Loading...
HomeMy WebLinkAbout5150 HEMINGWAY DR; ; FA050025; Permit9/27/22,11:19 AM FA050025 Permit Data City of Carlsbad Fire Alarm Permit 5150 HEMINGWAY Job Address: DR Permit Type: FALARM Parcel No: Lot #: 0 Permit No: FA050025 Status: ISSUED Applied 5/23/2005 Approved: 7/12/2005 Reference No.: Issued: 7/12/2005 PC #: Inspector: Project Title: KELLY RANCH PRESCHOOL FIRE ALARM PLAN CHECK & INSPECTIONS Applicant: Owner: SIMPLEX GRINNELL 9855 CARROLL CANYON RD SAN DIEGO CA 858-740-0100 r Fees ($) Add'I Fees ($) Total ($) Balance ($) 200 0 200 0 about:blank 1/1 tqcci IF/re & I Security 15implex6rinnell SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE ALARM PRODUCT SUBMITTAL PROJECT:KELLY RANCH PRESCHOOL CARLSBAD, CALIFORNIA 0 11/1/2004 REV.#: 0 PROJECT #: tycci IF/re & I Security 15implex6rinnelf SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE ALARM SYSTEM TAB# SYSTEM I FIRE ALARM 2 APPENDIX 11/1/2004 REV.#: 0 PROJECT #: tqcci / Fire & / SimplexGrinnell Security SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com FIRE ALARM SYSTEM ITEM MODEL NO. DESCRIPTION C.S.F.M. NO. A 4100-9111 FIRE ALARM CONTROL PANEL 7170-0026:251 B 2081-9275 BATTERY 18 AH N/A C 4606-9101 LCD ANNUNCIATOR 7120-0026:225 D 4090-9001 INDIVIDUAL ADDRESSABLE MODULE 7300-0026:223 4090-9002 INDIVIDUAL ADDRESSABLE RELAY 7300-0026:223 E 4098-9714 SSD PHOTO SENSOR 7272-0026:218 4098-9733 SSD HEAT DETECTOR 7270-0026:216 4098-9792 SSD ADDRESSABLE BASE 7300-0026:217 F 4099-9003 ADDRESSABLE PULL STATION 7150-0026:224 G 4098-9756 TRUEALARM DUCT DETECTOR 3240-0026:241 PAM-SD 4098-9843 RELAY MODULE 7300-1004:101 H 4906-9103 TRUEALERT VISUAL ONLY MULTI-CD 7125-0026:316 I 4906-9129 TRUEALERT AUDIBLENISUAL MULTICD 7125-0026:317 J H12/24K SYSTEMSENSOR OUTDOOR HORN 7135-1209:143 WBB WHEATHER PROOF BACK BOX N/A L 4905-9815 SYNC ADAPTER 7300-0026:315 5/19/2005 REV.#: 0 PROJECT #: 5®Simplex 4100LJ Fire Control Panels UL, ULC Listed; FM, CSFM, Addressable Fire Detection and Control and MEA (NYC) Approved* Basic Panel Modules and Accessories S I 1ui* Master Controller (top) bay: Master controller assembly with operator interface and 4100 Software Revision 11.08 Enhanced CPU with dual configuration programs, convenient service port access, and capacity for up to 2000 points System power supply (SPS) and charger (9 A total) with on-board: NACs, IDNetTM addressable device interface, and programmable auxiliary output and alarm relay Operator interface that is conveniently color coded with raised switches providing high confidence feedback Module level ground fault search locates and isolates faults to assist installation and service (with 11.03) Available with redundant CPU (requires two bays) Standard addressable interfaces include: IDNet addressable device interface with 250 points Remote annunciator module support via RUI (remote unit interface) communications port Optional modules include: MAPNET IT® or IDNet addressable interfaces that support TrueAlarm® analog sensing operation and operate with either shielded or unshielded twisted pair wiring** Panel mounted SLC quad isolators and TrueAlert® addressable notification appliance power supplies DACT, City Connect, and Network interfaces RS-232 ports for printers or maintenance terminals Alarm relays, auxiliary relays, additional power supplies, [DC modules, and NAC expansion modules Service modems, VESDA® Air Aspiration Systems interface, and coded manual station interface LED/switch modules (refer to data sheet S4100-0032) Audio amplifiers, firefighter master phones, and control modules (refer to data sheet S4100-0034) Compatible with Simplex® remotely located: TrueAlert Addressable Controllers and both Addressable and Conventional NAC Extenders 4003 Voice Control Panels and the BACpac® BACnet® portal Master controller upgrade kits are available for existing fire alarm control panels 4100U and upgrade kits are UL Listed to: UL Std. 864, Fire Detection and Control (UOJZ), and Smoke Control Service (UUKL) UL Std. 2017, Process Management Equipment (QVAX) UL Std. 1076, Proprietary Alarm Units-Burglar (APOU) UL Std. 1730, Smoke Detector Monitor (UULH) ULC Std. S527-99 Simplex fire alarm technology is protected by the following U.S. Patent Numbers: TrueAlarm analog smoke detection: 5,155468; 5,173,683 and 5,543,777. IDNet and MAPNET II addressable communications; 4,796,025. TrueAlert addressable notification; 6,313,744 and 6,426,697. SmartSync horn/strobe control; 6,281,789. 4100U Cabinets are Available with Two or Three Bays CPU provides two on-board configuration programs: Two programs allow for reduced service programming time with one active program and one reserve Downtime is reduced because the system stays running during download PC based programmer features: Convenient front panel access port for quick and easy download of site-specific programming Modifications can be uploaded as well as downloaded for greater service flexibility AND, firmware enhancements are made via software downloads to the EPROM - service personnel are not required to exchange board level components flrIt1TI Building on the established success of the 4100 Series products, the 4 100U Series offers additional operator, installation, and service features. These new features include both new hardware and new software designs that provide high performance and convenient operation, installation, and maintenance. (Additional features are found in documents referenced on page 7.) I rrnri :vI '. ir1Ir1 4100U Control Panels provide point and module capacities that are suitable for a wide range of small to medium size applications. They accept a variety of interface modules and can be configured for either Stand-Alone or Networked fire control panel operation. See pages 5 and 6 for product that is UL or ULC listed. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:251 (non-high rise) and 7170-0026:250 (high rise) for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. S4100-0031-7 10/2003 h'ArTrn :J iFllr1Y(IIi7rnis:ici.ij The Master Controller Bay (top) includes a standard multi-featured system power supply, the master controller board, and operator interface equipment. The Expansion Bays include a Power Distribution Interface (PDI) for new 4" x 5" flat design option modules and also accommodate 4100-style modules. The Battery Compartment (bottom) accepts two batteries, up to 50 Ali, to be mounted within the cabinet without interfering with module space. The following illustration identifies bay locations using a three bay cabinet for reference. 4100U Module Bay Reference Mechanical Description Optional modules are easily and quickly installed and programmed New design modules are mechanically secured in place and then electrically plugged into the PDI module reducing the need for wiring harnesses Boxes can be close-nippled; each box provides convenient stud markers for drywall thickness and nail-hole knockouts for quicker mounting Smooth box surfaces are provided for locally cutting conduit entrance holes exactly where required Mechanical Description (Continued) The latching dress panel (retainer) assembly easily r lifts off for internal access NACs are mounted directly on power supply assemblies providing minimized wiring loss, compact size, and readily accessible terminations Packaging supports traditional 4100-style motherboard with daughter cards Modules are power-limited (except as noted, such as relay modules) The NEMA 1 box is ordered separately and available for early installation Boxes, doors, and dress panels are available in beige or red (ordered separately) Doors are available with tempered glass inserts or solid, in beige or red Refer to document S4100-0037 for enclosure details rniTi'rntI I(]iT.{ The following illustration identifies the primary functions of the operator interface. Operator interface panel is directly Upload/Download Basic operator instructions Panel sounder port access (under are printed on the interface sliding cover) mounting plate I!kai mTI1uhi111!1Ivj TrueAlarm individual analog sensing with front panel information and selection access "Dirty" TrueAlarm sensor maintenance alerts, service and status reports including "almost dirty" TrueAlarm magnet test indication appears as distinct "test abnormal" message on display when in test mode TrueAlarm sensor peak value performance report Selectable service override allows authorized operators to clear alarm conditions during System Reset even if status has gone to trouble before reset occurred Module level ground fault searching assists installation and service by locating and isolating modules with grounded wiring (software revision 11.03 and higher) WALKTESTI'M silent or audible system test performs an automatic self-resetting test cycle (WALKTEST operation is protected under U.S. patent No. 4,725,818) NOTE: If optional features require software revisions other than 11.08, updates will be provided on-site by the authorized Simplex product representative. S4100-0031-7 10/2003 L! Lf I 1* Status Information. With the locking • Convenient and extensive operator information is • Convenient door closed, the glass window allows viewing of the provided using a logical, menu-driven display display, status LEDs and available operator switches. • Features include a two-line by 40-character, wide viewing Multiple automatic and manual diagnostics for maintenance reduction angle (super-twist) LCD with status LEDs and switches as shown in the illustration below. • Alarm and Trouble History Logs are available for viewing from the LCD, or capable of being printed to a LED indicators describe the general category of activity connected printer, or downloaded to a service computer being displayed with the LCD providing more detail. For the authorized user, unlocking the door provides access to • Convenient PC programmer label editing the control switches and allows further inquiry by • Password access control scrolling the display for additional detail. FIRE ALARM ACK acknowledges a Fire Alarm condition, logs the acknowledge, and silences the operator panel and all annunciator tone-alerts SIX SYSTEM STATUS INDICATOR LEDs PRIORITY 2 ACK acknowledges a Priority 2 Alarm provide system status indications in addition condition, logs the acknowledge, and silences the to LCD information, LEDs flash to indicate operator panel and all annunciator tone-alerts ULC SYSTEMS the condition and then when acknowledged, SUPV ACK acknowledges system supervisory require designating remain on until reset: conditions, logs the acknowledge, and silences the a Ground Fault Fire Alarm & Priority 2 Alarm, red LED operator panel and all annunciator tone-alerts indicator Supervisory Supervisory & Trouble, yellow LED Alarm Silenced, yellow LED TROUBLE ACK acknowledges system troubles, logs AC Power, green LED (on for normal) the acknowledge, and silences the operator panel and all annunciator tone-alerts THREE PROGRAMMABLE LEDs / ____________________________ ALARM SILENCE causes audible notification provide custom labeling, the top / 2 X 40 LCD READOUT, LED backlighted appliances to be silenced (depending on panel two LEDs are selectable as red or / during normal conditions and abnormal programming) typically after evacuation is complete and W yellow, the bottom LED is I operating conditions, provides up to 40 while alarm source is being investigated; may allow selectable as green or yellow ! characters for custom label information visible notification to continue (strobes still flashing) I FIRST ALARM DISPLAY: Operation can SYSTEM RESET restores control panel to normal when [Custom label insert J j be selected for maintained display of first all alarmed inputs are returned to normal / alarm until acknowledged 3 Waterfiow-East I I SYSTEM IS NORMAL * ______________ Waterflow-West [ 08:23:43 am WED 01-OCT-03 r ALARMS Fire Alarm Priority '- I City Fire A am ystem ap. (I ET ADDR .Jliil _ 01 Eievator Recall ,,E~iiiir Time Info d1ol Previ— I Disable . IFIVE PROGRAMMABLE 1 POINT STATUS ADDITIONAL l LCD NAVIGATION NUMERIC KEYPAD for FUNCTION SWITCHES, CONTROL KEYS: FUNCTION KEYS: CONTROL: point category and point each with a yellow LED Point Enable and Event Time Request Menu selection selection (alphabet (ipdicator ) Disable More Information Request Vertical and characters are not used at Force On or Arm Lamp Test Horizontal position this time) w Force Off or Disarm selection buttons Return On/Off or Arm/Disarm to Auto Mode S4100-0031-7 10/2003 [ir.iui,11tt1iT1Iil'1t.* The 4100U is compatible with an extensive list of 4100 Series peripheral devices including printers, CRT/keyboards, and both conventional and addressable devices including TrueAlarm analog sensors. Overview. The 4100U provides standard addressable device communications for IDNet compatible devices and accepts optional modules for communications with MAPNET II compatible devices. Using a two wire communications circuit, individual devices such as manual fire alarm stations, TrueAlarm sensors, conventional DC zones, and sprinkler waterflow switches can be interfaced to the addressable controller to communicate their identity and status. Addressability allows the location and condition of the connected device to be displayed on the operator interface LCD and on remote system annunciators. Additionally, control circuits (fans, dampers, etc.) may be individually controlled by using a relay JAM (individual addressable module). Addressable Operation. Each addressable device on the communication channel is continuously interrogated for status condition such as: normal, off-normal, alarm, supervisory, or trouble. Sophisticated poll and response communication techniques ensure supervision integrity and allow for "T-tapping" of the circuit for Class B (Style 4) operation. The device LED blinks to indicate receipt of a communications poll and is steady on to indicate an alarm (or trouble) condition. IDNet Channel Capacity. The CPU bay system power supply (SPS) provides an IDNet signaling line circuit (SLC) that supports up to 250 addressable monitor and control points intermixed on the same pair of wires. Additional IDNet circuit modules are available for 64, 127, or 250 addressable devices. MAPNET II Channel Capacity. A total of 127 addressable monitor and control points may be intermixed on the same pair of wires supporting a single MAPNET 11 signaling line circuit (SLC). Wiring Requirements for MAPNET II or IDNet Communications. Refer to the specifications chart below. Distances are for shielded or unshielded wire. Shielded wire may provide protection from unexpected sources of interference. Wiring Specifications Size 18 AWG minimum (0.82 mm2 ) Preferred Shielded twisted pair (SIP) Type Acceptable* Unshielded twisted pair (UIP) Farthest Distance from Control Up to 2500 feet (762 m) Panel to Device Total Wire Length Allowed With Up to 10,000 ft (3 km). "I" laps for Class B Wiring * Some applications may require shielded wiring. Review system with your local Simplex product supplier. ITriipAlprt Arldrps-sahip Nntificition The 4100U can be equipped with a TrueAlert Power Supply that provides three 3 A Signaling Line Circuits (SLCs) for both controlling and powering addressable notification appliances. With addressable appliances, Class B wiring can be "T-tapped" for both easier wiring and reduced wire run lengths. Extensive details concerning TrueAlert addressable notification are found on data sheet S4009-0003. Appliances are documented separately and include homs, strobes, and combination units. fT!1 Fiijjj nTIsj SI:] iT1 Addressable device communications include operation of TrueAlarm smoke and temperature sensors. Smoke sensors transmit an output value based on their smoke chamber condition and the CPU maintains a current value, peak value, and an average value for each sensor. Status is determined by comparing the current sensor value to its average value. Tracking this average value as a continuously shifting reference point filters out environmental factors that cause shifts in sensitivity. Programmable sensitivity of each sensor can be field selected at the control panel for different levels of smoke obscuration (shown directly in percent) or for specific heat detection levels. In order to evaluate whether the sensitivity should be revised, the peak value is stored in memory and can be easily read and compared to the alarm threshold directly in percent. TrueAlarm heat sensors can be selected for a fixed temperature detection, with or without rate-of-rise detection. Utility temperature sensing is also available, typically to provide freeze warnings or alert to HVAC system problems. The temperature readings can be programmed to be read in either Fahrenheit or Celsius. TrueSense® Early Fire Detection. Multi-sensor 4098-9754 provides photoelectric and heat sensor data using a single 4100U IDNet address. With revision 11 software, the panel evaluates smoke activity, heat activity, and their combination, to provide TrueSense early detection. For more details on this patented operation, refer to data sheet S4098-0024. i.i.I 'fTfl 110011i 1i Sensor Status. TrueAlarm operation allows the control panel to automatically indicate when a sensor is almost dirty, dirty, and excessively dirty. The NFPA 72® (National Fire Alarm Code®) requirement for a test of the sensitivity range of the sensors is fulfilled by the ability of TrueAlarm operation to maintain the sensitivity level of each sensor. Modular TrueAlarm sensors use the same