 8' 10' 12' 14' 16' 0,6m 1,2m 1,8m 2,4m 3,0m 3,7m 4,3m 4,9m NOTES: Data shown is approximate and can vary due to differences in Installation. These graphs illustrate approximate trajectories. floor-wetiing.and wall wetting patterns far these specific Victaulic FireLock Automatic Sprinklers. They are provided as information for guidance In avolditig obstruct Ions to sprinklers and should not be used as minimum sprinkler spacing rules for Installation. Refer to the appropriate NFPA National Fire Code and the authority having jurisdiction for specific information regarding obstructions, spacing limitations and area of coverage requirements. Failure to follow these guidelines could adversely affect the performance of the sprinkler and will void all Listings. Approvals and War- ranties. All patterns are symmetrical to the centerline of the waterway. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. This product shall be manufactured by Victaulic Company. All products lobe installed in accordance with current Victauiic installation/assembly instructions. Victaulic rosoivos the right to change product specifications, designs and standard equipment without notice and without incurring obligations. 40.10-4