base and different sensor types (smoke or heat sensor) and can be easily interchanged to meet specific location requirements. This allows intentional sensor substitution during building construction when conditions are temporarily dusty. Instead of covering smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. The control panel will indicate an incorrect sensor type, but the heat sensor will operate at a default sensitivity to provide heat detection for building protection at that location. S4100-0031-7 10/2003 S [uI:FTmF1,11 Master Controller & Motherboard: The master controller mounts in Slot 4 of a two slot motherboard (Slots 3 and 4 of the Master Controller Bay) and provides a standard RUI communications channel, selectable as Style 4 or Style 7, available at Slot 4 RUT communications control up to 31 remote annunciatorslMlNll)LEX® transponders per channel including the 4603-9101 LCD Annunciator, the 4602-9101 Status Command Unit (SCU), and 4602-9102 Remote Command Unit (RCU) Up to four RUI channels are supported; use up to three 4100-1291 RUT expansion modules as required Optional Service Modem 4100-6030 mounts onto the master controller board with its own on-board connections Slot 3 of the motherboard is primarily used for the 4100-6014 Network Interface Board with media modules, and secondarily can accommodate the 4100-6038 Dual RS-232 Board System Power Supply: Rating is 9 A total, including module currents Outputs are power-limited, except for the battery charger Provides system power, battery charging, auxiliary power, auxiliary relay, earth detection, on-board IDNet communications channel for 250 points, three on-board NACs, and provisions for either an optional City Connect Module or an optional Alarm Relay Module Dual rate, temperature compensated battery charger charges up to 50 Ah sealed lead-acid batteries mounted in the battery compartment System Power Supply (Continued): The charger is UL listed for charging up to 110 Ah batteries mounted in an external cabinet (refer to data sheet S2081-0012 for batteries and cabinet details) Performs battery monitor including low battery warning Provides status information to the master controller and analog values for battery voltage, charger voltage and current, actual system voltage and current, and individual NAC currents 2 A Auxiliary Power Output is selectable for detector reset, door holder, or coded output operation Auxiliary Relay is selectable as N.O. or N.C., rated 2 A @ 32 VDC, and is programmable as a trouble relay, either normally energized or normally de-energized, or as an auxiliary control Optional City Connect Module (4100-603 1, with disconnect switches, or 4100-6032, without disconnect switches) can be selected for conventional dual circuit city connections Optional Alarm Relay Module (4100-6033) provides three Form C relays that are used for Alarm, Trouble, and Supervisory, rated 2 A resistive @ 32 VDC IDNet SLC Output provides Style 4 or Style 7 communications for up to 250 addressable devices (as described on page 4) Three, 3 A On-Board NACs, conventional reverse polarity operation, selectable as Class A or Class B, with electronic control and overcurrent protection; operation is selectable for synchronized strobe or SmartSyncTM horn/strobe operation over two wires NACs can be selected as auxiliary power outputs derated to 2 A for continuous duty; the total of all auxiliary power output per SPS is limited to 5 A mE.] li.Hrnm1 maximum Master Controller and Expansion Bay Selection (Canadian models have low battery cutout) Model Model TypeiListing Description supV. Alarm 4100-9111 120 VAC Input 4100U Master Controller Assembly with LCD and operator interface, 9 A system power supply/battery charger (SPS), 250 point IDNet interface,3 NACs, auxiliary relay, and external RUI communications interface 373 mA 470m 4100-9112 English French 120 VAC Canadian ' ULC 4100-9113 4100-9211 220-240 VAC Input 1j[ 4100-9131 120 VAC Input UL 4100U Master Controller Assembly, no display, no operator interface, 9 A system power supply/battery charger (SPS), 250 point IDNet interface, 3 NACs, auxiliary relay, and external RUI communications interface 363 mA m 425 A 4100-9132 English French , ana ian 120 VAC Canadian ULC 4100-9133 4100-9230 220-240 VAC Input --- Redundant Master Controller, two bay assembly; top bay contains LCD and operator interface, 4100-9121 CPU card assembly, and 4100U, 9 A system power supply/battery charger (SPS); second bay 574 A7793mAcontains CPU card in Slot 2, and LCDand operator interface; 120 VAC, 60 Hz input;m NOTE: RUI connections require use of 4100-1291 RUI expansion modules 4100-2300 Expansion Bay Assembly; order for each required expansion bay (not required for 4100-9121) Master Controller Upgrades for Existing 4100 Series Fire Alarm Control Panels Model Description - 4100 Panel Type Details 4100-7150 Master Controller Upgrade with LCD and operator interface assembly Upgrades existing 1000 point 4100 panel to 4100-7151 Master Controller Upgrade without LCD or operator interface revision 11 4100-7152 Master Controller Upgrade with LCD, operator interface, and power supply 512 point operation 4100-2301 1 Expansion Bay Upgrade Kit for mounting 4100U style (4" x 5" modules) in existing 4100 style panels Master Controller Upgrades for Existing 4020 Series Fire Alarm Control Panel Model Description 4100-9833 4020 Master Controller Upgrade with LCD & operator interface assembly; mounts as an adjunct panel; single bay size with locking glass door and retainer; cabinet dimensions are 24" W x 22" H x 8-3/8" D (610 mm x 559 mm x 213 mm) 5 S4100-0031-7 10/2003 9 Module Selection Information CommunicationI Modules Model 4100-6014 'Description Modular Network Interface; each requires For Master Controller; mounts in Slot 3 two media modules (below) For Redundant Master Controller Size 1 Slot SUpV. 28 mA ' Alarm 28 mA 4100-6061 I Slot 28 mA 28 mA 4100-6056 Wired Media Module Select two media cards as required; mounts on 4100-6014 or 4100-6061 N.A. 55 mA 55 mA 4100-6057 Fiber Optic Media Module N.A. 25 mA 25 mA 4100-6055 Network Access Dial-in Service Modem, mounts to 4100-6014 or 4100-6061 Network Interface Card, requires telephone line connection N.A. . . m 75 A 75 A m 4100-1291 Remote Unit Interface Module (RUI); up to three maximum per control panel I Slot 85 mA 85 mA 4100-6030 Service Port Modem, local panel access only, mounts to Master Controller Module, requires telephone line connection, accesses same information as front panel port N.A. 70 mA 70 mA 4100-6031 Select one per SPS (fits on SPS) City Circuit, with disconnect switches For use with SPS only, not RPS N.A. 20 mA 36 mA 4100-6032 City Circuit, w/o disconnect switches N.A. 20 mA 36 mA 4100-6033 Alarm Relay, 3 Form C relays, 2 A © 32 VDC; for SPS or RPS N.A. 15 mA 37 mA 4100-6036 Physical Bridge, Style 4, includes 1 modem module and 2 wired modules 1 Slot 260 mA 260 mA 4100-6037 Physical Bridge, Style 7, includes 2 modem and 2 wired modules 2 Slots 304 mA 304 mA 4100-6038 Dual Port RS-232 Interface, mounts in Slot 3 or Slot 2; 3 max. RS-232 type per panel I Slot 132 mA 132 mA 4100-6045 Decoder Module 3 Slots 85 mA 163 mA 4100-6048 VESDA Aspiration System Interface 1 Slot 132 mA 132 mA 4100-9816 Master Clock Interface Module with one standard RS-232 port (see S4100-0033) 1 Slot 132 mA 132 mA 4100-6052 DACT, Point or Event Reporting; one shipped standard unless 4100-7908 is selected; maximum of 2 per system; includes two 2080-9047 cables, 14 ft (4.3 m) long with RJ45 plug on one end, spade lugs on wire ends 1 Slot( ((Y 30 mA 40 mA Expansion, System, Remote, and TrueAlert Power Supplies and Accessories* Model P. 4100-5101 Description/Listing 120 VAC UL Expansion Power Supply (XPS); 9 A output, 3 built-in ass s Size 2 Block( Supv. e( 50 mA _••J,J Alarm Y- 50 mA )••J•J••• 4100-5103 120 VAC, Canadian jj— 4100-5102 220-240 VAC 4100-5115 NAC Expansion Module, 3NACs, Class NB, mounts on XPS only N.A. 25 mA 25 mA 41005111 120 VAC UL Additional System Power Supply (SPS); 9 A power supply/charger with 250 point IDNet channel, 3 Class NB NACs, add IDNet device currents separately 4 Blocks 175 mA 225 mA 4100-5112 120 VAC, Canadian ULC 4100-5113 220-240 VAC 4100-5125 120 VAC UL Remote Power Supply (RPS); 9 A power supply/charger similar to SPS except no IDNet channel or City Circuits, will accept one 4100-6033 4 Blocks 150 mA 185 mA 4100-5126 120 VAC, Canadian ULC 4100-5127 220-240 VAC 4100-5120 120 VAC UL TrueAlert Power Supply (TPS); 3 Class B SLCs rated 3 A each for up to 63 TrueAlert addressable appliances per channel, 189 per TPS; built-in battery charger; 2A aux. power output; add device current separately, 0.2 mA standby (see S4009-0003 for additional detail) 4 Blocks 88 mA 100 mA 4100-5121 120 VAC, Canadian ULC 4100-5122 220-240 VAC UL 4100-5124 TrueAlert SLC Class A Adapter for all 3 SLCs, mounts on TPS only N.A. 7 mA 7 mA 4100-5152 12 VDC Power Option, 2 A maximum 11 Block 1.5 A maximum 4100-0156 8 VDC Converter, required for multiple Physical Bridge Modules, 3 A maximum 11 Block 1.5 A maximum 4100-0636 Box Interconnection Harness Kit (non-audio); order one for each close-nippled cabinet 4100-0638 4100 Slot Module Additional 24 VDC Harness; need when 4100 Slot module requirements exceed 2 A from SPS ) 0 Miscellaneous Accessories Model 4100-1279 Description Single blank 2" display cover, order as required (8 are required to fill a bay front) 4100-2210 Appliqué, Canadian French, 4100U Fire Control 4100-9835 Termination and Address Label Kit (for module marking); provides additional labels for field installed modules 4100-6029 Smoke Management Application Guide; required for UUKL listing 4100-6034 Door Tamper Switch with built-in addressable IDNet lAM, one per cabinet assembly if required 2081-9031 Series resistor for WSO, lDCs (NO. water flow and tamper on same circuit, wires after water flow and before tamper) 470 ), 1 W, encapsulated, two 18 AWG leads (0.82mm2 ), 2-1/2" Lx 1-3/8" W x 1" H (64 mm x 35 mm x 25 mm) Initiatina Device Circuits (lDCs Model Description Size Supv. Alarm 4100-5005 Eight zones, Class B 1 Slot 75 mA 195 mA 4100-5015 Eight zones, Class A ISlot 75 mA 195 mA * Canadian models have low battery cutout. XPS and RPS NACs operate like SPS, see page 5. Continued on next page 6 S4100-0031-7 10/2003 EI Module Selection Information (Continued) Addressable Interface Modules (refer to location reference on page 8) Model Description Supv. Alarm 4100-3101 IDNet Module, 250 point capacity With 250 IDNet devices, add 200 mA 250 mA 4100-3104 IDNet Module, 127 point capacity With 127 IDNet devices, add 102 mA 127 mA 4100-3105 IDNet Module, 64 point capacity With 64 IDNet devices, add 51 mA 64 mA IDNet Modules, Specifications for each capacity; Module without devices 75 mA 115 mA Module size = I Block Loading per IDNet device 0.8 mA I mA Model Description Supv. Alarm MAPNET II Module, 127 point capacity, add devices Module without devices 270 mA 290 mA 4100-3102 separately; Module size = 2 Slots; Loading per MAPNET II device = 1.7 mA Fully loaded module, total 470 mA 490 mA Isolator Module for MAPNET II or IDNet; converts a single connected SLC into four 4100-3103 isolated outputs selectable as Class A or Class B; up to two Isolator Modules can be 50 mA 50 mA connected to one SLC; Module size = 1 Slot Relay Modules; Nonpower-limited (for mounting in expansion bay only, refer to location reference on page 8) Model 4100-3202 Description 4 DPDT w/feedback Resistive Ratings 10A 250 VAC Inductive Ratings 10A 250 VAC Size 2 Slots Supv. 15 mA Alarm 175 mA 4100-3204 4 DPDTw/feedback 2A 30VDCNAC 1/2A 30VDC/120VAC 1 Block 18 mA 70 mA 4100-3206 8 SPDT 3A 30 VDC/120 VAC 1-1/2 A 30 VDC/120 VAC I Block 16 mA 200 mA Current Calculation Notes: To determine total supervisory current, add currents of modules in panel to base system value and all external loads powered by panel power supplies. To determine total alarm current, add currents of modules in panel to base system alarm current and add all panel NAC loads and all external loads powered from panel power supplies. [Cj iti 1 I1TT UTTI i. 11 System Power Supplies (SPS) 120 VAC Models 3.5 A maximum @ 102 to 132 VAC, 60 Hz Input Expansion Power Supplies (XPS) Power Remote Power Supplies (RIPS) 220-240 VAC 11.75 A maximum @ 204 to 264 VAC, 50/60 Hz; lrueAlert Power Supplies (TIPS) Models separate taps for 220/230/240 VAC Total Power Supply 9 A total @ nominal 28 VDC, including module currents Output switches to Power Supply Output Output Rating and auxiliary power outputs battery backup Ratings, System, Expansion, and Remote Auxiliary Power Tap 2 A maximum @ nominal 28 VDC during mains AC Power Supplies NACs Programmed failure or brownout conditions 2 A maximum per NAC, 5 A maximum total @ nominal for Auxiliary Power 28 VDC Battery capacity 6.2 Ah to 50 Ah; selectable via programming for batteries below 18 Ah; the SIPS is Battery Charger, range UL listed for up to 110 Ah battery charging for remotely located batteries System and Remote Charger Power Supply characteristics and Temperature compensated, dual rate, recharges depleted batteries within 48 performance hours per UL Standard 864; to 70% capacity in 12 hours per ULC Standard S527 Environmental Operating Temp. 32° to 120°F (0° to 49° C) Operating Humidity Up to 93% RH, non-condensing Q 90° F (32° C) maximum Additional 4100U Data Sheet Reference Subject • Enclosures Data Sheet, S4100-0037 Subject , Ml N IPLEX Transponders Data Sheet S4100-0035 LED/Switch Modules S4100-0032 Network Display Unit (NDU) S4100-0036 4100U Audio/Phone Modules S4100-0034 Remote Annunciators S4100-0038 TFX Interface Module S4100-0042 I Remote Battery Charger S4081-0002 TrueAlert Addressable Products S4009-0003 S4100-0031-7 10/2003 slot Slot Slot Slot Slot Slot Slot Slot Block A Block C Block E Block G Block B Block D Block F Block H Expansion Bay Chassis IN Mounting and CPU Bay Module Reference (* indicates supplied modules) Slot 3, one 2" card: either 4100-6014 Network Module with media cards or 4100-6038 Dual RS-232 Master Controller Bay 4100-6030 Service Modem mounts only on master controller board 4100-6031 or 4100-6032 Slot 1 Slot 2 Alarm Relay City Circuit or 4100-6033 Slot 3 9 - Door thickness [Master controller *System power supply with motherboard Exposed cabinet for semi-flush mounting 1-3/8" (35 mm) minimum HWL: Exposed door and cabinet for semi-flush _- mounting 2-3/4" (70 mm) minimum Two, 2', or one, 4' slot for one or two modules installed per the following: 4100-6052 DACT, Slot I 4100-6036 Physical Bridge, Slot 2 4100-6037 Physical Bridge (4" module) Slots I and 4100-6048 VESDA Interface, Slot I 0r2 4100-5005/5115 IDC Modules, Slot I 0r2 4100-6038 Dual RS-232, Slot 2, if Network Module is in Slot 3 Typical Expansion Bay (showina mixed module sizes) Two bay cabinet shown without retainer Knockout screw/nail holes (for Cabinet height: semi-flush (2 bay shown mounting) for reference) - j 2 Bay 40" (1016 mm) - 3 Bay =56" - - Wall board (1427 mm) reference for semi-flush mounting, 6" stud Stud I alignment markers, Leach side 6"stud [4' Door can be hung tllllllllHtltllltttltlllhllttlllatlllwltllHatlltltlltlallflUiltltlltliltlllllltttlttlltlllllu ____________ _ L [. 6-29/32" hinged left or rightj 24" (610 mm)- L175 mm) Optional semi 8-3/8(213 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made to an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. Lj .i f1i1 :!t!I rmri T rnii (:1(:1I* - Description Mounting IDNet Modules 1 Block 4, 2 A Relays NON Power-limited 1 block 4, 10 A Relays 4", 2 slots 8, 3 A Relays I block VESDA Interlace 2", 1 Slot Class B IDC 2", 1 Slot Class A IDC 2", 1 Slot MAPNET II Module 4", 2 Slots MAPNET II/IDNet Isolator 2", 1 Slot Style 4 Physical Bridge 2", 1 Slot Style 7 Physical Bridge 4", 2 Slots Decoder Module 6", 3 Slots System, Remote, or TrueAlert Power Supply Blocks E, F, G & H ONLY Expansion Power Supply Blocks G & H ONLY NAC Expansion Module On XPS ONLY Size Definitions: Block = 4W x 5" H (102 mm x 127 mm) card area Slot = 2" W x 8" H (51 mm X 203 mm) motherboard with daughter card Tyco, Simplex, the Simplex logo, M4PNET11, IDNet, TrueAlarm, SmariSync, WALKTEST, MINIPLE.X TrueAlerl, TrueSense and BACpac a"e trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. Microsoft and Windows are registered trademarks of Microsofi Corporation. VESDA is a trademark of Vision Products Pty Ltd. NFPA 72, and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). BACnet is a registered trademark of the American Society of Heating, Refrigeration, and Air Conditioning Engineers (A SHRA F). Tyco Safety Products Westminster• Westminster, MA - 01441-0001 USA S4100-0031-7 10/2003 .Simplex www.tycosafetyproducts-usa-wm.com 0 2003 Tyco Safety Products Westminstec All rights reserved. All specifications and other information shown were current at ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7165-0026:251 Page 1 of 3 CATEGORY: Control Unit (Non High-Rise) LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattem (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4100-8031, -8041, -8051, -8231, -8241, -8251, -8731, -9001, -9111, -9112, -9113,- 9121, -9131, -9132, -9133, -9211, -9230, -9600, -9601 and -9602 fire alarm control units. Power limited, automatic, manual, local, auxiliary, remote station, proprietary and central station, process monitoring, smoke control system, smoke detector monitor, emergency communication and relocation, waterfiow and sprinkler supervisory service. Suitable for releasing device service. Refer to listee's data sheet for detailed product description and operational considerations. System components: 4100-7101, -7104, -7113, -7115 4100-7105 4100-7150, -7151, -9833 4100-5005,-5015 4100-1291 4100-3102 4100-3102,-9812 4100-3103 4100-6038 4100-6014 4100-1293 4100-6052 4100-6053 4100-6031, -6032, -9827, -9828 4100-2300, -2320 2975-9407 thru-9412 4100-2101 thru -2103, -2121 thru -2123 4100-2111 thru -2113, -2131 thru -2133 2975-9422 thru -9426, -9428, -9429, 2975-9431, -9432 4100-0633, -6034 4100-9141, -9142, -9241, 9242 4100-6030, -6055 4100-5101, -5102, -5103, 4100-5111, -5112, -5113 4100-5125, -5126, -5127 4100-1288, -1289 4100-1276 thru -1287 4100-1290 4100-9610,-9611 4100-1292 4100-3115 Master Controller Assembly Redundant Master Controller Assembly Master Controller Replacements 8-Point Class A IDC Module Remote Unit Interface Module MAPNET Communication Module MAPNET II Module MAPNET/IDNET Isolator Module RS-232/2120 Communication Module Modular Network Interface Module Printer Event Reporting DACT Point reporting DACT City Module Expansion Bay Backbox Glass Door and Retainer Solid Door Enclosure Enclosure Tamper switch Network Display Unit Service Modem Expansion Power Supply System Power Supply Remote Power Supply LED/Switch Controller LED/Switch Module 24 Point Graphic I/O Module Remote Annunciator Remote LCD Display XA Loop Interface Module 0 *Rev. 04-27-04 Listing No. 7165-0026:251 Page 2 of 3 4100-3101, -3104, -3105, -9811 IDNET Module 4100-9116 Addressable IDNET Isolator 4090-9117 Addressable Power Isolator 4100-9643 Utility Cabinet 4100-0634,-0635 Power Distribution Module 4100-5152, -5153, -5154, 5155 Auxiliary Power Supply 4100-6033,-9829 Alarm Relay Card 4100-3201, -3202, -3203, -3204, -3206 Auxiliary Relay Modules 4100-0620 Basic Transponder Interlace Card 4100-6043,-6044 Converter 4100-6045 Decoder Module 4100-6054 Fiber Optic Driver 4100-5115 Expansion NAC 4100-9816 Master Clock Interface 4100-5120, -5121, -5122 True Alert Power Supply 4081-9306, -9308 Expansion Battery Charger 4100-2140 Rack Mount Bay Mounting Kit 4100-2144 Rack Mount PDM Mounting Kit 4100-0156 Eight Volt Converter 4100-0625 Local ModeTransponder Interlace Card 4601-9100,-9108,-9109,-9110,-9111 Local Mode Controller 4100-0623 Basic NetworkTransponder Interlace Card 4100-0621, -0622 Audio Riser Module 4100-6031, -6032 City Circuit Module 4100-6036,-6037 Physical Bridge Assembly 4100-6056 Wired Media Card 4100-6057 Fiber Optic Media Card 4100-9620 Analog Audio Expansion Bay 4100-9621 Digital Audio Expansion Bay 4100-1210 Analog Audio Controller Card 4100-1211, -1311 Digital Audio Controller Card 4100-1212 thru -1225, 1261, -1262 Analog Audio Amplifier 4100-1312 thru -1325, -1361, -1362 Analog Audio Amplifier 4100-1226 thru -1239, 1263, -1264 Digital Audio Amplifier 4100-1326 thru -1339, -1363, -1364 Digital Audio Amplifier 4100-1240 Audio Input Option Card 4100-1241, -1242 Message Expansion Card 4100-1243,-1244 Microphone Module 4100-1245, -1248, -1266 Amplifier Expansion NAC 4100-1246, -1249, -1267 Amplifier Class A Adapter 4100-1252, thru -1255 Audio Operator Interlace Module 4100-1270 Master Telephone Assembly 4100-1271 Remote Telephone 4100-1272 Expansion Phone Card 4100-1273 Telephone Class A Adapter 4100-5116 Expansion Signal Card 4100-1259, -1260, -1268 Constant Supervision NAC Modules 4100-1265 Degrade Fail-Safe Microphone Module 4100-6062 TFX Interlace Card *41006063 6064 Fiber Optic Modem *41009842 Fiber Modem Audio Expansion Board *Rev. 04-27-04 Listing No. 7165-0026:251 Page 3 of 3 ATlNG: 120, 220, 240 VAC primary; 24 VDC secondary INSTALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model/catalog number, electrical rating and UL label. APPROVAL: Listed as fire alarm control units suitable for high rise application for use with separately listed compatible initiating and indicating devices. Refer to listee's Installation Instructions Manual for details. These control units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. NOTE: *For Fire Alarm Verification feature (delay of the fire alarm signal), the maximum Retard/Reset/Restart period shall not exceed 30 seconds. *Rev. 04-27-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verity correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: MAY 27, 2004 Listing Expires June 30, 2005 Authorized By. DIANE K. A REND, Senior Deputy Program Manager Multi-Application Peripherals 95implex and Accessories Batteries and Chargers 2081 Series System Batteries, 6.2 Ah to 50 Ah FEATURES Rechargeable, sealed lead-acid design: - Lead-calcium grid structure - Immobilized electrolyte in absorbent separator - High reliability dual seal construction - Low maintenance, no need to add water - Low self-discharge characteristics One-piece, high impact polystyrene cell cover UL 924 recognized pressure relief valves Available in a variety of capacities DESCRIPTION Simplex rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications. They are designed with immobilized electrolyte in an absorbent separator, allowing them to provide rated capacity on the first cycle. Because of their sealed construction, packaging is allowed within the system electronics enclosure (see Figure 1, page 2). When this is applicable, the quantity of system cabinets and the battery wiring distances are both minimized. SPECIFICATIONS Nominal Voltage Rating...............................12 V/battery Discharge Rating ...... .................................. 20 Hour Rate Typical Charge/Discharge Cycles .................100 to 150 Preferred Charge Temperature Range .. .60° F to 90° F (15.6° C to 32.2° C) - These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers as listed on page 3. Contact Simplex for proper battery selection per system requirements. Sealed Lead-Acid Batteries for Panel Mounting APPLICATIONS Charging. These batteries are intended to be used with compatible Simplex battery chargers. Series Connections. These batteries are required to be connected in series to produce 24 V system voltage. Battery sets must be of identical voltage, model number, appearance, and approximately the same date of manufacture for proper operation. Testing. Battery capacity testing is recommended to be performed by using a sealed lead-acid battery tester designed to withdraw a minimum of battery charge. The preferred tester applies a variety of amplitude and duration controlled test pulses that compares terminal voltage against those predicted for the specific battery size. (Testing is available through Simplex Service.) Disposal. Battery chemicals and materials can be recycled. Refer to information shipped with the battery or on its case. Return to the battery manufacturer or to a similarly qualified battery processing facility for proper disposal. 'Dl © 2000 Simplex Time Recorder Co. All rights reserved. S2081-0006-15 6/00 qanlorl r,, .fr r'ri,r Cell case (high impact polystyrene) Inner cover Absorbent sei used to imrr e1e Lead-calciur C SEALED LEAD ACID BATTERY CONSTRUCTION DETAILS: (actual appearance will vary with battery size) Potting material, black for negative, red for positive (polarity is also clearly marked with + and -) Pressure relief valve Semi-permeable membrane separator fl Figure 1. Battery Construction Reference S2081-0006-15 6/00 page 2 BATTERY SPECIFICATIONS AND SELECTION CHART Battery Mechanical Specifications* Battery Model Aa:( Hour Width Depth Hei with Terminals Approximate Weight 2081.9272 6.2 6 1/8" (156 mm) 25/8" (67 mm) 4" (102 mm) 5.75 lbs (2.6 kg) 2081-9274 10 6" (153 mm) 4 1/16" (103 mm) 4" (102 mm) 9.2 lbs (4.2 kg) 2081-9288 12.7 6" (153 mm) 4" (102 mm) 4" (102 mm) 9 lbs (4.1 kg) 2081-9275 18 7 1/4(184 mm) 3 3/8" (86 mm) 65/8" (168 mm) 14.3 lbs (6.5 kg) 2081-9287 25 6 5/8" (168 mm) 5" (127 mm) 7" (178 mm) 19.4 lbs (8.8 kg) 2081-9271 (rectangular) 33 12 1/2" (318 mm) 3 3/8" (86 mm) 7 1/16" (179 mm) 26.6 lbs (12.1 kg) 2081-9276 (square) 33 7 3/4(197 mm) 5 1/4" (133 mm) 6 3/4" (171 mm) 26.5 lbs (12 kg) 2081-9296 50 9 1/2" (241 mm) 5 1/2" (140 mm) 87/8" (225 mm) 41.8 lbs (19 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the chart below for panel mounting compatibility. These batteries are 12 V each and series connected for 24 V system use. When installed in a fire alarm control panel, they are to be of identical voltage, appearance, model number, and approximately the same date of manufacture. Battery Selection Chart for Fire Alarm Control Panel Mounting - Battery Ah, 20 Simplex Control Panel Series (see legend and notes below) Model Hour Rate 4003 4004 4005 4009 4010 4020 4100/4120 (2, 4 or 6-Unit) (2, 4 or 6-Unit) 2081-9272 6.2 Yes 2081-9274 10 Yes -- 2081-9288 12.7 Yes Yes Yes Yes Yes 2081-9275 18 Ext Note 1 2081-9287 25 Ext Yes Ext 2081-9271 (rectangular) 33 - Note 3 Note 2 Ext 2081-9276 (square) 33 Ext Yes 2081-9296 (Note 4) 50 Ext Yes = Can be placed in the respective equipment cabinet Ext = External battery cabinet required, refer to selection chart on page 4 Shaded area Not applicable NOTES: 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries, but will not allow bottom entry conduit. 4020 Cabinets will accommodate 2081-9271, 33 Ah batteries, but will not allow bottom entry conduit. . 3. Use 4081 series companion cabinet and charger, refer to page 4. Refer to individual fire alarm control panel product data sheets for additional battery application information. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above. Contact Simplex for proper battery selection per system requirements. S S S2081-0006-15 6/00 page 3 EXTERNAL BATTERY CHARGER AND CABINET REFERENCE External Battery Cabinets Externally Mounted Battery Battery Cabinets without Chargers Battery Ah, 20 Cabinets with Chargers (connects to charger in panel) Model * Rate 4081 2081-9301 .2081-9303. Series 2081-9270 2081-9281 2081-9282 4009-980 1 4009-9802 2081-9275 18 Yes Yes Yes 2081-9287 25 2081-9271 Yes 33 2081-9276 2081-9296 50 Yes * Batteries smaller than those listed are normally mounted in the product cabinet. ** Refer to Simplex data sheet S2081-0002 for additional information on these remote battery cabinet/charger products. t Refer to Simplex data sheet S4081-0001 for additional information. Yes = Can be placed in the respective equipment cabinet Shaded area = Not applicable External Battery Cabinet Specifications I Model Description Color Dimensions 2081-9281 2-Unit, 4100 style cabinet without charger, with solid door and battery shelf, primarily intended for 50 Ah batteries Beige 25 3/4" W x 20 3/4" H x 6 3/4" D (654 mm x 527 mm x 171 mm) 2081-9282 Red 2081-9270 External battery cabinet without charger Red 26 1/2" W X 12" H x 12" D 2081-9301t External battery cabinet with charger (673 mm x 305 mm x 305 mm) 2081-9303t External battery cabinet with charger and with meters for voltage and current 4009-9801 External battery cabinet without For up to 18 Ah 16 1/4" W x 13 1/2" H x 4 1/8" D charger, with solid door and battery batteries Beige (413 mm x 343 mm x 105 mm) harness, for close-nippled mounting For up to 33 Ah 25 3/4" W x 20 3/4" H x 4 1/8" D 4009-9802 to fire alarm control panel cabinet batteries (654 mm x 527 mm x 105 mm) 4081 Companion cabinet and charger for For up to 50 Ah Available22 in beige 1/2" W x16 3/4" H x 8 3/8" D Seriestt the 4010 fire alarm control panel batteries or red (572 mm x 425 mm x 213 mm) t Refer to Simplex data sheet S2081-0002 for additional information. tt Refer to Simplex data sheet S4081-0001 for additional information. S Simplex and the Simplex logo are registered trademarks of the Simplex Time Recorder Co. S2081-0006-15 6/00 ELSimplex Westminster, Massachusetts 01441-0001 U. S. A. Offices and Representatives Throughout the World Visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. C 401 £Simplex Multi-Application Peripherals and Accessories UL, ULC Listed; CSFM, FM, 4606-9101 LCD Annunciator and MEA (NYC) Approved* for the 4010 Fire Alarm Control Panel Remote LCD annunciator for use with the Simplex 4010 fire alarm control panel LCD readout provides: Two lines of 40 characters each Wide viewing angle, super-twist design LED backlighting Control switches and status LEDs for: Alarm, supervisory, or trouble acknowledge Alarm silence System reset Three programmable LED indicators: Two LEDs are selectable as red or yellow One LED is selectable as green or yellow With provisions for custom labeling Information is transmitted over one twisted, shielded pair (Simplex N2 communications) Tone-alert sounder provides local audible indication Lamp and LCD are functionally tested each time keyswitch is switched on Mounts flush on standard 6-gang electrical box Mounting and trim options: Surface mount box model 2975-9217 (ordered separately) Brushed aluminum trim model 4603-9111 (ordered separately) * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7120-0026:225 for allowable values and/or conditions concerning material presented in this document It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for he latest status. 4606-9101 LCD Annunciator Description The Simplex 4606-9101 LCD Annunciator provides remote annunciation using an 80 character, back-lit, alphanumeric, LCD readout. Information is presented in clear, descriptive English language and includes: point status (alarm, trouble, etc.), alarm type (smoke detector, manual station, etc.), number of system alarms, supervisory conditions, troubles, and custom location labels up to 40 characters long. Communications require a single twisted, shielded pair and can also support the 4605 Series 24 I/O module on the same wire pair (up to six devices total). Alarm, Supervisory, and Trouble conditions are also indicated by dedicated LEDs and a tone-alert audible indication. Each condition has a dedicated acknowledge push-button switch that silences the tone-alert but leaves the LED on until all conditions in that category are restored to normal. Repeated operation of the appropriate acknowledge switch will scroll the LCD display showing activity in the sequence of occurrence. The internal tone-alert also sounds to indicate the operation of any of the push-button switches. Operation All switches on the annunciator are controlled by the "ENABLE" key switch with a key that is removable only in the disabled position. When enabled, notification appliances can be deactivated by pressing the "ALARM SILENCE" switch. Pressing the "SYSTEM RESET" switch restores the system to normal operation. When system activity is normal, the LCD displays the time, date, and "SYSTEM IS NORMAL." © 2000 Simplex Time Recorder Co. All rights reserved. S4606-0001-3 6/00 4606-9101 Operator Information 2 X 40 LCD READOUT, LED backlighted during normal conditions and abnormal operating conditions. FIVE STATUS INDICATOR LEDs provide system status indications in addition to LCD information. LEDs flash to indicate the condition and then when acknowledged, remain on steady until reset. THREE PROGRAMMABLE LEDs each with custom labeling pocket 0/ I I ** CVTPR IC ktf'DRiIAI ** L I12:02:15pm Mon 12-Jun-00 MI r11T S ALARM ACK acknowledges a Fire Alarm condition and silences the panel and all annunciator tone-alerts. SUPV ACK acknowledges system supervisory conditions and silences the panel and all annunciator tone-alerts. TROUBLE ACK acknowledges system troubles and silences the panel and all annunciator tone-alerts. CONTROL ENABLE KEY SWITCH controls all switch functions. Key is removable only in disabled position. I I SYSTEM RESET restores control panel to normal L when all alarmed inputs are returned to normal. ALARM SILENCE causes audible notification appliances to be silenced, used after evacuation is complete and while alarm source is being investigated. S Simplex Time Recorder Co. 2 S4606-0001-3 6/00 4606-91 01 LCD Annunciator Specifications is General Operating Specifications Voltage 18.9 to 32 VDC, system supplied backlighting is on) Normal Operating Current diattery backup, LED backlighting is turned off after 30 seconds Battery Standby Current without switch ivity) Alarm Current 140 mA maxim1'm (LED backlighting is on and tone-alert is sounding) Operating Temperature Range to 49° C) Operating Humidity Range up to 93% RH, non-condensing at 100° F (38° C) Communications Type N2 external annunciator communications line from 4010 Fire Alarm Control Panel Capacity Up to 6 annunciator modules total, 4606-9101 or 4605 series, 24 point I/O modules Communications Single twisted, shielded pair, 18 AWG Wiring Requirements Power and Earth 18 to 12 AWG wires for 24 VDC system power and Earth ground for electical box (ground per local code) Mounting Information Trim Dimensions 41/2" H x 1 13/16"W (114 mm x 300 mm) Assembly Depth 1 5/16" (33 mm), 1 1/2" at terminal block location (38 mm) Standard Trim Finish Steel, painted beige 4603-9111, Optional Trim Brushed aluminum (ordered separately) Trim Hardware Supplied with both slotted and tamper resistant screws Six-gang box, 2 1/2" (64 mm) deep minimum Masonry boxes RACO # 960, 2 1/2" deep or RACO # 965, 3 1/2" (89 mm) deep or equal Single gang boxes Six, single gang boxes, 3 1/2" (89 mm) deep minimum, RACO # 600 or equal Boxes for Flush Mounting (supplied by others) Conduit entrance is box dependent, refer to additional Box selection note mounting information on page 4 and Installation Instructions 574-188 2975-9217, Surface Mount Box Option* (ordered separately) Dimensions 12" Wx45/8"Hxl 3/4"D(305mmx117mmx44mm) Finish Painted steel, ivory finish * Reference Wiremold box number V5748-6. Simplex Time Recorder Co. 3 S4606-0001-3 6/00 Mounting Information Flush Mount Ganged Boxes: Use 6-gang box, 3 1/2" (89 mm) mm. depth, RACO # 590 using knockouts 2 1/2' from front, or RACO # 600 using side knockouts or rear cable clamps, or equal (supplied by others) Flush Mount Masonry Box: Use 6-gang box, RACO # 960, 2 1/2" deep -... (64 mm) using top or bottom knockouts, or RACO # 965, 3 1/2" (89 mm) deep, using knockouts 2 1/2" from front, or equal (supplied by others) Surface Mount Box: 0 Simplex model 2975-9217 (ordered separately) U °U U 0U 0 U ° 0 0 0 0 0 , ~' 0 = 0 = Trim plate -tI-'- 0 Wiring Reference Terminal block access at rear of enclosure, this side Annunciator Assembly NOTE: Enclosure extension into box is 10" W x 2 5/8" H x 1 5/16" D, 1 1/2" deep at terminal block access, offset to left (254 mm x 67 mm x 33 mm, 38 mm), select conduit entry accordingly. El Interconnection Wiring: Communications require a single 18 AWG twisted, shielded pair. Power requires two, 18 to 12 AWG wires for 24 VDC system power, plus Earth Ground to each electrical box. Refer to Installation Instructions 574-188 for additional wiring specifications. \ 61 LCD Annunciators 4010 Fire Alarm Control Panel S Simplex and the Simplex logo are registered trademarks of Simplex Time Recorder Co. in the U.S. and other countries. Wiremold is a trademark of The Wiremold Company - S4606-0001-3 6/00 5 Sun Iei Westminster, Massachusetts 01441-0001 USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE QISTING No. 7120-0026:225 Page 1 of I CATEGORY: Annunciators LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Model 4606-9101 remote LCD annunciator and Model 4605-8401 24 point I/O module. Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 24 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, product number, electrical rating and UL label. PPROVAL: Listed as annunciator and accessory for use with Simplex's separately listed fire alarm control units. *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 27, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager £LSimplex Multi-Application Peripherals UL, ULC Listed; FM, CSFM, MAPNET Il® and lDNetTM Communicating Devices, and MEA (NYC) Approved* Individual Addressable Module (lAM) 4090-9001 MAPNET II or IDNet addressable communications supply both data and power over a single wire pair to provide**: Supervised Class B monitoring of normally open, dry contacts Total wiring distance from IAJVI to supervision resistor(s) of up to 500 ft (152 m) Monitored connection is compatible with Simplex 2081-9044 Overvoltage Protectors for outdoor or electrically noisy applications Compatible with Simplex: Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET II communications Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation (requires mounting bracket, ordered separately) Provides current limited monitoring (for use with IDNet communications): To monitor tamper switch (trouble) and waterfiow switch (alarm) on same circuit using one point Multiple operation modes are available and are selectable at the control panel: Contact closure status can be tracked Momentary contact closure conditions can be latched, such as from rate-of-rise heat detectors UL listed to Standard 864 This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 1300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for the latest status. MAPNET II and IDNet addressable communications designs are protected by U.S. Patent No. 4,796,025. 4090-9001 Supervised lAM (shown approximately full size) r i nt ie The 4090-9001 is an individual addressable module (JAM) with both power and communications supplied by a two-wire MAPNET II or IDNet circuit. It provides location specific addressability to a single initiating device (such as single station smoke detector alarm contacts or heat detector contacts) or multiple devices at the same location by monitoring normally open dry contacts and the wiring to an end-of-line resistor. Closure of the monitored contacts initiates an alarm or other response as programmed at the fire alarm control panel. An open in the monitored circuit wiring will cause a trouble to be reported. Selections can be made at the control panel to maintain the alarm condition if the initiating device contacts are momentary, such as from a rate-of-rise heat detector, or to track the device contact status (not applicable with 2120 CDT). For use with IDNet communications only, the 4090-9001 can sense normal, open circuit, short circuit, and current limited conditions. With the proper end-of-line and current limiting resistors, dual functions such as tamper switch and waterfiow switch monitoring can be determined and communicated by a single addressable point. © 2000 Simplex Time Recorder Co. All rights reserved. S4090-0001-4 8/00 I 7T rrr rtri lAM Module Model Number Description 4090-9001 Suoervised lAM module Optional Trim Plates and Mounting Bracket Model Number Description 4090-9806 Trim plate with LED viewing window, requires 4090-9810 For semi-flush mounted box 4090-9807 mounting bracket, includes mounting screws For surface mounted box 4090-9810 Mounting bracket, mounts AM to electrical box and provides screw holes for trim plate, required for optional trim plates Electrical Power and Communications MAPNET II or IDNet, auto selected, 1 address per lAM Input Requirements o , c cts Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire Supervision Resistor 6.8 kl), 1/2 W NOTE: Refer to installation instructions 574-331 and field wiring diagrams Resistors for Current Limited Operation an 1.8 k12 d 47 k 1/2W 841-804 and 842-073 for additional (for use with IDNet communications only , information. Wiring Distances 500 ft (152 m) maximum without protectors Distance from lAM to Contacts 400 ft (122 m) maximum with 2081-9044 Overvoltage Protectors Wiring Distance, MAPNET II or IDNet, 2500 ft (762 m) maximum from fire alarm control panel per Channel 10,000 ft (3048 m) maximum total wiring distance (including T-Taps) Mechanical Dimensions 1 9/16"W x 3/4" H x 1/4" D (40 mm x44 mm x32 mm) Housing Material Black thermoplastic Temperature Range 32° to 120° F (00 to 49° C) intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Simplex Time Recorder Co. 2 S4090-0001-4 8/00 I rirni rnii rni.ii . r1 . 4090-9001 IDNet Field wiring shown supervised lAM for reference U44 I 0A[: II iJ1 LED viewing port I ItU' 00 DOD IV II Single gang electrical o box 2 1/2 (64mm) minimum depth (supplied by others) Address setting under resealable label S Single gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) Mounting Reference, Single Gang Blank Cover Plate 41/4 I (108 mm) Light pipe for I LED viewing ________ 21/2" __ (64 mm) 4090-9806, Trim plate for semi-flush mounted box 2 13/16 I (72 mm) 4090-9807, Trim plate for surface mounted box 4090-9810 Mounting bracket, ordered separately 0 NOTE: These mounting plates require mounting bracket 4090-9810. Optional Trim Plates and Mounting Bracket for Visible LED Simplex Time Recorder Co. 3 S4090-0001-4 8/00 S S Simplex, the Simplex logo, MAPNET II, and IDNet are either tradenwrkc or registered tradenwrks of Simplex Time Recorder Co in the U.S. and/or other countries. S4090-0001-4 8/00 5Sirriplex Westminster, Massachusetts 01441-0001 USA visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. 4090 Series IDNet Relay lAM Package (shown approximately 1/2 size) cifiitir (Refer to Installation Instructions 574-184 for additional information.) Communications 4010 4 ss per Relay lAM Power cpPDedbY IDNet communications Relay lAM Contacts 2 A @ 24 VDC, for transient Power-Limited Rating suppressed loads 1 A @ 24 VDC for inductive loads Nonpower-Limited Rating 1/2 A @ 120 VAC, for transient suppressed loads Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2 ) Up to 2500 ft (762 m) from fire alarm control panel Up to 10,000 ft ( 3048 m) total wiring IDNet Wiring Reference distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4-1/8" H x 4-1/8" W x 1-3/8" D (105mmx 105mmx35mm) Housing Material Black thermoplastic Mounting Plate Material Sheet metal, galvanized Temperature Range 32° to 120° F (0° 10490 C), intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) *0 IDNet addressable communications are protected by U.S. Patent No. 4,796,025. i®SimpIex Multi-Application Peripherals S UL, ULC Listed; FM, CSFM, lDNetTM Communicating Devices and MEA (NYC) Approved* Model 4090-9002 Relay lAM I1!I(.1 IDNet addressable interface modules** for use with Simplex® models 4010 and 4100U fire alarm control panels 4090-9002, Individual Addressable Relay Module (Relay lAM): A single addressable point provides control and status tracking of a Form "C" contact Low power latching relay design allows IDNet communications to supply both data and module power Compact, sealed construction: Enclosed design minimizes dust infiltration Mounts in standard 4" square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 Dscrintinn IDNet Relay lAMs allow fire alarm control panels to control a remotely located Form "C" contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. r Model Description 01~4090-9002 Relay lAM Optional Trim Plates Model Description 4090-9801 Trim plate with LED I For semi-flush viewing window, includes mounted box mounting screws; painted I For surface 4090-9802 beige mounted box . * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. S4090-0002-5 4/02 Relay lAM Mounting Information Address setting under resealable label 4(102mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for S use when LED is not required to externally viewed (supplied by others) Mounting Reference, Double Gang Blank Cover Plate IN 4-9/16" (116 mm) © © © ill,, Light pipe for LED viewing (109 mm) 111 © © 4-5/16" (109 mm) 4090-9802, Trim plate for surface mounted box © © —4-9/16" (116 mm)- 4090-9801, Trim plate for semi-flush mounted box Optional Trim Plates for Visible LED S Tyco, Simplex, the Simplex logo, and ID/Vet are trademarks of Tyco international AG or its affiliates in the U.S. and/or other countries. U.Simplex TEPG-US• 91 Technology Drive• Westminster, Massachusetts • 0144 1-0001 • USA S4090-0002-5 4/02 © 2002 TEPG-US (a Tvco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:223 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattem (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4090-9001, *901.5p, *9001uP and *..9051 Supervised [AM Monitor Module; 4090-9002, *9002TSp and *..9002up lAM Relay Module; 4090-9106, *9106TSp and - 9106TTP Class "A" ZAM Initiating Module; 4090-9101, *..9101T5P and *..91O1 UP Class "B" ZAM Initiating Module; and 2190-9173 Two-Point I/O Module. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 24VDC 30 VDC for Models 4090-9002 series INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. JIARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as control unit accessories for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 09-25-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: APRIL 61 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager BSimplex UL, ULC Listed; FM, CSFM, and NYC, MEA Approved* TrueAlarm® Analog Sensing TrueAlarm Analog Sensors - Photoelectric, Ionization, and Heat; Compatible Bases and Accessories imin1JI(*U TrueAlarm® analog sensing provides digital transmission of analog sensor values via MAPNET Il® or lDNetTM, two-wire comm unications** Fire alarm control panel provides: Individual sensitivity selection for each sensor Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allowing accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check that verifies sensor integrity Automatic environmental compensation Display of sensitivity directly in percent per foot Multi-stage alarm operation Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors: •• Seven levels of sensitivity from 0.2% to 3.7% Heat sensors: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Ionization smoke sensors*: Three levels of sensitivity; 0.5%, 0.9% and 1.3% For use with Simplex®: 4010, 4020,4100, and 4120 Series control panels Universal Transponders and 2120 TrueAlarm CDTs equipped for MAPNET H operation Magnetic test feature Functional and architecturally styled chamber enclosure: Louvered design enhances smoke capture by directing flow to chamber Entrance areas are minimally visible when ceiling mounted Optional accessories include remote LED alarm indicator and output relays UL listed to Standard 268 . * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Refer to page 4 for ULC listing status. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement that is digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor's present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor's average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base's LED pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base's LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlami analog sensors and MAPNET II and IDNet communications are protected by one or more of the following U.S. Patents: 5,155,468: 5,173,683: 5,543,777; 5,400,014; 5,552,765: 5,552,763:4,796,025; DES. 377,460. S4098-0019-8 12/01 TrueAlarm Sensor Bases and Accessories Base mounted address selection: Address remains with its programmed location Accessible from front (dipswitch under sensor) Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design Magnetically operated functional test Mounts on standard outlet box IT1ii.] M* 4098-9792, Standard sensor base 4098-9789, Sensor base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (unsupervised) 4098-9791, Sensor base with supervised relay driver output (not compatible with 2120 CDT): Relay operation is programmable and can be manually operated from control panel Use with remote mount 2098-9737 relay Also includes wired connections for remote LED alarm indicator or 4098-9822 relay KT] 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4" square electrical box and for surface mounting to 4" octagonal box Can be used for cosmetic retrofitting to existing 6-3/8" diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box ALARM (shown in illustration to right) 0 øSiiipex I i F1IFT TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric, ionization, or heat sensors. Each sensor's output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. iviouriurly rcejererice Electrical Box Requirements: (boxes are by others) Without jg: 4' octagonal or 4" square, 1-1/2" deep; single gang, 2' deep üthI: 4' octagonal 0r4' square, 1-1/2" deep, with 1-1/2" extension ring 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Surface mount reference'-... irdM I I i-0001i 1-1/2" (38 mm) minimum box depth Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess -------------------------------------------------- 2098-9737 Relay (mounts in 4098-9822 Relay (mounts base electrical box or remotely) in base electrical box) Relay Size: 2-1/2"X 1-112" X 1(3.75 cubic inches) (64 mm 38 mm X 25.4 mm) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. 6-3/8" (162 mm) II 4098-9832 Adapter Plate, required for 1/4" mounting to surface mounted boxes (6.4 mm) and E sauare flush box I 4-7/8" (124 mm) 15/16" (24 mm) L 0 TrueAlarm Bases 4098-9789, -9791, & -9792 S4098-0019-8 12/01 o TrueAlarm Sensors I'k'iI4u Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Listed to UL Standard 521 for 60 ft (18.3 m) spacing for 135° F (57.20 C) alarm, and 40 ft (12.2 m) spacing for 155° F (68° C) alarm Smoke Sensors: • Photoelectric or ionization technology sensing • 360° smoke entry for optimum response [iIe1:)j*I :rII1d.] TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° Q. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° Q. This feature can provide freeze warnings or alert to HVAC system problems. (Refer to specific panels for availability.) 1. 4-7/8' (124 mm) Ti LED status indicator 2-3/8" (60 mm) U11U.NIFAENUMI Me- TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. The sensor head design provides 3600 smoke entry for optimum response to smoke from any direction. A built-in screen keeps insects from entering the smoke chamber. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. I.' 4-7/8' (124 mm) P1 4098-9714 Photoelectric Sensor with Base I11e7ay [.1i1MlIiII]iM.] TrueAlarm Ionization sensors use a single radioactive source with an outer sampling ionization chamber and an inner reference ionization chamber to provide stable operation under fluctuations in environmental conditions such as temperature and humidity. Smoke and invisible combustion gases can freely penetrate the outer chamber. With both chambers ionized by a small radioactive source [Am 241 (Americium)], a very small current flows in the circuit. The presence of particles of combustion will cause a change in the voltage ratio between chambers. This difference is measured by the electronics in the sensor base and digitally transmitted back to the control panel for processing. Three levels of sensitivity are available for each ionization sensor: 0.5, 0.9, and 1.3% per foot of smoke obscuration. I'.._4-7/8" (124 mm) T OILED status :indicator 2-1/8 (54 mm) 4098-9733 Heat Sensor with Base 4098-9717 Ionization Sensor with Base • WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Ji]I[1([i)iU Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide. For detailed application information, refer to 4098 Detectors, Sensors, and Bases Application Manual (5 74-709). S4098-0019-8 12/01 lTry F11 iwIflFTIIFIiU TrueAlarm Sensor Bases Model Description I Compatibility Mounting Requirements 4098-9792 (C) I Standard Sensor Base, no options I Sensors 4098-9714, -9733, & -9717 S 4" octagonal or 4" square box, 1-1/2" mm. depth; or single gang box, 2" mm. depth 4" octagonal or 4" square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. Mounting Requirements Refer to base requirements Mounting Requirements Remote Mounting requires 4" octagonal or 4" square box, 1-1/2" minimum depth Base Mounting requires 4" octagonal box, 2-1/8" deep with 1-1/2" extension ring Sensor Base with connections for 4098-9789 (C) Remote LED Alarm Indicator or Unsupervised Relay Sensor Base with connections for Supervised Remote Relay and 4098-979 1 (C) connections for Remote Alarm Indicator or Unsupervised Relay TrueAlarm Sensors Model Description ...... 4098-9714 (C) Photoelectric Smoke Sensor 4098-9717 (C) Ionization Smoke Sensor 4098-9733 (C) Heat Sensor TrueAlarm Sensor/Base Accessories Model Description 2098-9737 I Supervised Relay, mounts remote or in base electrical box Sensors 4098-9714, -9733, & -9717 2098-9808 remote LED alarm indicator or 4098-9822 relay Sensors 4098-9714, -9733, & -9717 2098-9737 remote relay (supervised) 2098-9808 remote alarm indicator or 4098-9822 relay (unsupervised) Compatibility Bases 4098-9792, 4098-9789, and 4098-9791 Compatibility For use with 4098-9791 base 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Single gang box, 1-1/2" minimum depth Relay, tracks base LED status Bases 4098-9789 and 4098-9791 4098-9822 (C) (unsupervised, mounts only in base 4" octagonal box, 2-1/8" deep with 1-1/2" electrical box)extension ring Required for surface or semi-flush 4098-9832 Adapter Plate Bases 4098-9792, -9789, & -9791 mounted 4" square box and for surface mounted 4" octagonal box Refer to publication 4098 Detectors, Sensors, and Bases Application Manual (574-709) for additional information. ULC listed model numbers are designated by (C) and require a "C" suffix such as 4098-9794C. General Operating Specifications Communications and Sensor Supervisors' Power ( M)PNET II or IDNet, auto-select, 24-40 VDC w/data, 400 LIA typical, 1 address per base Communications Connections Remote LED Alarm Indicator Current 1 to cu rr Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG UL Listed Temperature Range 32° to 100° F (0° to 38° C) Operating with 4098-9717 or 4098 -9733 Temperature Range with 4098-9714 32° to 122° F (0° to 50° C) 15° to 122° F (-9° to 50° C) Humidity Range 10 to 95% RH Smoke Sensor 4098-9714, Photoelectric Sensor Ambient Ratings 4098-9717, Ionization Sensor Air velocity is 0-2000 ft/min (0-610 m/min) Air velocity is 0-100 ft/min (0-30 m/min); Altitude is up to 8000 ft (2.4 km) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 pA, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789 and 4098-9791 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply Tyco, Simplex, the Simplex logo. TrueAlarm. MAPNET 11, and IDNet are trademarks of T,vco International Services AG or its affiliates in the U.S. and/or other countries. NFPA 72 is a registered trademark of the National Fire Protection Association (NFPA). B.Simplex Westminster, Massachusetts 01441-0001 USA www.simplexnet.com S4098-0019-8 12/01 © 2001 Simplex Time Recorder Co. DBA TEPG-US (a Tyco company). All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. S S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM is LISTING SERVICE LISTING No. 7272-0026:218 Page 1 of 1 CATEGORY: Photoelectric Smoke Detector LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models 4098-9714, *.9714Tsp *971411p 9754 *97545p and *9754TTp analog photoelectric type smoke detectors. Units are intended for use with smoke detector bases Models 4098-9789 *978915P *9789up -9791, *9791TSp *9791TTp -9792, *..9792Tsp *979211P, 9793, *9793TSP, *9793TTP, 9794, -9794TSP and *9794TTp (CSFM Listing No. 7300-0026:217). Models 4098-9714, *9714Tsp and *9714up are listed for use with Models 4098-9750, - 9751, -9752 and -9753 duct detector units (CSFM Listing No. 3240-0026:220) and Models 4098-9755, *..9755TSp and *9755up duct detector units (CSFM Listing No. 3240- 0026:241). Models 4098-9754, *975415p and *9754UP analog photoelectric type smoke detectors employ an integral supplemental heat sensor (1350 F fixed temperature and 1200 F rate of rise). This heat sensor is intended for use as a supplemental device to the smoke detector and is not intended for use in lieu of required heat detectors. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. Model 4098-9714 with Model 4098-9751 is suitable for installations inside air ducts with air velocities between 0-2000 fpm. MARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as photoelectric smoke detectors for use with Simplex's separately listed Models 4100, 4010, 4020 and 4120 series fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 05-11-04 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: MAY 11f 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE S LISTING No. 7270-0026:216 Page 1 of 1 CATEGORY: Heat Detector LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 *FA)( (978) 731-8881 DESIGN: Model 4098-9733 electric combination rate compensated, fixed temperature, and rate of rise heat detector. Unit intended for use with models 4098-9789, -9791 or -9792 detector base (CSFM Listing No. 7300-0026:217). Refer to listee's printed data sheet for additional detailed product description and operational considerations. RATING: 135°F and 155°F INSTALLATION: In accordance with listee's printed installation instructions, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical/temperature ratings and UL label. S APPROVAL: Listed as heat detector for use with separately listed Simplex's 4100, 4010, 4020 and 4120 series fire alarm control units. *Rev. 05-13-2003 LL This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or , recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: APRIL 6, 2004 Listing Expires June 30, 2005 5 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:217 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models 4098-9789, -9789E, *978915P *9789up -9791, -9791E, *9791Tsp *9791TTP - 9792, -9792E, *..9792Tsp *9792UP -9793, -9793E, *9793Tsp *..9793TTp 9794 * 97941SP, *..9794up 9795 *..9795Tsp *9795TTp -9796, *9796Tsp and *9796TTp smoke detector bases. These bases act as an interface between the sensor and the MAPNET controller. Bases are intended for use with the following units: *Models 4098-9714 series *photoelectric smoke detector (CSFM Listing No. 7272-0026:218); Model 4098-9717 *ionization smoke detector (CSFM Listing No. 7271-0026:231); and Model 4098-9733 (heat detector (CSFM Listing No. 7270-0026:216). Models 4098-9795, *9795Tsp *9795TTp - 9796, *..9796Tsp and *.9796up are only intended for use with Model 4098-9754 *photoelectric smoke detector. Refer to listee's printed data sheet for additional detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances 0 and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating, and UL label. APPROVAL: Listed as detector bases for use with listee's separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. Models 4098-9794, *9794TSp *..97941Tp 9795 *9795TSp and *9795up employ a sounder, which is also suitable for use as a fire alarm audible signaling device. These base/sounders CAN NOT produce the temporal code pattern in accordance with NFPA 72, 1999 Edition. If this temporal code is required, the sounder/base unit must be used with the control unit that can produce the temporal pattern. *Rev. 05-11-04 c This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 11, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Multi-Application Peripherals MAPNET Il® or lDNetTM Communicating Devices Addressable Manual Stations Ii 4099-9001 Addressable Manual Station (front and side view) 4099-9002 4099-9003 With 2098-9828 Breakglass Push Institutional Cover kit L!J.IItIt1 Activation of the Simplex 4099-9001 single manual station requires a firm downward pull to activate the alarm switch. Completing the action breaks an internal plastic break-rod (visible below the pull lever, use is optional). The use of a break-rod can be a deterrent to vandalism without interfering with the minimum pull requirements needed for easy activation. The pull lever latches into the alarm position and remains extended out of the housing to provide a visible indication. Double Action Stations (Breakglass) require the operator to strike the front mounted hammer to break the glass and expose the recessed pull lever. The pull lever then operates as a single action station. 5®Simplex UL, ULC Listed; FM, CSFM, and MEA (NYC) Approved* Ih!I*I Individually addressable manual fire alarm stations with: Power and data supplied via MAPNET II or IDNet addressable communications using a single wire pair** Operation that complies with ADA requirements Pull lever that protrudes when alarmed Break-rod supplied (use is optional) Models are available with single or double action (breakglass or push) operation UL listed to Standard 38 Compatible with Simplex: Model Series 4010/4100/4120/4020 fire alarm control panels equipped with either IDNet or MAPNET II communications Model Series 2120 communicating device transponders (CDTs) equipped with MAPNET II communications Compact, sealed construction: NEMA 2 enclosure rating for minimal dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections Tamper resistant reset key lock (keyed same as Simplex fire alarm cabinets) Multiple mounting options: Surface or semi-flush with standard boxes or matching Simplex boxes Flush mount adapter kit Adapters are available for retrofitting to commonly available existing boxes I 11*Ni FUrT1 The Simplex model 4099-9001 addressable station combines the familiar Simplex manual station housing with a compact communication module that is easily installed to satisfy demanding applications. Its integral individual addressable module (JAM) constantly monitors status and communicates changes to the connected control panel via MAPNET II or IDNet communications wiring. -Double Action Stations (Push Type) require that a spring loaded interference plate (marked PUSH) be pushed back to access the pull lever of the single action station. Station reset requires the use of a key to reset the manual station lever and deactivate the alarm switch. (If the break-rod is used, it must be replaced.) * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7150-0026:224 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable, contact Simplex for the latest status. © 2000 Simplex Time Recorder Co. All rights reserved. Station testing is performed by physical activation of the pull lever. Electrical testing can be also performed by unlocking the station housing to activate the alarm switch. MAPNET II and IDNet addressable communications designs are protected by U.S. Patent No. 4796025. S4099-0001-5 8/00 Addressable Manual Station Product Selection Addressable ManualIStations Model Description 4099-9001 Single action 4099-9002 Double action, Breakglass OPE 4099-9003 Double action, Push operation Addressable manual station, red housing with white letters and white pull lever S Accessories Model 2975-9178 Description Surface mount steel box, red Reference Refer to page 3 for dimensions 2975-9022 Cast aluminum surface mount box, red 2099-9813 Semi-flush trim plate for double gang switch box, red Typically for retrofit, refer to page 4 2099-9814 Surface trim plate for Wiremold box V5744-2, red 2099-9819 Flush mount adapter kit, black Refer to page 4 for details 2099-9820 Flush mount adapter kit, beige 2099-9803 Replacement breakglass 2099-9804 Replacement break-rod 2099-9828 Institutional cover kit for field installation on 4099-9001 Wire connections cr termi or in/out •ring, for to 14 A wire UL Listed Temperature Range 32° to 120° F (00_0 C) in d for oper Humidity Range Up to 93% RH at 1000 F (38° F) Housing Color Red with white raised lettering Material Housing and pull lever are Lexan® polycarbonate Pull Lever Color White with red raised lettering Housing Dimensions 5" H x 3 3/4" W x 1" D (127 mm x 95 mm x 25 mm) Single Gang Box Mount 4 Square Box Mount Single gang box, 2 1/2 deep 4" (102 mm) square box, 2 1/8' (54 mm) minimum (64 mm), RACO #500 or equal depth, RACO #231 or equal (supplied by others) (supplied by others) o o / Mount flush or with 1/16" (2 mm) -, - r r] J maximum extension 4 Square box DO NOT RECESS thcover plate p rL FIRE J()tALARI PULL DOWN 7~ [Sirp3ex} ___ - Station I side view Single gang cover plate, 3/4" - -------- (19 mm) extension, RACO #773 or equal (supplied by others) _j Single gang box outline Wall surface ' L J Semi-Flush Mount Side View S Simplex Time Recorder Co. 2 S4099-0001-5 8/00 S S Addressable Manual Stations Surface Mounting Preferred Mounting. For surface mounting of these addressable manual stations, the preferred electrical boxes are shown in the illustration to the right. Additional Mounting Reference. Refer to page 4 for Wiremold box mounting compatibility. 2975-9178 Box 53/16 Hx4Wx23/16 D (132 mm x 102 mm x 56 mm) (ordered separately) Knockouts located top and bottom 2975-9022 Cast Box 5" Hx37/8"Wx23/16D (127 mm x 98 mm x 56 mm) (ordered separately) 0 I II 0 LFIRE1 [ALARM El PULL DOWN Access for 3/4 threaded 5" conduit located top and bottom (127 mm) j [F OSimplex 1(25.4 mm) [4 33/4 (95 mm) 4099 Series Addressable Manual Station Refer to NFPA 72, the National Fire Alarm Code (reference section 5-8), 1 1/4" and all applicable local codes for Field wiring (32 mm) Simplex 2975-9178 box complete requirements for manual (shown for reference) (shown for reference) stations. The following summarizes the basic requirements. Stations shall be located in the normal path of exit and distributed Address setting under in the protected area such that they resealable label (accessible -r_ / are unobstructed and readily with cover open) accessible. 2 5/8" (67 mm) Mounting shall be with the operable part not less than 3 1/2 ft Station cover I (1.1 m) and not more than 4 1/2 ft hinges open for C (1.37 m) above floor level. installation access At least one station shall be / - Switch wiring provided on each floor. Additional (p rewired) stations shall be provided to obtain a travel distance not more than 200 ft (61 m) to the nearest station from any point in the building. When manual station coverage appears limited in any way, additional stations should be installed. Simplex Time Recorder Co. 3 S4099-0001-5 8/00 Addressable Manual Station, Additional Mounting Information For retrofit and new installations, additional compatible mounting boxes and the required adapter plates are shown in the illustration to the right. 2099-9814 Surface trim for Wiremold box 5 1/8 H x 5W (130 mm x 127 mm) Wiremold receptacle box model V5744-2 (supplied by others) S Please note that these addressable manual stations will also install onto single gang Wiremold® box model V5747 but will overlap the box. Wiremold V5747 dimensions are: 4 5/8" H x 27/8"Wx 13/8"D(117mm x73mmx35 mm). 4099-9001 IDNet addressable station LD0WN g Two gang switch box, each U 3" H x2" W x 2 3/4" D (76 mm x 51 mm x 70 mm) (supplied by others) 2099-9813 Semi-flush trim for 2 gang switch box, 6" H x 4 1/2W (152 mm x 114 mm) Addressable Manual Station, Flush Mounting Information Flush mount adapter kit 2099-9819, Black 2099-9820, Beige Hole cutout must be a minimum of 6" H by 5' W (152 mm by 127 mm) (152 - - Wall 43/4(121 mm) surface 63/4" (171 mm) Box must be recessed into wall 1" to 11/8' (25.4 mm to 29 mm) 0 :0 0 4 11/16" (119 mm) square box, 2 1/8' (54 mm) minimum depth (by others) Side View Front View Simplex, the Simplex logo, MAPNET II, and IDNet are either trademarks or registered trademarks of Simplex Time Recorder Co. in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Lexan is a trademark of the General Electric Co. Wiremold is a trademark of the Wiremold Company. S4099-0001-5 8/00 Westminster, Massachusetts 01441-0001 USA 5Sirriplex visit us on the world wide web at www.simplexnet.com All specifications and other information shown were current as of printing and are subject to change without notice. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7150-0026:224 Page 1 of I CATEGORY: Boxes/Pull Stations LISTEE:. Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattem (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4099-9001, -9002, -9003, -9010, .90cffp, *90.1OUP -9011, -9012, *9012Tsp *9012up and -9031C non-coded addressable manual pull stations. Models 4099-9001 and -9010 are single action stations. Models 4099-9002 and -9011 are breakglass stations. Models 4099-9003 and -9012 includes a push bar which must be punched in before being able to grab and pull down the actuating handle. Model 4099-9031C is a double action station. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: 30 VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. OMARKING: Listee's name, model number, electrical rating, and UL label. APPROVAL: Listed as manual pull stations for use with separately listed compatible fire alarm control units. Models are intended for use with listee's Models 4010, 4100,4100U and 4020 control units (CSFM Listing Nos. 7170-0026:226,7165-0026:160 or 7170-0026:187,7170-0026:250 or 7165- 0026:251 and 7165-0026:178). Model 4099-9013C is intended for use with Model 4010 control unit only. For indoor use only. Refer to listee's Installation Instruction Manual for details. *Rev. 09-25-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or . recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 27, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager Duct Sensor Housing, Front View 0 0 g-t 2098-9806 2098-9808 Remote Status/Alarm Indicator and Test Station rwl ii ti r Operation. Simplex® compact air duct smoke sensor housings provide TrueAlarm operation for the detection of smoke in air conditioning or ventilating ducts. Sampling tubes are installed into the duct allowing air to be directed to the smoke sensor mounted in the housing. 1VT Fc1liiITc] 11i.] SJ .Ini riItTI Digital Communication of Analog Sensing. Analog information from the sensor is digitally communicated to the control panel where it is analyzed. Sensor input is stored and tracked as an average value with an alarm or abnormal condition being determined by comparing the sensor's present value against its average. Intelligent Data Evaluation. Monitoring each photoelectric sensor's average value provides a software filtering process that compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. The result is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. ** Please note that smoke detection in air ducts is intended to provide notification of the presence of smoke in the duct. It is not intended to, and will not, replace smoke detection requirements for open areas or other non-duct applications. t TrueAlarrn sensors and MAPNET II and IDNet communications are protected by one or more of the following U.S. Patents: 5,155,468; 5,173,683; 5,543,777; 5,400,014; 5,543,777; 5,710,541; D383,407; D388,352; D392,573; 4,796,025. S4098-0030-3 11/02 5®Simplex TrueAlarm® Analog Sensing UL, ULC Listed; FM, CSFM, Addressable Duct Sensor Housings with TrueAlarm and MEA (NYC) Approved* Photoelectric Sensor; Available with Multiple Relay Control I'Iii* Compact air duct sensor housing with clear cover to monitor for the presence of smoke** Includes factory installed TrueAlarm photoelectric smoke sensor and features: individual sensor information processed by the host control panel to determine sensor status Digital transmission of analog sensor values via MAPNET IT® or IDNetTM, 2-wire communications Programmable sensitivity, consistent accuracy, environmental compensation, status testing, and monitoring of sensor dirt accumulation Model 4098-9755: Basic duct sensor housing (no relay output) powered by MAPNET TI/IDNet communications Model 4098-9756: Duct sensor housing with supervised output for multiple remote relays; requires separate 24 VDC Relay output is under panel control At the panel, relay output can be activated manually or in response to a separate alarm or other input General features: UL listed to Standard 268A Clear cover allows visual inspection Test ports provide functional smoke testing access with cover in place Mounts to rectangular ducts or round ducts; minimum size is 8" (203 mm) square or 18" (457 mm) diameter Magnetic test feature for alarm initiation at housing Optional weatherproof enclosure is available separately (refer to data sheet S4098-0032) Diagnostic LEDs (on interface board): Red Alarm/Trouble LED for sensor status and communications polling display Yellow LED for open or shorted trouble indication of supervised relay control (4098-9756 only) Sampling tubes (ordered separately): Available in multiple lengths to match duct size Installed and serviced with housing in place Remote module options (ordered separately): Remote red status/alarm LED (2098-9808) Remote test station with LED (2098-9806) • . PAM-SD remote relays (refer to page 2 for details) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 3240-0026.241 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. ULC listed models are designated with a C' suffix such as 4098-9755C. Accepted for use - City of New York Department of Buildings - MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. lTrp iM.] IJ .I] rITTTh1hiiu*jJ Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each sensor is determined at the control panel, selectable as the individual application requires. Sensor Status LED. Each sensor housing's red status LED (located on the electrical interface board) pulses to indicate communications with the panel. If the control panel determines that a sensor is in alarm, or that it is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor housing's status LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify any alarmed sensors. (Remote Status/Alarm LEDs track the operation of the sensor housing LED.) IJ I-10, Typically duct sensor applications require less sensitive settings (such as 2.5% per foot obscuration) due to the ducts being a relative dirty environment. However, the standard seven levels of TrueAlarm sensor sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivity is selected and monitored at the fire alarm control panel. IlT7Fiii,1S SI . Individual smoke sensitivity selection Sensitivity monitoring that satisfies NFPA 72 sensitivity testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic, once per minute individual sensor calibration check verifies sensor integrity r lrueAlarm photoelectric sensors use a stable, pulsed • Automatic environmental compensation infrared LED light source and a silicon photodiode • Smoke sensitivity is displayed in percent per foot receiver to provide consistent and accurate low power • Ability to display and print detailed sensor smoke sensing. information in plain English language Relays of model 4098-9756 are under panel control for ON, OFF, or override I IJ! iM.].TI IliTThI Duct Smoke Sensor Housing with Photoelectric Sensor* Model Description Compatibility 4098-9755 Basic duct sensor housing; operating power is supplied by Simplex fire alarm control panel models 4010, 4020, 4100, 4100U, and 4120. Also 2120 CDT if either MAPNET 11 or IDNet communications (no relay output) configured for MAPNET II, TrueAlarm operation ....-... 4098-9756 Duct housing with supervised multiple relay control for up to 15, PAM-SD Relays (ordered separately); requires separate Same as above except relay operation is not 24 VDC fire alarm power and relay end-of-line resistor compatible 2120 CDT Remote LED Indicator and Test Station, Select One if Required Model Description 2098-9808 Red LED status indicator Use single gang box, 2098-9806 Test Station with keyswitch and red LED status indicator 4098-9755 4098-9756 3" H x 2" W x 2" D (76 mm x 51 mm x 51 mm) "TEST" (turning switch to initiates alarm for system testing) Epoxy Encapsulated Remote Relay (wiring is 18 AWG (0.82 mm2) color coded wire leads) ModelDescription * Compatththty — Mountrng Relay; single Form C (10 A @ 120 VAC); refer to pages 3 and PAM 4f0r information; from Air 4098-9756 only; -SD additional relay order separately Locate relays within 3 ft (1 m) of device being connect up to 15 controlled, per Products & Controls Ltd. Section 3-9.2.1 * Each duct housing includes an internally mounted model 4098-9714 TrueAlarm photoelectric sensor and an exhaust tube. A correctly sized sampling tube (ordered per application) is required, refer to chart below. Sampling Tube Selection Chart, Ordered Separately Per Duct Width, Select One Overall Duct Width (305 mm) Tube Required 2098-9796 Suggested Cut Length 1/2 in. (12.7 mm) longer than duct width to 23" (330 mm to 584 mm) 2098-9804 1/2 in. (12.7 mm) longer than duct width 24" to 46" (610 mm to 1168 mm) 2098-9797 2 in. (51 mm) longer than duct width 46" to 71" (1168 mm to 1803 mm) 2098-9798 2 in. (51 mm) longer than duct width 71" to 95" (1803 mm to 2413 mm) 2098-9799 2 in. (51 mm) longer than duct width S4098-0030-3 11/02 ED I91TrIii Tflfl1 PThTIIJ(4it* NOTE: Refer to lnstallaticn Instructions 574-776 for additional detail and maintenance information. ' others O98-714 Smoke sensor, mounted in special interface base (supplied) lul Metal plate with dual holes for 3/4" (19 mm) conduit, plug supplied for unused hole 6-3/4 ri (171 mm ) Sampling tube access hole Yellow LED, relay control trouble indicator (4098-9756 only) Red sensor status LED ofducD_ Wiring terminals Mount as shown (preferred) or with electronics area located to the LEFT or UP ONLY luaptive Tastenina screws (4)1 (iasKetea sensor area 3-3t8" (86 mm) (21 mm) V Test ports (2) provided for measuring airflow and or aerosol injectior LGaskets (supplied) Exhaust tube (supplied) Sampling tube, ordered separately per duct width I Duct wall End View with Duct and Tubes LEict housing [18 Round duct outline' (minimum diameter) J 18" Square duct outline' IIExhEusttub$' H (minimum width) J I •• !• Sampling tube, keyed for proper hole alignm with holes facing into airflow (template is I provided for proper tube installation) I PAM-SD Remote Relay (10 A @ 120 VAC, for use with 4098-9756 only) NOTE: Mount in separate electrical box within 3 ft (1 m) of device being controlled per NFPA 72, Section 3-9.2.1 (38 mm) 1-3/16" (30 mm) 3 S4098-0030-3 11/02 M—Tem MW Exhaust Sensor Damper OK Exhaust -'-LIJ ,,Return Air Do not locate sensor here Return air damper Fresh air Air -'-Supply Do not locate Filter ' Sensor sensor here bank OK Bend or other obstruction \ Return 6 Duct inlet 6 Duct idths widths w minimum : minimum Preferred Duct Sensor Locations: A minimum of six duct widths downstream from bends or inlets to avoid air turbulence. On the downstream side of filters to detect fires in the filters. In return ducts, ahead of mixing areas. Upstream of air humidifier and cooling coil. With accessibility for test and service. For additional information, refer to NFPA 90A, Standardfor the Installation ofAir Conditioning and Ventilating Systems. Locations to Avoid: Where dampers closed for comfort control would interfere with airflow. Next to outside air inlets (unless the intent is to monitor smoke entry from that area). In return air damper branch ducts and mixing areas where airflow may be restricted. Outdoor Applications Note: For outdoor applications, refer to data sheet S4098-0032 for information on weatherproof enclosure 4098-9845. S Specifications LGeneral Air Velocity Range (liner ft/mm) 300 to 4000 ft/mm (91 to 1220 rn/mm) Sensor Sensitivity Range 0.2% to 3.7% per foot of obscuration, selectable at host control panel UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range 32° F to 122° F (0° C to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10% to 95% RH, non-condensing Wiring Connections Terminal blocks, 18 to 12 AWG (0.82 mm2 to 3.31 mm2 ) Housing Color Remote Status/Alàrni LEDand TestStation with Remote Alarm LED Current Black base with clear cover RémoteStatus/Alárm LED 1.2 mA, no impact to alarm current (2098-9808 or 2098-9806) Test Station Keyswitch Current 3.3 mA, no impact to alarm current (2098-9806) Remote Alarm LED and Test Station Distance 250 ft (76 m) maximum Addressable Operation Data Communications MAPNET II or IDNet communications, auto-select, one address per housing; provides operating power to model 4098-9755 LM?d!1,,4098-9756 with Supervised Multiple Relay C I epa use -* Al Power Supply Input Voltage 8-32 VD (24 VD nominal Standby Current 12.4 mA Q 24 VDC I Alarm Current 115 mA @ 24 VDC; add 15 mA additional for each remote PAM-SD relay For use ith PAM-SD relay only, quantity of 15 maximum; distanc f 5 Supervised Remote Relay Control Output 52 m aximu require 10 kQ, 1 Wend f-line re to rPAM SD Relay Output Ratings, Single Form C use with Mo 09 - - - - Coil Current -- 15 mA @24 VDC, up to 15 maximum per relay control output Relay Contacts, Resistive Ratings 17 A @ 28 VDC; 10 A @ 120 VAC; 250 jxA @ 5 VDC Location Distance I 500 ft (152 m) maximum to relay coils; relays must be within 3 ft (1 m) of device being controlled per NFPA 72, Section 3-9.2.1 Tyco, Simplex, the Simplex logo, TrueAlarm, MAPNET II, and IDNet are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). BSirnplex TEPG-US• 91 Technology Drive• Westminster, Massachusetts• 01441-0001 USA S4098-0030-3 11/02 © 2002 TEPG-US (a Tyco company). All rights reserved. All specifications and other information www.tepg.com shown were current as of document revision date and are subject to change without notice. S CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM 0 LISTING SERVICE LISTING No. 3240-0026:241 Page 1 of 1 CATEGORY: Duct Smoke Detector Housing/Base LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441*0001 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 DESIGN: Models 4098-9755, *40989755TSp *4098..9755TTp 4098-9756, *4098..9756TSp *40989756up 4098-9685, 4098-9686, 4098-9687 and 4098-9688 photoelectric type air duct smoke detector units and Model 4098-9841 relay (for Model 4098-9688 only). Unit consists of a listed detector head, base, a sampling and an exhaust tube and an enclosure. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Air Velocity: 300 - 4000 feet/mm INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. WARKING: Listee's name, model number, electrical & air velocity rating, and UL label. APPROVAL: Listed as duct smoke detector units for installation in HVAC systems when used with separately listed compatible fire alarm control units. Refer to listee's Installation Instruction Manual for details. *Rev. 11-06-03 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: APRIL 6, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-1004:101 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Air Products and Controls Inc., 1749 East Highwood, Pontiac, MI 48340 Contact: *Richard Steele (248) 332-3900 *FA)( (248) 332-8807 DESIGN: Models MR-101/C, MR-104/C, MR-201/C, MR-201/CX, MR-204/C, MR-204/CX, PAM-1, PAM-2, PAM-2X, PAM-3, PAM-4, PAM-SD, RIC-i and RIC-2 relay modules. Models MR- 101/C, -201/C and -201ICX may employ suffix -R or -S. Refer to listee's data sheet for detailed product description and operational considerations. INSTALLATION: In accordance with listee's printed installation instruction, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, electrical rating and UL label. APPROVAL: Listed as relay modules for use with separately listed compatible control units. *Rev. 05-28-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 28, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager iSimpIex lrueAlert® Multi-Candela Notification Appliances 10 UL, ULC Listed, Visible Notification Appliances with Synchronized Flash; FM Approved* Non-Addressable, SmartSyncTM Operation Compatible I1ui i* Visible only (VIO) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: UL listed to Standard 1971 Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Strobes provide synchronized flash for use with: 4010 Series and 4100U Series fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control** 4009 IDNetTM NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes . * This product was not approved by CSFM or MEA (NYC) as of document revision date. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. FIRE Wall Mount Strobes FIE J•;I iuuw I.Iuw Ceiling Mount Strobes I Dpscrintinn Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. F-IMMIRMIMMMrTirI During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. K17 iiriuri ii Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A 117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). S4906-0001 4/2004 iii.] miF I-117=- Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. Iiiiir ii 17u1rm Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). Class B SmartSync two-wire control is available from: 4100U and 4010 Fire Alarm Control Panels; 4010 panels require operating software Revision 2.X or higher (refer to data sheet S4010-0001 for details; refer to data sheet S4100-003 I for basic 4 100U information) 4009 IDNet NAC Extender, models 4009-9201 and 4009-9301 (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938, converts separate conventional horn and strobe NAC inputs into a SmartSync NAC output; up to eight SCMs can be synchronized to each other Class A SmartSync two-wire control is available from 4100U NACs and from the 4905-9938 SCM. Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. 11 Multi-Candela Visible Notification Appliances (Strobes) L Model Mounting Housing Color FIRE Lettering Description - 4906-9101 Wall Red White .....'" 4906-9103 White Red Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; 4906-9102 Ceiling Red White SmartSync two-wire control compatible 4906-9104 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt use to cover 1-1/2" (38 mm) 5-3/8" H x 5-1/4" W x 1-5/8" D (136 mm x 133 mm x 41 mm) 4905-9940 White deep surface mounted boxes Total depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) 1 (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter - Model Description 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to 4-7/8" x 3-1/8" x 0.060" D handy box; not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model 1phon - - Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with 2-7 - X 2) in/out 18 AWG (0.82 mm wire leads, rated for 2 A NAC, 4905-9922 Class A requires 10 mA for power (35 mm x 62 mm x 20 mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" x 4-1/8" x 1-1/4" D 4(102mm) square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description - - - - Dimensions 4905-9992 Red cover with white "FIRE" lettering 5-1/8" H x SW x 1-1/2" D 4905-9993 White cover with red "FIRE" lettering For Wall mount strobes (130 mm x 127 mm x 38 mm) 49059961* Wall mount 6-1/16" H x 6-1/16" W x 3-1/8" D Red wire guard with mounting plate, compatible with (154 mm x 154 mm x 79 mm) 49059926* Ceilingmount semi-flush or surface mounted boxes 6-1/8" x 4-3/8" x 2-7/8" deep (156mmx111mmx73mm) * UL listed by Space Age Electronics Inc. S4906-0001 4/2004 C C Strobe Specifications [1 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note I below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Housing Dimensions (with lens) 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Wall Mount Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd Reference RMS Currents 18 DC at other voltages 24VDC 55 mA '469 mA A V26 mA 41 mA 63mA 123 mA 164 mA Housing Dimensions (with lensk 16 _ " 2- Wx a5/8" D (121 mm x 75 mm x 67 tim) 1. ___________ Ceiling Mount Maximum RMS Current Rating Strobe Setting (see Note 2 below) 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC at other voltages 24 VDC 64 mA 102 mA 199 mA 266 mA 49 mA 76 mA 146 mA 195 mA NOTES: 'Regulated 24 VDC' refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting 01 Th Th 0 fl 0 f Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others I - 104 aLs, 1. MEMO: Wiring terminals 1-111101 ' 4! FIR IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r ..Electrical above bottom \ ii r box outline of compatible \ ii boxes NFPA 72 requires 80" (2.03 m) that the entire lens minimum be not less than 80" and not greater than 96" above the finished floor Jr ________ S4906-0001 4/2004 Removable cover (too] required) Transparent housing and lens assembly Intensity selection 110 plug, accessible only from rear of housing; 15 factory setting is 15 cd Strobe intensity viewing slot 3 Ceiling Mount Strobe Installation Reference J Single gang box (Wiremold V57445) 2-1/4" (57 mm) deep, supplied by others o Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) 4905-9910 Adapter Plate, required for 0 0 0 j( surface mount with handy box unless ________ using the 4905-9926 wire guard I'I I .',! mount strobe Optional 4905-9926 wire guard with mounting plate - - - Strobe intensity I viewing slot Intensity selection plug, accessible only from rear of lens: L--housin factory setting is l5cd - Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Box - IjIII OO HPiF FOR 4905-9931 Adapter Plate 0 4905-9961 Optional Wire Guard (shown here for reference only, 4905-9931 Adapter Plate can be used on other mounting options) Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square I box profile, 1-1/2" i (38 mm) deep Optional 4905-9961 Wire Guard Strobe Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides) Tyco, Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Safety Products Westminster• Westminster, MA - 01441-0001 • USA S4906-0001 4/2004 .Simplex www.tycosafetyproducts-usa-wm.com © 2004 Tyco Safety Products Westminster. All rights reserved All specifications and other information shown were current as ofdocument revision date and are sub/ccl to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7125-0026:316 Page 1 of 1 CATEGORY: Fire Alarm Devices for the Hearing Impaired LISTEE: Simplex, 100 Simplex Drive, Westminter, MA 01441-0001 Contact: Paul Mattern (978) 731-8542 Fax (978) 731-8881 DESIGN: Models 4906-9101, -9102, -9103, and -9104 multi-candela, non-addressable, synchronizable strobe lights. Models 4906-9101 and —9103 are for wall mount. Models 4906-9102 and —9104 are for ceiling mount. Synchronizing modules are required for synchronizing strobe lights if the interconnected control unit does not provide NAC synchronization capabilities. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: Electrical: 16-33 VDC Candela: 15, 30, 75, and 110 Cd INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. S APPROVAL: Listed as strobe lights for use with separately listed compatible fire alarm control units. For indoor use only. Refer to listee's Installation Instruction Manual for details. These units can generate a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition. 06-23-04 $o This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or , recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JUNE 30, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager 5®Simplex TrueAlert® Multi-Candela Notification Appliances S UL, ULC Listed; Visible Notification Appliances with Horn and Synchronized FM Approved* Flash; Non-Addressable, SmartSyncTM Operation Compatible S Audible/visible (NV) notification appliances with efficient electronic horn and high output xenon strobe, available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important installation information on page 3) Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: Horns that are controlled separately from strobes on the same two-wire circuit "On-until-silenced" and "on-until-reset" operation on the same two-wire pair Horn control that can be selected to be temporal coded, march time coded, or on continuously Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate Class B (Style Y) operation requires connection to a compatible SmartSync NAC or to SmartSync Control Module (SCM) 4905-9938 Class A (Style Z) operation when connected to the 4905-9938 SCM or with 4100U series fire alarm control panel NACs Wall mount A/Vs features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount AN adapters are available to cover surface mounted electrical boxes and to adapt to Simplex® 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount A/Vs Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing UL listed to Standard 1971 Regulated circuit design ensures consistent flash output and provides controlled inrush current Audible notification appliance (horn): Low current, 24 VDC electronic horn with harmonically rich output sound suitable for either coded or steady operation UL listed to Standard 464 L FIRE. 1iIIj Wall and Ceiling Mount ANs es cri nt i r Multi-Candela TrueAlert A/Vs with horn and synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount AN housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4" square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount AIVs install using standard 4" electrical boxes. Color choice is determined by model number. M171T1 F. During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. * This product was not approved by CSFM or MEA (NYC) as of document revision date. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. ** Simplex two-wire strobe synchronization operation is protected by U.S. patent No. 5,559,492 and SmartSync horn/strobe operation is protected under U.S. Patent No. 6,281,789. S4906-0002 4/2004 IP7 Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A 117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). 1.] iiFI1T1T1 Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these A/Vs are synchronized by the controlling SmartSync operation NAC. Fiiir.vir. TIIf1UT1i SmartSync operation mode allows a two-wire circuit to provide the ability to activate both the horn and strobe on the same NAC and then allow the horn to be silenced while the strobe remains flashing. The horn operates as "on-until-silenced" while the strobe operation is "on-until-reset." F1riK1'AiI.scrnIT11r.1,l1.(1. 4100U and 4010 Fire Alarm Control Panels (refer to data sheet S4010-0001 for details; refer to data sheet S4100-0031 for basic 4100U information) 4009 IDNet NAC Extender (refer to data sheet S4009-0002) SmartSync Control Module (SCM) 4905-9938 (refer to data sheet S4905-0003) S Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. I Multi-Candela A/Vs F Model Mounting 4906-9127 4906-9129 Wall 4906-9128 Ceiling 4906-9130 Housing Color "FIRE" Lettering Red White White Red Red White White Red Description Horn with Multi-Candela Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela; operates with SmartSync two-wire control Wall Mount A/V Adapters L Model - Description - Dimensions - 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2" (38 mm) deep 4905-9940 White surface mounted boxes depth with strobe = 4-3/8" (111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for 8-5/16" x 5-3/4" x 0.060" Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 (200 mm 130 mrnx70 mm) SmartSync Control Module M1odel Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4" x 4-1/8" x 1-1/4" D (102 mm) square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount A/Vs Model Description - - Dimensions - 4905-9992 Red cover with white "FIRE" lettering 5-1/8" H x 5W x 1-1/2" D 4905-9993 White cover with red "FIRE" lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description - - - - - - -- - - Dimensions - 49059961 * Wall mount red wire guard with mounting plate, compatible with semi-flush 6-1/16" H x 6-1/16" W x 3-1/8" D or surface mounted boxes (154 mm x 154 mm x 79 mm) 49059927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2" x 6-1/8" x 3" (216 mm x 156 mm x 76 mm) 49059928* Ceiling Red Adapter Plate, required to mount guard to surface 9" x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 1-1/2" deep surface mounted boxes 4-3/4" x 6-7/8" x 1-1/2" deep, (121 mm x 175 mm x 38 mm) 4905-9916 Red * UL listed by Space Age Electronics Inc 2 S4906-0002 4/2004 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating ULC Listed Rating Regulated 24 VDC; see Note 1 below 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAG Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Environmental; Temperature and Humidity 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2) ; two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Voltage Sound Type (see Note 2) Horn Output Ratings @ 10 ft (3 m) Reverberant Chamber, UL464Test Anechoic Chamber 16 VDC I 24 VDC I 33 VDC Steady I Coded I Steady Coded I Steady I Coded 86 dBA I I 82 dBA I I I 88 dBA 84 dBA I I I 90 dBA I 86 dBA 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Wall Mount Housing Dimensions (with lens) 5-1/8" H x 5W x 2-3/4" D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per Strobe Setting (see Note 3 below) 15 cd 30 cd '75 cd 110 cd ___________ Reference RMS Currents 1 D at other voltages VDC 70 mA %011 mA 60 mA 84 mA 1%4 mA 143 mA 185 mA Ceiling Mount Housing Dimensions (with lens) x 2 5/8 4+4 L" x 6-7/8" W D (121 mm x 175 mm x 67 mm) __ __________ Maximum RMS Current Rating pe''.._._ Strobe Setting (see Note 3 below) 15 cd 30 cd 75 cd cd Reference RMS Currents I8VDC ___ at other voltages 24 VDC 1 81 mA 119 mA 216 mA 283 mA 70 mA 97 mA 167 mA 217 mA NOTES: "Regulated 24 VDC" refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired, changes effective May 1, 2004. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a "fast" setting. Under the same test conditions, coded horn output "peak" sound level readings are typically 4 dBA higher. Currents are with horn on steady. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) I rTfl I FUT1 lT T1De] ie rrn i r1Trn;rnj / cj cjTh Th o Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others ei1z EF Transparent housing and lens assembly Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd Removable cover Strobe intensity IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE Bottom of lens is either even with, or slightly r ...-Electrical above bottom \ box outline of compatible \ hi boxes NFPA 72 requires 80' (2.03 m) that the entire lens minimum be not less than 80 and not greater than 96' above the finished floor I Mounting Holes: 4' square (4) Single gang (2) Double gang (3) 75 Wiring access hole Wiring terminals for SmartSync operation (tool required) viewing slot 3 S4906-0002 4/2004 145 Box Ee Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4" (102 mm) square box, Optional 4905-9928 Adapter Plate, surface mounted box / 1-1/2" (38 mm) minimum depth required for surface mounted electrical box Four mounting clamps included, two each side 0 0 ~~ffCeiling reference fiush mounted box I J -:--• .iI_jj Optional 4905-9915/-9916 Adapter, - - recommended for surface mounted box Wiring terminals are (locatedbehind the housing 11-DI E Optional 4905-9927 Red Wire Guard End View ----------------------------------- I , Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd ---------------------------------------- Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard Surface mount conduit and box shown for reference 4" (102 mm) square box profile, 1-1/2" (38 mm) deep Optional 4905-9961 Wire Guard AN 0 4905-9931 Adapter Plate 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red: 4905-9940, White (conduit knockouts are provided on all four sides) S S Tyco, Simplex, the Simplex logo, IDNet, TrueAlert, and SmartSync are trademarks of Tyco International AG or its affiliates in the U.S. and/or other countries. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). - Tyco Safety Products Westminster• Westminster, MA - 0144 1-0001 USA S4906-0002 4/2004 .Smplex www.tycosafetyproducts-usa-wm.com 02004 7'yco Safety Product Westminster. All rights reserved. All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. S LISTING No. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 7125-0026:317 Page 1 of 1 CATEGORY: LISTEE DESIGN: RATING INSTALLATION MARKING: 0 APPROVAL: Fire Alarm Devices for the Hearing Impaired Simplex, 100 Simplex Drive, Westminter, MA 01441 Contact: Paul Mattern (978) 731-8542 FAX (978) 731-8881 Models 4906-9127, 4906-9129 wall mount and Models 4906-9128 and 4906-9130 ceiling mount multi-candela horn/strobes. Refer to listee's data sheet for detailed product description and operational considerations. Electrical: 16-33 Vdc Candela: 15, 30, 75, ll0cd In accordance with listee's printed installation instructions, applicable codes and ordinances, and in a manner acceptable to the authority having jurisdiction. For indoor use only. Listees name, model number, electrical/candela rating, and UL label. Listed as multi-candela horn/strobes with a signaling appliance suitable for the hearing impaired when used with listee's separately listed fire alarm control units. All models require the use of Model 4905-9938 (CSFM Listing No. 7125-0026:235) sync control module unless the horn/strobes are used with the listee's Model 4010 (CSFM Listing No. 7170-0026:226) or 4100 (CSFM Listing Nos. 7170-0026:250 and 7165-0026:251). Refer to listee's Installation Instruction Manual for details. 07-22-2004 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: JULY 22, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. AREND, Senior Deputy Program Manager Models Available H12/24 H12/24K (weatherproof) Product Overview Meet UL and ADA signaling requirements System Sensor's SpectrAlert wall-mount series horns are intended for primary signal- ing use. SpectrAlert products meet UL1971, UL464, and Americans with Disabilities Lower current draw Act requirements. More devices per loop Lower installed cost Universal mounting plate included Accessory mounting plates available Field-selectable horn tones Electromec han ic al/ 3kHz Temporal 3/Non-temporal 3 High/Low dBA output Synchronizable horns with Sync'Circuit" module Aesthetic design & 9 <~> 0 MFA LISTED APPROVED approved Installation. SpectrAlert products offer installation ease which also lowers the installed cost. By taking up no room in the back box, SpectrAlert strobes and horn/strobes make wiring connections simpler and faster. Each SpectrAlert includes a universal mounting plate for 4" square and single gang back box mounting. Accessory mounting plates are also available for small footprint or surface mount applications. Flexibility. SpectrAlert offers the flexibility to meet a broad range of require- ments. The SpectrAlert horns feature a number of field-selectable/reversible horn tones. Aesthetics. To meet building owner aesthetic requirements, SpectrAlert incorporates a stylish, low profile design. And this aesthetic is consistent across all SpectrAlert wall-mount products. 10.5 1 12 17 20 24 30 Low Tone Electromechanical 3000 HZ Interrupted NA NA NA 75 75 79 NA NA NA 75 79 79 High Tone Electromechanical 3000 HZ Interrupted Low Tone Electromechanical 3000 HZ Interrupted 75 75 79 82 82 82 75 NA 75 NA 79 NA 82 79 85 82 85 85 NA NA NA 82 82 85 High Tone Electromechanical 3000 HZ Interrupted 79 79 85 85 88 88 1 79 82 85 88 88 1 88 10.5 12 1 17 20 24 30 NA NA NA 94 96 98 NA NA NA 94 96 98 94 95 98 100 101 102 94 NA 95 NA 98 NA 100 94 101 96 102 98 NA NA NA 94 96 98 94 95 98 100 101 102 93 95 98 1100 1101 102 Temporal Non-Temporal Engineering Specifications Specifications General Walk Test SpectrAlert horns shall be capable of mounting to a standard 4" x 4"x 11/2" back box or a single gang SpectrAlert horns only work on walk tests" with 2" x 4" x i/" hack box using the universal mounting plate included with each SpectrAlert product. time durations of 4 seconds or greater Also, SpectrAlert products, when used in conjuction with the accessory Sync-Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices Input Terminals 12 to 18 AWG shall have an operating voltage range of 10.7-17 volts. 24-volt rated devices shall have an operating voltage range or 20-30 volts. SpectrAlert products shall have an operating temperature of 32° to 120°F Dimensions and operate from a regulated DC or full wave rectified, unfiltered power supply. Horn with universal mounting plate 5 x 5/e x 1/16 Horn - Horn without mounting plate Horn shall be a System Sensor SpectrAlert Model capable of operating at 12 and 24 volts. 215/16" X 55/16"x 1/ie" Horn shall be listed to UL 464 for fire protective signaling systems. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and Weight a non-temporal continuous pattern. All horn models shall operate on a coded power supply. 7.2 Synchronization Module Mounting Module shall be a System Sensor Sync•Circuit listed to UL 464 and shall be approved for 4,, x 4 11/2 or 2 x 4 x 1/e standard boxes fire protective service. The module shall synchronize SpectrAlert strobes at 1J-Iz and horns at temporal Indoor Operating Temperature 3. Also, the module shall silence the horns on horn/strobe models, while operating the strobes, over a 32°F to 120°F (0°C to 49°C) single pair of wires. The module shall be capable of mounting to a 412/16 x 41t/16'x 21/8" back box and Maximum Humidity shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple 95% as tested per UL464 zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply. Weatherproof Operating Temperature 32°F to 150°F (0°C to 66°C) ULC Canadian Models Current Draw Table —40°C to 66°C Average Current (mA) Voltages 12V Models 24V Models 12 or 24VDC and FWR unfiltered Tone High/Low Temp/ 10.5V 12V 17V 20V 24V 30V Operating voltage range* Volume Non DC FWR DC FWR DC FWR DC FW R DC FWR 12V: 10.5-17V; 24V: 20-30V Electro- High Temp 10 11 10 10 14 14 19 2 25 8 29 26 Operating voltage range* mech. Non 16 10 19 14 25 29 (with Sync-Circuit module, MDL) Low Temp NA NA NA NA NA NA 11 12 13 12V, 1147V; 24V, 20-30V Non NA NA NA NA NA 12 16 17 24 ° These products should be operated within their rated volt- 3000 Hz High Temp 11 13 11 11 16 16 24 26 28 23 37 33 age range; UL does, however, test functional integrity to Interrupt. Non 11 17 11 1 21 14 28 19 34 27 39 35 45 -20% and -1-10% of manufacturer's stated ranges. 0 Low Temp NA NA NA NA NA NA 14 14 17 15 21 19 U.S. Patent Numbers Non NA NA NA NA NA NA 13 18 16 21 22 25 5,593,569; 5,914,665; 6,049,446 Sound Output Guide (dBA) UL Reverberant Room dBA @ volts DC Anechoic Room Peak dBA @ lOft./volts DC SpectrAlert Ordering Information Red White Voltage Candela Avg. mA* @Nom. VDC Avg. mA* @Nom.FWR** Horns H12/24 H12/24K (weatherproof) H12/24W - 12/24 12/24 NA NA 10/25 10/25 10/18 10/18 Canada HC12/24A HCl2/24KA (weatherproof) HC12/24WA - 12/24 12/24 NA NA 10/25 10/25 10/18 10/18 Sync-Circuit MDL MDLW 12/24 NA 10/11 12/15 Module Canada [MDLA MDLWA 12/24 NA 10/11 12/15 Notes: Agency Listings - Indoor models; UL, ULC, FM, CSFM, MEA. Weatherproof models: UL, cSFM strobe only), MEA, ULC. All of these SpectrAlert horns are designed for wall mount only. All weatherproof models must use weatherproof back box model WBB. *Current draws assume horn is set at temp 3, electromechanical tone and high audibility. ** FWR = Full Wave Rectified System Sensor Sales and Service System Sensor Headquarters System Sensor Canada System Sensor in China System Sensor - Far East 3825 Ohio Avenue Ph; 905.812.0767 Ph: 86.29.524.6253 Ph: 85.22.191.9003 St. Charles, IL 60174 Fx: 905.812.0771 Fx; 86.29.524.6259 Fx: 85.22.736.6580 Ph: 800/SENSOR2 System Sensor Europe System Sensor in Singapore System Sensor - Australia Fx: 630/377-6495 Ph: 44.1403.276500 Ph: 65.6273.2230 Ph; 613.54.281.142 Documents-on-Demand Fx: 44.1403.276501 Fx: 65.6273.2610 Fx: 613.54.281.172 800/736.7672 x3 www,systemsensor.com © 2002 System Sensor. The company reserves the right to change product specifications without notice. System Sensor - India Ph: 91.124.637.1770 x.2700 Fx: 91.124.637.3118 A05-0367-000-10/03-#1002 CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE 0 LISTING No. 7135-1209:143 Page 1 of 1 CATEGORY: Audible Devices LISTEE: System Sensor, 3825 Ohio Avenue, St. Charles IL 60174 Contact: *Trish Linhart (630) 377-6674 Fax (630) 377-7245 DESIGN: Models PA400R, PA40013, PA400W, APA-451, H12/24, H12/24W, H12/24K, HC12/24, HC12/24W and HC12/24K sounders. Suffix "W" indicating white color and suffix "K" indicating extended indoor operating temperature range of 320 F to 1500 F and a NEMA 3R enclosure rating. Models PA400R, PA400B and PA400W may have suffix "F" for letter FIRE printed on unit. Models H12/24, H 12/24W, HC12/24, HC12/24K and HC12/24W are not suitable for public mode fire alarm service when used at low volume on 12V control panels. Refer to listee's data sheet for additional detailed product description and operational considerations. RATING: PA Series: 12 or 30 VDC APA Series: 15 - 32 VDC H12/24 or HC 12/24 Series: 10.5 - 30 VDC ON STALLATION: In accordance with listee's printed installation instructions, NFPA 72, applicable codes & ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listees name, model number, electrical rating and UL label. APPROVAL: Listed as audible devices for use with separately listed compatible fire alarm control units. For indoor use only. Series H12/24 and HC12/24 can generate the Temporal Pattern signal. If series APA or PA are required to produce a distinctive three-pulse Temporal Pattern Fire Alarm Evacuation Signal (for total evacuation) in accordance with NFPA 72, 1999 Edition, they must be used with a fire alarm control unit that can generate the temporal pattern signal. Refer to manufacturer's Installation Manual for details. NOTE Formerly 7135-0087:132 *Rev. 06-16-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. Date Issued: MAY 28, 2004 Listing Expires June 30, 2005 Authorized By: DIANE K. A REND, Senior Deputy Program Manager 5$implex TrueAlert® Notification Appliances UL Listed, FM and SmartSyncTM Adapter Module for Non-Addressable CSFM Approved* Notification Appliance Circuits (NACs) Model 4905-9815 I1I!iI*I Converts a SmartSync NAC into separate 24 VDC audible and visible appliance outputs: Power and communications are supplied by the SmartSync operation NAC Up to two SmartSync Adapter Modules can be connected to a SmartSync NAC Operation is compatible with: Simplex® fire alarm control panels providing SmartSync two-wire horn/strobe control SmartSync Control Module (SCM) model 4905-9938 (refer to data sheet S4905-0003 for additional information) Appliance control output features: Operation modes are: visible and audible appliances both on; or visible appliance only - with activation determined by the connected control panel An on-board DC-DC regulator ensures proper S appliance voltage and provides self-resetting overcurrent protection Audible output rated for up to 50 mA Visible output rated for up to 250 mA Wiring to audible and visible appliances is supervised with conventional reverse polarity operation; opens or shorts are reported to the control panel Status diagnostics: A visible status LED will light if a wiring fault is detected by either of the on-board output notification appliance supervision circuits General mechanical features: Mounts in standard 4-11/16" (119 mm) square electrical box Cover plates (required) are available for surface or flush mount, ordered separately Covers provide status LED viewing Screw terminals for wiring connections UL listed to Standard 864 S * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the Californa Health and Safety Code. See CSFM Listing 7300-0026:315 for allowable values and/or conditions concerning material presented in this document. It is subject to re-examination, revision, and possible cancellation. This product was not ULC listed or approved by MEA (NYC) as of document revision date. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Safety Products Westminster. -- Conventional TrueAlert ,' audible appliance non-addressable / / appliances / SmartSync / Adapter .1 I I / Conventional -, PIR visible appliance-,' NAC with SmartSync 2-wire operation Fire alarm control panel providing I SmartSync operation NACs (4100U style shown for reference) SmartSync Adapter Module, Typical One-Line Wiring Reference lntrodtutinn Special Notification Requirements. Standard SmartSync operation notification appliances activate horns and/or strobes in response to commands received from the SmartSync operation control source using a two-wire connection. For applications where appliances other than the standard SmartSync appliances are required, the SmartSync Adapter Module provides a separate audible and visible output controlled by the SmartSync operation control source. Typical applications are for connection to special weather-proof appliances, appliances with particular sound output characteristics (special bells or chimes), or for connection to appliances that are required to satisfy specific aesthetic requirements. Maintains SmartSync operation System Advantages. With the SmartSync Adapter Module, non-SmartSync appliances can be controlled while still benefiting from the SmartSync operation ability to provide separate audible and visible control using a two-wire connection (U.S. Patent No. 6,281,789). S4905-0005-1 6/2003 Compatibility with circuit protectors. When connected to remote appliances (up to 200 ft from the adapter) that exit the building and may be exposed to harsh electrical environments, the notification appliance wiring is compatible with Simplex circuit protectors. Compatible protectors are listed on page 3 and should be connected both where the wiring leaves the building and where it connects to the appliances. Provisions for shielded wire. For applications where notification appliance wiring may be exposed to electrical noise, twisted, shielded wiring is recommended. The adapter wiring terminal block has provisions for connecting the shield(s). TrueAlert Adapter Product Selection _Model Dn 4905-98 15 SmartSync Adapter Module; requires surface or flush mount cover plate 4905-9817 Surface Mount Cover Plate 4905-9818 Flush Mount Cover Plate Select one for each 4905-9815; painted beige TrueAlert Adapter Installation Reference Cover plate depth: 0.35 (9 mm) for surface mounted box 0.24(6 mm) for flush mounted box Status indicating LED Light pipe for LED viewing\ 2 I 0 5-1/4' (133 mm) square 4-11/16" (119 mm) square box, 2" (51 mm) minimum depth; ref. RACO 257 [2-1/8" (54 mm) deep], or equal (supplied by others) SmartSync Adapter Module Assembly SmartSync Adapter Module Detail Mounting holes 4-11/16" for cover plate (4) fl (119 mm) P1 Depth into box = 1-9/32" (33 mm) Terminal block for wiring connections ._ Appliance mode selection switch Holes for connecting to mounting box (4) © DISCONNECT POWER © BEFORE SERVICING ii 5" (127 mm) S4905-0005-1 6/2003 Specifications I I I - Electrical Input Voltage Range 33DCee ote w Input Current Supe so m 85 pA typical 12 mA plus audible and visi ppliance loads (see NAC loading below) Output Voltage Range 32 D on- aWhaelator limits inrush current to appliances at 550 mA Audible Appliance Output Rating 50 mA @ 24 VDC Visible Appliance Output Rating 250 mA @ 24 VDC On-board regulator is in effect when NAC voltage drops below 20 V; increase appliance current rating by 10% to determine NAC current requirements for NAC Loading Impact worst case line voltage. Example: Assume audible appliance is rated 40 mA; Visible appliance (strobe) is rated 180 mA @20 VDC (150 mA @24 VDC) Alarm Current = 12 mA + (1.1) (180 mA + 40 mA) = 254 mA Wiring Reference Appliance Distance from SmartSync Adapter 200 ft maximum (61 m) Supervision Resistor 10 kO, 1/2W; two required, one located at each remote appliance Wiring Connections Screw terminals for 18 to 12 AWG (0.82 mm2 to 3.31 mm2) Compatible Circuit Protection (required when wiring leaves the building for outdoor appliances, mount one at each end of wiring) 2081-9044, Overvoltage Protector, 200 mA maximum 2081-9028, Isolated Loop Circuit Protector, 5 A maximum 2081-9027, Isolated Loop Circuit Protector, 200 mA maximum Mechanical and Environmental Dimensions (adapter mounted in bracket, see page 2 for reference drawing) 4-11/16" H x 5" W x 1-9/32" D (119 mm x 127 mm x 33 mm) Mounting Plate Material Sheet metal, galvanized Temperature Range 32° to 120° F (0° to 49° C) intended for indoor operation Humidity Range 10% to 90% RH non-condensing at 90° F (32° C) NOTES: The SmartSync adapter is required to be connected to a NAC that provides SmartSync two-wire operation. The rated voltage range listed is the absolute operating range. Operation outside of this range may cause permanent damage to the SmartSync adapter. S4905-0005-1 6/2003 S S Tyco, Simplex, the Simplex logo, and TrueAleri are trademarks of Tyco International Services AG or its affiliates in the U.S. and/or other countries. Tyco Safety Products Westminster• Westminster, MA - 01441-0001 • USA S4905-0005-1 6/2003 www.tycosafetyproducts-usa-wm.com 02003 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as ofdocument revision date and are subject to change without notice. CALIFORNIA DEPARTMENT OF FORESTRY & FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL FIRE ENGINEERING - BUILDING MATERIALS LISTING PROGRAM LISTING SERVICE LISTING No. 7300-0026:315 Page 1 of 1 CATEGORY: Misc. Devices/Control Unit Accessories LISTEE: Simplex, 100 Simplex Drive, Westminster, MA 01441-0001 Contact: Paul Mattem (978) 731-8542 *Fax (978) 731-8881 DESIGN: Models 4905-9815 SmartSync Adapter Module and 4905-9816 TrueAlert Adapter Module. Units allow conventional notification appliances to be operated on a SmartSync notification appliance circuit or TrueAlert signal line circuit. The adapters can employ either one audible and one visual appliance or one combination audible/visual unit. Refer to listee's data sheet for detailed product description and operational considerations. RATING: 24VDC INSTALLATION: In accordance with listee's printed installation instructions, applicable codes and ordinances and in a manner acceptable to the authority having jurisdiction. MARKING: Listee's name, model number, electrical rating and UL label. 0 APPROVAL: Listed as control unit accessories for use with Simplex's 4010 and 4100 series fire alarm control units (CSFM Listing No. 7170-0026:226, 7165-0026:160 and 7170-0026:187). I *Rev. 05-13-2003 This listing is based upon technical data submitted by the applicant. CSFM Fire Engineering staff has reviewed the test results and/or other data but does not make an independent verification of any claims. This listing is not an endorsement or recommendation of the item listed. This listing should not be used to verify correct operational requirements or installation criteria. Refer to listee's data sheet, installation instructions and/or other suitable information sources. 0 Date Issued: MAY 10, 2004 Listing Expires June 30, 2005 Authorized By. DIANE K. A REND, Senior Deputy Program Manager tL,CD IF/re & I Security 15implex6rinnelf SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax. (858) 740-0156 www.simplexgrinnell.com APPENDIX ITEM A . B DESCRIPTION BUSINESS LICENSE WARRANTY 9/30/2004 REV.#: 0 PROJECT #: S tqca / Ffre & I Security SimplexGrinnell SirnplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com Contractor License # 802591 * * * Business Information * * * SIMPLEX GRThNELL L P 6952 PRESTON AVE STE A LIVERMORE, CA 94550 Business Phone Number: (925) 273-0100 Entity: Partnership Issue Date: 12/28/2001 Expire Date: 12/31/2005 * * * License Status * * * This license is current and active. All information below should be reviewed. * * * Classifications * * * Clas Description C1O ELECTRICAL EIFIRE PROTECTION CONTRACTOR * * * Certifications * * * Description Ri ASBESTOS - (for bidding purposes only) * * * Bonding Information * * * CONTRACTOR'S BOND: This license filed Contractor's Bond number 81880913 in the amount of $10,000 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 01/01/2004 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL(1): This license filed Bond of Qualifying Individual number 81880915 for RONALD GILBERT MAYLE in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 BOND OF QUALIFYING INDIVIDUAL(2): This license filed Bond of Qualifying Individual number 81880914 for FRANKLIN MICHAEL BROWN in the amount of $7,500 with the bonding company FEDERAL INSURANCE COMPANY. Effective Date: 12/20/2001 * * * Workers Compensation Information * * * This license has workers compensation insurance with the AMERICAN HOME ASSURANCE COMPANY Policy Number: RMWC5898786 Effective Date: 10/01/2004 Expire Date: 10/01/2005 S n lFre i & Security SimplexGrinnell SimplexGrinnell LP 9855 Carroll Canyon Road San Diego, CA 92131 Tele: (858) 740-0100 Fax: (858) 740-0156 www.simplexgrinnell.com SIMPLEXGRINNELL WARRANTY WARRANTY & DAMAGES: SimplexGrinnell hereby warranties for one (1) year from the date of beneficial use or eighteen (18) months from date of delivery to the purchaser to replace, or at its option, to repair any equipment or parts thereof which are found to be defective in material or workmanship. This warranty is made to the purchaser of this equipment and is in lieu of all other warranties, expressed or implied, including any implied warranty of merchantability of fitness for a particular purpose. SimplexGrinnell shall not be liable for any direct, incidental or consequential loss of damage to the purchaser or user of this equipment arising out of the failure of the equipment to operate in excess of the purchase price of said equipment. This warranty is solely limited to the equipment as provided by SimplexGrinnell in this submittal and excludes associated field wiring and/or any equipment to which the submitted equipment may be attached or connected. WARRANTY SERVICE HOURS: 8:00 AM TO 5:00 PM, MONDAY THROUGH FRIDAY, EXCLUDING LOCALLY OBSERVED SIMPLEX HOLIDAYS. - OFF HOURS RESPONSE IS AVAILABLE AT EXTRA COST. 0